+ERV
|
|
|
+ SL, BR, GR & EV SERIES
|
|
|
+
|
|
|
+ SINGLE/MULTI-FAMILY ERV CATALOG
|
|
|
+
|
|
|
+JANUARY 2019
|
|
|
+
|
|
|
+RENEWAIRE.COM | 800.627.4499
|
|
|
+BECAUSE INDOOR
|
|
|
+
|
|
|
+AIR QUALITY MATTERS
|
|
|
+
|
|
|
+As buildings become more airtight due to better application of ERV technologies. Deficient IAQ is a
|
|
|
+construction methodologies, the need for increased serious problem, especially considering:
|
|
|
+and balanced ventilation is critical. Without it, internally u On average, Americans spend 90% of their time indoors
|
|
|
+generated contaminants accumulate and cause deficient u The EPA found that indoor air may be 2-5 times—and
|
|
|
+indoor air quality (IAQ), which leads to significant
|
|
|
+health and cognitive problems for occupants. Industry occasionally greater than 100 times—more polluted
|
|
|
+standards are changing to combat deficient IAQ, and than outdoor air
|
|
|
+codes that adopt these new standards are driving the u The EPA ranks indoor air pollutants as a top-five
|
|
|
+ environmental health risk to occupants
|
|
|
+
|
|
|
+HEALTH PRODUCTIVITY LEARNING
|
|
|
+MAT TERS MAT TERS MAT TERS
|
|
|
+
|
|
|
+ADVERSE EFFECTS ABOUT RENEWAIRE
|
|
|
+
|
|
|
+O F DEFICIENT IAQ For over 30 years, RenewAire has been
|
|
|
+ a pioneer in enhancing IAQ in commercial and
|
|
|
+Deficient IAQ has numerous adverse effects on the residential buildings of every size. This is achieved
|
|
|
+health and cognitive function of building occupants. while maximizing sustainability through our fifth-
|
|
|
+ generation, enthalpic-core, static-plate Energy
|
|
|
+ Health problems: Acute allergies, Recovery Ventilators (ERVs) that optimize energy
|
|
|
+ headaches, coughs, asthma, skin efficiency, lower capital costs via HVAC load
|
|
|
+ irritations and breathing difficulties, reduction and decrease operational expenses
|
|
|
+ as well as chronic illnesses such as by minimizing equipment needs, resulting
|
|
|
+ cancer, liver disease, kidney damage in significant energy savings. Our ERVs are
|
|
|
+ and nervous-system failure. competitively priced, simple to install, easy to use
|
|
|
+ and maintain, have a quick payback and enjoy the
|
|
|
+ Cognitive impairment: Studies by the industry’s best warranty with the lowest claims
|
|
|
+ Harvard School of Public Health and the due to long-term reliability. In 2010, RenewAire
|
|
|
+ Lawrence Berkeley National Laboratory joined the Soler & Palau (S&P) Ventilation Group,
|
|
|
+ found that carbon dioxide (CO )—an providing direct access to the latest in energy-
|
|
|
+ efficient air-moving technologies. For more
|
|
|
+ 2 information, visit: renewaire.com.
|
|
|
+
|
|
|
+ indoor air contaminant—negatively impacted
|
|
|
+ thinking and decision-making at levels
|
|
|
+ commonly found inside homes and buildings.
|
|
|
+ TABLE OF CONTENTS
|
|
|
+
|
|
|
+ TABLE OF
|
|
|
+
|
|
|
+CONTENTS
|
|
|
+
|
|
|
+ABOUT RENEWAIRE 2-3 GR SERIES - Unitary ERV
|
|
|
+SPECIFICATIONS & DIMENSIONS 4-17
|
|
|
+OPTIONS & ACCESSORIES 18-23 MODEL TYPE CFM RANGE PAGE
|
|
|
+CERTIFICATIONS & PERFORMANCE 24-25 GR90 - STANDARD 40-110 CFM 10
|
|
|
+ORDERING & SUPPORT 26-28 Contractor-Grade,
|
|
|
+ Four-Duct Connection
|
|
|
+
|
|
|
+SL SERIES - Unitary ERV
|
|
|
+
|
|
|
+MODEL TYPE CFM RANGE PAGE EV SERIES - Unitary ERV
|
|
|
+SL70H - STANDARD 51-76 CFM* 4-5
|
|
|
+ Consumer-Grade, 51-76 CFM* 6-7 MODEL TYPE CFM RANGE PAGE
|
|
|
+ Four-Duct Connection EV90 - STANDARD 40-110 CFM 11
|
|
|
+ Consumer-Grade, 40-110 CFM 12
|
|
|
+SL70L - STANDARD Consumer-Grade, Four-Duct Connection 50-140 CFM 13
|
|
|
+ Four-Duct Connection 100-200 CFM 14
|
|
|
+ EV90P - STANDARD Consumer-Grade, 100-240 CFM 15
|
|
|
+ Four-Duct Connection 150-300 CFM 16
|
|
|
+*Continuous mode range
|
|
|
+ Consumer-Grade,
|
|
|
+ EV130 - STANDARD Four-Duct Connection
|
|
|
+
|
|
|
+ EV200 - STANDARD Consumer-Grade,
|
|
|
+ Four-Duct Connection
|
|
|
+BR SERIES - Unitary (Two Duct) ERV
|
|
|
+ Consumer-Grade,
|
|
|
+MODEL TYPE CFM RANGE PAGE EV240 - STANDARD Four-Duct Connection
|
|
|
+BR70 - STANDARD Two-Duct Connection 40-70 CFM 8
|
|
|
+BR130 - STANDARD Two-Duct Connection 50-140 CFM 9 EV300 - STANDARD Consumer-Grade,
|
|
|
+ Four-Duct Connection
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 1
|
|
|
+ ABOUT RENEWAIRE
|
|
|
+
|
|
|
+ R E N E WA I R E E R Vs
|
|
|
+
|
|
|
+ ACHIEVE SUSTAINABLE IAQ
|
|
|
+
|
|
|
+ RenewAire is a pioneer in enhancing IAQ while maximizing sustainability through enthalpic-core, static-plate Energy
|
|
|
+ Recovery Ventilators (ERVs) that optimize energy efficiency, lower costs by reducing HVAC loads and therefore
|
|
|
+ reduce environmental footprints. Our ERV technology preconditions incoming air with the otherwise-wasted energy
|
|
|
+ (heat and humidity) of the exhaust air going out—all while the airstreams are kept physically separate as certified by
|
|
|
+ the Air Conditioning, Heating and Refrigeration Institute (AHRI) for zero exhaust air transfer at normal balanced operating
|
|
|
+ conditions. As the pioneer of static-plate core technology in North America, RenewAire is the largest ERV producer in the USA.
|
|
|
+
|
|
|
+ OPTIMIZING OA COOLING SEASON RA OA HEATING SEASON RA
|
|
|
+ ENERGY EFFICIENCY
|
|
|
+ EFFICIENT EFFICIENT
|
|
|
+ Energy efficiency is optimized by preconditioning HEAT & HUMIDITY HEAT & HUMIDITY
|
|
|
+ the outside air coming in with the otherwise-wasted
|
|
|
+ heat and humidity of the exhaust air going out. This TRANSFER TRANSFER
|
|
|
+ exchange of energy moderates temperatures and moisture,
|
|
|
+ decreases HVAC equipment needs, drives operational EA FA EA FA
|
|
|
+ efficiencies and conserves energy.
|
|
|
+
|
|
|
+ REDUCING HVAC LOADS INSIDE OUTSIDE
|
|
|
+ Fresh Air Enters Stale Room Air Exits
|
|
|
+ RenewAire technology reduces HVAC loads during both winter and summer. In turn,
|
|
|
+ HVAC equipment size and needs can be decreased and furnaces and air conditioners Fixed Partition
|
|
|
+ can be smaller. This process ensures efficient operations and keeps both energy use and and Spacer Plates
|
|
|
+ costs low, while at the same time maintaining high-level IAQ.
|
|
|
+ (proprietary resin
|
|
|
+ and composite media) Outside Air
|
|
|
+
|
|
|
+ Stale Room Air
|
|
|
+
|
|
|
+ MINIMIZING ENVIRONMENTAL IMPACT
|
|
|
+
|
|
|
+ The combination of less energy used and HVAC loads being reduced conserves resources. Further, our Madison, WI plant
|
|
|
+ is 100% powered by renewable wind energy, and is one of the few buildings worldwide to be LEED and Green Globes
|
|
|
+ certified, as well as having achieved ENERGY STAR Building status. This commitment to sustainable manufacturing
|
|
|
+ minimizes our overall production and distribution environmental footprint.
|
|
|
+
|
|
|
+2
|
|
|
+ ABOUT RENEWAIRE
|
|
|
+
|
|
|
+WHY RENEWAIRE
|
|
|
+
|
|
|
+IS PREFERRED
|
|
|
+
|
|
|
+ BEST VALUE
|
|
|
+
|
|
|
+ u Priced competitively against other ERV models
|
|
|
+ u Due to competitive pricing and decreased costs, payback is short and ROI is maximized
|
|
|
+ u Contractors can pass these significant savings along to their customers
|
|
|
+
|
|
|
+ RELIABLE OPERATION
|
|
|
+
|
|
|
+ u Built-to-last ERVs have lifespans of 25+ years and operate consistently year-round in every extreme,
|
|
|
+ including frost-free performance in all but the most severe winter climates
|
|
|
+
|
|
|
+ u High-efficiency core operates dry in all conditions, meaning no condensate pans
|
|
|
+ u An industry-leading ten-year warranty for the static-plate core, two-year warranty for commercial
|
|
|
+
|
|
|
+ products and a five-year warranty for residential products
|
|
|
+ u Superior product quality results in paramount reliability and longevity
|
|
|
+
|
|
|
+ HIGHEST-QUALITY INDOOR AIR
|
|
|
+
|
|
|
+ u Stale indoor air is replaced with fresh, conditioned and filtered air from
|
|
|
+ the outside, resulting in Enhanced IAQ by removing harmful contaminants
|
|
|
+
|
|
|
+ u Airstreams do not mix and pollutants are not transferred across partition plates
|
|
|
+ u No biocide used; material does not promote biological growth
|
|
|
+ u Moderated temperatures and humidity maintain a comfortable indoor environment
|
|
|
+
|
|
|
+ OPTIMIZED ENERGY EFFICIENCY
|
|
|
+
|
|
|
+ u Efficient heat and humidity transfer recaptures up to 70-80% of the energy exhausted in the airstream
|
|
|
+ u Energy that’s otherwise wasted by conventional ventilation systems (such as bath fans) is reused,
|
|
|
+
|
|
|
+ thus dramatically reducing monthly operation costs
|
|
|
+ u Energy-efficient operation decreases HVAC loads, which cuts down on energy use and costs
|
|
|
+ u The hotter or colder the climate, the more energy is recovered
|
|
|
+
|
|
|
+ HIGHLY CERTIFIED
|
|
|
+
|
|
|
+ u See individual catalog submittal for certification details:
|
|
|
+ u UL u cUL u ETL u HVI u AHRI
|
|
|
+
|
|
|
+ 3
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+SL 70H Energy Recovery Ventilator
|
|
|
+ EC Motor Standard
|
|
|
+
|
|
|
+INDOOR UNIT NEW SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Unit Dimensions & Weight:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer 27 1/4" L x 20 3/8" W x 9 1/2" H
|
|
|
+ 32 lbs.
|
|
|
+ Continuous Operation Airflow: 51-76 CFM
|
|
|
+ Boost Mode Airflow: 76-94 CFM Max. Shipping Dimensions & Weight (in carton):
|
|
|
+ 29 1/2" L x 22 1/2" W x 11 1/2" H
|
|
|
+ Unit is HVI Tested/Certified per CSA C439 38 lbs.
|
|
|
+ Protocol: Using one L-30 G5 Core
|
|
|
+ Motor(s):
|
|
|
+ Standard Features: Qty. 2, 48V DC motorized impeller packages
|
|
|
+ Unit may be mounted in any orientation
|
|
|
+ Low-voltage circuit for controls Accessories:
|
|
|
+ Hard wiring in electrical box Backdraft damper 6"
|
|
|
+ Dial-A-Flow - balance and airflow adjustment Wall cap 6" - white, brown
|
|
|
+ Variable speed Digital time clock - wall mount (TC7D-W),
|
|
|
+ Boost mode
|
|
|
+ Cross-core differential pressure ports in exterior enclosure (TC7D-E)
|
|
|
+ Gray painted cabinet Carbon dioxide sensor/control - wall mount (CO2-W)
|
|
|
+ IAQ sensor - wall mount (IAQ-W)
|
|
|
+ Controls: Motion occupancy sensor/control -
|
|
|
+ Onboard digital controller with independent
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ variable speeds Percentage timer control (PTL)
|
|
|
+ Percentage timer control with furnace interlock (FM)
|
|
|
+ Filters: Push-button point-of-use controls (PBL), PTL req’d.
|
|
|
+ Total qty. 2, MERV 8, spun-polyester media: MERV 13 filter - OA airstream
|
|
|
+ Wall bracket kit
|
|
|
+ 7 1/2" x 10 1/2" x 1" Electric duct heater - RH series (1-4 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+
|
|
|
+EC MOTOR OPERATING RANGE Note: Indirect Gas-Fired Duct Furnace is not availaSbLle7o0nPtheerSfLo7r0mH.ance Curve
|
|
|
+ Sample Points Depicted in Larger Dots
|
|
|
+ 1.20
|
|
|
+
|
|
|
+ Airflow (CFM) External Static Unit Power 1.00
|
|
|
+ Pressure Consumption
|
|
|
+
|
|
|
+ (Inches Water (Watts)
|
|
|
+ Column)
|
|
|
+
|
|
|
+ 82 0.1 62
|
|
|
+
|
|
|
+ 77 0.2 60 External Static Pressure (in. w.g.) 0.80
|
|
|
+
|
|
|
+Continuous Mode 72 0.3 59 BOOST
|
|
|
+
|
|
|
+ 67 0.4 58 MODE
|
|
|
+
|
|
|
+ 61 Therma0l.5Performance Ra5ti6ngs for SL130 - Ext0r.a60polated from Catalog.xlsx SL130
|
|
|
+
|
|
|
+ 54 0.6 54
|
|
|
+
|
|
|
+ 45 0.7 51 0.40 CONTINUOUS
|
|
|
+
|
|
|
+ 34 0.8 47 MODE SyCsutermve
|
|
|
+
|
|
|
+ 108 0.1 104
|
|
|
+
|
|
|
+ 102 0.2 102 0.20
|
|
|
+
|
|
|
+ 95 0.3 100
|
|
|
+
|
|
|
+Boost Mode 91 0.4 99 0.00
|
|
|
+
|
|
|
+ 89 0.5 97 30 40 50 60 70 80 90 100 110 120
|
|
|
+
|
|
|
+ 85 0.6 96 = Actual tested sample points Airflow (cfm)
|
|
|
+
|
|
|
+ 81 0.7 94
|
|
|
+
|
|
|
+ 76 0.8 92 CORE PERFORMANCE
|
|
|
+
|
|
|
+ 70 0.9 89 Airflow (CFM)
|
|
|
+
|
|
|
+ 61 1.0 85 Effectiveness (%) 30 60 90 120
|
|
|
+
|
|
|
+Note: Watts is for the entire unit. 100%
|
|
|
+Note: Airflow performance includes effect of clean, standard filter
|
|
|
+supplied with unit. 80%
|
|
|
+Note: Refer to CORES for specific operating point electrical data.
|
|
|
+ 60%
|
|
|
+
|
|
|
+ELECTRICAL DATA FLA Min. Max. 40%
|
|
|
+ Watts Volts HZ Phase per Cir. Overcurrent 20%
|
|
|
+ 96 120 60 1 motor Amps Protection
|
|
|
+ 0%
|
|
|
+ 2 10 Device At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ 15 * See performance ratings per CSA C439 on page 25 of RenewAire’s Single/Multi-Family Catalog.
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+4 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ SL70H Energy Recovery Ventilator EC Motor Standard
|
|
|
+
|
|
|
+ 2 1/4" Typ. 27 1/4" Overall 4 3/8" Typ. ABBREVIATIONS
|
|
|
+ 22 7/8" Case EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ Power Outlet Box with 3' of Flexible Conduit RA: Room Air to be exhausted
|
|
|
+ 7/8" Knockouts FA: Fresh Air to inside
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ TOP VIEW Unit may be installed in any
|
|
|
+ orientation.
|
|
|
+ NOTE
|
|
|
+ 1.UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2.SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 8" Nominal Typ. 4 1/8" Typ. 7 5/8" Minimum 9 1/2"
|
|
|
+ 6" Nominal Typ. Service Area Overall
|
|
|
+ (Door can be
|
|
|
+ 9 1/8"
|
|
|
+ removed from Case
|
|
|
+ hinges.)
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 5 22" - 23" Overall EA 10 3/4" Typ. SA 19 7/8" Minimum 18 5/8" 21 1/4" Overall
|
|
|
+ (With Ceiling Brackets) Service Area (With Hanging Brackets)
|
|
|
+ Door
|
|
|
+ 19" Case Swing
|
|
|
+ 20 3/8" Overall
|
|
|
+ OA RA
|
|
|
+ Control 4 1/8" Typ. 2 1/8"
|
|
|
+ Terminals Pressure Ports RIGHT VIEW Minimum
|
|
|
+ (4) Typ.
|
|
|
+ (Hanging Mount Depicted)Latch
|
|
|
+ Clearance
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+ LEFT VIEW FRONT VIEW Can be mounted in any orientation. RA/EA
|
|
|
+ airstream can be switched with OA/FA airstream.
|
|
|
+ (Hard Mount Depicted)
|
|
|
+ MAoIRdFeLl:OSWL70CHONFIGURATION
|
|
|
+ DArvaailwabilne gas Tshyopwen i:nUdinmietnDsioimn deranwisnigo. n
|
|
|
+ Version: DEC18
|
|
|
+
|
|
|
+ SL-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+SL 70L Energy Recovery Ventilator
|
|
|
+ EC Motor Standard
|
|
|
+
|
|
|
+INDOOR UNIT NEW SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Unit Dimensions & Weight:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer 27 1/4" L x 20 3/8" W x 9 1/2" H
|
|
|
+ 32 lbs.
|
|
|
+ Continuous Operation Airflow: 51-76 CFM
|
|
|
+ Boost Mode Airflow: 76-94 CFM Max. Shipping Dimensions & Weight (in carton):
|
|
|
+ 29 1/2" L x 22 1/2" W x 11 1/2" H
|
|
|
+ Unit is HVI Tested/Certified per CSA C439 38 lbs.
|
|
|
+ Protocol: Using one L-30 G5 Core
|
|
|
+ Motor(s):
|
|
|
+ Standard Features: Qty. 2, 48V DC motorized impeller packages
|
|
|
+ Unit may be mounted in any orientation
|
|
|
+ Low-voltage circuit for controls Accessories:
|
|
|
+ Line-cord power supply Backdraft damper 6"
|
|
|
+ Dial-A-Flow - balance and airflow adjustment Wall cap 6" - white, brown
|
|
|
+ Variable speed Digital time clock - wall mount (TC7D-W),
|
|
|
+ Boost mode
|
|
|
+ Cross-core differential pressure ports in exterior enclosure (TC7D-E)
|
|
|
+ Gray painted cabinet Carbon dioxide sensor/control - wall mount (CO2-W)
|
|
|
+ IAQ sensor - wall mount (IAQ-W)
|
|
|
+ Controls: Motion occupancy sensor/control -
|
|
|
+ Onboard digital controller with independent
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ variable speeds Percentage timer control (PTL)
|
|
|
+ Percentage timer control with furnace interlock (FM)
|
|
|
+ Filters: Push-button point-of-use controls (PBL), PTL req’d.
|
|
|
+ Total qty. 2, MERV 8, spun-polyester media: MERV 13 filter - OA airstream
|
|
|
+ Wall bracket kit
|
|
|
+ 7 1/2" x 10 1/2" x 1" Electric duct heater - RH series (1-4 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+
|
|
|
+EC MOTOR OPERATING RANGE Note: Indirect Gas-Fired Duct Furnace is not availaSbLle7o0nPtheerSfLo7r0mL.ance Curve
|
|
|
+ Sample Points Depicted in Larger Dots
|
|
|
+ 1.20
|
|
|
+
|
|
|
+ Airflow (CFM) External Static Unit Power 1.00
|
|
|
+ Pressure Consumption
|
|
|
+
|
|
|
+ (Inches Water (Watts)
|
|
|
+ Column)
|
|
|
+
|
|
|
+ 82 0.1 62
|
|
|
+
|
|
|
+ 77 0.2 60 External Static Pressure (in. w.g.) 0.80
|
|
|
+
|
|
|
+Continuous Mode 72 0.3 59 BOOST
|
|
|
+
|
|
|
+ 67 0.4 58 MODE
|
|
|
+
|
|
|
+ 61 Therma0l.5Performance Ra5ti6ngs for SL130 - Ext0r.a60polated from Catalog.xlsx SL130
|
|
|
+
|
|
|
+ 54 0.6 54
|
|
|
+
|
|
|
+ 45 0.7 51 0.40 CONTINUOUS
|
|
|
+
|
|
|
+ 34 0.8 47 MODE SyCsutermve
|
|
|
+
|
|
|
+ 108 0.1 104
|
|
|
+
|
|
|
+ 102 0.2 102 0.20
|
|
|
+
|
|
|
+ 95 0.3 100
|
|
|
+
|
|
|
+Boost Mode 91 0.4 99 0.00
|
|
|
+
|
|
|
+ 89 0.5 97 30 40 50 60 70 80 90 100 110 120
|
|
|
+
|
|
|
+ 85 0.6 96 = Actual tested sample points Airflow (cfm)
|
|
|
+
|
|
|
+ 81 0.7 94
|
|
|
+
|
|
|
+ 76 0.8 92 CORE PERFORMANCE
|
|
|
+
|
|
|
+ 70 0.9 89 Airflow (CFM)
|
|
|
+
|
|
|
+ 61 1.0 85 Effectiveness (%) 30 60 90 120
|
|
|
+
|
|
|
+Note: Watts is for the entire unit. 100%
|
|
|
+Note: Airflow performance includes effect of clean, standard filter
|
|
|
+supplied with unit. 80%
|
|
|
+Note: Refer to CORES for specific operating point electrical data.
|
|
|
+ 60%
|
|
|
+
|
|
|
+ELECTRICAL DATA FLA Min. Max. 40%
|
|
|
+ Watts Volts HZ Phase per Cir. Overcurrent 20%
|
|
|
+ 96 120 60 1 motor Amps Protection
|
|
|
+ 0%
|
|
|
+ 2 10 Device At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ 15 * See performance ratings per CSA C439 on page 25 of RenewAire’s Single/Multi-Family Catalog.
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+6 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ SL70L Energy Recovery Ventilator EC Motor Standard
|
|
|
+
|
|
|
+ 2 1/4" Typ. 27 1/4" Overall 4 3/8" Typ. ABBREVIATIONS
|
|
|
+ 22 7/8" Case EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ Unit may be installed in any
|
|
|
+ orientation.
|
|
|
+ NOTE
|
|
|
+ 1.UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2.SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ TOP VIEW
|
|
|
+
|
|
|
+ 8" Nominal Typ. 34" Line Cord 4 1/8" Typ. 7 5/8" Minimum 9 1/2"
|
|
|
+ 6" Nominal Typ. Service Area Overall
|
|
|
+ (Door can be
|
|
|
+ EA 9 1/8"
|
|
|
+ removed from Case
|
|
|
+ hinges.)
|
|
|
+
|
|
|
+ 18 7/8"
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 7 22" - 23" Overall SA 19 7/8" Minimum Door 21 1/4" Overall
|
|
|
+ (With Ceiling Brackets) Service Area (With Hanging Brackets)
|
|
|
+ 10 3/4" Typ. Swing
|
|
|
+ 19" Case
|
|
|
+ 20 3/8" Overall OA RA
|
|
|
+
|
|
|
+ Control Pressure Ports 4 1/8" Typ. 2 1/8"
|
|
|
+ Terminals (4) Typ. Minimum
|
|
|
+
|
|
|
+ Latch
|
|
|
+ Clearance
|
|
|
+
|
|
|
+ LEFT VIEW FRONT VIEW RIGHT VIEW
|
|
|
+
|
|
|
+ (Hard Mount Depicted) (Hanging Mount Depicted)
|
|
|
+ AMIRoFLdOeW l: SCL7O0NL FIGURATION
|
|
|
+ AvDailraablwe aisnsghoTwynpined:imUennsiitonDdirmaweinng.sion UNIT MOUNTING & APPLICATION
|
|
|
+ Can be mounted in any orientation. RA/EA
|
|
|
+ Version: DEC18 airstream can be switched with OA/FA airstream.
|
|
|
+
|
|
|
+ SL-SERIES
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+ BR 70 Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+ INDOOR UNIT SPECIFICATIONS
|
|
|
+ Duct Mounted or Thru-the-Wall
|
|
|
+
|
|
|
+ Download specification at: Ventilation Type: Filters:
|
|
|
+ renewaire.com/specifications Static plate, heat and humidity transfer Total qty. 2, MERV 8, spun-polyester media:
|
|
|
+
|
|
|
+ Typical Airflow Range: 40-70 CFM 7 1/2" x 10 1/2" x 1"
|
|
|
+
|
|
|
+ Unit is Tested to CSA C439 Protocol: Unit Dimensions & Weight:
|
|
|
+ Using one L-30 G5 Core 29 3/4" L x 19 1/4" W x 10 3/4" H
|
|
|
+ 38 lbs.
|
|
|
+ Standard Features:
|
|
|
+ White painted cabinet Max. Shipping Dimensions & Weight (in carton):
|
|
|
+ Line-cord power supply 30" L x 22" W x 15" H
|
|
|
+ Built-in control 50 lbs.
|
|
|
+ Unit may be mounted in any orientation
|
|
|
+ Cross-core differential pressure ports Motor(s):
|
|
|
+ Qty. 1, Double-shaft standard motor
|
|
|
+ Control:
|
|
|
+ Built-in proportional runtime control and switched Accessories:
|
|
|
+ Backdraft damper 6"
|
|
|
+ terminals for furnace/AC interconnect Wall cap 6" - white, brown
|
|
|
+ Exterior thru-the-wall installation kit
|
|
|
+ Duct collar kit (two collars)
|
|
|
+ Electric duct heater - RH series (1-11.5 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+
|
|
|
+ Note: Indirect Gas-Fired Duct Furnace is not available on the BR70.
|
|
|
+
|
|
|
+ ELECTRICAL DATA UNIT PERFORMANCE CORE PERFORMANCE
|
|
|
+ HP Volts HZ Phase Input Watts FLA
|
|
|
+ 0.08 120 60 Single 94 @ 69 CFM 1.0 Airflow CFM ESP in H20 Temp EFF% Total EFF%
|
|
|
+ Winter/Summer*
|
|
|
+ UNIT DIMENSIONS
|
|
|
+ 46 0.40 80 75/62
|
|
|
+
|
|
|
+ 59 0.30 77 72/58
|
|
|
+
|
|
|
+ 73 0.20 75 69/54
|
|
|
+
|
|
|
+ 86 0.10 72 66/51
|
|
|
+
|
|
|
+ * See performance ratings per CSA C439 on page 25 of RenewAire’s Single/Multi-Family Catalog.
|
|
|
+
|
|
|
+ AIRFLOW CONFIGURATION
|
|
|
+ Available as shown in dimension drawing.
|
|
|
+
|
|
|
+ UNIT MOUNTING & APPLICATION OA (TW) 36" Line Cord ABBREVIATIONS
|
|
|
+ RA (DH) EA: Exhaust Air to outside
|
|
|
+ Can be mounted in any orientation. If duct-mounted, EA (TW) OA: Outside Air intake
|
|
|
+ airstreams cannot be switched. If mounted with 6" FA (DH) RA: Room Air to be exhausted
|
|
|
+ exterior Thru-the-wall installation kit, the RA/EA Cut Hole in Duct FA: Fresh Air to inside
|
|
|
+ airstreams are switched with the OA/FA airstreams. (Minimum Size) TW: Thru Wall
|
|
|
+ If four ducts are connected using duct collar kit, DH: Duct Hung
|
|
|
+ airstreams may be switched. INSTALLATION ORIENTATION
|
|
|
+ Unit may be installed in any
|
|
|
+ 1 1/8" 2" 17 5/8" orientation.
|
|
|
+ NOTE
|
|
|
+ TOP VIEW 1.UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. PRESSURE PORTS FOR EACH
|
|
|
+ AIR STREAM ARE LOCATED ON DOOR
|
|
|
+ OF UNIT.
|
|
|
+ 3. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 19 1/2" Overall OA (TW) 24V AC Proportional 6" Typ.
|
|
|
+ RA (DH) Control Runtime
|
|
|
+ 18 1/8" Case EA (TW) Terminal Control
|
|
|
+ 3/4" FA (DH)
|
|
|
+ CL 5 1/8"
|
|
|
+ 5/8"
|
|
|
+ 2 1/4" Typ.
|
|
|
+
|
|
|
+ RA (TW) FA (TW) 11" 8" Typ.
|
|
|
+ OA (DH) EA (DH) Overall
|
|
|
+ 10 5/8"
|
|
|
+
|
|
|
+ Case
|
|
|
+
|
|
|
+ CL 4 1/2" CL 5 5/8" 25 1/8" Case CL 6 1/8"
|
|
|
+ SEE NOTE 2
|
|
|
+ 27 1/8" Overall Door 18 1/8" Minimum
|
|
|
+ Swing Service Area
|
|
|
+ 29 5/8" Overall
|
|
|
+ (with Duct Collars)
|
|
|
+
|
|
|
+ LEFT VIEW FRONT VIEW 18 1/8" Minimum
|
|
|
+ Service Area
|
|
|
+
|
|
|
+ RIGHT VIEW
|
|
|
+
|
|
|
+ Specifications may be subject to chanMgeowdiethlo: uBtRn7o0tice.
|
|
|
+ Drawing Type: Unit Dimension
|
|
|
+ RENEWAIRE.COM 1.800.62V7e.4r4s9io9n: JUN18
|
|
|
+8
|
|
|
+BR 130 Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+Duct Mounted or Thru-the-Wall
|
|
|
+ Ventilation Type: Filters: BR-SERIES
|
|
|
+Download specification at: Static plate, heat and humidity transfer Total qty. 2, MERV 8, spun-polyester media:
|
|
|
+renewaire.com/specifications
|
|
|
+ Typical Airflow Range: 50-140 CFM 10 1/2" x 10 1/2" x 1"
|
|
|
+
|
|
|
+ Unit is HVI Tested/Certified per CSA C439 Unit Dimensions & Weight:
|
|
|
+ Protocol: Using one L-50 G5 Core 33 1/2" L x 19 1/4" W x 13 1/2" H
|
|
|
+ 48 lbs.
|
|
|
+ Standard Features:
|
|
|
+ White painted cabinet Max. Shipping Dimensions & Weight (in carton):
|
|
|
+ Line-cord power supply 32" L x 22" W x 18" H
|
|
|
+ Built-in control 60 lbs.
|
|
|
+ Unit may be mounted in any orientation
|
|
|
+ Cross-core differential pressure ports Motor(s):
|
|
|
+ Qty. 1, Double-shaft standard motor
|
|
|
+ Control:
|
|
|
+ Built-in proportional runtime control and switched Accessories:
|
|
|
+ Backdraft damper 6"
|
|
|
+ terminals for furnace/AC interconnect Wall cap 6" - white, brown
|
|
|
+ Exterior thru-the-wall installation kit
|
|
|
+ Duct collar kit (two collars)
|
|
|
+ Electric duct heater - RH series (1-11.5 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+
|
|
|
+ Note: Indirect Gas-Fired Duct Furnace is not available on the BR130.
|
|
|
+
|
|
|
+ELECTRICAL DATA UNIT PERFORMANCE CORE PERFORMANCE
|
|
|
+
|
|
|
+HP Volts HZ Phase Input Watts FLA Airflow CFM ESP in H20 Temp EFF% Total EFF%
|
|
|
+0.1 120 60 Single 121 @ 124 CFM 1.3 52 0.70 82 Winter/Summer*
|
|
|
+
|
|
|
+ 78/65
|
|
|
+
|
|
|
+ 69 0.60 80 75/62
|
|
|
+
|
|
|
+ 94 0.50 76 71/57
|
|
|
+
|
|
|
+ 113 0.40 74 68/53
|
|
|
+
|
|
|
+ 132 0.30 71 65/49
|
|
|
+
|
|
|
+ 141 0.20 70 63/47
|
|
|
+
|
|
|
+ 148 0.10 69 62/46
|
|
|
+
|
|
|
+ * See HVI certification ratings on page 24 of RenewAire’s Single/Multi-Family Catalog.
|
|
|
+
|
|
|
+UNIT DIMENSIONS
|
|
|
+
|
|
|
+AIRFLOW CONFIGURATION 33 1/4" Overall ABBREVIATIONS
|
|
|
+Available as shown in dimension drawing. (With Duct Collars) EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ 30 7/8" Overall 36" Line Cord RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ 28 3/4" Case TW: Thru Wall
|
|
|
+ DH: Duct Hung
|
|
|
+UNIT MOUNTING & APPLICATION OA (TW) INSTALLATION ORIENTATION
|
|
|
+ RA (DH) Unit may be installed in any
|
|
|
+Can be mounted in any orientation. If duct-mounted, orientation.
|
|
|
+airstreams cannot be switched. If mounted with 5 3/4" 2 1/8" EA (TW) NOTE
|
|
|
+exterior Thru-the-wall installation kit, the RA/EA 1 1/8" FA (DH) 1.UNLESS OTHERWISE SPECIFIED,
|
|
|
+airstreams are switched with the OA/FA airstreams. DIMENSIONS ARE ROUNDED TO THE
|
|
|
+If four ducts are connected using duct collar kit, Cut Hole in Duct NEAREST EIGHTH OF AN INCH.
|
|
|
+airstreams may be switched. (Minimum Size) 2. PRESSURE PORTS FOR EACH
|
|
|
+ AIR STREAM ARE LOCATED ON DOOR
|
|
|
+ OF UNIT.
|
|
|
+ 3. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 20 3/8"
|
|
|
+
|
|
|
+ TOP VIEW
|
|
|
+
|
|
|
+ 24V AC Proportional
|
|
|
+ Control Runtime
|
|
|
+ Terminal Control
|
|
|
+
|
|
|
+ CL 5 1/8"
|
|
|
+ 8" Typ. 20 1/8" Overall CL 6 1/8"
|
|
|
+ 6" Typ.
|
|
|
+ 5/8" 18 1/8" Case CL 4 5/8"
|
|
|
+ OA (TW)3/4"
|
|
|
+ RA (DH)
|
|
|
+ EA (TW)RA (TW)FA (TW)
|
|
|
+ FA (DH)OA (DH)EA (DH)
|
|
|
+ 13 3/4"
|
|
|
+ Overall2 1/4" Typ.SEE NOTE 2Door
|
|
|
+ 13 3/8"Swing
|
|
|
+ CaseCL 4 1/2"
|
|
|
+ 18 1/8"
|
|
|
+ Minimum
|
|
|
+ Service Area
|
|
|
+
|
|
|
+ LEFT VIEW FRONT VIEW 18 1/2" Minimum
|
|
|
+ Model: BR130 Service Area
|
|
|
+ Drawing Type: Unit Dimension
|
|
|
+ Version: JUN18 RIGHT VIEW
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 9
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+ GR 90 Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+ INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+ Download specification at: Ventilation Type: Filters:
|
|
|
+ renewaire.com/specifications Static plate, heat and humidity transfer Total qty. 2, MERV 8, spun-polyester media:
|
|
|
+ ELECTRICAL DATA
|
|
|
+ Typical Airflow Range: 40-110 CFM 9 5/8" x 10 1/2" x 1"
|
|
|
+ HP Volts HZ Phase Input Watts FLA
|
|
|
+ 0.03 120 60 Single 46 @ 90 CFM 0.35 Unit is HVI Tested/Certified per CSA C439 Unit Dimensions: & Weight
|
|
|
+ Protocol: Using one L-35 G5 Core 22 1/2" L x 11 3/4" W x 23 3/4" H
|
|
|
+ UNIT DIMENSIONS 36 lbs.
|
|
|
+ AIRFLOW CONFIGURATION Standard Features:
|
|
|
+ Available as shown in dimension drawing. Galvanized cabinet Max. Shipping Dimensions & Weight (in carton):
|
|
|
+ Terminal strip hard wiring in ebox (no line cord) 29" L x 22" W x 15" H
|
|
|
+ Unit may be mounted in any orientation 40 lbs.
|
|
|
+ Cross-core differential pressure ports
|
|
|
+ Motor(s):
|
|
|
+ Control: Qty. 2, Standard motorized impeller blowers
|
|
|
+ Can use any switched line-voltage power supply
|
|
|
+ Accessories:
|
|
|
+ (no low-voltage controls) Backdraft damper 6"
|
|
|
+ Wall cap 6" - white, brown
|
|
|
+ 120V line voltage Honeywell control
|
|
|
+ Electric duct heater - RH series (1-11.5 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+
|
|
|
+ Note: Indirect Gas-Fired Duct Furnace is not available on the GR90.
|
|
|
+
|
|
|
+ UNIT PERFORMANCE CORE PERFORMANCE
|
|
|
+
|
|
|
+ Airflow CFM ESP in H20 Temp EFF% Total EFF%
|
|
|
+ 40 0.60 Winter/Summer*
|
|
|
+
|
|
|
+ 84 74/56
|
|
|
+
|
|
|
+ 58 0.50 80 69/50
|
|
|
+
|
|
|
+ 73 0.40 77 65/46
|
|
|
+
|
|
|
+ 85 0.30 74 62/43
|
|
|
+
|
|
|
+ 98 0.20 71 59/39
|
|
|
+
|
|
|
+ 113 0.10 68 56/34
|
|
|
+
|
|
|
+ * See HVI certification ratings on page 24 of RenewAire’s Single/Multi-Family Catalog.
|
|
|
+
|
|
|
+ UNIT MOUNTING & APPLICATION 12 1/4" Overall ABBREVIATIONS
|
|
|
+ (with Hanging EA: Exhaust Air to outside
|
|
|
+ Can be mounted in any orientation. RA/EA airstream Bracket) OA: Outside Air intake
|
|
|
+ can be switched with OA/FA airstream. RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ 2 1/4" Typ. 22 1/2" INSTALLATION ORIENTATION
|
|
|
+ Overall Unit may be installed in any
|
|
|
+ Power Wiring orientation.
|
|
|
+ Inlet 7/8" 18" Case NOTE
|
|
|
+ 1.UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2.SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 5 7/8" Typ.
|
|
|
+
|
|
|
+ TOP VIEW
|
|
|
+
|
|
|
+ 7/8" Typ. 6 1/4" 10 1/8" Minimum 11 5/8"
|
|
|
+ Typ. Service Area Case
|
|
|
+ (Door can be
|
|
|
+ Formed Pressure Ports
|
|
|
+ Inlet Ring (4) Typ. Removed from
|
|
|
+ Hinges.)
|
|
|
+ 6" Nominal OA
|
|
|
+ Typ. 21 1/4"
|
|
|
+ EA
|
|
|
+ 25 1/2" Overall 21 7/8" Case 8" Nominal RA 22 1/4" Minimum Door
|
|
|
+ (with Hanging bracket) Typ. Service Area Swing
|
|
|
+ 11 3/4" 23 3/4"
|
|
|
+ Typ. Overall
|
|
|
+
|
|
|
+ FA
|
|
|
+
|
|
|
+ 2 5/8" 5 3/4"
|
|
|
+ Typ.
|
|
|
+
|
|
|
+ LEFT VIEW FRONT VIEW RIGHT VIEW
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+ Model: GR90
|
|
|
+ RENEWAIRE.COM 1.800.627DV.er4a4rsw9io9inng: JTUyNp1e8: Unit Dimension
|
|
|
+10
|
|
|
+EV 90 Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Filters: EV & GR-SERIES
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Total qty. 2, MERV 8, spun-polyester media:
|
|
|
+ELECTRICAL DATA
|
|
|
+ Typical Airflow Range: 40-110 CFM 9 5/8" x 10 1/2" x 1"
|
|
|
+ HP Volts HZ Phase Input Watts FLA
|
|
|
+ 0.03 120 60 Single 46 @ 90 CFM 0.35 Unit is HVI Tested/Certified per CSA C439 Unit Dimensions & Weight:
|
|
|
+ Protocol: Using one L-35 G5 Core 22 1/2" L x 11 3/4" W x 23 3/4" H
|
|
|
+UNIT DIMENSIONS 36 lbs.
|
|
|
+ AIRFLOW CONFIGURATION Standard Features:
|
|
|
+ Available as shown in dimension drawing. White painted cabinet Max. Shipping Dimensions & Weight (in carton):
|
|
|
+ UNIT MOUNTING & APPLICATION Line-cord power supply 29" L x 22" W x 15" H
|
|
|
+ Can be mounted in any orientation. RA/EA airstream Low-voltage circuit for controls 40 lbs.
|
|
|
+ can be switched with OA/FA airstream. Unit may be mounted in any orientation
|
|
|
+ Cross-core differential pressure ports Motor(s):
|
|
|
+ Qty. 2, Standard motorized impeller blowers
|
|
|
+ Control:
|
|
|
+ Onboard 24 VAC transformer/relay package Accessories:
|
|
|
+ Backdraft damper 6"
|
|
|
+ with switched dry contacts Wall cap 6" - white, brown
|
|
|
+ Percentage timer control (PTL)
|
|
|
+ Push-button point-of-use controls (PBL), PTL req’d.
|
|
|
+ Percentage timer control with furnace interlock (FM)
|
|
|
+ Electric duct heater - RH series (1-11.5 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+
|
|
|
+ Note: Indirect Gas-Fired Duct Furnace is not available on the EV90.
|
|
|
+
|
|
|
+ UNIT PERFORMANCE CORE PERFORMANCE
|
|
|
+
|
|
|
+ Airflow CFM ESP in H20 Temp EFF% Total EFF%
|
|
|
+ Winter/Summer*
|
|
|
+
|
|
|
+ 40 0.60 84 74/56
|
|
|
+
|
|
|
+ 58 0.50 80 69/50
|
|
|
+
|
|
|
+ 73 0.40 77 65/46
|
|
|
+
|
|
|
+ 85 0.30 74 62/43
|
|
|
+
|
|
|
+ 98 0.20 71 59/39
|
|
|
+
|
|
|
+ 113 0.10 68 56/34
|
|
|
+
|
|
|
+ * See HVI certification ratings on page 24 of RenewAire’s Single/Multi-Family Catalog.
|
|
|
+
|
|
|
+ 2 1/4" Typ. 22 1/2" 12 1/4" ABBREVIATIONS
|
|
|
+ Overall Overall EA: Exhaust Air to outside
|
|
|
+ 24V AC (with Hanging OA: Outside Air intake
|
|
|
+ Control 18" Bracket) RA: Room Air to be exhausted
|
|
|
+ Terminal Case FA: Fresh Air to inside
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ Unit may be installed in any
|
|
|
+ orientation.
|
|
|
+ NOTE
|
|
|
+ 1.UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2.SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ TOP VIEW 5 7/8" Typ.
|
|
|
+
|
|
|
+ 7/8" Typ. 10 1/8" Minimum 11 5/8"
|
|
|
+ Service Area Case
|
|
|
+ (Door can be
|
|
|
+ 34" Line Cord
|
|
|
+ Removed from
|
|
|
+ Formed 6 1/4" Hinges.)
|
|
|
+ Inlet Ring Typ.
|
|
|
+ 21 1/4"
|
|
|
+ 6" Nominal Typ.
|
|
|
+25 1/2" Overall 8" Nominal Typ. OA RA 22 1/4" Minimum Door
|
|
|
+ (with Hanging Bracket) EA Service Area
|
|
|
+ 11 3/4" Swing 23 3/4"
|
|
|
+ 21 7/8" Typ. Overall
|
|
|
+ Case
|
|
|
+ FA
|
|
|
+
|
|
|
+ 2 5/8" Pressure Ports 5 3/4"
|
|
|
+ (4) Typ. Typ.
|
|
|
+
|
|
|
+ LEFT VIEW FRONT VIEW RIGHT VIEW
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+Model: EV90
|
|
|
+Drawing Type: Unit Dimension FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 11
|
|
|
+Version: JUN18
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+ EV 90P Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+ INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+ Download specification at: Ventilation Type: Filters:
|
|
|
+ renewaire.com/specifications Static plate, heat and humidity transfer Total qty. 2, MERV 8, spun-polyester media:
|
|
|
+ ELECTRICAL DATA
|
|
|
+ Typical Airflow Range: 40-110 CFM 21 3/4" x 10 1/2" x 1"
|
|
|
+ HP Volts HZ Phase Input Watts FLA
|
|
|
+ 0.03 120 60 Single 44 @ 90 CFM 0.35 Unit is HVI Tested/Certified per CSA C439 Unit Dimensions & Weight:
|
|
|
+ Protocol: Using one L-100 G5 Core 22 1/2" L x 24" W x 23 3/4" H
|
|
|
+ UNIT DIMENSIONS 51 lbs.
|
|
|
+ AIRFLOW CONFIGURATION Standard Features:
|
|
|
+ Available as shown in dimension drawing. White painted cabinet Max. Shipping Dimensions & Weight (in carton):
|
|
|
+ UNIT MOUNTING & APPLICATION Line-cord power supply 33" L x 22" W x 29" H
|
|
|
+ Can be mounted in any orientation. RA/EA airstream Low-voltage circuit for controls 65 lbs.
|
|
|
+ can be switched with OA/FA airstream. Unit may be mounted in any orientation
|
|
|
+ Cross-core differential pressure ports Motor(s):
|
|
|
+ Qty. 2, Standard motorized impeller blowers
|
|
|
+ Controls:
|
|
|
+ Onboard 24 VAC transformer/relay package Accessories:
|
|
|
+ Backdraft damper 6"
|
|
|
+ with switched dry contacts Wall cap 6" - white, brown
|
|
|
+ Percentage timer control (PTL)
|
|
|
+ Push-button point-of-use controls (PBL), PTL req’d.
|
|
|
+ Percentage timer control with furnace interlock (FM)
|
|
|
+ Electric duct heater - RH series (1-11.5 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+
|
|
|
+ Note: Indirect Gas-Fired Duct Furnace is not available on the EV90P.
|
|
|
+
|
|
|
+ UNIT PERFORMANCE CORE PERFORMANCE
|
|
|
+
|
|
|
+ Airflow CFM ESP in H20 Temp EFF% Total EFF%
|
|
|
+ Winter/Summer*
|
|
|
+
|
|
|
+ 42 0.60 86 83/71
|
|
|
+
|
|
|
+ 56 0.50 85 82/70
|
|
|
+
|
|
|
+ 73 0.40 84 80/68
|
|
|
+
|
|
|
+ 87 0.30 83 79/67
|
|
|
+
|
|
|
+ 99 0.20 82 78/66
|
|
|
+
|
|
|
+ 108 0.10 82 78/65
|
|
|
+
|
|
|
+ * See HVI certification ratings on page 24 of RenewAire’s Single/Multi-Family Catalog.
|
|
|
+
|
|
|
+ 2 1/4" Typ. 22 1/2" ABBREVIATIONS
|
|
|
+ Overall EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ 18" Case RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ 24V AC 11 5/8" INSTALLATION ORIENTATION
|
|
|
+ Control Typ. Unit may be installed in any
|
|
|
+ Terminal orientation.
|
|
|
+ 24 1/4" Overall NOTE
|
|
|
+ (with Hanging 1.UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ Bracket) NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2.SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ TOP VIEW
|
|
|
+
|
|
|
+ 7/8" Typ. 6 1/4" Typ. 22 1/4" Minimum 23 5/8"
|
|
|
+ Service Area Case
|
|
|
+ (Door can be
|
|
|
+ 34" Line Cord
|
|
|
+ Removed from
|
|
|
+ 25 1/2" Overall 8" Nominal Hinges.)
|
|
|
+ (with Hanging Bracket) Typ.
|
|
|
+ Door
|
|
|
+ 21 7/8" 6" Nominal Swing
|
|
|
+ Case Typ.
|
|
|
+
|
|
|
+ OA RA 22 1/4" Minimum 23 3/4" Overall
|
|
|
+ Service Area
|
|
|
+ 11 3/4"
|
|
|
+ Typ.
|
|
|
+
|
|
|
+ EA FA
|
|
|
+
|
|
|
+ 2 5/8" Formed Pressure Ports 5 3/4" Typ.
|
|
|
+ Inlet Ring (4) Typ.
|
|
|
+
|
|
|
+ LEFT VIEW FRONT VIEW RIGHT VIEW
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+ Model: EV90P
|
|
|
+ RENEWAIRE.COM 1.800.62VD7er.a4r4swi9oi9nng: JTUyNp1e8: Unit Dimension
|
|
|
+12
|
|
|
+EV 130 Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS Filters: EV & GR-SERIES
|
|
|
+ Total qty. 2, MERV 8, spun-polyester media:
|
|
|
+Download specification at: Ventilation Type:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer 10 1/2" x 10 1/2" x 1"
|
|
|
+
|
|
|
+ Typical Airflow Range: 50-140 CFM Unit Dimensions & Weight:
|
|
|
+ 33 1/2" L x 13 1/4" W x 20" H
|
|
|
+ Unit is HVI Tested/Certified per CSA C439 48 lbs.
|
|
|
+ Protocol: Using one L-50 G5 Core
|
|
|
+ Max. Shipping Dimensions & Weight (in carton):
|
|
|
+ Standard Features: 32" L x 22" W x 18" H
|
|
|
+ White painted cabinet 60 lbs.
|
|
|
+ Line-cord power supply
|
|
|
+ Low-voltage circuit for controls Motor(s):
|
|
|
+ Unit may be mounted in any orientation Qty. 1, Double-shaft standard motor
|
|
|
+ Cross-core differential pressure ports
|
|
|
+ Accessories:
|
|
|
+ Controls: Backdraft damper 6"
|
|
|
+ Onboard 24 VAC transformer/relay package Wall cap 6" - white, brown
|
|
|
+ Percentage timer control (PTL)
|
|
|
+ with switched dry contacts Push-button point-of-use controls (PBL), PTL req’d.
|
|
|
+ Percentage timer control with furnace interlock (FM)
|
|
|
+ Electric duct heater - RH series (1-11.5 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+
|
|
|
+ Note: Indirect Gas-Fired Duct Furnace is not available on the EV130.
|
|
|
+
|
|
|
+ELECTRICAL DATA UNIT PERFORMANCE CORE PERFORMANCE
|
|
|
+ HP Volts HZ Phase Input Watts FLA
|
|
|
+ 0.1 120 60 Single 102 @ 130 CFM 1.3 Airflow CFM ESP in H20 Temp EFF% Total EFF%
|
|
|
+ 0.60 Winter/Summer*
|
|
|
+ 79 0.50
|
|
|
+ 104 0.40 78 73/60
|
|
|
+ 126 0.30
|
|
|
+ 137 0.20 75 69/55
|
|
|
+ 153 0.10
|
|
|
+ 165 72 66/50
|
|
|
+
|
|
|
+ 71 64/48
|
|
|
+
|
|
|
+ 68 61/45
|
|
|
+
|
|
|
+ 67 59/43
|
|
|
+
|
|
|
+UNIT DIMENSIONS * See HVI certification ratings on page 24 of RenewAire’s Single/Multi-Family Catalog.
|
|
|
+
|
|
|
+AIRFLOW CONFIGURATION
|
|
|
+Available as shown in dimension drawing.
|
|
|
+
|
|
|
+UNIT MOUNTING & APPLICATION 33 1/4" Overall 4 1/8" Typ. ABBREVIATIONS
|
|
|
+Can be mounted in any orientation. RA/EA airstream 28 3/4" Case EA: Exhaust Air to outside
|
|
|
+can be switched with OA/FA airstream. OA: Outside Air intake
|
|
|
+ RA: Room Air to be exhausted
|
|
|
+ 2 1/4" Typ. FA: Fresh Air to inside
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ 6 3/8" Unit may be installed in any
|
|
|
+ orientation.
|
|
|
+ NOTE
|
|
|
+ 1.UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2.SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 13 1/2" Overall 31" Typ.
|
|
|
+
|
|
|
+ 6" Typ. TOP VIEW 6" Typ. 11 1/4" Minimum 12 7/8"
|
|
|
+ Service Area Case
|
|
|
+ 34" Line Cord (Door can be
|
|
|
+ 7/8" 8"
|
|
|
+ Nominal Removed from
|
|
|
+ Typ. Hinges.)
|
|
|
+
|
|
|
+ 21 3/4" Overall 18 1/8" OA EA 18 1/2" 20" Overall
|
|
|
+ (with Hanging Case Minimum
|
|
|
+ RA 9" Service Area Door
|
|
|
+ Bracket)
|
|
|
+ FA Swing
|
|
|
+
|
|
|
+ 6" Pressure Ports 8 1/8" 17 1/2"
|
|
|
+ Nominal (4) Typ. 24V AC
|
|
|
+ Typ.2 5/8" Control
|
|
|
+ FRONT VIEW Terminal
|
|
|
+ LEFT VIEW RIGHT VIEW
|
|
|
+
|
|
|
+ Model: EV130 Specifications may be subject to change without notice.
|
|
|
+ Drawing Type: Unit Dimension
|
|
|
+ Version: JUN18 FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 13
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+ EV 200 Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+ INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+ Download specification at: Ventilation Type: Unit Dimensions & Weight:
|
|
|
+ renewaire.com/specifications Static plate, heat and humidity transfer 33 1/2" L x 24" W x 20" H
|
|
|
+ 68 lbs.
|
|
|
+ Typical Airflow Range: 100-200 CFM
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet):
|
|
|
+ Unit is HVI Tested/Certified per CSA C439 34" L x 44" W x 34" H
|
|
|
+ Protocol: Using one L-100 G5 Core 110 lbs.
|
|
|
+
|
|
|
+ Standard Features: Motor(s):
|
|
|
+ White painted cabinet Qty. 1, Double-shaft standard motor
|
|
|
+ Line-cord power supply
|
|
|
+ Low-voltage circuit for controls Accessories:
|
|
|
+ Unit may be mounted in any orientation Backdraft damper 6", 8"
|
|
|
+ Cross-core differential pressure ports Wall cap 6" - white, brown
|
|
|
+ Wall cap 8" - taupe vinyl, galvanized,
|
|
|
+ Controls:
|
|
|
+ Onboard 24 VAC transformer/relay package paintable galvanneal
|
|
|
+ Louver with 8" round duct connection -
|
|
|
+ with switched dry contacts
|
|
|
+ 12" (W) x 8" (H)
|
|
|
+ Filters: Percentage timer control (PTL)
|
|
|
+ Total qty. 2, MERV 8, spun-polyester media: Push-button point-of-use controls (PBL), PTL req’d.
|
|
|
+ Percentage timer control with furnace interlock (FM)
|
|
|
+ 10 1/2" x 21 3/4" x 1" Electric duct heater - RH series (1-11.5 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+
|
|
|
+ Note: Indirect Gas-Fired Duct Furnace is not available on the EV200.
|
|
|
+
|
|
|
+ ELECTRICAL DATA UNIT PERFORMANCE CORE PERFORMANCE
|
|
|
+ HP Volts HZ Phase Input Watts FLA
|
|
|
+ 0.1 120 60 Single 157 @ 181 CFM 1.5 Airflow CFM ESP in H20 Temp EFF% Total EFF%
|
|
|
+ Winter/Summer*
|
|
|
+ UNIT DIMENSIONS
|
|
|
+ AIRFLOW CONFIGURATION 122 0.70 81 77/64
|
|
|
+ Available as shown in dimension drawing.
|
|
|
+ UNIT MOUNTING & APPLICATION 149 0.60 79 75/61
|
|
|
+ Can be mounted in any orientation. RA/EA airstream
|
|
|
+ can be switched with OA/FA airstream. 168 0.50 78 73/59
|
|
|
+
|
|
|
+ 176 0.40 78 72/59
|
|
|
+
|
|
|
+ 186 0.30 77 72/58
|
|
|
+
|
|
|
+ 192 0.20 77 71/57
|
|
|
+
|
|
|
+ 207 0.10 76 70/56
|
|
|
+
|
|
|
+ * See HVI certification ratings on page 24 of RenewAire’s Single/Multi-Family Catalog.
|
|
|
+
|
|
|
+ 2 1/4" Typ. 33 1/4" Overall ABBREVIATIONS
|
|
|
+ 28 3/4" Case EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ 24 3/8" Overall 11 7/8" RA: Room Air to be exhausted
|
|
|
+ (with Hanging Typ. FA: Fresh Air to inside
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ Bracket) Unit may be installed in any
|
|
|
+ orientation.
|
|
|
+ NOTE
|
|
|
+ 1.UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2.SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 21 3/4" Overall TOP VIEW
|
|
|
+ (with Hanging Bracket)
|
|
|
+ 6" Nominal 5 1/2" 34" Line Cord 6" 22 1/4" Minimum 23 7/8" Case
|
|
|
+ 7/8" Typ. Typ. Typ. Typ. Service Area
|
|
|
+ (Door can be
|
|
|
+
|
|
|
+ Removed from
|
|
|
+ Hinges.)
|
|
|
+
|
|
|
+ 18 1/8" OA EA 18 1/2" 20" Overall
|
|
|
+ Case Minimum
|
|
|
+ 9" Service Area Door
|
|
|
+ Swing
|
|
|
+ RA FA
|
|
|
+ 24V AC
|
|
|
+ 8" Nominal Pressure Ports 8 1/8" Control
|
|
|
+ Typ. (4) Typ. Terminal
|
|
|
+
|
|
|
+ 2 5/8" RIGHT VIEW
|
|
|
+
|
|
|
+ LEFT VIEW FRONT VIEW
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+14 RENEWAIRE.COM 1.800.627M.4o4d99el: EV200
|
|
|
+
|
|
|
+ Drawing Type: Unit Dimension
|
|
|
+ Version: JUN18
|
|
|
+EV 240 Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Unit Dimensions & Weight: EV & GR-SERIES
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer 33 1/2" L x 24" W x 20" H
|
|
|
+ 70 lbs.
|
|
|
+ Typical Airflow Range: 100-240 CFM
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet):
|
|
|
+ Unit is HVI Tested/Certified per CSA C439 34" L x 44" W x 34" H
|
|
|
+ Protocol: Using one L-100 G5 Core 112 lbs.
|
|
|
+
|
|
|
+ Standard Features: Motor(s):
|
|
|
+ White painted cabinet Qty. 1, Double-shaft standard motor
|
|
|
+ Line-cord power supply
|
|
|
+ Low-voltage circuit for controls Accessories:
|
|
|
+ Unit may be mounted in any orientation Backdraft damper 6", 8"
|
|
|
+ Cross-core differential pressure ports Wall cap 6" - white, brown
|
|
|
+ Wall cap 8" - taupe vinyl, galvanized,
|
|
|
+ Controls:
|
|
|
+ Onboard 24 VAC transformer/relay package paintable galvanneal
|
|
|
+ Louver with 8" round duct connection -
|
|
|
+ with switched dry contacts
|
|
|
+ 12" (W) x 8" (H)
|
|
|
+ Filters: Percentage timer control (PTL)
|
|
|
+ Total qty. 2, MERV 8, spun-polyester media: Push-button point-of-use controls (PBL), PTL req’d.
|
|
|
+ Percentage timer control with furnace interlock (FM)
|
|
|
+ 10 1/2" x 21 3/4" x 1" Electric duct heater - RH series (1-11.5 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+
|
|
|
+ Note: Indirect Gas-Fired Duct Furnace is not available on the EV240.
|
|
|
+
|
|
|
+ELECTRICAL DATA UNIT PERFORMANCE CORE PERFORMANCE
|
|
|
+ HP Volts HZ Phase Input Watts FLA
|
|
|
+ 0.2 120 60 Single 216 @ 236 CFM 3.3 Airflow CFM ESP in H20 Temp EFF% Total EFF%
|
|
|
+ Winter/Summer*
|
|
|
+UNIT DIMENSIONS
|
|
|
+ AIRFLOW CONFIGURATION 170 0.80 78 72/59
|
|
|
+ Available as shown in dimension drawing.
|
|
|
+ UNIT MOUNTING & APPLICATION 195 0.70 76 70/56
|
|
|
+ Can be mounted in any orientation. RA/EA airstream
|
|
|
+ can be switched with OA/FA airstream. 214 0.60 75 69/54
|
|
|
+
|
|
|
+ 229 0.50 74 67/53
|
|
|
+
|
|
|
+ 242 0.40 73 67/53
|
|
|
+
|
|
|
+ 250 0.30 73 66/52
|
|
|
+
|
|
|
+ 256 0.20 73 65/51
|
|
|
+
|
|
|
+ 265 0.10 72 64/50
|
|
|
+
|
|
|
+ * See HVI certification ratings on page 24 of RenewAire’s Single/Multi-Family Catalog.
|
|
|
+
|
|
|
+ 2 1/4" Typ. 33 1/4" Overall ABBREVIATIONS
|
|
|
+ 2 1/4" Typ. 28 3/4" Case EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ 33 1/4" Overall RA: Room Air to be exhausted
|
|
|
+ 28 3/4" Case FAAB:BFRrEeVshIAATIiOr tNoSinside
|
|
|
+ IUFoROENAAAnrAiSe:i::tT:FnERAmOrxtoeLahauLostaAhtyimosuTiAbdnIsOAtei.erAiNrtiAnoitrOoisrtitnoaiRbnsIlietolEdeaNuedektTexsAiinhdTaeIaOunsNyted
|
|
|
+ 24 3/8" 2O4v3er/8al"lOverall 11 7/8" 11 7/8" D1NoUINN.nrOEIUiMSeiAtNTTnEAERmLtNEELaaLSSStATIySiOoTEObnINIOGe.TSHNHiAnETOsRRHtWEaROIlRlEIeSFONEdATUSAiNnNPTEDIaINOCEnCNIDyFHIET.DO, THE
|
|
|
+ (with H (anwigtihngHanging Typ. Typ. D1N2TO..OISUMPNCTEEELHNCEASSIFISNOICOGNATESTHIWAOERRINTWEHSROIMSOEUAUTSYNPNEDBOCEETIDSFICUIETEBDO.J,ETCHTE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ Bracket)Bracket)
|
|
|
+ 2.SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ TOP VIEW
|
|
|
+
|
|
|
+ (with H (anwigtihngHaBrnagicnkget)Bracket) TOP VIEW
|
|
|
+
|
|
|
+ 21 3/4" 2O1v3er/4al"lOverall Typ. 5 1/2" 22 1/4" Minimum
|
|
|
+ Typ. Service Area
|
|
|
+ Typ.7/8" 6" Nominal 34" Line Cord 5 5/8" 5 5/8" (Door can be
|
|
|
+ Typ.
|
|
|
+ 5 1/2" 2R2e1m/4o"vMedinifmroumm
|
|
|
+ 18Ca1s/e8"7/8" 6" Nominal OA Typ. 34" Line Cord EA 18 1/2" 18 1/2" SerHviincgeeAs.r)ea 20" Over20al"lOverall
|
|
|
+ MinimumMinimum (Door can be 23 7/8" Case
|
|
|
+ ServiceSAerreviace Area
|
|
|
+ Removed from
|
|
|
+ Hinges.)
|
|
|
+
|
|
|
+ Typ. 9" Door 23 7/8" Case
|
|
|
+ Swing
|
|
|
+ ORAA EFA
|
|
|
+ 18 1/8"
|
|
|
+ Case 9" 8 3/8" 8 3/8" Door
|
|
|
+ Swing
|
|
|
+ 8" Nominal RPAressur(e4)PoTyrtps. 6" FA 24V AC
|
|
|
+ 5/8" Typ. Control
|
|
|
+ Terminal
|
|
|
+ 2 8" Nominal Pressure Ports FRONT VIEW 24V AC
|
|
|
+ (HAN(4G) TINypG. BRACKET REMOVED RIGHT VTCeIoErmWntirnoal l
|
|
|
+ 2 5/8" LEFT VIETWyp. 6"
|
|
|
+
|
|
|
+ FOR CLARITY)
|
|
|
+
|
|
|
+ FRONT VIEW Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+ LEFT VIEW (HANGING BRACKET REMOVED FOR CLARITY) RIGHT VIEW
|
|
|
+Model: EV240
|
|
|
+Drawing Type: Unit Dimension FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 15
|
|
|
+Version: JUN18
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+ EV 300 Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+ INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+ Download specification at: Ventilation Type: Unit Dimensions & Weight:
|
|
|
+ renewaire.com/specifications Static plate, heat and humidity transfer 33 3/4" L x 24" W x 20" H
|
|
|
+ 72 lbs.
|
|
|
+ Typical Airflow Range: 150-300 CFM
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet):
|
|
|
+ Unit is HVI Tested/Certified per CSA C439 34" L x 44" W x 34" H
|
|
|
+ Protocol: Using one L-100 G5 Core 115 lbs.
|
|
|
+
|
|
|
+ Standard Features: Motor(s):
|
|
|
+ White painted cabinet Qty. 1, Double-shaft standard motor
|
|
|
+ Line-cord power supply
|
|
|
+ Low-voltage circuit for controls Accessories:
|
|
|
+ Unit may be mounted in any orientation Backdraft damper 8"
|
|
|
+ Cross-core differential pressure ports Wall cap 8" - taupe vinyl, galvanized,
|
|
|
+
|
|
|
+ Controls: paintable galvanneal
|
|
|
+ Onboard 24 VAC transformer/relay package Louver with 8" round duct connection -
|
|
|
+
|
|
|
+ with switched dry contacts 12" (W) x 8" (H)
|
|
|
+ Percentage timer control (PTL)
|
|
|
+ Filters: Push-button point-of-use controls (PBL), PTL req’d.
|
|
|
+ Total qty. 2, MERV 8, spun-polyester media: Percentage timer control with furnace interlock (FM)
|
|
|
+ Electric duct heater - RH series (1-11.5 kW);
|
|
|
+ 10 1/2" x 21 3/4" x 1"
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+
|
|
|
+ Note: Indirect Gas-Fired Duct Furnace is not available on the EV300.
|
|
|
+
|
|
|
+ ELECTRICAL DATA UNIT PERFORMANCE CORE PERFORMANCE
|
|
|
+ HP Volts HZ Phase Input Watts FLA
|
|
|
+ 0.2 120 60 Single 315 @ 297 CFM 3.3 Airflow CFM ESP in H20 Temp EFF% Total EFF%
|
|
|
+ 1.0 Winter/Summer*
|
|
|
+ 170 0.9
|
|
|
+ 191 0.8 78 73/59
|
|
|
+ 215 0.7
|
|
|
+ 256 0.6 77 71/57
|
|
|
+ 277 0.5
|
|
|
+ 295 0.4 75 69/55
|
|
|
+ 311
|
|
|
+ 73 66/51
|
|
|
+
|
|
|
+ 71 65/49
|
|
|
+
|
|
|
+ 70 63/47
|
|
|
+
|
|
|
+ 69 62/46
|
|
|
+
|
|
|
+ * See HVI certification ratings on page 24 of RenewAire’s Single/Multi-Family Catalog.
|
|
|
+
|
|
|
+ UNIT DIMENSIONS
|
|
|
+
|
|
|
+ AIRFLOW CONFIGURATION ABBREVIATIONS
|
|
|
+ Available as shown in dimension drawing. EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ UNIT MOUNTING & APPLICATION 2 1/4" Typ. 33 1/4" Overall RA: Room Air to be exhausted
|
|
|
+ 28 3/4" Case FA: Fresh Air to inside
|
|
|
+ Can be mounted in any orientation. RA/EA airstream INSTALLATION ORIENTATION
|
|
|
+ can be switched with OA/FA airstream. 24 3/8" Overall 9 3/4" Unit may be installed in any
|
|
|
+ (with Hanging Typ. orientation.
|
|
|
+ NOTE
|
|
|
+ Bracket) 1.UNLESS OTHERWISE SPECIFIED,
|
|
|
+ 10" DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ Typ. NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2.SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 21 3/4" Overall TOP VIEW
|
|
|
+ (with Hanging Bracket)
|
|
|
+ 5 3/8" 34" Line Cord 5 1/2" 22 1/4" Minimum 23 7/8" Case
|
|
|
+ 7/8" Typ. Service Area
|
|
|
+ (Door can be
|
|
|
+
|
|
|
+ Removed from
|
|
|
+ Hinges.)
|
|
|
+
|
|
|
+ 18 1/8" OA 9 1/4" EA 18 1/2" 20"
|
|
|
+ Case Minimum Overall
|
|
|
+ Service Area Door
|
|
|
+
|
|
|
+ RA FA Swing
|
|
|
+
|
|
|
+ To Fit Pressure Ports 9 1/8" 24V AC
|
|
|
+ 8" Duct (4) Typ. Control
|
|
|
+ 2 5/8" Typ. Terminal
|
|
|
+
|
|
|
+ LEFT VIEW FRONT VIEW RIGHT VIEW
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+16 RENEWAIRE.COM 1.800.6MD2ro7a.dw4e4in9l:g9EVTy3p0e0: Unit Dimension
|
|
|
+
|
|
|
+ Version: JUN18
|
|
|
+APPLICATIONS
|
|
|
+
|
|
|
+BR-series Common Installation Approaches (BR70 and BR130)
|
|
|
+
|
|
|
+Bottom-Hung Lengthwise Bottom-Hung Crosswise Side-Hung Return Drop Hung
|
|
|
+
|
|
|
+www.renewaire.com (800) 627- 4499 support@renewaire.com www.renewaire.com (800) 627- 4499 support@renewaire.com
|
|
|
+
|
|
|
+EV-series Common Installation Approaches (EV130, EV200, EV240, and EV300) www.renewaire.com (800)627-4499
|
|
|
+ support@renewaire.com
|
|
|
+
|
|
|
+ www.renewaire.com (800) 627- 4499 support@renewaire.com
|
|
|
+
|
|
|
+Separate Room Air Pick-up - Separate Air and Fresh Air Supply
|
|
|
+Fresh Air to Furnace Return Air Trunkline
|
|
|
+
|
|
|
+Note: ERV blower may be operated separate from furnace blower. Note: ERV blower may be operated separate from furnace blower.
|
|
|
+ www.renewaire.com (800) 627- 4499 support@renewaire.com
|
|
|
+
|
|
|
+Furnace Return Air Back into Return Air Furnace Return Air Back into Supply Air
|
|
|
+
|
|
|
+www.renewaire.com (800) 627- 4499 support@renewaire.com
|
|
|
+
|
|
|
+Note: The furnace blower must be operated any time the ERV is operated. Use furnace Note: ERV blower may be operated separate from furnace blower.
|
|
|
+fan “on” continuous low speed or optional FM control to cycle furnace fan on ERV.
|
|
|
+
|
|
|
+EV-series Common Installation Approaches (EV90 and EV90P)
|
|
|
+
|
|
|
+ www.renewaire.com (800) 627- 4499 support@renewaire.com
|
|
|
+
|
|
|
+ support@renewaire.com EA Exhaust Air
|
|
|
+Furnace Return Air Back into Return Air www.renewaire.com (800) 627- 4499
|
|
|
+
|
|
|
+ OA Outside Air
|
|
|
+
|
|
|
+ RA Room Air
|
|
|
+
|
|
|
+ SA Supply Air
|
|
|
+
|
|
|
+ FA Fresh Air
|
|
|
+
|
|
|
+Note: The furnace blower must be operated any time the ERV is operated. Use furnace
|
|
|
+
|
|
|
+fan “on” continuous low speed or optional FM control to cycle furnace fan on ERV.
|
|
|
+
|
|
|
+www.renewaire.com (800) 627- 4499 support@renewaire.com
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 17
|
|
|
+OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+ACCESSORIES
|
|
|
+
|
|
|
+Controls
|
|
|
+
|
|
|
+Standard controls are intended to turn RenewAire single/multi-family energy recovery ventilation systems on and off at appropriate
|
|
|
+times. Installation and set-up is an easy process. RenewAire single/multi-family units are available standard with interface and
|
|
|
+controls.
|
|
|
+BR Series: Built-in percentage run-time with furnace interlock
|
|
|
+GR Series: 120V line voltage controls
|
|
|
+EV Series: Percentage run timer or percentage run timer with furnace interlock and push button lighted controls
|
|
|
+
|
|
|
+ u Digital time clock, CO2 sensors, IAQ sensors and motion occupancy sensors - Can be applied with external 24V supply
|
|
|
+SL Series: Built-in low voltage transformer for use with percentage run timer or push button lighted controls for on/off, continuous and/or
|
|
|
+
|
|
|
+ boost mode operation
|
|
|
+ u Digital time clock, CO2 sensors, IAQ sensors and motion occupancy sensors - Can be applied with internal low voltage transformer
|
|
|
+
|
|
|
+See individual submittal pages for availability by model.
|
|
|
+
|
|
|
+PERCENTAGE TIMER u Two-wire, low-voltage connection
|
|
|
+
|
|
|
+Primary control for SL70, EV90, EV90P,
|
|
|
+EV130, EV200, EV240 & EV300
|
|
|
+
|
|
|
+u Units can run an adjustable amount of
|
|
|
+ time each hour
|
|
|
+
|
|
|
+PERCENTAGE TIMER WITH FURNACE INTERLOCK PTL Control
|
|
|
+ FM Control
|
|
|
+Alternate primary control for SL70, EV90, PBL Control - requires PTL Control
|
|
|
+EV90P, EV130, EV200, EV240 & EV300
|
|
|
+
|
|
|
+u Low-voltage wire connects to EV unit u Six-wire, low-voltage connection
|
|
|
+ and either thermostat or furnace control
|
|
|
+ to turn on furnace blower
|
|
|
+
|
|
|
+PUSH-BUTTON POINT OF USE TIMER
|
|
|
+
|
|
|
+Secondary control used in combination with
|
|
|
+PTL control for SL70
|
|
|
+
|
|
|
+u Push-button control turns on unit from u Push 2 times for 40 minutes or 3 times
|
|
|
+ bathrooms or other intermittent exhaust for 60 minutes
|
|
|
+ locations
|
|
|
+ u Two-wire, low-voltage connection to PTL
|
|
|
+u One-touch, 20-minute run-time control
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+18 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+ACCESSORIES
|
|
|
+
|
|
|
+See individual submittal pages for availability by model.
|
|
|
+
|
|
|
+DIGITAL TIME CLOCK u Wall mount or outdoor enclosure options
|
|
|
+ u Wall mount fits any 4" x 4" electrical box
|
|
|
+u Up to 8 on/off cycles per day or 56 per
|
|
|
+ week
|
|
|
+
|
|
|
+u 24 VAC power requirement
|
|
|
+u Battery back-up
|
|
|
+
|
|
|
+ TC7D-W
|
|
|
+ Wall Mount
|
|
|
+
|
|
|
+ TC7D-E Control In
|
|
|
+ NEMA 3R Enclosures
|
|
|
+
|
|
|
+CO2 SENSORS u Self calibrates during periods of low
|
|
|
+ occupancy
|
|
|
+u Adjustable control from 400-2000 PPM
|
|
|
+u Digital display u Wall mount or add duct mount accessory
|
|
|
+u 24 VAC power requirement
|
|
|
+u Computer/BAS interface for information and CO2-D
|
|
|
+ Duct Mount
|
|
|
+ control
|
|
|
+
|
|
|
+ CO2-W
|
|
|
+ Wall Mount
|
|
|
+
|
|
|
+IAQ SENSORS u Selectable 0-5 or 0-10V dc signal
|
|
|
+ u 24 VAC power required
|
|
|
+u Measures TVOC u Internal menu for easy set-up
|
|
|
+u Direct correlation to CO2 levels
|
|
|
+u 0-2000 ppm CO2 equivalent output IAQ-D
|
|
|
+ Duct Mount
|
|
|
+ signal
|
|
|
+u Digital display on wall mount
|
|
|
+
|
|
|
+ IAQ-W
|
|
|
+ Wall Mount
|
|
|
+
|
|
|
+MOTION OCCUPANCY SENSORS
|
|
|
+
|
|
|
+u Passive infared sensor u Coverage floor space
|
|
|
+u Adjustable time-off delay to 30 minutes
|
|
|
+u 24 VAC power requirement - Ceiling mount: 1500 sq. ft.
|
|
|
+u Ceiling mount or directable wall mount - Wall mount: 2500 sq. ft.
|
|
|
+
|
|
|
+ u Major motion area MC-C MC-W
|
|
|
+ Ceiling Mount Wall Mount
|
|
|
+ - Ceiling mount: 50 ft. diameter
|
|
|
+ - Wall mount: 68 x 50 ft.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 19
|
|
|
+OPTIONS & ACCESSORIES MERV13 Filter
|
|
|
+ Wall Bracket Kit
|
|
|
+ACCESSORIES Painted Cabinet
|
|
|
+
|
|
|
+See individual submittal pages for availability by model.
|
|
|
+
|
|
|
+Filters
|
|
|
+
|
|
|
+MERV13 FILTERS (SL ONLY)
|
|
|
+u Pleated filter with beverage board fitted
|
|
|
+
|
|
|
+ frame for OA airstream
|
|
|
+
|
|
|
+Mounting
|
|
|
+
|
|
|
+WALL BRACKET KIT (SL ONLY)
|
|
|
+u For vertical installation on stud walls or
|
|
|
+
|
|
|
+ field-supplied support/backing panels
|
|
|
+
|
|
|
+Paint
|
|
|
+
|
|
|
+EXTERIOR PAINT
|
|
|
+u Custom colors available
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+20 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+ACCESSORIES
|
|
|
+
|
|
|
+See individual submittal pages for availability by model.
|
|
|
+
|
|
|
+Hoods and Dampers
|
|
|
+
|
|
|
+VB106 & VW106 u Low pressure drop design
|
|
|
+u 6" vinyl wall caps u Cleanable metal screen
|
|
|
+u Brown (VB) or white (VW)
|
|
|
+
|
|
|
+VT8 u 4 removeable flaps
|
|
|
+u 8" vinyl weatherhood u 1/4" plastic screen
|
|
|
+u Taupe
|
|
|
+u 1-1/2" channel for siding u Hood type wall cap
|
|
|
+ u 1/4" metal screen
|
|
|
+FA8-G
|
|
|
+u 8" wall cap
|
|
|
+u Galvanized finish
|
|
|
+
|
|
|
+FA8-P u Paintable
|
|
|
+u 8" wall cap u 1/4" metal screen
|
|
|
+u Galvanneal finish
|
|
|
+
|
|
|
+VW12X8 u Flush mount
|
|
|
+u 12" x 8" x 8" round louver u 1/2" metal screen
|
|
|
+u Galvanized finish
|
|
|
+
|
|
|
+BD6 & BD8 u Male/female ends
|
|
|
+u 6" & 8" backdraft damper
|
|
|
+u Mechanical “butterfly” design
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 21
|
|
|
+OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+ACCESSORIES
|
|
|
+
|
|
|
+RH Series Electric Duct Heater
|
|
|
+
|
|
|
+AVA I L A B L E O N S I N G L E / M U LT I - FA M I LY A N D L I G H T C O M M E R C I A L U N I T S ( S O M E E X C E P T I O N S A P P LY )
|
|
|
+
|
|
|
+RenewAire offers the highest-efficiency energy recovery ventilators (ERVs) on the market. However, during winter
|
|
|
+conditions, supply air from the ERV may be less than optimal for space conditions. By adding R E N E W A I R E ’ S
|
|
|
+R O U N D E L E C T R I C D U C T H E AT E R as an option to our single/multi-family and light
|
|
|
+commercial ERVs, RenewAire can now heat supply air during cooler months to enhance indoor comfort, all via one
|
|
|
+package for ERVs and heaters from a single source.
|
|
|
+
|
|
|
+ RH SERIES
|
|
|
+ RH-W SHOWN
|
|
|
+
|
|
|
+KEY BENEFITS u Easy installation: A ZERO clearance rating to combustibles
|
|
|
+ allows designers and contractors to apply RenewAire heaters
|
|
|
+u A single source reduces time and costs: A single with less restrictions onsite.
|
|
|
+ information source, a single purchase point and a single
|
|
|
+ approval package for ERVs and heaters reduces design time u Ultimate reliability: RenewAire heaters come with our two-year
|
|
|
+ and costs, and streamlines logistics for design engineers warranty and unmatched reliability. Single-source responsibility
|
|
|
+ and contractors. offers contractors and end users peace of mind and a single call
|
|
|
+ location for technical, start-up and commissioning questions.
|
|
|
+u More flexibility: RenewAire offers design engineers the
|
|
|
+ capacity to specify ERVs with a matching heater to boost u Highly certified: CSA certified and evaluated to the applicable
|
|
|
+ flexibility and provide heated air to a single space or ANSI/UL and CSA Standards, for use in the U.S. and Canada.
|
|
|
+ multiple spaces.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+22 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+RH SERIES Electric Duct Heater (1-11.5 kW)
|
|
|
+ Accessory
|
|
|
+
|
|
|
+ LR 30551
|
|
|
+
|
|
|
+ELECTRIC DUCT HEATER NEW SPECIFICATIONS
|
|
|
+
|
|
|
+ Heater Type: Standard Features:
|
|
|
+ Electric Duct Heater Open-coil element
|
|
|
+ High grade nickel-chrome element wire
|
|
|
+ Typical KW Range: Thermostat - Integral (RH-D),
|
|
|
+ 1–11.5 kW (1, 2, 3, 4, 5, 6, 8, 10, 11.5 kW)
|
|
|
+ Wall mount (RH-W)
|
|
|
+ Voltages & Phase: Modulating heat output (SCR control)
|
|
|
+ Single phase - 120, 208 and 240V Vertical or horizontal operation
|
|
|
+ Automatic limit switch for primary
|
|
|
+ Control Voltage:
|
|
|
+ 24 VAC over-temperature protection
|
|
|
+ Manual reset limit switch for secondary
|
|
|
+RH-D (Integral Thermostat)
|
|
|
+ over-temperature protection
|
|
|
+ Airflow sensor
|
|
|
+ Standard control transformer - 24 VAC
|
|
|
+ Corrosion resistant galvanized steel
|
|
|
+ Round duct collars
|
|
|
+ High voltage terminal block connections
|
|
|
+ Grounding lug
|
|
|
+ Mounting flanges
|
|
|
+
|
|
|
+ Note: Electric duct heater designed for indoor ductwork installation only.
|
|
|
+
|
|
|
+ Duct Collars kW V Size Width (X) Height (Y) Depth (Z)
|
|
|
+ 6" 11 1/2" 8" 11 1/2"
|
|
|
+ 8" 1, 2 120, 208, 240 A 11 1/2" 10" 13 1/2"
|
|
|
+ 8" 11 1/2" 10" 13 1/2"
|
|
|
+ 10" 3, 4, 5 208 B 11 1/2" 10" 13 1/2"
|
|
|
+ 10" 11 1/2" 10" 13 1/2"
|
|
|
+ 10" 3, 4, 5, 6 240 B 15 1/2" 12" 15 1/2"
|
|
|
+ 12" 15 1/2" 12" 15 1/2"
|
|
|
+ 3, 4, 5 208 B
|
|
|
+
|
|
|
+ 3, 4, 5, 6 240 B
|
|
|
+
|
|
|
+ RH-W (Wall Mount Thermostat) 8, 10, 11.5 240 C
|
|
|
+
|
|
|
+Download specification at: 6, 8, 10, 11.5 240 C
|
|
|
+renewaire.com/specifications
|
|
|
+
|
|
|
+ Y Z DIMENSIONS IN INCHES
|
|
|
+ SIZE X Y Z
|
|
|
+ XA B C
|
|
|
+ A 11.5 8.0 11.5
|
|
|
+ B 11.5 10.0 13.5
|
|
|
+ C 15.5 12.0 15.5
|
|
|
+
|
|
|
+ RH SERIES HEATER CAPACITY
|
|
|
+ RH SERIES HEATER CAPACITY
|
|
|
+ 13
|
|
|
+Minimum Airflow Heater Capacity HEATER CAPACITY - kW
|
|
|
+ (CFM) (kW) 12
|
|
|
+
|
|
|
+ 30 1.00 11
|
|
|
+ 60 2.00
|
|
|
+ 90 3.00 10
|
|
|
+ 120 4.00
|
|
|
+ 150 5.00 9
|
|
|
+ 180 6.00
|
|
|
+ 240 8.00 8
|
|
|
+ 300 10.00
|
|
|
+ 345 11.50 7
|
|
|
+
|
|
|
+ 6 SAFE OPERATING
|
|
|
+ 5
|
|
|
+ RANGE
|
|
|
+ 4
|
|
|
+
|
|
|
+ 3
|
|
|
+
|
|
|
+ 2
|
|
|
+
|
|
|
+ 1
|
|
|
+
|
|
|
+ 0
|
|
|
+
|
|
|
+ 30 60 90 120 150 180 210 240 270 300 330 360 500 750 1000
|
|
|
+
|
|
|
+ AIRFLOW - CFM
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 23
|
|
|
+CERTIFICATIONS & PERFORMANCE
|
|
|
+
|
|
|
+HVI TESTED/CERTIFIED
|
|
|
+
|
|
|
+PER CSA C439
|
|
|
+
|
|
|
+ BR130 - Ventilation Performance BR130 - Energy Performance
|
|
|
+
|
|
|
+Ext. Static Pressure Net Supply Airflow Gross Airflow Supply Net Airflow Average Sensible Recovery Adjusted Sensible Net Moisture
|
|
|
+ Temperature L/S CFM Power Watts Efficiency % Recovery Transfer %
|
|
|
+ Supply Exhaust C° F°
|
|
|
+ 58 124 Efficiency %
|
|
|
+Pa in. wg L/S CFM L/S CFM L/S CFM Heating
|
|
|
+ 59 126
|
|
|
+25 0.1 70 148 71 151 75 159 0° 32°
|
|
|
+
|
|
|
+50 0.2 66 141 67 143 69 147 Cooling
|
|
|
+
|
|
|
+75 0.3 62 132 63 134 64 135 35° 95° 121 72 78 55
|
|
|
+
|
|
|
+100 0.4 53 113 54 115 56 119 Total Adjusted Total
|
|
|
+
|
|
|
+125 0.5 44 94 45 96 47 99 Recovery Efficiency % Recovery Efficiency %
|
|
|
+
|
|
|
+150 0.6 32 69 33 70 29 62 121 46 48
|
|
|
+
|
|
|
+175 0.7 24 52 25 53 21 45
|
|
|
+
|
|
|
+ EV90/GR90 - Ventilation Performance EV90/GR90 - Energy Performance
|
|
|
+
|
|
|
+Ext. Static Pressure Net Supply Airflow Gross Airflow Supply Net Airflow Average Sensible Recovery Adjusted Sensible Net Moisture
|
|
|
+ Temperature L/S CFM Power Watts Efficiency % Recovery Transfer %
|
|
|
+ Supply Exhaust C° F°
|
|
|
+ 42 90 Efficiency %
|
|
|
+Pa in. wg L/S CFM L/S CFM L/S CFM Heating
|
|
|
+ 42 90
|
|
|
+25 0.1 53 113 54 115 52 109 0° 32°
|
|
|
+
|
|
|
+50 0.2 46 98 47 100 46 97 Cooling
|
|
|
+
|
|
|
+75 0.3 40 85 41 87 40 85 35° 95° 46 72 77 37
|
|
|
+
|
|
|
+100 0.4 34 73 35 74 34 72 Total Adjusted Total
|
|
|
+
|
|
|
+125 0.5 27 58 28 59 28 60 Recovery Efficiency % Recovery Efficiency %
|
|
|
+
|
|
|
+150 0.6 19 40 19 41 22 47 44 46 48
|
|
|
+
|
|
|
+ EV90P - Ventilation Performance EV90P - Energy Performance
|
|
|
+
|
|
|
+Ext. Static Pressure Net Supply Airflow Gross Airflow Supply Net Airflow Average Power Sensible Recovery Adjusted Sensible Net Moisture
|
|
|
+ Temperature L/S CFM Watts Efficiency % Recovery Transfer %
|
|
|
+ Supply Exhaust C° F°
|
|
|
+ 42 90 Efficiency %
|
|
|
+Pa in. wg L/S CFM L/S CFM L/S CFM Heating
|
|
|
+ 42 90
|
|
|
+25 0.1 51 108 52 110 52 110 0° 32°
|
|
|
+
|
|
|
+50 0.2 47 99 48 101 47 100 Cooling
|
|
|
+
|
|
|
+75 0.3 41 87 42 89 42 89 35° 95° 44 80 83 64
|
|
|
+
|
|
|
+100 0.4 35 73 36 75 36 76 Total Adjusted Total
|
|
|
+
|
|
|
+125 0.5 26 56 27 57 27 58 Recovery Efficiency % Recovery Efficiency %
|
|
|
+
|
|
|
+150 0.6 20 42 20 42 21 44 44 63 71
|
|
|
+
|
|
|
+ EV130 - Ventilation Performance EV130 - Energy Performance
|
|
|
+
|
|
|
+Ext. Static Pressure Net Supply Airflow Gross Airflow Supply Net Airflow Average Power Sensible Recovery Adjusted Sensible Net Moisture
|
|
|
+ Temperature L/S CFM Watts Efficiency % Recovery Transfer %
|
|
|
+ Supply Exhaust C° F°
|
|
|
+ 61 130 Efficiency %
|
|
|
+Pa in. wg L/S CFM L/S CFM L/S CFM Heating
|
|
|
+ 61 130
|
|
|
+25 0.1 77 165 79 168 79 168 0° 32°
|
|
|
+
|
|
|
+50 0.2 72 153 73 156 73 156 Cooling
|
|
|
+
|
|
|
+75 0.3 64 137 66 140 66 140 35° 95° 102 71 75 53
|
|
|
+
|
|
|
+100 0.4 59 126 61 129 61 129 Total Adjusted Total
|
|
|
+
|
|
|
+125 0.5 49 104 50 106 50 106 Recovery Efficiency % Recovery Efficiency %
|
|
|
+
|
|
|
+150 0.6 37 79 38 81 38 81 102 48 51
|
|
|
+
|
|
|
+ EV200 - Ventilation Performance EV200 - Energy Performance
|
|
|
+
|
|
|
+Ext. Static Pressure Net Supply Airflow Gross Airflow Supply Net Airflow Average Power Sensible Recovery Adjusted Sensible Net Moisture
|
|
|
+ Temperature L/S CFM Watts Efficiency % Recovery Transfer %
|
|
|
+ Supply Exhaust C° F°
|
|
|
+ 85 181 Efficiency %
|
|
|
+Pa in. wg L/S CFM L/S CFM L/S CFM Heating
|
|
|
+ 85 180
|
|
|
+25 0.1 97 207 100 213 109 232 0° 32°
|
|
|
+
|
|
|
+50 0.2 90 192 93 199 104 221 Cooling
|
|
|
+
|
|
|
+75 0.3 88 186 90 192 101 216 35° 95° 157 78 84 62
|
|
|
+
|
|
|
+100 0.4 83 176 85 181 96 204 Total Adjusted Total
|
|
|
+
|
|
|
+125 0.5 79 168 81 173 88 187 Recovery Efficiency % Recovery Efficiency %
|
|
|
+
|
|
|
+150 0.6 70 149 72 154 76 162 155 52 54
|
|
|
+
|
|
|
+175 0.7 57 122 59 126 68 145
|
|
|
+
|
|
|
+ EV240 - Ventilation Performance EV240 - Energy Performance
|
|
|
+
|
|
|
+Ext. Static Pressure Net Supply Airflow Gross Airflow Supply Net Airflow Average Power Sensible Recovery Adjusted Sensible Net Moisture
|
|
|
+ Temperature L/S CFM Watts Efficiency % Recovery Transfer %
|
|
|
+ Supply Exhaust C° F°
|
|
|
+ 111 236 Efficiency %
|
|
|
+Pa in. wg L/S CFM L/S CFM L/S CFM Heating
|
|
|
+ 108 229
|
|
|
+25 0.1 125 265 129 273 132 280 0° 32°
|
|
|
+
|
|
|
+50 0.2 121 256 124 263 126 267 Cooling
|
|
|
+
|
|
|
+75 0.3 118 250 120 254 121 256 35° 95° 216 75 80 57
|
|
|
+
|
|
|
+100 0.4 114 242 116 246 117 248 Total Adjusted Total
|
|
|
+
|
|
|
+125 0.5 108 229 111 235 110 233 Recovery Efficiency % Recovery Efficiency %
|
|
|
+
|
|
|
+150 0.6 101 214 103 218 102 216 213 53 56
|
|
|
+
|
|
|
+175 0.7 92 195 94 199 93 197
|
|
|
+
|
|
|
+200 0.8 80 170 82 174 79 167
|
|
|
+
|
|
|
+ EV300 - Ventilation Performance EV300 - Energy Performance
|
|
|
+
|
|
|
+Ext. Static Pressure Net Supply Airflow Gross Airflow Supply Net Airflow Average Power Sensible Recovery Adjusted Sensible Net Moisture
|
|
|
+ Temperature L/S CFM Watts Efficiency % Recovery Transfer %
|
|
|
+ Supply Exhaust C° F°
|
|
|
+ 139 297 Efficiency %
|
|
|
+Pa in. wg L/S CFM L/S CFM L/S CFM Heating
|
|
|
+ 138 294
|
|
|
+100 0.4 147 311 150 317 143 303 0° 32°
|
|
|
+
|
|
|
+125 0.5 139 295 142 301 133 283 Cooling
|
|
|
+
|
|
|
+150 0.6 131 277 133 282 125 265 35° 95° 315 67 73 54
|
|
|
+
|
|
|
+175 0.7 121 256 123 261 108 230 Total Adjusted Total
|
|
|
+
|
|
|
+200 0.8 101 215 103 219 94 198 Recovery Efficiency % Recovery Efficiency %
|
|
|
+
|
|
|
+225 0.9 90 191 92 195 74 156 313 46 49
|
|
|
+
|
|
|
+250 1.0 80 170 82 174 47 99
|
|
|
+
|
|
|
+ SL70L/SL70H - Ventilation Performance SL70L/SL70H - Energy Performance
|
|
|
+
|
|
|
+Ext. Static Pressure Net Supply Airflow Gross Airflow Supply Net Airflow Average Power Sensible Recovery Adjusted Sensible Net Moisture
|
|
|
+ Temperature L/S CFM Watts Efficiency % Recovery Transfer %
|
|
|
+ Supply Exhaust C° F°
|
|
|
+ 25 53 Efficiency %
|
|
|
+Pa in. wg L/S CFM L/S CFM L/S CFM Heating
|
|
|
+ 25 53
|
|
|
+25 0.1 51 108 53 112 55 117 0° 32°
|
|
|
+
|
|
|
+50 0.2 48 102 50 106 53 112 Cooling
|
|
|
+
|
|
|
+75 0.3 45 95 48 102 51 108 35° 95° 29 75 79 57
|
|
|
+
|
|
|
+100 0.4 43 91 46 97 49 104 Total Adjusted Total
|
|
|
+
|
|
|
+125 0.5 42 89 44 93 47 100 Recovery Efficiency % Recovery Efficiency %
|
|
|
+
|
|
|
+150 0.6 40 85 42 89 44 93 31 62 64
|
|
|
+
|
|
|
+175 0.7 38 81 40 85 42 89
|
|
|
+
|
|
|
+200 0.8 36 76 38 81 39 83
|
|
|
+
|
|
|
+225 0.9 33 70 35 74 35 74
|
|
|
+
|
|
|
+250 1.0 29 61 31 66 31 66
|
|
|
+
|
|
|
+24 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ CERTIFICATIONS & PERFORMANCE
|
|
|
+
|
|
|
+INDEPENDENTLY TESTED
|
|
|
+
|
|
|
+PER CSA C439
|
|
|
+
|
|
|
+ BR70 - Ventilation Performance BR70 - Energy Performance
|
|
|
+
|
|
|
+Ext. Static Pressure Net Supply Airflow Gross Airflow Supply Net Airflow Average Power Sensible Recovery Adjusted Sensible Net Moisture
|
|
|
+ Temperature L/S CFM Watts Efficiency % Recovery Transfer %
|
|
|
+ Supply Exhaust C° F°
|
|
|
+ 32 69 Efficiency %
|
|
|
+Pa in. wg L/S CFM L/S CFM L/S CFM Heating
|
|
|
+ 30 64
|
|
|
+25 0.1 41 86 42 89 46 97 0° 32°
|
|
|
+
|
|
|
+50 0.2 34 73 35 75 39 84 Cooling
|
|
|
+
|
|
|
+75 0.3 28 59 29 61 32 69 35° 95° 94 66 75 53
|
|
|
+
|
|
|
+100 0.4 21 46 22 47 25 53 Total Adjusted Total
|
|
|
+
|
|
|
+Electrical Requirements Volts 120 Amps 1.0 Recovery Efficiency % Recovery Efficiency %
|
|
|
+
|
|
|
+ 94 42 47
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 25
|
|
|
+ RENEWAIRE ERVs
|
|
|
+
|
|
|
+ VENTILATION SOLUTIONS FOR EVERY APPLICATION
|
|
|
+
|
|
|
+ SL SERIES
|
|
|
+
|
|
|
+ u Residential ERVs—four-duct design
|
|
|
+ u Indoor
|
|
|
+ u 51-76 CFM continuous mode
|
|
|
+ u 76-94 CFM boost mode
|
|
|
+
|
|
|
+ BR SERIES
|
|
|
+
|
|
|
+ u Residential ERVs—two-duct design
|
|
|
+ u Indoor
|
|
|
+ u 40-140 CFM
|
|
|
+
|
|
|
+ EV SERIES
|
|
|
+
|
|
|
+ u Residential and light commercial
|
|
|
+ ERVs—four-duct design
|
|
|
+
|
|
|
+ u Indoor/outdoor (varies by model)
|
|
|
+ u 40-540 CFM
|
|
|
+
|
|
|
+ HE SERIES
|
|
|
+
|
|
|
+ u Commercial ERVs—packaged
|
|
|
+ solutions
|
|
|
+
|
|
|
+ u Indoor/outdoor
|
|
|
+ u 250-7,950 CFM
|
|
|
+
|
|
|
+ LE SERIES
|
|
|
+
|
|
|
+ u Commercial ERVs—large capacity
|
|
|
+ u Indoor/outdoor
|
|
|
+ u 1,500-11,000 CFM
|
|
|
+
|
|
|
+ FOR CERTIFICATION DETAILS SEE UNIT SUBMITTALS ON RENEWAIRE.COM
|
|
|
+
|
|
|
+26 RENEWAIRE.COM 1.800.627.4499
|
|
|
+RENEWAIRE ERVs
|
|
|
+
|
|
|
+ VENTILATION SOLUTIONS FOR EVERY APPLICATION
|
|
|
+
|
|
|
+ CA SERIES
|
|
|
+
|
|
|
+ u Applied ERVs—modular cabinets
|
|
|
+ u Indoor/outdoor
|
|
|
+ u 500-4,400 CFM
|
|
|
+ u Stackable to 20,000 CFM
|
|
|
+
|
|
|
+ PA SERIES
|
|
|
+
|
|
|
+ u Applied ERVs—modular panels
|
|
|
+ u Indoor
|
|
|
+ u 1500-unlimited CFM
|
|
|
+
|
|
|
+ RD SERIES
|
|
|
+
|
|
|
+ u Commercial—Dedicated Outdoor
|
|
|
+ Air System (DOAS)
|
|
|
+
|
|
|
+ u Indoor/outdoor
|
|
|
+ u 500-4,250 CFM
|
|
|
+
|
|
|
+ DN SERIES
|
|
|
+
|
|
|
+ u Commercial—Dedicated Outdoor
|
|
|
+ Air System (DOAS)
|
|
|
+
|
|
|
+ u Indoor/outdoor
|
|
|
+ u 375-4,950 CFM
|
|
|
+
|
|
|
+OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+u ECM motors u Bypass economizers
|
|
|
+
|
|
|
+u Variable frequency drives u Electric duct heaters
|
|
|
+
|
|
|
+u Motorized isolation dampers u Filter alarms
|
|
|
+
|
|
|
+u Combo curbs
|
|
|
+
|
|
|
+FOR CERTIFICATION DETAILS SEE UNIT SUBMITTALS ON RENEWAIRE.COM
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 27
|
|
|
+ORDERING & SUPPORT
|
|
|
+
|
|
|
+ INDOOR AIR QUALITY MATTERS
|
|
|
+
|
|
|
+ u Deficient IAQ is an EPA top-five health risk
|
|
|
+
|
|
|
+ u People spend 90% of their time indoors
|
|
|
+
|
|
|
+ u Indoor air can be 2-5 times and up to 100 times
|
|
|
+ more polluted than outdoor air
|
|
|
+
|
|
|
+BENEFITS OF INCREASED VENTILATION
|
|
|
+
|
|
|
+ BETTER IMPROVED INCREASED
|
|
|
+ HEALTH COGNITIVE PRODUCTIVITY
|
|
|
+ FUNCTION
|
|
|
+
|
|
|
+TECHNICAL/APPLICATIONS SUPPORT
|
|
|
+The goal of our technical-support team is to provide the BEST CUSTOMER SERVICE
|
|
|
+in the HVAC industry. You can count on our knowledgeable and seasoned staff for all your technical,
|
|
|
+application and service needs, and we’ll respond quickly and effectively to answer any of your questions.
|
|
|
+
|
|
|
+ CONTACT RENEWAIRE
|
|
|
+
|
|
|
+ PHONE: FOR TECHNICAL SUPPORT:
|
|
|
+ 1.800.627.4499 RenewaireSupport@renewaire.com
|
|
|
+
|
|
|
+ FAX: TO PLACE AN ORDER:
|
|
|
+ 608.221.2824 RenewaireOrders@renewaire.com
|
|
|
+
|
|
|
+28 RENEWAIRE.COM 1.800.627.4499
|
|
|
+RELEVANT RENEWAIRE
|
|
|
+
|
|
|
+EVERYWHERE TEMPERS THE AIR
|
|
|
+
|
|
|
+EVERY GEOGRAPHIC REGION Our ERVs moderate the extremes
|
|
|
+Our ERVs function perfectly across the world in every of outdoor supply-air temperature
|
|
|
+geographic region. and humidity year-round, providing
|
|
|
+ a sustainable solution for fresh air
|
|
|
+EVERY CLIMATE that feels like a perfect spring day.
|
|
|
+Our ERVs operate in every climate—from Alaska to
|
|
|
+Florida, and everywhere in between.
|
|
|
+
|
|
|
+EVERY PROJECT
|
|
|
+From massive skyscrapers to cozy residential homes,
|
|
|
+our ERVs can be used in every size project and in every
|
|
|
+code jurisdiction.
|
|
|
+
|
|
|
+APPLIED EVERYWHERE
|
|
|
+
|
|
|
+When indoor occupants breathe in unclean air, this harms their health and causes cognitive impairment. Our ERVs can
|
|
|
+provide cleaner and healthier indoor air for every type of building in the world, thus improving occupants’ wellbeing,
|
|
|
+while also reducing energy costs.
|
|
|
+
|
|
|
+RESIDENTIAL DAYCARE
|
|
|
+The increased airtightness of newer and remodeled Crowded daycare facilities breed deficient IAQ, thus
|
|
|
+homes is causing deficient IAQ, resulting in more health causing health problems for everyone—especially
|
|
|
+problems for indoor occupants. children who are more vulnerable.
|
|
|
+
|
|
|
+COMMERCIAL EDUCATION (LOWER AND HIGHER)
|
|
|
+As commercial buildings become more airtight, With students and teachers packed into tight classrooms,
|
|
|
+deficient IAQ is increasing and causing sickness, instances of deficient IAQ go up, resulting in academic
|
|
|
+absenteeism and decreased productivity. performance and test scores going down.
|
|
|
+
|
|
|
+H E A LT H C A R E GOVERNMENT
|
|
|
+The high occupant density of hospitals, nursing homes Aging and crowded government buildings result in
|
|
|
+and other healthcare facilities results in deficient IAQ deficient IAQ, which can impair worker performance
|
|
|
+and ensuing health problems for patients and staff alike. and productivity.
|
|
|
+
|
|
|
+RESTAURANTS/COFFEE SHOPS EVERY TYPE OF BUILDING
|
|
|
+The large volume of indoor occupants in restaurants Every type of building can benefit from the enhanced
|
|
|
+and coffee shops causes deficient IAQ and subsequent IAQ generated by RenewAire ERVs, including
|
|
|
+health problems. veterinary clinics, nail salons and manufacturing
|
|
|
+ facilities, among others.
|
|
|
+RETAIL
|
|
|
+The high level of foot traffic in retail stores leads
|
|
|
+to deficient IAQ and the potential sickness of shoppers,
|
|
|
+which can negatively impact sales.
|
|
|
+ RENEWAIRE EVERYWHERE LIT112_00 (01/19)
|
|
|
+
|
|
|
+ RenewAire ERVs can be applied everywhere across all
|
|
|
+ commercial, educational, institutional, light industrial
|
|
|
+
|
|
|
+ and residential buildings. Our technology excels in every
|
|
|
+ geographic region, every climate, and every size project.
|
|
|
+
|
|
|
+Member of the S&P Group
|
|
|
+Family of Brands
|
|
|
+ERV
|
|
|
+ CA & PA SERIES
|
|
|
+
|
|
|
+ APPLIED CATALOG
|
|
|
+
|
|
|
+JANUARY 2019
|
|
|
+
|
|
|
+RENEWAIRE.COM | 800.627.4499
|
|
|
+BECAUSE INDOOR
|
|
|
+
|
|
|
+AIR QUALITY MATTERS
|
|
|
+
|
|
|
+As buildings become more airtight due to better application of ERV technologies. Deficient IAQ is a
|
|
|
+construction methodologies, the need for increased serious problem, especially considering:
|
|
|
+and balanced ventilation is critical. Without it, internally u On average, Americans spend 90% of their time indoors
|
|
|
+generated contaminants accumulate and cause deficient u The EPA found that indoor air may be 2-5 times—and
|
|
|
+indoor air quality (IAQ), which leads to significant
|
|
|
+health and cognitive problems for occupants. Industry occasionally greater than 100 times—more polluted
|
|
|
+standards are changing to combat deficient IAQ, and than outdoor air
|
|
|
+codes that adopt these new standards are driving the u The EPA ranks indoor air pollutants as a top-five
|
|
|
+ environmental health risk to occupants
|
|
|
+
|
|
|
+HEALTH PRODUCTIVITY LEARNING
|
|
|
+MAT TERS MAT TERS MAT TERS
|
|
|
+
|
|
|
+ADVERSE EFFECTS ABOUT RENEWAIRE
|
|
|
+
|
|
|
+O F DEFICIENT IAQ For over 30 years, RenewAire has been
|
|
|
+ a pioneer in enhancing IAQ in commercial and
|
|
|
+Deficient IAQ has numerous adverse effects on the residential buildings of every size. This is achieved
|
|
|
+health and cognitive function of building occupants. while maximizing sustainability through our fifth-
|
|
|
+ generation, enthalpic-core, static-plate Energy
|
|
|
+ Health problems: Acute allergies, Recovery Ventilators (ERVs) that optimize energy
|
|
|
+ headaches, coughs, asthma, skin efficiency, lower capital costs via HVAC load
|
|
|
+ irritations and breathing difficulties, reduction and decrease operational expenses
|
|
|
+ as well as chronic illnesses such as by minimizing equipment needs, resulting
|
|
|
+ cancer, liver disease, kidney damage in significant energy savings. Our ERVs are
|
|
|
+ and nervous-system failure. competitively priced, simple to install, easy to use
|
|
|
+ and maintain, have a quick payback and enjoy the
|
|
|
+ Cognitive impairment: Studies by the industry’s best warranty with the lowest claims
|
|
|
+ Harvard School of Public Health and the due to long-term reliability. In 2010, RenewAire
|
|
|
+ Lawrence Berkeley National Laboratory joined the Soler & Palau (S&P) Ventilation Group,
|
|
|
+ found that carbon dioxide (CO )—an providing direct access to the latest in energy-
|
|
|
+ efficient air-moving technologies. For more
|
|
|
+ 2 information, visit: renewaire.com.
|
|
|
+
|
|
|
+ indoor air contaminant—negatively impacted
|
|
|
+ thinking and decision-making at levels
|
|
|
+ commonly found inside homes and buildings.
|
|
|
+ TABLE OF CONTENTS
|
|
|
+
|
|
|
+ TABLE OF
|
|
|
+
|
|
|
+CONTENTS
|
|
|
+
|
|
|
+CA SERIES - Applied TYPE CFM RANGE PAGE
|
|
|
+ Indoor 500-2,200 CFM 4-5
|
|
|
+MODEL Indoor 750-3,300 CFM 4, 6
|
|
|
+CA2XIN Indoor 1,000-4,400 CFM 4, 7
|
|
|
+CA3XIN Rooftop 500-2,200 CFM 8-9
|
|
|
+CA4XIN Rooftop 750-3,300 CFM
|
|
|
+CA2XRT Rooftop 1,000-4,400 CFM 8, 10
|
|
|
+CA3XRT 8, 11
|
|
|
+CA4XRT
|
|
|
+
|
|
|
+PA SERIES - Applied TYPE CFM RANGE PAGE
|
|
|
+ Indoor 1,500-6,600 CFM 12-13
|
|
|
+MODEL Indoor 2,000-8,800 CFM 12, 14
|
|
|
+PA6X Indoor 2,250-9,900 CFM 12, 15
|
|
|
+PA8X Indoor 3,000-13,200 CFM 12, 16
|
|
|
+PA9X
|
|
|
+PA12X
|
|
|
+
|
|
|
+ABOUT RENEWAIRE 2-3
|
|
|
+SPECIFICATIONS & DIMENSIONS 4-16
|
|
|
+CERTIFICATIONS & PERFORMANCE
|
|
|
+ORDERING & SUPPORT 18
|
|
|
+ 19-20
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 1
|
|
|
+ ABOUT RENEWAIRE
|
|
|
+
|
|
|
+ R E N E WA I R E E R Vs
|
|
|
+
|
|
|
+ ACHIEVE SUSTAINABLE IAQ
|
|
|
+
|
|
|
+ RenewAire is a pioneer in enhancing IAQ while maximizing sustainability through enthalpic-core, static-plate Energy
|
|
|
+ Recovery Ventilators (ERVs) that optimize energy efficiency, lower costs by reducing HVAC loads and therefore
|
|
|
+ reduce environmental footprints. Our ERV technology preconditions incoming air with the otherwise-wasted energy
|
|
|
+ (heat and humidity) of the exhaust air going out—all while the airstreams are kept physically separate as certified by
|
|
|
+ the Air Conditioning, Heating and Refrigeration Institute (AHRI) for zero exhaust air transfer at normal balanced operating
|
|
|
+ conditions. As the pioneer of static-plate core technology in North America, RenewAire is the largest ERV producer in the USA.
|
|
|
+
|
|
|
+ OPTIMIZING OA COOLING SEASON RA OA HEATING SEASON RA
|
|
|
+ ENERGY EFFICIENCY
|
|
|
+ EFFICIENT EFFICIENT
|
|
|
+ Energy efficiency is optimized by preconditioning HEAT & HUMIDITY HEAT & HUMIDITY
|
|
|
+ the outside air coming in with the otherwise-wasted
|
|
|
+ heat and humidity of the exhaust air going out. This TRANSFER TRANSFER
|
|
|
+ exchange of energy moderates temperatures and moisture,
|
|
|
+ decreases HVAC equipment needs, drives operational EA FA EA FA
|
|
|
+ efficiencies and conserves energy.
|
|
|
+
|
|
|
+ REDUCING HVAC LOADS INSIDE OUTSIDE
|
|
|
+ Fresh Air Enters Stale Room Air Exits
|
|
|
+ RenewAire technology reduces HVAC loads during both winter and summer. In turn,
|
|
|
+ HVAC equipment size and needs can be decreased and furnaces and air conditioners Fixed Partition
|
|
|
+ can be smaller. This process ensures efficient operations and keeps both energy use and and Spacer Plates
|
|
|
+ costs low, while at the same time maintaining high-level IAQ.
|
|
|
+ (proprietary resin
|
|
|
+ and composite media) Outside Air
|
|
|
+
|
|
|
+ Stale Room Air
|
|
|
+
|
|
|
+ MINIMIZING ENVIRONMENTAL IMPACT
|
|
|
+
|
|
|
+ The combination of less energy used and HVAC loads being reduced conserves resources. Further, our Madison, WI plant
|
|
|
+ is 100% powered by renewable wind energy, and is one of the few buildings worldwide to be LEED and Green Globes
|
|
|
+ certified, as well as having achieved ENERGY STAR Building status. This commitment to sustainable manufacturing
|
|
|
+ minimizes our overall production and distribution environmental footprint.
|
|
|
+
|
|
|
+2
|
|
|
+ ABOUT RENEWAIRE
|
|
|
+
|
|
|
+WHY RENEWAIRE
|
|
|
+
|
|
|
+IS PREFERRED
|
|
|
+
|
|
|
+ BEST VALUE
|
|
|
+
|
|
|
+ u Priced competitively against other ERV models
|
|
|
+ u Due to competitive pricing and decreased costs, payback is short and ROI is maximized
|
|
|
+ u Contractors can pass these significant savings along to their customers
|
|
|
+
|
|
|
+ RELIABLE OPERATION
|
|
|
+
|
|
|
+ u Built-to-last ERVs have lifespans of 25+ years and operate consistently year-round in every extreme,
|
|
|
+ including frost-free performance in all but the most severe winter climates
|
|
|
+
|
|
|
+ u High-efficiency core operates dry in all conditions, meaning no condensate pans
|
|
|
+ u An industry-leading ten-year warranty for the static-plate core, two-year warranty for commercial
|
|
|
+
|
|
|
+ products and a five-year warranty for residential products
|
|
|
+ u Superior product quality results in paramount reliability and longevity
|
|
|
+
|
|
|
+ HIGHEST-QUALITY INDOOR AIR
|
|
|
+
|
|
|
+ u Stale indoor air is replaced with fresh, conditioned and filtered air from
|
|
|
+ the outside, resulting in Enhanced IAQ by removing harmful contaminants
|
|
|
+
|
|
|
+ u Airstreams do not mix and pollutants are not transferred across partition plates
|
|
|
+ u No biocide used; material does not promote biological growth
|
|
|
+ u Moderated temperatures and humidity maintain a comfortable indoor environment
|
|
|
+
|
|
|
+ OPTIMIZED ENERGY EFFICIENCY
|
|
|
+
|
|
|
+ u Efficient heat and humidity transfer recaptures up to 70-80% of the energy exhausted in the airstream
|
|
|
+ u Energy that’s otherwise wasted by conventional ventilation systems (such as bath fans) is reused,
|
|
|
+
|
|
|
+ thus dramatically reducing monthly operation costs
|
|
|
+ u Energy-efficient operation decreases HVAC loads, which cuts down on energy use and costs
|
|
|
+ u The hotter or colder the climate, the more energy is recovered
|
|
|
+
|
|
|
+ HIGHLY CERTIFIED
|
|
|
+
|
|
|
+ u See individual catalog submittal for certification details:
|
|
|
+ u UL u cUL u ETL u HVI u AHRI
|
|
|
+
|
|
|
+ 3
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+ CA INDOOR Energy Recovery Module
|
|
|
+
|
|
|
+ INDOOR UNIT SPECIFICATIONS
|
|
|
+ Modular Cabinets
|
|
|
+
|
|
|
+ Ventilation Type: Insulation:
|
|
|
+ Static plate, heat and humidity transfer One inch, high density, FSK faced, fiberglass
|
|
|
+
|
|
|
+ Standard Features: Options:
|
|
|
+ Insulated sheet metal cabinets with energy Double wall construction
|
|
|
+ Exterior paint - white, custom colors
|
|
|
+ exchange cores and filters.
|
|
|
+ Individual CA-Series units or stacks of units can be Accessories:
|
|
|
+ Filters - MERV 13, 2" (shipped loose)
|
|
|
+ built into larger air handling systems.
|
|
|
+ Blower not included and must be specified to meet
|
|
|
+
|
|
|
+ job requirements.
|
|
|
+
|
|
|
+n5a.xlylssxis.xlsx dP CCAh2aXrt‐4XITNhermal Performance Ratings G5 2015.2.xlsx 2 Cores (IOM)
|
|
|
+ CA3XIN
|
|
|
+ Description CA2XIN CA4XIN
|
|
|
+
|
|
|
+ Download specification at: Typical Airflow 500-2,200 750-3,300 1,000-4,400
|
|
|
+ renewaire.com/specifications Range CFM Two L125-G5 Three L125-G5 Four L125-G5
|
|
|
+
|
|
|
+ AHRI 1060 Certified Core
|
|
|
+
|
|
|
+ Unit Dimensions 36" L x 42 1/2" W x 35" H 36" L x 62 1/4" W x 35" H 36" L x 81 3/4" W x 35" H
|
|
|
+ & Weight
|
|
|
+ 225-304 lbs. 325-430 lbs. 400-531 lbs.
|
|
|
+
|
|
|
+Applied Products Max. Shipping Dimensions 62" L x 42" W x 40" H 70" L x 47" W x 40" H 96" L x 47" W x 40" H
|
|
|
+ 500 lbs. 620 lbs.
|
|
|
+ & Weight (on pallet) 350 lbs.
|
|
|
+
|
|
|
+Some ventilation projects require more flexibility than sphaecektamgeedtaTlEhcRaeVbrsimnaelatlsolwwP.ietRhrefMF2oni0Eelrt"wRmexVArasi2r8:ne0Moc"oreEfxMfReR2VErsa"R8tbV:ino1tgh3s G5 2015.2.xlsxTotal qty. 4 To3taCl qotry.e6s (IOM) Total qty. 8
|
|
|
+indoor and outdoor cabinets of ERV cores in insulated
|
|
|
+
|
|
|
+filters. Realize your energy-efficiency goals with RenewAire’s Applied Products family of ERVs.
|
|
|
+
|
|
|
+• Cost effective energy recovery for virtually any air handling system
|
|
|
+
|
|
|
+• Complete flexibility in locating field supplied blowers CORE PERFORMANCE
|
|
|
+
|
|
|
+ A–IgRreFatLfoOr aWcousPticEaRllyFseOnsRitivMe aAppNlicCatiEons
|
|
|
+
|
|
|
+• AHRI certified performance data for efficiency and cross leakage
|
|
|
+
|
|
|
+• UL tested flammability and smoke gfoeAArncieirorrfamfltloiomownwertch(i(aaCCtl amFFpeMpMelitc)s)ations
|
|
|
+ NFPA 90A and 90B test standards
|
|
|
+ Airflow (CFM)
|
|
|
+
|
|
|
+• Ten year core performance warranty 500 1000 1500 2000
|
|
|
+ 90% 3000 3500
|
|
|
+CA-Series StSattiatcicPrPerseusruere 21..05 Effectiveness (%)
|
|
|
+ DrDorpop(i(ni.n.w.wg.)g) 4000
|
|
|
+• Cores stacked side-by-1s.i5de horizontally Thermal Performance Ratings G5 2015.2.xlsx 4 Cores (IOM)
|
|
|
+• Each cabinet contains 21, .30, or 4 energy exchange cores
|
|
|
+ 70%
|
|
|
+• Indoor (IN) and outdoor1(.R0T) models available
|
|
|
+ 0.5
|
|
|
+• Indoor cabinets can be0s.t5acked up to five high (with support structure)
|
|
|
+ accommodating up to 20,000 CFM (NOTE: outdoor cabinets cannot be stacked) 50%
|
|
|
+
|
|
|
+• DSioduebaleccweaslsl csoenrvsitcruecdtiooo0n0r..0(o0sp) t00ional 1000 2000 3000 4000 CA2XIN
|
|
|
+• 1000 2000 3000 4000
|
|
|
+ 30%
|
|
|
+
|
|
|
+PA-Series Note: Airflow performance includes effect of clean, Airflow (CFM)
|
|
|
+ standard filter supplied with unit.
|
|
|
+
|
|
|
+• Cores stacked vertically 3 or 4 cores high 500 1000 1500 2000 2500
|
|
|
+
|
|
|
+• Each cabinet contains 6, 8, 9, or 12 energy exchange cores Effectiveness (%) 90%
|
|
|
+
|
|
|
+• Indoor (IN) models only
|
|
|
+
|
|
|
+• Indoor cabinets can be joined together lengthwise to accommodate unlimited airflows 70%
|
|
|
+
|
|
|
+• Top access service panels
|
|
|
+
|
|
|
+• Shipped knock down (K) or factory assembled (A) 50%
|
|
|
+
|
|
|
+ - Each component fits through 3 foot swing door. Ideal for tight applications.
|
|
|
+
|
|
|
+ APPLICATION Installation Example CA3XIN
|
|
|
+
|
|
|
+ Central Air Handler using CA4X and exhaust and make-up air blowers. 30%
|
|
|
+ (CA-Series provide side service access and a “side-by-side” airflow arrangement.)
|
|
|
+ Airflow (CFM)
|
|
|
+
|
|
|
+ CA4X 1000 2000 3000
|
|
|
+ 90%
|
|
|
+ Effectiveness (%)
|
|
|
+ 70%
|
|
|
+
|
|
|
+ Similar designs can use PA-Series arrays. 50%
|
|
|
+ (PA-Series provide top service access and an “over-under” airflow arrangement.)
|
|
|
+ CA4XIN
|
|
|
+66
|
|
|
+ (800) 627-4499 • Fax: (608) 221-2824 30%
|
|
|
+ At AHRI 1060 standard conditions.
|
|
|
+ See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+4 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ CA2XIN Energy Recovery Module
|
|
|
+
|
|
|
+ Door 33 7/8" Minimum 35" Minimum ABBREVIATION
|
|
|
+ Swing Service Area Typ. Service Area Typ. EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ Door RA: Room Air to be exhausted
|
|
|
+ Swing FA: Fresh Air to inside
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ TOP VIEW 36" Overall Unit may be installed in any
|
|
|
+ 34 7/8" Case orientation.
|
|
|
+ 42 3/8" Overall NOTE:
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 42 3/8" Case
|
|
|
+ 5 3/4"
|
|
|
+ Typ.
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 5 34 7/8" Overall 1 1/8"
|
|
|
+ Typ.
|
|
|
+ Note: Pleated, disposable 1 1/8"
|
|
|
+ 20" X 20" X 2" filters are Typ.
|
|
|
+ provided for installation 34 7/8" Case
|
|
|
+ and are interchangeable 14 1/8" X 14 1/8"
|
|
|
+ based on your airflow Typ.
|
|
|
+ path requirements. Filters
|
|
|
+ are to be mounted 5 3/4"
|
|
|
+ upstream to the core in Typ.
|
|
|
+ the direction of airflow
|
|
|
+ LEFT VIEW entering the unit. RIGHT VIEW
|
|
|
+ MAoIRdFeLl:OCWAC2OXNINFIGURATION
|
|
|
+ DAravaiwlabilne gas sThyowpnein:dUimnenitsioDn idmraweinng.sion FRONT VIEW UNIT MOUNTING & APPLICATION
|
|
|
+ Version: MAY16 Can be mounted in any orientation. RA/EA airstream
|
|
|
+ can be switched with OA/FA airstream. Can be
|
|
|
+ CA-SERIES stacked three high.
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+6 RENEWAIRE.COM 1.800.627.4499
|
|
|
+CA3XIN Energy Recovery Module
|
|
|
+
|
|
|
+Door 33 7/8" Minimum 35" Minimum ABBREVIATION
|
|
|
+Swing Service Area Typ. Service Area Typ. EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ Door RA: Room Air to be exhausted
|
|
|
+ Swing FA: Fresh Air to inside
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ TOP VIEW 36" Overall Unit may be installed in any
|
|
|
+ 34 3/4" Case orientation.
|
|
|
+ 62" Overall NOTE:
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 62" Case
|
|
|
+ 5 3/4"
|
|
|
+ Typ.
|
|
|
+
|
|
|
+ 34 7/8" Overall 1 1/8"
|
|
|
+ 1 1/8" Typ.
|
|
|
+ Typ.
|
|
|
+ 34 7/8" Case
|
|
|
+
|
|
|
+ Note: Pleated, disposable 5 3/4" 14 1/8" X 24 1/8"
|
|
|
+ 20" X 20" X 2" filters are Typ. Typ.
|
|
|
+ provided for installation
|
|
|
+ LEFT VIEW and are interchangeable RIGHT VIEW
|
|
|
+MAoIRdFeLl:OCWAC3OXNINFIGURATION based on your airflow path
|
|
|
+DAravaiwlabilne gas sThyowpnein:dUimnenitsioDn idmraweinng.sion requirements. Filters are to UNIT MOUNTING & APPLICATION
|
|
|
+Version: MAY16 be mounted upstream to Can be mounted in any orientation. RA/EA airstream
|
|
|
+ the core in the direction of can be switched with OA/FA airstream. Can be
|
|
|
+ airflow entering the unit. stacked three high.
|
|
|
+
|
|
|
+ FRONT VIEW
|
|
|
+ CA4XIN Energy Recovery Module
|
|
|
+
|
|
|
+ 33 7/8" Minimum 35" Minimum ABBREVIATION
|
|
|
+ Service Area Typ. Service Area Typ. EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ Door Door RA: Room Air to be exhausted
|
|
|
+ Swing Swing FA: Fresh Air to inside
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ Unit may be installed in any
|
|
|
+ orientation.
|
|
|
+ NOTE:
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ TOP VIEW
|
|
|
+
|
|
|
+ 81 5/8" Overall 36" 81 5/8" Case
|
|
|
+ Overall 7 5/8" Typ.
|
|
|
+
|
|
|
+ 34 7/8"
|
|
|
+ Case
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 7 34 7/8" Overall 34 7/8" 1 1/8" Typ.
|
|
|
+ Case
|
|
|
+
|
|
|
+ Note: Pleated, disposable 1 1/8" 7 5/8" 14 1/8" X 32 1/8"
|
|
|
+ 20" X 20" X 2" filters are Typ. Typ. Typ.
|
|
|
+ provided for installation
|
|
|
+ LEFT VIEW and are interchangeable RIGHT VIEW
|
|
|
+ MAoIRdFeLl:OCWAC4OXNINFIGURATION based on your airflow path
|
|
|
+ DAravaiwlabilne gas sThyowpnein:dUimnenitsioDn idmraweinng.sion requirements. Filters are to UNIT MOUNTING & APPLICATION
|
|
|
+ Version: MAY16 be mounted upstream to Can be mounted in any orientation. RA/EA airstream
|
|
|
+ the core in the direction of can be switched with OA/FA airstream. Can be
|
|
|
+ CA-SERIES airflow entering the unit. stacked three high.
|
|
|
+
|
|
|
+ FRONT VIEW
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+ CA OUTDOOR Energy Recovery Module
|
|
|
+
|
|
|
+ ROOFTOP UNITS SPECIFICATIONS
|
|
|
+ Modular Cabinets
|
|
|
+ Ventilation Type:
|
|
|
+ Static plate, heat and humidity transfer Insulation:
|
|
|
+ One inch, high density, FSK faced, fiberglass
|
|
|
+ Standard Features:
|
|
|
+ Insulated sheet metal cabinets with energy Options:
|
|
|
+ Double wall construction
|
|
|
+ exchange cores and filters. Exterior paint - white, custom colors
|
|
|
+ Blower not included and must be specified to
|
|
|
+ Accessories:
|
|
|
+ meet job requirements. Roof curb - standard 14"
|
|
|
+ Filters - MERV 13, 2" (shipped loose)
|
|
|
+
|
|
|
+xs.xlsx Thermal PerfoCrhmaratCnhcaerRt atings G5 2015.2.xlsx Description 2 CoresCA(I2OXMRT) CA3XRT CA4XRT
|
|
|
+
|
|
|
+ Typical Airflow 500-2,200 750-3,300 1,000-4,400
|
|
|
+ Range CFM
|
|
|
+ Two L125-G5 Three L125-G5 Four L125-G5
|
|
|
+ Download specification at: AHRI 1060 Certified Core 55 1/2" L x 43 1/4" W x 55 1/2" L x 63 1/2" W x 55 1/2" L x 83 1/4" W x
|
|
|
+ renewaire.com/specifications
|
|
|
+ Unit Dimensions 42 1/4" H 42 1/2" H 42 1/4" H
|
|
|
+ & Weight 250-329 lbs. 377-482 lbs. 462-593 lbs.
|
|
|
+ 63" L x 47" W x 48" H 60" L x 90" W x 48" H 60" L x 90" W x 48" H
|
|
|
+ Max. Shipping Dimensions
|
|
|
+ & Weight (on pallet) 400 lbs. 590 lbs. 700 lbs.
|
|
|
+
|
|
|
+ Filters: MERV 8: Total qty. 4 Total qty. 6 Total qty. 8
|
|
|
+ Thermal Performance Ratings G5 2015.2.xls2x0" x 20" x 2" 3 Cores (IOM)
|
|
|
+
|
|
|
+ AIRFLOW PERFORMANCE CORE PERFORMANCE
|
|
|
+
|
|
|
+ AirfloAwirf(loCwFM(C)FM) Airflow (CFM)
|
|
|
+
|
|
|
+ Static Presure 2.0 2.0 500 1000 1500 2000
|
|
|
+ StDartiocp (Pirne.swu.rge)1.5 1.5 90% 3000 3500
|
|
|
+ Drop (in.w.g) Effectiveness (%)
|
|
|
+ 1.0 1.0 Thermal Performance Ratings G5 2015.2.xlsx 70% 4 Cores (IOM)
|
|
|
+
|
|
|
+ 0.5 0.5 50%
|
|
|
+
|
|
|
+ 0.0 0.0 CA2XRT
|
|
|
+ 0 0 1000 10002000 20003000 30004000 4000
|
|
|
+ Note: Airflow performance includes effect of clean, 30%
|
|
|
+ standard filter supplied with unit.
|
|
|
+ Airflow (CFM)
|
|
|
+
|
|
|
+ Effectiveness (%) 500 1000 1500 2000 2500
|
|
|
+ 90%
|
|
|
+
|
|
|
+ 70%
|
|
|
+
|
|
|
+ 50%
|
|
|
+
|
|
|
+ CA3XRT
|
|
|
+
|
|
|
+ 30%
|
|
|
+
|
|
|
+ Airflow (CFM)
|
|
|
+
|
|
|
+ 1000 2000 3000 4000
|
|
|
+ 90%
|
|
|
+ Effectiveness (%)
|
|
|
+ 70%
|
|
|
+
|
|
|
+ 50%
|
|
|
+
|
|
|
+ CA4XRT
|
|
|
+
|
|
|
+ 30%
|
|
|
+ At AHRI 1060 standard conditions.
|
|
|
+ See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+ 8 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ CA2XRT Energy Recovery Module
|
|
|
+
|
|
|
+ Alternate Hood Location. CURB CA2XRT ABBREVIATIONS
|
|
|
+ If hood location switched, EA: Exhaust Air to outside
|
|
|
+ plug existing mounting holes OA: Outside Air intake
|
|
|
+ on opposite side of unit to RA: Room Air to be exhausted
|
|
|
+ prevent leakage. FA: Fresh Air to inside
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ 24" X 10" CL 20 1/4" 33 7/8" Minimum 37 5/8" O.D. Unit must be installed in orientation
|
|
|
+ Floor Opening Typ. Service Area shown.
|
|
|
+ A A NOTE
|
|
|
+ Typ. 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ 55 1/2" Overall 4"Door FA 28 7/8" I.D. NEAREST EIGHTH OF AN INCH.
|
|
|
+ 35 1/2" Case Typ.Swing 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ CL 25 7/8" TO CHANGE WITHOUT NOTICE.
|
|
|
+ 35 1/2" Minimum
|
|
|
+ Service Area RA CURB CROSS-SECTION A-A (TYP.)
|
|
|
+ 32 5/8" O.D.
|
|
|
+ 5 3/4" 1 7/8" 1 1/2" X 1/4" 1 7/8"
|
|
|
+ 12 5/8" I.D. Neoprene Gasket
|
|
|
+ CL 9 1/2" 26 1/4" I.D.
|
|
|
+ 33 7/8" I.D. 3/4" X 3 1/2" 14"
|
|
|
+ Wooden Nailer
|
|
|
+ TOP VIEW
|
|
|
+ TOP VIEW 3"
|
|
|
+
|
|
|
+ 43 1/4" Overall SECTION A-A
|
|
|
+ 41 3/4" Case
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 9 2" OA Hood can be 35 3/4" 24 1/8"
|
|
|
+ 37 5/8" Typ. mounted to either Lifting Lugs Typ.
|
|
|
+ Lifting Lugs
|
|
|
+ side of unit
|
|
|
+
|
|
|
+ 42 1/4" Overall 25 1/4" 10" Typ.
|
|
|
+ 39 1/8" Case
|
|
|
+ Pressure Ports Typ.
|
|
|
+ (4) Typ.
|
|
|
+
|
|
|
+ 8 1/8" Note: Pleated, disposable 20" X 20" X Lower side pan inlets/outlets
|
|
|
+ Typ. 2" filters are provided for installation are patched with
|
|
|
+ Floor pan inlets/outlets are open by and are interchangeable based on removable insulated pans.
|
|
|
+ default; These can be patched from your airflow path requirements. Filters
|
|
|
+ inside the unit with removeable insulated are to be mounted upstream to the RIGHT VIEW
|
|
|
+ pans from the side openings, if unused. core in the direction of airflow
|
|
|
+ entering the unit. UNIT MOUNTING & APPLICATION
|
|
|
+ LEFT VIEW Must be mounted as shown. Duct configuration is
|
|
|
+ FRONT VIEW field convertible. Weather hood can be moved in
|
|
|
+ DMroaAAvdwIaRielaiFnbl:LlgeCOaTsAWys2hpoCXewROn: TiUNn ndFimiItGeDnUsiimRonAedTrnaIwOsiinoNgn. the field. RA/EA airstream can be switched with
|
|
|
+ Version: MAY16 OA/FA airstream.
|
|
|
+
|
|
|
+ CA-SERIES
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+10 RENEWAIRE.COM 1.800.627.4499
|
|
|
+CA3XRT Energy Recovery Module
|
|
|
+
|
|
|
+ Alternate Hood Location. If hood location ABBREVIATIONS
|
|
|
+ switched, plug existing mounting holes on EA: Exhaust Air to outside
|
|
|
+ opposite side of unit to prevent leakage. OA: Outside Air intake
|
|
|
+ RA: Room Air to be exhausted
|
|
|
+ 36" X 10" CURB CA3XRT FA: Fresh Air to inside
|
|
|
+ Floor INSTALLATION ORIENTATION
|
|
|
+ CL 30 1/4" 33 3/4" Minimum 57 1/2" O.D. Unit must be installed in orientation
|
|
|
+ Opening Typ. Service Area shown.
|
|
|
+ Typ. 53 3/4" I.D. NOTE
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ 5" A A DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ Typ. NEAREST EIGHTH OF AN INCH.
|
|
|
+ 35 1/2" Case Door FA 28 7/8" I.D. 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ 35 1/2" MinimumSwing TO CHANGE WITHOUT NOTICE.
|
|
|
+55 1/2" Overall CL 26" Service Area
|
|
|
+ 32 5/8" RA
|
|
|
+ O.D.
|
|
|
+ CURB CROSS-SECTION A-A (TYP.)
|
|
|
+
|
|
|
+ CL 9 1/2" 9 5/8" 38 1/4" I.D. 12 3/8" 1 1/2" X 1/4" 1 7/8"
|
|
|
+ I.D. Neoprene Gasket
|
|
|
+
|
|
|
+ 1 7/8"
|
|
|
+
|
|
|
+ TOP VIEW 3/4" X 3 1/2" 14"
|
|
|
+ Wooden Nailer
|
|
|
+ TOP VIEW
|
|
|
+ 3"
|
|
|
+
|
|
|
+ SECTION A-A
|
|
|
+
|
|
|
+ 63 3/8" Overall
|
|
|
+
|
|
|
+ 2" 61 1/2" Case OA Hood can be 35 3/4" 36 1/8" Typ. 10" Typ.
|
|
|
+ Typ. mounted to either Lifting Lugs
|
|
|
+ 57 5/8" Lifting Lugs
|
|
|
+ side of unit
|
|
|
+
|
|
|
+ Pressure Ports 42 1/4" Overall 24 7/8" Typ.
|
|
|
+ (4) Typ. 39 1/4" Case
|
|
|
+
|
|
|
+ 12" Note: Pleated, disposable 20" X 20" X 2" Lower side pan inlets/outlets
|
|
|
+ Typ. filters are provided for installation and are patched with
|
|
|
+ are interchangeable based on your removable insulated pans.
|
|
|
+ Floor pan inlets/outlets are open by airflow path requirements. Filters are
|
|
|
+ default; These can be patched from to be mounted upstream to the core RIGHT VIEW
|
|
|
+ inside the unit with removeable insulated in the direction of airflow entering the
|
|
|
+ pans from the side openings, if unused. unit. UNIT MOUNTING & APPLICATION
|
|
|
+ Must be mounted as shown. Duct configuration is
|
|
|
+ LEFT VIEW FRONT VIEW field convertible. Weather hood can be moved in
|
|
|
+ the field. RA/EA airstream can be switched with
|
|
|
+MDroadwAAeviInalR:ilgaFCbLlTeAyOa3psWXsehRo:CTwUOnniNnitdFiDmIGiemnUsieRonnAdsTriaoIwOninNg. OA/FA airstream.
|
|
|
+Version: MAY16
|
|
|
+ CA4XRT Energy Recovery Module
|
|
|
+
|
|
|
+ 48" X 10" Alternate Hood Location. If hood location ABBREVIATIONS
|
|
|
+ Floor Openings switched, plug existing mounting holes on EA: Exhaust Air to outside
|
|
|
+ opposite side of unit to prevent leakage. OA: Outside Air intake
|
|
|
+ Typ. RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+
|
|
|
+ CL 40 1/8" 33 7/8" Minimum 35 1/2" Minimum CURB CA4XRT 1 7/8" INSTALLATION ORIENTATION
|
|
|
+ Typ. Service Area Service Area Unit must be installed in orientation
|
|
|
+ 12 5/8" 50 1/2" I.D. shown.
|
|
|
+ I.D.
|
|
|
+ 35 1/2" Case Door FA 28 7/8" I.D. NOTE
|
|
|
+ CL 26" RA 32 5/8" O.D. 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+
|
|
|
+ Swing A A 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ CL 9 1/2" 13 3/8" CURB CROSS-SECTION A-A (TYP.)
|
|
|
+
|
|
|
+ 73 3/8" I.D. 1 1/2" X 1/4" 1 7/8"
|
|
|
+ 77 1/8" O.D.
|
|
|
+ Neoprene Gasket
|
|
|
+ TOP VIEW
|
|
|
+ 3/4" X 3 1/2" 14"
|
|
|
+ OA Hood can be Wooden Nailer
|
|
|
+ TOP VIEW mounted to either
|
|
|
+ side of unit
|
|
|
+ 3"
|
|
|
+ 55 1/2" Overall
|
|
|
+ 30 5/8" SECTION A-A
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 11 83" Overall 2" Lifting Lugs 48 1/8" Typ. 10" Typ.
|
|
|
+ 81 3/8" Case Typ.
|
|
|
+ 77 1/4" Lifting Lugs
|
|
|
+
|
|
|
+ 5 7/8" 24 7/8" Typ.
|
|
|
+ Typ.
|
|
|
+ 42 1/8" Overall
|
|
|
+ 39 1/4" Case
|
|
|
+ 16" Pressure Ports Lower side pan inlets/outlets
|
|
|
+ Typ. (4) Typ. are patched with
|
|
|
+ removable insulated pans.
|
|
|
+ Floor pan inlets/outlets are open by Note: Pleated, disposable
|
|
|
+ default; These can be patched from 20" X 20" X 2" filters are RIGHT VIEW
|
|
|
+ inside the unit with removeable insulated provided for installation and
|
|
|
+ pans from the side openings, if unused. are interchangeable based UNIT MOUNTING & APPLICATION
|
|
|
+ on your airflow path Must be mounted as shown. Duct configuration is
|
|
|
+ LEFT VIEW requirements. Filters are to field convertible. Weather hood can be moved in
|
|
|
+ be mounted upstream to the field. RA/EA airstream can be switched with
|
|
|
+ AIRFLOW CONFIGURATION the core in the direction of OA/FA airstream.
|
|
|
+ airflow entering the unit.
|
|
|
+ MoAdvaeilalb:leCaAs s4hXowRnTin dimension drawing.
|
|
|
+ Drawing Type: Unit Dimension FRONT VIEW
|
|
|
+ Version: MAY16
|
|
|
+
|
|
|
+ CA-SERIES
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+ PA SERIES Energy Recovery Module
|
|
|
+
|
|
|
+ INDOOR UNIT SPECIFICATIONS
|
|
|
+ Unlimited Modular Panels
|
|
|
+
|
|
|
+ Ventilation Type: Insulation:
|
|
|
+ Static plate, heat and humidity transfer One inch, high density, FSK faced, fiberglass
|
|
|
+
|
|
|
+ Standard Features: Options:
|
|
|
+ Insulated sheet metal panels easily slide into Knockdown
|
|
|
+ Assembled on structural forklift base
|
|
|
+ receivers to enclose stacks of energy exchange
|
|
|
+ cores using unique patented design, US Patent Accessories:
|
|
|
+ 5,660,228 Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Individual PA-Series units can be joined together to
|
|
|
+As.Rxl.sxxlsx Catalog CChhaarrtt provide unlimited airflow capacities for larger air
|
|
|
+ handling systems.
|
|
|
+ Blower not included and must be specified to meet
|
|
|
+ job requirements.
|
|
|
+
|
|
|
+ Description PA6X PA8X PA9X PA12X
|
|
|
+
|
|
|
+ Typical Airflow 1,500-6,600 2,000-8,800 2,250-9,900 3,000-13,200
|
|
|
+ Range CFM
|
|
|
+
|
|
|
+ AHRI 1060 Six Eight Nine Twelve
|
|
|
+ Certified Core L125-G5 L125-G5 L125-G5 L125-G5
|
|
|
+
|
|
|
+ Unit Dimensions 73 1/2" L x 37 1/4" W 73 1/2" L x 37 1/4" W 109 1/2" L x 37 1/4" W 109 1/2" L x 37 1/4" W
|
|
|
+ & Weight
|
|
|
+ x 66 1/4" H x 86" H x 66 1/4" H x 86" H
|
|
|
+
|
|
|
+ Download specification at: 522-565 lbs. 650-700 lbs. 740-910 lbs. 936-1,000 lbs.
|
|
|
+ renewaire.com/specifications
|
|
|
+ Max. Shipping
|
|
|
+
|
|
|
+ Dimensions & 96" L x 47" W x 75" H 96" L x 47" W x 92" H 124" L x 48" W x 75" H 124" L x 48" W x 95" H
|
|
|
+
|
|
|
+ Weight (on pallet, 700 lbs. 850 lbs. 1,100 lbs. 1,200 lbs.
|
|
|
+
|
|
|
+ assembled only)
|
|
|
+
|
|
|
+ Filters MERV 8: Total qty. 12 Total qty. 16 Total qty. 18 Total qty. 24
|
|
|
+ 20" x 20" x 2"
|
|
|
+
|
|
|
+ AIRFLOW PERFORMANCE
|
|
|
+Ratings G5 2015.2.xlsx 6 Cores (IOThMe)rmal Performance Ratings G5 2015.2.xlsx 9 Cores (IOM)
|
|
|
+
|
|
|
+ 2.5 AirfloAwirf(lCowFM(C) FM)
|
|
|
+
|
|
|
+ Static Pressure 2.0
|
|
|
+ StaDtriocpP(rien.suw.rge.)2.0
|
|
|
+ Drop (in.w.g)
|
|
|
+ 1.5
|
|
|
+ 1.5
|
|
|
+
|
|
|
+ 1.0 1.0
|
|
|
+
|
|
|
+ 0.5 0.5
|
|
|
+
|
|
|
+Ratings G5 2015.2.xlsx0.0 0.0 8 Cores (IOThMe)rmal Performance Ratings G5 2015.2.xlsx 12 Cores (IOM)
|
|
|
+
|
|
|
+ 0 0 3000 10006000 2000 90003000120040000
|
|
|
+
|
|
|
+ Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ CORE PERFORMANCE
|
|
|
+
|
|
|
+ Airflow (CFM) Airflow (CFM)
|
|
|
+
|
|
|
+ Effectiveness (%) 1000 2000 3000 4000 5000 6000 7000 1500 3500 5500 7500 9500
|
|
|
+ 90% 90%
|
|
|
+ Effectiveness (%)
|
|
|
+ 70% 70%
|
|
|
+
|
|
|
+ 50% 50%
|
|
|
+
|
|
|
+ PA6X PA9X
|
|
|
+
|
|
|
+ 30% 30%
|
|
|
+
|
|
|
+ Airflow (CFM) Airflow (CFM)
|
|
|
+
|
|
|
+ 2000 4000 6000 8000 3000 6000 9000 12000 15000
|
|
|
+ 90% 90%
|
|
|
+ Effectiveness (%) Effectiveness (%)
|
|
|
+ 70% 70%
|
|
|
+
|
|
|
+ 50% 50%
|
|
|
+
|
|
|
+ PA8X PA12X
|
|
|
+
|
|
|
+ 30% 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+12 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ PA6X Energy Recovery Module ABBREVIATION
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ Filters to be placed on the OA: Outside Air intake
|
|
|
+ upstream side of the cores, RA: Room Air to be exhausted
|
|
|
+ depending on airflow FA: Fresh Air to inside
|
|
|
+ arrangement chosen. INSTALLATION ORIENTATION
|
|
|
+ Filters are 2" X 20" X 20" Unit must be installed in orientation
|
|
|
+ pleated disposable. shown.
|
|
|
+ 73 3/8" Overall NOTE:
|
|
|
+ 73 1/8" Case 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ TOP VIEW 71 5/8" Minimum AVAILABLE AIRFLOW
|
|
|
+ Service Area ARRANGEMENTS
|
|
|
+ 37 1/4" Overall (SIDE VIEW)
|
|
|
+ 35" Case
|
|
|
+ 2
|
|
|
+
|
|
|
+ 1 2 1 2
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 13 2 1 2 1
|
|
|
+
|
|
|
+ 22 1/2" Minimum Arrangement 1 Arrangement 2
|
|
|
+ Service Area
|
|
|
+ 66 1/8" Overall 1 1 1 1
|
|
|
+ 59 3/4" Case
|
|
|
+ 28" Typ. 34 3/8" Typ. 2 2 2 2
|
|
|
+
|
|
|
+ Arrangement 3 Arrangement 4
|
|
|
+
|
|
|
+ 5" Performance Derating:
|
|
|
+
|
|
|
+ Airflow Arrangements 3 & 4 result in lower energy transfer.
|
|
|
+
|
|
|
+ Reduce sensible effectiveness by 2 percentage points.
|
|
|
+
|
|
|
+ LEFT VIEW PAIN PAIN FRONT VIEW PAIN PAIN Reduce total effectiveness by 1 percentage point.
|
|
|
+
|
|
|
+ AIRFLOW CONFIGURATION 1 2 3 4 UNIT MOUNTING & APPLICATION
|
|
|
+
|
|
|
+ MoAdvaeilalb:lePaAs s6hoXwn: RA/OA RA/OA RA/OA EA/FA RA/OA EA/FA RA/OA EA/FA Must be mounted as shown. RA/EA airstream can
|
|
|
+ EA/FA RA/OA EA/FA be switched with OA/FA airstream. Knockdown can
|
|
|
+ Drawing Type: Unit Dimension EA/FA EA/FA RA/OA EA/FA RA/OA be field assembled for multiple duct configurations.
|
|
|
+ Multiple cabinets can be aligned for unlimited airflow.
|
|
|
+ Version: AUG18
|
|
|
+
|
|
|
+ PA-SERIES
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+14 RENEWAIRE.COM 1.800.627.4499
|
|
|
+PA8X Energy Recovery Module ABBREVIATION
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ Filters to be placed on the OA: Outside Air intake
|
|
|
+ upstream side of the cores, RA: Room Air to be exhausted
|
|
|
+ depending on airflow FA: Fresh Air to inside
|
|
|
+ arrangement chosen. INSTALLATION ORIENTATION
|
|
|
+ Filters are 2" X 20" X 20" Unit must be installed in orientation
|
|
|
+ pleated disposable. shown.
|
|
|
+73 3/8" Overall NOTE:
|
|
|
+ 73 1/8" Case 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ TOP VIEW 71 5/8" Minimum AVAILABLE AIRFLOW
|
|
|
+ Service Area ARRANGEMENTS
|
|
|
+ 37 1/4" Overall (SIDE VIEW)
|
|
|
+ 35" Case
|
|
|
+ 1 2 1 2
|
|
|
+
|
|
|
+ 22 1/2" Minimum 2 1 2 1
|
|
|
+ Service Area
|
|
|
+ 85 7/8" Overall Arrangement 1 Arrangement 2
|
|
|
+ 79 1/2" Case
|
|
|
+ 1 1 1 1
|
|
|
+
|
|
|
+ 37" Typ. 45 1/8" Typ. 2 2 2 2
|
|
|
+
|
|
|
+ Arrangement 3 Arrangement 4
|
|
|
+
|
|
|
+ 5" Performance Derating:
|
|
|
+
|
|
|
+ Airflow Arrangements 3 & 4 result in lower energy transfer.
|
|
|
+
|
|
|
+ Reduce sensible effectiveness by 2 percentage points.
|
|
|
+
|
|
|
+ LEFT VIEW PAIN PAFINRONT VIEW PAIN PAIN Reduce total effectiveness by 1 percentage point.
|
|
|
+
|
|
|
+AIRFLOW CONFIGURATION 1 2 3 4 UNIT MOUNTING & APPLICATION
|
|
|
+
|
|
|
+MoAdvaeilalb:lePaAs s8hoXwn: RA/OA RA/OA RA/OA EA/FA RA/OA EA/FA RA/OA EA/FA Must be mounted as shown. RA/EA airstream can
|
|
|
+ EA/FA RA/OA EA/FA be switched with OA/FA airstream. Knockdown can
|
|
|
+Drawing Type: Unit Dimension EA/FA EA/FA RA/OA EA/FA RA/OA be field assembled for multiple duct configurations.
|
|
|
+ Multiple cabinets can be aligned for unlimited airflow.
|
|
|
+Version: AUG18
|
|
|
+ PA9X Energy Recovery Module ABBREVIATION
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ Filters to be placed on the OA: Outside Air intake
|
|
|
+ upstream side of the cores, RA: Room Air to be exhausted
|
|
|
+ depending on airflow FA: Fresh Air to inside
|
|
|
+ arrangement chosen. INSTALLATION ORIENTATION
|
|
|
+ Filters are 2" X 20" X 20" Unit must be installed in orientation
|
|
|
+ pleated disposable. shown.
|
|
|
+ 109 3/8" Overall NOTE:
|
|
|
+ 109 1/4" Case 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ TOP VIEW AVAILABLE AIRFLOW
|
|
|
+ ARRANGEMENTS
|
|
|
+ 37 1/4" (SIDE VIEW)
|
|
|
+ Overall
|
|
|
+ 35" Case 107 3/4" Minimum 1 2 1 2
|
|
|
+ Service Area
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 15 2 1 2 1
|
|
|
+
|
|
|
+ 31 1/8" Arrangement 1 Arrangement 2
|
|
|
+ Minimum
|
|
|
+ 66 1/8" Overall 1 1 1 1
|
|
|
+ 59 3/4" Case Service
|
|
|
+ Area
|
|
|
+
|
|
|
+ 5" 2 2 2 2
|
|
|
+ 28" Typ.
|
|
|
+ Arrangement 3 Arrangement 4
|
|
|
+ 34 3/8" Typ.
|
|
|
+ Performance Derating:
|
|
|
+
|
|
|
+ Airflow Arrangements 3 & 4 result in lower energy transfer.
|
|
|
+
|
|
|
+ Reduce sensible effectiveness by 2 percentage points.
|
|
|
+
|
|
|
+ LEFT VIEW PAIN FRPOAINNT VIEW PAIN PAIN Reduce total effectiveness by 1 percentage point.
|
|
|
+
|
|
|
+ AIRFLOW CONFIGURATION 1 2 3 4 UNIT MOUNTING & APPLICATION
|
|
|
+
|
|
|
+ MoAdvaeilalb:lePaAs s9hoXwn: RA/OA RA/OA RA/OA EA/FA RA/OA EA/FA RA/OA EA/FA Must be mounted as shown. RA/EA airstream can
|
|
|
+ EA/FA RA/OA EA/FA be switched with OA/FA airstream. Knockdown can
|
|
|
+ Drawing Type: Unit Dimension EA/FA EA/FA RA/OA EA/FA RA/OA be field assembled for multiple duct configurations.
|
|
|
+ Multiple cabinets can be aligned for unlimited airflow.
|
|
|
+ Version: AUG18
|
|
|
+
|
|
|
+ PA-SERIES
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+16 RENEWAIRE.COM 1.800.627.4499
|
|
|
+PA12X Energy Recovery Module ABBREVIATION
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ Filters to be placed on the OA: Outside Air intake
|
|
|
+ upstream side of the cores, RA: Room Air to be exhausted
|
|
|
+ depending on airflow FA: Fresh Air to inside
|
|
|
+ arrangement chosen. INSTALLATION ORIENTATION
|
|
|
+ Filters are 2" X 20" X 20" Unit must be installed in orientation
|
|
|
+ pleated disposable. shown.
|
|
|
+109 3/8" Overall NOTE:
|
|
|
+ 109 1/4" Case 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+TOP VIEW AVAILABLE AIRFLOW
|
|
|
+ ARRANGEMENTS
|
|
|
+ 37 1/4" (SIDE VIEW)
|
|
|
+ Overall
|
|
|
+ 35" Case 107 3/4" Minimum 1 2 1 2
|
|
|
+ Service Area
|
|
|
+
|
|
|
+ 2 1 2 1
|
|
|
+
|
|
|
+ 22 1/2" Arrangement 1 Arrangement 2
|
|
|
+ Minimum
|
|
|
+
|
|
|
+ Service
|
|
|
+ Area
|
|
|
+
|
|
|
+ 85 7/8" Overall 1 1 1 1
|
|
|
+ 79 1/2" Case
|
|
|
+ 5" 2 2 2 2
|
|
|
+ 36 7/8"
|
|
|
+ Arrangement 3 Arrangement 4
|
|
|
+ Typ.
|
|
|
+ 45 1/8" Typ.
|
|
|
+
|
|
|
+LEFT VIEW PAIN FRONTPAINVIEW PAIN Performance Derating:
|
|
|
+ Airflow Arrangements 3 & 4 result in lower energy transfer.
|
|
|
+
|
|
|
+ Reduce sensible effectiveness by 2 percentage points.
|
|
|
+ PAIN Reduce total effectiveness by 1 percentage point.
|
|
|
+
|
|
|
+MDroadweAAinvlI:aRgilPaFbATLleyO1aps2WesXh:oCwUOnn: NitFDIGimUReAnTsIiOoNn 1 RA/OA RA/OA 2 RA/OA 3 RA/OA 4 UNIT MOUNTING & APPLICATION
|
|
|
+ EA/FA RA/OA RA/OA
|
|
|
+ RA/OA EA/FA EA/FA EA/FA Must be mounted as shown. RA/EA airstream can
|
|
|
+ EA/FA EA/FA EA/FA be switched with OA/FA airstream. Knockdown can
|
|
|
+ EA/FA RA/OA be field assembled for multiple duct configurations.
|
|
|
+Version: AUG18 Multiple cabinets can be aligned for unlimited airflow.
|
|
|
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 17
|
|
|
+CERTIFICATIONS & PERFORMANCE
|
|
|
+
|
|
|
+AHRI 1060
|
|
|
+
|
|
|
+CERTIFIED PERFORMANCE
|
|
|
+
|
|
|
+Energy recovery component certified in accordance with AHRI Standard 1060-2013.
|
|
|
+Actual performance in packaged equipment may vary.
|
|
|
+
|
|
|
+ AHRI-1060 Certified Performance - Model Number L125-G5
|
|
|
+
|
|
|
+ Type Tilt Angle Nominal Airflow Pressure Drop
|
|
|
+ Plate N/A
|
|
|
+ 100% - 750 SCFM 0.65 in. H20
|
|
|
+ Leakage Ratings 75% - 563 SCFM
|
|
|
+
|
|
|
+ Thermal Effectiveness Ratings at 0" Pressure Differential
|
|
|
+
|
|
|
+ Pressure EATR OACF Purge Angle or Nominal Airflow Sensible Latent Total Net Net Net Net
|
|
|
+Differential Setting Airflow Sensible Latent Total
|
|
|
+-1 in. H20
|
|
|
+ 1.0% 1.00 N/A 750 Heating 70% 52% 64% 750 70% 52% 64%
|
|
|
+ 0 in. H20
|
|
|
+ CFM Cooling 70% 42% 53% CFM 70% 42% 53%
|
|
|
+ 1 in. H20
|
|
|
+ 0.0% 1.02 N/A
|
|
|
+
|
|
|
+ 563 Heating 74% 59% 69% 563 74% 59% 69%
|
|
|
+
|
|
|
+ 0.0% 1.05 N/A CFM Cooling 74% 49% 58% CFM 74% 49% 58%
|
|
|
+
|
|
|
+NOTE: SCFM = Standard Cubic Feet per Minute OACF = Outdoor Air Correction Factor EATR = Exhaust Air Transfer Ratio N/A = Not Applicable
|
|
|
+
|
|
|
+18 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ ORDERING & SUPPORT
|
|
|
+
|
|
|
+ CA & PA MODEL
|
|
|
+ CONFIGURATION GUIDE
|
|
|
+
|
|
|
+ Note: Not all options are available on every model.
|
|
|
+
|
|
|
+MODEL NUMBER J ------------ N
|
|
|
+
|
|
|
+DIGIT NUMBER 123 4 567 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
|
|
|
+
|
|
|
+ Digits 1 - 2: Model Digit 11: Wall Type (see Restriction 4)
|
|
|
+"CA-2X" = Cabinet Applied 2 Cores "S" = Single
|
|
|
+"CA-3X" = Cabinet Applied 3 Cores "D" = Double
|
|
|
+"CA-4X" = Cabinet Applied 4 Cores
|
|
|
+"PA-6X" = Panelized Applied 6 Cores Digit 24: Other Options (see Restriction 5, 6 & 7)
|
|
|
+"PA-8X" = Panelized Applied 8 Cores
|
|
|
+"PA-9X" = Panelized Applied 9 Cores "-" = None
|
|
|
+"PA12X" = Panelized Applied 12 Cores "K" = Knockdown
|
|
|
+ "A" = Assembled
|
|
|
+ Digits 7 - 8: Location (see Restriction 1) "W" = White Paint
|
|
|
+"IN" = Indoor "C" = Custom Paint
|
|
|
+"RT" = Rooftop "X" = Custom Unit
|
|
|
+
|
|
|
+ Digit 25: Safety Listing
|
|
|
+
|
|
|
+Digit 9: Forklift Base "N" = Non-Listed
|
|
|
+
|
|
|
+"-" = None (CA Models)
|
|
|
+"9" = Forklift Base (PA Models)
|
|
|
+
|
|
|
+Digit 10: Orientation (see Restrictions 2 & 3)
|
|
|
+
|
|
|
+"1" = Opposite-side Entry, Cross-flow
|
|
|
+"2" = Same-side Entry, Cross-flow
|
|
|
+"3" = Opposite-side Entry, Parallel-flow
|
|
|
+"4" = Same-side Entry, Parallel-flow
|
|
|
+"-" = Flexible Airflow
|
|
|
+
|
|
|
+*NOTES: Digits 12-23 are not used in these models.
|
|
|
+Digit 6 "J" = G5 Core Type
|
|
|
+
|
|
|
+Restrictions:
|
|
|
+ 1: Location Code "RT" only available with CA models.
|
|
|
+ 2: Orientation Code "-" only available on CA models & PA models with Flexible Packaging Code "K".
|
|
|
+ 3: Orientation Codes "1", "2", "3",& "4" only availble with PA models with Flexible Packaging Code "A".
|
|
|
+ 4: Wall Code "D" only available with CA models.
|
|
|
+ 5: Other Option Codes "W" & "C" only available with CA models.
|
|
|
+ 6: Other Option Code "W" only available with CA models with Location Code "RT".
|
|
|
+ 7: Other Option Codes "A" & "K" only available with PA models.
|
|
|
+
|
|
|
+ CA and PA MODELS
|
|
|
+ COMMERCIAL PRODUCT CODE CHART
|
|
|
+
|
|
|
+ For Technical Support E-mail: RenewaireSupport@renewaire.com
|
|
|
+ To Place an Order E-mail: RenewaireOrders@renewaire.com
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 19
|
|
|
+ORDERING & SUPPORT
|
|
|
+
|
|
|
+ INDOOR AIR QUALITY MATTERS
|
|
|
+
|
|
|
+ u Deficient IAQ is an EPA top-five health risk
|
|
|
+
|
|
|
+ u People spend 90% of their time indoors
|
|
|
+
|
|
|
+ u Indoor air can be 2-5 times and up to 100 times
|
|
|
+ more polluted than outdoor air
|
|
|
+
|
|
|
+BENEFITS OF INCREASED VENTILATION
|
|
|
+
|
|
|
+ BETTER IMPROVED INCREASED
|
|
|
+ HEALTH COGNITIVE PRODUCTIVITY
|
|
|
+ FUNCTION
|
|
|
+
|
|
|
+TECHNICAL/APPLICATIONS SUPPORT
|
|
|
+The goal of our technical-support team is to provide the BEST CUSTOMER SERVICE
|
|
|
+in the HVAC industry. You can count on our knowledgeable and seasoned staff for all your technical,
|
|
|
+application and service needs, and we’ll respond quickly and effectively to answer any of your questions.
|
|
|
+
|
|
|
+ CONTACT RENEWAIRE
|
|
|
+
|
|
|
+ PHONE: FOR TECHNICAL SUPPORT:
|
|
|
+ 1.800.627.4499 RenewaireSupport@renewaire.com
|
|
|
+
|
|
|
+ FAX: TO PLACE AN ORDER:
|
|
|
+ 608.221.2824 RenewaireOrders@renewaire.com
|
|
|
+
|
|
|
+20 RENEWAIRE.COM 1.800.627.4499
|
|
|
+RELEVANT RENEWAIRE
|
|
|
+
|
|
|
+EVERYWHERE TEMPERS THE AIR
|
|
|
+
|
|
|
+EVERY GEOGRAPHIC REGION Our ERVs moderate the extremes
|
|
|
+Our ERVs function perfectly across the world in every of outdoor supply-air temperature
|
|
|
+geographic region. and humidity year-round, providing
|
|
|
+ a sustainable solution for fresh air
|
|
|
+EVERY CLIMATE that feels like a perfect spring day.
|
|
|
+Our ERVs operate in every climate—from Alaska to
|
|
|
+Florida, and everywhere in between.
|
|
|
+
|
|
|
+EVERY PROJECT
|
|
|
+From massive skyscrapers to cozy residential homes,
|
|
|
+our ERVs can be used in every size project and in every
|
|
|
+code jurisdiction.
|
|
|
+
|
|
|
+APPLIED EVERYWHERE
|
|
|
+
|
|
|
+When indoor occupants breathe in unclean air, this harms their health and causes cognitive impairment. Our ERVs can
|
|
|
+provide cleaner and healthier indoor air for every type of building in the world, thus improving occupants’ wellbeing,
|
|
|
+while also reducing energy costs.
|
|
|
+
|
|
|
+RESIDENTIAL DAYCARE
|
|
|
+The increased airtightness of newer and remodeled Crowded daycare facilities breed deficient IAQ, thus
|
|
|
+homes is causing deficient IAQ, resulting in more health causing health problems for everyone—especially
|
|
|
+problems for indoor occupants. children who are more vulnerable.
|
|
|
+
|
|
|
+COMMERCIAL EDUCATION (LOWER AND HIGHER)
|
|
|
+As commercial buildings become more airtight, With students and teachers packed into tight classrooms,
|
|
|
+deficient IAQ is increasing and causing sickness, instances of deficient IAQ go up, resulting in academic
|
|
|
+absenteeism and decreased productivity. performance and test scores going down.
|
|
|
+
|
|
|
+H E A LT H C A R E GOVERNMENT
|
|
|
+The high occupant density of hospitals, nursing homes Aging and crowded government buildings result in
|
|
|
+and other healthcare facilities results in deficient IAQ deficient IAQ, which can impair worker performance
|
|
|
+and ensuing health problems for patients and staff alike. and productivity.
|
|
|
+
|
|
|
+RESTAURANTS/COFFEE SHOPS EVERY TYPE OF BUILDING
|
|
|
+The large volume of indoor occupants in restaurants Every type of building can benefit from the enhanced
|
|
|
+and coffee shops causes deficient IAQ and subsequent IAQ generated by RenewAire ERVs, including
|
|
|
+health problems. veterinary clinics, nail salons and manufacturing
|
|
|
+ facilities, among others.
|
|
|
+RETAIL
|
|
|
+The high level of foot traffic in retail stores leads
|
|
|
+to deficient IAQ and the potential sickness of shoppers,
|
|
|
+which can negatively impact sales.
|
|
|
+ RENEWAIRE EVERYWHERE LIT113_00 (01/19)
|
|
|
+
|
|
|
+ RenewAire ERVs can be applied everywhere across all
|
|
|
+ commercial, educational, institutional, light industrial
|
|
|
+
|
|
|
+ and residential buildings. Our technology excels in every
|
|
|
+ geographic region, every climate, and every size project.
|
|
|
+
|
|
|
+Member of the S&P Group
|
|
|
+Family of Brands
|
|
|
+ERV
|
|
|
+ EV450 & HE SERIES
|
|
|
+
|
|
|
+ COMMERCIAL ERV CATALOG
|
|
|
+
|
|
|
+JANUARY 2019
|
|
|
+
|
|
|
+RENEWAIRE.COM | 800.627.4499
|
|
|
+BECAUSE INDOOR
|
|
|
+
|
|
|
+AIR QUALITY MATTERS
|
|
|
+
|
|
|
+As buildings become more airtight due to better application of ERV technologies. Deficient IAQ is a
|
|
|
+construction methodologies, the need for increased serious problem, especially considering:
|
|
|
+and balanced ventilation is critical. Without it, internally u On average, Americans spend 90% of their time indoors
|
|
|
+generated contaminants accumulate and cause deficient u The EPA found that indoor air may be 2-5 times—and
|
|
|
+indoor air quality (IAQ), which leads to significant
|
|
|
+health and cognitive problems for occupants. Industry occasionally greater than 100 times—more polluted
|
|
|
+standards are changing to combat deficient IAQ, and than outdoor air
|
|
|
+codes that adopt these new standards are driving the u The EPA ranks indoor air pollutants as a top-five
|
|
|
+ environmental health risk to occupants
|
|
|
+
|
|
|
+HEALTH PRODUCTIVITY LEARNING
|
|
|
+MAT TERS MAT TERS MAT TERS
|
|
|
+
|
|
|
+ADVERSE EFFECTS ABOUT RENEWAIRE
|
|
|
+
|
|
|
+O F DEFICIENT IAQ For over 30 years, RenewAire has been
|
|
|
+ a pioneer in enhancing IAQ in commercial and
|
|
|
+Deficient IAQ has numerous adverse effects on the residential buildings of every size. This is achieved
|
|
|
+health and cognitive function of building occupants. while maximizing sustainability through our fifth-
|
|
|
+ generation, enthalpic-core, static-plate Energy
|
|
|
+ Health problems: Acute allergies, Recovery Ventilators (ERVs) that optimize energy
|
|
|
+ headaches, coughs, asthma, skin efficiency, lower capital costs via HVAC load
|
|
|
+ irritations and breathing difficulties, reduction and decrease operational expenses
|
|
|
+ as well as chronic illnesses such as by minimizing equipment needs, resulting
|
|
|
+ cancer, liver disease, kidney damage in significant energy savings. Our ERVs are
|
|
|
+ and nervous-system failure. competitively priced, simple to install, easy to use
|
|
|
+ and maintain, have a quick payback and enjoy the
|
|
|
+ Cognitive impairment: Studies by the industry’s best warranty with the lowest claims
|
|
|
+ Harvard School of Public Health and the due to long-term reliability. In 2010, RenewAire
|
|
|
+ Lawrence Berkeley National Laboratory joined the Soler & Palau (S&P) Ventilation Group,
|
|
|
+ found that carbon dioxide (CO )—an providing direct access to the latest in energy-
|
|
|
+ efficient air-moving technologies. For more
|
|
|
+ 2 information, visit: renewaire.com.
|
|
|
+
|
|
|
+ indoor air contaminant—negatively impacted
|
|
|
+ thinking and decision-making at levels
|
|
|
+ commonly found inside homes and buildings.
|
|
|
+ TABLE OF CONTENTS
|
|
|
+
|
|
|
+ TABLE OF
|
|
|
+
|
|
|
+CONTENTS
|
|
|
+
|
|
|
+EV450 - Light Commercial Unitary ERV HE2X - Commercial Unitary ERV
|
|
|
+
|
|
|
+MODEL TYPE CFM RANGE PAGE MODEL TYPE CFM RANGE PAGE
|
|
|
+EV450IN - STANDARD Indoor 200-540 CFM 4-5 HE2XINH - STANDARD Indoor 500-2,200 CFM 66-67
|
|
|
+ 6-7 HE2XINH - STANDARD BYPASS OPTION Indoor 500-2,200 CFM 68-69
|
|
|
+EV450IN - EC MOTOR OPTION Indoor 200-530 CFM HE2XINV - STANDARD Indoor 500-2,200 CFM 70-71
|
|
|
+EV450RT - STANDARD Rooftop 240-500 CFM 8-9, 12-13 HE2XINV - STANDARD BYPASS OPTION Indoor 500-2,200 CFM 72-73
|
|
|
+EV450RT - EC MOTOR OPTION Rooftop 200-510 CFM 10-13 HE2XRT - STANDARD Rooftop 500-2,000 CFM 74-76
|
|
|
+ HE2XRTC - STANDARD Rooftop 500-1,700 CFM 78-79
|
|
|
+
|
|
|
+HE1X - Light Commercial Unitary ERV
|
|
|
+
|
|
|
+MODEL TYPE CFM RANGE PAGE HE3X - Commercial Unitary ERV
|
|
|
+HE1XINH - STANDARD Indoor 250-925 CFM 14-15
|
|
|
+HE1XINH - EC MOTOR OPTION Indoor 250-1,100 CFM 16-17 MODEL TYPE CFM RANGE PAGE
|
|
|
+HE1XINH - STANDARD BYPASS OPTION Indoor 250-925 CFM 18-19 HE3XINH - STANDARD Indoor 750-3,300 CFM 80-81
|
|
|
+HE1XINH - EC MOTOR BYPASS OPTION Indoor 250-1,100 CFM 20-21 HE3XINH - STANDARD BYPASS OPTION Indoor 750-3,300 CFM 82-83
|
|
|
+HE1XINV - STANDARD Indoor 250-925 CFM 22-23 HE3XINV - STANDARD Indoor 750-3,300 CFM 84-85
|
|
|
+HE1XINV - EC MOTOR OPTION Indoor 250-1,100 CFM 24-25 HE3XINV - STANDARD BYPASS OPTION Indoor 750-3,300 CFM 86-87
|
|
|
+HE1XINV - STANDARD BYPASS OPTION Indoor 250-925 CFM 26-27 HE3XRT - STANDARD Rooftop 750-3,300 CFM 88-90
|
|
|
+HE1XINV - EC MOTOR BYPASS OPTION Indoor 250-1,100 CFM 28-29 HE3XRTC - STANDARD Rooftop 1,100-2,400 CFM 92-93
|
|
|
+HE1XRT - STANDARD Rooftop 250-870 CFM 30-32
|
|
|
+HE1XRT - EC MOTOR OPTION Rooftop 250-1,100 CFM 34-36 HE4X - Commercial Unitary ERV
|
|
|
+HE1XRTC - STANDARD Rooftop 500-900 CFM 38-39
|
|
|
+HE1XRTC - EC MOTOR OPTION Rooftop 500-1,100 CFM 40-41
|
|
|
+
|
|
|
+HE1.5X - Commercial Unitary ERV MODEL TYPE CFM RANGE PAGE
|
|
|
+ HE4XINH - STANDARD Indoor 1,000-4,400 CFM 94-95
|
|
|
+MODEL TYPE CFM RANGE PAGE HE4XINH - STANDARD BYPASS OPTION Indoor 1,000-4,400 CFM 96-97
|
|
|
+ 375-1,575 CFM 42-43 HE4XINV - STANDARD Indoor 1,000-4,400 CFM 98-99
|
|
|
+HE1.5XINH - STANDARD Indoor 375-1,575 CFM 44-45 HE4XINV - STANDARD BYPASS OPTION Indoor 1,000-4,400 CFM 100-101
|
|
|
+ 375-1,575 CFM 46-47 HE4XRT - STANDARD Rooftop 1,000-4,400 CFM 102-104
|
|
|
+HE1.5XINH - EC MOTOR OPTION Indoor 375-1,575 CFM 48-49 HE4XRTC - STANDARD Rooftop 2,500-3,900 CFM 106-107
|
|
|
+ 375-1,575 CFM 50-51
|
|
|
+HE1.5XINH - STANDARD BYPASS OPTION Indoor 375-1,575 CFM 52-53
|
|
|
+ 375-1,575 CFM 54-55
|
|
|
+HE1.5XINH - EC MOTOR BYPASS OPTION Indoor 375-1,575 CFM 56-57
|
|
|
+ 375-1,575 CFM 58-60
|
|
|
+HE1.5XINV - STANDARD Indoor 375-1,525 CFM 62-64
|
|
|
+
|
|
|
+HE1.5XINV - EC MOTOR OPTION Indoor HE6X - Commercial Unitary ERV
|
|
|
+
|
|
|
+HE1.5XINV - STANDARD BYPASS OPTION Indoor MODEL TYPE CFM RANGE PAGE
|
|
|
+ HE6XIN - STANDARD Indoor 1,500-6,500 CFM 108-109
|
|
|
+HE1.5XINV - EC MOTOR BYPASS OPTION Indoor HE6XIN - STANDARD BYPASS OPTION Indoor 1,500-6,500 CFM 110-111
|
|
|
+ HE6XRT - STANDARD Rooftop 1,500-6,500 CFM 112-113
|
|
|
+HE1.5XRT - STANDARD Rooftop
|
|
|
+
|
|
|
+HE1.5XRT - EC MOTOR OPTION Rooftop
|
|
|
+
|
|
|
+ABOUT RENEWAIRE 2-3 HE8X - Commercial Unitary ERV
|
|
|
+SPECIFICATIONS & DIMENSIONS 4-119
|
|
|
+OPTIONS & ACCESSORIES 121-139 MODEL TYPE CFM RANGE PAGE
|
|
|
+CERTIFICATIONS & PERFORMANCE HE8XIN - STANDARD Indoor 2,000-7,950 CFM 114-115
|
|
|
+ORDERING & SUPPORT 140 HE8XIN - STANDARD BYPASS OPTION Indoor 2,000-7,950 CFM 116-117
|
|
|
+ 141-144 HE8XRT - STANDARD Rooftop 2,000-7,950 CFM 118-119
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 1
|
|
|
+ ABOUT RENEWAIRE
|
|
|
+
|
|
|
+ R E N E WA I R E E R Vs
|
|
|
+
|
|
|
+ ACHIEVE SUSTAINABLE IAQ
|
|
|
+
|
|
|
+ RenewAire is a pioneer in enhancing IAQ while maximizing sustainability through enthalpic-core, static-plate Energy
|
|
|
+ Recovery Ventilators (ERVs) that optimize energy efficiency, lower costs by reducing HVAC loads and therefore
|
|
|
+ reduce environmental footprints. Our ERV technology preconditions incoming air with the otherwise-wasted energy
|
|
|
+ (heat and humidity) of the exhaust air going out—all while the airstreams are kept physically separate as certified by
|
|
|
+ the Air Conditioning, Heating and Refrigeration Institute (AHRI) for zero exhaust air transfer at normal balanced operating
|
|
|
+ conditions. As the pioneer of static-plate core technology in North America, RenewAire is the largest ERV producer in the USA.
|
|
|
+
|
|
|
+ OPTIMIZING OA COOLING SEASON RA OA HEATING SEASON RA
|
|
|
+ ENERGY EFFICIENCY
|
|
|
+ EFFICIENT EFFICIENT
|
|
|
+ Energy efficiency is optimized by preconditioning HEAT & HUMIDITY HEAT & HUMIDITY
|
|
|
+ the outside air coming in with the otherwise-wasted
|
|
|
+ heat and humidity of the exhaust air going out. This TRANSFER TRANSFER
|
|
|
+ exchange of energy moderates temperatures and moisture,
|
|
|
+ decreases HVAC equipment needs, drives operational EA FA EA FA
|
|
|
+ efficiencies and conserves energy.
|
|
|
+
|
|
|
+ REDUCING HVAC LOADS INSIDE OUTSIDE
|
|
|
+ Fresh Air Enters Stale Room Air Exits
|
|
|
+ RenewAire technology reduces HVAC loads during both winter and summer. In turn,
|
|
|
+ HVAC equipment size and needs can be decreased and furnaces and air conditioners Fixed Partition
|
|
|
+ can be smaller. This process ensures efficient operations and keeps both energy use and and Spacer Plates
|
|
|
+ costs low, while at the same time maintaining high-level IAQ.
|
|
|
+ (proprietary resin
|
|
|
+ and composite media) Outside Air
|
|
|
+
|
|
|
+ Stale Room Air
|
|
|
+
|
|
|
+ MINIMIZING ENVIRONMENTAL IMPACT
|
|
|
+
|
|
|
+ The combination of less energy used and HVAC loads being reduced conserves resources. Further, our Madison, WI plant
|
|
|
+ is 100% powered by renewable wind energy, and is one of the few buildings worldwide to be LEED and Green Globes
|
|
|
+ certified, as well as having achieved ENERGY STAR Building status. This commitment to sustainable manufacturing
|
|
|
+ minimizes our overall production and distribution environmental footprint.
|
|
|
+
|
|
|
+2
|
|
|
+ ABOUT RENEWAIRE
|
|
|
+
|
|
|
+WHY RENEWAIRE
|
|
|
+
|
|
|
+IS PREFERRED
|
|
|
+
|
|
|
+ BEST VALUE
|
|
|
+
|
|
|
+ u Priced competitively against other ERV models
|
|
|
+ u Due to competitive pricing and decreased costs, payback is short and ROI is maximized
|
|
|
+ u Contractors can pass these significant savings along to their customers
|
|
|
+
|
|
|
+ RELIABLE OPERATION
|
|
|
+
|
|
|
+ u Built-to-last ERVs have lifespans of 25+ years and operate consistently year-round in every extreme,
|
|
|
+ including frost-free performance in all but the most severe winter climates
|
|
|
+
|
|
|
+ u High-efficiency core operates dry in all conditions, meaning no condensate pans
|
|
|
+ u An industry-leading ten-year warranty for the static-plate core, two-year warranty for commercial
|
|
|
+
|
|
|
+ products and a five-year warranty for residential products
|
|
|
+ u Superior product quality results in paramount reliability and longevity
|
|
|
+
|
|
|
+ HIGHEST-QUALITY INDOOR AIR
|
|
|
+
|
|
|
+ u Stale indoor air is replaced with fresh, conditioned and filtered air from
|
|
|
+ the outside, resulting in Enhanced IAQ by removing harmful contaminants
|
|
|
+
|
|
|
+ u Airstreams do not mix and pollutants are not transferred across partition plates
|
|
|
+ u No biocide used; material does not promote biological growth
|
|
|
+ u Moderated temperatures and humidity maintain a comfortable indoor environment
|
|
|
+
|
|
|
+ OPTIMIZED ENERGY EFFICIENCY
|
|
|
+
|
|
|
+ u Efficient heat and humidity transfer recaptures up to 70-80% of the energy exhausted in the airstream
|
|
|
+ u Energy that’s otherwise wasted by conventional ventilation systems (such as bath fans) is reused,
|
|
|
+
|
|
|
+ thus dramatically reducing monthly operation costs
|
|
|
+ u Energy-efficient operation decreases HVAC loads, which cuts down on energy use and costs
|
|
|
+ u The hotter or colder the climate, the more energy is recovered
|
|
|
+
|
|
|
+ HIGHLY CERTIFIED
|
|
|
+
|
|
|
+ u See individual catalog submittal for certification details:
|
|
|
+ u UL u cUL u ETL u HVI u AHRI
|
|
|
+
|
|
|
+ 3
|
|
|
+SPECIFICATIONS & DIMENSIONS Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+EV 450IN
|
|
|
+ SPECIFICATIONS
|
|
|
+INDOOR UNIT
|
|
|
+ Ventilation Type: Accessories:
|
|
|
+Download specification at: Static plate, heat and humidity transfer Filters - MERV 13, 2" (shipped loose)
|
|
|
+renewaire.com/specifications Backdraft damper 10"
|
|
|
+ Typical Airflow Range: 200-540 CFM Wall cap 10" - galvanized, paintable galvanneal
|
|
|
+ Vibration isolation kit
|
|
|
+ AHRI 1060 Certified Core: One L85-G5 Hanging bracket kit
|
|
|
+ Transition kit 10" - round, qty. 2
|
|
|
+ Standard Features: Flange kit - rectangular 12" x 8", 2 flanges
|
|
|
+ Non-fused disconnect Solid state speed control kit - 115V, qty. 1,
|
|
|
+ 24 VAC transformer/relay package
|
|
|
+ Cross-core differential pressure ports 208-230V, qty. 1
|
|
|
+ Digital time clock - wall mount (TC7D-W),
|
|
|
+ Filters:
|
|
|
+ Total qty. 2, MERV 8: 14" x 20" x 2" in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ Unit Dimensions & Weight:
|
|
|
+ 54 1/2" L x 16 3/8" W x 36 3/4" H wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ 137-199 lbs., varies by option(s) IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): duct mount (IAQ-D)
|
|
|
+ 62" L x 42" W x 22" H Motion occupancy sensor/control -
|
|
|
+ 250 lbs.
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Motor(s), choice of: Smoke detector - duct mount (SD-D)
|
|
|
+ Qty. 1, 0.6 HP (standard single phase) Louver with 10" round duct connection -
|
|
|
+ Qty. 1, 0.5 HP (standard three phase)
|
|
|
+ 12" (W) x 12" (H)
|
|
|
+ Options: Electric duct heater - RH series (1-11.5 kW);
|
|
|
+ Qty. 1, Variable Speed/ECM - Direct Drive Motors
|
|
|
+ EK series (1–175 kW);
|
|
|
+ (see EV450IN EC Motor submittal) - designed for indoor ductwork installation only
|
|
|
+ 0.5 HP, 120V/1Ph/60HZ,
|
|
|
+ 0.5 HP, 208-230V/1Ph/60HZ
|
|
|
+ Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ enhanced, premium
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+ both airstreams
|
|
|
+ Double wall construction
|
|
|
+ Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ Note: Indirect Gas-Fired Duct Furnace is not available on the EV450IN.
|
|
|
+
|
|
|
+ELECTRICAL DATA UNIT PERFORMANCE
|
|
|
+
|
|
|
+ Thermal PeFrLfAormaAnMCmciinrep..sRatOinPvrgeDosMretceGvaucix5crt.rieoe2nn0t15.2.xlsx Airflow CFM EV450 (IOM) Watts
|
|
|
+ Phase ESP in H20
|
|
|
+HP Volts HZ 225 1P 3P
|
|
|
+ 375 1.25 335 181
|
|
|
+0.6 120 60 Single 7.2 9.0 15 420 0.89 464 333
|
|
|
+ 480 0.75 518 394
|
|
|
+0.6 208-230 60 Single 3.9-3.6 4.9 15 500 0.50 584 472
|
|
|
+ 540 0.43 600 491
|
|
|
+0.6 277 60 Single 3.5 4.4 15 0.25 640 540
|
|
|
+ 610
|
|
|
+0.5 208-230 60 Three 1.7-1.5 2.1 15
|
|
|
+
|
|
|
+0.5 460 60 Three 0.8 1.0 15
|
|
|
+
|
|
|
+ 575 0.00 690
|
|
|
+
|
|
|
+ Note: Watts is for the entire unit.
|
|
|
+ Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ CORE PERFORMANCE
|
|
|
+
|
|
|
+ Airflow (CFM)
|
|
|
+
|
|
|
+ Effectiveness (%) 200 300 400 500 600
|
|
|
+
|
|
|
+ 90%
|
|
|
+
|
|
|
+ 70%
|
|
|
+
|
|
|
+ 50%
|
|
|
+
|
|
|
+ 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+4 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ EV450IN Energy Recovery Ventilator Standaarrdd or EC Motor Option
|
|
|
+
|
|
|
+ 1 1/2" Typ. 47 1/8" Overall ABBREVIATIONS
|
|
|
+ (with Flanges) EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ 44 1/8" Case RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ Door Door INSTALLATION ORIENTATION
|
|
|
+ Swing Swing Unit may be installed in any orientation.
|
|
|
+ NOTE
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 14 1/4" Minimum 44 1/2" Minimum
|
|
|
+ Service Area Service Area
|
|
|
+
|
|
|
+ (Doors can be
|
|
|
+ Removed from
|
|
|
+
|
|
|
+ Hinges)
|
|
|
+ 24 3/4"
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 5 12" X 8" Typ. 11 1/4" 5 1/4" Typ. TOP VIEW 16 3/8" 10 1/8"
|
|
|
+ Duct Flange Overall
|
|
|
+ 10" 5 1/8" Typ. 54 1/2" Overall
|
|
|
+ (Optional Round Typ. EA (with Round Transitions) 15 7/8"
|
|
|
+ 45EVDF (Optional Case
|
|
|
+ 45EVT10 OA
|
|
|
+ Kit Shown) Transition RA
|
|
|
+ Kit Shown) Pressure
|
|
|
+ 4 1/4" Typ. 25 1/4" Ports (4) Typ. 33 7/8" Case 26 1/4"
|
|
|
+ 20 1/4" 36 3/8" Overall
|
|
|
+ FA FRONT VIEW
|
|
|
+ Typ.
|
|
|
+ CL 2 1/4" Control In
|
|
|
+ 7/8" 7/8" Power In CL 14 1/4" Power In 6 3/8" 2 1/8"
|
|
|
+ Typ. Disconnect (2) 7/8" Holes Typ.
|
|
|
+ Switch for Wiring in
|
|
|
+ CL 4 1/8" 7/8" Control In Bottom of E-Box
|
|
|
+ Power In
|
|
|
+ LEFT VIEW
|
|
|
+ CL 2 5/8"
|
|
|
+ Control In
|
|
|
+
|
|
|
+ MoAAvdIaRielaFblL:leOEasVWs4hoC5w0On IiNNn dFimIGenUsiRonAdTraIwOinNg. RIGHT VIEW
|
|
|
+ Drawing Type: Unit Dimension
|
|
|
+ Version: MAY17 UNIT MOUNTING & APPLICATION
|
|
|
+ Can be mounted in any orientation. RA/EA airstream
|
|
|
+ can be switched with OA/FA airstream.
|
|
|
+
|
|
|
+ EV-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+EV 450IN Energy Recovery Ventilator
|
|
|
+ EC Motor Option
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Accessories:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Backdraft damper 10"
|
|
|
+ Typical Airflow Range: 200-530 CFM Wall cap 10" - galvanized, paintable galvanneal
|
|
|
+ Vibration isolation kit
|
|
|
+ AHRI 1060 Certified Core: One L85-G5 Hanging bracket kit
|
|
|
+ Transition kit - 10" round, qty. 2
|
|
|
+ Standard Features: Flange kit - rectangular 12" x 8", 2 flanges
|
|
|
+ Non-fused disconnect Potentiometer speed control - remote installed
|
|
|
+ 24 VAC transformer/relay package Digital time clock - wall mount (TC7D-W),
|
|
|
+ Cross-core differential pressure ports
|
|
|
+ in exterior enclosure (TC7D-E)
|
|
|
+ Filters: Carbon dioxide sensor/control -
|
|
|
+ Total qty. 2, MERV 8: 14" x 20" x 2"
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ Unit Dimensions & Weight: IAQ sensor - wall mount (IAQ-W),
|
|
|
+ 54 1/2" L x 16 3/8" W x 36 3/4" H
|
|
|
+ 140-202 lbs., varies by option(s) duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet):
|
|
|
+ 62" L x 42" W x 22" H ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ 250 lbs. Smoke Detector - duct mount (SD-D)
|
|
|
+ Louver with 10" round duct connection -
|
|
|
+ Motor(s):
|
|
|
+ Qty. 1, 0.5 HP, Direct drive EC blower/ 12" (W) x 12" (H)
|
|
|
+ Electric duct heater - RH series (1-11.5 kW);
|
|
|
+ motor package
|
|
|
+ EK series (1–175 kW);
|
|
|
+ Options: designed for indoor ductwork installation only
|
|
|
+ Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+
|
|
|
+ enhanced, premium
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+
|
|
|
+ both airstreams
|
|
|
+ Double wall construction
|
|
|
+ Exterior paint - white, custom colors
|
|
|
+
|
|
|
+EC MOTOR OPTION OPERATING RANGE Note: Indirect Gas-Fired Duct Furnace is not available on the EV450IN.
|
|
|
+ EV450-IN ECM
|
|
|
+
|
|
|
+ 1.25 487
|
|
|
+ 449
|
|
|
+ EV450IN EC MOTOR
|
|
|
+ Sample Points Depicted in Larger Dots
|
|
|
+
|
|
|
+ Airflow External Static Unit Power 1.00 515
|
|
|
+ (CFM) Pressure Consumption 447
|
|
|
+
|
|
|
+ (Inches Water (Watts) 328
|
|
|
+ Column)
|
|
|
+
|
|
|
+ 229 0.07 75 External Static Pressure (in. w.g.) 521
|
|
|
+ 436
|
|
|
+ 321 Thermal0P.1e6rformance Ratin1g7s1G5 2015.2.xlsx 0.75 EV45031(I5OM)
|
|
|
+
|
|
|
+ 395 0.25 284 520
|
|
|
+
|
|
|
+ 458 0.34 410 198 307 427
|
|
|
+
|
|
|
+ 491 0.40 506 0.50 188
|
|
|
+
|
|
|
+ 299 506
|
|
|
+
|
|
|
+ 209 0.20 80 183 410
|
|
|
+
|
|
|
+ 289 0.43 188 177 284
|
|
|
+ 171 269
|
|
|
+ 350 0.67 315 0.25 80 160 403 500 (Watts)
|
|
|
+ 80
|
|
|
+ 396 0.90 447 76
|
|
|
+
|
|
|
+ 75
|
|
|
+
|
|
|
+ 416 1.00 515 74
|
|
|
+
|
|
|
+Note: Watts is for the entire unit. 0.00
|
|
|
+Note: Airflow performance includes effect of clean, standard filter
|
|
|
+supplied with unit. 200 250 300 350 400 450 500 550 600
|
|
|
+
|
|
|
+ = Actual tested sample points Airflow (cfm)
|
|
|
+
|
|
|
+ CORE PERFORMANCE
|
|
|
+
|
|
|
+ELECTRICAL DATA Airflow (CFM)
|
|
|
+
|
|
|
+ Min. Max. Effectiveness (%) 200 300 400 500 600
|
|
|
+ Cir. Overcurrent
|
|
|
+HP Volts HZ Phase FLA Amps Protection 90%
|
|
|
+
|
|
|
+ Device
|
|
|
+
|
|
|
+0.5 120 60 Single 8.1 10.1 15 70%
|
|
|
+
|
|
|
+0.5 208-230 60 Single 4.8 6.0 15 50%
|
|
|
+
|
|
|
+ 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+6 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ EV450IN Energy Recovery Ventilator SEtCanMdoatrodr oOrpEtiConMotor Option
|
|
|
+
|
|
|
+ 1 1/2" Typ. 47 1/8" Overall ABBREVIATIONS
|
|
|
+ (with Flanges) EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ 44 1/8" Case RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ Door Door INSTALLATION ORIENTATION
|
|
|
+ Swing Swing Unit may be installed in any orientation.
|
|
|
+ NOTE
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 14 1/4" Minimum 44 1/2" Minimum
|
|
|
+ Service Area Service Area
|
|
|
+
|
|
|
+ (Doors can be
|
|
|
+ Removed from
|
|
|
+
|
|
|
+ Hinges)
|
|
|
+ 24 3/4"
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 7 12" X 8" Typ. 11 1/4" 5 1/4" Typ. TOP VIEW 16 3/8" 10 1/8"
|
|
|
+ Duct Flange Overall
|
|
|
+ 10" 5 1/8" Typ. 54 1/2" Overall
|
|
|
+ (Optional Round Typ. EA (with Round Transitions) 15 7/8"
|
|
|
+ 45EVDF (Optional Case
|
|
|
+ 45EVT10 OA
|
|
|
+ Kit Shown) Transition RA
|
|
|
+ Kit Shown) Pressure
|
|
|
+ 4 1/4" Typ. 25 1/4" Ports (4) Typ. 33 7/8" Case 26 1/4"
|
|
|
+ 20 1/4" 36 3/8" Overall
|
|
|
+ FA FRONT VIEW
|
|
|
+ Typ.
|
|
|
+ CL 2 1/4" Control In
|
|
|
+ 7/8" 7/8" Power In CL 14 1/4" Power In 6 3/8" 2 1/8"
|
|
|
+ Typ. Disconnect (2) 7/8" Holes Typ.
|
|
|
+ Switch for Wiring in
|
|
|
+ CL 4 1/8" 7/8" Control In Bottom of E-Box
|
|
|
+ Power In
|
|
|
+ LEFT VIEW
|
|
|
+ CL 2 5/8"
|
|
|
+ Control In
|
|
|
+
|
|
|
+ MoAAvdIaRielaFblL:leOEasVWs4hoC5w0On IiNNn dFimIGenUsiRonAdTraIwOinNg. RIGHT VIEW
|
|
|
+ Drawing Type: Unit Dimension
|
|
|
+ Version: MAY17 UNIT MOUNTING & APPLICATION
|
|
|
+ Can be mounted in any orientation. RA/EA airstream
|
|
|
+ can be switched with OA/FA airstream.
|
|
|
+
|
|
|
+ EV-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+EV 450RT
|
|
|
+ SPECIFICATIONS
|
|
|
+ROOFTOP UNIT
|
|
|
+ Ventilation Type: Accessories:
|
|
|
+Download specification at: Static plate, heat and humidity transfer Filters - MERV 13, 2" (shipped loose)
|
|
|
+renewaire.com/specifications Solid state speed control kit - 115V, qty. 1,
|
|
|
+ Typical Airflow Range: 240-500 CFM
|
|
|
+ 208-230V, qty. 1
|
|
|
+ AHRI 1060 Certified Core: One L85-G5 RA/FA Horizontal plenum box - RTC/RTH configuration
|
|
|
+ RA/FA Vertical and horizontal plenum box
|
|
|
+ Standard Features:
|
|
|
+ Non-fused disconnect - RTR/RTF configuration
|
|
|
+ 24 VAC transformer/relay package Rooftop adapter transition paint - white, custom colors
|
|
|
+ Roof curb - standard 14"
|
|
|
+ Filters: Curb wind clip
|
|
|
+ Total qty. 2, MERV 8: 14" x 20" x 2" Engineered combo curb for Carrier RTU
|
|
|
+ Engineered combo curb for Trane RTU
|
|
|
+ Unit Dimensions & Weight: Digital time clock - wall mount (TC7D-W),
|
|
|
+ 75" L x 36 1/2" W x 19 1/4" H
|
|
|
+ 184-243 lbs., varies by option(s) in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet):
|
|
|
+ 96" L x 47" W x 25" H wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ 350 lbs. IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ Motor(s), choice of: duct mount (IAQ-D)
|
|
|
+ Qty. 1, 0.6 HP (standard single phase) Motion occupancy sensor/control -
|
|
|
+ Qty. 1, 0.5 HP (standard three phase)
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Options: Smoke detector - duct mount (SD-D)
|
|
|
+ Qty. 1, Variable Speed/ECM - Direct Drive Motors Electric duct heater - EK series (1–175 kW);
|
|
|
+
|
|
|
+ (see EV450IN EC Motor submittal) - designed for indoor ductwork installation only
|
|
|
+ 0.5 HP, 120V/1Ph/60HZ,
|
|
|
+ 0.5 HP, 208-230V/1Ph/60HZ
|
|
|
+ Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ enhanced, premium
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+ both airstreams
|
|
|
+ Double wall construction
|
|
|
+ Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ Note: Indirect Gas-Fired Duct Furnace is not available on the EV450RT.
|
|
|
+
|
|
|
+ELECTRICAL DThAeTrmAal Performance Ratings G5 2015.2.xlUsxNIT PERFORMANCEEV450 (IOM)
|
|
|
+
|
|
|
+ Min. Max. Airflow CFM ESP in H20 Watts
|
|
|
+ Phase FLA Cir. Overcurrent
|
|
|
+HP Volts HZ Protection 240 1.00 1P 3P
|
|
|
+ Amps 375 0.75 425 243
|
|
|
+0.6 120 60 Device 450 0.50 493 341
|
|
|
+0.6 208-230 60 Single 7.2 9.0 15 500 0.25 534 412
|
|
|
+0.6 277 60 Single 3.9-3.6 4.9 550 0.00 563 461
|
|
|
+0.5 208-230 60 Single 3.5 4.4 15 593 516
|
|
|
+0.5 460 60 Three 1.7-1.5 2.1
|
|
|
+ Three 0.8 1.0 15 Note: Watts is for the entire unit.
|
|
|
+ Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+ 15
|
|
|
+
|
|
|
+ 15
|
|
|
+
|
|
|
+ CORE PERFORMANCE
|
|
|
+
|
|
|
+ Airflow (CFM)
|
|
|
+
|
|
|
+ Effectiveness (%) 200 300 400 500 600
|
|
|
+
|
|
|
+ 90%
|
|
|
+
|
|
|
+ 70%
|
|
|
+
|
|
|
+ 50%
|
|
|
+
|
|
|
+ 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+8 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ EV450RT Energy Recovery Ventilator Standaarrdd or EC Motor Option
|
|
|
+
|
|
|
+ CURB EV450 11 3/4" 74 3/4" Overall RA Opening ABBREVIATION
|
|
|
+ 48 7/8" Case 11 3/4" X 13" EA: Exhaust Air to outside
|
|
|
+ 45 3/8" O.D. (Triangular) OA: Outside Air intake
|
|
|
+ RA: Room Air to be exhausted
|
|
|
+ 27 1/2" I.D. FA RA 31 1/4" O.D. 31 3/8"FA Opening FA: Fresh Air to inside
|
|
|
+ 13" A A 22 3/4" 5 1/2" X 6 1/4"
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ Unit must be installed in orientation
|
|
|
+ shown.
|
|
|
+
|
|
|
+ NOTE:
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 12 5/8" 16 1/2" 12 5/8" 12 1/4" 3"
|
|
|
+ 41 5/8" I.D.
|
|
|
+ TOP VIEW
|
|
|
+ TOP VIEW
|
|
|
+ 48 3/8" Minimum
|
|
|
+ CURB CROSS-SECTION A-A (TYP.) Service Area
|
|
|
+
|
|
|
+ 1 1/2" X 1/4" 1 7/8" 14" Door
|
|
|
+ Neoprene Gasket 46" Swing
|
|
|
+ 14 1/4" Minimum
|
|
|
+ 3/4" X 3 1/2" Service Area
|
|
|
+ Wooden Nailer (Door can be
|
|
|
+ Removed from
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 9 3" Hinges)
|
|
|
+
|
|
|
+ SECTION A-A 36 1/2" Overall
|
|
|
+ 34 1/4" Case
|
|
|
+
|
|
|
+ 19 1/4" Case 19 1/4" EA OA
|
|
|
+ Overall
|
|
|
+ CL 5 1/4" Power In Disconnect
|
|
|
+ 1 5/8" 30 5/8" CL 4 1/8" Control In FA Switch CL 4 7/8" Control In
|
|
|
+ Typ. Lifting Lugs (2) 7/8" Holes RA CL 4 1/4" Power In
|
|
|
+ for Wiring in
|
|
|
+ Bottom of Unit 44 5/8" Lifting Lugs RIGHT VIEW
|
|
|
+
|
|
|
+ LEFT VIEW FRONT VIEW UNIT MOUNTING & APPLICATION
|
|
|
+ Must be mounted as shown. Airstreams can not be
|
|
|
+ AIRFLOW CONFIGURATION switched. Rooftop adapter accessories can be used
|
|
|
+ to provide RTR and RTF (45RTRF) or RTH and RTC
|
|
|
+ MAovadilaeblle: aEsVsh4ow5n0inRdTimension drawing. (45RTCH) airflow.
|
|
|
+ Drawing Type: Unit Dimension
|
|
|
+ Version: JUL17 EV-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+EV 450RT Energy Recovery Ventilator
|
|
|
+ EC Motor Option
|
|
|
+
|
|
|
+ROOFTOP UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Accessories:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Potentiometer speed control - remote installed
|
|
|
+ Typical Airflow Range: 200-510 CFM RA/FA Horizontal plenum box
|
|
|
+
|
|
|
+ AHRI 1060 Certified Core: One L85-G5 - RTC/RTH configuration
|
|
|
+ RA/FA Vertical and horizontal plenum box
|
|
|
+ Standard Features: - RTR/RTF configuration
|
|
|
+ Non-fused disconnect Rooftop adapter transition paint - white,
|
|
|
+ 24 VAC transformer/relay package
|
|
|
+ custom colors
|
|
|
+ Filters: Roof curb - standard 14"
|
|
|
+ Total qty. 2, MERV 8: 14" x 20" x 2" Curb wind clip
|
|
|
+ Engineered combo curb for Trane RTU
|
|
|
+ Unit Dimensions & Weight: Engineered combo curb for Carrier RTU
|
|
|
+ 75" L x 36 1/2" W x 19 1/4" H Digital time clock - wall mount (TC7D-W),
|
|
|
+ 187-246 lbs., varies by option(s)
|
|
|
+ in exterior enclosure (TC7D-E)
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Carbon dioxide sensor/control -
|
|
|
+ 96" L x 47" W x 25" H
|
|
|
+ 350 lbs. wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+ Motor(s):
|
|
|
+ Qty. 1, 0.5 HP, Direct drive EC blower/ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+ motor package
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Options: Smoke Detector - duct mount (SD-D)
|
|
|
+ Fused disconnect Electric duct heater - EK series (1–175 kW);
|
|
|
+ Integrated programmable controls -
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+ enhanced, premium
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+
|
|
|
+ both airstreams
|
|
|
+ Double wall construction
|
|
|
+ Exterior paint - white, custom colors
|
|
|
+
|
|
|
+EC MOTOR OPTION OPERATING RANGE Note: Indirect Gas-Fired Duct Furnace is not available on the EV450RT.
|
|
|
+
|
|
|
+ EV450-RT ECM
|
|
|
+
|
|
|
+ 1.25 470
|
|
|
+ 436
|
|
|
+ EV450RT EC MOTOR
|
|
|
+ Sample Points Depicted in Larger Dots
|
|
|
+
|
|
|
+ Airflow External Static Unit Power 1.00 502
|
|
|
+ (CFM) Pressure Consumption 451
|
|
|
+ 337
|
|
|
+ (Inches Water (Watts)
|
|
|
+ Column)
|
|
|
+
|
|
|
+ 217 0.07 78 External Static Pressure (in. w.g.) 516
|
|
|
+ 447
|
|
|
+ 305 Thermal0P.1e6rformance Ratin1g8s0G5 2015.2.xlsx 0.75 324
|
|
|
+
|
|
|
+ EV450 (IOM)
|
|
|
+
|
|
|
+ 375 0.25 301 204 521
|
|
|
+
|
|
|
+ 435 0.34 426 317 438
|
|
|
+
|
|
|
+ 467 0.40 520 0.50 196
|
|
|
+ 310
|
|
|
+ 200 0.20 85 426 520
|
|
|
+ 191
|
|
|
+
|
|
|
+ 274 0.43 196 0.25 85 186 301
|
|
|
+ 82 180 289
|
|
|
+ 332 0.67 324 80 174 415 514 (Watts)
|
|
|
+
|
|
|
+ 376 0.90 451 78
|
|
|
+ 77
|
|
|
+ 395 1.00 502
|
|
|
+
|
|
|
+ 0.00
|
|
|
+
|
|
|
+Note: Watts is for the entire unit. 200 250 300 350 400 450 500 550 600
|
|
|
+Note: Airflow performance includes effect of clean, standard filter
|
|
|
+supplied with unit. Airflow (cfm)
|
|
|
+ = Actual tested sample points
|
|
|
+ELECTRICAL DATA
|
|
|
+ CORE PERFORMANCE
|
|
|
+
|
|
|
+ Min. Max. Airflow (CFM)
|
|
|
+ Cir. Overcurrent
|
|
|
+HP Volts HZ Phase FLA Amps Protection 200 300 400 500 600
|
|
|
+
|
|
|
+ Device Effectiveness (%) 90%
|
|
|
+
|
|
|
+0.5 120 60 Single 8.1 10.1 15
|
|
|
+
|
|
|
+0.5 208-230 60 Single 4.8 6.0 15 70%
|
|
|
+
|
|
|
+ 50%
|
|
|
+
|
|
|
+ 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+10 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ EV450RT Energy Recovery Ventilator EStCanMdoatrodr oOrpEtiConMotor Option
|
|
|
+
|
|
|
+ CURB EV450 11 3/4" 74 3/4" Overall RA Opening ABBREVIATION
|
|
|
+ 48 7/8" Case 11 3/4" X 13" EA: Exhaust Air to outside
|
|
|
+ 45 3/8" O.D. (Triangular) OA: Outside Air intake
|
|
|
+ RA: Room Air to be exhausted
|
|
|
+ 27 1/2" I.D. FA RA 31 1/4" O.D. 31 3/8"FA Opening FA: Fresh Air to inside
|
|
|
+ 13" A A 22 3/4" 5 1/2" X 6 1/4"
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ Unit must be installed in orientation
|
|
|
+ shown.
|
|
|
+
|
|
|
+ NOTE:
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 12 5/8" 16 1/2" 12 5/8" 12 1/4" 3"
|
|
|
+ 41 5/8" I.D.
|
|
|
+ TOP VIEW
|
|
|
+ TOP VIEW
|
|
|
+ 48 3/8" Minimum
|
|
|
+ CURB CROSS-SECTION A-A (TYP.) Service Area
|
|
|
+
|
|
|
+ 1 1/2" X 1/4" 1 7/8" 14" Door
|
|
|
+ Neoprene Gasket 46" Swing
|
|
|
+ 14 1/4" Minimum
|
|
|
+ 3/4" X 3 1/2" Service Area
|
|
|
+ Wooden Nailer (Door can be
|
|
|
+ Removed from
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 11 3" Hinges)
|
|
|
+
|
|
|
+ SECTION A-A 36 1/2" Overall
|
|
|
+ 34 1/4" Case
|
|
|
+
|
|
|
+ 19 1/4" Case 19 1/4" EA OA
|
|
|
+ Overall
|
|
|
+ CL 5 1/4" Power In Disconnect
|
|
|
+ 1 5/8" 30 5/8" CL 4 1/8" Control In FA Switch CL 4 7/8" Control In
|
|
|
+ Typ. Lifting Lugs (2) 7/8" Holes RA CL 4 1/4" Power In
|
|
|
+ for Wiring in
|
|
|
+ Bottom of Unit 44 5/8" Lifting Lugs RIGHT VIEW
|
|
|
+
|
|
|
+ LEFT VIEW FRONT VIEW UNIT MOUNTING & APPLICATION
|
|
|
+ Must be mounted as shown. Airstreams can not be
|
|
|
+ AIRFLOW CONFIGURATION switched. Rooftop adapter accessories can be used
|
|
|
+ to provide RTR and RTF (45RTRF) or RTH and RTC
|
|
|
+ MAovadilaeblle: aEsVsh4ow5n0inRdTimension drawing. (45RTCH) airflow.
|
|
|
+ Drawing Type: Unit Dimension
|
|
|
+ Version: JUL17 EV-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+EV 450RT Energy Recovery Ventilator
|
|
|
+ Standard or EC Motor Option
|
|
|
+
|
|
|
+DUCTING ACCESSORIES RTV
|
|
|
+
|
|
|
+Rooftop Curb (45Curb) EV450RT ID = 13" X 45 3/8"
|
|
|
+Standard roof curb shown (available option). CURB EV450 13" TYP
|
|
|
+ 74 3/4" Overall
|
|
|
+ EA 45O3/A8" O.D. 11 3/4"
|
|
|
+ 48 7/8" Case
|
|
|
+
|
|
|
+ FA R
|
|
|
+
|
|
|
+ 27 1/2" I.D. RA
|
|
|
+ 13"
|
|
|
+
|
|
|
+ 31 1/4" O.D.
|
|
|
+ 22 3/4"
|
|
|
+ 11" FA 1 7/8" TYP
|
|
|
+
|
|
|
+ FA RA
|
|
|
+
|
|
|
+ A ROOF CURB A
|
|
|
+
|
|
|
+ EV450RT WITH STANDARD ROOF
|
|
|
+
|
|
|
+ CURB (45CURB12)5/8" 16 1/2" 12 5/8" 12 1/4" TOP V3"I
|
|
|
+ 41 5/8" I.D.
|
|
|
+ STANABDBTRAEOVRIPADTVIORINEOWOF C
|
|
|
+ TOP74V3I/E4"WOverall
|
|
|
+ CURB EV450 RA Opening EA: Exhaust Air to outsid
|
|
|
+ 48 7/8" Case OA: Outside Air intake
|
|
|
+ 45 3/8" O.D.
|
|
|
+ 11 3/4" 11 3/4" X 13" RA:4R8o3o/m8" AMirintiombuemexh
|
|
|
+ (Triangular) FA: FrSeeshrvAicier tAorienaside
|
|
|
+
|
|
|
+ CURB CROSS-SECTION A-A (TYP.) INSTALLATION ORIENTAT
|
|
|
+ Unit must be installed in
|
|
|
+ 27 1/2" I.D. FA RA 31 1/4" O.D. 1 1/2" X 1/4" 1 7/8" 14" shown.
|
|
|
+ 13" A A 22 3/4" 46"
|
|
|
+ Neoprene Gasket 14 1/4"31Mi3n/i8"mum NOTE:
|
|
|
+ Service Area
|
|
|
+ UNLESS OTHERWISE SPECIFIED, DIMENSIONS (Door can be 1. UNLESS OTHERWISE SP
|
|
|
+ Removed from
|
|
|
+ 3/4" X 3 1/2" AND TOLERANCES ARE IN INCHES. Hinges) DIMENSIONS ARE ROUN
|
|
|
+ LINEAR ± .015 RenewAire NEAREDSoToErIGHTH OF AN
|
|
|
+
|
|
|
+ Wooden Nailer HOLE SIZE ± .005
|
|
|
+ < ± 3 DEG
|
|
|
+ TITLE:
|
|
|
+ 63 2. SPECSwIFiInCgATIONS MAY
|
|
|
+ SURFACE FINISH 450RT ADAPTER CURB TDOIMCHEANNSGIOE NWSITHOUT N
|
|
|
+
|
|
|
+ 3" DO NOT SCALE DRAWING. REMOVE DRAWN BY: DATE: D
|
|
|
+
|
|
|
+ MATERIAL:
|
|
|
+
|
|
|
+ 12 5/8" 16 1/2" 12 5/8" 12 1/4" SECTSEIOE BNILAL O-AF MATERIALS ALLFBAURROS. BpREeAKnSiHnAgRP EDGES. KWE 4-16-02 4
|
|
|
+ 5 1/2" X 6 1/4" APPLICABLE STANDARDS: DIM. AND
|
|
|
+ LEVEL DESCRIPTION DATE BY FINISH: 3" CHECKED BY: DATE: S
|
|
|
+ TOL. ANSI Y14.5
|
|
|
+ 41 5/8" I.D. - -
|
|
|
+ MAY16 REFORMAT 5/20/16 KMC _TOP VIEW
|
|
|
+
|
|
|
+ TOP VIEW 14"
|
|
|
+ 46"
|
|
|
+ 14 1/4" Minimum 48 3/8" Minimum 19 1/4"
|
|
|
+ Service Area Service Area Overall
|
|
|
+ (Door can be 19 1/4" Case
|
|
|
+ RTR/RTCFURB CROSS-SECTION A-A (TYP.) Removed from EA
|
|
|
+ Hinges)
|
|
|
+ 1 1/2" X 1/4" 1 7/8"
|
|
|
+
|
|
|
+Rooftop Adapter for RNeTopRrenae nGadskeRt TF Orientations stack1tT5hy/ep8".optional 30 5/8" on the CL 5 1/4" Power In FA
|
|
|
+For horizontal connection of eithe3r/4t"hXe3F1r/e2s" h Air duct or the Return Air duct, RA
|
|
|
+ RLTifFtin/RgTLuRgAs dapter stanCdLa4rd1/r8o" oCfocnutrrobl .In
|
|
|
+ 44 5/8" Lifting Lugs
|
|
|
+ Wooden Nailer Door (2) 7/8" Holes
|
|
|
+ Swing for Wiring in FRONT VIEW
|
|
|
+Duct openings to be field cut into adapter. Opening location and size is flexible.
|
|
|
+ 36 1/2" Overall
|
|
|
+ 3" Bottom of Unit
|
|
|
+
|
|
|
+ SECTION A-A LEFT VIEW EV450RT
|
|
|
+
|
|
|
+ Model: EV450RT 34 1/4" Case
|
|
|
+
|
|
|
+ 19 1/4" Case OA Drawing Type: Unit Dimension OA
|
|
|
+
|
|
|
+EA 19 1/4" VEeArsion: JUL17
|
|
|
+ Overall
|
|
|
+ EA OA
|
|
|
+
|
|
|
+ FA FA RA 14"
|
|
|
+
|
|
|
+28" 1 5/8" RA CL 5 1/4" Power In28" FA Disconnect CL 4 7/8" Con
|
|
|
+ Typ. 30 5/8" ADAPTECRL 4(F1/U8L" CLYontrol In CL 4 1/4" Powe
|
|
|
+ Lifting Lugs RA Switch
|
|
|
+ RIGHT VIEW
|
|
|
+ INS(U2)LA7T/E8D" H)oles
|
|
|
+
|
|
|
+ for Wiring in 44 5/8" Lifting Lugs
|
|
|
+
|
|
|
+ E(V4455R0TRRTF)WAITNHDRLCTEFUF/TRRBVTRI(E4AW5DCAUPRTBE)R Bottom of Unit EV450RTFRWOITNHTRVTFIE/WRTR ADAPTER ROOF CURB
|
|
|
+ (45RTRF) AND CURB (45CURB)
|
|
|
+
|
|
|
+ ModINeRl: TERVC45O0NRTFIGURATION IN RTF CONFIGURATION
|
|
|
+
|
|
|
+ Drawing Type: Unit Dimension
|
|
|
+
|
|
|
+ Version: JUL17
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice. UNLESS OTHERWISE SPECIFIED, DIMENSIONS RenewAire 4510 Helgesen Dr.
|
|
|
+12 RENEWAIRE.COM 1.800.627.4499 AND TOLERANCES ARE IN INCHES. Madison, WI 53718 USA
|
|
|
+ TITLE:
|
|
|
+ LINEAR ± .015 TEL: (608) 221-4499
|
|
|
+ HOLE SIZE ± .005 450RT ADAPTER CURB DIMENSIONS FAX: (608) 221-2824
|
|
|
+ TOLL FREE: (800) 627-4499
|
|
|
+ < ± 3 DEG DO NOT SCALE DRAWING. REMOVE DRAWN BY: DATE:
|
|
|
+ DRAWING NO. REVISION
|
|
|
+ 63
|
|
|
+ SURFACE FINISH
|
|
|
+
|
|
|
+ MATERIAL:
|
|
|
+ EV 450RT Energy Recovery Ventilator
|
|
|
+ Standard or EC Motor Option
|
|
|
+
|
|
|
+ DUCTING ACCESSORIES
|
|
|
+
|
|
|
+ RTC/RTH
|
|
|
+
|
|
|
+ Rooftop Adapter for RTC and RTH Orientations
|
|
|
+ The RTH/RTC Adapter allows horizontal connection of both the Fresh Air and the Return Air ducts. It is also possible to connect the adapter directly to the
|
|
|
+ return plenum of most rooftop units (openings must be cut into RTU). Duct openings to be field cut into adapter. Opening location and size is flexible.
|
|
|
+ 31 3/8"
|
|
|
+ ABBREVIATION
|
|
|
+ EV-SERIES
|
|
|
+ RA Opening EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+
|
|
|
+RA 11 3/4" X 13" RA: Room Air to be exhausted
|
|
|
+
|
|
|
+ (Triangular) FA: Fresh Air to inside
|
|
|
+
|
|
|
+ 31 1/4" UINnSitTAmLuLAstTbIOeENiAnOstRaIlEleNdTAinTIoOriNentation OA
|
|
|
+
|
|
|
+ shown. OA
|
|
|
+
|
|
|
+ ADAPTE1NR.OUTN(EFL: EUSSLOLYTHERWISE SPECIFIED, FA RA 15 1/2" 38"
|
|
|
+ INSDNUEIMALERANESSTTIOEENIDGSH)ATRHEORFOAUNNDINECDHT.O THE
|
|
|
+
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT RA
|
|
|
+ TO CHANGE WITHOUT NOTICE. FA
|
|
|
+
|
|
|
+IEW FA Opening
|
|
|
+
|
|
|
+ 5 1/2" X 6 1/4" 17 1/2" 46"
|
|
|
+CURB (14" HIGH) EV450RT WITH ADAPTER (45RTCH)
|
|
|
+
|
|
|
+de
|
|
|
+
|
|
|
+hausted
|
|
|
+
|
|
|
+TION ABBREVIATIONS
|
|
|
+n orientation EA: Exhaust Air to outdoors
|
|
|
+
|
|
|
+OA: Outdoor Air intake PECIFIED, 4510 Helgesen Dr. UNLESS OTHERWISE SPECIFIED, DIMENSIONS RenewAire 4510 Helgesen Dr.
|
|
|
+ Madison, WI 53718 USA AND TOLERANCES ARE IN INCHES. Madison, WI 53718 USA
|
|
|
+
|
|
|
+RA: Room Air to be exhausted NDED TO THETEL: (608) 221-4499 LINEAR ± .015 TEL: (608) 221-4499
|
|
|
+ HOLE SIZE ± .005 FAX: (608) 221-2824
|
|
|
+N INCH. FAX: (608) 221-2824 TOLL FREE: (800) 627-4499
|
|
|
+ TOLL FREE: (800) 627-4499 < ± 3 DEG
|
|
|
+
|
|
|
+Y BE SUBJECT FA: Fresh Air to inside 63 TITLE:
|
|
|
+ SURFACE FINISH
|
|
|
+NOTICE. 450RT ADAPTER CURB DIMENSIONS
|
|
|
+ MATERIAL:
|
|
|
+DRAWING NO. REVISION DO NOT SCALE DRAWING. REMOVE DRAWN BY: DATE: DRAWING NO. REVISION
|
|
|
+ SEE BILL OF MATERIALS ALL BURRS. BREAK SHARP EDGES.
|
|
|
+450RT_adaptcurb_DIMS_MLEAVEYL16 DESCRIPTION 36 1/2" Overall KWE 4-16-02 450RT_adaptcurb_DIMS_JUN16
|
|
|
+ FINISH: APPLICABLE STANDARDS: DIM. AND
|
|
|
+ DATE BY TOL. ANSI Y14.5 CHECKED BY: DATE: SCALE: SIZE: SHEET:
|
|
|
+ 6/21/16 _ 3 OF 3
|
|
|
+SCALE: SIZE: SHJEUETN: 16 REFORMAT KMC - - 1/42 A
|
|
|
+
|
|
|
+ 1/42 A 1 OF 3 34 1/4" Case
|
|
|
+
|
|
|
+ OA CL 4 7/8" Control In
|
|
|
+ CL 4 1/4" Power In
|
|
|
+ Disconnect
|
|
|
+ Switch RIGHT VIEW
|
|
|
+
|
|
|
+ ntrol In
|
|
|
+ er In
|
|
|
+
|
|
|
+W
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 13
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1XINH Energy Recovery Ventilator
|
|
|
+ Standarrdd & Bypass Economizer Option
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS Options:
|
|
|
+ Qty. 2, Variable Speed/ECM - Direct Drive Motors
|
|
|
+Download specification at: Ventilation Type:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer (see HE1XINH EC Motor submittal) -
|
|
|
+ 0.5 HP, 120V/1Ph/60HZ,
|
|
|
+ Typical Airflow Range: 250-925 CFM 0.5 HP, 208-230V/1Ph/60HZ
|
|
|
+ Independent blower control
|
|
|
+ AHRI 1060 Certified Core: One L125-G5 Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ Standard Features: enhanced, premium
|
|
|
+ Non-fused disconnect Bypass economizer damper
|
|
|
+ 24 VAC transformer/relay package (see bypass DIM drawing) -
|
|
|
+ Cross-core differential pressure ports dry-bulb temperature controls (standard),
|
|
|
+ enthalpy controls (option)
|
|
|
+ Filters: Low-leakage motorized isolation dampers -
|
|
|
+ Total qty. 2, MERV 8: 20" x 20" x 2" OA, RA or both airstreams
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+ Unit Dimensions & Weight: both airstreams
|
|
|
+ 54 3/4" L x 23 3/4" W x 35 3/4" H Double wall construction
|
|
|
+ 204-275 lbs., varies by option(s) Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Accessories:
|
|
|
+ 63" L x 30" W x 56" H Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 325 lbs. Backdraft damper 12"
|
|
|
+ Accessories box shipped loose on top of unit. Motorized isolation damper - both airstreams
|
|
|
+ Wall cap 12" - galvanized, paintable galvanneal
|
|
|
+ Motor(s): Solid state speed control kit - 115V,
|
|
|
+ Qty. 2, 0.75 HP ea., Direct drive blower/standard
|
|
|
+ 208-230V (1 required per motor)
|
|
|
+ motor packages Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ Thermal Performance Ratings G5 2015.2.xlsx HE1X (IOM) in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - RH series (1-11.5 kW);
|
|
|
+
|
|
|
+ EK series (1–175 kW);
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+ Motor HP External Static Pressure (Inches Water Column)
|
|
|
+
|
|
|
+ Phase 0.0 0.25 0.5 0.75 0.9 1.25 1.5
|
|
|
+
|
|
|
+ 0.75 970 CFM 925 CFM 860 CFM 795 CFM 750 CFM 635 CFM 480 CFM
|
|
|
+Single Phase 1,490 Watts 1,375 Watts 1,270 Watts 1,160 Watts 1,090 Watts 950 Watts 825 Watts
|
|
|
+
|
|
|
+ 0.75 970 CFM 925 CFM 860 CFM 795 CFM 750 CFM 635 CFM 480 CFM
|
|
|
+Three Phase 1,246 Watts 1,158 Watts 1,039 Watts 928 Watts 856 Watts 691 Watts 509 Watts
|
|
|
+
|
|
|
+Note: Watts is for the entire unit (two motors).
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+HP Volts HZ Phase FLA Min. Max. Airflow (CFM)
|
|
|
+ per Cir. Overcurrent
|
|
|
+ motor Amps Protection Effectiveness (%) 200 400 600 800 1000
|
|
|
+ 90%
|
|
|
+ Device
|
|
|
+
|
|
|
+0.75 120 60 Single 9.0 20.3 25
|
|
|
+
|
|
|
+0.75 208-230 60 Single 4.5 10.1 15 70%
|
|
|
+
|
|
|
+0.75 277 60 Single 3.9 8.8 15 50%
|
|
|
+
|
|
|
+0.75 208-230 60 Three 1.7-2.3 5.2 15
|
|
|
+
|
|
|
+0.75 460 60 Three 1.15 2.6 15 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+14 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1XINH Energy Recovery Ventilator Standaarrdd or EC Motor Option
|
|
|
+
|
|
|
+ 21 3/4" Case 29" ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to Outside
|
|
|
+ Door OA: Outside Air Intake
|
|
|
+ Swing RA: Room Air to be Exhausted
|
|
|
+ 54 3/4" Overall FA: Fresh Air to Inside
|
|
|
+ 49" MinimumDoor 12" ISOMETRIC VIEW INSTALLATION ORIENTATION
|
|
|
+ Service AreaSwing Unit may be installed in any
|
|
|
+ (Doors can be orientation.
|
|
|
+ Removed from Hinges.) TYP. 9" NOTE
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ TYP. DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3.DAMPERS SHIPPED LOOSE, FIELD
|
|
|
+ INSTALLATION REQUIRED.
|
|
|
+
|
|
|
+ Alternate 6"
|
|
|
+ Power Wiring
|
|
|
+ Alternate Inlet 7/8" TYP.
|
|
|
+ Control Wiring
|
|
|
+ Inlet 7/8" 20 1/8" Minimum FRONT VIEW RIGHT VIEW
|
|
|
+ Service Area
|
|
|
+ TOP VIEW (Doors can be (OA/RA) DAMPER OPTION (QTY.2)
|
|
|
+ (SHIPPED LOOSE)
|
|
|
+ Removed from Hinges.)
|
|
|
+
|
|
|
+ SCALE 1:16
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 15 23 3/4" Door-interlocked 2 7/8" Typ. 12"
|
|
|
+ Overall OA Isolation Typ.
|
|
|
+ Disconnect Switch Pressure Damper
|
|
|
+ 12 7/8" Control Wiring 49 1/8" Ports (4) Typ. Wiring Conn. 10 3/8"
|
|
|
+ Inlet 7/8" Case
|
|
|
+
|
|
|
+ EA OA 27 1/2"
|
|
|
+ 35 5/8" Overall
|
|
|
+ 27 5/8" Power Wiring 34 7/8" Case RA Isolation
|
|
|
+ 8 7/8" Typ. Inlet 7/8" Damper
|
|
|
+ RA Wiring Conn.
|
|
|
+ FA
|
|
|
+
|
|
|
+ 12"
|
|
|
+ Typ.
|
|
|
+
|
|
|
+ 8 5/8" Leveling 3/4"-1 7/8" Typ. 10 3/8"
|
|
|
+ Feet (4)
|
|
|
+ LEFT VIEW RIGHT VIEW
|
|
|
+ FRONT VIEW
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+ MAoIRdFeLlO: W HEC1OXNINFIHGURATION Can be mounted in any orientation. RA/EA airstream
|
|
|
+ DAravaiwlabilenags shToywpn ined:imUennsioitn dDraiwminge. nsion can be switched with OA/FA airstream unless
|
|
|
+ Version: MAY18 certain options are selected.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1XINH Energy Recovery Ventilator
|
|
|
+ EC Motor Option
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications
|
|
|
+ Static plate, heat and humidity transfer Fused disconnect
|
|
|
+EC MOTOR OPTION OPERATING RANGE
|
|
|
+ HE1XINH EC MOTOR Typical Airflow Range: 250-1,100 CFM Integrated programmable controls -
|
|
|
+ AHRI 1060 Certified Core: One L125-G5 enhanced, premium
|
|
|
+
|
|
|
+ Bypass economizer damper
|
|
|
+
|
|
|
+ Standard Features: (see bypass DIM drawing) -
|
|
|
+ Non-fused disconnect dry-bulb temperature controls (standard),
|
|
|
+
|
|
|
+ 24 VAC transformer/relay package enthalpy controls (option)
|
|
|
+
|
|
|
+ Cross-core differential pressure ports Low-leakage motorized isolation dampers -
|
|
|
+
|
|
|
+ Filters: OA, RA or both airstreams
|
|
|
+ Total qty. 2, MERV 8: 20" x 20" x 2" Qty. 2, Factory mounted filter alarms -
|
|
|
+
|
|
|
+ both airstreams
|
|
|
+
|
|
|
+ Unit Dimensions & Weight: Double wall construction
|
|
|
+
|
|
|
+ 54 3/4" L x 23 3/4" W x 35 3/4" H Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ 207-278 lbs., varies by option(s) Accessories:
|
|
|
+
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Filters - MERV 13, 2" (shipped loose)
|
|
|
+
|
|
|
+ 63" L x 30" W x 56" H Backdraft damper 12"
|
|
|
+
|
|
|
+ 325 lbs. Motorized isolation damper - both airstreams
|
|
|
+
|
|
|
+ Accessories box shipped loose on top of unit. Wall cap 12" - galvanized, paintable galvanneal
|
|
|
+
|
|
|
+ Motor(s): Potentiometer speed control - remote installed
|
|
|
+ Qty. 2, 0.5 HP ea., Direct drive EC blower/ Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ motor packages in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+
|
|
|
+ Electric duct heater - RH series (1-11.5 kW);
|
|
|
+
|
|
|
+ EK series (1–175 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+
|
|
|
+ HE1X-IN ECM (HIondriVre)ct gas-fired duct furnace - GH series
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ 1.75
|
|
|
+
|
|
|
+ Sample Points Depicted in Larger Dots
|
|
|
+
|
|
|
+ External Static 1.50 992
|
|
|
+ Pressure 918
|
|
|
+ Airflow Unit Power
|
|
|
+ (CFM) (Inches Water Consumption
|
|
|
+ Column)
|
|
|
+ (Watts) 1.25
|
|
|
+
|
|
|
+ 324 0.04 86 External Static Pressure (in. w.g.) 655 1029
|
|
|
+ 911
|
|
|
+ 446 Thermal0P.0e7rformance Ratin1g5s0G5 2015.2.xlsx 1.00 HE1X (IOM)
|
|
|
+ 1075
|
|
|
+ 647 0.15 300 643 871
|
|
|
+
|
|
|
+ 794 0.24 564 0.75 1068
|
|
|
+
|
|
|
+ 392 599 852
|
|
|
+
|
|
|
+ 929 0.33 827
|
|
|
+
|
|
|
+ 1019 0.41 1042 386 583 1056
|
|
|
+ 359 572 839
|
|
|
+ 340
|
|
|
+ 300 0.11 91 0.50 1042
|
|
|
+ 173
|
|
|
+ 827
|
|
|
+
|
|
|
+ 406 0.20 160 564
|
|
|
+ 560
|
|
|
+ 579 0.42 359 0.25 164 322 818 1029 (Watts)
|
|
|
+ 97 160 300
|
|
|
+ 156 273
|
|
|
+ 713 0.65 599 89 153
|
|
|
+ 85 150 750
|
|
|
+ 828 0.89 871 0.00 148 Airflow (cfm)
|
|
|
+ 250 1000 1250
|
|
|
+ 500
|
|
|
+
|
|
|
+ 883 1.00 1075 = Actual tested sample points
|
|
|
+
|
|
|
+Note: Watts is for the entire unit. CORE PERFORMANCE
|
|
|
+Note: Airflow performance includes effect of clean, standard filter
|
|
|
+supplied with unit. Airflow (CFM)
|
|
|
+
|
|
|
+ELECTRICAL DATA Effectiveness (%) 200 400 600 800 1000
|
|
|
+
|
|
|
+ 90%
|
|
|
+
|
|
|
+HP Volts HZ Phase FLA Min. Max. 70%
|
|
|
+ per Cir. Overcurrent
|
|
|
+ motor Amps Protection
|
|
|
+
|
|
|
+ Device
|
|
|
+
|
|
|
+0.5 120 60 Single 8.1 18.2 25 50%
|
|
|
+
|
|
|
+0.5 208-230 60 Single 4.8 10.8 15 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+16 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1XINH Energy Recovery Ventilator EStCanMdoatrodr oOrpEtiConMotor Option
|
|
|
+
|
|
|
+ 21 3/4" Case 29" ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to Outside
|
|
|
+ Door OA: Outside Air Intake
|
|
|
+ Swing RA: Room Air to be Exhausted
|
|
|
+ 54 3/4" Overall FA: Fresh Air to Inside
|
|
|
+ 49" MinimumDoor 12" ISOMETRIC VIEW INSTALLATION ORIENTATION
|
|
|
+ Service AreaSwing Unit may be installed in any
|
|
|
+ (Doors can be orientation.
|
|
|
+ Removed from Hinges.) TYP. 9" NOTE
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ TYP. DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3.DAMPERS SHIPPED LOOSE, FIELD
|
|
|
+ INSTALLATION REQUIRED.
|
|
|
+
|
|
|
+ Alternate 6"
|
|
|
+ Power Wiring
|
|
|
+ Alternate Inlet 7/8" TYP.
|
|
|
+ Control Wiring
|
|
|
+ Inlet 7/8" 20 1/8" Minimum FRONT VIEW RIGHT VIEW
|
|
|
+ Service Area
|
|
|
+ TOP VIEW (Doors can be (OA/RA) DAMPER OPTION (QTY.2)
|
|
|
+ (SHIPPED LOOSE)
|
|
|
+ Removed from Hinges.)
|
|
|
+
|
|
|
+ SCALE 1:16
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 17 23 3/4" Door-interlocked 2 7/8" Typ. 12"
|
|
|
+ Overall OA Isolation Typ.
|
|
|
+ Disconnect Switch Pressure Damper
|
|
|
+ 12 7/8" Control Wiring 49 1/8" Ports (4) Typ. Wiring Conn. 10 3/8"
|
|
|
+ Inlet 7/8" Case
|
|
|
+
|
|
|
+ EA OA 27 1/2"
|
|
|
+ 35 5/8" Overall
|
|
|
+ 27 5/8" Power Wiring 34 7/8" Case RA Isolation
|
|
|
+ 8 7/8" Typ. Inlet 7/8" Damper
|
|
|
+ RA Wiring Conn.
|
|
|
+ FA
|
|
|
+
|
|
|
+ 12"
|
|
|
+ Typ.
|
|
|
+
|
|
|
+ 8 5/8" Leveling 3/4"-1 7/8" Typ. 10 3/8"
|
|
|
+ Feet (4)
|
|
|
+ LEFT VIEW RIGHT VIEW
|
|
|
+ FRONT VIEW
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+ MAoIRdFeLlO: W HEC1OXNINFIHGURATION Can be mounted in any orientation. RA/EA airstream
|
|
|
+ DAravaiwlabilenags shToywpn ined:imUennsioitn dDraiwminge. nsion can be switched with OA/FA airstream unless
|
|
|
+ Version: MAY18 certain options are selected.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1XINH Energy Recovery Ventilator
|
|
|
+ Standard with Bypass Economizer
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS Options:
|
|
|
+ Qty. 2, Variable Speed/ECM - Direct Drive Motors
|
|
|
+Download specification at: Ventilation Type:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer (see HE1XINH EC Motor submittal) -
|
|
|
+ 0.5 HP, 120V/1Ph/60HZ,
|
|
|
+ Typical Airflow Range: 250-925 CFM 0.5 HP, 208-230V/1Ph/60HZ
|
|
|
+ Independent blower control
|
|
|
+ AHRI 1060 Certified Core: One L125-G5 Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ Standard Features: enhanced, premium
|
|
|
+ Non-fused disconnect Bypass economizer damper
|
|
|
+ 24 VAC transformer/relay package (see bypass DIM drawing) -
|
|
|
+ Cross-core differential pressure ports dry-bulb temperature controls (standard),
|
|
|
+ enthalpy controls (option)
|
|
|
+ Filters: Low-leakage motorized isolation dampers -
|
|
|
+ Total qty. 2, MERV 8: 20" x 20" x 2" OA, RA or both airstreams
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+ Unit Dimensions & Weight: both airstreams
|
|
|
+ 54 3/4" L x 23 3/4" W x 35 3/4" H Double wall construction
|
|
|
+ 204-275 lbs., varies by option(s) Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Accessories:
|
|
|
+ 63" L x 30" W x 56" H Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 325 lbs. Backdraft damper 12"
|
|
|
+ Accessories box shipped loose on top of unit. Motorized isolation damper - both airstreams
|
|
|
+ Wall cap 12" - galvanized, paintable galvanneal
|
|
|
+ Motor(s): Solid state speed control kit - 115V,
|
|
|
+ Qty. 2, 0.75 HP ea., Direct drive blower/standard
|
|
|
+ 208-230V (1 required per motor)
|
|
|
+ motor packages Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ Thermal Performance Ratings G5 2015.2.xlsx HE1X (IOM) in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - RH series (1-11.5 kW);
|
|
|
+
|
|
|
+ EK series (1–175 kW);
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+ Motor HP External Static Pressure (Inches Water Column)
|
|
|
+
|
|
|
+ Phase 0.0 0.25 0.5 0.75 0.9 1.25 1.5
|
|
|
+
|
|
|
+ 0.75 970 CFM 925 CFM 860 CFM 795 CFM 750 CFM 635 CFM 480 CFM
|
|
|
+Single Phase 1,490 Watts 1,375 Watts 1,270 Watts 1,160 Watts 1,090 Watts 950 Watts 825 Watts
|
|
|
+
|
|
|
+ 0.75 970 CFM 925 CFM 860 CFM 795 CFM 750 CFM 635 CFM 480 CFM
|
|
|
+Three Phase 1,246 Watts 1,158 Watts 1,039 Watts 928 Watts 856 Watts 691 Watts 509 Watts
|
|
|
+
|
|
|
+Note: Watts is for the entire unit (two motors).
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+HP Volts HZ Phase FLA Min. Max. Airflow (CFM)
|
|
|
+ per Cir. Overcurrent
|
|
|
+ motor Amps Protection Effectiveness (%) 200 400 600 800 1000
|
|
|
+ 90%
|
|
|
+ Device
|
|
|
+
|
|
|
+0.75 120 60 Single 9.0 20.3 25
|
|
|
+
|
|
|
+0.75 208-230 60 Single 4.5 10.1 15 70%
|
|
|
+
|
|
|
+0.75 277 60 Single 3.9 8.8 15 50%
|
|
|
+
|
|
|
+0.75 208-230 60 Three 1.7-2.3 5.2 15
|
|
|
+
|
|
|
+0.75 460 60 Three 1.15 2.6 15 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+18 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1XINH Energy Recovery Ventilator SWtaitnhdBayrdpawsisthEBcyopnaosms iEzecronOopmtiiozner(Standard & EC Motor)
|
|
|
+
|
|
|
+ 21 3/4" Case 29" Bypass 12" Round Bypass Duct Connection ABBREVIATIONS
|
|
|
+ Damper (Direct Mount to Damper, By Others) EA: Exhaust Air to Outside
|
|
|
+ Conn. Location Door OA: Outside Air Intake
|
|
|
+ 12" Bypass Swing BP RA: Room Air to be Exhausted
|
|
|
+ Damper FA: Fresh Air to Inside
|
|
|
+ 49" Minimum Service Area EA OA BP: Bypass Air Intake
|
|
|
+ (Not Shown) (Doors can be Removed INSTALLATION ORIENTATION
|
|
|
+ 54 3/4" Overall FA RA Unit may be installed in any
|
|
|
+ 7 5/8" from Hinges.) orientation.
|
|
|
+ Face Damper NOTE
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ BYPASS AIRFLOW SCHEMATIC DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ FRONT VIEW 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ Door 3. UNITS WITH BYPASS WILL REQUIRE
|
|
|
+ Swing ADDITIONAL SPACE FOR THE
|
|
|
+ CONNECTION OF THE BYPASS DUCT
|
|
|
+ 12" 9" (BY OTHERS).
|
|
|
+ 4. FOR INSTALLATION DETAILS, REFER
|
|
|
+ TYP. TYP. TO I&O MANUAL SUPPLEMENT FOR
|
|
|
+ BYPASS.
|
|
|
+ Alternate ISOMETRIC VIEW 5. DAMPERS SHIPPED LOOSE, FIELD
|
|
|
+ INSTALLATION REQUIRED
|
|
|
+ 8 1/8" Power Wiring 6"
|
|
|
+
|
|
|
+ Alternate Inlet 7/8" TYP.
|
|
|
+ Control Wiring
|
|
|
+ 20 1/8" Minimum FRONT VIEW RIGHT VIEW
|
|
|
+ Inlet 7/8" Service Area
|
|
|
+ (Doors can be
|
|
|
+ TOP VIEW Removed from Hinges.)
|
|
|
+
|
|
|
+ (OA/RA/BP) DAMPER OPTION (QTY.3)
|
|
|
+ (SHIPPED LOOSE)
|
|
|
+ SCALE 1:18
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 19 23 3/4" 2 7/8" BP Door-interlocked
|
|
|
+ Overall Typ.
|
|
|
+ Control Wiring Disconnect Switch
|
|
|
+ Inlet 1 1/8"
|
|
|
+ 12 7/8" 49 1/8" Case Pressure OA Isolation 10 3/8"
|
|
|
+ Ports (4) Typ. Damper
|
|
|
+ Wiring Conn.
|
|
|
+
|
|
|
+ EA OA
|
|
|
+ 3/4" -
|
|
|
+ 1 7/8" RA
|
|
|
+
|
|
|
+ 27 5/8" Typ. Face/Isolation
|
|
|
+ 8 7/8" 34 7/8" Case
|
|
|
+ Power Wiring 8 7/8"Damper
|
|
|
+ Inlet 7/8" 27 1/2"
|
|
|
+ Wiring Conn.
|
|
|
+ 38 3/8" Overall
|
|
|
+ FA RA
|
|
|
+
|
|
|
+ 8 5/8" 12" Typ. Leveling 10 3/8"
|
|
|
+ Feet (4)
|
|
|
+ RIGHT VIEW
|
|
|
+ LEFT VIEW FRONT VIEW
|
|
|
+
|
|
|
+ MAIoRdFeLOl: WHEC1OXINNFHIG[UBRypATaIsOsN] UNIT MOUNTING & APPLICATION
|
|
|
+ DAvraailawbleinags shToywpn ein :diUmennistioDn dirmaweinng.sion
|
|
|
+ Version: MAY18 Can be mounted in any orientation. Airstreams
|
|
|
+ can not be switched.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1XINH EEnneerrggyy RReeccoovveerryy VVeennttiillaattoorr
|
|
|
+ EECC MMoottoorr wOipthtioBnypass Economizer
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications
|
|
|
+ Static plate, heat and humidity transfer Fused disconnect
|
|
|
+EC MOTOR OPTION OPERATING RANGE
|
|
|
+ HE1XINH EC MOTOR Typical Airflow Range: 250-1,100 CFM Integrated programmable controls -
|
|
|
+ enhanced, premium
|
|
|
+ AHRI 1060 Certified Core: One L125-G5
|
|
|
+ Bypass economizer damper
|
|
|
+
|
|
|
+ Standard Features: (see bypass DIM drawing) -
|
|
|
+
|
|
|
+ Non-fused disconnect dry-bulb temperature controls (standard),
|
|
|
+
|
|
|
+ 24 VAC transformer/relay package enthalpy controls (option)
|
|
|
+
|
|
|
+ Cross-core differential pressure ports Low-leakage motorized isolation dampers -
|
|
|
+
|
|
|
+ Filters: OA, RA or both airstreams
|
|
|
+ Total qty. 2, MERV 8: 20" x 20" x 2" Qty. 2, Factory mounted filter alarms -
|
|
|
+
|
|
|
+ both airstreams
|
|
|
+
|
|
|
+ Unit Dimensions & Weight: Double wall construction
|
|
|
+
|
|
|
+ 54 3/4" L x 23 3/4" W x 35 3/4" H Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ 207-278 lbs., varies by option(s) Accessories:
|
|
|
+
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Filters - MERV 13, 2" (shipped loose)
|
|
|
+
|
|
|
+ 63" L x 30" W x 56" H Backdraft damper 12"
|
|
|
+
|
|
|
+ 325 lbs. Motorized isolation damper - both airstreams
|
|
|
+
|
|
|
+ Accessories box shipped loose on top of unit. Wall cap 12" - galvanized, paintable galvanneal
|
|
|
+
|
|
|
+ Motor(s): Potentiometer speed control - remote installed
|
|
|
+ Qty. 2, 0.5 HP ea., Direct drive EC blower/ Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ motor packages in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+
|
|
|
+ Electric duct heater - RH series (1-11.5 kW);
|
|
|
+
|
|
|
+ EK series (1–175 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+
|
|
|
+ HE1X-IN ECM (HIondriVre)ct gas-fired duct furnace - GH series
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ 1.75
|
|
|
+
|
|
|
+ Sample Points Depicted in Larger Dots
|
|
|
+
|
|
|
+ Airflow External Static Unit Power 1.50 992
|
|
|
+ (CFM) Pressure Consumption 1.25 918
|
|
|
+
|
|
|
+ (Inches Water (Watts)
|
|
|
+ Column)
|
|
|
+ 1029
|
|
|
+
|
|
|
+ 324 0.04 86 External Static Pressure (in. w.g.) 655 911
|
|
|
+
|
|
|
+ 446 TThheerrmmaall0PP.0ee7rrffoorrmmaannccee RRaattiinn1gg5ss0GG55 22001155..22..xxllssxx 1.00 HHEE11XX ((IIOOMM)) 1075
|
|
|
+ 871
|
|
|
+ 647 0.15 300 643
|
|
|
+
|
|
|
+ 794 0.24 564 0.75 1068
|
|
|
+
|
|
|
+ 392 599 852
|
|
|
+
|
|
|
+ 929 0.33 827
|
|
|
+
|
|
|
+ 1019 0.41 1042 386 583 1056
|
|
|
+ 359 572 839
|
|
|
+ 340
|
|
|
+ 300 0.11 91 0.50 1042
|
|
|
+ 173
|
|
|
+ 406 0.20 160 827
|
|
|
+
|
|
|
+ 579 0.42 359 0.25 164 322 564 818 1029 (Watts)
|
|
|
+ 97 160 300 560
|
|
|
+ 156
|
|
|
+ 713 0.65 599 89 153 273
|
|
|
+ 85 150
|
|
|
+ 828 0.89 871 0.00 148
|
|
|
+ 250 750 1000 1250
|
|
|
+ 500
|
|
|
+
|
|
|
+ 883 1.00 1075 Airflow (cfm)
|
|
|
+ = Actual tested sample points
|
|
|
+Note: Watts is for the entire unit.
|
|
|
+Note: Airflow performance includes effect of clean, standard filter CORE PERFORMANCE
|
|
|
+supplied with unit. AAiirrffllooww ((CCFFMM))
|
|
|
+
|
|
|
+ELECTRICAL DATA EffEffecetictvievneensess( (%)%) 90%220000 440000 660000 880000 11000000
|
|
|
+
|
|
|
+ Max. 90%
|
|
|
+ Overcurrent
|
|
|
+HP Volts HZ Phase FLA Min. Protection 7700%%
|
|
|
+ per Cir.
|
|
|
+ motor Amps Device
|
|
|
+
|
|
|
+0.5 120 60 Single 8.1 18.2 25 50%
|
|
|
+ 50%
|
|
|
+
|
|
|
+0.5 208-230 60 Single 4.8 10.8 15 3300%% At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+20 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1XINH Energy Recovery Ventilator EC Motor with Bypass Economizer
|
|
|
+
|
|
|
+ 21 3/4" Case 29" Bypass 12" Round Bypass Duct Connection ABBREVIATIONS
|
|
|
+ Damper (Direct Mount to Damper, By Others) EA: Exhaust Air to Outside
|
|
|
+ Conn. Location Door OA: Outside Air Intake
|
|
|
+ 12" Bypass Swing BP RA: Room Air to be Exhausted
|
|
|
+ Damper FA: Fresh Air to Inside
|
|
|
+ 49" Minimum Service Area EA OA BP: Bypass Air Intake
|
|
|
+ (Not Shown) (Doors can be Removed INSTALLATION ORIENTATION
|
|
|
+ 54 3/4" Overall FA RA Unit may be installed in any
|
|
|
+ 7 5/8" from Hinges.) orientation.
|
|
|
+ Face Damper NOTE
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ BYPASS AIRFLOW SCHEMATIC DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ FRONT VIEW 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ Door 3. UNITS WITH BYPASS WILL REQUIRE
|
|
|
+ Swing ADDITIONAL SPACE FOR THE
|
|
|
+ CONNECTION OF THE BYPASS DUCT
|
|
|
+ 12" 9" (BY OTHERS).
|
|
|
+ 4. FOR INSTALLATION DETAILS, REFER
|
|
|
+ TYP. TYP. TO I&O MANUAL SUPPLEMENT FOR
|
|
|
+ BYPASS.
|
|
|
+ Alternate ISOMETRIC VIEW 5. DAMPERS SHIPPED LOOSE, FIELD
|
|
|
+ INSTALLATION REQUIRED
|
|
|
+ 8 1/8" Power Wiring 6"
|
|
|
+
|
|
|
+ Alternate Inlet 7/8" TYP.
|
|
|
+ Control Wiring
|
|
|
+ 20 1/8" Minimum FRONT VIEW RIGHT VIEW
|
|
|
+ Inlet 7/8" Service Area
|
|
|
+ (Doors can be
|
|
|
+ TOP VIEW Removed from Hinges.)
|
|
|
+
|
|
|
+ (OA/RA/BP) DAMPER OPTION (QTY.3)
|
|
|
+ (SHIPPED LOOSE)
|
|
|
+ SCALE 1:18
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 21 23 3/4" 2 7/8" BP Door-interlocked
|
|
|
+ Overall Typ.
|
|
|
+ Control Wiring Disconnect Switch
|
|
|
+ Inlet 1 1/8"
|
|
|
+ 12 7/8" 49 1/8" Case Pressure OA Isolation 10 3/8"
|
|
|
+ Ports (4) Typ. Damper
|
|
|
+ Wiring Conn.
|
|
|
+
|
|
|
+ EA OA
|
|
|
+ 3/4" -
|
|
|
+ 1 7/8" RA
|
|
|
+
|
|
|
+ 27 5/8" Typ. Face/Isolation
|
|
|
+ 8 7/8" 34 7/8" Case
|
|
|
+ Power Wiring 8 7/8"Damper
|
|
|
+ Inlet 7/8" 27 1/2"
|
|
|
+ Wiring Conn.
|
|
|
+ 38 3/8" Overall
|
|
|
+ FA RA
|
|
|
+
|
|
|
+ 8 5/8" 12" Typ. Leveling 10 3/8"
|
|
|
+ Feet (4)
|
|
|
+ RIGHT VIEW
|
|
|
+ LEFT VIEW FRONT VIEW
|
|
|
+
|
|
|
+ MAIoRdFeLOl: WHEC1OXINNFHIG[UBRypATaIsOsN] UNIT MOUNTING & APPLICATION
|
|
|
+ DAvraailawbleinags shToywpn ein :diUmennistioDn dirmaweinng.sion
|
|
|
+ Version: MAY18 Can be mounted in any orientation. Airstreams
|
|
|
+ can not be switched.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1XINV Energy Recovery Ventilator
|
|
|
+ Standarrdd & Bypass Economizer Option
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS Options:
|
|
|
+ Qty. 2, Variable Speed/ECM - Direct Drive Motors
|
|
|
+Download specification at: Ventilation Type:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer (see HE1XINV EC Motor submittal) -
|
|
|
+ 0.5 HP 120V/1Ph/60HZ,
|
|
|
+ Typical Airflow Range: 250-925 CFM 0.5 HP 208-230V/1Ph/60HZ
|
|
|
+ Independent blower control
|
|
|
+ AHRI 1060 Certified Core: One L125-G5 Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ Standard Features: enhanced, premium
|
|
|
+ Non-fused disconnect Bypass economizer damper
|
|
|
+ 24 VAC transformer/relay package (see bypass DIM drawing) -
|
|
|
+ Cross-core differential pressure ports dry-bulb temperature controls (standard),
|
|
|
+ enthalpy controls (option)
|
|
|
+ Filters: Low-leakage motorized isolation dampers -
|
|
|
+ Total qty. 2, MERV 8: 20" x 20" x 2" OA, RA or both airstreams
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+ Unit Dimensions & Weight: both airstreams
|
|
|
+ 40 1/2" L x 23 3/4" W x 50 3/4" H Double wall construction
|
|
|
+ 201-272 lbs., varies by option(s) Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Accessories:
|
|
|
+ 30" L x 42" W x 71" H Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 325 lbs. Backdraft damper 12"
|
|
|
+ Accessories box shipped loose on top of unit. Motorized isolation damper - both airstreams
|
|
|
+ Wall cap 12" - galvanized, paintable galvanneal
|
|
|
+ Motor(s): Solid state speed control kit - 115V,
|
|
|
+ Qty. 2, 0.75 HP ea., Direct drive blower/standard
|
|
|
+ 208-230V (1 required per motor)
|
|
|
+ motor packages Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ Thermal Performance Ratings G5 2015.2.xlsx HE1X (IOM) in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - RH series (1-11.5 kW);
|
|
|
+
|
|
|
+ EK series (1–175 kW);
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+Motor HP External Static Pressure (Inches Water Column)
|
|
|
+
|
|
|
+Phase 0.0 0.25 0.5 0.75 0.9 1.25 1.5
|
|
|
+
|
|
|
+ 0.75 970 CFM 925 CFM 860 CFM 795 CFM 750 CFM 635 CFM 480 CFM
|
|
|
+Single Phase 1,490 Watts 1,375 Watts 1,270 Watts 1,160 Watts 1,090 Watts 950 Watts 825 Watts
|
|
|
+
|
|
|
+ 0.75 970 CFM 925 CFM 860 CFM 795 CFM 750 CFM 635 CFM 480 CFM
|
|
|
+Three Phase 1,246 Watts 1,158 Watts 1,039 Watts 928 Watts 856 Watts 691 Watts 509 Watts
|
|
|
+
|
|
|
+Note: Watts is for the entire unit (2 motors).
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ FLA Min. Max. Airflow (CFM)
|
|
|
+ HP Volts HZ Phase per Cir. Overcurrent
|
|
|
+ Protection Effectiveness (%) 200 400 600 800 1000
|
|
|
+ motor Amps 90%
|
|
|
+ Device
|
|
|
+ 0.75 120 60 Single 9.0 20.3 25 70%
|
|
|
+ 0.75 208-230 60 Single 4.5 10.1
|
|
|
+ 0.75 277 60 Single 3.9 8.8 15 50%
|
|
|
+ 0.75 208-230 60 Three 1.7-2.3 5.2
|
|
|
+ 0.75 460 60 Three 1.15 2.6 15 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+ 15
|
|
|
+
|
|
|
+ 15
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+22 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1XINV Energy Recovery Ventilator Standaarrdd or EC Motor Option ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to Outside
|
|
|
+ 23 3/4" OA: Outside Air Intake
|
|
|
+ Overall RA: Room Air to be Exhausted
|
|
|
+ FA: Fresh Air to Inside
|
|
|
+ 40 3/8" Overall 12" 9" INSTALLATION ORIENTATION
|
|
|
+ Unit may be installed in any
|
|
|
+ TYP. ISOMETRIC VIEW TYP. orientation.
|
|
|
+ NOTE
|
|
|
+ 6" 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ TYP. DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3. DAMPERS SHIPPED LOOSE, FIELD
|
|
|
+ INSTALLATION REQUIRED
|
|
|
+
|
|
|
+ FRONT VIEW RIGHT VIEW17 3/4"
|
|
|
+ 49" Minimum
|
|
|
+ TOP VIEW (OA/RA) DAMPER OPTION (QTY. 2) Service Area 20 1/8" Minimum
|
|
|
+ (SHIPPED LOOSE) (Doors can be Service Area
|
|
|
+ SCALE 1:16 Removed from Hinges.) (Doors can be
|
|
|
+
|
|
|
+ Removed from
|
|
|
+ Hinges.)
|
|
|
+
|
|
|
+ 10 3/8" Typ. 12" Typ. Pressure 34 7/8" Case 2 7/8" Typ. 29" 21 3/4"
|
|
|
+ Ports (4) Typ.
|
|
|
+ RA Isolation OA Case
|
|
|
+ Damper RA
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 23 Wiring Conn. Door
|
|
|
+ Swing
|
|
|
+
|
|
|
+ 50 3/4" Overall 40 3/4" Typ. 49 1/8" Case FA EA Door
|
|
|
+ 49 7/8" Typ. Swing
|
|
|
+
|
|
|
+ 16 1/4"
|
|
|
+ Typ.
|
|
|
+
|
|
|
+ 12 7/8" OA Isolation 8 5/8"
|
|
|
+ Power and Damper
|
|
|
+ Control Wiring 3/4" - 1 7/8" Typ. Door-Interlocked Wiring Conn.
|
|
|
+ Inlets 7/8" Disconnect Switch
|
|
|
+ Leveling
|
|
|
+ LEFT VIEW Feet (4)
|
|
|
+
|
|
|
+ DMAAvIarRoialaFdbwLleeOainslW:sghHoCwTEOny1iNnpXdFeIimNIG:eVnUUsiRonnAidtTraDIwOiinNmg. ension FRONT VIEW RIGHT VIEW
|
|
|
+ Version: MAY18
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+ Can be mounted in any orientation. RA/EA airstream
|
|
|
+ can be switched with OA/FA airstream unless
|
|
|
+ certain options are selected.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1XINV Energy Recovery Ventilator
|
|
|
+ EC Motor Option
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications
|
|
|
+EC MOTOR OPTION OPERATING RANGE Static plate, heat and humidity transfer Fused disconnect
|
|
|
+
|
|
|
+ Typical Airflow Range: 250-1,100 CFM Integrated programmable controls -
|
|
|
+ enhanced, premium
|
|
|
+
|
|
|
+ AHRI 1060 Certified Core: One L125-G5 Bypass economizer damper
|
|
|
+
|
|
|
+ Standard Features: (see bypass DIM drawing) -
|
|
|
+ Non-fused disconnect dry-bulb temperature controls (standard),
|
|
|
+ 24 VAC transformer/relay package enthalpy controls (option)
|
|
|
+ Cross-core differential pressure ports Low-leakage motorized isolation dampers -
|
|
|
+ OA, RA or both airstreams
|
|
|
+ Filters: Qty. 2, Factory mounted filter alarms -
|
|
|
+ Total qty. 2, MERV 8: 20" x 20" x 2" both airstreams
|
|
|
+
|
|
|
+ Unit Dimensions & Weight: Double wall construction
|
|
|
+ 40 1/2" L x 23 3/4" W x 50 3/4" H Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ 204-275 lbs., varies by option(s) Accessories:
|
|
|
+
|
|
|
+ Shipping Dimensions & Weight (on pallet): Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 30" L x 42" W x 71" H Backdraft damper 12"
|
|
|
+ 325 lbs. Motorized isolation damper - both airstreams
|
|
|
+ Accessories box shipped loose on top of unit. Wall cap 12" - galvanized, paintable galvanneal
|
|
|
+ Potentiometer speed control - remote installed
|
|
|
+ Motor(s): Digital time clock - wall mount (TC7D-W),
|
|
|
+ Qty. 2, 0.5 HP ea., Direct drive EC blower/
|
|
|
+ in exterior enclosure (TC7D-E)
|
|
|
+ motor packages Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+
|
|
|
+ Electric duct heater - RH series (1-11.5 kW);
|
|
|
+
|
|
|
+ EK series (1–175 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+
|
|
|
+ HE1X-IN ECM (InHdoi(r5er0cV-t4)g0a0s-MfirBeHd)d, uincsttfaullrendacdeow- nGsHtrseearmiesof any fans
|
|
|
+
|
|
|
+ HE1XINV EC MOTOR 1.75
|
|
|
+
|
|
|
+ Sample Points Depicted in Larger Dots
|
|
|
+
|
|
|
+ Airflow External Static Unit Power 1.50 992
|
|
|
+ (CFM) Pressure Consumption 1.25 918
|
|
|
+
|
|
|
+ (Inches Water (Watts)
|
|
|
+ Column)
|
|
|
+ 1029
|
|
|
+
|
|
|
+ 324 0.04 86 External Static Pressure (in. w.g.) 655 911
|
|
|
+
|
|
|
+ 446 Thermal0P.0e7rformance Ratin1g5s0G5 2015.2.xlsx 1.00 HE1X (IOM) 1075
|
|
|
+ Thermal Performance Ratings G5 2015.2.xlsx HE1X (IOM) 871
|
|
|
+ 647 0.15 300
|
|
|
+ 643
|
|
|
+
|
|
|
+ 794 0.24 564 1068
|
|
|
+
|
|
|
+ 929 0.33 827 0.75 392 599 852
|
|
|
+
|
|
|
+ 1019 0.41 1042 386 583 1056
|
|
|
+ 359 572 839
|
|
|
+ 340
|
|
|
+ 300 0.11 91 0.50 1042
|
|
|
+ 173
|
|
|
+ 406 0.20 160 827
|
|
|
+
|
|
|
+ 579 0.42 359 0.25 164 322 564 818 1029 (Watts)
|
|
|
+ 97 160 300 560
|
|
|
+ 156
|
|
|
+ 713 0.65 599 89 153 273
|
|
|
+ 85 150
|
|
|
+ 828 0.89 871 0.00 148
|
|
|
+ 250
|
|
|
+ 500 750 1000 1250
|
|
|
+
|
|
|
+ 883 1.00 1075 Airflow (cfm)
|
|
|
+
|
|
|
+ = Actual tested sample points
|
|
|
+
|
|
|
+Note: Watts is for the entire unit. CORE PERFORMANCE
|
|
|
+Note: Airflow performance includes effect of clean, standard filter
|
|
|
+supplied with unit. AAiirrffllooww ((CCFFMM))
|
|
|
+
|
|
|
+ EffEfefcetictvievneensess (s (%)%) 200 400 600 800 1000
|
|
|
+ELECTRICAL DATA 90%200 400 600 800 1000
|
|
|
+
|
|
|
+ Max. 90%
|
|
|
+ Overcurrent
|
|
|
+HP Volts HZ Phase FLA Min. Protection 70%
|
|
|
+ per Cir. 70%
|
|
|
+ motor Amps Device
|
|
|
+
|
|
|
+0.5 120 60 Single 8.1 18.2 25 50%
|
|
|
+ 50%
|
|
|
+
|
|
|
+0.5 208-230 60 Single 4.8 10.8 15 30%
|
|
|
+ 30% At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+24 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1XINV Energy Recovery Ventilator SEtCanMdoatrodr oOrpEtiConMotor Option ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to Outside
|
|
|
+ 23 3/4" OA: Outside Air Intake
|
|
|
+ Overall RA: Room Air to be Exhausted
|
|
|
+ FA: Fresh Air to Inside
|
|
|
+ 40 3/8" Overall 12" 9" INSTALLATION ORIENTATION
|
|
|
+ Unit may be installed in any
|
|
|
+ TYP. ISOMETRIC VIEW TYP. orientation.
|
|
|
+ NOTE
|
|
|
+ 6" 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ TYP. DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3. DAMPERS SHIPPED LOOSE, FIELD
|
|
|
+ INSTALLATION REQUIRED
|
|
|
+
|
|
|
+ FRONT VIEW RIGHT VIEW17 3/4"
|
|
|
+ 49" Minimum
|
|
|
+ TOP VIEW (OA/RA) DAMPER OPTION (QTY. 2) Service Area 20 1/8" Minimum
|
|
|
+ (SHIPPED LOOSE) (Doors can be Service Area
|
|
|
+ SCALE 1:16 Removed from Hinges.) (Doors can be
|
|
|
+
|
|
|
+ Removed from
|
|
|
+ Hinges.)
|
|
|
+
|
|
|
+ 10 3/8" Typ. 12" Typ. Pressure 34 7/8" Case 2 7/8" Typ. 29" 21 3/4"
|
|
|
+ Ports (4) Typ.
|
|
|
+ RA Isolation OA Case
|
|
|
+ Damper RA
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 25 Wiring Conn. Door
|
|
|
+ Swing
|
|
|
+
|
|
|
+ 50 3/4" Overall 40 3/4" Typ. 49 1/8" Case FA EA Door
|
|
|
+ 49 7/8" Typ. Swing
|
|
|
+
|
|
|
+ 16 1/4"
|
|
|
+ Typ.
|
|
|
+
|
|
|
+ 12 7/8" OA Isolation 8 5/8"
|
|
|
+ Power and Damper
|
|
|
+ Control Wiring 3/4" - 1 7/8" Typ. Door-Interlocked Wiring Conn.
|
|
|
+ Inlets 7/8" Disconnect Switch
|
|
|
+ Leveling
|
|
|
+ LEFT VIEW Feet (4)
|
|
|
+
|
|
|
+ DMAAvIarRoialaFdbwLleeOainslW:sghHoCwTEOny1iNnpXdFeIimNIG:eVnUUsiRonnAidtTraDIwOiinNmg. ension FRONT VIEW RIGHT VIEW
|
|
|
+ Version: MAY18
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+ Can be mounted in any orientation. RA/EA airstream
|
|
|
+ can be switched with OA/FA airstream unless
|
|
|
+ certain options are selected.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1XINV Energy Recovery Ventilator
|
|
|
+ Standard with Bypass Economizer
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS Options:
|
|
|
+ Qty. 2, Variable Speed/ECM - Direct Drive Motors
|
|
|
+Download specification at: Ventilation Type:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer (see HE1XINV EC Motor submittal) -
|
|
|
+ 0.5 HP 120V/1Ph/60HZ,
|
|
|
+ Typical Airflow Range: 250-925 CFM 0.5 HP 208-230V/1Ph/60HZ
|
|
|
+ Independent blower control
|
|
|
+ AHRI 1060 Certified Core: One L125-G5 Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ Standard Features: enhanced, premium
|
|
|
+ Non-fused disconnect Bypass economizer damper
|
|
|
+ 24 VAC transformer/relay package (see bypass DIM drawing) -
|
|
|
+ Cross-core differential pressure ports dry-bulb temperature controls (standard),
|
|
|
+ enthalpy controls (option)
|
|
|
+ Filters: Low-leakage motorized isolation dampers -
|
|
|
+ Total qty. 2, MERV 8: 20" x 20" x 2" OA, RA or both airstreams
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+ Unit Dimensions & Weight: both airstreams
|
|
|
+ 40 1/2" L x 23 3/4" W x 50 3/4" H Double wall construction
|
|
|
+ 201-272 lbs., varies by option(s) Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Accessories:
|
|
|
+ 30" L x 42" W x 71" H Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 325 lbs. Backdraft damper 12"
|
|
|
+ Accessories box shipped loose on top of unit. Motorized isolation damper - both airstreams
|
|
|
+ Wall cap 12" - galvanized, paintable galvanneal
|
|
|
+ Motor(s): Solid state speed control kit - 115V,
|
|
|
+ Qty. 2, 0.75 HP ea., Direct drive blower/standard
|
|
|
+ 208-230V (1 required per motor)
|
|
|
+ motor packages Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ Thermal Performance Ratings G5 2015.2.xlsx HE1X (IOM) in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - RH series (1-11.5 kW);
|
|
|
+
|
|
|
+ EK series (1–175 kW);
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+Motor HP External Static Pressure (Inches Water Column)
|
|
|
+
|
|
|
+Phase 0.0 0.25 0.5 0.75 0.9 1.25 1.5
|
|
|
+
|
|
|
+ 0.75 970 CFM 925 CFM 860 CFM 795 CFM 750 CFM 635 CFM 480 CFM
|
|
|
+Single Phase 1,490 Watts 1,375 Watts 1,270 Watts 1,160 Watts 1,090 Watts 950 Watts 825 Watts
|
|
|
+
|
|
|
+ 0.75 970 CFM 925 CFM 860 CFM 795 CFM 750 CFM 635 CFM 480 CFM
|
|
|
+Three Phase 1,246 Watts 1,158 Watts 1,039 Watts 928 Watts 856 Watts 691 Watts 509 Watts
|
|
|
+
|
|
|
+Note: Watts is for the entire unit (2 motors).
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ FLA Min. Max. Airflow (CFM)
|
|
|
+ HP Volts HZ Phase per Cir. Overcurrent
|
|
|
+ Protection Effectiveness (%) 200 400 600 800 1000
|
|
|
+ motor Amps 90%
|
|
|
+ Device
|
|
|
+ 0.75 120 60 Single 9.0 20.3 25 70%
|
|
|
+ 0.75 208-230 60 Single 4.5 10.1
|
|
|
+ 0.75 277 60 Single 3.9 8.8 15 50%
|
|
|
+ 0.75 208-230 60 Three 1.7-2.3 5.2
|
|
|
+ 0.75 460 60 Three 1.15 2.6 15 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+ 15
|
|
|
+
|
|
|
+ 15
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+26 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1XINV Energy Recovery Ventilator SWtaitnhdBayrdpawsisthEBcyopnaosms iEzecronOopmtiiozner(Standard & EC Motor)
|
|
|
+
|
|
|
+ 26 1/2" Overall ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to Outside
|
|
|
+ 12" Round Bypass Duct Connection OA: Outside Air Intake
|
|
|
+ (Direct Mount to Damper, By Others) RA: Room Air to be Exhausted
|
|
|
+ FA: Fresh Air to Inside
|
|
|
+ 40 3/8" Overall 12" ISOMETRIC VIEW 9" BP BP: Bypass Air Intake
|
|
|
+ 27 5/8" TYP. INSTALLATION ORIENTATION
|
|
|
+ TYP. Bypass Unit may be installed in any
|
|
|
+ Face Damper orientation.
|
|
|
+ NOTE
|
|
|
+ Damper EA 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ RA NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ 6" TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3. UNITS WITH BYPASS WILL REQUIRE
|
|
|
+ TYP. BYPASS AIRFLOW SCHEMATIC ADDITIONAL SPACE FOR THE
|
|
|
+ CONNECTION OF THE BYPASS DUCT
|
|
|
+ TOP VIEW FRONT VIEW RIGHT VIEW TOP VIEW (BY OTHERS).
|
|
|
+ (OA/FA Airstream Not Shown) 4. FOR INSTALLATION DETAILS, REFER
|
|
|
+ 10 3/8" Typ. (OA/RA/BP) DAMPER OPTION (QTY.3) TO I&O MANUAL SUPPLEMENT FOR
|
|
|
+ (SHIPPED LOOSE) BYPASS.
|
|
|
+ RA SCALE 1:18 5. DAMPERS SHIPPED LOOSE, FIELD
|
|
|
+ Face/Isolation INSTALLATION REQUIRED
|
|
|
+ Damper
|
|
|
+ Wiring Conn. 12" Typ. Pressure 34 7/8" Case Bypass 20 1/8" Minimum 29" 21 3/4" Case
|
|
|
+ Ports (4) Typ. Location Service Area
|
|
|
+ BP (Doors can be
|
|
|
+ 2 7/8" Removed from
|
|
|
+ Typ. Hinges.)
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 27 RA OA 49" Minimum Service AreaDoor
|
|
|
+ (Doors can be RemovedSwing
|
|
|
+
|
|
|
+ 16 1/4" Typ. 49 1/8" Case FA EA from Hinges.)Door
|
|
|
+ 40 3/4" Typ. 9 3/4"Swing
|
|
|
+ 50 3/4" Overall
|
|
|
+ Conn. Location
|
|
|
+ 12" Bypass 12 7/8" Power and 3/4" - Door-Interlocked Leveling OA Isolation 8 5/8"
|
|
|
+ Control Wiring 1 7/8" Disconnect Switch Feet (4) Damper
|
|
|
+ Damper LEFT VIEW Inlets 7/8" Wiring Conn.
|
|
|
+ (Not Shown) Typ.
|
|
|
+
|
|
|
+ FRONT VIEW RIGHT VIEW
|
|
|
+
|
|
|
+ MAoIRdFLeOl:WHEC1OXNIFNIGVU[RBAyTpIOaNss] UNIT MOUNTING & APPLICATION
|
|
|
+ DArvaailawbleinasgshoTwynpinedi:mUensniointdDrawiminge. nsion
|
|
|
+ Version: MAY18 Can be mounted in any orientation. Airstreams
|
|
|
+ can not be switched.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1XINV Energy Recovery Ventilator
|
|
|
+ EC Motoorr wOipthtioBnypass Economizer
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+ Ventilation Type: Options:
|
|
|
+
|
|
|
+ Static plate, heat and humidity transfer Fused disconnect
|
|
|
+
|
|
|
+ Typical Airflow Range: 250-1,100 CFM Integrated programmable controls -
|
|
|
+ enhanced, premium
|
|
|
+
|
|
|
+ AHRI 1060 Certified Core: One L125-G5 Bypass economizer damper
|
|
|
+
|
|
|
+ Standard Features: (see bypass DIM drawing) -
|
|
|
+ Non-fused disconnect dry-bulb temperature controls (standard),
|
|
|
+ 24 VAC transformer/relay package enthalpy controls (option)
|
|
|
+ Cross-core differential pressure ports Low-leakage motorized isolation dampers -
|
|
|
+ OA, RA or both airstreams
|
|
|
+ Filters: Qty. 2, Factory mounted filter alarms -
|
|
|
+ Total qty. 2, MERV 8: 20" x 20" x 2" both airstreams
|
|
|
+
|
|
|
+ Unit Dimensions & Weight: Double wall construction
|
|
|
+ 40 1/2" L x 23 3/4" W x 50 3/4" H Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ 204-275 lbs., varies by option(s) Accessories:
|
|
|
+
|
|
|
+ Shipping Dimensions & Weight (on pallet): Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 30" L x 42" W x 71" H Backdraft damper 12"
|
|
|
+ 325 lbs. Motorized isolation damper - both airstreams
|
|
|
+ Accessories box shipped loose on top of unit. Wall cap 12" - galvanized, paintable galvanneal
|
|
|
+ Potentiometer speed control - remote installed
|
|
|
+ Motor(s): Digital time clock - wall mount (TC7D-W),
|
|
|
+ Qty. 2, 0.5 HP ea., Direct drive EC blower/
|
|
|
+ in exterior enclosure (TC7D-E)
|
|
|
+ motor packages Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+Download specification at: wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+renewaire.com/specifications
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+EC MOTOR OPTION OPERATING RANGE
|
|
|
+ HE1XINV EC MOTOR duct mount (IAQ-D)
|
|
|
+
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+
|
|
|
+ Electric duct heater - RH series (1-11.5 kW);
|
|
|
+
|
|
|
+ EK series (1–175 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+ HE1X-IN ECM (H or(5V0) -400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ 1.75
|
|
|
+
|
|
|
+ Sample Points Depicted in Larger Dots
|
|
|
+
|
|
|
+ Airflow External Static Unit Power 1.50 992
|
|
|
+ (CFM) Pressure Consumption 1.25 918
|
|
|
+
|
|
|
+ (Inches Water (Watts)
|
|
|
+ Column)
|
|
|
+ 1029
|
|
|
+
|
|
|
+ 324 0.04 86 External Static Pressure (in. w.g.) 655 911
|
|
|
+
|
|
|
+ 446 TThheerrmmaall0PP.0ee7rrffoorrmmaannccee RRaattiinn1gg5ss0GG55 22001155..22..xxllssxx 1.00 HHEE11XX ((IIOOMM)) 1075
|
|
|
+ 871
|
|
|
+ 647 0.15 300 643
|
|
|
+
|
|
|
+ 794 0.24 564 1068
|
|
|
+
|
|
|
+ 0.75 392 599 852
|
|
|
+
|
|
|
+ 929 0.33 827
|
|
|
+
|
|
|
+ 1019 0.41 1042 386 583 1056
|
|
|
+ 359 572 839
|
|
|
+ 340
|
|
|
+ 300 0.11 91 0.50 1042
|
|
|
+ 173
|
|
|
+ 406 0.20 160 827
|
|
|
+
|
|
|
+ 579 0.42 359 0.25 164 322 564 818 1029 (Watts)
|
|
|
+ 97 160 300 560
|
|
|
+ 156
|
|
|
+ 713 0.65 599 89 153 273
|
|
|
+ 85 150
|
|
|
+ 828 0.89 871 0.00 148
|
|
|
+ 250 750 1000 1250
|
|
|
+ 500
|
|
|
+
|
|
|
+ 883 1.00 1075 Airflow (cfm)
|
|
|
+
|
|
|
+Note: Watts is for the entire unit. = Actual tested sample points
|
|
|
+Note: Airflow performance includes effect of clean, standard filter
|
|
|
+supplied with unit. CORE PERFORMANCE
|
|
|
+
|
|
|
+ AAiirrffllooww ((CCFFMM))
|
|
|
+
|
|
|
+ELECTRICAL DATA EffEfefcetictvievneenses (s (%)%) 200 400 600 800 1000
|
|
|
+ 90%200 400 600 800 1000
|
|
|
+
|
|
|
+ Max. 90%
|
|
|
+ Overcurrent
|
|
|
+HP Volts HZ Phase FLA Min. Protection 70%
|
|
|
+ per Cir. 70%
|
|
|
+ motor Amps Device
|
|
|
+
|
|
|
+0.5 120 60 Single 8.1 18.2 25 50%
|
|
|
+ 50%
|
|
|
+
|
|
|
+0.5 208-230 60 Single 4.8 10.8 15 30%
|
|
|
+ 30% At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+28 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1XINV Energy Recovery Ventilator W ECithMBotyoprawssithEcBoynpoasmsizEecroOnopmtioizne(rStandard & EC Motor)
|
|
|
+
|
|
|
+ 26 1/2" Overall ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to Outside
|
|
|
+ 12" Round Bypass Duct Connection OA: Outside Air Intake
|
|
|
+ (Direct Mount to Damper, By Others) RA: Room Air to be Exhausted
|
|
|
+ FA: Fresh Air to Inside
|
|
|
+ 40 3/8" Overall 12" ISOMETRIC VIEW 9" BP BP: Bypass Air Intake
|
|
|
+ 27 5/8" TYP. INSTALLATION ORIENTATION
|
|
|
+ TYP. Bypass Unit may be installed in any
|
|
|
+ Face Damper orientation.
|
|
|
+ NOTE
|
|
|
+ Damper EA 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ RA NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ 6" TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3. UNITS WITH BYPASS WILL REQUIRE
|
|
|
+ TYP. BYPASS AIRFLOW SCHEMATIC ADDITIONAL SPACE FOR THE
|
|
|
+ CONNECTION OF THE BYPASS DUCT
|
|
|
+ TOP VIEW FRONT VIEW RIGHT VIEW TOP VIEW (BY OTHERS).
|
|
|
+ (OA/FA Airstream Not Shown) 4. FOR INSTALLATION DETAILS, REFER
|
|
|
+ 10 3/8" Typ. (OA/RA/BP) DAMPER OPTION (QTY.3) TO I&O MANUAL SUPPLEMENT FOR
|
|
|
+ (SHIPPED LOOSE) BYPASS.
|
|
|
+ RA SCALE 1:18 5. DAMPERS SHIPPED LOOSE, FIELD
|
|
|
+ Face/Isolation INSTALLATION REQUIRED
|
|
|
+ Damper
|
|
|
+ Wiring Conn. 12" Typ. Pressure 34 7/8" Case Bypass 20 1/8" Minimum 29" 21 3/4" Case
|
|
|
+ Ports (4) Typ. Location Service Area
|
|
|
+ BP (Doors can be
|
|
|
+ 2 7/8" Removed from
|
|
|
+ Typ. Hinges.)
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 29 RA OA 49" Minimum Service AreaDoor
|
|
|
+ (Doors can be RemovedSwing
|
|
|
+
|
|
|
+ 16 1/4" Typ. 49 1/8" Case FA EA from Hinges.)Door
|
|
|
+ 40 3/4" Typ. 9 3/4"Swing
|
|
|
+ 50 3/4" Overall
|
|
|
+ Conn. Location
|
|
|
+ 12" Bypass 12 7/8" Power and 3/4" - Door-Interlocked Leveling OA Isolation 8 5/8"
|
|
|
+ Control Wiring 1 7/8" Disconnect Switch Feet (4) Damper
|
|
|
+ Damper LEFT VIEW Inlets 7/8" Wiring Conn.
|
|
|
+ (Not Shown) Typ.
|
|
|
+
|
|
|
+ FRONT VIEW RIGHT VIEW
|
|
|
+
|
|
|
+ MAoIRdFLeOl:WHEC1OXNIFNIGVU[RBAyTpIOaNss] UNIT MOUNTING & APPLICATION
|
|
|
+ DArvaailawbleinasgshoTwynpinedi:mUensniointdDrawiminge. nsion
|
|
|
+ Version: MAY18 Can be mounted in any orientation. Airstreams
|
|
|
+ can not be switched.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1XRT Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+ROOFTOP UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Qty. 2, Variable Speed/ECM - Direct Drive Motors
|
|
|
+ Typical Airflow Range: 250-870 CFM
|
|
|
+ AHRI 1060 Certified Core: One L125-G5 (see HE1XRT EC Motor submittal) -
|
|
|
+ Standard Features: 0.5 HP 120V/1Ph/60HZ,
|
|
|
+ Non-fused disconnect 0.5 HP 208-230V/1Ph/60HZ
|
|
|
+ 24 VAC transformer/relay package Independent blower control
|
|
|
+ Cross-core differential pressure ports Onboard variable frequency drives (VFDs) -
|
|
|
+ Filters: one or both airstreams
|
|
|
+ Total qty. 2, MERV 8: 20" x 20" x 2" Fused disconnect
|
|
|
+ Unit Dimensions & Weight: Integrated programmable controls -
|
|
|
+ 81" L x 40 1/4" W x 44" H enhanced, premium
|
|
|
+ 243-346 lbs., varies by option(s) Class 1 low leakage motorized isolation dampers -
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): OA, RA or both airstreams
|
|
|
+ 96" L x 47" W x 50" H Qty. 2, Factory mounted filter alarms -
|
|
|
+ 441 lbs. both airstreams
|
|
|
+ Motor(s): Double wall construction
|
|
|
+ Qty. 2, 0.75 HP ea., Direct drive blower/standard Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ motor packages Accessories:
|
|
|
+ Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Thermal Performance Ratings G5 2015.2.xlsx Backdraft damper 12"
|
|
|
+ Solid state speed control kit - 115V,
|
|
|
+
|
|
|
+ 208-230V (1 required per motor)
|
|
|
+ Roof curb - standard 14"
|
|
|
+ Curb wind clip
|
|
|
+ Engineered combo curb for Trane RTU
|
|
|
+ Engineered combo curb for Carrier RTU
|
|
|
+ Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), insHtaEll1eXd d(IoOwMns)tream of any fans
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+ Motor HP External Static Pressure (Inches Water Column)
|
|
|
+ Phase
|
|
|
+ 0.0 0.5 1.0 1.25 1.45 1.75
|
|
|
+
|
|
|
+ 0.75 950 CFM 820 CFM 730 CFM 650 CFM 560 CFM 250 CFM
|
|
|
+Single Phase 1,630 Watts 1,475 Watts 1,385 Watts 1,300 Watts 1,220 Watts 1,080 Watts
|
|
|
+
|
|
|
+ 0.75 950 CFM 820 CFM 730 CFM 650 CFM 560 CFM 250 CFM
|
|
|
+Three Phase 1,430 Watts 1,255 Watts 1,155 Watts 1,060 Watts 955 Watts 685 Watts
|
|
|
+
|
|
|
+Note: Watts is for the entire unit (2 motors).
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+ Standard Electrical Specifications
|
|
|
+ Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+ Min. Max. Min. Max. Effectiveness (%) 200 400 600 800 1000
|
|
|
+ Cir. Overcurrent Cir. Overcurrent
|
|
|
+HP Volts HZ Phase FLA Amps Protection FLA Amps Protection 90%
|
|
|
+ per motor per motor
|
|
|
+ Device Device
|
|
|
+ 25 70%
|
|
|
+
|
|
|
+0.75 120 60 Single 9.0 20.3 15
|
|
|
+
|
|
|
+0.75 208-230 60 Single 4.5 10.1 15 50%
|
|
|
+
|
|
|
+0.75 277 60 Single 3.9 8.8 15 30%
|
|
|
+ At AHRI 1060 standard conditions.
|
|
|
+0.75 208-230 60 Three 1.7-2.3 5.2 15 1.7-2.3 5.7 15 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+0.75 460 60 Three 1.15 2.6 1.15 2.8 15
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+30 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1XRT (RTV/RTR) Energy Recovery Ventilator Standaarrdd or EC Motor Option
|
|
|
+
|
|
|
+ 22 5/8" RA Damper ABBREVIATIONS
|
|
|
+ Case Location EA: Exhaust Air to outside
|
|
|
+ (Optional) OA: Outside Air intake
|
|
|
+ RA (Recessed 3/4") CURB 1X RA: Room Air to be exhausted
|
|
|
+ 10 1/4" X 12 1/2" FA: Fresh Air to inside
|
|
|
+ 35 1/4" Minimum 14 1/2" RTV: Rooftop Vertical RA & FA
|
|
|
+ Opening Service Area RTR: Rooftop Vertical RA Only
|
|
|
+ RA INSTALLATION ORIENTATION
|
|
|
+ 51" Case Door 14 1/4" Unit must be installed in orientation
|
|
|
+ 10 3/4" 10 1/4" 10 1/8" Swing 10 1/8" 44" I.D. shown.
|
|
|
+ 61 1/8" Minimum NOTE:
|
|
|
+ Service Area 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ 47 3/4" O.D. DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 7 1/2" A A 14 1/4" CURB CROSS-SECTION A-A (TYP.)
|
|
|
+
|
|
|
+ Door FA
|
|
|
+ Swing
|
|
|
+ FA (RTV) 1 1/2" X 1/4" 1 7/8"
|
|
|
+ 7 1/4" X 6 1/8" Neoprene Gasket
|
|
|
+ Opening
|
|
|
+ 18 1/4" O.D. 3/4" X 3 1/2" 44"
|
|
|
+ TOP VIEW Wooden Nailer Overall
|
|
|
+ TOP VIEW
|
|
|
+ 3" 14"
|
|
|
+
|
|
|
+ SECTION A-A
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 31 EA Outlet 81" Overall 2" 40 1/4" Overall
|
|
|
+ at Back Typ.
|
|
|
+ 45 3/4" 20 1/8"
|
|
|
+ E-Box Lift Lugs OA Lift Lugs
|
|
|
+
|
|
|
+ EA 21 1/2" Disconnect Pressure Ports
|
|
|
+ Wiring Switch (4) Typ.
|
|
|
+ FA (RTR)
|
|
|
+ 16"X12" 41" 6 5/8"
|
|
|
+ Duct Receiving Case
|
|
|
+ Flange
|
|
|
+ FA RTR OA Damper
|
|
|
+ ONLY Location
|
|
|
+
|
|
|
+ (Optional)
|
|
|
+
|
|
|
+ 1 1/2" CL 5 5/8" Power In FA RA
|
|
|
+
|
|
|
+ CL 15 1/4" CL 2 1/2" Control In RTV
|
|
|
+ Wiring (2) 7/8" holes for ONLY
|
|
|
+ wiring in bottom of
|
|
|
+ LEFT VIEW HERT eEx-cBepot 6xx 8x, LERT FRONT VIEW HERT except 6x 8x, LERT RIGHT VIEW
|
|
|
+
|
|
|
+ MoAdIReFl:LHOEW1XCROTNVF/IRGTURRATION RTV RTR UNIT MOUNTING & APPLICATION
|
|
|
+ DrAavawilainblegasTyshpowen:: Unit Dimension
|
|
|
+ Version: MAY18 EA OA EA OA Must be mounted as shown. Airstreams can not
|
|
|
+ be switched.
|
|
|
+ FA
|
|
|
+
|
|
|
+ FA RA
|
|
|
+ RA
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+32 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE1XRT (RTH/RTF) Energy Recovery Ventilator Standaarrdd or EC Motor Option
|
|
|
+
|
|
|
+ 22 5/8" CURB 1X 14 1/4" ABBREVIATIONS
|
|
|
+ Case 44" I.D. EA: Exhaust Air to outside
|
|
|
+ 14 1/2" OA: Outside Air intake
|
|
|
+ 35 1/4" Minimum RA: Room Air to be exhausted
|
|
|
+ Service Area RA FA: Fresh Air to inside
|
|
|
+ RTF: Rooftop Vertical FA Only
|
|
|
+51" Case Door 61 1/8" Minimum RTH: Rooftop Horizontal RA & FA
|
|
|
+ 10 3/4" Swing Service Area INSTALLATION ORIENTATION
|
|
|
+ Unit must be installed in orientation
|
|
|
+ 7 1/2" FA shown.
|
|
|
+ Door NOTE:
|
|
|
+ Swing 47 3/4" O.D. 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ FA (RTF) NEAREST EIGHTH OF AN INCH.
|
|
|
+ 7 1/4" X 6 1/8" 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ Opening
|
|
|
+ 10 1/4" A A 14 1/4" CURB CROSS-SECTION A-A (TYP.)
|
|
|
+ TOP VIEW
|
|
|
+ FA
|
|
|
+
|
|
|
+ 1 1/2" X 1/4" 1 7/8"
|
|
|
+ Neoprene Gasket
|
|
|
+
|
|
|
+ 18 1/4" O.D. 3/4" X 3 1/2" 44"
|
|
|
+ Wooden Nailer Overall
|
|
|
+ TOP VIEW
|
|
|
+ 3" 14"
|
|
|
+ 6 5/8"
|
|
|
+ SECTION A-A
|
|
|
+
|
|
|
+ 81" Overall 2" OA Damper 40 1/4" Overall
|
|
|
+ Typ. Location
|
|
|
+ EA Outlet 45 3/4" 20 1/8"
|
|
|
+ at Back Lift Lugs (Optional) Lift Lugs
|
|
|
+
|
|
|
+ E-Box
|
|
|
+
|
|
|
+EA 21 1/2" OA
|
|
|
+ Wiring
|
|
|
+ Disconnect
|
|
|
+ 41" Switch Pressure Ports
|
|
|
+ Case (4) Typ.
|
|
|
+ 6 5/8"
|
|
|
+ FA RTH RA
|
|
|
+ ONLY
|
|
|
+ 1 1/2"
|
|
|
+
|
|
|
+FA (RTH) 1 1/2" CL 5 5/8" Power In 5" Damper RA RA Damper
|
|
|
+16"X12" Frames Typ. 16" X 12" Location
|
|
|
+Duct Receiving CL 15 1/4" CL 2 1/2" Control In FA Duct Receiving (Optional)
|
|
|
+Flange Wiring (2) 7/8" holes for Flange
|
|
|
+ wiring in bottom of RTF
|
|
|
+ LEFT VIEW ONLY
|
|
|
+
|
|
|
+ E-Box RIGHT VIEW
|
|
|
+
|
|
|
+ HERT except 6x 8x, LERT FRONT VIEW HERTexcept 6x 8x, LERT
|
|
|
+
|
|
|
+MoAdIReFl:LROTWH/CROTFNFIGURATION RTH RTF UNIT MOUNTING & APPLICATION
|
|
|
+DrAavawilainblegasTyshpowen:: Unit Dimension
|
|
|
+Version: MAY18 EA OA EA OA Must be mounted as shown. Airstreams can not
|
|
|
+ be switched.
|
|
|
+ FA RA RA
|
|
|
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 33
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1XRT Energy Recovery Ventilator
|
|
|
+ EC Motor Option
|
|
|
+
|
|
|
+ROOFTOP UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+ Ventilation Type: Options:
|
|
|
+
|
|
|
+ Static plate, heat and humidity transfer Fused disconnect
|
|
|
+
|
|
|
+ Typical Airflow Range: 250-1,100 CFM Integrated programmable controls -
|
|
|
+ AHRI 1060 Certified Core: One L125-G5 enhanced, premium
|
|
|
+
|
|
|
+ Class 1 low leakage motorized isolation dampers -
|
|
|
+
|
|
|
+ Standard Features: OA, RA or both airstreams
|
|
|
+ Non-fused disconnect Qty. 2, Factory mounted filter alarms -
|
|
|
+ 24 VAC transformer/relay package
|
|
|
+ Cross-core differential pressure ports both airstreams
|
|
|
+ Double wall construction
|
|
|
+ Filters: Exterior paint - white, custom colors
|
|
|
+ Total qty. 2, MERV 8: 20" x 20" x 2"
|
|
|
+ Accessories:
|
|
|
+ Unit Dimensions & Weight: Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 81" L x 40 1/4" W x 42 1/4" H Backdraft damper 12"
|
|
|
+ 246-366 lbs., varies by option(s) Potentiometer speed control - remote installed
|
|
|
+ Roof curb - standard 14"
|
|
|
+
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Curb wind clip
|
|
|
+
|
|
|
+ 96" L x 47" W x 50" H Engineered combo curb for Trane RTU
|
|
|
+
|
|
|
+Download specification at: 458 lbs. Engineered combo curb for Carrier RTU
|
|
|
+renewaire.com/specifications
|
|
|
+ Motor(s): Digital time clock - wall mount (TC7D-W),
|
|
|
+EC MOTOR OPTION OPERATING RANGE Qty. 2, 0.5 HP ea., Direct drive EC blower/motor in exterior enclosure (TC7D-E)
|
|
|
+
|
|
|
+ packages Carbon dioxide sensor/control -
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+
|
|
|
+ Electric duct heater - EK series (1–175 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ HE1X-RT ECM (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ 1.75
|
|
|
+
|
|
|
+ HE1XRT EC MOTOR
|
|
|
+
|
|
|
+ Sample Points Depicted in Larger Dots
|
|
|
+
|
|
|
+Airflow External Static Unit Power 1.50 966
|
|
|
+(CFM) Pressure Consumption 1.25 921
|
|
|
+
|
|
|
+ (Inches Water (Watts) 1061
|
|
|
+ Column)
|
|
|
+
|
|
|
+314 0.04 88 External Static Pressure (in. w.g.) 665 898
|
|
|
+
|
|
|
+433 0.07 153 1.00 1074
|
|
|
+ Thermal Performance Ratings G5 2015.2.xlsx HE1X (IOM) 881
|
|
|
+
|
|
|
+627 0.15 321 630
|
|
|
+
|
|
|
+770 0.24 572 1073
|
|
|
+
|
|
|
+ 0.75 397 612 864
|
|
|
+
|
|
|
+901 0.33 838
|
|
|
+
|
|
|
+988 0.41 1053 380 851 1065
|
|
|
+
|
|
|
+ 594
|
|
|
+
|
|
|
+291 0.11 93 0.50 368
|
|
|
+ 354
|
|
|
+ 177 339 582 838 1053
|
|
|
+ 168 321 572
|
|
|
+394 0.20 163 298 564
|
|
|
+
|
|
|
+561 0.42 368 0.25 99 163 828 1041 (Watts)
|
|
|
+ 159
|
|
|
+ 156
|
|
|
+692 0.65 612
|
|
|
+ 91 153
|
|
|
+ 151
|
|
|
+803 0.89 881 87
|
|
|
+ 0.00
|
|
|
+
|
|
|
+857 1.01 1074 250 500 750 1000 1250
|
|
|
+
|
|
|
+Note: Watts is for the entire unit. Airflow (cfm)
|
|
|
+Note: Airflow performance includes effect of clean, standard filter = Actual tested sample points
|
|
|
+supplied with unit.
|
|
|
+ CORE PERFORMANCE
|
|
|
+ Airflow (CFM)
|
|
|
+
|
|
|
+ELECTRICAL DATA Effectiveness (%) 200 400 600 800 1000
|
|
|
+
|
|
|
+ HP Volts HZ Phase Max. 90%
|
|
|
+ 0.5 120 60 Single Overcurrent
|
|
|
+ 0.5 208-230 60 Single FLA Min. Protection 70%
|
|
|
+ per Cir.
|
|
|
+ motor Amps Device 50%
|
|
|
+
|
|
|
+ 8.1 18.2 25
|
|
|
+
|
|
|
+ 4.8 10.8 15
|
|
|
+
|
|
|
+ 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+34 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1XRT (RTV/RTR) Energy Recovery Ventilator SEtCanMdoatrodr oOrpEtiConMotor Option
|
|
|
+
|
|
|
+ 22 5/8" RA Damper ABBREVIATIONS
|
|
|
+ Case Location EA: Exhaust Air to outside
|
|
|
+ (Optional) OA: Outside Air intake
|
|
|
+ RA (Recessed 3/4") CURB 1X RA: Room Air to be exhausted
|
|
|
+ 10 1/4" X 12 1/2" FA: Fresh Air to inside
|
|
|
+ 35 1/4" Minimum 14 1/2" RTV: Rooftop Vertical RA & FA
|
|
|
+ Opening Service Area RTR: Rooftop Vertical RA Only
|
|
|
+ RA INSTALLATION ORIENTATION
|
|
|
+ 51" Case Door 14 1/4" Unit must be installed in orientation
|
|
|
+ 10 3/4" 10 1/4" 10 1/8" Swing 10 1/8" 44" I.D. shown.
|
|
|
+ 61 1/8" Minimum NOTE:
|
|
|
+ Service Area 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ 47 3/4" O.D. DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 7 1/2" A A 14 1/4" CURB CROSS-SECTION A-A (TYP.)
|
|
|
+
|
|
|
+ Door FA
|
|
|
+ Swing
|
|
|
+ FA (RTV) 1 1/2" X 1/4" 1 7/8"
|
|
|
+ 7 1/4" X 6 1/8" Neoprene Gasket
|
|
|
+ Opening
|
|
|
+ 18 1/4" O.D. 3/4" X 3 1/2" 44"
|
|
|
+ TOP VIEW Wooden Nailer Overall
|
|
|
+ TOP VIEW
|
|
|
+ 3" 14"
|
|
|
+
|
|
|
+ SECTION A-A
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 35 EA Outlet 81" Overall 2" 40 1/4" Overall
|
|
|
+ at Back Typ.
|
|
|
+ 45 3/4" 20 1/8"
|
|
|
+ E-Box Lift Lugs OA Lift Lugs
|
|
|
+
|
|
|
+ EA 21 1/2" Disconnect Pressure Ports
|
|
|
+ Wiring Switch (4) Typ.
|
|
|
+ FA (RTR)
|
|
|
+ 16"X12" 41" 6 5/8"
|
|
|
+ Duct Receiving Case
|
|
|
+ Flange
|
|
|
+ FA RTR OA Damper
|
|
|
+ ONLY Location
|
|
|
+
|
|
|
+ (Optional)
|
|
|
+
|
|
|
+ 1 1/2" CL 5 5/8" Power In FA RA
|
|
|
+
|
|
|
+ CL 15 1/4" CL 2 1/2" Control In RTV
|
|
|
+ Wiring (2) 7/8" holes for ONLY
|
|
|
+ wiring in bottom of
|
|
|
+ LEFT VIEW HERT eEx-cBepot 6xx 8x, LERT FRONT VIEW HERT except 6x 8x, LERT RIGHT VIEW
|
|
|
+
|
|
|
+ MoAdIReFl:LHOEW1XCROTNVF/IRGTURRATION RTV RTR UNIT MOUNTING & APPLICATION
|
|
|
+ DrAavawilainblegasTyshpowen:: Unit Dimension
|
|
|
+ Version: MAY18 EA OA EA OA Must be mounted as shown. Airstreams can not
|
|
|
+ be switched.
|
|
|
+ FA
|
|
|
+
|
|
|
+ FA RA
|
|
|
+ RA
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+36 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE1XRT (RTH/RTF) Energy Recovery Ventilator EStCanMdoatrodr oOrpEtiConMotor Option
|
|
|
+
|
|
|
+ 22 5/8" CURB 1X 14 1/4" ABBREVIATIONS
|
|
|
+ Case 44" I.D. EA: Exhaust Air to outside
|
|
|
+ 14 1/2" OA: Outside Air intake
|
|
|
+ 35 1/4" Minimum RA: Room Air to be exhausted
|
|
|
+ Service Area RA FA: Fresh Air to inside
|
|
|
+ RTF: Rooftop Vertical FA Only
|
|
|
+51" Case Door 61 1/8" Minimum RTH: Rooftop Horizontal RA & FA
|
|
|
+ 10 3/4" Swing Service Area INSTALLATION ORIENTATION
|
|
|
+ Unit must be installed in orientation
|
|
|
+ 7 1/2" FA shown.
|
|
|
+ Door NOTE:
|
|
|
+ Swing 47 3/4" O.D. 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ FA (RTF) NEAREST EIGHTH OF AN INCH.
|
|
|
+ 7 1/4" X 6 1/8" 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ Opening
|
|
|
+ 10 1/4" A A 14 1/4" CURB CROSS-SECTION A-A (TYP.)
|
|
|
+ TOP VIEW
|
|
|
+ FA
|
|
|
+
|
|
|
+ 1 1/2" X 1/4" 1 7/8"
|
|
|
+ Neoprene Gasket
|
|
|
+
|
|
|
+ 18 1/4" O.D. 3/4" X 3 1/2" 44"
|
|
|
+ Wooden Nailer Overall
|
|
|
+ TOP VIEW
|
|
|
+ 3" 14"
|
|
|
+ 6 5/8"
|
|
|
+ SECTION A-A
|
|
|
+
|
|
|
+ 81" Overall 2" OA Damper 40 1/4" Overall
|
|
|
+ Typ. Location
|
|
|
+ EA Outlet 45 3/4" 20 1/8"
|
|
|
+ at Back Lift Lugs (Optional) Lift Lugs
|
|
|
+
|
|
|
+ E-Box
|
|
|
+
|
|
|
+EA 21 1/2" OA
|
|
|
+ Wiring
|
|
|
+ Disconnect
|
|
|
+ 41" Switch Pressure Ports
|
|
|
+ Case (4) Typ.
|
|
|
+ 6 5/8"
|
|
|
+ FA RTH RA
|
|
|
+ ONLY
|
|
|
+ 1 1/2"
|
|
|
+
|
|
|
+FA (RTH) 1 1/2" CL 5 5/8" Power In 5" Damper RA RA Damper
|
|
|
+16"X12" Frames Typ. 16" X 12" Location
|
|
|
+Duct Receiving CL 15 1/4" CL 2 1/2" Control In FA Duct Receiving (Optional)
|
|
|
+Flange Wiring (2) 7/8" holes for Flange
|
|
|
+ wiring in bottom of RTF
|
|
|
+ LEFT VIEW ONLY
|
|
|
+
|
|
|
+ E-Box RIGHT VIEW
|
|
|
+
|
|
|
+ HERT except 6x 8x, LERT FRONT VIEW HERTexcept 6x 8x, LERT
|
|
|
+
|
|
|
+MoAdIReFl:LROTWH/CROTFNFIGURATION RTH RTF UNIT MOUNTING & APPLICATION
|
|
|
+DrAavawilainblegasTyshpowen:: Unit Dimension
|
|
|
+Version: MAY18 EA OA EA OA Must be mounted as shown. Airstreams can not
|
|
|
+ be switched.
|
|
|
+ FA RA RA
|
|
|
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 37
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1XRTC Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+ROOFTOP UNIT SPECIFICATIONS
|
|
|
+Direct Connect
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Qty. 2, Variable Speed/ECM - Direct Drive Motors -
|
|
|
+
|
|
|
+ Typical Airflow Range: 500-900 CFM (see HE1XRTC EC Motor submittal) -
|
|
|
+ 0.5 HP 120V/1Ph/60HZ,
|
|
|
+ AHRI 1060 Certified Core: One L125-G5 0.5 HP 208-230V/1Ph/60HZ
|
|
|
+ Independent blower control
|
|
|
+ Standard Features: Fused disconnect
|
|
|
+ Non-fused disconnect Integrated programmable controls -
|
|
|
+ 24 VAC transformer/relay package enhanced, premium
|
|
|
+ Cross-core differential pressure ports Qty. 2, Factory mounted filter alarms -
|
|
|
+ both airstreams
|
|
|
+ Filters: Double wall construction
|
|
|
+ Total qty. 2, MERV 8: 20" x 20" x 2" Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ Unit Dimensions & Weight: Accessories:
|
|
|
+ 73 1/4" L x 40 1/4" W x 50" H Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 269-356 lbs., varies by option(s) Solid state speed control kit - 115V,
|
|
|
+
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): 208-230V (1 required per motor)
|
|
|
+ 96" L x 47" W x 50" H RTC transition kit - for vertical RTU, for horizontal RTU
|
|
|
+ 450 lbs. Rooftop RTC transition paint - white, custom colors
|
|
|
+ Digital time clock - wall mount (TC7D-W),
|
|
|
+ Motor(s):
|
|
|
+ Qty. 2, 0.75 HP ea., Direct drive blower/standard in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ motor packages
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE Note: Electric Duct Heater and Indirect Gas-Fired Duct Furnace are not available on RTC units.
|
|
|
+
|
|
|
+ Tie-In Directly to Rooftop A/C Unit Unit Ducted Independently
|
|
|
+
|
|
|
+Damper Total Watts Static Pressure in Adjacent Air Handler External Static Pressure
|
|
|
+Position 1 Phase 3 Phase (Inches Water Column) (Inches Water Column)
|
|
|
+
|
|
|
+ -0.75 -0.5 -0.25 0.0 +0.25 +0.5 +0.75
|
|
|
+
|
|
|
+ EA FA EA FA EA FA EA FA EA FA EA FA EA FA
|
|
|
+
|
|
|
+100% Open 1,295 1,135 735 1035 865 990 920 945 975 890 920 845 865 790 735 605
|
|
|
+
|
|
|
+65% Open 1,285 1,088 715 995 825 950 880 905 935 855 880 805 825 760 715 605
|
|
|
+
|
|
|
+55% Open 1,275 1,074 715 980 815 935 870 890 925 845 870 795 815 755 715 615
|
|
|
+
|
|
|
+45% Open 1,265 1,030 680 940 790 895 840 850 895 810 840 760 790 720 680 570
|
|
|
+
|
|
|
+35% Open 1,265 951 630 865 745 825 795 785 850 745 795 700 745 665 630 515
|
|
|
+25% Open
|
|
|
+ 1T,h2e65rmal Pe8rf6o6rmance57R0atings7G955 20157.020.xlsx 755 750 715 HE810X0 (IOM6)80 750 640 700 605 570 440
|
|
|
+
|
|
|
+15% Open 1,260 774 510 725 655 685 705 645 750 615 705 580 655 545 510 365
|
|
|
+
|
|
|
+Note: Watts is for the entire unit (2 motors).
|
|
|
+
|
|
|
+Note: Airflow performance includes effect
|
|
|
+of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ Installation Details - Applicable to all RTC units Refer to IOM for more details.
|
|
|
+
|
|
|
+ www.renewaire.com (800) 627- 4499 support@renewaire.com
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ FLA Min. Max. Airflow (CFM)
|
|
|
+ per Cir. Overcurrent
|
|
|
+HP Volts HZ Phase motor Amps Protection Effectiveness (%) 200 400 600 800 1000
|
|
|
+ 90%
|
|
|
+0.75 120 60 Single 9.0 20.3 Device
|
|
|
+0.75 208-230 60 Single 70%
|
|
|
+ 4.5 10.1 25
|
|
|
+
|
|
|
+ 15
|
|
|
+
|
|
|
+0.75 277 60 Single 3.9 8.8 15 50%
|
|
|
+
|
|
|
+0.75 208-230 60 Three 1.7-2.3 5.2 15
|
|
|
+
|
|
|
+0.75 460 60 Three 1.15 2.6 15 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+38 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1XRTC Energy Recovery Ventilator Standaarrdd or EC Motor Option
|
|
|
+
|
|
|
+ 22 1/2" Case ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ 33 3/4" Minimum OA: Outside Air intake
|
|
|
+ Service Area RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ Door INSTALLATION ORIENTATION
|
|
|
+ Swing Unit must be installed in orientation
|
|
|
+ 51" Case shown.
|
|
|
+ 51" Minimum NOTE
|
|
|
+ Service Area 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ Door
|
|
|
+ Swing
|
|
|
+
|
|
|
+ TOP VIEW
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 39 2" Typ. 73 1/4" Overall 40 1/4" Overall
|
|
|
+ 45 3/4"
|
|
|
+ 20 1/8" 2"
|
|
|
+ Lifting Lugs Lifting Lugs 16"
|
|
|
+
|
|
|
+ Control Wiring EA Outlet
|
|
|
+ Inlet 7/8"
|
|
|
+ at Back
|
|
|
+
|
|
|
+ 49 7/8" OverallEA FA 11"
|
|
|
+ 41 1/4" Case RA Typ.
|
|
|
+ Disconnect
|
|
|
+ Switch 3 1/2"
|
|
|
+ 14 1/2" to 17 1/2"
|
|
|
+ OA Height
|
|
|
+ Adjustment
|
|
|
+
|
|
|
+ Power Wiring
|
|
|
+ Inlet 7/8"
|
|
|
+
|
|
|
+ LEFT VIEW Pressure 8 3/8"RIGHT VIEW
|
|
|
+ Ports (4) Typ.
|
|
|
+ AIRFLOW CONFIGURATION UNIT MOUNTING & APPLICATION
|
|
|
+ FRONT VIEW Must be mounted as shown. Airstreams can not
|
|
|
+ MoAvdaileabl:leHasEs1hXowRnTiCn dimension drawing. be switched.
|
|
|
+ Drawing Type: Unit Dimension HE-SERIES
|
|
|
+ Version: MAY18
|
|
|
+SPECIFICATIONS & DIMENSIONS Energy Recovery Ventilator
|
|
|
+ EC Motor Option
|
|
|
+HE 1XRTC
|
|
|
+ SPECIFICATIONS Options:
|
|
|
+ROOFTOP UNIT Fused disconnect
|
|
|
+Direct Connect Ventilation Type: Integrated programmable controls -
|
|
|
+ Static plate, heat and humidity transfer
|
|
|
+Download specification at: enhanced, premium
|
|
|
+renewaire.com/specifications Typical Airflow Range: 500-1,100 CFM Qty. 2, Factory mounted filter alarms -
|
|
|
+
|
|
|
+ AHRI 1060 Certified Core: One L125-G5 both airstreams
|
|
|
+ Double wall construction
|
|
|
+ Standard Features: Exterior paint - white, custom colors
|
|
|
+ Non-fused disconnect
|
|
|
+ 24 VAC transformer/relay package Accessories:
|
|
|
+ Cross-core differential pressure ports Filters - MERV 13, 2" (shipped loose)
|
|
|
+ RTC transition kit - for vertical RTU, for horizontal RTU
|
|
|
+ Filters: Rooftop RTC transition paint - white, custom colors
|
|
|
+ Total qty. 2, MERV 8: 20" x 20" x 2" Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ Unit Dimensions & Weight: in exterior enclosure (TC7D-E)
|
|
|
+ 73 1/4" L x 40 1/4" W x 50" H Carbon dioxide sensor/control -
|
|
|
+ 272-358 lbs., varies by option(s)
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): IAQ sensor - wall mount (IAQ-W),
|
|
|
+ 96" L x 47" W x 50" H
|
|
|
+ 450 lbs. duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+ Motor(s):
|
|
|
+ Qty. 2, 0.5 HP, Direct drive EC blower/ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ motor packages
|
|
|
+
|
|
|
+ Note: Electric Duct Heater and Indirect Gas-Fired Duct Furnace are not available on RTC units.
|
|
|
+
|
|
|
+EC MOTOR OPUTnIOit TNHieEdO1XinP-RtEoTCRAiEArCHTMaInNdGlerRANGE EC MOTOR OPTION OPERATING RANGE
|
|
|
+Tie-In Directly to Rooftop A/C Unit* Unit Ducted IndependenHtlEy1*X-RTC ECM
|
|
|
+
|
|
|
+ Airflow (cfm) Unit Tied Into Separate Ducts
|
|
|
+
|
|
|
+ 500 625 750 875 1000 1125 1250 1.25
|
|
|
+ 0.00 866
|
|
|
+External Static Pressure (in. w.g.) 297 559 907 1040 (Watts)
|
|
|
+ -0.25 333 595 1050
|
|
|
+ 331
|
|
|
+ 1.00
|
|
|
+ External Static Pressure (in. w.g.)
|
|
|
+ 296 562
|
|
|
+
|
|
|
+ -0.50 Thermal Pe45r1formance Rating8s51G5 2015.2.xlsx 0.75 HE1X (IOM) 516
|
|
|
+ 471
|
|
|
+ 1060 806
|
|
|
+ 630 372
|
|
|
+ 654
|
|
|
+ -0.75 0.50 250
|
|
|
+ 755 900
|
|
|
+ 718
|
|
|
+ 444
|
|
|
+
|
|
|
+ -1.00 0.25 131 276 470
|
|
|
+ 277
|
|
|
+ HE1X-RTC EA EC 94 694 890 watts
|
|
|
+
|
|
|
+ -1.25 139 443
|
|
|
+ 140
|
|
|
+ Note: Airflow performance includes effect of clean, standard filter supplied with unit. 89 137 249
|
|
|
+ = Actual tested sample points 89
|
|
|
+ 0.00 500 625 750 875 1000 1125 1250
|
|
|
+ 250 375
|
|
|
+
|
|
|
+ Airflow (cfm)
|
|
|
+
|
|
|
+ * See page 38 for installation details.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ HP Volts HZ Phase FLA Min. Max. Airflow (CFM)
|
|
|
+ 0.5 120 60 Single per Cir. Overcurrent
|
|
|
+ 0.5 208-230 60 Single motor Amps Protection Effectiveness (%) 200 400 600 800 1000
|
|
|
+ 90%
|
|
|
+ 8.1 18.2 Device
|
|
|
+ 70%
|
|
|
+ 4.8 10.8 25
|
|
|
+
|
|
|
+ 15
|
|
|
+
|
|
|
+ 50%
|
|
|
+
|
|
|
+ 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+40 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1XRTC Energy Recovery Ventilator SEtCanMdoatrodr oOrpEtiConMotor Option
|
|
|
+
|
|
|
+ 22 1/2" Case ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ 33 3/4" Minimum OA: Outside Air intake
|
|
|
+ Service Area RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ Door INSTALLATION ORIENTATION
|
|
|
+ Swing Unit must be installed in orientation
|
|
|
+ 51" Case shown.
|
|
|
+ 51" Minimum NOTE
|
|
|
+ Service Area 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ Door
|
|
|
+ Swing
|
|
|
+
|
|
|
+ TOP VIEW
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 41 2" Typ. 73 1/4" Overall 40 1/4" Overall
|
|
|
+ 45 3/4"
|
|
|
+ 20 1/8" 2"
|
|
|
+ Lifting Lugs Lifting Lugs 16"
|
|
|
+
|
|
|
+ Control Wiring EA Outlet
|
|
|
+ Inlet 7/8"
|
|
|
+ at Back
|
|
|
+
|
|
|
+ 49 7/8" OverallEA FA 11"
|
|
|
+ 41 1/4" Case RA Typ.
|
|
|
+ Disconnect
|
|
|
+ Switch 3 1/2"
|
|
|
+ 14 1/2" to 17 1/2"
|
|
|
+ OA Height
|
|
|
+ Adjustment
|
|
|
+
|
|
|
+ Power Wiring
|
|
|
+ Inlet 7/8"
|
|
|
+
|
|
|
+ LEFT VIEW Pressure 8 3/8"RIGHT VIEW
|
|
|
+ Ports (4) Typ.
|
|
|
+ AIRFLOW CONFIGURATION UNIT MOUNTING & APPLICATION
|
|
|
+ FRONT VIEW Must be mounted as shown. Airstreams can not
|
|
|
+ MoAvdaileabl:leHasEs1hXowRnTiCn dimension drawing. be switched.
|
|
|
+ Drawing Type: Unit Dimension HE-SERIES
|
|
|
+ Version: MAY18
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1.5XINH Energy Recovery Ventilator
|
|
|
+ Standarrdd & Bypass Economizer Option
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS Options:
|
|
|
+ Qty. 2, Variable Speed/ECM - Direct drive motors
|
|
|
+Download specification at: Ventilation Type:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer (see HE1.5XINH EC Motor submittal) -
|
|
|
+ 1.0 HP 120V/1Ph/60HZ,
|
|
|
+ Typical Airflow Range: 1.0 HP 208-230V/1Ph/60HZ
|
|
|
+ 375–1,575 CFM Independent blower control
|
|
|
+ Fused disconnect
|
|
|
+ AHRI 1060 Certified Core: Integrated programmable controls -
|
|
|
+ One L62-G5 and one L125-G5 enhanced, premium
|
|
|
+ Bypass economizer damper
|
|
|
+ Standard Features: (see bypass DIM drawing) -
|
|
|
+ Non-fused disconnect dry-bulb temperature controls (standard),
|
|
|
+ 24 VAC transformer/relay package enthalpy controls (option)
|
|
|
+ Cross-core differential pressure ports Class 1 low leakage motorized isolation dampers -
|
|
|
+ FA, EA or both airstreams
|
|
|
+ Filters: Gravity backdraft dampers
|
|
|
+ Total Qty. 4, MERV 8: (2) 14" x 20" x 2" and Qty. 2, Factory mounted filter alarms -
|
|
|
+ both airstreams
|
|
|
+ (2) 16" x 20" x 2" Double wall construction
|
|
|
+ Exterior paint - white, custom colors
|
|
|
+ Unit Dimensions & Weight:
|
|
|
+ 48 3/4" L x" 34 1/2" W x 53 3/4" H Accessories:
|
|
|
+ 337-504 lbs., varies by option(s) Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Backdraft damper - OA or EA
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Digital time clock - wall mount (TC7D-W),
|
|
|
+ 70" L x 47" W x 53" H
|
|
|
+ 571 lbs. in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ Motor(s):
|
|
|
+ Qty. 2, 1.0 HP ea., Direct drive standard motorized wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+ impeller packages
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ Thermal Performance Ratings G5 2015.2.xlsx HE1.5X (IOM)
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+ Motor HP External Static Pressure (Inches Water Column)
|
|
|
+ Phase
|
|
|
+ 0.0 0.25 0.50 0.75 1.00 1.25 1.50
|
|
|
+ 1.0
|
|
|
+ Single Phase 1,575 CFM 1,470 CFM 1,350 CFM 1,225 CFM 1,090 CFM 950 CFM 795 CFM
|
|
|
+ 1,545 Watts 1,525 Watts 1,500 Watts 1,475 Watts 1,435 Watts 1,380 Watts 1,300 Watts
|
|
|
+
|
|
|
+ 1.0 1,675 CFM 1,570 CFM 1,435 CFM 1,280 CFM 1,115 CFM 940 CFM 760 CFM
|
|
|
+ Three Phase 1,410 Watts 1,400 Watts 1,380 Watts 1,340 Watts 1,280 Watts 1,210 Watts 1,135 Watts
|
|
|
+
|
|
|
+Note: Watts is for the entire unit (2 motors).
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+HP V HZ Phase FLA Min. Max. Airflow (CFM)
|
|
|
+ per Cir. Overcurrent
|
|
|
+ motor Amps Protection Effectiveness (%) 300 600 900 1,200 1,500
|
|
|
+ 90%
|
|
|
+ Device
|
|
|
+
|
|
|
+1.0 120 60 Single 6.5 14.6 20
|
|
|
+
|
|
|
+1.0 208-230 60 Single 3.3-3.4 7.7 15 70%
|
|
|
+
|
|
|
+1.0 277 60 Single 2.7 6.1 15 50%
|
|
|
+
|
|
|
+1.0 208-230 60 Three 2.2-2.2 5.0 15
|
|
|
+
|
|
|
+1.0 460 60 Three 1.1 2.5 15 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+42 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1.5XINH Energy Recovery Ventilator Standaarrdd or EC Motor Option
|
|
|
+
|
|
|
+ 42 5/8" Case ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ 34 1/2" Patch Pan OA: Outside Air intake
|
|
|
+ Overall (Opening Used RA: Room Air to be exhausted
|
|
|
+ 32 5/8" for Alternative FA: Fresh Air to inside
|
|
|
+ Case Unit Configurations) INSTALLATION ORIENTATION
|
|
|
+ Typ. Unit may be installed in any
|
|
|
+ orientation.
|
|
|
+ NOTE
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3. MIN. DUCT CLEARANCE
|
|
|
+ FROM DAMPER BLADE WHEN FULLY
|
|
|
+ OPENED TO BE 2". SMACNA RULES
|
|
|
+ APPLY.
|
|
|
+
|
|
|
+ TOP VIEW
|
|
|
+
|
|
|
+ EA Damper 18" X 18" 5" Damper 48 3/4" 20 1/8"Minimum
|
|
|
+ Location Duct Frames Typ. Overall Service Area
|
|
|
+ Receiving (Doors can be
|
|
|
+ (Optional) Flange Typ. Removed from Hinges.)
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 43 32" EA OA 49 3/8"Door
|
|
|
+ 6" Minimum ServiceSwing
|
|
|
+ 52 3/4" Power Wiring
|
|
|
+ Case Inlet 7/8" dia. Area
|
|
|
+ 53 5/8"
|
|
|
+ Control Wiring FA RA OverallDoor32"
|
|
|
+ Inlet 7/8" dia. Swing 6"
|
|
|
+
|
|
|
+ FA Damper 3 1/4" Door-interlocked Pressure 24 1/2"
|
|
|
+ Location Disconnect Switch Ports (4) Typ. 18" X 18"
|
|
|
+ 6 3/8" Typ. (Optional) 1 1/8" Typ. 6 3/8" Typ.
|
|
|
+ Duct
|
|
|
+ Receiving RIGHT VIEW
|
|
|
+ Flange Typ.
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+ LEFT VIEW FRONT VIEW Can be mounted in any orientation. RA/EA airstream
|
|
|
+ can be switched with OA/FA airstream unless
|
|
|
+ DMroAAavIdawRilaeFbinLlle:OgaHsWsTEhyo1Cwp.On5eiNnX:dFIiNmUIGenHnUsiiRtonADdTraiImwOinNeg. nsion certain options are selected. Duct configuration is
|
|
|
+ Version: MAY18 field convertible.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1.5XINH Energy Recovery Ventilator
|
|
|
+ EC Motor Option
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Fused disconnect
|
|
|
+ Typical Airflow Range: 375-1,575 CFM Integrated programmable controls -
|
|
|
+EC MOTOR OPTION OPERATING RANGE AHRI 1060 Certified Core:
|
|
|
+ One L62-G5 and one L125-G5 enhanced, premium
|
|
|
+ Standard Features: Bypass economizer damper
|
|
|
+ Non-fused disconnect
|
|
|
+ 24 VAC transformer/relay package (see bypass DIM drawing) -
|
|
|
+ Cross-core differential pressure ports dry-bulb temperature controls (standard),
|
|
|
+ Filters: enthalpy controls (option)
|
|
|
+ Total qty. 4, MERV 8: (2) 14" x 20" x 2" and Class 1 low leakage motorized isolation dampers -
|
|
|
+ FA, EA or both airstreams
|
|
|
+ (2) 16" x 20" x 2" Gravity backdraft dampers
|
|
|
+ Unit Dimensions & Weight: Qty. 2, Factory mounted filter alarms -
|
|
|
+ 48 3/4" L x 34 1/2" W x 53 3/4" H both airstreams
|
|
|
+ 336-504 lbs., varies by option(s) Double wall construction
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Exterior paint - white, custom colors
|
|
|
+ 70" L x 47" W x 53" H
|
|
|
+ 571 lbs. Accessories:
|
|
|
+ Motor(s): Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Qty. 2, 1.0 HP ea., Direct drive EC motorized Backdraft damper - OA or EA
|
|
|
+ Potentiometer speed control - remote installed
|
|
|
+ impeller packages Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ HE1.5X-IN ECM in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ 1.75
|
|
|
+
|
|
|
+ HE1.5XINH EC MOTOR
|
|
|
+
|
|
|
+ Sample Points Depicted in Larger Dots
|
|
|
+
|
|
|
+ External Static 1.50 965
|
|
|
+ Pressure
|
|
|
+Airflow Unit Power 1006
|
|
|
+(CFM) (Inches Water Consumption 698
|
|
|
+ Column)
|
|
|
+ (Watts) 1.25
|
|
|
+
|
|
|
+630 0.07 189 External Static Pressure (in. w.g.)
|
|
|
+
|
|
|
+807 Therma0l.P12erformance Ratin31g4s G5 2015.2.xlsx 1.00 1017
|
|
|
+
|
|
|
+ HE1.5X (IO72M7 )
|
|
|
+
|
|
|
+1014 0.20 502
|
|
|
+
|
|
|
+1222 0.28 735 475 735 1022
|
|
|
+
|
|
|
+ 0.75
|
|
|
+
|
|
|
+1430 0.39 1015 493 739
|
|
|
+
|
|
|
+ 498 1021
|
|
|
+
|
|
|
+513 0.20 185 0.50 296 739
|
|
|
+ 501
|
|
|
+656 0.33 310 306
|
|
|
+
|
|
|
+ 310 502 1015
|
|
|
+ 502 1006 (Watts)
|
|
|
+825 0.52 498 178 312 500 735
|
|
|
+ 183 730
|
|
|
+ 0.25 1000 1125
|
|
|
+ 185 313
|
|
|
+ 187
|
|
|
+994 0.74 735 188 314
|
|
|
+
|
|
|
+1163 1.01 1017 189 314
|
|
|
+ 190
|
|
|
+
|
|
|
+ 0.00
|
|
|
+
|
|
|
+Note: Watts is for the entire unit. 375 500 625 750 875 1250 1375 1500 1625
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter Airflow (cfm)
|
|
|
+supplied with unit. = Actual tested sample points
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ FLA Min. Max. Airflow (CFM)
|
|
|
+ per Cir. Overcurrent
|
|
|
+HP Volts HZ Phase motor Amps Protection Effectiveness (%) 300 600 900 1,200 1,500
|
|
|
+ 90%
|
|
|
+1.0 120 60 Single 8.0 18.0 Device
|
|
|
+1.0 208-230 60 Single 70%
|
|
|
+ 6.2 14.0 20
|
|
|
+
|
|
|
+ 15
|
|
|
+
|
|
|
+ 50%
|
|
|
+
|
|
|
+ 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+44 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1.5XINH Energy Recovery Ventilator SEtCanMdoatrodr oOrpEtiConMotor Option
|
|
|
+
|
|
|
+ 42 5/8" Case ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ 34 1/2" Patch Pan OA: Outside Air intake
|
|
|
+ Overall (Opening Used RA: Room Air to be exhausted
|
|
|
+ 32 5/8" for Alternative FA: Fresh Air to inside
|
|
|
+ Case Unit Configurations) INSTALLATION ORIENTATION
|
|
|
+ Typ. Unit may be installed in any
|
|
|
+ orientation.
|
|
|
+ NOTE
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3. MIN. DUCT CLEARANCE
|
|
|
+ FROM DAMPER BLADE WHEN FULLY
|
|
|
+ OPENED TO BE 2". SMACNA RULES
|
|
|
+ APPLY.
|
|
|
+
|
|
|
+ TOP VIEW
|
|
|
+
|
|
|
+ EA Damper 18" X 18" 5" Damper 48 3/4" 20 1/8"Minimum
|
|
|
+ Location Duct Frames Typ. Overall Service Area
|
|
|
+ Receiving (Doors can be
|
|
|
+ (Optional) Flange Typ. Removed from Hinges.)
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 45 32" EA OA 49 3/8"Door
|
|
|
+ 6" Minimum ServiceSwing
|
|
|
+ 52 3/4" Power Wiring
|
|
|
+ Case Inlet 7/8" dia. Area
|
|
|
+ 53 5/8"
|
|
|
+ Control Wiring FA RA OverallDoor32"
|
|
|
+ Inlet 7/8" dia. Swing 6"
|
|
|
+
|
|
|
+ FA Damper 3 1/4" Door-interlocked Pressure 24 1/2"
|
|
|
+ Location Disconnect Switch Ports (4) Typ. 18" X 18"
|
|
|
+ 6 3/8" Typ. (Optional) 1 1/8" Typ. 6 3/8" Typ.
|
|
|
+ Duct
|
|
|
+ Receiving RIGHT VIEW
|
|
|
+ Flange Typ.
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+ LEFT VIEW FRONT VIEW Can be mounted in any orientation. RA/EA airstream
|
|
|
+ can be switched with OA/FA airstream unless
|
|
|
+ DMroAAavIdawRilaeFbinLlle:OgaHsWsTEhyo1Cwp.On5eiNnX:dFIiNmUIGenHnUsiiRtonADdTraiImwOinNeg. nsion certain options are selected. Duct configuration is
|
|
|
+ Version: MAY18 field convertible.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1.5XINH Energy Recovery Ventilator
|
|
|
+ Standard with Bypass Economizer
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS Options:
|
|
|
+ Qty. 2, Variable Speed/ECM - Direct drive motors
|
|
|
+Download specification at: Ventilation Type:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer (see HE1.5XINH EC Motor submittal) -
|
|
|
+ 1.0 HP 120V/1Ph/60HZ,
|
|
|
+ Typical Airflow Range: 1.0 HP 208-230V/1Ph/60HZ
|
|
|
+ 375–1,575 CFM Independent blower control
|
|
|
+ Fused disconnect
|
|
|
+ AHRI 1060 Certified Core: Integrated programmable controls -
|
|
|
+ One L62-G5 and one L125-G5 enhanced, premium
|
|
|
+ Bypass economizer damper
|
|
|
+ Standard Features: (see bypass DIM drawing) -
|
|
|
+ Non-fused disconnect dry-bulb temperature controls (standard),
|
|
|
+ 24 VAC transformer/relay package enthalpy controls (option)
|
|
|
+ Cross-core differential pressure ports Class 1 low leakage motorized isolation dampers -
|
|
|
+ FA, EA or both airstreams
|
|
|
+ Filters: Gravity backdraft dampers
|
|
|
+ Total Qty. 4, MERV 8: (2) 14" x 20" x 2" and Qty. 2, Factory mounted filter alarms -
|
|
|
+ both airstreams
|
|
|
+ (2) 16" x 20" x 2" Double wall construction
|
|
|
+ Exterior paint - white, custom colors
|
|
|
+ Unit Dimensions & Weight:
|
|
|
+ 48 3/4" L x 34 1/2" W x 53 3/4" H Accessories:
|
|
|
+ 337-504 lbs., varies by option(s) Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Backdraft damper - OA or EA
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Digital time clock - wall mount (TC7D-W),
|
|
|
+ 70" L x 47" W x 53" H
|
|
|
+ 571 lbs. in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ Motor(s):
|
|
|
+ Qty. 2, 1.0 HP ea., Direct drive standard motorized wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+ impeller packages
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ Thermal Performance Ratings G5 2015.2.xlsx HE1.5X (IOM)
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+ Motor HP External Static Pressure (Inches Water Column)
|
|
|
+ Phase
|
|
|
+ 0.0 0.25 0.50 0.75 1.00 1.25 1.50
|
|
|
+ 1.0
|
|
|
+ Single Phase 1,575 CFM 1,470 CFM 1,350 CFM 1,225 CFM 1,090 CFM 950 CFM 795 CFM
|
|
|
+ 1,545 Watts 1,525 Watts 1,500 Watts 1,475 Watts 1,435 Watts 1,380 Watts 1,300 Watts
|
|
|
+
|
|
|
+ 1.0 1,675 CFM 1,570 CFM 1,435 CFM 1,280 CFM 1,115 CFM 940 CFM 760 CFM
|
|
|
+ Three Phase 1,410 Watts 1,400 Watts 1,380 Watts 1,340 Watts 1,280 Watts 1,210 Watts 1,135 Watts
|
|
|
+
|
|
|
+Note: Watts is for the entire unit (2 motors).
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+HP V HZ Phase FLA Min. Max. Airflow (CFM)
|
|
|
+ per Cir. Overcurrent
|
|
|
+ motor Amps Protection Effectiveness (%) 300 600 900 1,200 1,500
|
|
|
+ 90%
|
|
|
+ Device
|
|
|
+
|
|
|
+1.0 120 60 Single 6.5 14.6 20
|
|
|
+
|
|
|
+1.0 208-230 60 Single 3.3-3.4 7.7 15 70%
|
|
|
+
|
|
|
+1.0 277 60 Single 2.7 6.1 15 50%
|
|
|
+
|
|
|
+1.0 208-230 60 Three 2.2-2.2 5.0 15
|
|
|
+
|
|
|
+1.0 460 60 Three 1.1 2.5 15 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+46 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1.5XINH Energy Recovery Ventilator SWtaitnhdBayrdpawsisthEBcyopnaosms iEzecronOopmtiiozner(Standard & EC Motor)
|
|
|
+
|
|
|
+ 42 5/8" Case 1 1/4" ABBREVIATIONS
|
|
|
+ 13 7/8" EA: Exhaust Air to outside
|
|
|
+ 12" Round Bypass Duct Connection OA: Outside Air intake
|
|
|
+ (Direct Mount to Damper, By Others) RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ BP Bypass 36 3/8" BP: Bypass Air outlet
|
|
|
+ Face Damper Overall INSTALLATION ORIENTATION
|
|
|
+ Damper 31 7/8" Unit may be installed in any
|
|
|
+ RA Case orientation.
|
|
|
+ EA NOTE
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ BYPASS AIRFLOW SCHEMATIC TOP VIEW DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ TOP VIEW 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ (OA/FA Airstream Not Shown) TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3. MIN. DUCT CLEARANCE
|
|
|
+ 16" X 14" Isolation 48 3/4" Overall FROM DAMPER BLADE WHEN FULLY
|
|
|
+ Damper (Optional) OPENED TO BE 2". SMACNA RULES
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 47 6 1/4" Typ. Acts as Face 5" Damper Pressure APPLY.
|
|
|
+ FA Damper Damper for Frames Typ. Ports (4) Typ. 4. UNITS WITH BYPASS WILL REQUIRE
|
|
|
+ Bypass Units ADDITIONAL SPACE FOR THE
|
|
|
+ Location CONNECTION OF THE BYPASS DUCT
|
|
|
+ (Optional) (BY OTHERS).
|
|
|
+ 5. FOR INSTALLATION DETAILS, REFER
|
|
|
+ BP TO I&O MANUAL SUPPLEMENT FOR
|
|
|
+ BYPASS.
|
|
|
+ 20 1/8" Minimum
|
|
|
+ Service Area
|
|
|
+ (Doors can be
|
|
|
+ Removed from Hinges.)
|
|
|
+
|
|
|
+ Door
|
|
|
+ Swing
|
|
|
+
|
|
|
+ Door
|
|
|
+ Swing
|
|
|
+ 52 3/4" Case Power Wiring EA OA
|
|
|
+ 32" Inlet 7/8" dia. FA
|
|
|
+ 6"Control Wiring 12" Bypass
|
|
|
+ 3 1/4"Inlet 7/8" dia.Location
|
|
|
+ 49 3/8" Minimum
|
|
|
+ Service AreaRA
|
|
|
+ 6"
|
|
|
+ 10 5/8"
|
|
|
+ 32"
|
|
|
+ 53 5/8" Overall
|
|
|
+ Plug Location Door-interlocked 1 1/4" Duct 24 1/2" 6 3/8"
|
|
|
+ 12" Bypass Disconnect Switch Receiving Typ.
|
|
|
+ Damper Flange Typ.
|
|
|
+
|
|
|
+ (Not Shown) 18" X 18" FRONT VIEW
|
|
|
+ Duct Receiving
|
|
|
+ LEFT VIEW Flange Typ. RIGHT VIEW
|
|
|
+
|
|
|
+ MAIRoFdLeOlW: HCEO1N.5FXIGINURHA[TBIOyNpass] UNIT MOUNTING & APPLICATION
|
|
|
+ DAvarialabwle ains sghowTnyipn deim:enUsinonitdraDwiinmg. ension
|
|
|
+ Version: MAY18 Can be mounted in any orientation. Airstreams
|
|
|
+ can not be switched.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1.5XINH Energy Recovery Ventilator
|
|
|
+ EC Motoorr wOipthtioBnypass Economizer
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Fused disconnect
|
|
|
+ Typical Airflow Range: 375-1,575 CFM Integrated programmable controls -
|
|
|
+EC MOTOR OPTION OPERATING RANGE AHRI 1060 Certified Core:
|
|
|
+ One L62-G5 and one L125-G5 enhanced, premium
|
|
|
+ Standard Features: Bypass economizer damper
|
|
|
+ Non-fused disconnect
|
|
|
+ 24 VAC transformer/relay package (see bypass DIM drawing) -
|
|
|
+ Cross-core differential pressure ports dry-bulb temperature controls (standard),
|
|
|
+ Filters: enthalpy controls (option)
|
|
|
+ Total qty. 4, MERV 8: (2) 14" x 20" x 2" and Class 1 low leakage motorized isolation dampers -
|
|
|
+ FA, EA or both airstreams
|
|
|
+ (2) 16" x 20" x 2" Gravity backdraft dampers
|
|
|
+ Unit Dimensions & Weight: Qty. 2, Factory mounted filter alarms -
|
|
|
+ 48 3/4" L x 34 1/2" W x 53 3/4" H both airstreams
|
|
|
+ 336-504 lbs., varies by option(s) Double wall construction
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Exterior paint - white, custom colors
|
|
|
+ 70" L x 47" W x 53" H
|
|
|
+ 571 lbs. Accessories:
|
|
|
+ Motor(s): Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Qty. 2, 1.0 HP ea., Direct drive EC motorized Backdraft damper - OA or EA
|
|
|
+ Potentiometer speed control - remote installed
|
|
|
+ impeller packages Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ HE1.5X-IN ECM in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ 1.75
|
|
|
+
|
|
|
+ HE1.5XINH EC MOTOR
|
|
|
+
|
|
|
+ Sample Points Depicted in Larger Dots
|
|
|
+
|
|
|
+ External Static 1.50 965
|
|
|
+ Pressure
|
|
|
+ Airflow Unit Power 1006
|
|
|
+ (CFM) (Inches Water Consumption 698
|
|
|
+ Column)
|
|
|
+ (Watts) 1.25
|
|
|
+
|
|
|
+ 630 0.07 189 External Static Pressure (in. w.g.)
|
|
|
+
|
|
|
+ 807 Therma0l.P12erformance Ratin31g4s G5 2015.2.xlsx 1.00 HE1.5X (IO72M7 ) 1017
|
|
|
+
|
|
|
+ 1014 0.20 502
|
|
|
+
|
|
|
+ 1222 0.28 735 475 735 1022
|
|
|
+
|
|
|
+ 0.75
|
|
|
+
|
|
|
+ 1430 0.39 1015 493 739
|
|
|
+
|
|
|
+ 498 1021
|
|
|
+
|
|
|
+ 513 0.20 185 0.50 296 739
|
|
|
+ 501
|
|
|
+ 656 0.33 310 306
|
|
|
+
|
|
|
+ 310 502 1015
|
|
|
+ 502 1006 (Watts)
|
|
|
+ 825 0.52 498 178 312 500 735
|
|
|
+ 183 730
|
|
|
+ 0.25 1000 1125
|
|
|
+ 185 313
|
|
|
+ 187
|
|
|
+ 994 0.74 735 188 314
|
|
|
+
|
|
|
+ 1163 1.01 1017 189 314
|
|
|
+ 190
|
|
|
+
|
|
|
+ 0.00
|
|
|
+
|
|
|
+Note: Watts is for the entire unit. 375 500 625 750 875 1250 1375 1500 1625
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter Airflow (cfm)
|
|
|
+supplied with unit. = Actual tested sample points
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ FLA Min. Max. Airflow (CFM)
|
|
|
+ per Cir. Overcurrent
|
|
|
+HP Volts HZ Phase motor Amps Protection Effectiveness (%) 300 600 900 1,200 1,500
|
|
|
+ 90%
|
|
|
+ Device
|
|
|
+
|
|
|
+1.0 120 60 Single 8.0 18.0 20
|
|
|
+
|
|
|
+1.0 208-230 60 Single 6.2 14.0 15 70%
|
|
|
+
|
|
|
+ 50%
|
|
|
+
|
|
|
+ 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+48 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1.5XINH Energy Recovery Ventilator EWCithMBotyoprawssithEcBoynpoasmsizEecroOnopmtioizne(rStandard & EC Motor)
|
|
|
+
|
|
|
+ 42 5/8" Case 1 1/4" ABBREVIATIONS
|
|
|
+ 13 7/8" EA: Exhaust Air to outside
|
|
|
+ 12" Round Bypass Duct Connection OA: Outside Air intake
|
|
|
+ (Direct Mount to Damper, By Others) RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ BP Bypass 36 3/8" BP: Bypass Air outlet
|
|
|
+ Face Damper Overall INSTALLATION ORIENTATION
|
|
|
+ Damper 31 7/8" Unit may be installed in any
|
|
|
+ RA Case orientation.
|
|
|
+ EA NOTE
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ BYPASS AIRFLOW SCHEMATIC TOP VIEW DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ TOP VIEW 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ (OA/FA Airstream Not Shown) TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3. MIN. DUCT CLEARANCE
|
|
|
+ 16" X 14" Isolation 48 3/4" Overall FROM DAMPER BLADE WHEN FULLY
|
|
|
+ Damper (Optional) OPENED TO BE 2". SMACNA RULES
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 49 6 1/4" Typ. Acts as Face 5" Damper Pressure APPLY.
|
|
|
+ FA Damper Damper for Frames Typ. Ports (4) Typ. 4. UNITS WITH BYPASS WILL REQUIRE
|
|
|
+ Bypass Units ADDITIONAL SPACE FOR THE
|
|
|
+ Location CONNECTION OF THE BYPASS DUCT
|
|
|
+ (Optional) (BY OTHERS).
|
|
|
+ 5. FOR INSTALLATION DETAILS, REFER
|
|
|
+ BP TO I&O MANUAL SUPPLEMENT FOR
|
|
|
+ BYPASS.
|
|
|
+ 20 1/8" Minimum
|
|
|
+ Service Area
|
|
|
+ (Doors can be
|
|
|
+ Removed from Hinges.)
|
|
|
+
|
|
|
+ Door
|
|
|
+ Swing
|
|
|
+
|
|
|
+ Door
|
|
|
+ Swing
|
|
|
+ 52 3/4" Case Power Wiring EA OA
|
|
|
+ 32" Inlet 7/8" dia. FA
|
|
|
+ 6"Control Wiring 12" Bypass
|
|
|
+ 3 1/4"Inlet 7/8" dia.Location
|
|
|
+ 49 3/8" Minimum
|
|
|
+ Service AreaRA
|
|
|
+ 6"
|
|
|
+ 10 5/8"
|
|
|
+ 32"
|
|
|
+ 53 5/8" Overall
|
|
|
+ Plug Location Door-interlocked 1 1/4" Duct 24 1/2" 6 3/8"
|
|
|
+ 12" Bypass Disconnect Switch Receiving Typ.
|
|
|
+ Damper Flange Typ.
|
|
|
+
|
|
|
+ (Not Shown) 18" X 18" FRONT VIEW
|
|
|
+ Duct Receiving
|
|
|
+ LEFT VIEW Flange Typ. RIGHT VIEW
|
|
|
+
|
|
|
+ MAIRoFdLeOlW: HCEO1N.5FXIGINURHA[TBIOyNpass] UNIT MOUNTING & APPLICATION
|
|
|
+ DAvarialabwle ains sghowTnyipn deim:enUsinonitdraDwiinmg. ension
|
|
|
+ Version: MAY18 Can be mounted in any orientation. Airstreams
|
|
|
+ can not be switched.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1.5XINV Energy Recovery Ventilator
|
|
|
+ Standarrdd & Bypass Economizer Option
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+ HE1.5XINH shown Ventilation Type: Options:
|
|
|
+ Static plate, heat and humidity transfer Qty. 2, Variable Speed/ECM - Direct drive motors
|
|
|
+Download specification at:
|
|
|
+renewaire.com/specifications Typical Airflow Range: 375-1,575 CFM (see HE1.5XINV EC Motor submittal) -
|
|
|
+ 1.0 HP 120V/1Ph/60HZ,
|
|
|
+ AHRI 1060 Certified Core: 1.0 HP 208-230V/1Ph/60HZ
|
|
|
+ One L62-G5 and one L125-G5 Independent blower control
|
|
|
+ Fused disconnect
|
|
|
+ Standard Features: Integrated programmable controls -
|
|
|
+ Non-fused disconnect enhanced, premium
|
|
|
+ 24 VAC transformer/relay package Bypass economizer damper
|
|
|
+ Cross-core differential pressure ports (see bypass DIM drawing) -
|
|
|
+ dry-bulb temperature controls (standard),
|
|
|
+ Filters: enthalpy controls (option)
|
|
|
+ Total qty. 4, MERV 8: (2) 14" x 20" x 2" and Class 1 low leakage motorized isolation dampers -
|
|
|
+ FA, EA or both airstreams
|
|
|
+ (2) 16" x 20" x 2" Gravity backdraft dampers
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+ Unit Dimensions & Weight: both airstreams
|
|
|
+ 59 1/2" L x 34 1/2" W x 46 1/4" H Double wall construction
|
|
|
+ 337-504 lbs., varies by option(s) Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Accessories:
|
|
|
+ 70" L x 47" W x 59" H Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 571 lbs. Backdraft damper - OA or EA
|
|
|
+ Digital time clock - wall mount (TC7D-W),
|
|
|
+ Motor(s):
|
|
|
+ Qty. 2, 1.0 HP ea., Direct drive standard motorized in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ impeller packages
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ Thermal Performance Ratings G5 2015.2.xlsx HE1.5X (IOM)
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+ Motor HP External Static Pressure (Inches Water Column)
|
|
|
+ Phase
|
|
|
+ 0.0 0.25 0.50 0.75 1.00 1.25 1.50
|
|
|
+ 1.0
|
|
|
+Single Phase 1,575 CFM 1,470 CFM 1,350 CFM 1,225 CFM 1,090 CFM 950 CFM 795 CFM
|
|
|
+ 1,545 Watts 1,525 Watts 1,500 Watts 1,475 Watts 1,435 Watts 1,380 Watts 1,300 Watts
|
|
|
+
|
|
|
+ 1.0 1,675 CFM 1,570 CFM 1,435 CFM 1,280 CFM 1,115 CFM 940 CFM 760 CFM
|
|
|
+Three Phase 1,410 Watts 1,400 Watts 1,380 Watts 1,340 Watts 1,280 Watts 1,210 Watts 1,135 Watts
|
|
|
+
|
|
|
+Note: Watts is for the entire unit (2 motors).
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ FLA Min. Max. Airflow (CFM)
|
|
|
+HP Volts HZ Phase per Cir. Overcurrent
|
|
|
+ Amps Protection Effectiveness (%) 300 600 900 1,200 1,500
|
|
|
+ motor 90%
|
|
|
+ 14.6 Device
|
|
|
+1.0 120 60 Single 6.5 7.7 70%
|
|
|
+1.0 208-230 60 Single 3.3-3.4 6.1 20
|
|
|
+1.0 277 60 Single 2.7 5.0 50%
|
|
|
+1.0 208-230 60 Three 2.2-2.2 2.5 15
|
|
|
+1.0 460 60 Three 1.1 30%
|
|
|
+ 15 At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ 15
|
|
|
+
|
|
|
+ 15
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+50 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1.5XINV Energy Recovery Ventilator Standaarrdd or EC Motor Option
|
|
|
+
|
|
|
+ 49 5/8" Case 5" Damper ABBREVIATIONS
|
|
|
+ Frames Typ. EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ 20 1/8" Minimum 32 5/8" RA: Room Air to be exhausted
|
|
|
+ Service Area Case FA: Fresh Air to inside
|
|
|
+ 34 1/2" INSTALLATION ORIENTATION
|
|
|
+ (Doors can be Overall Unit may be installed in any
|
|
|
+ Removed from orientation.
|
|
|
+ Door Door 24 1/2" NOTE
|
|
|
+ Hinges.) Swing Swing 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ Patch Pan NEAREST EIGHTH OF AN INCH.
|
|
|
+ (Opening Used 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ for Alternative 3. MIN. DUCT CLEARANCE
|
|
|
+ Unit Configurations.) FROM DAMPER BLADE WHEN FULLY
|
|
|
+ OPENED TO BE 2". SMACNA RULES
|
|
|
+ Typ. APPLY.
|
|
|
+
|
|
|
+ 49 1/2" Minimum
|
|
|
+ Service Area
|
|
|
+
|
|
|
+ TOP VIEW
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 51 18" X 18" 59 1/2" Overall with 18" X 18"
|
|
|
+ Duct Receiving Damper Frames Duct Receiving
|
|
|
+
|
|
|
+ Flange Typ. Flange Typ.
|
|
|
+
|
|
|
+ RA OA Power Wiring
|
|
|
+ 46 1/4" EA Inlet 7/8"
|
|
|
+ Overall FA 24 5/8"
|
|
|
+ 24 5/8" Door-Interlocked Control Wiring 4 1/4"
|
|
|
+ 3 1/4" Disconnect Switch Inlet 7/8"
|
|
|
+ 45 3/4" 1 1/8" EA Damper 6 3/8"
|
|
|
+ Case Location Typ.
|
|
|
+ 4 1/4" (Optional)
|
|
|
+
|
|
|
+ 6 3/8" FA Damper Pressure
|
|
|
+ Typ. Location Ports (4) Typ.
|
|
|
+ (Optional)
|
|
|
+ FRONT VIEW
|
|
|
+ LEFT VIEW RIGHT VIEW
|
|
|
+
|
|
|
+ DMAAvrIoaaRildaFwbLleeiOnal:sWgsHhoCTEwyO1npi.Nn5edFXimI:GIeNUnUsnViRoniAtdTrDaIwOiimnNg. ension UNIT MOUNTING & APPLICATION
|
|
|
+ Version: MAY18 Can be mounted in any orientation. RA/EA airstream
|
|
|
+ can be switched with OA/FA airstream unless
|
|
|
+ certain options are selected. Duct configuration is
|
|
|
+ field convertible.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1.5XINV Energy Recovery Ventilator
|
|
|
+ EC Motor Option
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+ HE1.5XINH shown Ventilation Type: Options:
|
|
|
+Download specification at: Static plate, heat and humidity transfer Fused disconnect
|
|
|
+renewaire.com/specifications Typical Airflow Range: 375-1,575 CFM Integrated programmable controls -
|
|
|
+ AHRI 1060 Certified Core:
|
|
|
+EC MOTOR OPTION OPERATING RANGE One L62-G5 and one L125-G5 enhanced, premium
|
|
|
+ Standard Features: Bypass economizer damper
|
|
|
+ Non-fused disconnect
|
|
|
+ 24 VAC transformer/relay package (see bypass DIM drawing) -
|
|
|
+ Cross-core differential pressure ports dry-bulb temperature controls (standard),
|
|
|
+ Filters: enthalpy controls (option)
|
|
|
+ Total qty. 4, MERV 8: (2) 14" x 20" x 2" and Class 1 low leakage motorized isolation dampers -
|
|
|
+ FA, EA or both airstreams
|
|
|
+ (2) 16" x 20" x 2" Gravity backdraft dampers
|
|
|
+ Unit Dimensions & Weight: Qty. 2, Factory mounted filter alarms -
|
|
|
+ 59 1/2" L x 34 1/2" W x 46 1/4" H both airstreams
|
|
|
+ 336-504 lbs., varies by option(s) Double wall construction
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Exterior paint - white, custom colors
|
|
|
+ 70" L x 47" W x 59" H
|
|
|
+ 571 lbs. Accessories:
|
|
|
+ Motor(s): Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Qty. 2, 1.0 HP ea., Direct drive EC motorized Backdraft damper - OA or EA
|
|
|
+ Potentiometer speed control - remote installed
|
|
|
+ impeller packages Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ HE1.5X-IN ECM in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ 1.75
|
|
|
+
|
|
|
+ HE1.5XINV EC MOTOR
|
|
|
+
|
|
|
+ Sample Points Depicted in Larger Dots 965
|
|
|
+
|
|
|
+ External Static 1.50 1006
|
|
|
+ Pressure 698
|
|
|
+ Airflow Unit Power 1.25
|
|
|
+ (CFM) (Inches Water Consumption
|
|
|
+ Column)
|
|
|
+ (Watts)
|
|
|
+
|
|
|
+ 630 0.07 189 External Static Pressure (in. w.g.)
|
|
|
+
|
|
|
+ 807 Thermal P0e.1r2formance Rating3s14G5 2015.2.xlsx 1.00 1017
|
|
|
+
|
|
|
+ HE1.5X (IO7M27 )
|
|
|
+
|
|
|
+ 1014 0.20 502 1022
|
|
|
+
|
|
|
+ 475 735
|
|
|
+
|
|
|
+ 1222 0.28 735 0.75
|
|
|
+
|
|
|
+ 1430 0.39 1015 493 739
|
|
|
+
|
|
|
+ 498 1021
|
|
|
+
|
|
|
+ 513 0.20 185 0.50 296 739
|
|
|
+ 501
|
|
|
+ 306
|
|
|
+
|
|
|
+ 656 0.33 310 310 502 1015
|
|
|
+ 502 1006 (Watts)
|
|
|
+ 825 0.52 498 178 312 500 735
|
|
|
+ 183 730
|
|
|
+ 0.25 1000 1125
|
|
|
+ 185 313
|
|
|
+ 187
|
|
|
+ 188 314
|
|
|
+ 994 0.74 735
|
|
|
+ 189 314
|
|
|
+ 190
|
|
|
+ 1163 1.01 1017
|
|
|
+ 0.00
|
|
|
+
|
|
|
+ 375 500 625 750 875 1250 1375 1500 1625
|
|
|
+
|
|
|
+Note: Watts is for the entire unit. Airflow (cfm)
|
|
|
+Note: Airflow performance includes effect of clean, standard filter
|
|
|
+supplied with unit. = Actual tested sample points
|
|
|
+
|
|
|
+ CORE PERFORMANCE
|
|
|
+
|
|
|
+ELECTRICAL DATA
|
|
|
+
|
|
|
+ FLA Min. Max. Airflow (CFM)
|
|
|
+ per Cir. Overcurrent
|
|
|
+HP Volts HZ Phase motor Amps Protection Effectiveness (%) 300 600 900 1,200 1,500
|
|
|
+ 90%
|
|
|
+ Device
|
|
|
+
|
|
|
+1.0 120 60 Single 8.0 18.0 20 70%
|
|
|
+
|
|
|
+1.0 208-230 60 Single 6.2 14.0 15
|
|
|
+
|
|
|
+ 50%
|
|
|
+
|
|
|
+ 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+52 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1.5XINV Energy Recovery Ventilator SEtCanMdoatrodr oOrpEtiConMotor Option
|
|
|
+
|
|
|
+ 49 5/8" Case 5" Damper ABBREVIATIONS
|
|
|
+ Frames Typ. EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ 20 1/8" Minimum 32 5/8" RA: Room Air to be exhausted
|
|
|
+ Service Area Case FA: Fresh Air to inside
|
|
|
+ 34 1/2" INSTALLATION ORIENTATION
|
|
|
+ (Doors can be Overall Unit may be installed in any
|
|
|
+ Removed from orientation.
|
|
|
+ Door Door 24 1/2" NOTE
|
|
|
+ Hinges.) Swing Swing 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ Patch Pan NEAREST EIGHTH OF AN INCH.
|
|
|
+ (Opening Used 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ for Alternative 3. MIN. DUCT CLEARANCE
|
|
|
+ Unit Configurations.) FROM DAMPER BLADE WHEN FULLY
|
|
|
+ OPENED TO BE 2". SMACNA RULES
|
|
|
+ Typ. APPLY.
|
|
|
+
|
|
|
+ 49 1/2" Minimum
|
|
|
+ Service Area
|
|
|
+
|
|
|
+ TOP VIEW
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 53 18" X 18" 59 1/2" Overall with 18" X 18"
|
|
|
+ Duct Receiving Damper Frames Duct Receiving
|
|
|
+
|
|
|
+ Flange Typ. Flange Typ.
|
|
|
+
|
|
|
+ RA OA Power Wiring
|
|
|
+ 46 1/4" EA Inlet 7/8"
|
|
|
+ Overall FA 24 5/8"
|
|
|
+ 24 5/8" Door-Interlocked Control Wiring 4 1/4"
|
|
|
+ 3 1/4" Disconnect Switch Inlet 7/8"
|
|
|
+ 45 3/4" 1 1/8" EA Damper 6 3/8"
|
|
|
+ Case Location Typ.
|
|
|
+ 4 1/4" (Optional)
|
|
|
+
|
|
|
+ 6 3/8" FA Damper Pressure
|
|
|
+ Typ. Location Ports (4) Typ.
|
|
|
+ (Optional)
|
|
|
+ FRONT VIEW
|
|
|
+ LEFT VIEW RIGHT VIEW
|
|
|
+
|
|
|
+ MDAAvrIoaaRildaFwbLleeiOnal:sWgsHhoCTEwyO1npi.Nn5edFXimI:GIeNUnUsnViRoniAtdTrDaIwOiimnNg. ension UNIT MOUNTING & APPLICATION
|
|
|
+ Version: MAY18 Can be mounted in any orientation. RA/EA airstream
|
|
|
+ can be switched with OA/FA airstream unless
|
|
|
+ certain options are selected. Duct configuration is
|
|
|
+ field convertible.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1.5XINV Energy Recovery Ventilator
|
|
|
+ Standard with Bypass Economizer
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+ HE1.5XINH shown Ventilation Type: Options:
|
|
|
+ Static plate, heat and humidity transfer Qty. 2, Variable Speed/ECM - Direct drive motors
|
|
|
+Download specification at:
|
|
|
+renewaire.com/specifications Typical Airflow Range: 375-1,575 CFM (see HE1.5XINV EC Motor submittal) -
|
|
|
+ 1.0 HP 120V/1Ph/60HZ,
|
|
|
+ AHRI 1060 Certified Core: 1.0 HP 208-230V/1Ph/60HZ
|
|
|
+ One L62-G5 and one L125-G5 Independent blower control
|
|
|
+ Fused disconnect
|
|
|
+ Standard Features: Integrated programmable controls -
|
|
|
+ Non-fused disconnect enhanced, premium
|
|
|
+ 24 VAC transformer/relay package Bypass economizer damper
|
|
|
+ Cross-core differential pressure ports (see bypass DIM drawing) -
|
|
|
+ dry-bulb temperature controls (standard),
|
|
|
+ Filters: enthalpy controls (option)
|
|
|
+ Total qty. 4, MERV 8: (2) 14" x 20" x 2" and Class 1 low leakage motorized isolation dampers -
|
|
|
+ FA, EA or both airstreams
|
|
|
+ (2) 16" x 20" x 2" Gravity backdraft dampers
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+ Unit Dimensions & Weight: both airstreams
|
|
|
+ 59 1/2" L x 34 1/2" W x 46 1/4" H Double wall construction
|
|
|
+ 337-504 lbs., varies by option(s) Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Accessories:
|
|
|
+ 70" L x 47" W x 59" H Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 571 lbs. Backdraft damper - OA or EA
|
|
|
+ Digital time clock - wall mount (TC7D-W),
|
|
|
+ Motor(s):
|
|
|
+ Qty. 2, 1.0 HP ea., Direct drive standard motorized in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ impeller packages
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ Thermal Performance Ratings G5 2015.2.xlsx HE1.5X (IOM)
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+ Motor HP External Static Pressure (Inches Water Column)
|
|
|
+ Phase
|
|
|
+ 0.0 0.25 0.50 0.75 1.00 1.25 1.50
|
|
|
+ 1.0
|
|
|
+Single Phase 1,575 CFM 1,470 CFM 1,350 CFM 1,225 CFM 1,090 CFM 950 CFM 795 CFM
|
|
|
+ 1,545 Watts 1,525 Watts 1,500 Watts 1,475 Watts 1,435 Watts 1,380 Watts 1,300 Watts
|
|
|
+
|
|
|
+ 1.0 1,675 CFM 1,570 CFM 1,435 CFM 1,280 CFM 1,115 CFM 940 CFM 760 CFM
|
|
|
+Three Phase 1,410 Watts 1,400 Watts 1,380 Watts 1,340 Watts 1,280 Watts 1,210 Watts 1,135 Watts
|
|
|
+
|
|
|
+Note: Watts is for the entire unit (2 motors).
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ FLA Min. Max. Airflow (CFM)
|
|
|
+HP Volts HZ Phase per Cir. Overcurrent
|
|
|
+ Amps Protection Effectiveness (%) 300 600 900 1,200 1,500
|
|
|
+ motor 90%
|
|
|
+ 14.6 Device
|
|
|
+1.0 120 60 Single 6.5 7.7 70%
|
|
|
+1.0 208-230 60 Single 3.3-3.4 6.1 20
|
|
|
+1.0 277 60 Single 2.7 5.0 50%
|
|
|
+1.0 208-230 60 Three 2.2-2.2 2.5 15
|
|
|
+1.0 460 60 Three 1.1 30%
|
|
|
+ 15 At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ 15
|
|
|
+
|
|
|
+ 15
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+54 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1.5XINV Energy Recovery Ventilator W StaitnhdBayrdpawsisthEBcyopnaosms iEzecronOopmtiiozner(Standard & EC Motor)
|
|
|
+
|
|
|
+ Bypass 12" Round Bypass Duct Connection 20 1/8" Minimum 49 5/8" Case ABBREVIATIONS
|
|
|
+ Damper (Direct Mount to Damper, By Others) Service Area EA: Exhaust Air to outside
|
|
|
+ (Doors can be 11 5/8" OA: Outside Air intake
|
|
|
+ BP Removed from 12" RA: Room Air to be exhausted
|
|
|
+ Hinges.) FA: Fresh Air to inside
|
|
|
+ RA OA 31 7/8" BP: Bypass Air outlet
|
|
|
+ 15 1/4" Case INSTALLATION ORIENTATION
|
|
|
+ FA EA 34 1/2" Unit may be installed in any
|
|
|
+ Overall orientation.
|
|
|
+ NOTE
|
|
|
+ Face Damper Door Door 24 1/2" Patch Pan 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ Swing Swing (Opening Used DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ BYPASS AIRFLOW SCHEMATIC for Alternative NEAREST EIGHTH OF AN INCH.
|
|
|
+ Unit Configurations.) 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ FRONT VIEW Typ. TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3. MIN. DUCT CLEARANCE
|
|
|
+ Plug Location 49 1/2" Minimum FROM DAMPER BLADE WHEN FULLY
|
|
|
+ 12" Bypass Service Area OPENED TO BE 2". SMACNA RULES
|
|
|
+ Damper APPLY.
|
|
|
+ TOP VIEW 4. UNITS WITH BYPASS WILL REQUIRE
|
|
|
+ (Not Shown) ADDITIONAL SPACE FOR THE
|
|
|
+ 59 1/2" Overall CONNECTION OF THE BYPASS DUCT
|
|
|
+ (BY OTHERS).
|
|
|
+ 5. FOR INSTALLATION DETAILS, REFER
|
|
|
+ TO I&O MANUAL SUPPLEMENT FOR
|
|
|
+ BYPASS.
|
|
|
+
|
|
|
+ 6 1/4" 18" X 18" BP2 7/8" 16" X 14" Isolation
|
|
|
+ Typ. Duct Receiving RA Damper (Optional)
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 55 Flange Typ. 6 1/4"
|
|
|
+ Acts as Face Typ.
|
|
|
+ Damper for
|
|
|
+ 48 1/2" Overall OA Bypass Units
|
|
|
+ 45 3/4" Case
|
|
|
+ 4 1/4" FA Power Wiring 4 1/4"
|
|
|
+ 24 5/8" Inlet 7/8" 24 5/8"
|
|
|
+ EA
|
|
|
+
|
|
|
+ Control Wiring
|
|
|
+ Inlet 7/8"
|
|
|
+
|
|
|
+ FA Damper 3 1/4" Pressure 5" Damper 6 1/4"
|
|
|
+ Location Ports (4) Typ. Frames Typ.
|
|
|
+ (Optional) 1 1/4"
|
|
|
+
|
|
|
+ LEFT VIEW Door-Interlocked
|
|
|
+ Disconnect Switch
|
|
|
+ MAoIRdFLeOl:WHEC1O.N5FXIIGNUVRA[BTIyOpNass]
|
|
|
+ DAvraailawbleinasgshoTwynpinedi:meUnsniointdDrawiming.ension FRONT VIEW RIGHT VIEW
|
|
|
+ Version: MAY18
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+
|
|
|
+ Can be mounted in any orientation. Airstreams
|
|
|
+ can not be switched.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1.5XINV Energy Recovery Ventilator
|
|
|
+ EC Motoorr wOipthtioBnypass Economizer
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+ HE1.5XINH shown Ventilation Type: Options:
|
|
|
+Download specification at: Static plate, heat and humidity transfer Fused disconnect
|
|
|
+renewaire.com/specifications Typical Airflow Range: 375-1,575 CFM Integrated programmable controls -
|
|
|
+ AHRI 1060 Certified Core:
|
|
|
+EC MOTOR OPTION OPERATING RANGE One L62-G5 and one L125-G5 enhanced, premium
|
|
|
+ Standard Features: Bypass economizer damper
|
|
|
+ Non-fused disconnect
|
|
|
+ 24 VAC transformer/relay package (see bypass DIM drawing) -
|
|
|
+ Cross-core differential pressure ports dry-bulb temperature controls (standard),
|
|
|
+ Filters: enthalpy controls (option)
|
|
|
+ Total qty. 4, MERV 8: (2) 14" x 20" x 2" and Class 1 low leakage motorized isolation dampers -
|
|
|
+ FA, EA or both airstreams
|
|
|
+ (2) 16" x 20" x 2" Gravity backdraft dampers
|
|
|
+ Unit Dimensions & Weight: Qty. 2, Factory mounted filter alarms -
|
|
|
+ 59 1/2" L x 34 1/2" W x 46 1/4" H both airstreams
|
|
|
+ 336-504 lbs., varies by option(s) Double wall construction
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Exterior paint - white, custom colors
|
|
|
+ 70" L x 47" W x 59" H
|
|
|
+ 571 lbs. Accessories:
|
|
|
+ Motor(s): Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Qty. 2, 1.0 HP ea., Direct drive EC motorized Backdraft damper - OA or EA
|
|
|
+ Potentiometer speed control - remote installed
|
|
|
+ impeller packages Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ HE1.5X-IN ECM in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ 1.75
|
|
|
+
|
|
|
+ HE1.5XINV EC MOTOR
|
|
|
+
|
|
|
+ Sample Points Depicted in Larger Dots 965
|
|
|
+
|
|
|
+ External Static 1.50 1006
|
|
|
+ Pressure 698
|
|
|
+ Airflow Unit Power 1.25
|
|
|
+ (CFM) (Inches Water Consumption
|
|
|
+ Column)
|
|
|
+ (Watts)
|
|
|
+
|
|
|
+ 630 0.07 189 External Static Pressure (in. w.g.)
|
|
|
+
|
|
|
+ 807 Thermal P0e.1r2formance Rating3s14G5 2015.2.xlsx 1.00 1017
|
|
|
+
|
|
|
+ HE1.5X (IO7M27 )
|
|
|
+
|
|
|
+ 1014 0.20 502 1022
|
|
|
+
|
|
|
+ 475 735
|
|
|
+
|
|
|
+ 1222 0.28 735 0.75
|
|
|
+
|
|
|
+ 1430 0.39 1015 493 739
|
|
|
+
|
|
|
+ 498 1021
|
|
|
+
|
|
|
+ 513 0.20 185 0.50 296 739
|
|
|
+ 501
|
|
|
+ 306
|
|
|
+
|
|
|
+ 656 0.33 310 310 502 1015
|
|
|
+ 502 1006 (Watts)
|
|
|
+ 825 0.52 498 178 312 500 735
|
|
|
+ 183 730
|
|
|
+ 0.25 1000 1125
|
|
|
+ 185 313
|
|
|
+ 187
|
|
|
+ 188 314
|
|
|
+ 994 0.74 735
|
|
|
+ 189 314
|
|
|
+ 190
|
|
|
+ 1163 1.01 1017
|
|
|
+ 0.00
|
|
|
+
|
|
|
+ 375 500 625 750 875 1250 1375 1500 1625
|
|
|
+
|
|
|
+Note: Watts is for the entire unit. Airflow (cfm)
|
|
|
+Note: Airflow performance includes effect of clean, standard filter
|
|
|
+supplied with unit. = Actual tested sample points
|
|
|
+
|
|
|
+ CORE PERFORMANCE
|
|
|
+
|
|
|
+ELECTRICAL DATA
|
|
|
+
|
|
|
+ FLA Min. Max. Airflow (CFM)
|
|
|
+ per Cir. Overcurrent
|
|
|
+HP Volts HZ Phase motor Amps Protection Effectiveness (%) 300 600 900 1,200 1,500
|
|
|
+ 90%
|
|
|
+ Device
|
|
|
+
|
|
|
+1.0 120 60 Single 8.0 18.0 20 70%
|
|
|
+
|
|
|
+1.0 208-230 60 Single 6.2 14.0 15
|
|
|
+
|
|
|
+ 50%
|
|
|
+
|
|
|
+ 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+56 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE1.5XINV Energy Recovery Ventilator EWCithMBotyoprawssithEcBoynpoasmsizEecroOnopmtioizne(rStandard & EC Motor)
|
|
|
+
|
|
|
+ Bypass 12" Round Bypass Duct Connection 20 1/8" Minimum 49 5/8" Case ABBREVIATIONS
|
|
|
+ Damper (Direct Mount to Damper, By Others) Service Area EA: Exhaust Air to outside
|
|
|
+ (Doors can be 11 5/8" OA: Outside Air intake
|
|
|
+ BP Removed from 12" RA: Room Air to be exhausted
|
|
|
+ Hinges.) FA: Fresh Air to inside
|
|
|
+ RA OA 31 7/8" BP: Bypass Air outlet
|
|
|
+ 15 1/4" Case INSTALLATION ORIENTATION
|
|
|
+ FA EA 34 1/2" Unit may be installed in any
|
|
|
+ Overall orientation.
|
|
|
+ NOTE
|
|
|
+ Face Damper Door Door 24 1/2" Patch Pan 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ Swing Swing (Opening Used DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ BYPASS AIRFLOW SCHEMATIC for Alternative NEAREST EIGHTH OF AN INCH.
|
|
|
+ Unit Configurations.) 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ FRONT VIEW Typ. TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3. MIN. DUCT CLEARANCE
|
|
|
+ Plug Location 49 1/2" Minimum FROM DAMPER BLADE WHEN FULLY
|
|
|
+ 12" Bypass Service Area OPENED TO BE 2". SMACNA RULES
|
|
|
+ Damper APPLY.
|
|
|
+ TOP VIEW 4. UNITS WITH BYPASS WILL REQUIRE
|
|
|
+ (Not Shown) ADDITIONAL SPACE FOR THE
|
|
|
+ 59 1/2" Overall CONNECTION OF THE BYPASS DUCT
|
|
|
+ (BY OTHERS).
|
|
|
+ 5. FOR INSTALLATION DETAILS, REFER
|
|
|
+ TO I&O MANUAL SUPPLEMENT FOR
|
|
|
+ BYPASS.
|
|
|
+
|
|
|
+ 6 1/4" 18" X 18" BP2 7/8" 16" X 14" Isolation
|
|
|
+ Typ. Duct Receiving RA Damper (Optional)
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 57 Flange Typ. 6 1/4"
|
|
|
+ Acts as Face Typ.
|
|
|
+ Damper for
|
|
|
+ 48 1/2" Overall OA Bypass Units
|
|
|
+ 45 3/4" Case
|
|
|
+ 4 1/4" FA Power Wiring 4 1/4"
|
|
|
+ 24 5/8" Inlet 7/8" 24 5/8"
|
|
|
+ EA
|
|
|
+
|
|
|
+ Control Wiring
|
|
|
+ Inlet 7/8"
|
|
|
+
|
|
|
+ FA Damper 3 1/4" Pressure 5" Damper 6 1/4"
|
|
|
+ Location Ports (4) Typ. Frames Typ.
|
|
|
+ (Optional) 1 1/4"
|
|
|
+
|
|
|
+ LEFT VIEW Door-Interlocked
|
|
|
+ Disconnect Switch
|
|
|
+ MAoIRdFLeOl:WHEC1O.N5FXIIGNUVRA[BTIyOpNass]
|
|
|
+ DAvraailawbleinasgshoTwynpinedi:meUnsniointdDrawiming.ension FRONT VIEW RIGHT VIEW
|
|
|
+ Version: MAY18
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+
|
|
|
+ Can be mounted in any orientation. Airstreams
|
|
|
+ can not be switched.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1.5XRT Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+ROOFTOP UNIT SPECIFICATIONS Options:
|
|
|
+ Ventilation Type: Qty. 2, Variable Speed/ECM - Direct drive motors
|
|
|
+Download specification at: Static plate, heat and humidity transfer
|
|
|
+renewaire.com/specifications Typical Airflow Range: 375-1,575 CFM (see HE1.5XRT EC Motor submittal) -
|
|
|
+ AHRI 1060 Certified Core: 1.0 HP 120V/1Ph/60HZ,
|
|
|
+ One L62-G5 and one L125-G5 1.0 HP 208-230V/1Ph/60HZ
|
|
|
+ Standard Features: Independent blower control
|
|
|
+ Non-fused disconnect Onboard variable frequency drives (VFDs) -
|
|
|
+ 24 VAC transformer/relay package one or both airstreams
|
|
|
+ Cross-core differential pressure ports Fused disconnect
|
|
|
+ Filters: Integrated programmable controls -
|
|
|
+ Total qty. 4, MERV 8: (2) 14" x 20" x 2" and enhanced, premium
|
|
|
+ Class 1 low leakage motorized isolation dampers -
|
|
|
+ (2) 16" x 20" x 2" FA, EA or both airstreams
|
|
|
+ Unit Dimensions & Weight: Gravity backdraft dampers
|
|
|
+ 86" L x 33 1/4" W x 56 3/4" H Qty. 2, Factory mounted filter alarms -
|
|
|
+ 387-548 lbs., varies by option(s) both airstreams
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Double wall construction
|
|
|
+ 70" L x 47" W x 83" H Exterior paint - white, custom colors
|
|
|
+ 615 lbs.
|
|
|
+ Motor(s): Accessories:
|
|
|
+ Qty. 2, 1.0 HP ea., Direct drive standard motorized Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Backdraft damper - OA or EA
|
|
|
+ impeller packages Roof curb - standard 14"
|
|
|
+ Curb wind clip
|
|
|
+ Thermal Performance Ratings G5 2015.2.xlsx Engineered combo curb for Carrier RTU
|
|
|
+ Engineered combo curb for Trane RTU
|
|
|
+ Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), insHtaEl1le.d5Xdo(wIOnMstr)eam of any fans
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+ Motor HP External Static Pressure (Inches Water Column)
|
|
|
+ Phase
|
|
|
+ 0.0 0.25 0.50 0.75 1.00 1.25 1.50
|
|
|
+ 1.0
|
|
|
+ Single Phase 1,535 CFM 1390 CFM 1255 CFM 1120 CFM 970 CFM 815 CFM 640 CFM
|
|
|
+ 1,540 Watts 1515 Watts 1485 Watts 1445 Watts 1395 Watts 1310 Watts 1195 Watts
|
|
|
+
|
|
|
+ 1.0 1,630 CFM 1485 CFM 1335 CFM 1170 CFM 995 CFM 810 CFM 615 CFM
|
|
|
+ Three Phase 1,440 Watts 1435 Watts 1415 Watts 1375 Watts 1325 Watts 1260 Watts 1180 Watts
|
|
|
+
|
|
|
+Note: Watts is for the entire unit (2 motors).
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+ Min. Max. Max. Effectiveness (%) 300 600 900 1,200 1,500
|
|
|
+ Cir. Overcurrent Overcurrent 90%
|
|
|
+HP Volts HZ Phase FLA Amps Protection FLA Min. Cir. Protection
|
|
|
+ per motor per motor Amps
|
|
|
+ Device Device
|
|
|
+ 70%
|
|
|
+
|
|
|
+1.0 120 60 Single 6.5 14.6 20
|
|
|
+
|
|
|
+1.0 208-230 60 Single 3.3-3.4 7.7 15 50%
|
|
|
+
|
|
|
+1.0 277 60 Single 2.7 6.1 15 30%
|
|
|
+
|
|
|
+1.0 208-230 60 Three 2.2-2.2 5.0 15 2.2 - 2.2 5.4 15 At AHRI 1060 standard conditions.
|
|
|
+ See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+1.0 460 60 Three 1.1 2.5 15 1.1 2.8 15
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+58 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE1.5XRT (RTV/RTR) Energy Recovery Ventilator Standaarrdd or EC Motor Option
|
|
|
+
|
|
|
+ CURB 1.5X 28 1/4" 45 3/4" Case ABBREVIATIONS
|
|
|
+ 2 1/8" O.D. 32 1/4" RA EA: Exhaust Air to outside
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 594 1/4" 1 1/8" Opening OA: Outside Air intake
|
|
|
+17 1/8" I.D. 11 1/8" 14" x 16" RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ 17 1/8" I.D. RTV: Rooftop Vertical RA & FA
|
|
|
+ RTR: Rooftop Vertical RA Only
|
|
|
+24 1/2" A A FA (RTV) 15 3/8" INSTALLATION ORIENTATION
|
|
|
+ I.D. FA RA 14" x 16" 32 5/8" Unit must be installed in orientation
|
|
|
+ Opening Case shown.
|
|
|
+ NOTE:
|
|
|
+ 1 7/8" 38 1/2" I.D. 10 1/8" Door Door 24 3/4" 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ 42 1/4" O.D. FA (RTV) Swing Swing Minimum DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ Damper Location Service NEAREST EIGHTH OF AN INCH.
|
|
|
+ TOP VIEW (Optional) 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ Area TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+CURB CROSS-SECTION A-A (TYP.) 55 5/8" Minimum 33 1/4"
|
|
|
+ Service Area Overall
|
|
|
+ 1 1/2" X 1/4" 1 7/8" 29 3/4"
|
|
|
+ Neoprene Gasket TOP VIEW Lift Lugs
|
|
|
+
|
|
|
+ 3/4" X 3 1/2" 86" Overall RIGHT VIEW
|
|
|
+ Wooden Nailer 42 7/8" Lift Lugs
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+ 3" Must be mounted as shown. Airstreams can not be
|
|
|
+ switched. Duct configuration is field convertible.
|
|
|
+ SECTION A-A
|
|
|
+
|
|
|
+56 3/4" EA Damper 5" Damper OA
|
|
|
+ Overall Location Frames Typ. Pressure
|
|
|
+ (Optional) Ports (4) Typ.
|
|
|
+ 54" EA
|
|
|
+ Case FA (RTR)
|
|
|
+ 18" X 18" E-Box
|
|
|
+ Duct Receiving Disconnect
|
|
|
+ Flange
|
|
|
+ Switch
|
|
|
+
|
|
|
+ 22 1/8" FA RTR 1 7/8"
|
|
|
+ Wiring ONLY
|
|
|
+
|
|
|
+ 3 5/8" CL 5 5/8" Power In FA
|
|
|
+
|
|
|
+CL 26 1/8" LEFT VIEW 5 7/8" FA (RTR) CL 2 1/2" Control In RTV RA
|
|
|
+ Wiring Damper Location (2) 7/8" holes for ONLY
|
|
|
+
|
|
|
+ (Optional) wiring in bottom of
|
|
|
+
|
|
|
+ HERT except 6x 8x, LEER-TBox HERT except 6x 8x, LERT
|
|
|
+
|
|
|
+ FRONT VIEW
|
|
|
+
|
|
|
+MoAdIReFlL: OHW E1C.5OXNRFTIVG/URRTARTION RTV RTR
|
|
|
+DraAvwailainblegasTsyhpowen:: Unit Dimension
|
|
|
+ EA OA EA OA
|
|
|
+
|
|
|
+Version: MAY18 FA
|
|
|
+
|
|
|
+ FA RA
|
|
|
+ RA
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+ 2 1/8"
|
|
|
+60 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE1.5XRT (RTH/RTF) Energy Recovery Ventilator Standaarrdd or EC Motor Option
|
|
|
+
|
|
|
+ CURB 1.5X 28 1/4" 45 3/4" Case ABBREVIATIONS
|
|
|
+ O.D. 11 1/8" EA: Exhaust Air to outside
|
|
|
+ 4 1/4" 1 1/8" OA: Outside Air intake
|
|
|
+17 1/8" I.D. 17 1/8" I.D. 15 3/8" RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+24 1/2" A A FA (RTF) 32 5/8" RTF: Rooftop Vertical FA Only
|
|
|
+ I.D. FA RA 14" x 16" Case RTH: Rooftop Horizontal RA & FA
|
|
|
+ Opening INSTALLATION ORIENTATION
|
|
|
+ Unit must be installed in orientation
|
|
|
+ 1 7/8" 38 1/2" I.D. 10 1/8" Door Door 24 3/4" shown.
|
|
|
+ 42 1/4" O.D. FA (RTF) Swing Swing Minimum NOTE:
|
|
|
+ Damper Location Service 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ (Optional) DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ Area NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ TOP VIEW
|
|
|
+
|
|
|
+CURB CROSS-SECTION A-A (TYP.) 55 5/8" Minimum
|
|
|
+ Service Area
|
|
|
+ 1 1/2" X 1/4" 1 7/8"
|
|
|
+ Neoprene Gasket TOP VIEW
|
|
|
+
|
|
|
+ 3/4" X 3 1/2"
|
|
|
+ Wooden Nailer
|
|
|
+
|
|
|
+ 3" 86" Overall 33 1/4"
|
|
|
+ 42 7/8" Lift Lugs
|
|
|
+ SECTION A-A Overall
|
|
|
+ 29 3/4"
|
|
|
+ EA Damper
|
|
|
+ Location Lift Lugs
|
|
|
+ (Optional)
|
|
|
+56 3/4" EA OA RA
|
|
|
+ Overall FA (RTH) 18" X 18"
|
|
|
+ 18" X 18" E-Box RA Duct Receiving
|
|
|
+ 54" Duct Receiving Disconnect Flange
|
|
|
+ Case Flange Pressure
|
|
|
+ Switch Ports (4) Typ.
|
|
|
+
|
|
|
+ 22 1/8" FA RTH 1 7/8"
|
|
|
+ Wiring ONLY 6"
|
|
|
+
|
|
|
+ 3 5/8" CL 5 5/8" Power In FA
|
|
|
+
|
|
|
+CL 26 1/8" LEFT VIEW 5 7/8" FA (RTH) CL 2 1/2" Control In RTF 6 3/8"
|
|
|
+ Wiring
|
|
|
+ Damper Location (2) 7/8" holes for ONLY RIGHT VIEW
|
|
|
+
|
|
|
+ (Optional) wiring in bottom of UNIT MOUNTING & APPLICATION
|
|
|
+ Must be mounted as shown. Airstreams can not be
|
|
|
+ HERT except 6x 8x, LEER-TBox HERTexcept 6x 8x, LERT switched. Duct configuration is field convertible.
|
|
|
+
|
|
|
+ FRONT VIEW
|
|
|
+
|
|
|
+DMroaAAvdIwaRielaFinblL:legOHasW TEsy1hpoC.w5eOnX::NRUFTnIHGit/UDRRTiAmFTeIOnNsion RTH RTF
|
|
|
+ EA
|
|
|
+ EA OA OA
|
|
|
+ FA RA RA
|
|
|
+
|
|
|
+Version: MAY18 FA
|
|
|
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 61
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 1.5XRT Energy Recovery Ventilator
|
|
|
+ EC Motor Option
|
|
|
+
|
|
|
+ROOFTOP UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Fused disconnect
|
|
|
+ Typical Airflow Range: 375-1,525 CFM Integrated programmable controls -
|
|
|
+EC MOTOR OPTION OPERATING RANGE AHRI 1060 Certified Core:
|
|
|
+ One L62-G5 and one L125-G5 enhanced, premium
|
|
|
+ Standard Features: Class 1 low leakage motorized isolation dampers -
|
|
|
+ Non-fused disconnect
|
|
|
+ 24 VAC transformer/relay package FA, EA or both airstreams
|
|
|
+ Cross-core differential pressure ports Gravity backdraft dampers
|
|
|
+ Filters: Qty. 2, Factory mounted filter alarms -
|
|
|
+ Total qty. 4, MERV 8: (2) 14" x 20" x 2" and
|
|
|
+ both airstreams
|
|
|
+ (2) 16" x 20" x 2" Double wall construction
|
|
|
+ Unit Dimensions & Weight: Exterior paint - white, custom colors
|
|
|
+ 86" L x 33 1/4" W x 56 3/4" H
|
|
|
+ 386-548 lbs., varies by option(s) Accessories:
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 70" L x 47" W x 83" H Backdraft damper - OA or EA
|
|
|
+ 615 lbs. Potentiometer speed control - remote installed
|
|
|
+ Motor(s): Roof curb - standard 14"
|
|
|
+ Qty. 2, 1.0 HP ea., Direct drive EC motorized Curb wind clip
|
|
|
+ Engineered combo curb for Carrier RTU
|
|
|
+ impeller packages Engineered combo curb for Trane RTU
|
|
|
+ Digital time clock - wall mount (TC7D-W),
|
|
|
+ HE1.5X-RT ECM
|
|
|
+ in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ 1.75
|
|
|
+
|
|
|
+ HE1.5XRT EC MOTOR
|
|
|
+
|
|
|
+ Sample Points Depicted in Larger Dots 1.50 907
|
|
|
+
|
|
|
+Airflow External Static Unit Power 1.25 973
|
|
|
+(CFM) Pressure Consumption 658
|
|
|
+
|
|
|
+ (Inches Water (Watts) HE1.5X (IOM) 1000
|
|
|
+ Column)
|
|
|
+ External Static Pressure (in. w.g.) 703
|
|
|
+593 0.07 188 G5
|
|
|
+ Thermal Performance Ratings 2015.2.xlsx
|
|
|
+ 0.12 313 1.00
|
|
|
+760
|
|
|
+
|
|
|
+955 0.20 502 451 722 1015
|
|
|
+
|
|
|
+1151 0.29 739 0.75
|
|
|
+
|
|
|
+ 478 733
|
|
|
+
|
|
|
+1347 0.39 1021 489 1022
|
|
|
+
|
|
|
+453 0.20 182 0.50 283 497 738
|
|
|
+ 298
|
|
|
+
|
|
|
+ 304 501 739 1021
|
|
|
+ 735 1015 (Watts)
|
|
|
+577 0.33 304 179 309
|
|
|
+
|
|
|
+725 0.51 489 0.25 182 312 502
|
|
|
+ 185 313 501
|
|
|
+ 187
|
|
|
+ 188
|
|
|
+874 0.74 722 189 314
|
|
|
+
|
|
|
+1026 1.01 1000 0.00
|
|
|
+
|
|
|
+ 375 500 625 750 875 1000 1125 1250 1375 1500 1625
|
|
|
+
|
|
|
+Note: Watts is for the entire unit. Airflow (cfm)
|
|
|
+Note: Airflow performance includes effect of clean, standard filter
|
|
|
+supplied with unit. = Actual tested sample points
|
|
|
+
|
|
|
+ CORE PERFORMANCE
|
|
|
+
|
|
|
+ELECTRICAL DATA Airflow (CFM)
|
|
|
+
|
|
|
+ HP Volts HZ Phase FLA Min. Max. Effectiveness (%) 300 600 900 1,200 1,500
|
|
|
+ 1.0 120 60 Single per Cir. Overcurrent 90%
|
|
|
+ 1.0 208-230 60 Single motor Amps Protection
|
|
|
+ 70%
|
|
|
+ 8.0 18.0 Device
|
|
|
+ 50%
|
|
|
+ 6.2 14.0 20
|
|
|
+
|
|
|
+ 15
|
|
|
+
|
|
|
+ 30%
|
|
|
+ At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+62 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE1.5XRT (RTV/RTR) Energy Recovery Ventilator SEtCanMdoatrodr oOrpEtiConMotor Option
|
|
|
+
|
|
|
+ CURB 1.5X 28 1/4" 45 3/4" Case ABBREVIATIONS
|
|
|
+ 2 1/8" O.D. 32 1/4" RA EA: Exhaust Air to outside
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 634 1/4" 1 1/8" Opening OA: Outside Air intake
|
|
|
+17 1/8" I.D. 11 1/8" 14" x 16" RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ 17 1/8" I.D. RTV: Rooftop Vertical RA & FA
|
|
|
+ RTR: Rooftop Vertical RA Only
|
|
|
+24 1/2" A A FA (RTV) 15 3/8" INSTALLATION ORIENTATION
|
|
|
+ I.D. FA RA 14" x 16" 32 5/8" Unit must be installed in orientation
|
|
|
+ Opening Case shown.
|
|
|
+ NOTE:
|
|
|
+ 1 7/8" 38 1/2" I.D. 10 1/8" Door Door 24 3/4" 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ 42 1/4" O.D. FA (RTV) Swing Swing Minimum DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ Damper Location Service NEAREST EIGHTH OF AN INCH.
|
|
|
+ TOP VIEW (Optional) 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ Area TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+CURB CROSS-SECTION A-A (TYP.) 55 5/8" Minimum 33 1/4"
|
|
|
+ Service Area Overall
|
|
|
+ 1 1/2" X 1/4" 1 7/8" 29 3/4"
|
|
|
+ Neoprene Gasket TOP VIEW Lift Lugs
|
|
|
+
|
|
|
+ 3/4" X 3 1/2" 86" Overall RIGHT VIEW
|
|
|
+ Wooden Nailer 42 7/8" Lift Lugs
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+ 3" Must be mounted as shown. Airstreams can not be
|
|
|
+ switched. Duct configuration is field convertible.
|
|
|
+ SECTION A-A
|
|
|
+
|
|
|
+56 3/4" EA Damper 5" Damper OA
|
|
|
+ Overall Location Frames Typ. Pressure
|
|
|
+ (Optional) Ports (4) Typ.
|
|
|
+ 54" EA
|
|
|
+ Case FA (RTR)
|
|
|
+ 18" X 18" E-Box
|
|
|
+ Duct Receiving Disconnect
|
|
|
+ Flange
|
|
|
+ Switch
|
|
|
+
|
|
|
+ 22 1/8" FA RTR 1 7/8"
|
|
|
+ Wiring ONLY
|
|
|
+
|
|
|
+ 3 5/8" CL 5 5/8" Power In FA
|
|
|
+
|
|
|
+CL 26 1/8" LEFT VIEW 5 7/8" FA (RTR) CL 2 1/2" Control In RTV RA
|
|
|
+ Wiring Damper Location (2) 7/8" holes for ONLY
|
|
|
+
|
|
|
+ (Optional) wiring in bottom of
|
|
|
+
|
|
|
+ HERT except 6x 8x, LEER-TBox HERT except 6x 8x, LERT
|
|
|
+
|
|
|
+ FRONT VIEW
|
|
|
+
|
|
|
+MoAdIReFlL: OHW E1C.5OXNRFTIVG/URRTARTION RTV RTR
|
|
|
+DraAvwailainblegasTsyhpowen:: Unit Dimension
|
|
|
+ EA OA EA OA
|
|
|
+
|
|
|
+Version: MAY18 FA
|
|
|
+
|
|
|
+ FA RA
|
|
|
+ RA
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+ 2 1/8"
|
|
|
+64 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE1.5XRT (RTH/RTF) Energy Recovery Ventilator SEtCanMdoatrodr oOrpEtiConMotor Option
|
|
|
+
|
|
|
+ CURB 1.5X 28 1/4" 45 3/4" Case ABBREVIATIONS
|
|
|
+ O.D. 11 1/8" EA: Exhaust Air to outside
|
|
|
+ 4 1/4" 1 1/8" OA: Outside Air intake
|
|
|
+17 1/8" I.D. 17 1/8" I.D. 15 3/8" RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+24 1/2" A A FA (RTF) 32 5/8" RTF: Rooftop Vertical FA Only
|
|
|
+ I.D. FA RA 14" x 16" Case RTH: Rooftop Horizontal RA & FA
|
|
|
+ Opening INSTALLATION ORIENTATION
|
|
|
+ Unit must be installed in orientation
|
|
|
+ 1 7/8" 38 1/2" I.D. 10 1/8" Door Door 24 3/4" shown.
|
|
|
+ 42 1/4" O.D. FA (RTF) Swing Swing Minimum NOTE:
|
|
|
+ Damper Location Service 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ (Optional) DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ Area NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ TOP VIEW
|
|
|
+
|
|
|
+CURB CROSS-SECTION A-A (TYP.) 55 5/8" Minimum
|
|
|
+ Service Area
|
|
|
+ 1 1/2" X 1/4" 1 7/8"
|
|
|
+ Neoprene Gasket TOP VIEW
|
|
|
+
|
|
|
+ 3/4" X 3 1/2"
|
|
|
+ Wooden Nailer
|
|
|
+
|
|
|
+ 3" 86" Overall 33 1/4"
|
|
|
+ 42 7/8" Lift Lugs
|
|
|
+ SECTION A-A Overall
|
|
|
+ 29 3/4"
|
|
|
+ EA Damper
|
|
|
+ Location Lift Lugs
|
|
|
+ (Optional)
|
|
|
+56 3/4" EA OA RA
|
|
|
+ Overall FA (RTH) 18" X 18"
|
|
|
+ 18" X 18" E-Box RA Duct Receiving
|
|
|
+ 54" Duct Receiving Disconnect Flange
|
|
|
+ Case Flange Pressure
|
|
|
+ Switch Ports (4) Typ.
|
|
|
+
|
|
|
+ 22 1/8" FA RTH 1 7/8"
|
|
|
+ Wiring ONLY 6"
|
|
|
+
|
|
|
+ 3 5/8" CL 5 5/8" Power In FA
|
|
|
+
|
|
|
+CL 26 1/8" LEFT VIEW 5 7/8" FA (RTH) CL 2 1/2" Control In RTF 6 3/8"
|
|
|
+ Wiring
|
|
|
+ Damper Location (2) 7/8" holes for ONLY RIGHT VIEW
|
|
|
+
|
|
|
+ (Optional) wiring in bottom of UNIT MOUNTING & APPLICATION
|
|
|
+ Must be mounted as shown. Airstreams can not be
|
|
|
+ HERT except 6x 8x, LEER-TBox HERTexcept 6x 8x, LERT switched. Duct configuration is field convertible.
|
|
|
+
|
|
|
+ FRONT VIEW
|
|
|
+
|
|
|
+DMroaAAvdIwaRielaFinblL:legOHasW TEsy1hpoC.w5eOnX::NRUFTnIHGit/UDRRTiAmFTeIOnNsion RTH RTF
|
|
|
+ EA
|
|
|
+ EA OA OA
|
|
|
+ FA RA RA
|
|
|
+
|
|
|
+Version: MAY18 FA
|
|
|
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 65
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 2XINH Energy Recovery Ventilator
|
|
|
+ Standarrdd & Bypass Economizer Option
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS Options:
|
|
|
+ Onboard variable frequency drives (VFDs) -
|
|
|
+Download specification at: Ventilation Type:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ Typical Airflow Range: 500-2,200 CFM Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ AHRI 1060 Certified Core: Two L125-G5
|
|
|
+ enhanced, premium
|
|
|
+ Standard Features: Bypass economizer damper
|
|
|
+ TEFC Premium efficiency motors
|
|
|
+ Motor starters (see bypass DIM drawing) -
|
|
|
+ Non-fused disconnect dry-bulb temperature controls (standard),
|
|
|
+ 24 VAC transformer/relay package enthalpy controls (option)
|
|
|
+ Cross-core differential pressure ports Class 1 low leakage motorized isolation dampers -
|
|
|
+ OA, RA or both airstreams
|
|
|
+ Filters: Qty. 2, Factory mounted filter alarms -
|
|
|
+ Total qty. 4, MERV 8: 20" x 20" x 2" both airstreams
|
|
|
+ Double wall construction
|
|
|
+ Unit Dimensions & Weight: Exterior paint - white, custom colors
|
|
|
+ 64 1/2" L x 43" W x 35 1/2" H
|
|
|
+ 406-619 lbs., varies by option(s) Accessories:
|
|
|
+ Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Digital time clock - wall mount (TC7D-W),
|
|
|
+ 70" L x 47" W x 40" H
|
|
|
+ 714 lbs. in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ Motor(s):
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+ with adjustable sheaves (see table below)
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+ Sheave External Static Pressure (in. w.g.)
|
|
|
+ Adj.
|
|
|
+Motor Blower Turns 0.00 0.25Thermal Perfor0m.50ance Ratings G50.270515.2.xlsx 1.00 12.2C5ores (IOM) 1.50
|
|
|
+ HP RPM Open SCFM BHP SCFM BHP SCFM BHP
|
|
|
+ 1592 0.7 SCFM BHP SCFM BHP SCFM BHP SCFM BHP
|
|
|
+ 1.5 1148 4 1809 1.0
|
|
|
+ 1304 2025 1.5 1480 0.7 1320 0.6 1120 0.5 800 0.4
|
|
|
+ 2.0 1460 2 2130 1.6
|
|
|
+ 1506 1720 1.0 1600 0.9 1410 0.8 1250 0.7 975 0.6 630 0.4
|
|
|
+ 1584 0
|
|
|
+ 1661 1950 1.4 1845 1.3 1715 1.2 1540 1.1 1400 1.0 1165 0.8
|
|
|
+ 2
|
|
|
+ 2050 1.5 1955 1.4 1840 1.3 1735 1.2 1585 1.0 1360 0.9
|
|
|
+ 1
|
|
|
+ 2170 1.8 2080 1.7 1970 1.5 1870 1.4 1765 1.3 1565 1.1
|
|
|
+ 0
|
|
|
+ 2200 1.9 2100 1.8 2000 1.7 1900 1.5 1765 1.4
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits. Operation in this zone outside of core airflow limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+ Standard Electrical Specifications
|
|
|
+ Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+ FLA Min. Cir. Max. FLA Min. Cir. Max. 500 1000 1500 2000
|
|
|
+ per motor Amps Overcurrent per motor Amps Overcurrent 90%
|
|
|
+HP Volts HZ Phase Protection Protection Effectiveness (%)
|
|
|
+
|
|
|
+ Device Device
|
|
|
+
|
|
|
+1.5 120 60 Single 15.2 34.2 45 70%
|
|
|
+
|
|
|
+ 208-230 60 Single 8.2-7.6 18.5 25 4.6-4.8 20.6 25 50%
|
|
|
+ 15
|
|
|
+1.5 208-230 60 Three 4.6-4.8 10.8 15 4.6-4.8 11.9 15
|
|
|
+ 460 60 Three 2.4 5.4 15
|
|
|
+ 2.4 5.9 15
|
|
|
+ 60
|
|
|
+ 575 60 Three 1.8 4.1 1.8 4.5 15 30%
|
|
|
+ 35
|
|
|
+2.0 120 60 Single 20.0 45.0 20 At AHRI 1060 standard conditions.
|
|
|
+ 15 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+ 208-230 60 Single 10.8-10.0 24.3 15 6.6-5.8 28.3 30
|
|
|
+
|
|
|
+2.0 208-230 60 Three 6.6-5.8 14.9 6.6-5.8 16.3 20
|
|
|
+ 460 60 Three 2.9 6.5
|
|
|
+ 2.9 7.2 15
|
|
|
+
|
|
|
+ 575 60 Three 2.4 5.4 2.4 5.9 15
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+66 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE2XINH Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 67
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+ AIRFLOW CONFIGURATION
|
|
|
+ Must be mounted as shown. RA/EA airstream can
|
|
|
+ Availableasshown in dimension drawing. be switched with OA/FA airstream unless certain
|
|
|
+ options are selected.
|
|
|
+
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 2XINH Energy Recovery Ventilator
|
|
|
+ Standard with Bypass Economizer
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS Options:
|
|
|
+ Onboard variable frequency drives (VFDs) -
|
|
|
+Download specification at: Ventilation Type:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ Typical Airflow Range: 500-2,200 CFM Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ AHRI 1060 Certified Core: Two L125-G5
|
|
|
+ enhanced, premium
|
|
|
+ Standard Features: Bypass economizer damper
|
|
|
+ TEFC Premium efficiency motors
|
|
|
+ Motor starters (see bypass DIM drawing) -
|
|
|
+ Non-fused disconnect dry-bulb temperature controls (standard),
|
|
|
+ 24 VAC transformer/relay package enthalpy controls (option)
|
|
|
+ Cross-core differential pressure ports Class 1 low leakage motorized isolation dampers -
|
|
|
+ OA, RA or both airstreams
|
|
|
+ Filters: Qty. 2, Factory mounted filter alarms -
|
|
|
+ Total qty. 4, MERV 8: 20" x 20" x 2" both airstreams
|
|
|
+ Double wall construction
|
|
|
+ Unit Dimensions & Weight: Exterior paint - white, custom colors
|
|
|
+ 64 1/2" L x 43" W x 35 1/2" H
|
|
|
+ 406-619 lbs., varies by option(s) Accessories:
|
|
|
+ Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Digital time clock - wall mount (TC7D-W),
|
|
|
+ 70" L x 47" W x 40" H
|
|
|
+ 714 lbs. in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ Motor(s):
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+ with adjustable sheaves (see table below)
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+ Sheave External Static Pressure (in. w.g.)
|
|
|
+ Adj.
|
|
|
+Motor Blower Turns 0.00 0.25Thermal Perfor0m.50ance Ratings G50.270515.2.xlsx 1.00 12.2C5ores (IOM) 1.50
|
|
|
+ HP RPM Open SCFM BHP SCFM BHP SCFM BHP
|
|
|
+ 1592 0.7 SCFM BHP SCFM BHP SCFM BHP SCFM BHP
|
|
|
+ 1.5 1148 4 1809 1.0
|
|
|
+ 1304 2025 1.5 1480 0.7 1320 0.6 1120 0.5 800 0.4
|
|
|
+ 2.0 1460 2 2130 1.6
|
|
|
+ 1506 1720 1.0 1600 0.9 1410 0.8 1250 0.7 975 0.6 630 0.4
|
|
|
+ 1584 0
|
|
|
+ 1661 1950 1.4 1845 1.3 1715 1.2 1540 1.1 1400 1.0 1165 0.8
|
|
|
+ 2
|
|
|
+ 2050 1.5 1955 1.4 1840 1.3 1735 1.2 1585 1.0 1360 0.9
|
|
|
+ 1
|
|
|
+ 2170 1.8 2080 1.7 1970 1.5 1870 1.4 1765 1.3 1565 1.1
|
|
|
+ 0
|
|
|
+ 2200 1.9 2100 1.8 2000 1.7 1900 1.5 1765 1.4
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits. Operation in this zone outside of core airflow limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+ Standard Electrical Specifications
|
|
|
+ Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+ FLA Min. Cir. Max. FLA Min. Cir. Max. 500 1000 1500 2000
|
|
|
+ per motor Amps Overcurrent per motor Amps Overcurrent 90%
|
|
|
+HP Volts HZ Phase Protection Protection Effectiveness (%)
|
|
|
+
|
|
|
+ Device Device
|
|
|
+
|
|
|
+1.5 120 60 Single 15.2 34.2 45 70%
|
|
|
+
|
|
|
+ 208-230 60 Single 8.2-7.6 18.5 25 4.6-4.8 20.6 25 50%
|
|
|
+ 15
|
|
|
+1.5 208-230 60 Three 4.6-4.8 10.8 15 4.6-4.8 11.9 15
|
|
|
+ 460 60 Three 2.4 5.4 15
|
|
|
+ 2.4 5.9 15
|
|
|
+ 60
|
|
|
+ 575 60 Three 1.8 4.1 1.8 4.5 15 30%
|
|
|
+ 35
|
|
|
+2.0 120 60 Single 20.0 45.0 20 At AHRI 1060 standard conditions.
|
|
|
+ 15 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+ 208-230 60 Single 10.8-10.0 24.3 15 6.6-5.8 28.3 30
|
|
|
+
|
|
|
+2.0 208-230 60 Three 6.6-5.8 14.9 6.6-5.8 16.3 20
|
|
|
+ 460 60 Three 2.9 6.5
|
|
|
+ 2.9 7.2 15
|
|
|
+
|
|
|
+ 575 60 Three 2.4 5.4 2.4 5.9 15
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+68 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE2XINH Energy Recovery Ventilator Standard with Bypass Economizer
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 69
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+ AIRFLOW CONFIGURATION
|
|
|
+ Availableasshownindimensiondrawing.
|
|
|
+
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+
|
|
|
+ Must be mounted as shown. Airstreams can not
|
|
|
+ be switched.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 2XINV Energy Recovery Ventilator
|
|
|
+ Standarrdd & Bypass Economizer Option
|
|
|
+INDOOR UNIT
|
|
|
+ SPECIFICATIONS Options:
|
|
|
+Download specification at: Onboard variable frequency drives (VFDs) -
|
|
|
+renewaire.com/specifications Ventilation Type:
|
|
|
+ Static plate, heat and humidity transfer one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ Typical Airflow Range: 500-2,200 CFM Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ AHRI 1060 Certified Core: Two L125-G5
|
|
|
+ enhanced, premium
|
|
|
+ Standard Features: Bypass economizer damper
|
|
|
+ TEFC Premium efficiency motors
|
|
|
+ Motor starters (see bypass DIM drawing) -
|
|
|
+ Non-fused disconnect dry-bulb temperature controls (standard),
|
|
|
+ 24 VAC transformer/relay package enthalpy controls (option)
|
|
|
+ Cross-core differential pressure ports Class 1 low leakage motorized isolation dampers -
|
|
|
+ OA, RA or both airstreams
|
|
|
+ Filters: Qty. 2, Factory mounted filter alarms -
|
|
|
+ Total qty. 4, MERV 8: 20" x 20" x 2" both airstreams
|
|
|
+ Double wall construction
|
|
|
+ Unit Dimensions & Weight: Exterior paint - white, custom colors
|
|
|
+ 50 1/2" L x 42" W x 52 1/2" H
|
|
|
+ 363-583 lbs., varies by option(s) Accessories:
|
|
|
+ Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Digital time clock - wall mount (TC7D-W),
|
|
|
+ 70" L x 47" W x 57" H
|
|
|
+ 678 lbs. in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ Motor(s):
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+ with adjustable sheaves (see table below)
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+ Sheave External Static Pressure (in. w.g.)
|
|
|
+ Adj.
|
|
|
+Motor Blower Turns 0.00 0.25 0.50 0.75 1.00 1.25 1.50
|
|
|
+ HP RPM Open SCFM BHP Thermal Performance Ratings G5 2015.2.xlsx 2 Cores (IOM)
|
|
|
+ 1735 0.8 SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP
|
|
|
+ 1.5 1146 4 1975 1.1
|
|
|
+ 1302 1670 0.7 1520 0.7 1205 0.5 900 0.4
|
|
|
+ 2.0 1458 2
|
|
|
+ 1503 1925 1.1 1835 1.0 1615 0.9 1340 0.8 1080 0.6 670 0.4
|
|
|
+ 1581 0
|
|
|
+ 1658 2100 1.5 1970 1.4 1755 1.3 1495 1.1 1280 0.9
|
|
|
+ 2
|
|
|
+ 2175 1.7 2100 1.6 1945 1.4 1700 1.2 1465 1.0
|
|
|
+ 1
|
|
|
+ 2120 1.7 1920 1.5 1685 1.2
|
|
|
+ 0
|
|
|
+ 2125 1.9 1900 1.6
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits. Operation in this zone outside of core airflow limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+ Max. Max. 500 1000 1500 2000
|
|
|
+ 90%
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Overcurrent FLA Min. Cir. Overcurrent Effectiveness (%)
|
|
|
+ per motor Amps Protection per motor Amps Protection
|
|
|
+
|
|
|
+ Device Device 70%
|
|
|
+
|
|
|
+1.5 120 60 Single 15.2 34.2 45
|
|
|
+
|
|
|
+ 208-230 60 Single 8.2-7.6 18.5 25 4.6-4.8 20.6 25 50%
|
|
|
+
|
|
|
+1.5 208-230 60 Three 4.6-4.8 10.8 15 4.6-4.8 11.9 15
|
|
|
+ 460 60 Three 2.4 5.4 15
|
|
|
+ 15 2.4 5.9
|
|
|
+
|
|
|
+ 575 60 Three 1.8 4.1 15 1.8 4.5 15 30%
|
|
|
+
|
|
|
+2.0 120 60 Single 20.0 45.0 60 At AHRI 1060 standard conditions.
|
|
|
+ See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+ 208-230 60 Single 10.8-10.0 24.3 35 6.6-5.8 28.3 30
|
|
|
+
|
|
|
+2.0 208-230 60 Three 6.6-5.8 14.9 20 6.6-5.8 16.3 20
|
|
|
+ 460 60 Three 2.9 6.5 15
|
|
|
+ 15 2.9 7.2
|
|
|
+
|
|
|
+ 575 60 Three 2.4 5.4 15 2.4 5.9 15
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+70 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE2XINV Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ 50 3/8" Overall ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ 42" Overall OA: Outside Air intake
|
|
|
+ 41 5/8" Case RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ Door 33 5/8" Minimum INSTALLATION ORIENTATION
|
|
|
+ Swing Service Area Unit must be installed in orientation
|
|
|
+ shown.
|
|
|
+ NOTE
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3. MIN. DUCT CLEARANCE FROM
|
|
|
+ DAMPER BLADES WHEN FULLY
|
|
|
+ OPENED TO BE 2". SMACNA RULES
|
|
|
+ APPLY.
|
|
|
+
|
|
|
+ RA Damper RA Inlet 5" Damper 45 1/4" Minimum OA Damper OA Inlet
|
|
|
+ Location 24" X 14" Frames Typ. Service Area Location 24" X 14"
|
|
|
+ (Optional) Duct Receiving (Optional) Duct Receiving
|
|
|
+ Flange RA TOP VIEW Flange
|
|
|
+ 8 1/4" Typ.
|
|
|
+ E-Box 34 7/8" Case
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 71 OA
|
|
|
+
|
|
|
+ 52 3/8" Overall Pressure Ports 3/4" - 1 7/8"
|
|
|
+ 51 5/8" Case (4) Typ. Typ.
|
|
|
+ 9 3/8"
|
|
|
+ Wiring 1 3/4" Typ.
|
|
|
+ 37" Typ.
|
|
|
+
|
|
|
+ FA EA
|
|
|
+
|
|
|
+ CL 5 3/8" Disconnect 4 1/4" Duct
|
|
|
+ Wiring Switch Flange Typ.
|
|
|
+
|
|
|
+ CL 5 3/4" Power In 16" X 12" 10 3/8" Typ.
|
|
|
+ CL 2 5/8" Control In Duct Receiving
|
|
|
+ (2) 7/8" Holes
|
|
|
+ for Wiring in Flange Typ.
|
|
|
+ Bottom of E-Box
|
|
|
+
|
|
|
+ LEFT VIEW FRONT VIEW RIGHT VIEW
|
|
|
+
|
|
|
+ AIRFLOW CONFIGURATION UNIT MOUNTING & APPLICATION
|
|
|
+ Must be mounted as shown. RA/EA airstream can
|
|
|
+ MoAdvaeilal:bleHaEs2shXowINn Vin dimension drawing. be switched with OA/FA airstream unless certain
|
|
|
+ Drawing Type: Unit Dimension options are selected.
|
|
|
+ Version: MAY18
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 2XINV Energy Recovery Ventilator
|
|
|
+ Standard with Bypass Economizer
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS Options:
|
|
|
+ Onboard variable frequency drives (VFDs) -
|
|
|
+Download specification at: Ventilation Type:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ Typical Airflow Range: 500-2,200 CFM Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ AHRI 1060 Certified Core: Two L125-G5
|
|
|
+ enhanced, premium
|
|
|
+ Standard Features: Bypass economizer damper
|
|
|
+ TEFC Premium efficiency motors
|
|
|
+ Motor starters (see bypass DIM drawing) -
|
|
|
+ Non-fused disconnect dry-bulb temperature controls (standard),
|
|
|
+ 24 VAC transformer/relay package enthalpy controls (option)
|
|
|
+ Cross-core differential pressure ports Class 1 low leakage motorized isolation dampers -
|
|
|
+ OA, RA or both airstreams
|
|
|
+ Filters: Qty. 2, Factory mounted filter alarms -
|
|
|
+ Total qty. 4, MERV 8: 20" x 20" x 2" both airstreams
|
|
|
+ Double wall construction
|
|
|
+ Unit Dimensions & Weight: Exterior paint - white, custom colors
|
|
|
+ 50 1/2" L x 42" W x 52 1/2" H
|
|
|
+ 363-583 lbs., varies by option(s) Accessories:
|
|
|
+ Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Digital time clock - wall mount (TC7D-W),
|
|
|
+ 70" L x 47" W x 57" H
|
|
|
+ 678 lbs. in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ Motor(s):
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+ with adjustable sheaves (see table below)
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+ Sheave External Static Pressure (in. w.g.)
|
|
|
+ Adj.
|
|
|
+Motor Blower Turns 0.00 0.25 0.50 0.75 1.00 1.25 1.50
|
|
|
+ HP RPM Open SCFM BHP Thermal Performance Ratings G5 2015.2.xlsx 2 Cores (IOM)
|
|
|
+ 1735 0.8 SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP
|
|
|
+ 1.5 1146 4 1975 1.1
|
|
|
+ 1302 1670 0.7 1520 0.7 1205 0.5 900 0.4
|
|
|
+ 2.0 1458 2
|
|
|
+ 1503 1925 1.1 1835 1.0 1615 0.9 1340 0.8 1080 0.6 670 0.4
|
|
|
+ 1581 0
|
|
|
+ 1658 2100 1.5 1970 1.4 1755 1.3 1495 1.1 1280 0.9
|
|
|
+ 2
|
|
|
+ 2175 1.7 2100 1.6 1945 1.4 1700 1.2 1465 1.0
|
|
|
+ 1
|
|
|
+ 2120 1.7 1920 1.5 1685 1.2
|
|
|
+ 0
|
|
|
+ 2125 1.9 1900 1.6
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits. Operation in this zone outside of core airflow limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+ Standard Electrical Specifications
|
|
|
+ Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+ Max. Max. 500 1000 1500 2000
|
|
|
+ Overcurrent Overcurrent 90%
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Protection FLA Min. Cir. Protection Effectiveness (%)
|
|
|
+ per motor Amps per motor Amps
|
|
|
+ Device Device
|
|
|
+ 70%
|
|
|
+1.5 120 60 Single 15.2 34.2 45
|
|
|
+
|
|
|
+ 208-230 60 Single 8.2-7.6 18.5 25 4.6-4.8 20.6 25 50%
|
|
|
+ 15
|
|
|
+1.5 208-230 60 Three 4.6-4.8 10.8 15 4.6-4.8 11.9 15
|
|
|
+ 460 60 Three 2.4 5.4 15
|
|
|
+ 2.4 5.9 15
|
|
|
+ 60
|
|
|
+ 575 60 Three 1.8 4.1 1.8 4.5 15 30%
|
|
|
+ 35
|
|
|
+2.0 120 60 Single 20.0 45.0 20 At AHRI 1060 standard conditions.
|
|
|
+ 15 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+ 208-230 60 Single 10.8-10.0 24.3 15 6.6-5.8 28.3 30
|
|
|
+
|
|
|
+2.0 208-230 60 Three 6.6-5.8 14.9 6.6-5.8 16.3 20
|
|
|
+ 460 60 Three 2.9 6.5
|
|
|
+ 2.9 7.2 15
|
|
|
+
|
|
|
+ 575 60 Three 2.4 5.4 2.4 5.9 15
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+72 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE2XINV Energy Recovery Ventilator Standard with Bypass Economizer
|
|
|
+
|
|
|
+ 51 1/2" Overall ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ 16" X 16" Bypass Duct Connection OA: Outside Air intake
|
|
|
+ (Direct Mount to Damper, By Others) RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ BP BP: Bypass Air Intake
|
|
|
+
|
|
|
+ 42" Overall INSTALLATION ORIENTATION
|
|
|
+ 41 5/8" Case Unit must be installed in orientation
|
|
|
+ 33 5/8" Minimum shown.
|
|
|
+ Service Area
|
|
|
+ RA OA NOTE
|
|
|
+ Face Bypass 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ Damper Damper DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ FA EA
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ BYPASS AIRFLOW SCHEMATIC Door 3. MIN. DUCT CLEARANCE
|
|
|
+ Swing FROM DAMPER BLADE WHEN FULLY
|
|
|
+ FRONT VIEW OPENED TO BE 2". SMACNA RULES
|
|
|
+ APPLY.
|
|
|
+
|
|
|
+ 34 7/8" Minimum 4. UNITS WITH BYPASS WILL REQUIRE
|
|
|
+ Service Area ADDITIONAL SPACE FOR THE
|
|
|
+ CONNECTION OF THE BYPASS DUCT
|
|
|
+ TOP VIEW (BY OTHERS).
|
|
|
+
|
|
|
+ RA Inlet Isolation Damper 5. FOR INSTALLATION DETAILS, REFER
|
|
|
+ 24" X 14" (Optional) TO I&O MANUAL SUPPLEMENT FOR
|
|
|
+ Duct Receiving Acts as Face Damper BYPASS.
|
|
|
+ Flange for Bypass Units
|
|
|
+ OA Inlet
|
|
|
+ 8 1/4"
|
|
|
+ 5" Damper 4 1/4" Duct 24" X 14"
|
|
|
+ Frames Typ. Flange Typ.
|
|
|
+ 34 7/8" Case Duct Receiving 8 1/4"
|
|
|
+ RA OA Flange OA Damper
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 73
|
|
|
+ E-Box BP Location
|
|
|
+
|
|
|
+ (Optional)
|
|
|
+
|
|
|
+ 52 3/8" Overall
|
|
|
+ 51 5/8" Case
|
|
|
+ 9 3/8"
|
|
|
+ Wiring
|
|
|
+ 37"
|
|
|
+ 3/4" - 1 7/8"
|
|
|
+ Typ.
|
|
|
+ 17 5/8"
|
|
|
+ 1 3/4" Typ.
|
|
|
+ 37"
|
|
|
+ Bypass FA EA
|
|
|
+ Location CL 5 3/8" CL 5 3/4" Power In 16" X 16" 10 3/8"
|
|
|
+ Wiring Disconnect CL 2 5/8" Control In Pressure Ports Bypass 12 3/8"
|
|
|
+ 16" X 12" Switch (2) 7/8" Holes (4) Typ.
|
|
|
+ Duct Receiving for Wiring in Damper
|
|
|
+ Bottom of E-Box Location
|
|
|
+ Flange Typ. (Optional)
|
|
|
+ FRONT VIEW
|
|
|
+ LEFT VIEW RIGHT VIEW
|
|
|
+ MAoIRdFeLlO: HWEC2XOINNFVIG[BUyRpAaTIsOs]N
|
|
|
+ DArvaailwablienags sThoywpnein:dUimnenistioDn dimraweinng.sion UNIT MOUNTING & APPLICATION
|
|
|
+ Version: MAY18
|
|
|
+ Must be mounted as shown. Airstreams can not
|
|
|
+ be switched.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 2XRT Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+ROOFTOP UNIT SPECIFICATIONS Options:
|
|
|
+ Onboard variable frequency drives (VFDs) -
|
|
|
+Download specification at: Ventilation Type:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ Typical Airflow Range: 500-2,000 CFM Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ AHRI 1060 Certified Core: Two L125-G5
|
|
|
+ enhanced, premium
|
|
|
+ Standard Features: Class 1 low leakage motorized isolation dampers -
|
|
|
+ TEFC Premium efficiency motors
|
|
|
+ Motor starters OA, RA or both airstreams
|
|
|
+ Non-fused disconnect Qty. 2, Factory mounted filter alarms -
|
|
|
+ 24 VAC transformer/relay package
|
|
|
+ Cross-core differential pressure ports both airstreams
|
|
|
+ Double wall construction
|
|
|
+ Filters: Exterior paint - white, custom colors
|
|
|
+ Total qty. 4, MERV 8: 20" x 20" x 2"
|
|
|
+ Accessories:
|
|
|
+ Unit Dimensions & Weight: Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 87 1/2" L x 43 1/4" W x 44" H Roof curb - standard 14"
|
|
|
+ 498-689 lbs., varies by option(s) Curb wind clip
|
|
|
+ Engineered combo curb for Carrier RTU
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Engineered combo curb for Trane RTU
|
|
|
+ 96" L x 47" W x 50" H Digital time clock - wall mount (TC7D-W),
|
|
|
+ 784 lbs.
|
|
|
+ in exterior enclosure (TC7D-E)
|
|
|
+ Motor(s): Carbon dioxide sensor/control -
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ with adjustable sheaves (see table below) IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+ Sheave External Static Pressure (in. w.g.)
|
|
|
+ Adj.
|
|
|
+Motor Blower Turns 0.00 0.25Thermal Perfor0m.50ance Ratings G50.270515.2.xlsx 1.00 12.2C5ores (IOM) 1.50
|
|
|
+ HP RPM Open SCFM BHP SCFM BHP SCFM BHP
|
|
|
+ 1560 0.7 SCFM BHP SCFM BHP SCFM BHP SCFM BHP
|
|
|
+ 1.5 1192 4 1765 1.1
|
|
|
+ 1348 1970 1.5 1460 0.7 1300 0.6 1100 0.5 845 0.4
|
|
|
+ 2.0 1504 2 2087 1.6
|
|
|
+ 1516 2194 1.8 1685 1.0 1560 0.9 1380 0.8 1210 0.7 975 0.6 650 0.4
|
|
|
+ 1594 0
|
|
|
+ 1671 1900 1.4 1800 1.3 1670 1.2 1500 1.1 1345 1.0 1135 0.8
|
|
|
+ 2
|
|
|
+ 2000 1.5 1915 1.4 1775 1.2 1635 1.1 1475 1.0 1260 0.8
|
|
|
+ 1
|
|
|
+ 2110 1.7 2035 1.6 1920 1.5 1765 1.3 1630 1.2 1470 1.1
|
|
|
+ 0
|
|
|
+ 2145 1.9 2050 1.7 1905 1.5 1775 1.4 1640 1.3
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits. Operation in this zone outside of core airflow limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+ Standard Electrical Specifications
|
|
|
+ Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+ FLA Min. Cir. Max. FLA Min. Cir. Max. 500 1000 1500 2000
|
|
|
+ per motor Amps Overcurrent per motor Amps Overcurrent 90%
|
|
|
+HP Volts HZ Phase Protection Protection Effectiveness (%)
|
|
|
+
|
|
|
+ Device Device
|
|
|
+
|
|
|
+1.5 120 60 Single 15.2 34.2 45 70%
|
|
|
+
|
|
|
+ 208-230 60 Single 8.2-7.6 18.5 25 4.6-4.8 20.6 25 50%
|
|
|
+ 15
|
|
|
+1.5 208-230 60 Three 4.6-4.8 10.8 15 4.6-4.8 11.9 15
|
|
|
+ 460 60 Three 2.4 5.4 15
|
|
|
+ 2.4 5.9 15
|
|
|
+ 60
|
|
|
+ 575 60 Three 1.8 4.1 1.8 4.5 15 30%
|
|
|
+ 35 At AHRI 1060 standard conditions.
|
|
|
+2.0 120 60 Single 20.0 45.0 20 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+ 15
|
|
|
+ 208-230 60 Single 10.8-10.0 24.3 15 6.6-5.8 28.3 30
|
|
|
+
|
|
|
+2.0 208-230 60 Three 6.6-5.8 14.9 6.6-5.8 16.3 20
|
|
|
+ 460 60 Three 2.9 6.5
|
|
|
+ 2.9 7.2 15
|
|
|
+
|
|
|
+ 575 60 Three 2.4 5.4 2.4 5.9 15
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+74 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE2XRT (RTV/RTR) Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ CURB 2X FA (RTV) 16 7/8" 51" Case ABBREVIATIONS
|
|
|
+ Opening 9 1/2" EA: Exhaust Air to outside
|
|
|
+ 44" I.D. 8 1/4" X 7" 19 5/8" OA: Outside Air intake
|
|
|
+ RA: Room Air to be exhausted
|
|
|
+12 5/8" 12 5/8" RA RA FA: Fresh Air to inside
|
|
|
+ Opening RTV: Rooftop Vertical RA & FA
|
|
|
+38 1/8" 34 3/8" 42 3/8" Case 12" 31" X 10" RTR: Rooftop Vertical RA Only
|
|
|
+ O.D. I.D. 20 3/8" INSTALLATION ORIENTATION
|
|
|
+ FA RA 33 3/4" Unit must be installed in orientation
|
|
|
+ 26 1/4" A A 1/8" Minimum shown.
|
|
|
+ 4" Service Area NOTE:
|
|
|
+ 2 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ Typ. DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 47 3/4" O.D. 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ TOP VIEW Door RA Damper
|
|
|
+ Swing Location CURB CROSS-SECTION A-A (TYP.)
|
|
|
+ (Optional)
|
|
|
+ 41 1/4" (Recessed 3/4")
|
|
|
+
|
|
|
+ 10 1/8" 61 1/8" Minimum
|
|
|
+ Service Area
|
|
|
+ 1 1T/y8p" . 1 1/2" X 1/4" 1 7/8"
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 75 TOP VIEW Neoprene Gasket
|
|
|
+
|
|
|
+ 3/4" X 3 1/2" 14"
|
|
|
+ Wooden Nailer 3"
|
|
|
+
|
|
|
+ SECTION A-A
|
|
|
+
|
|
|
+ 87 1/2" Overall 43 1/4" Overall
|
|
|
+ 48 1/8" Lifting Lugs
|
|
|
+ 39 1/2"
|
|
|
+ E-Box Lifting Lugs
|
|
|
+ EA
|
|
|
+ 12 3/4" Wiring OA Damper
|
|
|
+ 6 1/8"
|
|
|
+43 7/8" Overall Location
|
|
|
+ 41" Case FA
|
|
|
+ RA OA (Optional)
|
|
|
+
|
|
|
+ FA RTR
|
|
|
+ ONLY
|
|
|
+
|
|
|
+7 1/4" FA (RTR) CL 5 3/8" Disconnect FA Pressure
|
|
|
+ Wiring Switch Ports (4) Typ.
|
|
|
+ 24" X 14" RTV RA
|
|
|
+ CL 5 3/4" Power In ONLY
|
|
|
+ CL 2 5/8" Control In
|
|
|
+
|
|
|
+ (2) 7/8" Holes
|
|
|
+
|
|
|
+ Duct Receiving for Wiring in
|
|
|
+
|
|
|
+ Flange HERT excepBt 6ox 8txt,oLEmRT of E-Box HERT except 6x 8x, LERT
|
|
|
+
|
|
|
+ LEFT VIEW FRONT VIEW RIGHT VIEW
|
|
|
+
|
|
|
+ RTV RTR UNIT MOUNTING & APPLICATION
|
|
|
+ Must be mounted as shown. Airstreams can not
|
|
|
+MDAAroavIaRdiwlaFebiLlnel:OgaHsWsTEhyo2CwpXOne: RN:TFUVIGn/UiRt RTDRAimTIOeNnsion EA OA EA OA be switched.
|
|
|
+
|
|
|
+ FA
|
|
|
+
|
|
|
+Version: MAY18
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+ 1 1T/y8p" .
|
|
|
+76 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE2XRT (RTH/RTF) Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ CURB 2X FA (RTF) 16 7/8" 51" Case 19 5/8" ABBREVIATIONS
|
|
|
+ 8 1/4" X 7" 9 1/2" EA: Exhaust Air to outside
|
|
|
+ 44" I.D. Opening OA: Outside Air intake
|
|
|
+ RA: Room Air to be exhausted
|
|
|
+12 5/8" 12 5/8" FA: Fresh Air to inside
|
|
|
+ 34 3/8" RTF: Rooftop Vertical FA Only
|
|
|
+38 1/8" FA I.D. RTH: Rooftop Horizontal RA & FA
|
|
|
+ O.D. INSTALLATION ORIENTATION
|
|
|
+ A A Typ2. 1/8" Unit must be installed in orientation
|
|
|
+ 26 1/4" 42 3/8" Case shown.
|
|
|
+ 4" 12" NOTE:
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ 47 3/4" O.D. DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ Door 33 3/4" 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ Swing Minimum TO CHANGE WITHOUT NOTICE.
|
|
|
+ Service Area
|
|
|
+ TOP VIEW 61 1/8" Minimum
|
|
|
+ Service Area
|
|
|
+ 10 1/8" CURB CROSS-SECTION A-A (TYP.)
|
|
|
+ TOP VIEW
|
|
|
+ 1 1/2" X 1/4" 1 7/8"
|
|
|
+ Neoprene Gasket
|
|
|
+
|
|
|
+ 3/4" X 3 1/2" 5 7/8"
|
|
|
+ Wooden Nailer 3" 14"
|
|
|
+
|
|
|
+ SECTION A-A
|
|
|
+
|
|
|
+ 87 1/2" Overall 43 1/4" Overall
|
|
|
+ 48 1/8" Lifting Lugs
|
|
|
+ 39 1/2"
|
|
|
+ E-Box Lifting Lugs
|
|
|
+ EA
|
|
|
+ 12 3/4" Wiring OA Damper
|
|
|
+ 6 1/8"
|
|
|
+ Location
|
|
|
+ FA
|
|
|
+44" Overall OA (Optional)
|
|
|
+ 41" Case
|
|
|
+ FA RTH RA
|
|
|
+ ONLY
|
|
|
+ 5" Damper
|
|
|
+7 1/4" FA (RTH) CL 5 3/8" Disconnect FA Frames Typ. RA 8 3/8"
|
|
|
+ Wiring Switch Pressure 24" X 14"
|
|
|
+ RTF Ports (4) Typ. Duct Receiving RA Damper
|
|
|
+ CL 5 3/4" Power In ONLY Location
|
|
|
+ CL 2 5/8" Control In Flange (Optional)
|
|
|
+ 24" X 14"
|
|
|
+ (2) 7/8" Holes
|
|
|
+
|
|
|
+ Duct Receiving for Wiring in
|
|
|
+
|
|
|
+ Flange HERT excepBt 6ox t8txo, LmERT of E-Box HERTexcept 6x 8x, LERT
|
|
|
+
|
|
|
+ LEFT VIEW FRONT VIEW RIGHT VIEW
|
|
|
+
|
|
|
+MAAovIaRdilaFebLlel:OaHsWsEho2CwXOn: RNTFHIG/URTRFATION RTH RTF UNIT MOUNTING & APPLICATION
|
|
|
+
|
|
|
+ EA OA EA OA Must be mounted as shown. Airstreams can not
|
|
|
+ be switched.
|
|
|
+Drawing Type: Unit Dimension FA RA RA
|
|
|
+
|
|
|
+Version: MAY18
|
|
|
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 77
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 2XRTC Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+ROOFTOP UNIT SPECIFICATIONS
|
|
|
+Direct Connect
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Onboard variable frequency drives (VFDs) -
|
|
|
+
|
|
|
+ Typical Airflow Range: 500-1,700 CFM one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ AHRI 1060 Certified Core: Two L125-G5 Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ Standard Features:
|
|
|
+ TEFC Premium efficiency motors enhanced, premium
|
|
|
+ Motor starters Qty. 2, Factory mounted filter alarms -
|
|
|
+ Non-fused disconnect
|
|
|
+ 24 VAC transformer/relay package both airstreams
|
|
|
+ Cross-core differential pressure ports Double wall construction
|
|
|
+ Exterior paint - white, custom colors
|
|
|
+ Filters:
|
|
|
+ Total qty. 4, MERV 8: (2) 20" x 20" x 2" and Accessories:
|
|
|
+ Filters - MERV 13, 2" (shipped loose)
|
|
|
+ (2) 14" x 20" x 2" RTC transition kit - for vertical RTU, for horizontal RTU
|
|
|
+ Rooftop RTC transition paint - white, custom colors
|
|
|
+ Unit Dimensions & Weight: Digital time clock - wall mount (TC7D-W),
|
|
|
+ 77 1/4" L x 61" W x 50" H
|
|
|
+ 566-711 lbs., varies by option(s) in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet):
|
|
|
+ 80" L x 90" W x 50" H wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ 850 lbs. IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ Motor(s): duct mount (IAQ-D)
|
|
|
+ Qty. 2, 2.0 HP ea., Belt drive blower/standard motor Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ packages with adjustable sheaves (see table below) ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+
|
|
|
+ Note: Electric Duct Heater and Indirect Gas-Fired Duct Furnace are not available on RTC units.
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+ Tie-In Directly to Rooftop A/C Unit* Unit Ducted Independently*
|
|
|
+
|
|
|
+ Blower RPM Sheave Adj. Static Pressure in Adjacent Air Handler External Static Pressure (Inches Water Column)
|
|
|
+ Nominal Turns Open (Inches Water Column)
|
|
|
+
|
|
|
+ -0.75 -0.5 -0.25 0.0 +0.25 +0.5 +0.75
|
|
|
+
|
|
|
+ CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
|
|
|
+
|
|
|
+ 1450 0 1664 1.6 1785 1.9 1785 1.9 1664 1.6
|
|
|
+
|
|
|
+ 1370 1 1400 1.4 1570 1.6 1740 1.8 1900 1.9 1740 1.8 1570 1.6 1400 1.4
|
|
|
+
|
|
|
+ 1290 2 1125 1.3 1350 1.4 1575 1.5 1727 1.6 1575 1.5 1350 1.4 1125 1.3
|
|
|
+
|
|
|
+Exhaust Air 1210 3 945 1.0 1165 1.1 1385 1.3 1560 1.4 1385 1.3 1165 1.1 945 1.0
|
|
|
+
|
|
|
+ 1130 4 721 0.7 Th97e8rmal P0e.9rforma12n3c5e Rati1n.g1s G5 12306155.2.xl1s.x1 1235 1.1 9728 Core0s.(9IOM) 721 0.7
|
|
|
+
|
|
|
+ 1050 5 560 0.7 810 0.8 1060 0.9 1200 1.0 1060 0.9 810 0.8 560 0.7
|
|
|
+
|
|
|
+ 945 6 635 0.6 765 0.6 895 0.6 1025 0.7 895 0.6 765 0.6 635 0.6
|
|
|
+
|
|
|
+ 1705 0 1600 2.0 1480 1.9 1360 1.7
|
|
|
+
|
|
|
+ 1610 1 1635 2.0 1555 1.9 1490 1.8 1375 1.7 1260 1.5
|
|
|
+
|
|
|
+ 1515 2 1742 2.0 1631 1.9 1520 1.7 1430 1.6 1355 1.6 1230 1.4 1105 1.3
|
|
|
+
|
|
|
+Fresh Air 1420 3 1620 1.7 1515 1.6 1410 1.5 1300 1.4 1230 1.4 1115 1.2 1000 1.1
|
|
|
+
|
|
|
+ 1325 4 1465 1.5 1370 1.4 1275 1.3 1190 1.3 1120 1.2 995 1.1 870 0.9
|
|
|
+
|
|
|
+ 1230 5 1325 1.3 1245 1.2 1165 1.1 1080 1.0 985 0.9 850 0.8 715 0.6
|
|
|
+
|
|
|
+ 1090 6 1170 1.0 1085 0.9 1000 0.8 905 0.8 824 0.7 743 0.6 662 0.6
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+* See page 30 for installation details.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+ Max. Max. 500 1000 1500 2000
|
|
|
+ 90%
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Overcurrent FLA Min. Cir. Overcurrent Effectiveness (%)
|
|
|
+ per motor Amps Protection per motor Amps Protection
|
|
|
+
|
|
|
+ Device Device 70%
|
|
|
+
|
|
|
+ 208-230 60 Single 10.8-10.0 24.3 35 6.6-5.8 28.3 30
|
|
|
+
|
|
|
+2.0 208-230 60 Three 6.6-5.8 14.9 20 6.6-5.8 16.3 20 50%
|
|
|
+ 460 60 Three 2.9 6.5 15
|
|
|
+ 15 2.9 7.2
|
|
|
+
|
|
|
+ 575 60 Three 2.4 5.4 15 2.4 5.9 15
|
|
|
+
|
|
|
+ 30%
|
|
|
+
|
|
|
+ At AHRI 1060 standard conditions.
|
|
|
+ See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+78 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE2XRTC Energy Recovery Ventilator Standard ABBREVIATION
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ 57 3/4" Case OA: Outside Air intake
|
|
|
+ 1 7/8" RA: Room Air to be exhausted
|
|
|
+ Typ1. 1/8" FA: Fresh Air to inside
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ 2 1T/y8p" . Door Door 33 7/8" Unit must be installed in orientation
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 79 Swing Swing Minimum shown.
|
|
|
+ Service Area NOTE:
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+61" Overall 67 5/8" Minimum 11 1/8" Typ. 14 7/8" - 17 5/8"DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ Service Area Height AdjustmentNEAREST EIGHTH OF AN INCH.
|
|
|
+ 39 1/2" 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ Lifting Lugs TOP VIEW TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 77 1/8" Overall 17 7/8"
|
|
|
+ 54 7/8" 41 3/4" Case
|
|
|
+
|
|
|
+ Lifting Lugs 29"
|
|
|
+ Typ.
|
|
|
+49 7/8" Overall EA FA 4" Typ.
|
|
|
+ 3 5/8" Wiring RA
|
|
|
+ 41" E-Box RIGHT VIEW
|
|
|
+ Case Disconnect
|
|
|
+ OA UNIT MOUNTING & APPLICATION
|
|
|
+ CL 5 1/2" Switch Pressure 23 3/8" Must be mounted as shown. Airstreams can not
|
|
|
+ LEFT VIEW Wiring Ports (4) Typ. 8 7/8" be switched.
|
|
|
+ CL 5 3/4" Power In
|
|
|
+ AIRFLOW CONFIGURATION CL 2 5/8" Control In
|
|
|
+ (2) 7/8" Holes
|
|
|
+ModAevali:labHleEa2s XshRowTnCin dimension drawing. for Wiring in
|
|
|
+Drawing Type: Unit Dimension Bottom of E-Box
|
|
|
+Version: MAY18
|
|
|
+ FRONT VIEW
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 3XINH Energy Recovery Ventilator
|
|
|
+ Standarrdd & Bypass Economizer Option
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Onboard variable frequency drives (VFDs) -
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE Typical Airflow Range: 750-3,300 CFM one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ AHRI 1060 Certified Core: Three L125-G5 Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ Standard Features:
|
|
|
+ TEFC Premium efficiency motors enhanced, premium
|
|
|
+ Motor starters Bypass economizer damper
|
|
|
+ Non-fused disconnect
|
|
|
+ 24 VAC transformer/relay package (see bypass DIM drawing) -
|
|
|
+ Cross-core differential pressure ports dry-bulb temperature controls (standard),
|
|
|
+ enthalpy controls (option)
|
|
|
+ Filters: Class 1 low leakage motorized isolation dampers -
|
|
|
+ Total qty. 6, MERV 8: 20" x 20" x 2" OA, RA or both airstreams
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+ Unit Dimensions & Weight: both airstreams
|
|
|
+ 72 1/2" L x 63 1/4" W x 44" H Double wall construction
|
|
|
+ 628-934 lbs., varies by option(s) Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Accessories:
|
|
|
+ 80" L x 70" W x 50" H Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 1,029 lbs. Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ Motor(s): in exterior enclosure (TC7D-E)
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ with adjustable sheaves (see table below) wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ Sheave External Static Pressure (in. w.g.)
|
|
|
+ Adj.
|
|
|
+Motor Blower Turns 0.00 0.25 0.50 0.75 1.00 1.25 1.50
|
|
|
+ HP RPM Open SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP
|
|
|
+
|
|
|
+ 1189 4 2185 1.0 2095 Th0e.9rmal P1e9r0f0orman0c.e8 Rating1s58G05 20150..62.xlsx 800 0.4 3 Cores (IOM)
|
|
|
+
|
|
|
+2.0 1329 2 2440 1.4 2360 1.3 2220 1.2 2020 1.0 1640 0.8 850 0.4
|
|
|
+
|
|
|
+ 1470 0 2700 1.9 2640 1.8 2520 1.6 2360 1.5 2150 1.8 1770 1.0 1110 0.6
|
|
|
+
|
|
|
+ 1496 3 2905 2.4 2815 2.3 2675 2.1 2505 1.9 2340 1.8 2220 1.6 1655 1.2
|
|
|
+
|
|
|
+3.0 1560 2 3030 2.7 2945 2.6 2825 2.5 2655 2.3 2445 2.1 2325 1.9 1990 1.6
|
|
|
+
|
|
|
+ 1656 0.5 3040 3.0 2875 2.8 2720 2.6 2575 2.4 2380 2.2
|
|
|
+
|
|
|
+ 1688 0 2950 2.9 2800 2.8 2650 2.6 2490 3.0
|
|
|
+
|
|
|
+ 1686 3 3300 3.5 3225 3.4 3015 3.2 2855 3.0 2800 2.8 2645 2.6 2470 2.4
|
|
|
+
|
|
|
+5.0 1764 1.5 3290 3.8 3145 3.5 2995 3.3 2850 3.1 2705 2.9
|
|
|
+ 3300 4.1 3175 3.8 3040 3.6 2900 3.4
|
|
|
+ 1843 0
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits. Operation in this zone outside of core airflow limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+ 1000 1500 2000 2500 3000 3500
|
|
|
+ Max. Max. 500
|
|
|
+ 90%
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Overcurrent FLA Min. Cir. Overcurrent Effectiveness (%)
|
|
|
+ per motor Amps Protection per motor Amps Protection
|
|
|
+
|
|
|
+ Device Device
|
|
|
+
|
|
|
+2.0 120 60 Single 20.0 45.0 60 70%
|
|
|
+
|
|
|
+ 208-230 60 Single 10.8-10.0 24.3 35 6.6-5.8 28.3 30 50%
|
|
|
+
|
|
|
+2.0 208-230 60 Three 6.6-5.8 14.9 20 6.6-5.8 16.3 20 30%
|
|
|
+ 460 60 Three 2.9 6.5 15 At AHRI 1060 standard conditions.
|
|
|
+ 15 2.9 7.2 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ 575 60 Three 2.4 5.4 15 2.4 5.9 15
|
|
|
+
|
|
|
+ 208-230 60 Single 14.7-14 33.1 40 9.4-8.5 40.2 45
|
|
|
+
|
|
|
+3.0 208-230 60 Three 9.4-8.5 21.1 25 9.4-8.5 23.2 25
|
|
|
+ 460 60 Three 4.2 9.5 15
|
|
|
+ 15 4.2 10.5
|
|
|
+
|
|
|
+ 575 60 Three 3.3 7.4 15 3.3 8.2 15
|
|
|
+
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 45 14.5-13.4 35.9 45
|
|
|
+
|
|
|
+5.0 460 60 Three 6.7 15.1 20 6.7 16.6 20
|
|
|
+
|
|
|
+ 575 60 Three 5.3 11.9 15 5.3 13.1 15
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+80 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE3XINH Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ Typ2. 1/8" ABBREVIATIONS
|
|
|
+ 62 1/4" Case EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ Door Door 33 3/4" RA: Room Air to be exhausted
|
|
|
+ Swing Swing Minimum FA: Fresh Air to inside
|
|
|
+ Service Area INSTALLATION ORIENTATION
|
|
|
+ 10 1/8" Unit must be installed in orientation
|
|
|
+ shown.
|
|
|
+ NOTE
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3. MIN. DUCT CLEARANCE
|
|
|
+ FROM DAMPER BLADES WHEN FULLY
|
|
|
+ OPENED TO BE 2". SMACNA RULES
|
|
|
+ APPLY.
|
|
|
+
|
|
|
+ 1 1T/y8p" . 67 5/8" Minimum OA Damper OA Inlet
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 81 Service Area Location 36" X 14"
|
|
|
+ (Optional) Duct Receiving
|
|
|
+ TOP VIEW Flange
|
|
|
+
|
|
|
+35 5/8" 16" X 12" 10 3/8" 72 1/2" Overall 5" Damper 63 1/8" Overall
|
|
|
+ Duct Receiving 4 1/4" Duct 57 1/8" Case Frames Typ. 59 3/8" Lifting Lugs
|
|
|
+ Flange Typ. Flange Typ. 54 1/2" Lifting Lugs
|
|
|
+ OA
|
|
|
+43 7/8" Overall E-Box RA Damper
|
|
|
+ 41" Case Location
|
|
|
+ EA (Optional)
|
|
|
+ 21 7/8"
|
|
|
+ 4 7/8" FA RA 5 7/8"
|
|
|
+ 24 1/2"
|
|
|
+ Disconnect
|
|
|
+ Switch CL 5 3/4" Power In Pressure RA Inlet
|
|
|
+ Ports (4) Typ. 36" X 14"
|
|
|
+ CL 2 5/8" Control In Duct Receiving
|
|
|
+ (2) 7/8" Holes Flange 12 1/4"
|
|
|
+ for Wiring in
|
|
|
+ Bottom of E-Box
|
|
|
+
|
|
|
+ LEFT VIEW FRONT VIEW RIGHT VIEW
|
|
|
+DMroaAAvdwIaRielaiFnbl:LlegOHasTEWsy3hpoXCweIOnN:iNnHUdFinmIGietnUsDiRonimAdTraeIwOninNsgi.on
|
|
|
+Version: MAY18 UNIT MOUNTING & APPLICATION
|
|
|
+
|
|
|
+ Must be mounted as shown. RA/EA airstream can
|
|
|
+ be switched with OA/FA airstream unless certain
|
|
|
+ options are selected.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 3XINH Energy Recovery Ventilator
|
|
|
+ Standard with Bypass Economizer
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Onboard variable frequency drives (VFDs) -
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE Typical Airflow Range: 750-3,300 CFM one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ AHRI 1060 Certified Core: Three L125-G5 Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ Standard Features:
|
|
|
+ TEFC Premium efficiency motors enhanced, premium
|
|
|
+ Motor starters Bypass economizer damper
|
|
|
+ Non-fused disconnect
|
|
|
+ 24 VAC transformer/relay package (see bypass DIM drawing) -
|
|
|
+ Cross-core differential pressure ports dry-bulb temperature controls (standard),
|
|
|
+ enthalpy controls (option)
|
|
|
+ Filters: Class 1 low leakage motorized isolation dampers -
|
|
|
+ Total qty. 6, MERV 8: 20" x 20" x 2" OA, RA or both airstreams
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+ Unit Dimensions & Weight: both airstreams
|
|
|
+ 72 1/2" L x 63 1/4" W x 44" H Double wall construction
|
|
|
+ 628-934 lbs., varies by option(s) Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Accessories:
|
|
|
+ 80" L x 70" W x 50" H Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 1,029 lbs. Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ Motor(s): in exterior enclosure (TC7D-E)
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ with adjustable sheaves (see table below) wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ Sheave External Static Pressure (in. w.g.)
|
|
|
+ Adj.
|
|
|
+Motor Blower Turns 0.00 0.25 0.50 0.75 1.00 1.25 1.50
|
|
|
+ HP RPM Open SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP
|
|
|
+
|
|
|
+ 1189 4 2185 1.0 2095 Th0e.9rmal P1e9r0f0orman0c.e8 Rating1s58G05 20150..62.xlsx 800 0.4 3 Cores (IOM)
|
|
|
+
|
|
|
+2.0 1329 2 2440 1.4 2360 1.3 2220 1.2 2020 1.0 1640 0.8 850 0.4
|
|
|
+
|
|
|
+ 1470 0 2700 1.9 2640 1.8 2520 1.6 2360 1.5 2150 1.8 1770 1.0 1110 0.6
|
|
|
+
|
|
|
+ 1496 3 2905 2.4 2815 2.3 2675 2.1 2505 1.9 2340 1.8 2220 1.6 1655 1.2
|
|
|
+
|
|
|
+3.0 1560 2 3030 2.7 2945 2.6 2825 2.5 2655 2.3 2445 2.1 2325 1.9 1990 1.6
|
|
|
+
|
|
|
+ 1656 0.5 3040 3.0 2875 2.8 2720 2.6 2575 2.4 2380 2.2
|
|
|
+
|
|
|
+ 1688 0 2950 2.9 2800 2.8 2650 2.6 2490 3.0
|
|
|
+
|
|
|
+ 1686 3 3300 3.5 3225 3.4 3015 3.2 2855 3.0 2800 2.8 2645 2.6 2470 2.4
|
|
|
+
|
|
|
+5.0 1764 1.5 3290 3.8 3145 3.5 2995 3.3 2850 3.1 2705 2.9
|
|
|
+ 3300 4.1 3175 3.8 3040 3.6 2900 3.4
|
|
|
+ 1843 0
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits. Operation in this zone outside of core airflow limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+ 1000 1500 2000 2500 3000 3500
|
|
|
+ Max. Max. 500
|
|
|
+ 90%
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Overcurrent FLA Min. Cir. Overcurrent Effectiveness (%)
|
|
|
+ per motor Amps Protection per motor Amps Protection
|
|
|
+
|
|
|
+ Device Device
|
|
|
+
|
|
|
+2.0 120 60 Single 20.0 45.0 60 70%
|
|
|
+
|
|
|
+ 208-230 60 Single 10.8-10.0 24.3 35 6.6-5.8 28.3 30 50%
|
|
|
+
|
|
|
+2.0 208-230 60 Three 6.6-5.8 14.9 20 6.6-5.8 16.3 20 30%
|
|
|
+ 460 60 Three 2.9 6.5 15 At AHRI 1060 standard conditions.
|
|
|
+ 15 2.9 7.2 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ 575 60 Three 2.4 5.4 15 2.4 5.9 15
|
|
|
+
|
|
|
+ 208-230 60 Single 14.7-14 33.1 40 9.4-8.5 40.2 45
|
|
|
+
|
|
|
+3.0 208-230 60 Three 9.4-8.5 21.1 25 9.4-8.5 23.2 25
|
|
|
+ 460 60 Three 4.2 9.5 15
|
|
|
+ 15 4.2 10.5
|
|
|
+
|
|
|
+ 575 60 Three 3.3 7.4 15 3.3 8.2 15
|
|
|
+
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 45 14.5-13.4 35.9 45
|
|
|
+
|
|
|
+5.0 460 60 Three 6.7 15.1 20 6.7 16.6 20
|
|
|
+
|
|
|
+ 575 60 Three 5.3 11.9 15 5.3 13.1 15
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+82 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE3XINH Energy Recovery Ventilator Standard with Bypass Economizer
|
|
|
+
|
|
|
+ 30" X 16" Bypass Duct Connection 18 1/2" ABBREVIATIONS
|
|
|
+ (Direct Mount to Damper, By Others) EA: Exhaust Air to outside
|
|
|
+ 17 3/8" OA: Outside Air intake
|
|
|
+Bypass BP RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+Damper BP: Bypass Air Intake
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+EA OA 2 1/8" Unit must be installed in orientation
|
|
|
+ 62 1/4" Case shown.
|
|
|
+FA RA 30" X 16" Bypass NOTE
|
|
|
+ Damper Location 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ Face Damper (Optional) DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+BYPASS AIRFLOW SCHEMATIC 5" Damper 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ Frames Typ. TO CHANGE WITHOUT NOTICE.
|
|
|
+ FRONT VIEW 3. MIN. DUCT CLEARANCE
|
|
|
+ FROM DAMPER BLADE WHEN FULLY
|
|
|
+ Door Door 33 3/4" OPENED TO BE 2". SMACNA RULES
|
|
|
+ Swing Swing Minimum APPLY.
|
|
|
+ Service Area 4. UNITS WITH BYPASS WILL REQUIRE
|
|
|
+ 8 1/4" ADDITIONAL SPACE FOR THE
|
|
|
+ CONNECTION OF THE BYPASS DUCT
|
|
|
+ 1 1/8" 65 5/8" Minimum (BY OTHERS).
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 83 Service Area 5. FOR INSTALLATION DETAILS, REFER
|
|
|
+ TO I&O MANUAL SUPPLEMENT FOR
|
|
|
+ TOP VIEW BYPASS.
|
|
|
+
|
|
|
+ BP 72 3/4" Overall 63 1/8" Overall
|
|
|
+ 57 1/8" Case
|
|
|
+ 10 3/8" 54 1/2" Lifting Lugs 59 3/8" Lifting Lugs
|
|
|
+ 4 1/4" Duct
|
|
|
+ Flange Typ. OA Damper 12 1/4" OA Inlet
|
|
|
+ Location 36" X 14"
|
|
|
+ E-Box (Optional) Duct
|
|
|
+ Receiving
|
|
|
+47 3/8" Overall EA OA Flange
|
|
|
+ 41" Case
|
|
|
+ FA RA 6"
|
|
|
+ 21 7/8" 24 7/8"
|
|
|
+ 5"
|
|
|
+
|
|
|
+ 16" X 12" CL 5 3/8" Disconnect CL 5 3/4" Power In Pressure RA Inlet Isolation Damper
|
|
|
+ Duct Receiving Wiring Switch CL 2 5/8" Control In Ports (4) Typ. 36" X 14" (Optional)
|
|
|
+ 8 1/2" Typ. (2) 7/8" Holes Duct Receiving Acts as Face Damper
|
|
|
+ Flange Typ. for Wiring in For Bypass Units
|
|
|
+ Bottom of E-Box Flange
|
|
|
+ LEFT VIEW
|
|
|
+ FRONT VIEW RIGHT VIEW
|
|
|
+
|
|
|
+MAIoRFdLeOl:WHEC3OXNINFHIG[UBRyApTaIOssN] UNIT MOUNTING & APPLICATION
|
|
|
+DAvraailawbleinasgshTowynpined:imUennsiitonDdrimawiengn. sion
|
|
|
+Version: MAY18 Must be mounted as shown. Airstreams can not
|
|
|
+ be switched.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 3XINV Energy Recovery Ventilator
|
|
|
+ Standarrdd & Bypass Economizer Option
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS Options:
|
|
|
+ Onboard variable frequency drives (VFDs) -
|
|
|
+Download specification at: Ventilation Type:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer one or both airstreams
|
|
|
+AIRFLOW PERFORMANCE Shaft grounding ring on motors with VFDs
|
|
|
+ Typical Airflow Range: 750-3,300 CFM Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ AHRI 1060 Certified Core: Three L125-G5
|
|
|
+ enhanced, premium
|
|
|
+ Standard Features: Bypass economizer damper
|
|
|
+ TEFC Premium efficiency motors
|
|
|
+ Motor starters (see bypass DIM drawing) -
|
|
|
+ Non-fused disconnect dry-bulb temperature controls (standard),
|
|
|
+ 24 VAC transformer/relay package enthalpy controls (option)
|
|
|
+ Cross-core differential pressure ports Class 1 low leakage motorized isolation dampers -
|
|
|
+ OA, RA or both airstreams
|
|
|
+ Filters: Qty. 2, Factory mounted filter alarms -
|
|
|
+ Total qty. 6, MERV 8: 20" x 20" x 2" both airstreams
|
|
|
+ Double wall construction
|
|
|
+ Unit Dimensions & Weight: Exterior paint - white, custom colors
|
|
|
+ 50 3/4" L x 61 1/2" W x 62" H
|
|
|
+ 590-999 lbs., varies by option(s) Accessories:
|
|
|
+ Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Digital time clock - wall mount (TC7D-W),
|
|
|
+ 60" L x 90" W x 70" H
|
|
|
+ 1,094 lbs. in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ Motor(s):
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+ with adjustable sheaves (see table below)
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ Sheave External Static Pressure (in. w.g.)
|
|
|
+ Adj.
|
|
|
+Motor Blower Turns 0.00 0.25 0.50 0.75 1.00 1.25 1.50
|
|
|
+ HP RPM Open SCFM BHP SCFM BHP SCFM BHP
|
|
|
+ 2.0 2185 0.8 SCFM BHP SCFM BHP SCFM BHP SCFM BHP
|
|
|
+ 1195 4 2440 1.1
|
|
|
+ 3.0 1355 2 2700 1.5 2000 0.7 1725 0.5 1210 0.4 3 Cores (IOM)
|
|
|
+ 1476 0 2810 2.1 Thermal Performance Ratings G5 2015.2.xlsx
|
|
|
+ 5.0 1536 2.5 2985 2.5
|
|
|
+ 1632 1.5 3100 2.8 2270 0.9 2060 0.8 1715 0.6 1210 0.5
|
|
|
+ 1696 0.5 3160 3.0
|
|
|
+ 1728 0 3300 3.3 2550 1.3 2380 1.2 2150 1.0 1750 0.8 1300 0.6
|
|
|
+ 1749 2 1840 1.5 1420 1.1
|
|
|
+ 1801 1 2700 2.1 2560 1.9 2370 1.8 2140 1.6 2145 1.8 1855 1.6
|
|
|
+ 1853 0 2335 2.1 2065 1.9
|
|
|
+ 2880 2.4 2760 2.3 2590 2.2 2400 2.0 2425 2.3 2165 2.1
|
|
|
+ 2440 2.1 2200 1.8
|
|
|
+ 3000 2.7 2900 2.7 2735 2.5 2505 2.3 2585 2.8 2350 2.1
|
|
|
+ 2715 2.6 2500 2.4
|
|
|
+ 3055 2.9 2960 2.8 2800 2.6 2635 2.5
|
|
|
+
|
|
|
+ 3200 3.1 3020 2.8 2860 2.6 2660 2.3
|
|
|
+
|
|
|
+ 3300 3.4 3140 3.1 2980 2.8 2800 2.6
|
|
|
+
|
|
|
+ 3245 3.4 3090 3.1 2920 2.9
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone outside of core airflow limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+ 1000 1500 2000 2500 3000 3500
|
|
|
+ Max. Max. 500
|
|
|
+ 90%
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Overcurrent FLA Min. Cir. Overcurrent Effectiveness (%)
|
|
|
+ per motor Amps Protection per motor Amps Protection
|
|
|
+
|
|
|
+ Device Device
|
|
|
+
|
|
|
+2.0 120 60 Single 20.0 45.0 60 70%
|
|
|
+
|
|
|
+ 208-230 60 Single 10.8-10.0 24.3 35 6.6-5.8 16.3 30 50%
|
|
|
+
|
|
|
+2.0 208-230 60 Three 6.6-5.8 14.9 20 6.6-5.8 28.3 20 30%
|
|
|
+ 460 60 Three 2.9 6.5 15 At AHRI 1060 standard conditions.
|
|
|
+ 15 2.9 7.2 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ 575 60 Three 2.4 5.4 15 2.4 5.9 15
|
|
|
+
|
|
|
+ 208-230 60 Single 14.7-14 33.1 40 9.4-8.5 40.2 45
|
|
|
+
|
|
|
+3.0 208-230 60 Three 9.4-8.5 21.1 25 9.4-8.5 23.2 25
|
|
|
+ 460 60 Three 4.2 9.5 15
|
|
|
+ 15 4.2 10.5
|
|
|
+
|
|
|
+ 575 60 Three 3.3 7.4 15 3.3 8.2 15
|
|
|
+
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 45 14.5-13.4 35.9 45
|
|
|
+
|
|
|
+5.0 460 60 Three 6.7 15.1 20 6.7 16.6 20
|
|
|
+
|
|
|
+ 575 60 Three 5.3 11.9 15 5.3 13.1 15
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+84 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE3XINV Energy Recovery Ventilator Standard ABBREVIATION
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ 33 7/8" Minimum OA: Outside Air intake
|
|
|
+ Service Area RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ Door INSTALLATION ORIENTATION
|
|
|
+ Swing Unit must be installed in orientation
|
|
|
+ 50 3/4" Overall shown.
|
|
|
+ 35 1/4" Case NOTE:
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ 45 5/8" Minimum DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ Service Area NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3. MIN. DUCT CLEARANCE
|
|
|
+ FROM DAMPER BLADES WHEN FULLY
|
|
|
+ OPENED TO BE 2". SMACNA RULES
|
|
|
+ APPLY.
|
|
|
+
|
|
|
+ TOP VIEW RA Inlet OA Inlet OA Damper
|
|
|
+ 36" X 14" 36" X 14" Location
|
|
|
+ RA Damper Duct Receiving Duct Receiving (Optional)
|
|
|
+ Location Flange Flange
|
|
|
+ (Optional)
|
|
|
+ 5" Damper 61 1/2" Overall
|
|
|
+ 1 5/8" Typ. Frames Typ. 61 1/2" Case
|
|
|
+
|
|
|
+ 46 5/8" Typ. RA OA
|
|
|
+ 9 7/8" Typ. E-Box
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 85 Disconnect Pressure Ports 62" Overall 58" Case
|
|
|
+ 25 5/8" Wiring (4) Typ.
|
|
|
+ Switch
|
|
|
+ EA
|
|
|
+ FA
|
|
|
+
|
|
|
+ 36 5/8" Typ. CL 5 3/4" Power In 4 1/4" Duct 4" 16" X 12"
|
|
|
+ CL 7 3/4" Wiring CL 2 5/8" Control In Flange Typ. Duct Receiving
|
|
|
+ (2) 7/8" Holes for Flange Typ.
|
|
|
+ LEFT VIEW
|
|
|
+ DMAAvroIaaRildawFbeLleinOla:gsWHshTEoCyw3pOnXieNInNd:FiVmUIGennUsitiRonDAdTirmaIwOienNgn. sion Wiring in Bottom RIGHT VIEW
|
|
|
+ Version: MAY18
|
|
|
+ of E-Box UNIT MOUNTING & APPLICATION
|
|
|
+ Must be mounted as shown. RA/EA airstream can
|
|
|
+ FRONT VIEW be switched with OA/FA airstream unless certain
|
|
|
+ options are selected.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 3XINV Energy Recovery Ventilator
|
|
|
+ Standard with Bypass Economizer
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS Options:
|
|
|
+ Onboard variable frequency drives (VFDs) -
|
|
|
+Download specification at: Ventilation Type:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer one or both airstreams
|
|
|
+AIRFLOW PERFORMANCE Shaft grounding ring on motors with VFDs
|
|
|
+ Typical Airflow Range: 750-3,300 CFM Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ AHRI 1060 Certified Core: Three L125-G5
|
|
|
+ enhanced, premium
|
|
|
+ Standard Features: Bypass economizer damper
|
|
|
+ TEFC Premium efficiency motors
|
|
|
+ Motor starters (see bypass DIM drawing) -
|
|
|
+ Non-fused disconnect dry-bulb temperature controls (standard),
|
|
|
+ 24 VAC transformer/relay package enthalpy controls (option)
|
|
|
+ Cross-core differential pressure ports Class 1 low leakage motorized isolation dampers -
|
|
|
+ OA, RA or both airstreams
|
|
|
+ Filters: Qty. 2, Factory mounted filter alarms -
|
|
|
+ Total qty. 6, MERV 8: 20" x 20" x 2" both airstreams
|
|
|
+ Double wall construction
|
|
|
+ Unit Dimensions & Weight: Exterior paint - white, custom colors
|
|
|
+ 50 3/4" L x 61 1/2" W x 62" H
|
|
|
+ 590-999 lbs., varies by option(s) Accessories:
|
|
|
+ Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Digital time clock - wall mount (TC7D-W),
|
|
|
+ 60" L x 90" W x 70" H
|
|
|
+ 1,094 lbs. in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ Motor(s):
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+ with adjustable sheaves (see table below)
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ Sheave External Static Pressure (in. w.g.)
|
|
|
+ Adj.
|
|
|
+Motor Blower Turns 0.00 0.25 0.50 0.75 1.00 1.25 1.50
|
|
|
+ HP RPM Open SCFM BHP SCFM BHP SCFM BHP
|
|
|
+ 2.0 2185 0.8 SCFM BHP SCFM BHP SCFM BHP SCFM BHP
|
|
|
+ 1195 4 2440 1.1
|
|
|
+ 3.0 1355 2 2700 1.5 2000 0.7 1725 0.5 1210 0.4 3 Cores (IOM)
|
|
|
+ 1476 0 2810 2.1 Thermal Performance Ratings G5 2015.2.xlsx
|
|
|
+ 5.0 1536 2.5 2985 2.5
|
|
|
+ 1632 1.5 3100 2.8 2270 0.9 2060 0.8 1715 0.6 1210 0.5
|
|
|
+ 1696 0.5 3160 3.0
|
|
|
+ 1728 0 3300 3.3 2550 1.3 2380 1.2 2150 1.0 1750 0.8 1300 0.6
|
|
|
+ 1749 2 1840 1.5 1420 1.1
|
|
|
+ 1801 1 2700 2.1 2560 1.9 2370 1.8 2140 1.6 2145 1.8 1855 1.6
|
|
|
+ 1853 0 2335 2.1 2065 1.9
|
|
|
+ 2880 2.4 2760 2.3 2590 2.2 2400 2.0 2425 2.3 2165 2.1
|
|
|
+ 2440 2.1 2200 1.8
|
|
|
+ 3000 2.7 2900 2.7 2735 2.5 2505 2.3 2585 2.8 2350 2.1
|
|
|
+ 2715 2.6 2500 2.4
|
|
|
+ 3055 2.9 2960 2.8 2800 2.6 2635 2.5
|
|
|
+
|
|
|
+ 3200 3.1 3020 2.8 2860 2.6 2660 2.3
|
|
|
+
|
|
|
+ 3300 3.4 3140 3.1 2980 2.8 2800 2.6
|
|
|
+
|
|
|
+ 3245 3.4 3090 3.1 2920 2.9
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone outside of core airflow limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+ 1000 1500 2000 2500 3000 3500
|
|
|
+ Max. Max. 500
|
|
|
+ 90%
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Overcurrent FLA Min. Cir. Overcurrent Effectiveness (%)
|
|
|
+ per motor Amps Protection per motor Amps Protection
|
|
|
+
|
|
|
+ Device Device
|
|
|
+
|
|
|
+2.0 120 60 Single 20.0 45.0 60 70%
|
|
|
+
|
|
|
+ 208-230 60 Single 10.8-10.0 24.3 35 6.6-5.8 16.3 30 50%
|
|
|
+
|
|
|
+2.0 208-230 60 Three 6.6-5.8 14.9 20 6.6-5.8 28.3 20 30%
|
|
|
+ 460 60 Three 2.9 6.5 15 At AHRI 1060 standard conditions.
|
|
|
+ 15 2.9 7.2 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ 575 60 Three 2.4 5.4 15 2.4 5.9 15
|
|
|
+
|
|
|
+ 208-230 60 Single 14.7-14 33.1 40 9.4-8.5 40.2 45
|
|
|
+
|
|
|
+3.0 208-230 60 Three 9.4-8.5 21.1 25 9.4-8.5 23.2 25
|
|
|
+ 460 60 Three 4.2 9.5 15
|
|
|
+ 15 4.2 10.5
|
|
|
+
|
|
|
+ 575 60 Three 3.3 7.4 15 3.3 8.2 15
|
|
|
+
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 45 14.5-13.4 35.9 45
|
|
|
+
|
|
|
+5.0 460 60 Three 6.7 15.1 20 6.7 16.6 20
|
|
|
+
|
|
|
+ 575 60 Three 5.3 11.9 15 5.3 13.1 15
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+86 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE3XINV Energy Recovery Ventilator Standard with Bypass Economizer
|
|
|
+
|
|
|
+ 4 1/4" ABBREVIATIONS
|
|
|
+ Duct EA: Exhaust Air to outside
|
|
|
+ Flange OA: Outside Air intake
|
|
|
+ Typ. RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ 34" Minimum 36" X 14" Bypass Duct Connection BP: Bypass Air Intake
|
|
|
+ Service Area (Direct Mount to Damper, By Others)
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ Door BP Unit must be installed in orientation
|
|
|
+ Swing shown.
|
|
|
+ 51 3/8" Overall 45 5/8" Minimum
|
|
|
+ 35 1/4" Case Service Area RA OA NOTE
|
|
|
+ Face Bypass 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ Damper Damper DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ FA EA
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ BYPASS AIRFLOW SCHEMATIC 3. MIN. DUCT CLEARANCE
|
|
|
+ FROM DAMPER BLADE WHEN FULLY
|
|
|
+ FRONT VIEW OPENED TO BE 2". SMACNA RULES
|
|
|
+ APPLY.
|
|
|
+
|
|
|
+ TOP VIEW 4. UNITS WITH BYPASS WILL REQUIRE
|
|
|
+ ADDITIONAL SPACE FOR THE
|
|
|
+ Isolation Damper CONNECTION OF THE BYPASS DUCT
|
|
|
+ (Optional) (BY OTHERS).
|
|
|
+ Acts as Face Damper
|
|
|
+ RA Inlet For Bypass Units 5. FOR INSTALLATION DETAILS, REFER
|
|
|
+ 36" X 14" TO I&O MANUAL SUPPLEMENT FOR
|
|
|
+ Duct Receiving Bypass BYPASS.
|
|
|
+ Location
|
|
|
+ Flange 5" Damper Pressure Ports OA Damper 62 3/8" Overall OA Inlet
|
|
|
+ Frames Typ. (4) Typ. Location 62" Case 36" X 14"
|
|
|
+ 1 5/8" (Optional) Duct
|
|
|
+ RA Receiving
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 87 E-Box OA Flange
|
|
|
+
|
|
|
+ Disconnect 1 3/4"
|
|
|
+ Switch
|
|
|
+ 16" X 12" BP 62" Overall
|
|
|
+ Duct FA EA 58" Case
|
|
|
+ Receiving 26"
|
|
|
+ Flange Typ. 46 5/8"
|
|
|
+ 46 5/8"
|
|
|
+ 9 7/8" Typ. CL 5 3/4" Power In 36" X 14" Bypass
|
|
|
+ 4" CL 2 5/8" Control In Damper Location
|
|
|
+ 25 5/8" Wiring (2) 7/8" Holes for (Optional)
|
|
|
+ 36 5/8" Typ. Wiring in Bottom 4 1/4" Typ. 5 1/4"
|
|
|
+ CL 8 1/4" Wiring of E-Box RIGHT VIEW
|
|
|
+ FRONT VIEW
|
|
|
+ LEFT VIEW
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+ MAoIRdFeLlO: HWEC3XOINNFVIG[BUyRpAaTIsOs]N
|
|
|
+ DArvaailwablienags sThoywpnein:dUimnenistioDn dimraweinng.sion Must be mounted as shown. Airstreams can not
|
|
|
+ Version: MAY18 be switched.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 3XRT Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+ROOFTOP UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Onboard variable frequency drives (VFDs) -
|
|
|
+
|
|
|
+ Typical Airflow Range: 750-3,300 CFM one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ AHRI 1060 Certified Core: Three L125-G5 Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ Standard Features:
|
|
|
+ TEFC Premium efficiency motors enhanced, premium
|
|
|
+ Motor starters Class 1 low leakage motorized isolation dampers -
|
|
|
+ Non-fused disconnect
|
|
|
+ 24 VAC transformer/relay package OA, RA or both airstreams
|
|
|
+ Cross-core differential pressure ports Qty. 2, Factory mounted filter alarms -
|
|
|
+
|
|
|
+ Filters: both airstreams
|
|
|
+ Total qty. 6, MERV 8: 20" x 20" x 2" Double wall construction
|
|
|
+ Exterior paint - white, custom colors
|
|
|
+ Unit Dimensions & Weight:
|
|
|
+ 94" L x 63 1/4" W x 44" H Accessories:
|
|
|
+ 656-972 lbs., varies by option(s) Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Roof curb - standard 14"
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Curb wind clip
|
|
|
+ 80" L x 70" W x 67" H Engineered combo curb for Carrier RTU
|
|
|
+ 1,067 lbs. Engineered combo curb for Trane RTU
|
|
|
+ Digital time clock - wall mount (TC7D-W),
|
|
|
+ Motor(s):
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ with adjustable sheaves (see table below)
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+AIRFLOW PERFORMANCE IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+Motor Blower Sheave External Static Pressure (in. w.g.)
|
|
|
+ HP RPM Adj.
|
|
|
+ Turns 0.00 0.25 0.50 0.75 1.00 1.25 1.50
|
|
|
+ 1207 Open SCFM BHP SCFM BHP SCFM BHP
|
|
|
+ SCFM BHP SCFM BHP SCFM BHP SCFM BHP
|
|
|
+ 4 2130 1.0
|
|
|
+ 1940 Th0e.8rmal P1e6r9f5orman0c.e6 Rating1s34G05 20150..42.xlsx 3 Cores (IOM)
|
|
|
+ 2210 1.2 2005 1.0 1725 0.8 1365 0.5
|
|
|
+2.0 1347 2 2380 1.4
|
|
|
+
|
|
|
+ 1488 0 2630 1.9 2470 1.6 2300 1.4 2100 1.2 1800 0.9 1435 0.7 820 0.4
|
|
|
+
|
|
|
+ 1533 3 2790 2.5 2660 2.3 2500 2.1 2290 1.8 2040 1.6 1765 1.3 1265 1.0
|
|
|
+
|
|
|
+3.0 1597 2 2905 2.8 2785 2.6 2630 2.4 2340 2.1 2200 1.9 1955 1.6 1640 1.3
|
|
|
+
|
|
|
+ 1661 0.5 2810 3.0 2760 2.7 2585 2.5 2365 2.2 2140 1.9 1890 1.6
|
|
|
+
|
|
|
+ 1692 0 2820 2.9 2665 2.7 2450 2.4 2220 2.1 1980 1.8
|
|
|
+
|
|
|
+ 1686 3 3110 3.5 3000 3.2 2890 3.0 2730 2.7 2520 2.4 2295 2.1 2000 1.8
|
|
|
+
|
|
|
+5.0 1764 1.5 3255 4.0 3150 3.7 3045 3.5 2905 3.2 2720 2.9 2520 2.5 2270 2.2
|
|
|
+
|
|
|
+ 1843 0 3300 4.2 3200 4.0 3075 3.7 2910 3.4 2715 3.0 2500 2.7
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits. Operation in this zone outside of core airflow limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+ 1000 1500 2000 2500 3000 3500
|
|
|
+ FLA Min. Cir. Max. FLA Min. Cir. Max. 500
|
|
|
+HP Volts HZ Phase per motor Amps Overcurrent per motor Amps Overcurrent Effectiveness (%) 90%
|
|
|
+ Protection Protection
|
|
|
+
|
|
|
+ Device Device
|
|
|
+
|
|
|
+2.0 120 60 Single 20.0 45.0 60 70%
|
|
|
+
|
|
|
+ 208-230 60 Single 10.8-10.0 24.3 35 6.6-5.8 28.3 30 50%
|
|
|
+ 20
|
|
|
+2.0 208-230 60 Three 6.6-5.8 14.9 15 6.6-5.8 16.3 20
|
|
|
+ 460 60 Three 2.9 6.5 15
|
|
|
+ 2.9 7.2 15
|
|
|
+ 40
|
|
|
+ 575 60 Three 2.4 5.4 25 2.4 5.9 15 30%
|
|
|
+ 15 At AHRI 1060 standard conditions.
|
|
|
+ 208-230 60 Single 14.7-14 33.1 15 9.4-8.5 40.2 45 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+3.0 208-230 60 Three 9.4-8.5 21.1 45 9.4-8.5 23.2 25
|
|
|
+ 460 60 Three 4.2 9.5 20
|
|
|
+ 15 4.24 10.5 15
|
|
|
+
|
|
|
+ 575 60 Three 3.3 7.4 3.3 8.2 15
|
|
|
+
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 14.5-13.4 35.9 45
|
|
|
+
|
|
|
+5.0 460 60 Three 6.7 15.1 6.7 16.6 20
|
|
|
+
|
|
|
+ 575 60 Three 5.3 11.9 5.3 13.1 15
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+88 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE3XRT (RTV/RTR) Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ 26 1/8" RA Damper ABBREVIATIONS
|
|
|
+ Location EA: Exhaust Air to outside
|
|
|
+ RA (Optional) CURB 3X OA: Outside Air intake
|
|
|
+ 10" X 42" (Recessed 3/4") RA: Room Air to be exhausted
|
|
|
+ Opening 45 1/4" FA: Fresh Air to inside
|
|
|
+ 35 3/8" RA RTV: Rooftop Vertical RA & FA
|
|
|
+ Minimum A RTR: Rooftop Vertical RA Only
|
|
|
+ Service Area
|
|
|
+ 13 1/4" INSTALLATION ORIENTATION
|
|
|
+ Door Unit must be installed in orientation
|
|
|
+ Swing shown.
|
|
|
+
|
|
|
+ NOTE:
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ 57 3/8" Case 67 1/2" Minimum NEAREST EIGHTH OF AN INCH.
|
|
|
+ 47 3/8" Service Area 50 3/8" I.D. A 54 1/8" O.D.
|
|
|
+ 13 3/4" 3 3/4"
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ 14"TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ Door FA CURB CROSS-SECTION A-A (TYP.)
|
|
|
+ Swing
|
|
|
+ 14 1/4"
|
|
|
+ FA (RTV) 53 1/8" I.D. 4 5/8" 1 1/2" X 1/4" 1 7/8"
|
|
|
+ 12" X 6 7/8" 56 7/8" O.D. Neoprene Gasket
|
|
|
+ 1 1/T8Y"P 10 1/4"
|
|
|
+ Opening TOP VIEW
|
|
|
+ 45" 3/4" X 3 1/2"
|
|
|
+ Wooden Nailer
|
|
|
+ 62 1/4" Case
|
|
|
+ 3"
|
|
|
+ TOP VIEW
|
|
|
+
|
|
|
+ TY2P1/8" SECTION A-A
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 89 FA (RTR) EA Outlet 93 7/8" Overall OA Inlet 63 1/8"
|
|
|
+ 12" X 12" 55 1/4" Lift Lugs Damper Overall
|
|
|
+ Duct Receiving E-Box Location
|
|
|
+ Flange 19 5/8" (Optional) 60 1/4" Lift Lugs
|
|
|
+
|
|
|
+ 44" 12 3/4" Wiring EA OA
|
|
|
+ Overall
|
|
|
+
|
|
|
+ 41"
|
|
|
+ Case
|
|
|
+
|
|
|
+ FA RTR
|
|
|
+ ONLY
|
|
|
+
|
|
|
+ 38 3/4" 5 1/4" Disconnect FA Pressure Ports 60 1/8"
|
|
|
+ 55 3/8" Switch (4) Typ.
|
|
|
+ Wiring
|
|
|
+ CL 5 3/4" Power In RTV RA
|
|
|
+ LEFT VIEW CL 2 5/8" Control In ONLY
|
|
|
+
|
|
|
+ MDroadwAAveIaiRnill:aFgbHLleOTEays3WpsXheoCRw:OnTU:VNn/FiRtIGTDRUiRmAeTnIOsiNon (2) 7/8" Holes 56 7/8"
|
|
|
+ Version: MAY18 for wiring in bottom
|
|
|
+ HERT except 6x 8x,oLEfRET -Box FRONT VIEW
|
|
|
+ HERT except 6x 8x, LERT
|
|
|
+
|
|
|
+ RTV RTR RIGHT VIEW
|
|
|
+
|
|
|
+ EA OA EA OA UNIT MOUNTING & APPLICATION
|
|
|
+ Must be mounted as shown. Airstreams can not
|
|
|
+ FA be switched.
|
|
|
+
|
|
|
+ FA RA RA
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+ 2 1/T8Y"P
|
|
|
+90 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE3XRT (RTH/RTF) Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+TY1P1/8" ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ CURB 3X OA: Outside Air intake
|
|
|
+ RA: Room Air to be exhausted
|
|
|
+ 45 1/4" FA: Fresh Air to inside
|
|
|
+ RA RTF: Rooftop Vertical FA Only
|
|
|
+ A RTH: Rooftop Horizontal RA & FA
|
|
|
+
|
|
|
+ 35 3/8" 13 1/4" FA INSTALLATION ORIENTATION
|
|
|
+ Minimum Unit must be installed in orientation
|
|
|
+ Service Area 14 1/4" shown.
|
|
|
+ 53 1/8" I.D.
|
|
|
+ Door 56 7/8" O.D. NOTE:
|
|
|
+ Swing 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ TOP VIEW DIMENSIONS ARE ROUNDED TO THE
|
|
|
+57 3/8" Case Door 67 1/2" Minimum NEAREST EIGHTH OF AN INCH.
|
|
|
+ 13 3/4" Swing Service Area 50 3/8" I.D. A 54 1/8" O.D.
|
|
|
+ 3 3/4"
|
|
|
+ 45" 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ 14"TO CHANGE WITHOUT NOTICE.
|
|
|
+ FA (RTF) 6"
|
|
|
+ 12" X 6 7/8" CURB CROSS-SECTION A-A (TYP.)
|
|
|
+
|
|
|
+ Opening 4 5/8" 1 1/2" X 1/4" 1 7/8"
|
|
|
+ 62 3/8" Case Neoprene Gasket
|
|
|
+ 10 1/4"
|
|
|
+ TOP VIEW 3/4" X 3 1/2"
|
|
|
+ Wooden Nailer
|
|
|
+
|
|
|
+ 3"
|
|
|
+
|
|
|
+ SECTION A-A
|
|
|
+
|
|
|
+ FA (RTH) EA Outlet 93 7/8" Overall OA Inlet 63 1/8"
|
|
|
+ 12" X 12" 55 1/4" Lift Lugs Damper Overall
|
|
|
+ Duct Receiving E-Box Location
|
|
|
+ Flange 19 5/8" (Optional) 60 1/4" Lift Lugs
|
|
|
+
|
|
|
+44" 12 3/4" EA OA
|
|
|
+ Overall Wiring
|
|
|
+
|
|
|
+ 41" RA
|
|
|
+ Case
|
|
|
+ Pressure Ports
|
|
|
+ FA RTH (4) Typ.
|
|
|
+ ONLY 5" Damper
|
|
|
+ Frames Typ.
|
|
|
+ 38 3/4" Disconnect5 1/4" FA RA 12 1/4"
|
|
|
+ 55 3/8" Switch 36" X 14" 60 1/8"
|
|
|
+ Wiring RTF Duct Receiving
|
|
|
+ CL 5 3/4" Power In ONLY Flange RA Damper
|
|
|
+ LEFT VIEW CL 2 5/8" Control In Location
|
|
|
+ AIRFLOW CONFIGURATION 56 7/8" (Optional)
|
|
|
+ (2) 7/8" Holes
|
|
|
+ModAveaill:abHleEas3sXhoRwnT:H/RTF for wiring in bottom FRONT VIEW RIGHT VIEW
|
|
|
+Drawing Type: Unit Dimension HERT except 6x 8x, LEoRTf E-Box HERTexcept 6x 8x, LERT
|
|
|
+Version: MAY18
|
|
|
+ RTH RTF UNIT MOUNTING & APPLICATION
|
|
|
+
|
|
|
+ EA OA EA OA Must be mounted as shown. Airstreams can not
|
|
|
+ be switched.
|
|
|
+ FA RA RA
|
|
|
+
|
|
|
+ FA
|
|
|
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 91
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 3XRTC Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+ROOFTOP UNIT SPECIFICATIONS
|
|
|
+Direct Connect
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Onboard variable frequency drives (VFDs) -
|
|
|
+
|
|
|
+ Typical Airflow Range: 1,100-2,400 CFM one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ AHRI 1060 Certified Core: Three L125-G5 Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ Standard Features:
|
|
|
+ TEFC Premium efficiency motors enhanced, premium
|
|
|
+ Motor starters Qty. 2, Factory mounted filter alarms -
|
|
|
+ Non-fused disconnect
|
|
|
+ 24 VAC transformer/relay package both airstreams
|
|
|
+ Cross-core differential pressure ports Double wall construction
|
|
|
+ Exterior paint - white, custom colors
|
|
|
+ Filters:
|
|
|
+ Total qty. 5, MERV 8: (3) 20" x 20" x 2" and Accessories:
|
|
|
+ Filters - MERV 13, 2" (shipped loose)
|
|
|
+ (2) 16" x 25" x 2" RTC transition kit - for vertical RTU, for horizontal RTU
|
|
|
+ Rooftop RTC transition paint - white, custom colors
|
|
|
+ Unit Dimensions & Weight: Digital time clock - wall mount (TC7D-W),
|
|
|
+ 81 1/4" L x 63 1/2" W x 48 1/4" H
|
|
|
+ 713-1,084 lbs., varies by option(s) in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet):
|
|
|
+ 80" L x 90" W x 80" H wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ 1,225 lbs. IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ Motor(s): duct mount (IAQ-D)
|
|
|
+ Qty. 2, 3.0 HP ea., Belt drive blower/standard motor Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ packages with adjustable sheaves ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+
|
|
|
+ Note: Electric Duct Heater and Indirect Gas-Fired Duct Furnace are not available on RTC units.
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+ Tie-In Directly to Rooftop A/C Unit* Unit Ducted Indendently*
|
|
|
+
|
|
|
+ Blower RPM Sheave Adj. Static Pressure in Adjacent Air Handler External Static Pressure (Inches Water Column)
|
|
|
+ Nominal Turns Open (Inches Water Column)
|
|
|
+
|
|
|
+ -0.75 -0.5 -0.25 0.0 +0.25 +0.5 +0.75
|
|
|
+
|
|
|
+ CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
|
|
|
+
|
|
|
+ 1510 0 2010 2.7 2010 2.7
|
|
|
+
|
|
|
+ 1465 1 1920 2.3 2130 2.9 2130 2.9 1920 2.3
|
|
|
+
|
|
|
+ 1420 2 1830 1.9 2035 2.5 2240 3.0 2240 3.0 2035 2.5 1830 1.9
|
|
|
+
|
|
|
+Exhaust Air 1375 3 1750 1.1 1945 1.9 2140 2.6 2400 2.7 2140 2.6 1945 1.9 1750 1.1
|
|
|
+
|
|
|
+ 1330 4 1690 1.0 Th1e8r6m0 al Pe1r.5forma2n0c3e0Ratin1g.9s G5 22031350.2.xls2x.6 2030 1.9 18360Cores1.(5IOM) 1690 1.0
|
|
|
+ 1510 0.9 1725 1.0 1940 1.1 2250 2.1 1940 1.1 1725 1.0 1510 0.9
|
|
|
+ 1285 5
|
|
|
+
|
|
|
+ 1240 6 1320 0.8 1590 0.5 1860 0.3 2165 1.5 1860 0.3 1590 0.5 1320 0.8
|
|
|
+
|
|
|
+ 1825 0 2250 2.9 2100 2.5 1865 2.3 1630 2.1
|
|
|
+
|
|
|
+ 1770 1 2525 3.0 2338 2.7 2195 2.6 2025 2.3 1785 2.1 1545 1.8
|
|
|
+
|
|
|
+ 1715 2 2605 2.7 2430 2.6 2255 2.4 2120 2.3 1960 2.0 1700 1.2 1440 1.4
|
|
|
+
|
|
|
+Fresh Air 1660 3 2515 2.4 2345 2.2 2175 1.9 2050 1.8 1900 1.6 1620 0.6 1340 1.0
|
|
|
+
|
|
|
+ 1605 4 2430 2.2 2270 1.8 2110 1.3 1980 1.3 1830 1.3 1560 0.4 1290 0.5
|
|
|
+
|
|
|
+ 1550 5 2355 1.2 2185 1.1 2015 1.0 1900 0.6 1765 0.4 1540 0.3 1200 0.4
|
|
|
+
|
|
|
+ 1495 6 2230 0.8 2090 0.7 1950 0.5 1840 0.4 1730 0.3 1500 0.2 1100 0.2
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+* See page 38 for installation details. CORE PERFORMANCE
|
|
|
+
|
|
|
+ELECTRICAL DATA Optional Factory Installed Airflow (CFM)
|
|
|
+ Standard Electrical Specifications VFD Electrical Specifications
|
|
|
+ 1000 1500 2000 2500 3000 3500
|
|
|
+ 500
|
|
|
+ Max. Max. Effectiveness (%) 90%
|
|
|
+ Overcurrent Overcurrent
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Protection FLA Min. Cir. Protection
|
|
|
+ per motor Amps per motor Amps
|
|
|
+ Device Device 70%
|
|
|
+
|
|
|
+ 208-230 60 Single 14.7-14 33.1 40 9.4-8.5 40.2 45 50%
|
|
|
+
|
|
|
+3.0 208-230 60 Three 9.4-8.5 21.1 25 9.4-8.5 23.2 25 30%
|
|
|
+ 460 60 Three 4.2 9.5 15 At AHRI 1060 standard conditions.
|
|
|
+ 15 4.24 10.5 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ 575 60 Three 3.3 7.4 15 3.3 8.2 15
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+92 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE3XRTC Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ 33 7/8" Minimum ABBREVIATIONS
|
|
|
+ Service Area EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ Door 67 5/8" Minimum RA: Room Air to be exhausted
|
|
|
+ Swing Service Area FA: Fresh Air to inside
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ Unit must be installed in orientation
|
|
|
+ shown.
|
|
|
+ NOTE:
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ Door
|
|
|
+ Swing
|
|
|
+
|
|
|
+ 2 1T/y8p".Ty1p1./8"
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 93
|
|
|
+ TOP VIEW E-Box 81 1/4" Overall 11 1/4" Typ. 63 1/2" Overall
|
|
|
+ 60 1/4" Case
|
|
|
+ EA 57 1/8" Case
|
|
|
+ 59 3/8" 54 1/2" 29" Typ.
|
|
|
+ Lifting Lugs 4 3/8" Typ.
|
|
|
+ OA Lifting Lugs
|
|
|
+ RIGHT VIEW
|
|
|
+ CL 5 3/4" Wiring 5" Wiring EA FA 45 1/4" Case
|
|
|
+ Disconnect RA UNIT MOUNTING & APPLICATION48 1/8" Overall
|
|
|
+ LEFT VIEW 25 5/8" Must be mounted as shown. Airstreams can not
|
|
|
+MDAAvIarRoialaFdbwLleeOianls:WgsHhoCTEwy3OnpXiNneRdFi:TmIGCUenUnsiRiotnADdTraiImwOinNeg.nsion Switch Pressure Ports be switched.
|
|
|
+Version: MAY18 (4) Typ. 6 5/8"
|
|
|
+ OA
|
|
|
+ FRONT VIEW
|
|
|
+ CL 5 5/8" Power In
|
|
|
+ CL 1 1/4" Control In
|
|
|
+ (2) 7/8" Holes for
|
|
|
+ Wiring in Bottom
|
|
|
+ of E-Box
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 4XINH Energy Recovery Ventilator
|
|
|
+ Standarrdd & Bypass Economizer Option
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Onboard variable frequency drives (VFDs) -
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE Typical Airflow Range: 1,000-4,400 CFM one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ AHRI 1060 Certified Core: Four L125-G5 Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ Standard Features:
|
|
|
+ TEFC Premium efficiency motors enhanced, premium
|
|
|
+ Motor starters Bypass economizer damper
|
|
|
+ Non-fused disconnect
|
|
|
+ 24 VAC transformer/relay package (see bypass DIM drawing) -
|
|
|
+ Cross-core differential pressure ports dry-bulb temperature controls (standard),
|
|
|
+ enthalpy controls (option)
|
|
|
+ Filters: Class 1 low leakage motorized isolation dampers -
|
|
|
+ Total qty. 8, MERV 8: 20" x 20" x 2" OA, RA or both airstreams
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+ Unit Dimensions & Weight: both airstreams
|
|
|
+ 72 3/4" L x 82 3/4" W x 44" H Double wall construction
|
|
|
+ 723-1,092 lbs., varies by option(s) Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Accessories:
|
|
|
+ 80" L x 90" W x 50" H Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 1,228 lbs. Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ Motor(s): in exterior enclosure (TC7D-E)
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ with adjustable sheaves (see table below) wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ Blower Sheave External Static Pressure (in. w.g.)
|
|
|
+ RPM Adj.
|
|
|
+Motor HP Turns 0.00 0.25 0.50 0.75 1.00 1.25 1.50
|
|
|
+ Open SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP
|
|
|
+ 3215 1.5
|
|
|
+ 1187 4 3505 2.0 2990 1.4 2535 1.2 2120 0.9 1360 0.7 1180 4 Cor0e.6s (IOM)
|
|
|
+ 2.5 3300 Th1e.9rmal P3e0r0f0orman1ce.7Rating2s61G05 20151..42.xlsx 2060 1790 1.1
|
|
|
+ 1290 1.5 3945 2.9 1.1 2400 1.6 1730 1.2
|
|
|
+ 2 0 2310 1.5 1670 1.2
|
|
|
+ 4 4335 3.8 3220 2.0 2885 1.8 2415 1.4 2695 2.0 2165 1.6
|
|
|
+ 1358 3 3050 2.4 2580 2.1
|
|
|
+ 2 3380 3.0 2930 2.5
|
|
|
+ 1462 1 2900 2.0
|
|
|
+ 0 3300 3.0
|
|
|
+ 1448 4 3765 2.8 3515 2.4 3200 2.1 2845 1.9 3050 2.5 2580 2.1
|
|
|
+ 2 3510 3.2 3100 2.8
|
|
|
+ 1520 0 3740 2.9 3475 2.6 3145 2.3 3900 4.0 3600 3.7
|
|
|
+
|
|
|
+ 3 1591 3415 2.8
|
|
|
+
|
|
|
+ 1663
|
|
|
+
|
|
|
+ 1735
|
|
|
+
|
|
|
+ 1591 4185 4.0 3965 3.4 3710 3.1 3410 2.8
|
|
|
+ 4280 4.1 4060 3.9 3800 3.5
|
|
|
+ 5 1696 4395 4.7 4165 4.3
|
|
|
+
|
|
|
+ 1800
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits. Operation in this zone outside of core airflow limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+ Max. Max. 1000 2000 3000 4000
|
|
|
+ 90%
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Overcurrent FLA Min. Cir. Overcurrent Effectiveness (%)
|
|
|
+ per motor Amps Protection per motor Amps Protection
|
|
|
+
|
|
|
+ Device Device
|
|
|
+
|
|
|
+2.0 120 60 Single 20.0 45.0 60 70%
|
|
|
+
|
|
|
+ 208-230 60 Single 10.8-10.0 24.3 35 6.6-5.8 28.3 30 50%
|
|
|
+
|
|
|
+2.0 208-230 60 Three 6.6-5.8 14.9 20 6.6-5.8 16.3 20 30%
|
|
|
+ 460 60 Three 2.9 6.5 15 At AHRI 1060 standard conditions.
|
|
|
+ 15 2.9 7.2 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ 575 60 Three 2.4 5.4 15 2.4 5.9 15
|
|
|
+
|
|
|
+ 208-230 60 Single 14.7-14 33.1 40 9.4-8.5 40.2 45
|
|
|
+
|
|
|
+3.0 208-230 60 Three 9.4-8.5 21.1 25 9.4-8.5 23.2 25
|
|
|
+ 460 60 Three 4.2 9.5 15
|
|
|
+ 15 4.2 10.5
|
|
|
+
|
|
|
+ 575 60 Three 3.3 7.4 15 3.3 8.2 15
|
|
|
+
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 45 14.5-13.4 35.9 45
|
|
|
+
|
|
|
+5.0 460 60 Three 6.7 15.1 20 6.7 16.6 20
|
|
|
+
|
|
|
+ 575 60 Three 5.3 11.9 15 5.3 13.1 15
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+94 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE4XINH Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ 72 3/4" Overall ABBREVIATIONS
|
|
|
+ 57 3/8" Case EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ 82" Case RA: Room Air to be exhausted
|
|
|
+ 82 3/4" Overall FA: Fresh Air to inside
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ Unit must be installed in orientation
|
|
|
+ shown.
|
|
|
+ NOTE
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3. MIN. DUCT CLEARANCE
|
|
|
+ FROM DAMPER BLADES WHEN FULLY
|
|
|
+ OPENED TO BE 2". SMACNA RULES
|
|
|
+ APPLY.
|
|
|
+
|
|
|
+ 38 7/8" Minimum Door Door
|
|
|
+ Service Area Swing Swing
|
|
|
+ 2 1/T8y"p.
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 95 67 3/8" Minimum Ty1p.1/8"
|
|
|
+ Service Area
|
|
|
+ 34" X 12" 10 1/4" 5" Damper OA Inlet OA Damper
|
|
|
+ Duct Receiving 4 1/4" TOP VIEW Frames Typ. 42" X 14" Location
|
|
|
+ Flange Typ. Duct Receiving (Optional)
|
|
|
+ Duct Flange 55 7/8" Lifting Lugs OA Flange
|
|
|
+ E-Box Typ. 19 1/4" Typ.
|
|
|
+37 3/8" Typ.
|
|
|
+ EA
|
|
|
+ 41"Case RA 44"Overall 6"
|
|
|
+ FA 24 3/4"
|
|
|
+ CL 76" Wiring 56 7/8" Pressure RA Inlet
|
|
|
+ 79 3/4" Disconnect Ports (4) Typ. 42" X 14"
|
|
|
+ Switch Duct Receiving
|
|
|
+ LEFT VIEW Flange
|
|
|
+MAoIRdFeLlO: W HEC4XOINNFHIGURATION 4 1/2" CL 2 5/8" Control In (2) 7/8" Holes 3 3/4" RA Damper
|
|
|
+DArvaailwablienags shToywpn ein:diUmennistioDn dimraweinng.sion 21 3/8" CL 5 3/4" Power In for wiring in Location
|
|
|
+Version: MAY18 bottom of E-Box (Optional)
|
|
|
+
|
|
|
+ FRONT VIEW RIGHT VIEW
|
|
|
+
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+
|
|
|
+ Must be mounted as shown. RA/EA airstream can
|
|
|
+ be switched with OA/FA airstream unless certain
|
|
|
+ options are selected.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 4XINH Energy Recovery Ventilator
|
|
|
+ Standard with Bypass Economizer
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Onboard variable frequency drives (VFDs) -
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE Typical Airflow Range: 1,000-4,400 CFM one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ AHRI 1060 Certified Core: Four L125-G5 Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ Standard Features:
|
|
|
+ TEFC Premium efficiency motors enhanced, premium
|
|
|
+ Motor starters Bypass economizer damper
|
|
|
+ Non-fused disconnect
|
|
|
+ 24 VAC transformer/relay package (see bypass DIM drawing) -
|
|
|
+ Cross-core differential pressure ports dry-bulb temperature controls (standard),
|
|
|
+ enthalpy controls (option)
|
|
|
+ Filters: Class 1 low leakage motorized isolation dampers -
|
|
|
+ Total qty. 8, MERV 8: 20" x 20" x 2" OA, RA or both airstreams
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+ Unit Dimensions & Weight: both airstreams
|
|
|
+ 72 3/4" L x 82 3/4" W x 44" H Double wall construction
|
|
|
+ 723-1,092 lbs., varies by option(s) Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Accessories:
|
|
|
+ 80" L x 90" W x 50" H Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 1,228 lbs. Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ Motor(s): in exterior enclosure (TC7D-E)
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ with adjustable sheaves (see table below) wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ Blower Sheave External Static Pressure (in. w.g.)
|
|
|
+ RPM Adj.
|
|
|
+Motor HP Turns 0.00 0.25 0.50 0.75 1.00 1.25 1.50
|
|
|
+ Open SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP
|
|
|
+ 3215 1.5
|
|
|
+ 1187 4 3505 2.0 2990 1.4 2535 1.2 2120 0.9 1360 0.7 1180 4 Cor0e.6s (IOM)
|
|
|
+ 2.5 3300 Th1e.9rmal P3e0r0f0orman1ce.7Rating2s61G05 20151..42.xlsx 2060 1790 1.1
|
|
|
+ 1290 1.5 3945 2.9 1.1 2400 1.6 1730 1.2
|
|
|
+ 2 0 2310 1.5 1670 1.2
|
|
|
+ 4 4335 3.8 3220 2.0 2885 1.8 2415 1.4 2695 2.0 2165 1.6
|
|
|
+ 1358 3 3050 2.4 2580 2.1
|
|
|
+ 2 3380 3.0 2930 2.5
|
|
|
+ 1462 1 2900 2.0
|
|
|
+ 0 3300 3.0
|
|
|
+ 1448 4 3765 2.8 3515 2.4 3200 2.1 2845 1.9 3050 2.5 2580 2.1
|
|
|
+ 2 3510 3.2 3100 2.8
|
|
|
+ 1520 0 3740 2.9 3475 2.6 3145 2.3 3900 4.0 3600 3.7
|
|
|
+
|
|
|
+ 3 1591 3415 2.8
|
|
|
+
|
|
|
+ 1663
|
|
|
+
|
|
|
+ 1735
|
|
|
+
|
|
|
+ 1591 4185 4.0 3965 3.4 3710 3.1 3410 2.8
|
|
|
+ 4280 4.1 4060 3.9 3800 3.5
|
|
|
+ 5 1696 4395 4.7 4165 4.3
|
|
|
+
|
|
|
+ 1800
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits. Operation in this zone outside of core airflow limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+ Max. Max. 1000 2000 3000 4000
|
|
|
+ 90%
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Overcurrent FLA Min. Cir. Overcurrent Effectiveness (%)
|
|
|
+ per motor Amps Protection per motor Amps Protection
|
|
|
+
|
|
|
+ Device Device
|
|
|
+
|
|
|
+2.0 120 60 Single 20.0 45.0 60 70%
|
|
|
+
|
|
|
+ 208-230 60 Single 10.8-10.0 24.3 35 6.6-5.8 28.3 30 50%
|
|
|
+
|
|
|
+2.0 208-230 60 Three 6.6-5.8 14.9 20 6.6-5.8 16.3 20 30%
|
|
|
+ 460 60 Three 2.9 6.5 15 At AHRI 1060 standard conditions.
|
|
|
+ 15 2.9 7.2 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ 575 60 Three 2.4 5.4 15 2.4 5.9 15
|
|
|
+
|
|
|
+ 208-230 60 Single 14.7-14 33.1 40 9.4-8.5 40.2 45
|
|
|
+
|
|
|
+3.0 208-230 60 Three 9.4-8.5 21.1 25 9.4-8.5 23.2 25
|
|
|
+ 460 60 Three 4.2 9.5 15
|
|
|
+ 15 4.2 10.5
|
|
|
+
|
|
|
+ 575 60 Three 3.3 7.4 15 3.3 8.2 15
|
|
|
+
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 45 14.5-13.4 35.9 45
|
|
|
+
|
|
|
+5.0 460 60 Three 6.7 15.1 20 6.7 16.6 20
|
|
|
+
|
|
|
+ 575 60 Three 5.3 11.9 15 5.3 13.1 15
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+96 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE4XINH Energy Recovery Ventilator Standard with Bypass Economizer
|
|
|
+
|
|
|
+ 34" X 16" Bypass Duct Connection 4 1/8" Duct 72 3/4" Overall 5" Damper ABBREVIATIONS
|
|
|
+ (Direct Mount to Damper, By Others) Flange Typ. 57 3/8" Case Frames Typ. EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ Bypass BP 5 1/8" 48 7/8" RA: Room Air to be exhausted
|
|
|
+ Damper 82" Case FA: Fresh Air to inside
|
|
|
+ OA 34" X 16" Bypass BP: Bypass Air Intake
|
|
|
+EA Damper Location 82 7/8" Overall INSTALLATION ORIENTATION
|
|
|
+ (Optional) Unit must be installed in orientation
|
|
|
+FA RA shown.
|
|
|
+ NOTE
|
|
|
+ Face Damper 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+BYPASS AIRFLOW SCHEMATIC NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ FRONT VIEW TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3. MIN. DUCT CLEARANCE
|
|
|
+ 2 1/8"38 7/8" MinimumDoorDoor FROM DAMPER BLADE WHEN FULLY
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 97 Service Area Swing Swing OPENED TO BE 2". SMACNA RULES
|
|
|
+ APPLY.
|
|
|
+ 4. UNITS WITH BYPASS WILL REQUIRE
|
|
|
+ ADDITIONAL SPACE FOR THE
|
|
|
+ CONNECTION OF THE BYPASS DUCT
|
|
|
+ (BY OTHERS).
|
|
|
+ 5. FOR INSTALLATION DETAILS, REFER
|
|
|
+ TO I&O MANUAL SUPPLEMENT FOR
|
|
|
+ BYPASS.
|
|
|
+
|
|
|
+ BP 34" X 12" 67 3/8" Minimum 1 1/8" OA Damper OA Inlet
|
|
|
+ Duct Receiving Service Area 47 3/8" OverallLocation 42" X 14"
|
|
|
+37 3/8" Typ. Flange Typ. 5 7/8"(Optional) Duct
|
|
|
+ TOP VIEW Receiving
|
|
|
+ 79 1/8" Lifting Lugs Flange
|
|
|
+ 54 1/2" Lifting Lugs
|
|
|
+ Pressure
|
|
|
+ 10 1/4" Ports (4) Typ.
|
|
|
+ E-Box
|
|
|
+ OA
|
|
|
+ EA
|
|
|
+ 41" Case RA 24 5/8"
|
|
|
+ FA
|
|
|
+ CL 76" Wiring 4 1/2" 56 7/8" RA Inlet 19 1/8"
|
|
|
+ 79 3/4" 21 3/8" Disconnect
|
|
|
+ Switch
|
|
|
+ LEFT VIEW
|
|
|
+MAIoRdFLeOl:WHEC4OXNINFHIG[UBRyApTaIOssN] CL 2 5/8" Control In (2) 7/8" Holes Isolation Damper 42" X 14" Typ.
|
|
|
+DAvraailawbleinasgshTowynpined:imUennsiitonDdrimawiengn. sion (Optional)
|
|
|
+Version: MAY18 CL 5 3/4" Power In for wiring in Duct Receiving
|
|
|
+ bottom of E-Box Acts as Face Damper
|
|
|
+ For Bypass Units Flange
|
|
|
+
|
|
|
+ FRONT VIEW RIGHT VIEW
|
|
|
+
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+
|
|
|
+ Must be mounted as shown. Airstreams can not
|
|
|
+ be switched.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 4XINV Energy Recovery Ventilator
|
|
|
+ Standarrdd & Bypass Economizer Option
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Onboard variable frequency drives (VFDs) -
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE Typical Airflow Range: 1,000-4,400 CFM one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ AHRI 1060 Certified Core: Four L125-G5 Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ Standard Features:
|
|
|
+ TEFC Premium efficiency motors enhanced, premium
|
|
|
+ Motor starters Bypass economizer damper
|
|
|
+ Non-fused disconnect
|
|
|
+ 24 VAC transformer/relay package (see bypass DIM drawing) -
|
|
|
+ Cross-core differential pressure ports dry-bulb temperature controls (standard),
|
|
|
+ enthalpy controls (option)
|
|
|
+ Filters: Class 1 low leakage motorized isolation dampers -
|
|
|
+ Total qty. 8, MERV 8: 20" x 20" x 2" OA, RA or both airstreams
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+ Unit Dimensions & Weight: both airstreams
|
|
|
+ 50 3/4" L x 81 1/2" W x 62" H Double wall construction
|
|
|
+ 753-1,196 lbs., varies by option(s) Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Accessories:
|
|
|
+ 60" L x 90" W x 70" H Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 1,332 lbs. Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ Motor(s): in exterior enclosure (TC7D-E)
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ with adjustable sheaves (see table below) wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+Motor Blower Sheave External Static Pressure (in. w.g.)
|
|
|
+ HP RPM Adj.
|
|
|
+ 2.0 Turns 0.00 0.25 0.50 0.75 1.00 1.25 1.50
|
|
|
+ 1191 Open SCFM BHP
|
|
|
+ 3.0 1329 3330 1.4 SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP
|
|
|
+ 1432 4 3715 1.9
|
|
|
+ 5.0 1466 2 4000 2.4 3015 Th1e.2rmal P2e6r9fo0rmanc1e.0Rating1s91G55 20150.28.xlsx 1085 0.6 4 Cores (IOM)
|
|
|
+ 1462 0.5
|
|
|
+ 1503 0 4060 2.6 3440 1.7 3100 1.5 2485 1.3 2000 1.0 1200 0.8
|
|
|
+ 1586 3 4175 2.8
|
|
|
+ 1668 2.5 3740 2.2 3480 2.0 3050 1.7 2490 1.5 1900 1.2 1100 0.9
|
|
|
+ 1710 1.5 4393 3.9
|
|
|
+ 1627 0.5 3200 1.9 2650 1.6 2120 1.3 1385 1.1
|
|
|
+ 1731 0
|
|
|
+ 1836 4 3810 2.4 3550 2.1 3180 1.9 2645 1.6 2075 1.3 1345 1.0
|
|
|
+ 2
|
|
|
+ 0 3940 2.6 3700 2.4 3340 2.1 2885 1.7 2300 1.5 1600 1.2
|
|
|
+
|
|
|
+ 3950 2.8 3640 2.5 3250 2.3 2745 2.0 2170 1.7
|
|
|
+
|
|
|
+ 3900 3.0 3600 2.7 3155 2.4 2640 2.1
|
|
|
+
|
|
|
+ 3750 3.0 3350 2.7 2975 2.4
|
|
|
+
|
|
|
+ 4210 3.7 4050 3.6 3800 3.3 3490 3.1 3020 2.7 2385 2.4
|
|
|
+
|
|
|
+ 4350 4.3 4150 4.1 3895 3.8 3515 3.5 3055 3.2
|
|
|
+
|
|
|
+ 4400 5.0 4250 4.7 3970 4.4 3550 4.0
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits. Operation in this zone outside of core airflow limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+ Max. Max. 1000 2000 3000 4000
|
|
|
+ 90%
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Overcurrent FLA Min. Cir. Overcurrent Effectiveness (%)
|
|
|
+ per motor Amps Protection per motor Amps Protection
|
|
|
+
|
|
|
+ Device Device
|
|
|
+
|
|
|
+2.0 120 60 Single 20.0 45.0 60 70%
|
|
|
+
|
|
|
+ 208-230 60 Single 10.8-10.0 24.3 35 6.6-5.8 28.3 30 50%
|
|
|
+
|
|
|
+2.0 208-230 60 Three 6.6-5.8 14.9 20 6.6-5.8 16.3 20 30%
|
|
|
+ 460 60 Three 2.9 6.5 15 At AHRI 1060 standard conditions.
|
|
|
+ 15 2.9 7.2 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ 575 60 Three 2.4 5.4 15 2.4 5.9 15
|
|
|
+
|
|
|
+ 208-230 60 Single 14.7-14 33.1 40 9.4-8.5 40.2 45
|
|
|
+
|
|
|
+3.0 208-230 60 Three 9.4-8.5 21.1 25 9.4-8.5 23.2 25
|
|
|
+ 460 60 Three 4.2 9.5 15
|
|
|
+ 15 4.2 10.5
|
|
|
+
|
|
|
+ 575 60 Three 3.3 7.4 15 3.3 8.2 15
|
|
|
+
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 45 14.5-13.4 35.9 45
|
|
|
+
|
|
|
+5.0 460 60 Three 6.7 15.1 20 6.7 16.6 20
|
|
|
+
|
|
|
+ 575 60 Three 5.3 11.9 15 5.3 13.1 15
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+98 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ 50 5/8" OverallHE4XINV Energy Recovery Ventilator Standard 45 5/8" Minimum ABBREVIATIONS
|
|
|
+ 35 1/8" Case Service Area EA: Exhaust Air to outside
|
|
|
+ 34 1/8" Minimum OA: Outside Air intake
|
|
|
+ Service Area RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ Door INSTALLATION ORIENTATION
|
|
|
+ Swing Unit must be installed in orientation
|
|
|
+ shown.
|
|
|
+ NOTE
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3. MIN. DUCT CLEARANCE
|
|
|
+ FROM DAMPER BLADES WHEN FULLY
|
|
|
+ OPENED TO BE 2". SMACNA RULES
|
|
|
+ APPLY.
|
|
|
+
|
|
|
+ TOP VIEW
|
|
|
+
|
|
|
+ RA Damper RA Inlet OA Damper OA Inlet
|
|
|
+ Location 42" X 14" Location 42" X 14"
|
|
|
+ (Optional) Duct Receiving (Optional) Duct Receiving
|
|
|
+ Flange Flange
|
|
|
+ 1 5/8" Typ. 81 7/8" Overall
|
|
|
+ RA 5" Damper 81 1/2" Case
|
|
|
+ E-Box Frames Typ.
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 99 46 5/8" Typ. Disconnect25 5/8" Wiring 58" Case 62" Overall
|
|
|
+ 10 1/4" Typ. OA
|
|
|
+ Switch
|
|
|
+ FA Pressure Ports
|
|
|
+ (4) Typ.
|
|
|
+
|
|
|
+ EA
|
|
|
+
|
|
|
+ 37 7/8" Typ. CL 5 3/4" Power In 4 1/4" Duct Duct Flange4"
|
|
|
+ CL 2 5/8" Control In Flange Typ. 34" X 12" Typ.
|
|
|
+ (2) 7/8" Holes for
|
|
|
+ CL 8" Wiring RIGHT VIEW
|
|
|
+ Wiring in Bottom
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+ of E-Box Must be mounted as shown. RA/EA airstream can
|
|
|
+ be switched with OA/FA airstream unless certain
|
|
|
+ LEFT VIEW FRONT VIEW options are selected.
|
|
|
+ MAoIRdFeLl:OHWE4CXOINNVFIGURATION
|
|
|
+ DAravaiwlabilne gas sThyopwnein: dUimneintsiDonimdraewinngs.ion
|
|
|
+ Version: MAY18
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 4XINV Energy Recovery Ventilator
|
|
|
+ Standard with Bypass Economizer
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Onboard variable frequency drives (VFDs) -
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE Typical Airflow Range: 1,000-4,400 CFM one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ AHRI 1060 Certified Core: Four L125-G5 Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ Standard Features:
|
|
|
+ TEFC Premium efficiency motors enhanced, premium
|
|
|
+ Motor starters Bypass economizer damper
|
|
|
+ Non-fused disconnect
|
|
|
+ 24 VAC transformer/relay package (see bypass DIM drawing) -
|
|
|
+ Cross-core differential pressure ports dry-bulb temperature controls (standard),
|
|
|
+ enthalpy controls (option)
|
|
|
+ Filters: Class 1 low leakage motorized isolation dampers -
|
|
|
+ Total qty. 8, MERV 8: 20" x 20" x 2" OA, RA or both airstreams
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+ Unit Dimensions & Weight: both airstreams
|
|
|
+ 50 3/4" L x 81 1/2" W x 62" H Double wall construction
|
|
|
+ 753-1,196 lbs., varies by option(s) Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Accessories:
|
|
|
+ 60" L x 90" W x 70" H Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 1,332 lbs. Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ Motor(s): in exterior enclosure (TC7D-E)
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ with adjustable sheaves (see table below) wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+Motor Blower Sheave External Static Pressure (in. w.g.)
|
|
|
+ HP RPM Adj.
|
|
|
+ 2.0 Turns 0.00 0.25 0.50 0.75 1.00 1.25 1.50
|
|
|
+ 1191 Open SCFM BHP
|
|
|
+ 3.0 1329 3330 1.4 SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP
|
|
|
+ 1432 4 3715 1.9
|
|
|
+ 5.0 1466 2 4000 2.4 3015 Th1e.2rmal P2e6r9fo0rmanc1e.0Rating1s91G55 20150.28.xlsx 1085 0.6 4 Cores (IOM)
|
|
|
+ 1462 0.5
|
|
|
+ 1503 0 4060 2.6 3440 1.7 3100 1.5 2485 1.3 2000 1.0 1200 0.8
|
|
|
+ 1586 3 4175 2.8
|
|
|
+ 1668 2.5 3740 2.2 3480 2.0 3050 1.7 2490 1.5 1900 1.2 1100 0.9
|
|
|
+ 1710 1.5 4393 3.9
|
|
|
+ 1627 0.5 3200 1.9 2650 1.6 2120 1.3 1385 1.1
|
|
|
+ 1731 0
|
|
|
+ 1836 4 3810 2.4 3550 2.1 3180 1.9 2645 1.6 2075 1.3 1345 1.0
|
|
|
+ 2
|
|
|
+ 0 3940 2.6 3700 2.4 3340 2.1 2885 1.7 2300 1.5 1600 1.2
|
|
|
+
|
|
|
+ 3950 2.8 3640 2.5 3250 2.3 2745 2.0 2170 1.7
|
|
|
+
|
|
|
+ 3900 3.0 3600 2.7 3155 2.4 2640 2.1
|
|
|
+
|
|
|
+ 3750 3.0 3350 2.7 2975 2.4
|
|
|
+
|
|
|
+ 4210 3.7 4050 3.6 3800 3.3 3490 3.1 3020 2.7 2385 2.4
|
|
|
+
|
|
|
+ 4350 4.3 4150 4.1 3895 3.8 3515 3.5 3055 3.2
|
|
|
+
|
|
|
+ 4400 5.0 4250 4.7 3970 4.4 3550 4.0
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits. Operation in this zone outside of core airflow limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+ Max. Max. 1000 2000 3000 4000
|
|
|
+ 90%
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Overcurrent FLA Min. Cir. Overcurrent Effectiveness (%)
|
|
|
+ per motor Amps Protection per motor Amps Protection
|
|
|
+
|
|
|
+ Device Device
|
|
|
+
|
|
|
+2.0 120 60 Single 20.0 45.0 60 70%
|
|
|
+
|
|
|
+ 208-230 60 Single 10.8-10.0 24.3 35 6.6-5.8 28.3 30 50%
|
|
|
+
|
|
|
+2.0 208-230 60 Three 6.6-5.8 14.9 20 6.6-5.8 16.3 20 30%
|
|
|
+ 460 60 Three 2.9 6.5 15 At AHRI 1060 standard conditions.
|
|
|
+ 15 2.9 7.2 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ 575 60 Three 2.4 5.4 15 2.4 5.9 15
|
|
|
+
|
|
|
+ 208-230 60 Single 14.7-14 33.1 40 9.4-8.5 40.2 45
|
|
|
+
|
|
|
+3.0 208-230 60 Three 9.4-8.5 21.1 25 9.4-8.5 23.2 25
|
|
|
+ 460 60 Three 4.2 9.5 15
|
|
|
+ 15 4.2 10.5
|
|
|
+
|
|
|
+ 575 60 Three 3.3 7.4 15 3.3 8.2 15
|
|
|
+
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 45 14.5-13.4 35.9 45
|
|
|
+
|
|
|
+5.0 460 60 Three 6.7 15.1 20 6.7 16.6 20
|
|
|
+
|
|
|
+ 575 60 Three 5.3 11.9 15 5.3 13.1 15
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+100 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE4XINV Energy Recovery Ventilator Standard with Bypass Economizer
|
|
|
+
|
|
|
+ 5" Typ. 34 1/8" Minimum 42" X 14" Bypass Duct Connection ABBREVIATIONS
|
|
|
+ Service Area (Direct Mount to Damper, By Others) EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ Door BP RA: Room Air to be exhausted
|
|
|
+ Swing FA: Fresh Air to inside
|
|
|
+ 51 3/8" Overall 42 1/2" Minimum RA OA BP: Bypass Air Intake
|
|
|
+ 35 1/8" Service Area Face Bypass INSTALLATION ORIENTATION
|
|
|
+ Case Damper Damper Unit must be installed in orientation
|
|
|
+ shown.
|
|
|
+ FA EA NOTE
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ 5" Typ. BYPASS AIRFLOW SCHEMATIC DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ FRONT VIEW 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ TOP VIEW 3. MIN. DUCT CLEARANCE
|
|
|
+ FROM DAMPER BLADE WHEN FULLY
|
|
|
+ Isolation Damper OPENED TO BE 2". SMACNA RULES
|
|
|
+ (Optional) APPLY.
|
|
|
+ Acts as Face Damper 4. UNITS WITH BYPASS WILL REQUIRE
|
|
|
+ For Bypass Units ADDITIONAL SPACE FOR THE
|
|
|
+ CONNECTION OF THE BYPASS DUCT
|
|
|
+ 1 5/8" (BY OTHERS).
|
|
|
+ 5. FOR INSTALLATION DETAILS, REFER
|
|
|
+ Bypass TO I&O MANUAL SUPPLEMENT FOR
|
|
|
+ Location BYPASS.
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 101 RA Inlet 5" Damper Pressure Ports OA Damper 81 7/8" Overall OA Inlet
|
|
|
+ 42" X 14" Frames Typ. (4) Typ. Location 81 1/2" Case 42" X 14"
|
|
|
+ Duct Receiving (Optional) Duct Receiving
|
|
|
+ Flange RA OA Flange
|
|
|
+
|
|
|
+ 25 5/8" Wiring E-Box 1 5/8"
|
|
|
+
|
|
|
+ 46 5/8" Disconnect BP 42" X 14"4"
|
|
|
+ 10 1/8" Typ. Switch EA Bypass 28"
|
|
|
+ FA 46 5/8"
|
|
|
+ Damper 58" Case
|
|
|
+ Location 62" Overall
|
|
|
+ (Optional)
|
|
|
+
|
|
|
+ 37 3/4" Typ. CL 8" CL 5 5/8" Power In 34" X 12" 5 1/4"
|
|
|
+ Wiring CL 2 1/2" Control In Duct Receiving
|
|
|
+ (2) 7/8" Holes for
|
|
|
+ Wiring in Bottom Flange Typ.
|
|
|
+ of E-Box
|
|
|
+ LEFT VIEW RIGHT VIEW
|
|
|
+ MAoIRdFeLlO: HWE4CXOINNFVIG[BUyRpAaTIsOs]N FRONT VIEW
|
|
|
+ DArvaaiwlabilenags sThyowpnein:dUimnenitsioDn idmraweinng.sion UNIT MOUNTING & APPLICATION
|
|
|
+ Version: MAY18 Must be mounted as shown. Airstreams can not
|
|
|
+ be switched.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 4XRT Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+ROOFTOP UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Onboard variable frequency drives (VFDs) -
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE Typical Airflow Range: 1,000-4,400 CFM one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ AHRI 1060 Certified Core: Four L125-G5 Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ Standard Features:
|
|
|
+ TEFC Premium efficiency motors enhanced, premium
|
|
|
+ Motor starters Class 1 low leakage motorized isolation dampers -
|
|
|
+ Non-fused disconnect
|
|
|
+ 24 VAC transformer/relay package OA, RA or both airstreams
|
|
|
+ Cross-core differential pressure ports Qty. 2, Factory mounted filter alarms -
|
|
|
+
|
|
|
+ Filters: both airstreams
|
|
|
+ Total qty. 8, MERV 8: 20" x 20" x 2" Double wall construction
|
|
|
+ Exterior paint - white, custom colors
|
|
|
+ Unit Dimensions & Weight:
|
|
|
+ 94" L x 83" W x 44" H Accessories:
|
|
|
+ 845-1,143 lbs., varies by option(s) Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Roof curb - standard 14"
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Curb wind clip
|
|
|
+ 80" L x 90" W x 67" H Engineered combo curb for Carrier RTU
|
|
|
+ 1,279 lbs. Engineered combo curb for Trane RTU
|
|
|
+ Digital time clock - wall mount (TC7D-W),
|
|
|
+ Motor(s):
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ with adjustable sheaves (see table below)
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW));
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+Motor Blower Sheave External Static Pressure (in. w.g.)
|
|
|
+ HP RPM Adj.
|
|
|
+ Turns 0.00 0.25 0.50 0.75 1.00 1.25 1.50
|
|
|
+ 1186 Open SCFM BHP
|
|
|
+ 3099 1.5 SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP SCFM BHP
|
|
|
+ 4 2790 Th1e.3rmal P2e2r9fo5rmanc1e.1Rating1s79G05 20150..28.xlsx 1150 4 Cores (IOM)
|
|
|
+ 0.6
|
|
|
+
|
|
|
+2.0 1326 2 3465 2.2 3185 1.9 2810 1.7 2335 1.4 1885 1.2 1290 0.9
|
|
|
+
|
|
|
+ 1466 0 2451 1.8 2026 1.5 1485 1.2
|
|
|
+
|
|
|
+ 1455 4 3812 2.7 3550 2.5 3285 2.3 2820 2.0 2400 1.7 1970 1.5 1450 1.2
|
|
|
+
|
|
|
+ 1527 3 3750 2.9 3500 2.7 3085 2.4 2676 2.1 2300 1.9 1815 1.5
|
|
|
+
|
|
|
+3.0 1598 2 3350 2.6 2950 2.6 2590 2.3 2175 2.0
|
|
|
+
|
|
|
+ 1670 1 3210 3.0 2870 2.7 2500 2.4
|
|
|
+
|
|
|
+ 1742 0 2800 2.9
|
|
|
+
|
|
|
+ 1623 4 4165 3.7 3965 3.5 3750 3.3 3475 3.0 3055 2.5 2685 2.3 2290 2.0
|
|
|
+
|
|
|
+5.0 1728 2 4240 4.3 4050 4.0 3820 3.7 3450 3.3 3050 3.0 2720 2.6
|
|
|
+
|
|
|
+ 1832 0 4345 4.9 4140 4.5 3850 4.2 3490 3.7 3145 3.3
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits. Operation in this zone outside of core airflow limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+ Max. Max. 1000 2000 3000 4000
|
|
|
+ 90%
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Overcurrent FLA Min. Cir. Overcurrent Effectiveness (%)
|
|
|
+ per motor Amps Protection per motor Amps Protection
|
|
|
+
|
|
|
+ Device Device
|
|
|
+
|
|
|
+2.0 120 60 Single 20.0 45.0 60 70%
|
|
|
+
|
|
|
+ 208-230 60 Single 10.8-10.0 24.3 35 6.6-5.8 28.3 30 50%
|
|
|
+
|
|
|
+2.0 208-230 60 Three 6.6-5.8 14.9 20 6.6-5.8 16.3 20 30%
|
|
|
+ 460 60 Three 2.9 6.5 15 At AHRI 1060 standard conditions.
|
|
|
+ 15 2.9 7.2 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ 575 60 Three 2.4 5.4 15 2.4 5.9 15
|
|
|
+
|
|
|
+ 208-230 60 Single 14.7-14 33.1 40 9.4-8.5 40.2 45
|
|
|
+
|
|
|
+3.0 208-230 60 Three 9.4-8.5 21.1 25 9.4-8.5 23.2 25
|
|
|
+ 460 60 Three 4.2 9.5 15
|
|
|
+ 15 4.24 10.5
|
|
|
+
|
|
|
+ 575 60 Three 3.3 7.4 15 3.3 8.2 15
|
|
|
+
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 45 14.5-13.4 35.9 45
|
|
|
+
|
|
|
+5.0 460 60 Three 6.7 15.1 20 6.7 16.6 20
|
|
|
+
|
|
|
+ 575 60 Three 5.3 11.9 15 5.3 13.1 15
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+102 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE4XRT (RTV/RTR) Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ Ty1p.1/8" RA RA ABBREVIATIONS
|
|
|
+ 10" X 52" Damper Location EA: Exhaust Air to outside
|
|
|
+ Opening (Optional) CURB 4X OA: Outside Air intake
|
|
|
+ 31" (Recessed 3/4") RA: Room Air to be exhausted
|
|
|
+ 76 1/2" O.D. FA: Fresh Air to inside
|
|
|
+ 33 5/8" 54 1/4" RTV: Rooftop Vertical RA & FA
|
|
|
+ Minimum RA RTR: Rooftop Vertical RA Only
|
|
|
+ Service Area
|
|
|
+ 2 1T/y8p" . 13 1/4"A INSTALLATION ORIENTATION
|
|
|
+ Unit must be installed in orientation
|
|
|
+ shown.
|
|
|
+
|
|
|
+ NOTE:
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ Door DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ 57 3/8" Case Swing 67 5/8" Minimum 50 3/8" I.D. 54 1/8" O.D. NEAREST EIGHTH OF AN INCH.
|
|
|
+ 47 7/8" Service Area A
|
|
|
+ 17"
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ 13 5/8" TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ Door FA CURB CROSS-SECTION A-A (TYP.)
|
|
|
+ Swing 34"
|
|
|
+ 72 3/4" I.D.
|
|
|
+ 14 3/4" 4 5/8" 1 1/2" X 1/4" 1 7/8"
|
|
|
+ TOP VIEW Neoprene Gasket
|
|
|
+
|
|
|
+ FA (RTV) 16 1/8" 10 1/8" 3/4" X 3 1/2"
|
|
|
+ (2) 6 7/8" X 11" 36 5/8"
|
|
|
+ Openings Wooden Nailer 14"
|
|
|
+ 3"
|
|
|
+
|
|
|
+ TOP VIEW SECTION A-A
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 103 EA Outlet 93 7/8" Overall 82 7/8" Overall OA
|
|
|
+ 81 3/8" Case Damper
|
|
|
+ 54 1/2" Location
|
|
|
+ Lifting Lugs 79 1/8" Lifting Lugs (Optional)
|
|
|
+
|
|
|
+ 12 3/4" Wiring E-Box 2" Pressure Ports
|
|
|
+ (4) Typ.
|
|
|
+ 44" Overall EA
|
|
|
+ 37 3/8" Case OA
|
|
|
+
|
|
|
+ 6 1/8" FA RTR
|
|
|
+ ONLY
|
|
|
+
|
|
|
+ 38 7/8" CL 5 1/4" Disconnect FA
|
|
|
+ FA (RTR) Wiring Switch RTV
|
|
|
+ 3 5/8" ONLY RA
|
|
|
+ 32" X 12" CL 5 3/4" Power In
|
|
|
+ Duct Receiving
|
|
|
+ CL 2 5/8" Control In
|
|
|
+ Flange (2) 7/8" Holes
|
|
|
+ for wiring in bottom
|
|
|
+ of E-Box
|
|
|
+ HERT except 6x 8x, LERT HERT except 6x 8x, LERT
|
|
|
+ LEFT VIEW
|
|
|
+ FRONT VIEW RIGHT VIEW
|
|
|
+
|
|
|
+ MoAIdReFlL: OHWE4CXORNTVFI/GRUTRRATION RTV RTR UNIT MOUNTING & APPLICATION
|
|
|
+ Must be mounted as shown. Airstreams can not
|
|
|
+ DrAavawilaibnlegasTsyhopwen:: Unit Dimension EA OA EA OA be switched.
|
|
|
+
|
|
|
+ Version: MAY18 FA
|
|
|
+
|
|
|
+ FA RA RA
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+ 2 1T/y8p" .
|
|
|
+104 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE4XRT (RTH/RTF) Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+Typ1. 1/8" ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ CURB 4X OA: Outside Air intake
|
|
|
+ RA: Room Air to be exhausted
|
|
|
+ 76 1/2" O.D. FA: Fresh Air to inside
|
|
|
+ 54 1/4" RTF: Rooftop Vertical FA Only
|
|
|
+ RA RTH: Rooftop Horizontal RA & FA
|
|
|
+ A
|
|
|
+ 33 5/8" 13 1/4" INSTALLATION ORIENTATION
|
|
|
+ Minimum FA Unit must be installed in orientation
|
|
|
+ Service Area 34" shown.
|
|
|
+ 72 3/4" I.D.
|
|
|
+ Door NOTE:
|
|
|
+ Swing TOP VIEW 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+57 3/8" Case 67 5/8" Minimum 50 3/8" I.D. 54 1/8" O.D. NEAREST EIGHTH OF AN INCH.
|
|
|
+ 17" Service Area A
|
|
|
+
|
|
|
+ 13 5/8" FA 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ Door CURB CROSS-SECTION A-A (TYP.)
|
|
|
+ Swing
|
|
|
+
|
|
|
+ 14 3/4" 4 5/8" 1 1/2" X 1/4" 1 7/8"
|
|
|
+ Neoprene Gasket
|
|
|
+
|
|
|
+FA (RTF) 16 1/8" 10 1/8" 3/4" X 3 1/2"
|
|
|
+(2) 6 7/8" X 11" 36 5/8"
|
|
|
+Openings Wooden Nailer 14"
|
|
|
+ 3" 6"
|
|
|
+
|
|
|
+ TOP VIEW SECTION A-A
|
|
|
+
|
|
|
+ EA Outlet 93 7/8" Overall 82 7/8" Overall OA
|
|
|
+ 81 3/8" Case Damper
|
|
|
+ 54 1/2" Location
|
|
|
+ Lifting Lugs 79 1/8" Lifting Lugs (Optional)
|
|
|
+
|
|
|
+ 12 3/4" Wiring E-Box 2" Pressure Ports
|
|
|
+ (4) Typ.
|
|
|
+44" Overall EA
|
|
|
+ 37 3/8" Case OA
|
|
|
+
|
|
|
+ 6 1/8" FA RTH RA
|
|
|
+ ONLY
|
|
|
+ 5" Damper
|
|
|
+3 5/8" 38 7/8" CL 5 1/4" Disconnect FA Frames Typ. RA 19 1/4"
|
|
|
+ FA (RTH) Wiring Switch 42" X 14"
|
|
|
+ RTF Duct Receiving RA
|
|
|
+ 32" X 12" CL 5 3/4" Power In ONLY Flange Damper Location
|
|
|
+ Duct Receiving (Optional)
|
|
|
+ CL 2 5/8" Control In FRONT VIEW
|
|
|
+ Flange (2) 7/8" Holes
|
|
|
+ for wiring in bottom
|
|
|
+ of E-Box
|
|
|
+ HERT except 6x 8x, LERT HERTexcept 6x 8x, LERT
|
|
|
+ LEFT VIEW
|
|
|
+ RIGHT VIEW
|
|
|
+
|
|
|
+MoAIdReFlL:OHWE4CXORNTHFI/GRUTRF ATION RTH RTF UNIT MOUNTING & APPLICATION
|
|
|
+DrAavawilaibnlegasTsyhopwen:: Unit Dimension EA
|
|
|
+Version: MAY 18 OA EA OA Must be mounted as shown. Airstreams can not
|
|
|
+ FA RA be switched.
|
|
|
+ RA
|
|
|
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 105
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 4XRTC Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+ROOFTOP UNIT SPECIFICATIONS
|
|
|
+Direct Connect
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Onboard variable frequency drives (VFDs) -
|
|
|
+
|
|
|
+ Typical Airflow Range: 2,500-3,900 CFM one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ AHRI 1060 Certified Core: Four L125-G5 Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ Standard Features:
|
|
|
+ TEFC Premium efficiency motors enhanced, premium
|
|
|
+ Motor starters Qty. 2, Factory mounted filter alarms -
|
|
|
+ Non-fused disconnect
|
|
|
+ 24 VAC transformer/relay package both airstreams
|
|
|
+ Cross-core differential pressure ports Double wall construction
|
|
|
+ Exterior paint - white, custom colors
|
|
|
+ Filters:
|
|
|
+ Total qty. 8, MERV 8: (4) 20" x 20" x 2" and Accessories:
|
|
|
+ Filters - MERV 13, 2" (shipped loose)
|
|
|
+ (4) 16" x 20" x 2" RTC transition kit - for vertical RTU, for horizontal RTU
|
|
|
+ Rooftop RTC transition paint - white, custom colors
|
|
|
+ Unit Dimensions & Weight: Digital time clock - wall mount (TC7D-W),
|
|
|
+ 81 1/4" L x 83 1/4" W x 48 1/4" H
|
|
|
+ 887-1,169 lbs., varies by option(s) in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet):
|
|
|
+ 80" L x 90" W x 80" H wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ 1,300 lbs. IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ Motor(s): duct mount (IAQ-D)
|
|
|
+ Qty. 2, 5.0 HP ea., Belt drive blower/standard motor Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ packages with adjustable sheaves ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE Note: Electric Duct Heater and Indirect Gas-Fired Duct Furnace are not available on RTC units.
|
|
|
+
|
|
|
+ Tie-In Directly to Rooftop A/C Unit* Unit Ducted Independently*
|
|
|
+
|
|
|
+ Blower RPM Sheave Adj. Static Pressure in Adjacent Air Handler External Static Pressure (Inches Water Column)
|
|
|
+ Nominal Turns Open
|
|
|
+ (Inches Water Column)
|
|
|
+
|
|
|
+ -0.75 -0.5 -0.25 0.0 +0.25 +0.5 +0.75
|
|
|
+ CFM BHP CFM BHP CFM BHP CFM BHP
|
|
|
+ CFM BHP CFM BHP CFM BHP
|
|
|
+
|
|
|
+ 1510 0 3400 3.1 3700 3.3 4000 3.6 4250 4.1 4000 3.6 3700 3.3 3400 3.1
|
|
|
+
|
|
|
+ 1465 1 3275 3.0 3600 3.2 3925 3.4 4225 3.8 3925 3.4 3600 3.2 3275 3.0
|
|
|
+
|
|
|
+ 1420 2 3125 2.8 3450 2.9 3775 3.0 4156 3.6 3775 3.0 3450 2.9 3125 2.8
|
|
|
+
|
|
|
+Exhaust Air 1375 3 2935 2.3 3300 2.5 3665 2.8 4067 3.4 3665 2.8 3300 2.5 2935 2.3
|
|
|
+
|
|
|
+ 1330 4 2780 2.0 3150 2.3 3520 2.5 3900 3.1 3520 2.5 3150 2.3 2780 2.0
|
|
|
+
|
|
|
+ 1285 5 2685 1.6 T3h0e5r0mal Pe2.r0forma3n4c1e5 Ratin2g.4s G5 23071605.2.xls2x.8 3415 2.4 30450Cores2.(0IOM) 2685 1.6
|
|
|
+
|
|
|
+ 1240 6 2620 1.4 2950 1.7 3280 2.0 3600 2.4 3280 2.0 2950 1.7 2620 1.4
|
|
|
+
|
|
|
+ 1825 0 3245 5.0
|
|
|
+
|
|
|
+ 1770 1 3225 4.9 3125 4.6
|
|
|
+
|
|
|
+ 1715 2 3450 4.8 3275 4.6 3140 4.5 3005 4.3
|
|
|
+
|
|
|
+Fresh Air 1660 3 3920 5.0 3760 5.0 3600 5.0 3360 4.5 3180 4.1 3060 4.0 2940 3.9
|
|
|
+
|
|
|
+ 1605 4 3790 4.6 3670 4.6 3550 4.7 3270 4.1 3090 3.7 2970 3.7 2850 3.7
|
|
|
+
|
|
|
+ 1550 5 3724 4.2 3582 4.3 3440 4.5 3190 3.6 3010 3.4 2890 3.3 2770 3.3
|
|
|
+
|
|
|
+ 1495 6 3680 4.2 3500 4.1 3320 3.9 3100 3.5 2910 2.9 2790 2.8 2670 2.8
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+* See page 38 for installation details.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+ Max. Max. 1000 2000 3000 4000
|
|
|
+ 90%
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Overcurrent FLA Min. Cir. Overcurrent Effectiveness (%)
|
|
|
+ per motor Amps Protection per motor Amps Protection
|
|
|
+
|
|
|
+ Device Device 70%
|
|
|
+
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 45 14.5-13.4 35.9 45
|
|
|
+
|
|
|
+5.0 460 60 Three 6.7 15.1 20 6.7 16.6 20 50%
|
|
|
+
|
|
|
+ 575 60 Three 5.3 11.9 15 5.3 13.1 15
|
|
|
+
|
|
|
+Specifications may be subject to change without notice. 30%
|
|
|
+ At AHRI 1060 standard conditions.
|
|
|
+
|
|
|
+ See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+106 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE4XRTC Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ 1/8" ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ 1 OA: Outside Air intake
|
|
|
+ Typ. RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ 2 1T/y8p" . 33 7/8" Minimum INSTALLATION ORIENTATION
|
|
|
+ Service Area Unit must be installed in orientation
|
|
|
+ shown.
|
|
|
+ 57 3/8" Case Door NOTE:
|
|
|
+ Swing 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ 10 1/8" DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ 67 5/8" Minimum NEAREST EIGHTH OF AN INCH.
|
|
|
+ Service Area 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ Door
|
|
|
+ Swing
|
|
|
+
|
|
|
+ 17 1/2"
|
|
|
+ 23 5/8"
|
|
|
+
|
|
|
+ TOP VIEW
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 107 79 1/8" 81 1/4" Overall 11 1/4" Typ. 83 1/4" Overall
|
|
|
+ 54 1/2" 81 1/4" Case
|
|
|
+ Lifting Lugs Pressure Ports
|
|
|
+ Lifting Lugs (4) Typ.
|
|
|
+ OA Inlet EA Outlet
|
|
|
+ FA
|
|
|
+ 48 1/4" Overall 5 1/2" Wiring E-Box RA
|
|
|
+ 45 1/4" Case
|
|
|
+ EA
|
|
|
+
|
|
|
+ OA 25 5/8"
|
|
|
+
|
|
|
+ CL 8 3/4" Disconnect 37" Typ. 39 7/8" Typ.
|
|
|
+ Wiring Switch
|
|
|
+ 6 5/8"
|
|
|
+ LEFT VIEW CL 5 3/4" Power In
|
|
|
+ AIRFLOW CONFIGURATION CL 2 5/8" Control In
|
|
|
+ (2) 7/8" Holes
|
|
|
+ MAovdailaeblle: aHs Esh4owXnRinTCdimension drawing. for Wiring in
|
|
|
+ Drawing Type: Unit Dimension Bottom of E-Box
|
|
|
+ Version: MAY18
|
|
|
+ FRONT VIEW RIGHT VIEW
|
|
|
+
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+ Must be mounted as shown. Airstreams can not
|
|
|
+ be switched.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS Energy Recovery Ventilator For safety listed products,
|
|
|
+ Standarrdd & Bypass Economizer Option see LE-SERIES models.
|
|
|
+HE 6XIN
|
|
|
+ SPECIFICATIONS
|
|
|
+INDOOR UNIT
|
|
|
+ Ventilation Type: Options:
|
|
|
+Download specification at: Static plate, heat and humidity transfer Onboard variable frequency drives (VFDs) -
|
|
|
+renewaire.com/specifications
|
|
|
+ Typical Airflow Range: 1,500-6,500 CFM one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ AHRI 1060 Certified Core: Fused disconnect
|
|
|
+ Six L125-G5 Integrated programmable controls -
|
|
|
+
|
|
|
+ Standard Features: enhanced, premium
|
|
|
+ TEFC Premium efficiency motors Bypass economizer damper
|
|
|
+ Motor starters
|
|
|
+ Non-fused disconnect (see bypass DIM drawing) -
|
|
|
+ 24 VAC transformer/relay package dry-bulb temperature controls (standard),
|
|
|
+ Cross-core differential pressure ports enthalpy controls (option)
|
|
|
+ Class 1 low leakage motorized isolation dampers -
|
|
|
+ Filters: OA, EA or both airstreams
|
|
|
+ Total qty. 12, MERV 8: 20" x 20" x 2" Qty. 2, Factory mounted filter alarms -
|
|
|
+ both airstreams
|
|
|
+ Unit Dimensions & Weight: Double wall construction
|
|
|
+ 88" L x 113 1/2" W x 81 3/4" H Exterior paint - white, custom colors
|
|
|
+ 2,235-3,099 lbs., varies by option(s)
|
|
|
+ Accessories:
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 116" L x 90" W x 90" H Digital time clock - wall mount (TC7D-W),
|
|
|
+ 3,439 lbs.
|
|
|
+ in exterior enclosure (TC7D-E)
|
|
|
+ Motor(s): Carbon dioxide sensor/control -
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ with adjustable sheaves (see table below) IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+Motor Blower Sheave 0.00 External Static Pressure (in. w.g.) 1.50 6 Cores1.(7I5OM) 2.00
|
|
|
+ HP RPM Adj. CFM BHP CFM BHP CFM BHP CFM BHP
|
|
|
+ Turns 5005 3.2 0.25 Therm0a.5l0Performanc0e.7R5atings G5 21.00105.2.xlsx 1.25 3750 2.8 3400 2.7 3100 2.5
|
|
|
+ 5.0 1460 Open 5550 4.2 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 4500 3.8 4250 3.7 4000 3.6
|
|
|
+ 1610 4800 3.2 4650 3.1 4475 3.0 4200 2.9 4000 2.8 5050 4.8 4800 4.6 4600 4.5
|
|
|
+ 7.5 1725 4.5 5275 3.7 5375 4.2 5250 4.1 5100 4.1 4900 4.0 4650 3.9 4125 3.3 3875 3.2 3575 3.1
|
|
|
+ 1560 5950 5.0 4950 4.7 4750 4.6 4525 4.5
|
|
|
+ 1740 2 6500 6.5 5525 5.0 5475 5.0 5200 4.9 5625 6.1 5410 6.1 5300 6.0
|
|
|
+ 1865 5200 3.6 4900 3.5 4775 3.5 4550 3.4 4350 3.3
|
|
|
+ 0 5825 5.0 5625 4.9 5490 4.9 5325 4.8 5125 4.7
|
|
|
+ 6350 6.5 6225 6.4 6125 6.4 5910 6.3 5825 6.2
|
|
|
+ 4.5
|
|
|
+
|
|
|
+ 2
|
|
|
+
|
|
|
+ 0
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+ 1000 2000 3000 4000 5000 6000 7000
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Max. FLA per Min. Cir. Max. 90%Effectiveness (%)
|
|
|
+ per motor Amps Overcurrent motor Amps Overcurrent
|
|
|
+ Protection Protection 70%
|
|
|
+ 14.5-13.4 32.6
|
|
|
+ 6.7 15.1 Device Device 50%
|
|
|
+ 5.3 11.9
|
|
|
+ 208-230 60 Three 45 14.5-13.4 35.9 45 30%
|
|
|
+5.0 460 60 Three 21.0-19.0 47.3 20 At AHRI 1060 standard conditions.
|
|
|
+ Three 9.5 21.4 15 6.7 16.6 20 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+ 575 60 7.6 17.1
|
|
|
+ Three 60 5.3 13.1 15
|
|
|
+ 208-230 60 Three 25
|
|
|
+7.5 460 60 Three 20 21.0-19.0 52.0 60
|
|
|
+
|
|
|
+ 575 60 9.5 23.5 25
|
|
|
+
|
|
|
+ 7.6 18.8 20
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+108 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE6XIN Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ OA34 3/4" ABBREVIATIONS
|
|
|
+ RAMinimum EA: Exhaust Air to outside
|
|
|
+ Service Area OA: Outside Air intake
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 109 RA: Room Air to be exhausted
|
|
|
+ 34 3/4" Minimum Area Door 112 5/8" FA: Fresh Air to inside
|
|
|
+ Service Swing Case INSTALLATION ORIENTATION
|
|
|
+ 113 1/8" Unit must be installed in orientation
|
|
|
+ FA EA Overall shown.
|
|
|
+ NOTE
|
|
|
+ 62" 1.ALL UNITS HAVE INTERNAL EA
|
|
|
+ BACKDRAFT DAMPER.
|
|
|
+ UNLESS AN EA MOTORIZED ISOLATION
|
|
|
+ DAMPER IS SPECIFIED.
|
|
|
+ 2.UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 3.SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 39 1/4" Door Door 69 1/4"
|
|
|
+ Minimum Swing Swing
|
|
|
+ Service
|
|
|
+
|
|
|
+ Area
|
|
|
+
|
|
|
+ 85 5/8" E-Box
|
|
|
+ Minimum Minimum
|
|
|
+ Service Area 36" Service Area
|
|
|
+
|
|
|
+ FA Blower Outlet is 16" X 22" (Nom.) TOP VIEW Power and Control Wiring 24" X 36"
|
|
|
+ 24"X36" Duct Receiving Flange is Entries 7/8" Dia. Duct Receiving
|
|
|
+ also supplied. Field install only in 86 1/2" Overall INDOOR UNITS: EA BLOWER Outlet is Flange Typ.
|
|
|
+ location shown. 75 7/8" Lift Lugs
|
|
|
+ 16" X 22" (Nom.) 24"X36" 85 5/8" Case
|
|
|
+ 102 7/8" Lift Lugs Duct Receiving Flange is also supplied.
|
|
|
+
|
|
|
+ Core Field install only in location shown.
|
|
|
+Access
|
|
|
+ 78 1/4" Case 31 3/4"
|
|
|
+ Door 81 5/8" Overall
|
|
|
+
|
|
|
+Pressure
|
|
|
+Ports
|
|
|
+(4) Typ.
|
|
|
+
|
|
|
+2 1/4" 63 1/4" 10 1/4" 81" 63 1/4" 8 3/4" 22" Typ.
|
|
|
+ 49 5/8"
|
|
|
+ LEFT VIEW FRONT VIEW 108" Internal OA Damper
|
|
|
+MAoIRdFeLl:OHWE6CXIONNFIGURATION Internal EA Motorized Location (Optional)
|
|
|
+DAravawilabinlegasTsyhpowen:inUdnimitenDsiiomn deranwsiniog.n Damper Location (Optional)
|
|
|
+Version: AUG18 BACK VIEW
|
|
|
+ RIGHT VIEW
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+ Must be mounted as shown. Airstreams can not
|
|
|
+ be switched.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS Energy Recovery Ventilator For safety listed products,
|
|
|
+ Standard with Bypass Economizer see LE-SERIES models.
|
|
|
+HE 6XIN
|
|
|
+ SPECIFICATIONS
|
|
|
+INDOOR UNIT
|
|
|
+ Ventilation Type: Options:
|
|
|
+Download specification at: Static plate, heat and humidity transfer Onboard variable frequency drives (VFDs) -
|
|
|
+renewaire.com/specifications
|
|
|
+ Typical Airflow Range: 1,500-6,500 CFM one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ AHRI 1060 Certified Core: Fused disconnect
|
|
|
+ Six L125-G5 Integrated programmable controls -
|
|
|
+
|
|
|
+ Standard Features: enhanced, premium
|
|
|
+ TEFC Premium efficiency motors Bypass economizer damper
|
|
|
+ Motor starters
|
|
|
+ Non-fused disconnect (see bypass DIM drawing) -
|
|
|
+ 24 VAC transformer/relay package dry-bulb temperature controls (standard),
|
|
|
+ Cross-core differential pressure ports enthalpy controls (option)
|
|
|
+ Class 1 low leakage motorized isolation dampers -
|
|
|
+ Filters: OA, EA or both airstreams
|
|
|
+ Total qty. 12, MERV 8: 20" x 20" x 2" Qty. 2, Factory mounted filter alarms -
|
|
|
+ both airstreams
|
|
|
+ Unit Dimensions & Weight: Double wall construction
|
|
|
+ 88" L x 113 1/2" W x 81 3/4" H Exterior paint - white, custom colors
|
|
|
+ 2,235-3,099 lbs., varies by option(s)
|
|
|
+ Accessories:
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 116" L x 90" W x 90" H Digital time clock - wall mount (TC7D-W),
|
|
|
+ 3,439 lbs.
|
|
|
+ in exterior enclosure (TC7D-E)
|
|
|
+ Motor(s): Carbon dioxide sensor/control -
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ with adjustable sheaves (see table below) IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+Motor Blower Sheave 0.00 External Static Pressure (in. w.g.) 1.50 6 Cores1.(7I5OM) 2.00
|
|
|
+ HP RPM Adj. CFM BHP CFM BHP CFM BHP CFM BHP
|
|
|
+ Turns 5005 3.2 0.25 Therm0a.5l0Performanc0e.7R5atings G5 21.00105.2.xlsx 1.25 3750 2.8 3400 2.7 3100 2.5
|
|
|
+ 5.0 1460 Open 5550 4.2 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 4500 3.8 4250 3.7 4000 3.6
|
|
|
+ 1610 4800 3.2 4650 3.1 4475 3.0 4200 2.9 4000 2.8 5050 4.8 4800 4.6 4600 4.5
|
|
|
+ 7.5 1725 4.5 5275 3.7 5375 4.2 5250 4.1 5100 4.1 4900 4.0 4650 3.9 4125 3.3 3875 3.2 3575 3.1
|
|
|
+ 1560 5950 5.0 4950 4.7 4750 4.6 4525 4.5
|
|
|
+ 1740 2 6500 6.5 5525 5.0 5475 5.0 5200 4.9 5625 6.1 5410 6.1 5300 6.0
|
|
|
+ 1865 5200 3.6 4900 3.5 4775 3.5 4550 3.4 4350 3.3
|
|
|
+ 0 5825 5.0 5625 4.9 5490 4.9 5325 4.8 5125 4.7
|
|
|
+ 6350 6.5 6225 6.4 6125 6.4 5910 6.3 5825 6.2
|
|
|
+ 4.5
|
|
|
+
|
|
|
+ 2
|
|
|
+
|
|
|
+ 0
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+ 1000 2000 3000 4000 5000 6000 7000
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Max. FLA per Min. Cir. Max. 90%Effectiveness (%)
|
|
|
+ per motor Amps Overcurrent motor Amps Overcurrent
|
|
|
+ Protection Protection 70%
|
|
|
+ 14.5-13.4 32.6
|
|
|
+ 6.7 15.1 Device Device 50%
|
|
|
+ 5.3 11.9
|
|
|
+ 208-230 60 Three 45 14.5-13.4 35.9 45 30%
|
|
|
+5.0 460 60 Three 21.0-19.0 47.3 20 At AHRI 1060 standard conditions.
|
|
|
+ Three 9.5 21.4 15 6.7 16.6 20 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+ 575 60 7.6 17.1
|
|
|
+ Three 60 5.3 13.1 15
|
|
|
+ 208-230 60 Three 25
|
|
|
+7.5 460 60 Three 20 21.0-19.0 52.0 60
|
|
|
+
|
|
|
+ 575 60 9.5 23.5 25
|
|
|
+
|
|
|
+ 7.6 18.8 20
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+110 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE6XIN Energy Recovery Ventilator Standard with Bypass Economizer
|
|
|
+
|
|
|
+ ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ BP: Bypass Air Intake
|
|
|
+ BP34 3/4"
|
|
|
+ Minimum INSTALLATION ORIENTATION
|
|
|
+ OAService Area Unit must be installed in orientation shown.
|
|
|
+ RA
|
|
|
+ 16" X 38" Bypass Duct Connection 34 3/4" Minimum Area 16" X 38" Bypass NOTE
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 111(Direct Mount to Damper, By Others)Service Damper Location 1.ALL UNITS HAVE INTERNAL EA BACKDRAFT DAMPER.
|
|
|
+ UNLESS AN EA MOTORIZED ISOLATION DAMPER IS
|
|
|
+Bypass BP Door Optional 112 5/8" Case SPECIFIED.
|
|
|
+ Swing 116 3/4" Overall
|
|
|
+ 5 1/8"
|
|
|
+Damper
|
|
|
+
|
|
|
+ 2.UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE
|
|
|
+ ROUNDED TO THE NEAREST EIGHTH OF AN INCH.
|
|
|
+ FA EA
|
|
|
+
|
|
|
+EA RA 62" 3.SPECIFICATIONS MAY BE SUBJECT TO CHANGE
|
|
|
+ WITHOUT NOTICE.
|
|
|
+
|
|
|
+ Face Damper 4. DAMPER SWINGS IN DIRECTION OF AIRFLOW. MIN.
|
|
|
+ DUCT CLEARANCE FROM DAMPER BLADE WHEN
|
|
|
+BYPASS AIRFLOW SCHEMATIC FULLY OPENED TO BE 2". SMACNA RULES APPLY.
|
|
|
+
|
|
|
+ RIGHT VIEW 39 1/4" 32 3/8" Door Door 69 1/4" 5. UNITS WITH BYPASS WILL REQUIRE ADDITIONAL
|
|
|
+ (OA/FA Airstream Not Shown) Minimum Swing Swing SPACE FOR THE CONNECTION OF THE BYPASS DUCT
|
|
|
+ Service (BY OTHERS).
|
|
|
+ FA Blower Outlet is 16" X 22" (Nom.)
|
|
|
+ 24" X 36" Duct Flange is also supplied. Area
|
|
|
+
|
|
|
+ Field install only in location shown. 6. FOR INSTALLATION DETAILS, REFER TO I&O
|
|
|
+ 102 7/8" Lifting Lugs MANUAL SUPPLEMENT FOR BYPASS.
|
|
|
+ 85 5/8" E-Box
|
|
|
+ Minimum Minimum
|
|
|
+ Service Area 36" Service Area
|
|
|
+
|
|
|
+ TOP VIEW 26" X 38" RA Face
|
|
|
+
|
|
|
+ 6 3/8" Typ. 86 5/8" Overall Power and Control Wiring Damper Location
|
|
|
+ 85 5/8" Case Entries 7/8" Dia. Optional
|
|
|
+
|
|
|
+5" Typ. 75 7/8" Lifting Lugs INDOOR UNITS: EA BLOWER Outlet is OA Duct
|
|
|
+ 16" X 22" (Nom.) 24"X36" Duct Flange Flange
|
|
|
+ is also supplied. Field install only in 24" X 36"
|
|
|
+ location shown.
|
|
|
+
|
|
|
+ 2"
|
|
|
+
|
|
|
+ Core 78 1/4" Case 53 1/2"
|
|
|
+ Access 83 3/8" Overall 22"
|
|
|
+
|
|
|
+ Door 21 1/8"
|
|
|
+
|
|
|
+Pressure Ports
|
|
|
+(4) Typ.
|
|
|
+
|
|
|
+ 6 3/8"
|
|
|
+ Typ.
|
|
|
+
|
|
|
+ 63 1/4" 81" 63 1/4" 8 3/4"
|
|
|
+ 48 3/4"
|
|
|
+ 2 1/4" 4" 108" Internal OA Damper
|
|
|
+ 10 1/2" Internal EA Motorized Location (Optional)
|
|
|
+ Damper Location (Optional)
|
|
|
+ LEFT VIEW FRONT VIEW BACK VIEW
|
|
|
+MAoIRdFeLl:OHWE6CXOINN[FBIyGpUaRssA]TION RIGHT VIEW
|
|
|
+DArvaaiwlabilne gas Tshyopwen :inUdinmietnDsioimn deranwsiniog.n UNIT MOUNTING & APPLICATION
|
|
|
+Version: AUG18 Must be mounted as shown. Airstreams can not
|
|
|
+ be switched.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS Energy Recovery Ventilator For safety listed products,
|
|
|
+ Standard see LE-SERIES models.
|
|
|
+HE 6XRT
|
|
|
+ SPECIFICATIONS Options:
|
|
|
+ROOFTOP UNIT Onboard variable frequency drives (VFDs) -
|
|
|
+ Ventilation Type:
|
|
|
+Download specification at: Static plate, heat and humidity transfer one or both airstreams
|
|
|
+renewaire.com/specifications Shaft grounding ring on motors with VFDs
|
|
|
+ Typical Airflow Range: 1,500-6,500 CFM Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ AHRI 1060 Certified Core:
|
|
|
+ Six L125-G5 enhanced, premium
|
|
|
+ Class 1 low leakage motorized isolation dampers -
|
|
|
+ Standard Features:
|
|
|
+ TEFC Premium efficiency motors OA, EA or both airstreams
|
|
|
+ Motor starters Qty. 2, Factory mounted filter alarms -
|
|
|
+ Non-fused disconnect
|
|
|
+ 24 VAC transformer/relay package both airstreams
|
|
|
+ Cross-core differential pressure ports Double wall construction
|
|
|
+ Exterior paint - white, custom colors
|
|
|
+ Filters:
|
|
|
+ Total qty. 12, MERV 8: 20" x 20" x 2" Accessories:
|
|
|
+ Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Unit Dimensions & Weight: Roof curb - standard 14"
|
|
|
+ 106 1/2" L x 113 1/2" W x 81 3/4" H Curb wind clip
|
|
|
+ 2,301-3,166 lbs., varies by option(s) Engineered combo curb for Carrier RTU
|
|
|
+ Engineered combo curb for Trane RTU
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Digital time clock - wall mount (TC7D-W),
|
|
|
+ 116" L x 90" W x 90" H
|
|
|
+ 3,599 lbs. in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ Motor(s):
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+ with adjustable sheaves (see table below)
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+ Sheave External Static Pressure (in. w.g.)
|
|
|
+ Adj.
|
|
|
+Motor HP Blower Turns 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00
|
|
|
+ RPM Open CFM BHP
|
|
|
+ 5005 3.2 Thermal Performance Ratings G5 2015.2.xlsx 6 Cores (IOM)
|
|
|
+ 4.5 5550 4.2 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
|
|
|
+
|
|
|
+ 1460 2 5275 3.7 4800 3.2 4650 3.1 4475 3.0 4200 2.9 4000 2.8 3750 2.8 3400 2.7 3100 2.5
|
|
|
+ 5950 5.0
|
|
|
+5.0 1610 0 6500 6.5 5375 4.2 5250 4.1 5100 4.1 4900 4.0 4650 3.9 4500 3.8 4250 3.7 4000 3.6
|
|
|
+
|
|
|
+ 1725 4.5 5525 5.0 5475 5.0 5200 4.9 5050 4.8 4800 4.6 4600 4.5
|
|
|
+
|
|
|
+ 1560 2 5200 3.6 4900 3.5 4775 3.5 4550 3.4 4350 3.3 4125 3.3 3875 3.2 3575 3.1
|
|
|
+
|
|
|
+7.5 1740 0 5825 5.0 5625 4.9 5490 4.9 5325 4.8 5125 4.7 4950 4.7 4750 4.6 4525 4.5
|
|
|
+
|
|
|
+ 1865 6350 6.5 6225 6.4 6125 6.4 5910 6.3 5825 6.2 5625 6.1 5410 6.1 5300 6.0
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA Optional Factory Installed CORE PERFORMANCE
|
|
|
+ Standard Electrical Specifications VFD Electrical Specifications
|
|
|
+ Airflow (CFM)
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Max. FLA Min. Cir. Max. Effectiveness (%)
|
|
|
+ per motor Amps Overcurrent per motor Amps Overcurrent 1000 2000 3000 4000 5000 6000 7000
|
|
|
+ Protection Protection 90%
|
|
|
+
|
|
|
+ Device Device 70%
|
|
|
+
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 45 14.5-13.4 35.9 45 50%
|
|
|
+ 20
|
|
|
+5.0 460 60 Three 6.7 15.1 15 6.7 16.6 20 30%
|
|
|
+ At AHRI 1060 standard conditions.
|
|
|
+ 575 60 Three 5.3 11.9 60 5.3 13.1 15 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+ 25
|
|
|
+ 208-230 60 Three 21.0-19.0 47.3 20 21.0-19.0 52.0 60
|
|
|
+
|
|
|
+7.5 460 60 Three 9.5 21.4 9.5 23.5 25
|
|
|
+
|
|
|
+ 575 60 Three 7.6 17.1 7.6 18.8 20
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+112 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE6XRT Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ 121 1/4" Minimum 39 1/2" ABBREVIATIONS
|
|
|
+ Service Area EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ 65 3/4" Minimum Door Door FA (RTV, RTF) CURB 6X RA: Room Air to be exhausted
|
|
|
+ Service Area Swing Swing 16" X 22" FA: Fresh Air to inside
|
|
|
+ 76" O.D. RTV: Rooftop Vertical RA & FA
|
|
|
+ 15 3/4" 36" RTF: Rooftop Vertical FA Only
|
|
|
+ 135 3/4" Minimum RTR: Rooftop Vertical RA Only
|
|
|
+ 26 1/4" Service Area 26" RTH: Rooftop Horizontal RA & FA
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ 71 1/2" Door 99 1/4" I.D. FA 31" 103" O.D. Unit must be installed in orientation
|
|
|
+ Swing shown.
|
|
|
+ A NOTE:
|
|
|
+ RA 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ 36" DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 72 1/4" I.D. 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ TOP VIEW
|
|
|
+ A
|
|
|
+
|
|
|
+ CURB CROSS-SECTION A-A (TYP.)
|
|
|
+
|
|
|
+ 1 1/2" X 1/4" 1 7/8"
|
|
|
+ Neoprene Gasket
|
|
|
+ 19 7/8" 54 7/8" 20" Minimum 26"
|
|
|
+ 60 7/8" Service Area 3/4" X 3 1/2"
|
|
|
+ Wooden Nailer
|
|
|
+ TOP VIEW RA (RTV, RTR)
|
|
|
+ 24" X 34" 3"
|
|
|
+
|
|
|
+ 14"
|
|
|
+
|
|
|
+ SECTION A-A
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 113 OA Inlet OA Damper RA Inlet Pressure 113 1/8" Overall 1 1/4" Disconnect
|
|
|
+ Louver Location (RTH, RTF) Ports Typ. Switch
|
|
|
+ (Optional) 24" X 36" (4) Typ. 109 1/2" Case 30 1/2"
|
|
|
+ EA Damper Duct Receiving 102 7/8" 106" Overall
|
|
|
+ Location Flange OA EA Outlet
|
|
|
+ Lifting Lugs 83" Case
|
|
|
+ (Optional) FA Outlet
|
|
|
+ (RTH, RTR)
|
|
|
+ EA 15 7/8" X 21 3/4"
|
|
|
+ Duct Receiving
|
|
|
+ Flange
|
|
|
+ RA RARTH, RTF EA
|
|
|
+ FA ONLY
|
|
|
+ FA Power/Control
|
|
|
+ 22" FARTH, RTR Wiring Entries
|
|
|
+ 10 1/4"ONLY
|
|
|
+ 7/8 Typ.
|
|
|
+ RA
|
|
|
+ 9 3/8" RA FA
|
|
|
+ 81 5/8" Overall
|
|
|
+ 79 5/8" CaseRTV, RTRRTV, RTF
|
|
|
+ ONLY ONLY
|
|
|
+
|
|
|
+ LEFT VIEW HE6XRT, HE8XRT HE6XRT, HE8XRT FROHE6NXRTT, HVE8XIERTW HE6XRT, HE8XRT RIGHT VIEW
|
|
|
+
|
|
|
+ MDAAroavIaRdiwlaFebiLlnel:OgaHsWsTEhy6oCwpXOneR: N:TFUIGniUt RDAimTIOenNsion OA RTV BACK RTF BACK RTH BACK RTR BACK UNIT MOUNTING & APPLICATION
|
|
|
+ EA OA EA OA EA Must be mounted as shown. Airstreams can not
|
|
|
+ OA EA be switched.
|
|
|
+ RA FA FA
|
|
|
+ Version: AUG18 RA FRONT FRONT
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 8XIN Energy Recovery Ventilator For safety listed products,
|
|
|
+ Standarrdd & Bypass Economizer Option see LE-SERIES models.
|
|
|
+INDOOR UNIT
|
|
|
+ SPECIFICATIONS
|
|
|
+Download specification at:
|
|
|
+renewaire.com/specifications Ventilation Type: Options:
|
|
|
+ Static plate, heat and humidity transfer Onboard variable frequency drives (VFDs) -
|
|
|
+
|
|
|
+ Typical Airflow Range: 2,000-7,950 CFM one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ AHRI 1060 Certified Core: Fused disconnect
|
|
|
+ Eight L125-G5 Integrated programmable controls -
|
|
|
+
|
|
|
+ Standard Features: enhanced, premium
|
|
|
+ TEFC Premium efficiency motors Bypass economizer damper
|
|
|
+ Motor starters
|
|
|
+ Non-fused disconnect (see bypass DIM drawing) -
|
|
|
+ 24 VAC transformer/relay package dry-bulb temperature controls (standard),
|
|
|
+ Cross-core differential pressure ports enthalpy controls (option)
|
|
|
+ Class 1 low leakage motorized isolation dampers -
|
|
|
+ Filters: OA, EA or both airstreams
|
|
|
+ Total qty. 16, MERV 8: 20" x 20" x 2" Qty. 2, Factory mounted filter alarms -
|
|
|
+ both airstreams
|
|
|
+ Unit Dimensions & Weight: Double wall construction
|
|
|
+ 88" L x 113 1/2" W x 81 3/4" H Exterior paint - white, custom colors
|
|
|
+ 2,261-3,278 lbs., varies by option(s)
|
|
|
+ Accessories:
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 116" L x 90" W x 90" H Digital time clock - wall mount (TC7D-W),
|
|
|
+ 3,618 lbs.
|
|
|
+ in exterior enclosure (TC7D-E)
|
|
|
+ Motor(s): Carbon dioxide sensor/control -
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ with adjustable sheaves (see table below) IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+ Sheave External Static Pressure (in. w.g.)
|
|
|
+ Adj.
|
|
|
+Motor HP Blower Turns 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00
|
|
|
+ RPM Open CFM BHP CFM BHP
|
|
|
+ 5575 3.2 3625 2.7
|
|
|
+ 4.5 6200 4.3 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 4625 3.9
|
|
|
+ 2 6650 5.2 5250 4.9
|
|
|
+ 1460 0 6000 3.9 5425 3.2 Th5e2r0m0 al P3e.2rform50a0n0ce R3a.t2ings4G775520135..12.xls4x550 3.0 4270 2.9 8 C4o0r0e0s (IO2M.8) 4300 3.5
|
|
|
+ 4.5 6700 5.3 6010 4.3 5875 4.2 5700 4.2 5500 4.2 5325 4.1 5125 4.1 4900 4.0 5325 5.1
|
|
|
+5.0 1610 2 7225 7.6 6000 7.3
|
|
|
+ 0 7000 6.1 5875 5.8
|
|
|
+ 1725 4.5 7850 8.3 6500 5.2 6375 5.2 6200 5.2 6050 5.1 5875 5.1 5700 5.1 5490 5.0 6775 8.0
|
|
|
+ 2 7150 8.9
|
|
|
+ 1560 1 5850 3.9 5650 3.8 5475 3.8 5275 3.8 5100 3.7 4875 3.7 4600 3.6
|
|
|
+
|
|
|
+7.5 1740 6575 5.3 6400 5.3 6300 5.3 6125 5.3 5950 5.2 5750 5.2 5575 5.1
|
|
|
+
|
|
|
+ 1865 7075 7.6 6950 7.6 6800 7.5 6675 7.5 6500 7.5 6375 7.4 6200 7.4
|
|
|
+
|
|
|
+ 1810 6875 6.1 6750 6.1 6600 6.0 6425 6.0 6275 6.0 6100 5.9 5925 5.8
|
|
|
+
|
|
|
+10.0 2020 7745 8.3 7625 8.2 7450 8.2 7350 8.2 7200 8.1 7050 8.1 6925 8.0
|
|
|
+
|
|
|
+ 2105 7950 9.1 7800 9.1 7725 9.1 7600 9.0 7450 9.0 7300 8.9
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+ FLA Max. FLA Min. Cir. Max. 2000 4000 6000 8000
|
|
|
+ per motor Min. Cir. Overcurrent per motor Amps Overcurrent 90%
|
|
|
+HP Volts HZ Phase Amps Protection Protection Effectiveness (%)
|
|
|
+ 14.5-13.4
|
|
|
+ 208-230 60 Three 6.7 Device Device
|
|
|
+5.0 460 60 Three 5.3
|
|
|
+ Three 32.6 45 14.5-13.4 35.9 45 70%
|
|
|
+ 575 60 21.0-19.0
|
|
|
+ Three 9.5 15.1 20 6.7 16.6 20
|
|
|
+ 208-230 60 Three 7.6
|
|
|
+7.5 460 60 Three 11.9 15 5.3 13.1 15 50%
|
|
|
+ 27.0-25.0
|
|
|
+ 575 60 Three 12.5 47.3 60 21.0-19.0 52.0 60
|
|
|
+ Three 9.76
|
|
|
+ 208-230 60 Three 21.4 25 9.5 23.5 25 30%
|
|
|
+10.0 460 60 At AHRI 1060 standard conditions.
|
|
|
+ 17.1 20 7.6 18.8 20 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+ 575 60
|
|
|
+ 60.8 80 27.0-25.0 66.8 80
|
|
|
+
|
|
|
+ 28.1 35 12.5 30.9 35
|
|
|
+
|
|
|
+ 22.0 30 9.76 24.2 30
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+114 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE8XIN Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ OA34 3/4" ABBREVIATIONS
|
|
|
+ RA Minimum EA: Exhaust Air to outside
|
|
|
+ Service Area OA: Outside Air intake
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 115 RA: Room Air to be exhausted
|
|
|
+ 34 3/4" Minimum Area Door FA: Fresh Air to inside
|
|
|
+ Service Swing INSTALLATION ORIENTATION
|
|
|
+ Unit must be installed in orientation
|
|
|
+ FA EA E-Box shown.
|
|
|
+ Minimum NOTE
|
|
|
+ 62" Service Area 1.ALL UNITS HAVE INTERNAL EA
|
|
|
+ BACKDRAFT DAMPER.
|
|
|
+ 69 1/4" UNLESS AN EA MOTORIZED ISOLATION
|
|
|
+ DAMPER IS SPECIFIED.
|
|
|
+ 2.UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 3.SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 39 1/4" Door Door
|
|
|
+ Minimum Swing Swing
|
|
|
+ Service
|
|
|
+
|
|
|
+ Area
|
|
|
+
|
|
|
+Pressure FA Blower Outlet is 16" X 22" (Nom.) 85 5/8" 36" 24" X 36"
|
|
|
+Ports 24"X36" Duct Receiving Flange is Minimum Duct Receiving
|
|
|
+(4) Typ. also supplied. Field install only in Service Area Power and Control Wiring Flange Typ.
|
|
|
+ location shown. Entries 7/8" Dia.
|
|
|
+ 113" Overall TOP VIEW 85 5/8" Case
|
|
|
+ 112 1/2" Case INDOOR UNITS: EA BLOWER Outlet is
|
|
|
+ 86 1/2" Overall 16" X 22" (Nom.) 24"X36" Duct Receiving
|
|
|
+ 75 7/8" Lift Lugs Flange is also supplied. Field install only in
|
|
|
+
|
|
|
+ location shown.
|
|
|
+
|
|
|
+ Core 78 1/4" Case
|
|
|
+Access 81 5/8" Overall
|
|
|
+
|
|
|
+ Door
|
|
|
+
|
|
|
+ 53 1/2"
|
|
|
+
|
|
|
+2 1/4" 63 1/4" 10 1/4" 81" 63 1/4" 8 3/4"22" Typ.
|
|
|
+ 76 1/2" 108" 49 5/8"
|
|
|
+ FRONT VIEW Internal EA Motorized
|
|
|
+ LEFT VIEW Damper Location (Optional) Internal OA Damper
|
|
|
+MDAArovaIaRdiwlaFebiLlnel:OagHsWsTEhyo8CwpXOneIiNNn:dFUimIGneniUtsiRoDnAidmTraIwOeinnNgs. ion Location (Optional)
|
|
|
+Version: AUG18 RIGHT VIEW
|
|
|
+ BACK VIEW
|
|
|
+
|
|
|
+ UNIT MOUNTING & APPLICATION
|
|
|
+ Must be mounted as shown. Airstreams can not
|
|
|
+ be switched.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 8XIN Energy Recovery Ventilator For safety listed products,
|
|
|
+ Standard with Bypass Economizer see LE-SERIES models.
|
|
|
+INDOOR UNIT
|
|
|
+ SPECIFICATIONS
|
|
|
+Download specification at:
|
|
|
+renewaire.com/specifications Ventilation Type: Options:
|
|
|
+ Static plate, heat and humidity transfer Onboard variable frequency drives (VFDs) -
|
|
|
+
|
|
|
+ Typical Airflow Range: 2,000-7,950 CFM one or both airstreams
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ AHRI 1060 Certified Core: Fused disconnect
|
|
|
+ Eight L125-G5 Integrated programmable controls -
|
|
|
+
|
|
|
+ Standard Features: enhanced, premium
|
|
|
+ TEFC Premium efficiency motors Bypass economizer damper
|
|
|
+ Motor starters
|
|
|
+ Non-fused disconnect (see bypass DIM drawing) -
|
|
|
+ 24 VAC transformer/relay package dry-bulb temperature controls (standard),
|
|
|
+ Cross-core differential pressure ports enthalpy controls (option)
|
|
|
+ Class 1 low leakage motorized isolation dampers -
|
|
|
+ Filters: OA, EA or both airstreams
|
|
|
+ Total qty. 16, MERV 8: 20" x 20" x 2" Qty. 2, Factory mounted filter alarms -
|
|
|
+ both airstreams
|
|
|
+ Unit Dimensions & Weight: Double wall construction
|
|
|
+ 88" L x 113 1/2" W x 81 3/4" H Exterior paint - white, custom colors
|
|
|
+ 2,261-3,278 lbs., varies by option(s)
|
|
|
+ Accessories:
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Filters - MERV 13, 2" (shipped loose)
|
|
|
+ 116" L x 90" W x 90" H Digital time clock - wall mount (TC7D-W),
|
|
|
+ 3,618 lbs.
|
|
|
+ in exterior enclosure (TC7D-E)
|
|
|
+ Motor(s): Carbon dioxide sensor/control -
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ with adjustable sheaves (see table below) IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+AIRFLOW PERFORMANCE
|
|
|
+
|
|
|
+ Sheave External Static Pressure (in. w.g.)
|
|
|
+ Adj.
|
|
|
+Motor HP Blower Turns 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00
|
|
|
+ RPM Open CFM BHP CFM BHP
|
|
|
+ 5575 3.2 3625 2.7
|
|
|
+ 4.5 6200 4.3 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 4625 3.9
|
|
|
+ 2 6650 5.2 5250 4.9
|
|
|
+ 1460 0 6000 3.9 5425 3.2 Th5e2r0m0 al P3e.2rform50a0n0ce R3a.t2ings4G775520135..12.xls4x550 3.0 4270 2.9 8 C4o0r0e0s (IO2M.8) 4300 3.5
|
|
|
+ 4.5 6700 5.3 6010 4.3 5875 4.2 5700 4.2 5500 4.2 5325 4.1 5125 4.1 4900 4.0 5325 5.1
|
|
|
+5.0 1610 2 7225 7.6 6000 7.3
|
|
|
+ 0 7000 6.1 5875 5.8
|
|
|
+ 1725 4.5 7850 8.3 6500 5.2 6375 5.2 6200 5.2 6050 5.1 5875 5.1 5700 5.1 5490 5.0 6775 8.0
|
|
|
+ 2 7150 8.9
|
|
|
+ 1560 1 5850 3.9 5650 3.8 5475 3.8 5275 3.8 5100 3.7 4875 3.7 4600 3.6
|
|
|
+
|
|
|
+7.5 1740 6575 5.3 6400 5.3 6300 5.3 6125 5.3 5950 5.2 5750 5.2 5575 5.1
|
|
|
+
|
|
|
+ 1865 7075 7.6 6950 7.6 6800 7.5 6675 7.5 6500 7.5 6375 7.4 6200 7.4
|
|
|
+
|
|
|
+ 1810 6875 6.1 6750 6.1 6600 6.0 6425 6.0 6275 6.0 6100 5.9 5925 5.8
|
|
|
+
|
|
|
+10.0 2020 7745 8.3 7625 8.2 7450 8.2 7350 8.2 7200 8.1 7050 8.1 6925 8.0
|
|
|
+
|
|
|
+ 2105 7950 9.1 7800 9.1 7725 9.1 7600 9.0 7450 9.0 7300 8.9
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+ FLA Max. FLA Min. Cir. Max. 2000 4000 6000 8000
|
|
|
+ per motor Min. Cir. Overcurrent per motor Amps Overcurrent 90%
|
|
|
+HP Volts HZ Phase Amps Protection Protection Effectiveness (%)
|
|
|
+ 14.5-13.4
|
|
|
+ 208-230 60 Three 6.7 Device Device
|
|
|
+5.0 460 60 Three 5.3
|
|
|
+ Three 32.6 45 14.5-13.4 35.9 45 70%
|
|
|
+ 575 60 21.0-19.0
|
|
|
+ Three 9.5 15.1 20 6.7 16.6 20
|
|
|
+ 208-230 60 Three 7.6
|
|
|
+7.5 460 60 Three 11.9 15 5.3 13.1 15 50%
|
|
|
+ 27.0-25.0
|
|
|
+ 575 60 Three 12.5 47.3 60 21.0-19.0 52.0 60
|
|
|
+ Three 9.76
|
|
|
+ 208-230 60 Three 21.4 25 9.5 23.5 25 30%
|
|
|
+10.0 460 60 At AHRI 1060 standard conditions.
|
|
|
+ 17.1 20 7.6 18.8 20 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+ 575 60
|
|
|
+ 60.8 80 27.0-25.0 66.8 80
|
|
|
+
|
|
|
+ 28.1 35 12.5 30.9 35
|
|
|
+
|
|
|
+ 22.0 30 9.76 24.2 30
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+116 RENEWAIRE.COM 1.800.627.4499
|
|
|
+HE8XIN Energy Recovery Ventilator Standard with Bypass Economizer
|
|
|
+
|
|
|
+ ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ BP: Bypass Air Intake
|
|
|
+ BP34 3/4"
|
|
|
+ Minimum INSTALLATION ORIENTATION
|
|
|
+ OAService Area Unit must be installed in orientation shown.
|
|
|
+ RA
|
|
|
+ 16" X 38" Bypass Duct Connection 34 3/4" Minimum Area 16" X 38" Bypass NOTE
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 117(Direct Mount to Damper, By Others)Service Damper Location 1.ALL UNITS HAVE INTERNAL EA BACKDRAFT DAMPER.
|
|
|
+ UNLESS AN EA MOTORIZED ISOLATION DAMPER IS
|
|
|
+Bypass BP Door Optional 112 5/8" Case SPECIFIED.
|
|
|
+ Swing 116 3/4" Overall 2.UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE
|
|
|
+ 5 1/8" ROUNDED TO THE NEAREST EIGHTH OF AN INCH.
|
|
|
+Damper 3.SPECIFICATIONS MAY BE SUBJECT TO CHANGE
|
|
|
+ EA WITHOUT NOTICE.
|
|
|
+ FA
|
|
|
+
|
|
|
+EA RA 62"
|
|
|
+
|
|
|
+ Face Damper 4. DAMPER SWINGS IN DIRECTION OF AIRFLOW. MIN.
|
|
|
+ DUCT CLEARANCE FROM DAMPER BLADE WHEN
|
|
|
+BYPASS AIRFLOW SCHEMATIC FULLY OPENED TO BE 2". SMACNA RULES APPLY.
|
|
|
+
|
|
|
+ RIGHT VIEW 39 1/4" 32 3/8" Door Door 69 1/4" 5. UNITS WITH BYPASS WILL REQUIRE ADDITIONAL
|
|
|
+ (OA/FA Airstream Not Shown) Minimum Swing Swing SPACE FOR THE CONNECTION OF THE BYPASS DUCT
|
|
|
+ Service (BY OTHERS).
|
|
|
+ FA Blower Outlet is 16" X 22" (Nom.)
|
|
|
+ 24" X 36" Duct Flange is also supplied. Area
|
|
|
+
|
|
|
+ Field install only in location shown. 6. FOR INSTALLATION DETAILS, REFER TO I&O
|
|
|
+ 102 7/8" Lifting Lugs MANUAL SUPPLEMENT FOR BYPASS.
|
|
|
+ 85 5/8" E-Box
|
|
|
+ Minimum Minimum
|
|
|
+ Service Area 36" Service Area
|
|
|
+
|
|
|
+ TOP VIEW 26" X 38" RA Face
|
|
|
+
|
|
|
+ 6 3/8" Typ. 86 5/8" Overall Power and Control Wiring Damper Location
|
|
|
+ 85 5/8" Case Entries 7/8" Dia. Optional
|
|
|
+
|
|
|
+5" Typ. 75 7/8" Lifting Lugs INDOOR UNITS: EA BLOWER Outlet is OA Duct
|
|
|
+ 16" X 22" (Nom.) 24"X36" Duct Flange Flange
|
|
|
+ is also supplied. Field install only in 24" X 36"
|
|
|
+ location shown.
|
|
|
+
|
|
|
+ 2"
|
|
|
+
|
|
|
+ Core 78 1/4" Case 53 1/2"
|
|
|
+ Access 83 3/8" Overall 22"
|
|
|
+
|
|
|
+ Door 21 1/8"
|
|
|
+
|
|
|
+Pressure Ports
|
|
|
+(4) Typ.
|
|
|
+
|
|
|
+ 6 3/8"
|
|
|
+ Typ.
|
|
|
+
|
|
|
+ 63 1/4" 81" 63 1/4" 8 3/4"
|
|
|
+ 48 3/4"
|
|
|
+ 2 1/4" 4" 108" Internal OA Damper
|
|
|
+ 10 1/2" Internal EA Motorized Location (Optional)
|
|
|
+ Damper Location (Optional)
|
|
|
+ LEFT VIEW FRONT VIEW BACK VIEW
|
|
|
+MAoIRdFeLl:OHWE8CXIONN[BFyIGpUaRssA]TION RIGHT VIEW
|
|
|
+DAravawilabinlegasTsyhpowen:inUdnimitenDsiiomn deranwsiinog.n UNIT MOUNTING & APPLICATION
|
|
|
+Version: AUG18 Must be mounted as shown. Airstreams can not
|
|
|
+ be switched.
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HE 8XRT Energy Recovery Ventilator For safety listed products,
|
|
|
+ Standard see LE-SERIES models.
|
|
|
+ROOFTOP UNIT
|
|
|
+ SPECIFICATIONS Options:
|
|
|
+Download specification at: Onboard variable frequency drives (VFDs) -
|
|
|
+renewaire.com/specifications Ventilation Type:
|
|
|
+ Static plate, heat and humidity transfer one or both airstreams
|
|
|
+AIRFLOW PERFORMANCE Shaft grounding ring on motors with VFDs
|
|
|
+ Typical Airflow Range: 2,000-7,950 CFM Fused disconnect
|
|
|
+ Integrated programmable controls -
|
|
|
+ AHRI 1060 Certified Core:
|
|
|
+ Eight L125-G5 enhanced, premium
|
|
|
+ Class 1 low leakage motorized isolation dampers -
|
|
|
+ Standard Features:
|
|
|
+ TEFC Premium efficiency motors OA, EA or both airstreams
|
|
|
+ Motor starters Qty. 2, Factory mounted filter alarms -
|
|
|
+ Non-fused disconnect
|
|
|
+ 24 VAC transformer/relay package both airstreams
|
|
|
+ Cross-core differential pressure ports Double wall construction
|
|
|
+ Exterior paint - white, custom colors
|
|
|
+ Filters:
|
|
|
+ Total qty. 16, MERV 8: 20" x 20" x 2" Accessories:
|
|
|
+ Filters - MERV 13, 2" (shipped loose)
|
|
|
+ Unit Dimensions & Weight: Roof curb - standard 14"
|
|
|
+ 106 1/2" L x 140 1/2" W x 81 3/4" H Curb wind clip
|
|
|
+ 2,399-3,416 lbs., varies by option(s) Engineered combo curb for Carrier RTU
|
|
|
+ Engineered combo curb for Trane RTU
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Digital time clock - wall mount (TC7D-W),
|
|
|
+ Pallet 1 (unit): 116" L x 90" W x 90" H
|
|
|
+ Pallet 2 (hoods): 60" L x 42" W x 90" H in exterior enclosure (TC7D-E)
|
|
|
+ 3,756 lbs. Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ Motor(s): wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ with adjustable sheaves (see table below) duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ Sheave External Static Pressure (in. w.g.)
|
|
|
+ Adj.
|
|
|
+Motor Blower Turns 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00
|
|
|
+ HP RPM Open CFM BHP CFM BHP
|
|
|
+ 5575 3.2 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 3625 2.7
|
|
|
+ 5.0 1460 4.5 6200 4.3 4625 3.9
|
|
|
+ 1610 2 6650 5.2 5425 3.2 Th5e2r0m0 al P3e.2rform50a0n0ce R3a.t2ings4G775520135..12.xls4x550 3.0 4270 2.9 8 C4o0r0e0s (IO2M.8) 5250 4.9
|
|
|
+ 7.5 1725 0 6000 3.9 4300 3.5
|
|
|
+ 1560 4.5 6700 5.3 6010 4.3 5875 4.2 5700 4.2 5500 4.2 5325 4.1 5125 4.1 4900 4.0 5325 5.1
|
|
|
+10.0 1740 2 7225 7.6 6000 7.3
|
|
|
+ 1865 0 7000 6.1 6500 5.2 6375 5.2 6200 5.2 6050 5.1 5875 5.1 5700 5.1 5490 5.0 5875 5.8
|
|
|
+ 1810 4.5 7850 8.3 6775 8.0
|
|
|
+ 2020 2 5850 3.9 5650 3.8 5475 3.8 5275 3.8 5100 3.7 4875 3.7 4600 3.6 7150 8.9
|
|
|
+ 2105 1
|
|
|
+ 6575 5.3 6400 5.3 6300 5.3 6125 5.3 5950 5.2 5750 5.2 5575 5.1
|
|
|
+
|
|
|
+ 7075 7.6 6950 7.6 6800 7.5 6675 7.5 6500 7.5 6375 7.4 6200 7.4
|
|
|
+
|
|
|
+ 6875 6.1 6750 6.1 6600 6.0 6425 6.0 6275 6.0 6100 5.9 5925 5.8
|
|
|
+
|
|
|
+ 7745 8.3 7625 8.2 7450 8.2 7350 8.2 7200 8.1 7050 8.1 6925 8.0
|
|
|
+
|
|
|
+ 7950 9.1 7800 9.1 7725 9.1 7600 9.0 7450 9.0 7300 8.9
|
|
|
+
|
|
|
+Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits.
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+ Standard Electrical Specifications
|
|
|
+ Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+ FLA Min. Max. FLA Min. Cir. Max. 2000 4000 6000 8000
|
|
|
+ per motor Cir. Overcurrent per motor Amps Overcurrent 90%
|
|
|
+HP Volts HZ Phase Amps Protection Protection Effectiveness (%)
|
|
|
+
|
|
|
+ 208-230 Device Device
|
|
|
+5.0 460
|
|
|
+ 60 Three 14.5-13.4 32.6 45 14.5-13.4 35.9 45 70%
|
|
|
+ 575 20
|
|
|
+ 60 Three 6.7 15.1 15 6.7 16.6 20
|
|
|
+ 208-230
|
|
|
+7.5 460 60 Three 5.3 11.9 60 5.3 13.1 15 50%
|
|
|
+ 25
|
|
|
+ 575 60 Three 21.0-19.0 47.3 20 21.0-19.0 52.0 60
|
|
|
+
|
|
|
+ 208-230 60 Three 9.5 21.4 80 9.5 23.5 25 30%
|
|
|
+10.0 460 35 At AHRI 1060 standard conditions.
|
|
|
+ 60 Three 7.6 17.1 30 7.6 18.8 20 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+ 575
|
|
|
+ 60 Three 27.0-25.0 60.8 27.0-25.0 66.8 80
|
|
|
+ 60 Three 12.5 28.1
|
|
|
+ 60 Three 9.76 22.0 12.5 30.9 35
|
|
|
+
|
|
|
+ 9.76 24.2 30
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+118 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ HE8XRT Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ 121 1/4" Minimum 39 1/2" ABBREVIATIONS
|
|
|
+ Service Area EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ 65 3/4" Minimum Door Door FA (RTV, RTF) CURB 8X RA: Room Air to be exhausted
|
|
|
+ Service Area Swing Swing 16" X 22" FA: Fresh Air to inside
|
|
|
+ 76" O.D. RTV: Rooftop Vertical RA & FA
|
|
|
+ 15 3/4" 36" RTF: Rooftop Vertical FA Only
|
|
|
+ 135 3/4" Minimum RTR: Rooftop Vertical RA Only
|
|
|
+ Service Area RTH: Rooftop Horizontal RA & FA
|
|
|
+
|
|
|
+ 26 1/4" 99 1/4" I.D. 26" INSTALLATION ORIENTATION
|
|
|
+ Unit must be installed in orientation
|
|
|
+ shown.
|
|
|
+
|
|
|
+ FA NOTE:
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ 71 1/2" Door 31" 103" O.D. DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ Swing NEAREST EIGHTH OF AN INCH.
|
|
|
+
|
|
|
+ A A 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ RA TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 36" CURB CROSS-SECTION A-A (TYP.)
|
|
|
+ 72 1/4" I.D.
|
|
|
+ 19 7/8" 20" Minimum 26" 1 1/2" X 1/4" 1 7/8"
|
|
|
+ Service Area TOP VIEW Neoprene Gasket
|
|
|
+ 54 7/8"
|
|
|
+ 60 7/8" RA (RTV, RTR) 140 1/8" Overall 3/4" X 3 1/2"
|
|
|
+ 24" X 34" 109 1/2" Case Wooden Nailer
|
|
|
+ TOP VIEW 102 7/8"
|
|
|
+ Lifting Lugs 3" 14"
|
|
|
+
|
|
|
+ SECTION A-A
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 119 OA Damper OA Inlet Pressure 1 1/4" Disconnect
|
|
|
+ Location Ports Typ. Switch
|
|
|
+ (4) Typ. 30 1/2" 81 5/8" Overall
|
|
|
+ (Optional) EA Outlet 79 5/8" Case 106" Overall
|
|
|
+ EA Damper RA Inlet 83" Case
|
|
|
+ (RTH, RTF) FA Outlet
|
|
|
+ Location 24" X 36" (RTH, RTR) EA
|
|
|
+ (Optional) 15 7/8" X 21 3/4"
|
|
|
+ Duct Receiving OA Duct Receiving Power/Control
|
|
|
+ EA Flange Wiring Entries
|
|
|
+ Flange
|
|
|
+ 7/8 Typ.
|
|
|
+ FARTH, RTR RARTH, RTF
|
|
|
+ ONLY ONLY
|
|
|
+
|
|
|
+ 22"
|
|
|
+
|
|
|
+ 9 3/8" RA FA
|
|
|
+
|
|
|
+ RTV, RTR RTV, RTF 10 1/4"
|
|
|
+ ONLY ONLY
|
|
|
+
|
|
|
+ HE6XRT, HE8XRT HE6XRT, HE8XRT HE6XRT, HE8XRT HE6XRT, HE8XRT
|
|
|
+
|
|
|
+ LEFT VIEW FRONT VIEW RIGHT VIEW
|
|
|
+ AIRFLOW CONFIGURATION
|
|
|
+ RTV BACK RTF BACK RTH RTR BACK UNIT MOUNTING & APPLICATION
|
|
|
+ MoAdvaeilalb:leHaEs 8shXowRnTin dimension drawing. BACK OA EA Must be mounted as shown. Airstreams can not
|
|
|
+ Drawing Type: Unit Dimension be switched.
|
|
|
+ Version: AUG18 OA EA OA EA OA EA FA
|
|
|
+ FRONT
|
|
|
+ RA RA FA
|
|
|
+
|
|
|
+ FRONT
|
|
|
+
|
|
|
+ RA RA
|
|
|
+ FA
|
|
|
+ FA
|
|
|
+
|
|
|
+ HE-SERIES
|
|
|
+ T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
|
|
|
+
|
|
|
+120 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+OPTIONS
|
|
|
+
|
|
|
+See individual submittal pages for availability by model.
|
|
|
+
|
|
|
+EC MOTOR u Easy airflow setup using RenewAire’s
|
|
|
+ standard pressure taps
|
|
|
+u Best energy efficiency - cuts commissioning time
|
|
|
+u Two speed, single speed, or variable
|
|
|
+
|
|
|
+ speed operation
|
|
|
+
|
|
|
+ELECTRICAL u Independent blower control (IBC)
|
|
|
+u Disconnect fuses and motor starters available as an option for HE1X and
|
|
|
+ HE1.5X
|
|
|
+
|
|
|
+VARIABLE FREQUENCY DRIVE
|
|
|
+
|
|
|
+u Factory supplied and mounted variable u Pre-programmed speeds or variable
|
|
|
+ frequency drives (VFDs) speed
|
|
|
+ - one or both airstreams
|
|
|
+ u Easy airflow setup using RenewAire’s
|
|
|
+u Provides additional control options standard pressure ports
|
|
|
+ - cuts commissioning time
|
|
|
+u Separate VFD for each airstream
|
|
|
+ u Shaft grounding ring on motors with
|
|
|
+u Display/control in electrical box - can be VFDs
|
|
|
+ remotely mounted
|
|
|
+
|
|
|
+ VFD all voltage VFD
|
|
|
+ except 575V 575V only
|
|
|
+
|
|
|
+MOTORIZED ISOLATION DAMPERS
|
|
|
+
|
|
|
+u Class 1, low leakage u Damper(s) are factory mounted and
|
|
|
+ wired (except in HE1XIN - shipped
|
|
|
+u Robust, reliable actuators for highest loose)
|
|
|
+ dependability
|
|
|
+
|
|
|
+u Automatic operation with spring return in
|
|
|
+ event of power loss
|
|
|
+
|
|
|
+FILTER ALARM u Allows for remote indication of loaded
|
|
|
+ (dirty) filter
|
|
|
+u Factory mounted airflow switches - one
|
|
|
+ for each airstream
|
|
|
+
|
|
|
+EXTERIOR PAINT
|
|
|
+u White and custom colors available
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 121
|
|
|
+OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+OPTIONS
|
|
|
+
|
|
|
+Bypass Economizer
|
|
|
+
|
|
|
+AVAILABLE ON ALL HE-SERIES INDOOR UNITS
|
|
|
+
|
|
|
+By utilizing what nature offers, our bypass economizer can “free cool” indoor spaces by using tempered and filtered
|
|
|
+outdoor air when the temperature and/or humidity are within a favorable range. This process M A X I M I Z E S
|
|
|
+O P E R AT I N G E F F I C I E N C I E S and R E D U C E S E N E R G Y use and costs, all
|
|
|
+while indoor air quality is Enhanced—a win-win for occupant health, the environment and the bottom line. Bypass
|
|
|
+can now be specified for all RenewAire HE indoor units as a factory option.
|
|
|
+
|
|
|
+KEY BENEFITS
|
|
|
+
|
|
|
+u Reduce energy use and costs: u Ultimate reliability:
|
|
|
+ Energy efficiency is optimized since the bypass provides airside Our commitment to innovative design practices, expert
|
|
|
+ economizer capabilities to the building mechanical system. workmanship and Quick Response Manufacturing ensures
|
|
|
+ unmatched reliability.
|
|
|
+u Flexible design:
|
|
|
+ Bypass allows for flexibility in the routing of the bypass duct. u Fast and easy implementation:
|
|
|
+ Additionally, the dampers are adjustable and AMCA Class I The economizer option doesn’t affect the current lead time of the
|
|
|
+ certified for low leakage. base units, and it doesn’t require any additional certifications.
|
|
|
+
|
|
|
+u Increase installation opportunities: u Meet code requirements:
|
|
|
+ HE indoor units can now be specified and installed on projects Bypass helps HE indoor units meet economizer requirements per
|
|
|
+ that require ERV bypass. building codes and other referenced standards.
|
|
|
+
|
|
|
+u 100% bypass of air:
|
|
|
+ Unlike other options on the market, RenewAire offers 100% core
|
|
|
+ bypass of air, resulting in free cooling and further energy reductions.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+122 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+OPTIONS
|
|
|
+
|
|
|
+Bypass Economizer
|
|
|
+
|
|
|
+The bypass system consists of the addition of an extra bypass duct, two electrically actuated dampers and a control system. Bypass
|
|
|
+is achieved with the help of two dampers consisting of the face damper (normally closed) and the bypass damper (normally closed),
|
|
|
+factory-installed bypass controls and field-installed ductwork that links the return air to the exhaust air. When conditions are favorable
|
|
|
+for bypass, the face damper closes while the bypass damper opens simultaneously, thereby allowing for 100% of the return air to
|
|
|
+bypass the core. The Bypass Economizer option comes with two factory-supplied dampers and a bypass control system of your choice:
|
|
|
+
|
|
|
+DAMPERS CONTROLS
|
|
|
+
|
|
|
+ The face damper is factory-installed on Dry-bulb control:
|
|
|
+ the return air (RA) duct inlet for all units The standard bypass control is temperature-
|
|
|
+ except HE1X. The bypass damper is also based via a single outdoor-air controller
|
|
|
+ factory-installed on all units except HE1X and sensor.
|
|
|
+ and HE1.5X.
|
|
|
+
|
|
|
+ Square Damper Enthalpy control:
|
|
|
+ This optional bypass control is based on
|
|
|
+ Circle Damper differential enthalpy and uses a return-air
|
|
|
+FIELD-INSTALLED BYPASS DUCT SIZE RECOMMENDATIONS enthalpy sensor in conjunction with an
|
|
|
+ outdoor-air enthalpy controller and a
|
|
|
+ dry-bulb temperature controller.
|
|
|
+
|
|
|
+ ERV UNIT FACE DAMPER BYPASS DAMPER RECOMMENDED BYPASS
|
|
|
+ DUCT SIZE*
|
|
|
+
|
|
|
+ HE1XINH, HE1XINV Shipped loose Shipped loose 12"
|
|
|
+HE1.5XINH, HE1.5XINV Factory installed Shipped loose 12"
|
|
|
+ Factory installed Factory installed 16" x 16"
|
|
|
+ HE2XINH, HE2XINV Factory installed Factory installed 30" x 16"
|
|
|
+ HE3XINH 36" x 14"
|
|
|
+ HE3XINV Factory installed Factory installed 34" x 16"
|
|
|
+ HE4XINH Factory installed Factory installed 42" x 14"
|
|
|
+ HE4XINV 38" x 16"
|
|
|
+
|
|
|
+ HE6XIN, HE8XIN
|
|
|
+
|
|
|
+* Recommended duct sizes are based on ensuring that the pressure drop in the bypass duct is less than the pressure drop through the core. Equivalent duct sizes at same
|
|
|
+ pressure drop are acceptable.
|
|
|
+
|
|
|
+NOTE: Installation of bypass duct per SMACNA guidelines.
|
|
|
+
|
|
|
+100% ECONOMIZER PARTIAL ECONOMIZER
|
|
|
+
|
|
|
+ VRF/ The Bypass Economizer RELIEF DAMPER When connected to a
|
|
|
+ CHILLED option will provide 100% OPENS DURING main building air handler,
|
|
|
+ WATER/ economizer capabilities ECONOMIZER the Bypass Economizer
|
|
|
+HOT WATER option shall offer partial
|
|
|
+ OPERATION bypass of only the ERV
|
|
|
+ total airflow. For 100%
|
|
|
+ BYPASS RA CEILING in mechanical systems MECHANICAL ROOM CEILING economizer capability on the
|
|
|
+ where the ERV is 8,000 CFM ROOM HVAC system, the air handler
|
|
|
+ 1500 CFM 1500 RA DUCT connected to a fan coil must be equipped with either
|
|
|
+ NOT SHOWN unit or supplying fresh air powered relief or barometric
|
|
|
+OA CFM directly into the space. relief economizer capacity
|
|
|
+ Examples of such systems (barometric relief shown).
|
|
|
+ BYPASS
|
|
|
+
|
|
|
+EA ERV FA 1500 2,000 CFM
|
|
|
+ 1500 CFM
|
|
|
+ FCU OA HC
|
|
|
+ ROOM FRESH
|
|
|
+ CFM AIR EA ERV
|
|
|
+ 2,000 CFM
|
|
|
+MECHANICAL ROOM AHU
|
|
|
+ 10,000 CFM
|
|
|
+
|
|
|
+ are VRF, Chilled Beam or
|
|
|
+
|
|
|
+ Chilled/Heated Panels.
|
|
|
+
|
|
|
+100% BYPASS ECONOMIZER APPLICATION WITH ERV PARTIAL ECONOMIZER APPLICATION
|
|
|
+ WITH BYPASS-EQUIPPED ERV
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 123
|
|
|
+OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+OPTIONS
|
|
|
+
|
|
|
+Integrated Programmable Controls
|
|
|
+
|
|
|
+AVAILABLE ON ALL EV450, HE, LE, RD AND DN-SERIES UNITS
|
|
|
+
|
|
|
+RenewAire’s I N T E G R AT E D P R O G R A M M A B L E
|
|
|
+C O N T R O L S optimize the usability and performance of our
|
|
|
+commercial ERVs by improving functionality, enabling intelligent
|
|
|
+controls, streamlining operations and boosting efficiencies. This is
|
|
|
+accomplished via sophisticated factory-installed microprocessor
|
|
|
+controls and sensors that provide stand-alone ERVs with Direct Digital
|
|
|
+Control (DDC) and/or Building Management System (BMS) control
|
|
|
+interface.
|
|
|
+
|
|
|
+KEY BENEFITS
|
|
|
+
|
|
|
+Optimize usability: Increase capabilities:
|
|
|
+u Maximize ERV functionality and intelligent control via remote u Expand ERV connectivity via access to a wide range of open
|
|
|
+
|
|
|
+ Ethernet accessibility and BMS connectivity without third-party standard protocols, including BACnet and Modbus.
|
|
|
+ interface.
|
|
|
+ u Broaden ERV interoperability by connecting to third-party
|
|
|
+u Streamline operations by easily managing and changing ERV equipment and receiving third-party signals for unit control.
|
|
|
+ control parameters via an advanced user interface.
|
|
|
+ u Expand ERV-application scope by meeting new code
|
|
|
+u Increase uptime reliability through constant system monitoring. requirements and the needs of institutional customers
|
|
|
+ requiring DDC controls in mechanical equipment.
|
|
|
+u Achieve cleaner and healthier indoor air via IAQ-based ERV control.
|
|
|
+
|
|
|
+Improve performance: Simplify operations:
|
|
|
+u Support effective and efficient ERV performance with real-time u Achieve easier ERV setup, commissioning and balancing via
|
|
|
+
|
|
|
+ data trending and logging capabilities. simple-to-install controls.
|
|
|
+
|
|
|
+u Enhance ERV control via access to real-time airflow rates, u Improve operational efficiencies by easily communicating ERV
|
|
|
+ airstream temperature and airstream humidity. status, airflows, temperatures and humidity.
|
|
|
+
|
|
|
+u Facilitate fast and easy ERV upkeep and maintenance with u Allow for more flexible installations by enabling ERVs to be
|
|
|
+ real-time fan, filter and bypass status. interconnected with a BMS, operated independently or run in
|
|
|
+ concert with other ERVs.
|
|
|
+
|
|
|
+A C C E S S O R I E S AVAILABLE WITH INTEGRATED PROGRAMMABLE CONTROLS
|
|
|
+
|
|
|
+ CO2 sensor (wall or duct mount)* STANDARD ENHANCED PREMIUM
|
|
|
+ IAQ sensor (wall or duct mount)* CONTROLS CONTROLS CONTROLS
|
|
|
+ Occupancy sensor (ceiling or wall mount)
|
|
|
+ Smoke detector (duct mount) u u u
|
|
|
+ BACnet factory activation (MS/TP or TCP/IP) u u u
|
|
|
+ Remote display (handheld or wall mount) u u u
|
|
|
+ Room Pressure Sensor (with or without display) u u
|
|
|
+ Duct Static Pressure Sensor (with or without display) u
|
|
|
+ Temperature Sensor Kit (wall or duct mount)** u
|
|
|
+ u
|
|
|
+NOTES u
|
|
|
+ u
|
|
|
+*Sensor output is 0-10 vdc, for use as on/off or modulating control.
|
|
|
+**Temperature Sensor Kit is for use with non-integrated heating.
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+124 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+OPTIONS
|
|
|
+
|
|
|
+Integrated Programmable Controls
|
|
|
+
|
|
|
+MODELS FEATURE COMPARISON
|
|
|
+
|
|
|
+STANDARD CONTROLS STANDARD
|
|
|
+ CONTROLS
|
|
|
+via dry contact and relays ENHANCED
|
|
|
+Our ERV units are provided with a dry contact CONTROLS
|
|
|
+that can be used to control the unit with a variety PREMIUM
|
|
|
+of low-voltage (24VAC) control devices such as CONTROLS
|
|
|
+remote switches or relays. In addition, third-party
|
|
|
+analog output can be used to operate the ERV. Ability to automatically enable and disable unit u u u
|
|
|
+
|
|
|
+ENHANCED CONTROLS Enable the exhaust fan only (See note 1) u u u
|
|
|
+
|
|
|
+Carel [c.pCOMini] with or without BACnet Filter alarm for both sets of filters (See note 2) u u u
|
|
|
+Enhanced controls offer automated control,
|
|
|
+including temperature and humidity control with Bypass controls† (See note 3) u u u
|
|
|
+data trending via microprocessor controls and
|
|
|
+sensors that enable BMS connectivity. Control isolation dampers† (See note 4) u u u
|
|
|
+
|
|
|
+PREMIUM CONTROLS Supply fan only modulation for VFD/EC Motor units† u u u
|
|
|
+
|
|
|
+Carel [c.pCOMini] with expansion module (See note 5 and 6) u u u
|
|
|
+with or without BACnet
|
|
|
+Premium controls include all functionality of Exhaust fan only modulation for VFD/EC Motor units† u u u
|
|
|
+Enhanced-controls capabilities, as well as
|
|
|
+airflow and IAQ monitoring, demand control, (See note 5 and 6)
|
|
|
+electric or gas heating options, as well as
|
|
|
+RD-Series cooling and heating control. Internal time clock (See note 7)
|
|
|
+
|
|
|
+ Defrost controls - Canada only u u u
|
|
|
+
|
|
|
+ Smoke detection - sensor required (See note 8) u u u
|
|
|
+
|
|
|
+ Demand control ventilation using CO2 - sensor required u u
|
|
|
+
|
|
|
+ Occupancy-based ventilation - sensor required u u
|
|
|
+
|
|
|
+ IAQ control ventilation using VOC - sensor required u u
|
|
|
+
|
|
|
+ Microprocessor controller u u
|
|
|
+
|
|
|
+ Provide supply and exhaust air temperatures u u
|
|
|
+
|
|
|
+ Provide outside and return air temperature and humidity† u u
|
|
|
+
|
|
|
+ Fan status on both fans†† u u
|
|
|
+
|
|
|
+ Enable the supply fan only† u u u
|
|
|
+
|
|
|
+ Enable the exhaust fan only† u u u
|
|
|
+
|
|
|
+ Micro USB port u u
|
|
|
+
|
|
|
+ Fieldbus port u u
|
|
|
+
|
|
|
+ BACnet MS/TP or BACnet TCP/IP - activation required u u
|
|
|
+
|
|
|
+ Modbus u u
|
|
|
+
|
|
|
+ Data trending u u
|
|
|
+
|
|
|
+ Outside airflow rate u
|
|
|
+
|
|
|
+ Exhaust airflow rate u
|
|
|
+
|
|
|
+ Space pressure control u
|
|
|
+
|
|
|
+ Duct pressure control u
|
|
|
+
|
|
|
+ Unit supply air temp u
|
|
|
+
|
|
|
+ Heating enable u
|
|
|
+
|
|
|
+ Heating modulation - staged or modulating u
|
|
|
+
|
|
|
+ Cooling modulation* - staged or modulating u
|
|
|
+
|
|
|
+ *RD-Series units only †Not available on EV450 ††EF fan status not available on EV450
|
|
|
+
|
|
|
+ NOTES FOR STANDARD CONTROLS ONLY 5. VFD (option). Factory installed and wired.
|
|
|
+ 6. EC Motor (option) Potentiometer control factory wired.
|
|
|
+ 1. Relays and terminal block (option). 7. Independent time clock (option).
|
|
|
+ 2. Differential pressure sensing tube and pressure switch 8. External smoke detector (option), field installed
|
|
|
+
|
|
|
+ with manual trip point adjustment (option), wiring in series to shut off unit in adverse conditions.
|
|
|
+ to switch and alarm indication provided by others.
|
|
|
+ 3. Option on HE-Series (IN) and standard on RD-Series.
|
|
|
+ 4. 24V transformer contactors and relays (option).
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 125
|
|
|
+OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+ACCESSORIES
|
|
|
+
|
|
|
+Standard Controls
|
|
|
+
|
|
|
+Standard controls are intended to turn RenewAire commercial energy recovery ventilation systems on and off at appropriate times.
|
|
|
+Specification, installation and set-up is an easy process. RenewAire HE, LE, and RD Series units come standard with a 24 volt
|
|
|
+transformer/relay package for easy interface with all controls.
|
|
|
+
|
|
|
+It is not necessary that RenewAire controls be used to operate RenewAire units. A wide range of controls or building automation
|
|
|
+systems may be used.
|
|
|
+
|
|
|
+*Available with Standard or Integrated Programmable Controls.
|
|
|
+**Only available with Integrated Programmable Controls.
|
|
|
+
|
|
|
+DIGITAL TIME CLOCK*
|
|
|
+
|
|
|
+u Up to 8 on/off cycles per day or 56 per u Battery back-up box
|
|
|
+
|
|
|
+week u Wall mount or outdoor enclosure options
|
|
|
+
|
|
|
+u 24 VAC power requirement u Wall mount fits any 4" x 4" electrical
|
|
|
+
|
|
|
+ TC7D-W
|
|
|
+ Wall Mount
|
|
|
+
|
|
|
+ TC7D-E Control In
|
|
|
+ NEMA 3R Enclosures
|
|
|
+
|
|
|
+CO2 SENSORS* u Self calibrates during periods of low
|
|
|
+u Adjustable control from 400-2000 PPM occupancy
|
|
|
+u Digital display
|
|
|
+u 24 VAC power requirement u Wall mount or add duct mount accessory
|
|
|
+u Computer/BAS interface for information and
|
|
|
+ CO2-D
|
|
|
+ control Duct Mount
|
|
|
+
|
|
|
+ CO2-W
|
|
|
+ Wall Mount
|
|
|
+
|
|
|
+IAQ SENSORS* u Selectable 0-5 or 0-10V dc signal
|
|
|
+ u 24 VAC power required
|
|
|
+u Measures TVOC u Internal menu for easy set-up
|
|
|
+u Direct correlation to CO2 levels
|
|
|
+u 0-2000 ppm CO2 equivalent output IAQ-D
|
|
|
+ Duct Mount
|
|
|
+ signal
|
|
|
+u Digital display on wall mount
|
|
|
+
|
|
|
+ IAQ-W
|
|
|
+ Wall Mount
|
|
|
+
|
|
|
+MOTION OCCUPANCY SENSORS*
|
|
|
+
|
|
|
+u Passive infared sensor u Coverage floor space
|
|
|
+u Adjustable time-off delay to 30 minutes
|
|
|
+u 24 VAC power requirement - Ceiling mount: 1500 sq. ft.
|
|
|
+u Ceiling mount or directable wall mount - Wall mount: 2500 sq. ft.
|
|
|
+
|
|
|
+ u Major motion area MC-C MC-W
|
|
|
+ Ceiling Mount Wall Mount
|
|
|
+ - Ceiling mount: 50 ft. diameter
|
|
|
+ - Wall mount: 68 x 50 ft.
|
|
|
+
|
|
|
+SMOKE DETECTOR* u For 100-4000 fpm duct air velocity SD-D
|
|
|
+ applications Duct Mount
|
|
|
+u Photoelectric type detector
|
|
|
+u Plug-in sensor u 24 VAC power requirement
|
|
|
+u Round, square or rectangular duct
|
|
|
+ u Interconnect feature for multi-fan
|
|
|
+ mounting options shutdown
|
|
|
+u Easy access test/reset button and LED
|
|
|
+ u Built-in short circuit protection
|
|
|
+ display
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+126 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+ACCESSORIES
|
|
|
+
|
|
|
+Controls Continued
|
|
|
+
|
|
|
+REMOTE DISPLAY**
|
|
|
+
|
|
|
+u Hand held or wall mount
|
|
|
+u LED display
|
|
|
+u Keypad for easy programming
|
|
|
+
|
|
|
+ RD-M
|
|
|
+ Handheld or Wall Mount
|
|
|
+
|
|
|
+PRESSURE SENSORS (ROOM PRESSURE/DUCT STATIC PRESSURE)**
|
|
|
+
|
|
|
+u With or without display
|
|
|
+
|
|
|
+u Differential pressure transmitter
|
|
|
+
|
|
|
+u 4-20 mA or field selectable 0-10 & 0.5V
|
|
|
+ output signal
|
|
|
+
|
|
|
+u Integral barbed tubing connections that
|
|
|
+ fit 1/8" and 3/16" ID tubing
|
|
|
+
|
|
|
+ RPS-WOD/DPS-WOD RPS-WD/DPS-WD
|
|
|
+ Wall/Duct Mount Wall/Duct Mount
|
|
|
+ without Display
|
|
|
+ with Display
|
|
|
+
|
|
|
+BACNET FACTORY ACTIVATION** BN-A
|
|
|
+
|
|
|
+u Allows for communication to a BAS via
|
|
|
+ Bacnet NS/TP
|
|
|
+
|
|
|
+u Factory programmed and tested
|
|
|
+
|
|
|
+TEMPERATURE SENSOR KIT**
|
|
|
+u Duct temperature sensors
|
|
|
+u Hermetically sealed 304SS probe
|
|
|
+u Operating range -40F to 210F
|
|
|
+u Easy installation with integral
|
|
|
+
|
|
|
+ mounting plate
|
|
|
+
|
|
|
+Engineered Combo Curbs TS
|
|
|
+ Wall/Duct Mount
|
|
|
+Exclusively designed for select Trane (Voyager and Precedent)
|
|
|
+and Carrier (WeatherExpert, WeatherMaster, and Weathermaker) Available Options (Special Order)
|
|
|
+models, RenewAire’s engineered combo curb makes it easy to u Seismic and/or wind load applications
|
|
|
+combine standard Air Handling Unit (AHU) rooftop applications u Pitched roof applications
|
|
|
+with the benefits of RenewAire energy recovery ventilation. u High vibration applications
|
|
|
+They eliminate the need for transitional ductwork between the u Custom curb heights
|
|
|
+RTU and the ERV, reducing the time and costs of installation. u Heavier metal gauges
|
|
|
+Simply install the curb, run the return and supply duct to the u Aluminum liners
|
|
|
+curb openings, then install the AHU and RenewAire units onto the
|
|
|
+curb. Additionally, the curbs allow the AHU unit to function in its
|
|
|
+standard operation as well as full-flow economizer modes.
|
|
|
+
|
|
|
+Standard Construction
|
|
|
+u Prime G-90, 18-gauge galvanized steel
|
|
|
+u Fully welded and mitered corners (single piece curb lift)
|
|
|
+u Base flange attachments for securing to the building structure
|
|
|
+u 1 ½" 3 lb. density fiberglass insulation
|
|
|
+u Reinforced with cross channel supports on center
|
|
|
+u Conforms to ASTM A653/A653M (standard specification for sheet metal)
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 127
|
|
|
+OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+ACCESSORIES
|
|
|
+
|
|
|
+Hoods and Dampers
|
|
|
+
|
|
|
+FA10-G & FA12-G u Hood type wall cap
|
|
|
+u 10" or 12" wall cap u 1/4" metal screen
|
|
|
+u Galvanized finish
|
|
|
+
|
|
|
+FA10-P & FA12-P u Paintable
|
|
|
+u 10" or 12" wall cap u 1/4" metal screen
|
|
|
+u Galvanneal finish
|
|
|
+
|
|
|
+VW12X12 u Flush mount
|
|
|
+u 12" x 12" x 10" round louver u 1/2" metal screen
|
|
|
+u Galvanized finish
|
|
|
+
|
|
|
+BD10 & BD12 u Mechanical “butterfly” design
|
|
|
+u 10", 12" backdraft damper
|
|
|
+u Male/female ends
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+128 RENEWAIRE.COM 1.800.627.4499
|
|
|
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 129
|
|
|
+OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+ACCESSORIES
|
|
|
+
|
|
|
+RH Series Electric Duct Heater
|
|
|
+
|
|
|
+AVA I L A B L E O N S I N G L E / M U LT I - FA M I LY A N D L I G H T C O M M E R C I A L U N I T S ( S O M E E X C E P T I O N S A P P LY )
|
|
|
+
|
|
|
+RenewAire offers the highest-efficiency energy recovery ventilators (ERVs) on the market. However, during winter
|
|
|
+conditions, supply air from the ERV may be less than optimal for space conditions. By adding R E N E W A I R E ’ S
|
|
|
+R O U N D E L E C T R I C D U C T H E AT E R as an option to our single/multi-family and light
|
|
|
+commercial ERVs, RenewAire can now heat supply air during cooler months to enhance indoor comfort, all via one
|
|
|
+package for ERVs and heaters from a single source.
|
|
|
+
|
|
|
+ RH SERIES
|
|
|
+ RH-W SHOWN
|
|
|
+
|
|
|
+KEY BENEFITS u Easy installation: A ZERO clearance rating to combustibles
|
|
|
+ allows designers and contractors to apply RenewAire heaters
|
|
|
+u A single source reduces time and costs: A single with less restrictions onsite.
|
|
|
+ information source, a single purchase point and a single
|
|
|
+ approval package for ERVs and heaters reduces design time u Ultimate reliability: RenewAire heaters come with our two-year
|
|
|
+ and costs, and streamlines logistics for design engineers warranty and unmatched reliability. Single-source responsibility
|
|
|
+ and contractors. offers contractors and end users peace of mind and a single call
|
|
|
+ location for technical, start-up and commissioning questions.
|
|
|
+u More flexibility: RenewAire offers design engineers the
|
|
|
+ capacity to specify ERVs with a matching heater to boost u Highly certified: CSA certified and evaluated to the applicable
|
|
|
+ flexibility and provide heated air to a single space or ANSI/UL and CSA Standards, for use in the U.S. and Canada.
|
|
|
+ multiple spaces.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+130 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+RH SERIES Electric Duct Heater (1-11.5 kW)
|
|
|
+ Accessory
|
|
|
+
|
|
|
+ LR 30551
|
|
|
+
|
|
|
+ELECTRIC DUCT HEATER NEW SPECIFICATIONS
|
|
|
+
|
|
|
+ Heater Type: Standard Features:
|
|
|
+ Electric Duct Heater Open-coil element
|
|
|
+ High grade nickel-chrome element wire
|
|
|
+ Typical KW Range: Thermostat - Integral (RH-D),
|
|
|
+ 1–11.5 kW (1, 2, 3, 4, 5, 6, 8, 10, 11.5 kW)
|
|
|
+ Wall mount (RH-W)
|
|
|
+ Voltages & Phase: Modulating heat output (SCR control)
|
|
|
+ Single phase - 120, 208 and 240V Vertical or horizontal operation
|
|
|
+ Automatic limit switch for primary
|
|
|
+ Control Voltage:
|
|
|
+ 24 VAC over-temperature protection
|
|
|
+ Manual reset limit switch for secondary
|
|
|
+RH-D (Integral Thermostat)
|
|
|
+ over-temperature protection
|
|
|
+ Airflow sensor
|
|
|
+ Standard control transformer - 24 VAC
|
|
|
+ Corrosion resistant galvanized steel
|
|
|
+ Round duct collars
|
|
|
+ High voltage terminal block connections
|
|
|
+ Grounding lug
|
|
|
+ Mounting flanges
|
|
|
+
|
|
|
+ Note: Electric duct heater designed for indoor ductwork installation only.
|
|
|
+
|
|
|
+ Duct Collars kW V Size Width (X) Height (Y) Depth (Z)
|
|
|
+ 6" 11 1/2" 8" 11 1/2"
|
|
|
+ 8" 1, 2 120, 208, 240 A 11 1/2" 10" 13 1/2"
|
|
|
+ 8" 11 1/2" 10" 13 1/2"
|
|
|
+ 10" 3, 4, 5 208 B 11 1/2" 10" 13 1/2"
|
|
|
+ 10" 11 1/2" 10" 13 1/2"
|
|
|
+ 10" 3, 4, 5, 6 240 B 15 1/2" 12" 15 1/2"
|
|
|
+ 12" 15 1/2" 12" 15 1/2"
|
|
|
+ 3, 4, 5 208 B
|
|
|
+
|
|
|
+ 3, 4, 5, 6 240 B
|
|
|
+
|
|
|
+ RH-W (Wall Mount Thermostat) 8, 10, 11.5 240 C
|
|
|
+
|
|
|
+Download specification at: 6, 8, 10, 11.5 240 C
|
|
|
+renewaire.com/specifications
|
|
|
+
|
|
|
+ Y Z DIMENSIONS IN INCHES
|
|
|
+ SIZE X Y Z
|
|
|
+ XA B C
|
|
|
+ A 11.5 8.0 11.5
|
|
|
+ B 11.5 10.0 13.5
|
|
|
+ C 15.5 12.0 15.5
|
|
|
+
|
|
|
+ RH SERIES HEATER CAPACITY
|
|
|
+ RH SERIES HEATER CAPACITY
|
|
|
+ 13
|
|
|
+Minimum Airflow Heater Capacity HEATER CAPACITY - kW
|
|
|
+ (CFM) (kW) 12
|
|
|
+
|
|
|
+ 30 1.00 11
|
|
|
+ 60 2.00
|
|
|
+ 90 3.00 10
|
|
|
+ 120 4.00
|
|
|
+ 150 5.00 9
|
|
|
+ 180 6.00
|
|
|
+ 240 8.00 8
|
|
|
+ 300 10.00
|
|
|
+ 345 11.50 7
|
|
|
+
|
|
|
+ 6 SAFE OPERATING
|
|
|
+ 5
|
|
|
+ RANGE
|
|
|
+ 4
|
|
|
+
|
|
|
+ 3
|
|
|
+
|
|
|
+ 2
|
|
|
+
|
|
|
+ 1
|
|
|
+
|
|
|
+ 0
|
|
|
+
|
|
|
+ 30 60 90 120 150 180 210 240 270 300 330 360 500 750 1000
|
|
|
+
|
|
|
+ AIRFLOW - CFM
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 131
|
|
|
+OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+ACCESSORIES
|
|
|
+
|
|
|
+EK Series Electric Duct Heater
|
|
|
+
|
|
|
+AVA I L A B L E O N A L L C O M M E R C I A L U N I T S ( S O M E E X C E P T I O N S A P P LY )
|
|
|
+
|
|
|
+RenewAire offers the highest-efficiency energy recovery ventilators (ERVs) on the market. However, during
|
|
|
+winter conditions, supply air from the ERV may be less than optimal for space conditions. By adding
|
|
|
+C O N F I G U R A B L E E L E C T R I C D U C T H E AT E R S as an accessory to our
|
|
|
+commercial ERVs, RenewAire can now heat supply air during cooler months to enhance indoor comfort,
|
|
|
+all via one package for ERVs and heaters from a single source.
|
|
|
+
|
|
|
+ FLIPPABLE
|
|
|
+ EK SERIES
|
|
|
+ SHOWN
|
|
|
+
|
|
|
+KEY BENEFITS
|
|
|
+
|
|
|
+u A single source reduces time and costs: A single information u Ultimate reliability: RenewAire heaters come with our
|
|
|
+ source, a single purchase point and a single approval package two-year warranty and unmatched reliability. Single-source
|
|
|
+ for ERVs and heaters reduces design time and costs, and responsibility offers contractors and end users peace of
|
|
|
+ streamlines logistics for design engineers and contractors. mind and a single call location for technical, start-up and
|
|
|
+ commissioning questions.
|
|
|
+u More flexibility: RenewAire offers design engineers the
|
|
|
+ capacity to specify ERVs with a matching heater to boost u Highly certified: UL Listed (UL1996 Standard) and CSA certified.
|
|
|
+ flexibility and provide heated air to a single space or
|
|
|
+ multiple spaces.
|
|
|
+
|
|
|
+u Easy installation: A ZERO clearance rating to combustibles
|
|
|
+ allows designers and contractors to apply RenewAire heaters
|
|
|
+ with less restrictions onsite.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+132 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+EK SERIES Electric Duct Heater (1-175 kW)
|
|
|
+ Accessory
|
|
|
+ELECTRIC DUCT HEATER
|
|
|
+ SPECIFICATIONS
|
|
|
+Download specification at:
|
|
|
+renewaire.com/specifications Heater Type: Voltages & Phase:
|
|
|
+ Electric Duct Heater Single phase - 120, 208, 240, 277
|
|
|
+ Three phase - 208, 240, 480, 600
|
|
|
+ Typical KW Range:
|
|
|
+ 1–175 kW Control Voltage:
|
|
|
+ 24 VAC
|
|
|
+ Standard Features:
|
|
|
+ A disconnecting magnetic control contactor per Dimensions:
|
|
|
+ Minimum - 8" x 8" (W x H)
|
|
|
+ stage or each 48 Amp circuit within a stage Maximum - 99" x 99" (W x H)
|
|
|
+ Open-coil element
|
|
|
+ Staged on/off Options:
|
|
|
+ Control terminal board Flange mount
|
|
|
+ Grounding lugs 80-20 (Ni/Cr) A Grade element wire with
|
|
|
+ Automatic limit switch for primary over-
|
|
|
+ stainless steel terminals
|
|
|
+ temperature protection Recessed control box 1"
|
|
|
+ Manual reset limit switch for secondary over- Gasketed cover - dust tight
|
|
|
+ Power fusing, standard for heaters drawing more
|
|
|
+ temperature protection
|
|
|
+ Non-adjustable airflow switch than 48 Amps
|
|
|
+ Standard control transformer - 24 VAC 2-stage
|
|
|
+ Disconnect switch Electronic step controller (4-stage)
|
|
|
+ Duct thermostat with sensor for on/off control SCR (up to 96 Amps)
|
|
|
+ 60-20-20 (Ni/Cr/Fe) C Grade element wire with SCR Vernier (over 96 Amps)
|
|
|
+ Pilot light
|
|
|
+ nickel-plated terminals
|
|
|
+ Slip-in mount Accessory:
|
|
|
+ No left/right hand Room thermostat
|
|
|
+ Vertical up/down flow Room/duct thermostat-sensor kit for SCR control
|
|
|
+
|
|
|
+ Note: Electric duct heater designed for indoor ductwork installation only.
|
|
|
+
|
|
|
+ EK SEREIKESSeHrieEsAHTeaEteRr CCaApaPcAityCITY PRESSURPEREDSRSOUPRETHDRROOPUGTHHRHOEUAGTHERHEATER
|
|
|
+
|
|
|
+200 0.18
|
|
|
+
|
|
|
+175HEATER CAPACITY - kW 0.16 4
|
|
|
+
|
|
|
+150 Static Pressure Drop - Inches of Water 0.14
|
|
|
+
|
|
|
+ 3
|
|
|
+
|
|
|
+ 0.12
|
|
|
+
|
|
|
+125 0.1
|
|
|
+
|
|
|
+100 0.08 2
|
|
|
+
|
|
|
+ 0.06
|
|
|
+
|
|
|
+75
|
|
|
+
|
|
|
+ SAFE OPERATING 0.04
|
|
|
+
|
|
|
+50 RANGE 1
|
|
|
+
|
|
|
+ 0.02
|
|
|
+
|
|
|
+25 0
|
|
|
+ 0
|
|
|
+ 200
400
600
800
1000
1200
1400
1600
1800
2000
2200
|
|
|
+
|
|
|
+0 Air Velocity - FPM (1, 2, 3 and 4 - the number of rows of heater coils)
|
|
|
+ When the number of rows of heater coils is unknown, assume 4.
|
|
|
+ 0 2500 5000 7500 10000 12500
|
|
|
+
|
|
|
+ AIRFLOW - CFM
|
|
|
+
|
|
|
+ FLIPPABLE
|
|
|
+ CAPABILITIES
|
|
|
+
|
|
|
+ Unique to the EK series, this unit has the ability
|
|
|
+ to flip 180°. Additionally, EK heaters feature
|
|
|
+ both vertical up and vertical down airflow.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 133
|
|
|
+ T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
|
|
|
+
|
|
|
+134 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+ACCESSORIES
|
|
|
+
|
|
|
+Indirect Gas-Fired Duct Furnace
|
|
|
+
|
|
|
+AVA I L A B L E O N A L L C O M M E R C I A L U N I T S ( S O M E E X C E P T I O N S A P P LY )
|
|
|
+
|
|
|
+RenewAire offers some of the highest-efficiency energy recovery ventilators (ERVs) on the market. However,
|
|
|
+during winter conditions, supply air from the ERV may be less than optimal for space conditions. By providing
|
|
|
+an indoor and outdoor I N D I R E C T G A S - F I R E D D U C T F U R N A C E as an accessory
|
|
|
+for our commercial ERVs, in addition to the Electric Duct Heater, RenewAire ERVs now have increased
|
|
|
+flexibility for controlling supply-air temperature during cooler months. This enhances indoor comfort, makes
|
|
|
+ERV installations easier and is possible via a single source for ERVs and furnaces.
|
|
|
+
|
|
|
+ GH OUTDOOR SERIES
|
|
|
+ SHOWN
|
|
|
+
|
|
|
+KEY BENEFITS
|
|
|
+
|
|
|
+u A single source for your ERV and furnace reduces time and u Expert guidance: The RenewAire customer-support team will
|
|
|
+ costs: A single information source, a single purchase point and provide detailed and expert guidance for how best to install the
|
|
|
+ a single approval package for ERVs and heaters reduces design indoor and outdoor gas-fired duct furnace with an ERV.
|
|
|
+ time and costs, as well as streamlines logistics for design
|
|
|
+ engineers and contractors. u Ultimate reliability: RenewAire furnaces come with our
|
|
|
+ two-year warranty and unmatched reliability. Single-source
|
|
|
+u Increased capabilities and flexibility: RenewAire offers responsibility offers contractors and end users peace of
|
|
|
+ design engineers the capacity to specify ERVs with a matching mind and a single call location for technical, start-up and
|
|
|
+ indoor or outdoor gas-fired furnace to increase ERV capabilities commissioning questions.
|
|
|
+ and flexibility for providing a single space or multiple spaces
|
|
|
+ with tempered air conditions to equal wintertime loads. u Highly certified: ETL-listed to the requirements of ANSI Z83.8/
|
|
|
+ CSA 2.6.
|
|
|
+u More and easier applications: The addition of the indoor
|
|
|
+ and outdoor indirect gas-fired duct furnace as an option
|
|
|
+ ensures that RenewAire ERVs can be easily specified on more
|
|
|
+ applications that require gas heating of the recovered air.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 135
|
|
|
+OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+GH INDOOR Indirect Gas-Fired Duct Furnace
|
|
|
+ Accessory
|
|
|
+
|
|
|
+INDOOR SPECIFICATIONS Standard Features (continued):
|
|
|
+Indirect Gas-Fired Duct Furnace Flame rollout switch
|
|
|
+ Heater Type: Manual shut off valve
|
|
|
+ Indoor IN-KI shown Indirect Gas-Fired Duct Furnace 3/8" condensate drain connection
|
|
|
+Download specification at:
|
|
|
+renewaire.com/specifications Typical Input Capacity (MBH): Voltages & Phase:
|
|
|
+ 50, 75, 100, 125, 150, 175, Single phase - 120V, 208V, 230V
|
|
|
+ 200, 250, 300, 350, 400
|
|
|
+ Control Voltage:
|
|
|
+ Standard Features: 24 VAC
|
|
|
+ Tubular heaters
|
|
|
+ Indirect natural gas fired Dimensions:
|
|
|
+ Indoor installation See table 2
|
|
|
+ 80% thermal efficiency
|
|
|
+ Horizontal airflow Shipping:
|
|
|
+ Rated for elevations from 0 – 2,000 ft. Shipped loose with base unit and installed in the field
|
|
|
+ 409 stainless steel heat exchanger
|
|
|
+ 409 stainless steel burners Options:
|
|
|
+ Flue/combustion air – indoor models Indirect propane fired fuel
|
|
|
+ Elevation correction for elevation > 2,000 ft.
|
|
|
+ Vertical (separated indoor) 304 stainless steel heat exchanger
|
|
|
+ Vertical top exhaust with louvered intake 5:1 continuous electronic modulation for all furnaces
|
|
|
+ Direct spark ignition 10:1 continuous electronic modulation for furnaces
|
|
|
+ 1-stage/2-stage gas controls
|
|
|
+ Induced draft venting 200 MBH and larger
|
|
|
+ Terminal block for power and control wiring Duct thermostat for modulation control
|
|
|
+ Automatic high limit safety shut-off Disconnect switch
|
|
|
+ Auxiliary manual high limit switch Power fusing
|
|
|
+ Combustion air pressure switch
|
|
|
+ Air proving switch Accessory:
|
|
|
+ Combination gas valve with shutoff Duct thermostat for 1-stage/2-stage control
|
|
|
+ Duct thermostat for modulation control
|
|
|
+
|
|
|
+FLUE AND COMBUSTION AIR CONFIGURATION
|
|
|
+
|
|
|
+ IN-KI IN-SI Note: The total equivalent length of vent pipe must not exceed 50 feet. If equivalent length exceeds 50 feet refer
|
|
|
+ (TOP EXHAUST) (SEPARATE INLET EXHAUST) to IOM for recommendations.
|
|
|
+
|
|
|
+ FLUE FLUE COMBUSTION Caution: All indirect gas-fired duct furnaces to be installed downstream of the ERV and on the positive side of the
|
|
|
+EXHAUST EXHAUST INTAKE supply fan.
|
|
|
+
|
|
|
+AIRFLOW AIRFLOW AIRFLOW AIRFLOW
|
|
|
+
|
|
|
+ COMBUSTION
|
|
|
+ INTAKE
|
|
|
+
|
|
|
+TEMPERATURE RISE AND PRESSURE DROP
|
|
|
+
|
|
|
+ FIGURE 1 GAS FURNACE 50-200 MBH FIGURE 2 GAS FURNACE 250-400 MBH
|
|
|
+
|
|
|
+ Gas Furnace 50 ‐ 200 MBH Gas Furnace 250 ‐ 400 MBH
|
|
|
+
|
|
|
+60 0.32 60 1.6
|
|
|
+
|
|
|
+55 0.28 55 1.4
|
|
|
+
|
|
|
+50 200 50 1.2
|
|
|
+45
|
|
|
+40 0.24
|
|
|
+Temperature Rise (deg. F)35 400
|
|
|
+ Pressure Drop (inch‐w.c.)30
|
|
|
+ Temperature Rise (deg. F)252001750.2045 400 350
|
|
|
+ Pressure Drop (in.‐w.c.)20175
|
|
|
+ 150 0.16 350 1.0
|
|
|
+ 0
|
|
|
+ 40 300
|
|
|
+
|
|
|
+ 300 0.8
|
|
|
+
|
|
|
+ 125 0.12 35 250 250 0.6
|
|
|
+ 100
|
|
|
+ 75 150 0.08 30 0.4
|
|
|
+ 50 125
|
|
|
+ 100
|
|
|
+ 0.04 25 0.2
|
|
|
+ 50/75
|
|
|
+
|
|
|
+ 1000 2000 3000 4000 5000 6000 0.00 20 3000 4000 5000 6000 7000 8000 0.0
|
|
|
+ 7000 2000 Airflow (CFM) 9000 10000 11000 12000
|
|
|
+
|
|
|
+ Airflow (CFM)
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+136 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+ DUCT FURNACE DIMENSIONS FIGURE 4 IN-SI (SEPARATE INLET EXHAUST INDOOR)
|
|
|
+ FIGURE 3 IN-KI (TOP EXHAUST INDOOR)
|
|
|
+ 22.92 FLUE GAS EXHAUST 22.92
|
|
|
+ FLUE GAS EXHAUST (H) D (H)
|
|
|
+ D
|
|
|
+ 14.89 COMBUSTION AIR INLET 14.89
|
|
|
+ COMBUSTION AIR INLET D
|
|
|
+
|
|
|
+ 23.99 23.99
|
|
|
+ OUTDOOR TOP EXHAUST (NO)
|
|
|
+ OUTDOOR TOP EXHAUST (NO)
|
|
|
+ 47.85 47.85
|
|
|
+ (L) (L)
|
|
|
+
|
|
|
+ W UNLESS OTHERWISE SPECIFIED, RenewAire LLC 4510 Helgesen Dr. W UNLESS OTHERWISE SPECIFIED, RenewAire LLC 4510 Helgesen Dr.
|
|
|
+ DIMENSIONS ARE IN INCHES. Madison, WI 53718 USA DIMENSIONS ARE IN INCHES. Madison, WI 53718 USA
|
|
|
+ TABLE 2 TOLERANCES: TOLERANCES:
|
|
|
+ LINEAR 0.015 TEL: (608) 221-4499 TEL: (608) 221-4499
|
|
|
+ LEVEL DESCRIPTION OF REVISION HOLE SIZE 0.005 FAX: (608) 221-2824 FAX: (608) 221-2824
|
|
|
+ ANGULARITY 3 TOLL FREE: (800) 627-4499 TOLL FREE: (800) 627-4499
|
|
|
+ Size Tubes Input Rate SURFACE FINISH = LINEAR 0.015
|
|
|
+ HOLE SIZE 0.005
|
|
|
+ DESCRIPTION OF REVISION 63 MICROINCH MINIMUM TITLE: HDG-400-M-N GAS HEATER OUTDOOR ANGULARITY 3 TITLE: HDG-400-M-N GAS HEATER OUTDOOR
|
|
|
+ SURFACE FINISH =
|
|
|
+
|
|
|
+ 63 MICROINCH MINIMUM
|
|
|
+
|
|
|
+ MATERIAL: DRAWN BY: DATE: DWG. NO. - MATERIAL: DRAWN BY: DATE: DWG. NO.
|
|
|
+ INDOOR TOP EXHAUST (KI) - DO NOT SCALE DRAWING.
|
|
|
+ DO NOT SCALE DRAWING. CAH 10/19/16 SK4750A REMOVE ALL BURRS, BREAK CAH 10/19/16 SK4750A
|
|
|
+ REMOVE ALL BURRS, BREAK
|
|
|
+ SHARP EDGES. SHARP EDGES.
|
|
|
+ APPLICABLE STANDARDS: DIM.
|
|
|
+ AND TOL. ANSI Y14.5
|
|
|
+ APPLICABLE STANDARDS: DIM. Vent Locations INDOOR SEPARATED COMBUSTION (SI) DATE
|
|
|
+ AND TOL. ANSI Y14.5 FINISH:
|
|
|
+ ReneMwiAni/rMe aLLxCTemperature Rise through Furnace (°F) FINISH:CHECKED BY:DATE: SIZE A BY CHECKED BY: DATE: SIZE A SHEET 1 OF 1
|
|
|
+
|
|
|
+ BY
|
|
|
+ UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE IN INCHES.
|
|
|
+ TOLERANCES:
|
|
|
+ DATE -- -- SCALE:1:16 SHEET 1 OF 1 4510 Helgesen Dr. LEVEL DESCRIPTION OF REVISION -- -- SCALE:1:16
|
|
|
+ Madison, WI 53718 USA
|
|
|
+ Shipping 4510 Helgesen Dr.
|
|
|
+ TEL: (608) 221-4499 Madison, WI 53718 USA
|
|
|
+ FAX: (608) 221-2824 TEL: (608) 221-4499
|
|
|
+ TOLL FREE: (800) 627-4499 FAX: (608) 221-2824
|
|
|
+ LINEAR 0.015 UNLESS OTHERWISE SPECIFIED, Unit RenewAire LLC Weight TOLL FREE: (800) 627-4499
|
|
|
+ HOLE SIZE 0.005
|
|
|
+ TITLE: HDG100-M-KI IN-KI, IN-SI DIMENSIONS ARE IN INCHES. Diameter Weight TITLE: HDG100-M-KI
|
|
|
+ OutputANGULARITY 3 TOLERANCES:
|
|
|
+ SURFACE FINISH = LINEAR 0.015
|
|
|
+ 20 63 MICROINCH MINIMUM 25 30 DO NOT SCALE DRAWING. 35DATE: 40 DWG. NO. 45 50 55 60 HOLE SIZE 0.005
|
|
|
+ MATERIAL: ANGULARITY 3
|
|
|
+ DRAWN BY: SURFACE FINISH =
|
|
|
+
|
|
|
+ REMOVE ALL BURRS, BREAK SK4700A "W" "L" "H" 63 MICROINCH MINIMUM "D" DO NOT SCALE DRAWING.
|
|
|
+ SHARP EDGES.
|
|
|
+ APPLICABLE STANDARDS: DIM. CHECKED BY: DRAWN BY: DATE: DWG. NO.
|
|
|
+ FINISH: AND TOL. ANSI Y14.5 DATE: MATERIAL:
|
|
|
+ SK4700A
|
|
|
+LEVEL DATE BY SCALE:1:24 SIZE A SHEET 4 OF 4 REMOVE ALL BURRS, BREAK
|
|
|
+ SHARP EDGES.
|
|
|
+ APPLICABLE STANDARDS: DIM. CHECKED BY:
|
|
|
+ FINISH: AND TOL. ANSI Y14.5 DATE: SIZE A
|
|
|
+
|
|
|
+ MBH Qty. Btuh Btuh LEVEL DESCRIPTION OF REVISION DATE BY inch inch lb SCALE:1:24 SHEET 3 OF 4
|
|
|
+
|
|
|
+ Nom. Duct Opening Airflow (CFM) inch inch lb
|
|
|
+
|
|
|
+ 50 3 50,000 40,000 1852 1481 1235 1058 926 823 741 673 617 15.7 127 207
|
|
|
+
|
|
|
+ 75 3 75,000 60,000 2778 2222 1852 1587 1389 1235 1111 1010 926 15.7 127 207
|
|
|
+
|
|
|
+ 100 4 100,000 80,000 3704 2963 2469 2116 1852 1646 1481 1347 1235 18.4 5 142 222
|
|
|
+ 125 5 125,000 100,000 4630 3704 3086 2646 2315 2058 1852 1684 1543 21.2
|
|
|
+ 169 249
|
|
|
+
|
|
|
+ 150 6 150,000 120,000 5556 4444 3704 3175 2778 2469 2222 2020 1852 23.9 160 240
|
|
|
+
|
|
|
+ 175 7 175,000 140,000 6481 5185 4321 3704 3241 2881 2593 2357 2160 26.7 47.8 22.9 180 260
|
|
|
+
|
|
|
+ 200 8 200,000 160,000 7407 5926 4938 4233 3704 3292 2963 2694 2469 29.4 196 276
|
|
|
+
|
|
|
+ 250 10 250,000 200,000 9259 7407 6173 5291 4630 4115 3704 3367 3086 34.9 245 325
|
|
|
+
|
|
|
+ 300 12 300,000 240,000 11111 8889 7407 6349 5556 4938 4444 4040 3704 40.4 6 279 384
|
|
|
+
|
|
|
+ 350 14 350,000 280,000 12963 10370 8642 7407 6481 5761 5185 4714 4321 45.9 324 429
|
|
|
+
|
|
|
+ 400 15 400,000 320,000 14815 11852 9877 8466 7407 6584 5926 5387 4938 48.7 394 499
|
|
|
+
|
|
|
+ Note: For a single furnace, 20° F minimum temperature rise, 60° F maximum temperature rise.
|
|
|
+ INDIRECT GAS-FIRED DUCT FURNACE DIMENSIONS
|
|
|
+
|
|
|
+ NOTES
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS SUBJECT TO
|
|
|
+ CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ TOP VIEW
|
|
|
+
|
|
|
+ 36"
|
|
|
+ Service Area
|
|
|
+
|
|
|
+ 14 7/8" 47 3/8"
|
|
|
+ Opening Case
|
|
|
+
|
|
|
+ 6 1/8" View Port 25" 14 7/8"
|
|
|
+ Case Opening
|
|
|
+
|
|
|
+ 6 1/8"
|
|
|
+
|
|
|
+ 24" 24"
|
|
|
+
|
|
|
+ 3" Opening 3/8" Condensate Opening 3"
|
|
|
+ LEFT VIEW
|
|
|
+ Power Wiring and Drain Tube
|
|
|
+
|
|
|
+ Control Wiring 3/4" Gas Connection RIGHT VIEW
|
|
|
+ Inlet Fittings FRONT VIEW
|
|
|
+
|
|
|
+ UNLESS OTHERWISE SPECIFIED, RenewAire LLC Specifications may be subject to change without 4510 Helgesen Dr. notice.
|
|
|
+ DIMENSIONS ARE IN INCHES. Madison, WI 53718 USA
|
|
|
+ TOLERANCES: TEL: (608) 221-4499
|
|
|
+ LINEAR 0.015 FAX: (608) 221-2824
|
|
|
+ HOLE SIZE 0.005 TOLL FREE: (800) 627-4499
|
|
|
+ ANGULARITY 3
|
|
|
+ SURFACE FINISH = HDG100-M-KI DIM SPEC FOTIRTLET:HE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 137
|
|
|
+
|
|
|
+ 63 MICROINCH MINIMUM
|
|
|
+
|
|
|
+ DRAWN BY: DATE: DWG. NO.
|
|
|
+OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+GH OUTDOOR Indirect Gas-Fired Duct Furnace
|
|
|
+ Accessory
|
|
|
+
|
|
|
+ROOFTOP SPECIFICATIONS Standard Features (continued):
|
|
|
+Indirect Gas-Fired Duct Furnace Combination gas valve with shutoff
|
|
|
+ Heater Type: Flame rollout switch
|
|
|
+ Rooftop RT-NO shown Indirect Gas-Fired Duct Furnace Manual shut off valve
|
|
|
+Download specification at: 3/8" condensate drain connection
|
|
|
+renewaire.com/specifications Typical Input Capacity (MBH):
|
|
|
+ 50, 75, 100, 125, 150, 175, Voltages & Phase:
|
|
|
+ 200, 250, 300, 350, 400 Single phase - 120V, 208V, 230V
|
|
|
+
|
|
|
+ Standard Features: Control Voltage:
|
|
|
+ Tubular heaters 24 VAC
|
|
|
+ Indirect natural gas fired
|
|
|
+ Outdoor installation Dimensions:
|
|
|
+ 80% thermal efficiency See table 1
|
|
|
+ Horizontal airflow
|
|
|
+ Rated for elevations from 0 – 2,000 ft. Shipping:
|
|
|
+ 409 stainless steel heat exchanger Shipped loose with base unit and installed in the field
|
|
|
+ 409 stainless steel burners
|
|
|
+ Flue/combustion air – outdoor models Options:
|
|
|
+ Indirect propane fired fuel
|
|
|
+ Horizontal separated outdoor with hoods Elevation correction for elevation > 2,000 ft.
|
|
|
+ Vertical top exhaust with intake hood 304 stainless steel heat exchanger
|
|
|
+ Direct spark ignition 5:1 continuous electronic modulation for all furnaces
|
|
|
+ 2-stage gas controls 10:1 continuous electronic modulation for furnaces
|
|
|
+ Induced draft venting
|
|
|
+ Terminal block for power and control wiring 200 MBH and larger
|
|
|
+ Automatic high limit safety shut-off Duct thermostat for modulation control
|
|
|
+ Auxiliary manual high limit switch Disconnect switch
|
|
|
+ Combustion air pressure switch Power fusing
|
|
|
+ Air proving switch
|
|
|
+ Accessory:
|
|
|
+ Duct thermostat for 2-stage control
|
|
|
+ Duct thermostat for modulation control
|
|
|
+ Duct curb
|
|
|
+
|
|
|
+FLUE AND COMBUSTION AIR CONFIGURATION
|
|
|
+
|
|
|
+ RT-NO RT-WO Caution: All indirect gas-fired duct furnaces to be installed downstream of the ERV and on the positive side of the
|
|
|
+ (TOP EXHAUST) (FRONT EXHAUST) supply fan.
|
|
|
+
|
|
|
+ FLUE
|
|
|
+ EXHAUST
|
|
|
+
|
|
|
+ AIRFLOW AIRFLOW FLUE AIRFLOW
|
|
|
+ EXHAUST
|
|
|
+
|
|
|
+ AIRFLOW
|
|
|
+
|
|
|
+ COMBUSTION COMBUSTION
|
|
|
+ INTAKE INTAKE
|
|
|
+
|
|
|
+TEMPERATURE RISE AND PRESSURE DROP
|
|
|
+
|
|
|
+ FIGURE 1 GAS FURNACE 50-200 MBH FIGURE 2 GAS FURNACE 250-400 MBH
|
|
|
+
|
|
|
+ Gas Furnace 50 ‐ 200 MBH Gas Furnace 250 ‐ 400 MBH
|
|
|
+
|
|
|
+60 0.32 60 1.6
|
|
|
+
|
|
|
+55 0.28 55 1.4
|
|
|
+
|
|
|
+50 200 50 1.2
|
|
|
+
|
|
|
+ 0.24
|
|
|
+Temperature Rise (deg. F) 400
|
|
|
+ Pressure Drop (inch‐w.c.)
|
|
|
+45 Temperature Rise (deg. F)2001750.2045 400 350
|
|
|
+ Pressure Drop (in.‐w.c.)
|
|
|
+ 175 1.0
|
|
|
+
|
|
|
+40 150 0.16 350 300
|
|
|
+
|
|
|
+ 40 0.8
|
|
|
+
|
|
|
+ 300
|
|
|
+
|
|
|
+35 125 0.12 35 250 250 0.6
|
|
|
+
|
|
|
+ 100
|
|
|
+
|
|
|
+30 75 150 0.08 30 0.4
|
|
|
+
|
|
|
+ 50 125 0.04 25 0.2
|
|
|
+ 100
|
|
|
+25
|
|
|
+ 50/75
|
|
|
+
|
|
|
+20 0.00 20 0.0
|
|
|
+ 7000 2000 9000 10000 11000 12000
|
|
|
+ 0 1000 2000 3000 4000 5000 6000 3000 4000 5000 6000 7000 8000
|
|
|
+ Airflow (CFM)
|
|
|
+ Airflow (CFM)
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+138 RENEWAIRE.COM 1.800.627.4499
|
|
|
+DUCT FURNACE DIMENSIONS OPTIONS & ACCESSORIES
|
|
|
+FIGURE 3 RT-NO (TOP EXHAUST OUTDOOR)
|
|
|
+ FIGURE 4 RT-WO (FRONT EXHAUST OUTDOOR)
|
|
|
+
|
|
|
+ FLUE GAS EXHAUST 22.92 FLUE GAS EXHAUST 34.92
|
|
|
+ D (H) COMBUSTION AIR INLET (H)
|
|
|
+
|
|
|
+COMBUSTION AIR INLET 14.89 14.89
|
|
|
+
|
|
|
+ 23.99
|
|
|
+
|
|
|
+ 47.85 23.99
|
|
|
+
|
|
|
+ W (L)
|
|
|
+
|
|
|
+ W 47.85
|
|
|
+
|
|
|
+ (L)
|
|
|
+
|
|
|
+ TABLE 1 OUTDOOR TOP EXHAUST (NO)
|
|
|
+
|
|
|
+ Size Tubes UNLESS OTHERWISE SPECIFIED, 4510 Helgesen Dr. OUTDOOR FRONT EXHAUST (WO)
|
|
|
+ Madison, WI 53718 USA
|
|
|
+LEVEL DESCRIPTION OF REVISION TEL: (608) 221-4499
|
|
|
+ FAX: (608) 221-2824
|
|
|
+
|
|
|
+ TOLL FREE: (800) 627-4499
|
|
|
+ DIMENSIONS ARE IN INCHES. RenewAire LLC
|
|
|
+ TOLERANCES:
|
|
|
+ LINEAR 0.015 MHiDnG/M-4ax00T-eMm-pNerGatAuSreHREiAseTEtRhrOouUgThDFOuOrnRace (°F) TITLE: Vent Locations UNLESS OTHERWISE SPECIFIED,
|
|
|
+ HOLE SIZE 0.005 DIMENSIONS ARE IN INCHES. 4510 Helgesen Dr.
|
|
|
+ ANGULARITY 3 RenewAire LLC TOLERANCES: Madison, WI 53718 USA
|
|
|
+ SURFACE FINISH = LINEAR 0.015
|
|
|
+ Output63 MICROINCH MINIMUM Unit Shipping HOLE SIZE 0.005 TEL: (608) 221-4499
|
|
|
+ Input Rate FAX: (608) 221-2824
|
|
|
+ RT-NO, RT-WO RT-NO RT-WO Diameter ANGULARITY 3 TOLL FREE: (800) 627-4499
|
|
|
+ SURFACE FINISH =
|
|
|
+ - MATERIAL: DRAWN BY: DATE: DWG. NO. FRONT EXHAUWSTeiOghUtTDOWOeRig(hWt O) 63 MICROINCH MINIMUMTITLE:
|
|
|
+ 25 30 35 DO NOT SCALE DRAWING.
|
|
|
+ CAH 40SK475405A 50
|
|
|
+ REMOVE ALL BURRS, BREAK
|
|
|
+ SHARP EDGES.
|
|
|
+ APPLICABLE STANDARDS: DIM.
|
|
|
+ AND TOL. ANSI Y14.5
|
|
|
+ 20 10/19/16 55 60
|
|
|
+
|
|
|
+ FINISH: CHECKED BY: DATE: "W" "L" "H" MATERIAL: "H" "D" DO NOT SCALE DRAWING. DRAWN BY: DATE: DWG. NO.
|
|
|
+ REMOVE ALL BURRS, BREAK DATE:
|
|
|
+ DATE BY -- -- SCALE:1:16 SIZE A SHEET 1 OF 1 HDG-400-M-W
|
|
|
+
|
|
|
+ SHARP EDGES.
|
|
|
+ APPLICABLE STANDARDS: DIM. CHECKED BY:
|
|
|
+ FINISH: AND TOL. ANSI Y14.5 SIZE A SHEET 1 OF 1
|
|
|
+ LEVEL DESCRIPTION OF REVISION DATE SCALE:1:16
|
|
|
+ BY
|
|
|
+ Nom. Duct Opening Airflow (CFM)
|
|
|
+MBH Qty. Btuh Btuh inch inch inch inch inch lb lb
|
|
|
+
|
|
|
+50 3 50,000 40,000 1852 1481 1235 1058 926 823 741 673 617 15.7 127 207
|
|
|
+
|
|
|
+75 3 75,000 60,000 2778 2222 1852 1587 1389 1235 1111 1010 926 15.7 127 207
|
|
|
+
|
|
|
+100 4 100,000 80,000 3704 2963 2469 2116 1852 1646 1481 1347 1235 18.4 142 222
|
|
|
+ 5
|
|
|
+ 169 249
|
|
|
+125 5 125,000 100,000 4630 3704 3086 2646 2315 2058 1852 1684 1543 21.2
|
|
|
+
|
|
|
+150 6 150,000 120,000 5556 4444 3704 3175 2778 2469 2222 2020 1852 23.9 160 240
|
|
|
+
|
|
|
+175 7 175,000 140,000 6481 5185 4321 3704 3241 2881 2593 2357 2160 26.7 47.8 22.9 34.9 180 260
|
|
|
+
|
|
|
+200 8 200,000 160,000 7407 5926 4938 4233 3704 3292 2963 2694 2469 29.4 196 276
|
|
|
+
|
|
|
+250 10 250,000 200,000 9259 7407 6173 5291 4630 4115 3704 3367 3086 34.9 245 325
|
|
|
+
|
|
|
+300 12 300,000 240,000 11111 8889 7407 6349 5556 4938 4444 4040 3704 40.4 6 279 384
|
|
|
+
|
|
|
+350 14 350,000 280,000 12963 10370 8642 7407 6481 5761 5185 4714 4321 45.9 324 429
|
|
|
+
|
|
|
+400 15 400,000 320,000 14815 11852 9877 8466 7407 6584 5926 5387 4938 48.7 394 499
|
|
|
+
|
|
|
+Note: For a single furnace, 20° F minimum temperature rise, 60° F maximum temperature rise.
|
|
|
+
|
|
|
+INDIRECT GAS-FIRED DUCT FURNACE DIMENSIONS
|
|
|
+
|
|
|
+ NOTES
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS SUBJECT TO
|
|
|
+ CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 36"
|
|
|
+ Service Area
|
|
|
+
|
|
|
+ TOP VIEW 47 7/8"
|
|
|
+ Case
|
|
|
+
|
|
|
+ 14 7/8" Case 14 7/8"
|
|
|
+Opening Opening
|
|
|
+ 37" (WO) Shown
|
|
|
+6 1/8" 6 1/8"
|
|
|
+ View Port 25" (NO)
|
|
|
+
|
|
|
+ 24" 3/8" Condensate 24"
|
|
|
+ Opening Power Wiring and Drain Tube Opening
|
|
|
+
|
|
|
+ 3" Control Wiring 3/4" Gas Connection 3"
|
|
|
+ LEFT VIEW Inlet Fittings FRONT VIEW
|
|
|
+ RIGHT VIEW
|
|
|
+
|
|
|
+ UNLESS OTHERWISE SPECIFIED, RenewAire LLC Specifications may be subject to change without 4510 Helgesen Dr. notice.
|
|
|
+ DIMENSIONS ARE IN INCHES. Madison, WI 53718 USA
|
|
|
+ TOLERANCES: TEL: (608) 221-4499
|
|
|
+ LINEAR 0.015 FAX: (608) 221-2824
|
|
|
+ HOLE SIZE 0.005 TOLL FREE: (800) 627-4499
|
|
|
+ ANGULARITY 3
|
|
|
+ SURFACE FINISH = FOTIRTLET:HE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 139
|
|
|
+
|
|
|
+ 63 MICROINCH MINIMUM FRONT EXHAUST OUTDOOR (WO)DIM SPEC
|
|
|
+
|
|
|
+ DRAWN BY: DATE: DWG. NO.
|
|
|
+CERTIFICATIONS & PERFORMANCE
|
|
|
+
|
|
|
+AHRI 1060
|
|
|
+
|
|
|
+CERTIFIED PERFORMANCE
|
|
|
+
|
|
|
+Energy recovery component certified in accordance with AHRI Standard 1060-2013.
|
|
|
+Actual performance in packaged equipment may vary.
|
|
|
+
|
|
|
+ AHRI-1060 Certified Performance - Model Number L125-G5
|
|
|
+
|
|
|
+ Type Tilt Angle Nominal Airflow Pressure Drop
|
|
|
+ Plate N/A
|
|
|
+ 100% - 750 SCFM 0.65 in. H20
|
|
|
+ Leakage Ratings 75% - 563 SCFM
|
|
|
+
|
|
|
+ Thermal Effectiveness Ratings at 0" Pressure Differential
|
|
|
+
|
|
|
+ Pressure EATR OACF Purge Angle or Nominal Airflow Sensible Latent Total Net Net Net Net
|
|
|
+Differential Setting Airflow Sensible Latent Total
|
|
|
+-1 in. H20
|
|
|
+ 1.0% 1.00 N/A 750 Heating 70% 52% 64% 750 70% 52% 64%
|
|
|
+ 0 in. H20
|
|
|
+ CFM Cooling 70% 42% 53% CFM 70% 42% 53%
|
|
|
+ 1 in. H20
|
|
|
+ 0.0% 1.02 N/A
|
|
|
+
|
|
|
+ 563 Heating 74% 59% 69% 563 74% 59% 69%
|
|
|
+
|
|
|
+ 0.0% 1.05 N/A CFM Cooling 74% 49% 58% CFM 74% 49% 58%
|
|
|
+
|
|
|
+ AHRI-1060 Certified Performance - Model Number L85-G5
|
|
|
+
|
|
|
+ Type Tilt Angle Nominal Airflow Pressure Drop
|
|
|
+
|
|
|
+ Plate N/A 100% - 500 SCFM 0.65 in. H20
|
|
|
+ Leakage Ratings 75% - 375 SCFM
|
|
|
+
|
|
|
+ Thermal Effectiveness Ratings at 0" Pressure Differential
|
|
|
+
|
|
|
+ Pressure EATR OACF Purge Angle or Nominal Airflow Sensible Latent Total Net Net Net Net
|
|
|
+Differential Setting Airflow Sensible Latent Total
|
|
|
+-1 in. H20
|
|
|
+ 1.0% 1.00 N/A 500 Heating 70% 52% 64% 500 70% 52% 64%
|
|
|
+ 0 in. H20
|
|
|
+ CFM Cooling 70% 42% 53% CFM 70% 42% 53%
|
|
|
+ 1 in. H20
|
|
|
+ 0.0% 1.02 N/A
|
|
|
+
|
|
|
+ 375 Heating 74% 59% 69% 375 74% 59% 69%
|
|
|
+
|
|
|
+ 0.0% 1.05 N/A CFM Cooling 74% 49% 58% CFM 74% 49% 58%
|
|
|
+
|
|
|
+ AHRI-1060 Certified Performance - Model Number L62-G5
|
|
|
+
|
|
|
+ Type Tilt Angle Nominal Airflow Pressure Drop
|
|
|
+
|
|
|
+ Plate N/A 100% - 350 SCFM 0.65 in. H20
|
|
|
+ Leakage Ratings 75% - 263 SCFM
|
|
|
+
|
|
|
+ Thermal Effectiveness Ratings at 0" Pressure Differential
|
|
|
+
|
|
|
+ Pressure EATR OACF Purge Angle or Nominal Airflow Sensible Latent Total Net Net Net Net
|
|
|
+Differential Setting Airflow Sensible Latent Total
|
|
|
+-1 in. H20
|
|
|
+ 1.0% 1.00 N/A 350 Heating 70% 52% 64% 350 70% 52% 64%
|
|
|
+ 0 in. H20
|
|
|
+ CFM Cooling 70% 42% 53% CFM 70% 42% 53%
|
|
|
+ 1 in. H20
|
|
|
+ 0.0% 1.02 N/A
|
|
|
+
|
|
|
+ 263 Heating 74% 59% 69% 263 74% 59% 69%
|
|
|
+
|
|
|
+ 0.0% 1.05 N/A CFM Cooling 74% 49% 58% CFM 74% 49% 58%
|
|
|
+
|
|
|
+NOTE: SCFM = Standard Cubic Feet per Minute OACF = Outdoor Air Correction Factor EATR = Exhaust Air Transfer Ratio N/A = Not Applicable
|
|
|
+
|
|
|
+140 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ ORDERING & SUPPORT
|
|
|
+
|
|
|
+ EV450/HE MODEL
|
|
|
+ CONFIGURATION GUIDE
|
|
|
+
|
|
|
+ Note: Not all options are available on every model.
|
|
|
+
|
|
|
+MODEL NUMBER J - -- -
|
|
|
+
|
|
|
+DIGIT NUMBER 123 4 567 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
|
|
|
+
|
|
|
+Digits 1 - 5: Model Digit 18: Flow Control* (see Restrictions 11, 12, & 14)
|
|
|
+"EV450", "HE-1X", "HE1.5","HE-2X",
|
|
|
+"HE-3X", "HE-4X", "HE-6X, "HE-8X" "-" = No Isolation Dampers (with no Bypass)
|
|
|
+ "D" = Motorized Damper both Airstreams (with no Bypass)
|
|
|
+ Digits 7 - 8: Location "E" = Motorized Damper EA or RA Airstream (with no Bypass)
|
|
|
+"IN" = Indoor "F" = Motorized Damper FA or OA Airstream (with no Bypass)
|
|
|
+"RT" = Rooftop "S" = Backdraft Damper OA Airstream (with no Bypass)
|
|
|
+ "R" = Backdraft Damper EA Airstream (with no Bypass)
|
|
|
+Digit 9: Orientation (see Restriction 1) "B" = Backdraft Damper both Airstreams (with no Bypass)
|
|
|
+ "T" = Motorized Damper OA, Backdraft Damper EA (with no Bypass)
|
|
|
+"V", "H" (Indoor Units) "0" = Dry Bulb Bypass Dampers only
|
|
|
+"V", "H", "R", "F", "C" (Rooftop Units) "1" = Dry Bulb Bypass with Motorized Dampers all Airstreams
|
|
|
+"-" = Default in EV450 "4" = Dry Bulb Bypass with Backdraft Damper OA Airstream
|
|
|
+ "5" = Enthalpy Bypass Dampers only
|
|
|
+ Digit 11: Wall Type "6" = Enthalpy Bypass with Motorized Dampers all Airstreams
|
|
|
+"S" = Single "9" = Enthalpy Bypass with Backdraft Damper OA Airstream
|
|
|
+"D" = Double
|
|
|
+ Digit 19: Unit Control (see Restrictions 8, 9, 10, 15, & 16)
|
|
|
+
|
|
|
+Digit 12: Phase (see Restriction 7) "A" = Standard Unit Control Wiring
|
|
|
+ "D" = Independent Blower Control (HE-1X and HE1.5 only)
|
|
|
+"1" = Single Phase "V" = Onboard VFD Both Airstreams
|
|
|
+"3" = Three Phase "F" = Onboard VFD FA Airstream
|
|
|
+ "E" = Onboard VFD EA Airstream
|
|
|
+Digit 13: Voltage (see Restrictions 2, 3, 4, 5, 6 & 18)) "G" = Terminal Strip for EC Motors or Impellers
|
|
|
+
|
|
|
+"1" = 115V Digit 20: Unit Fusing
|
|
|
+"4" = 460V
|
|
|
+"5" = 208-230V "N" = Non-Fused (Standard)
|
|
|
+"8" = 575V "F" = Fused
|
|
|
+"9" = 277V
|
|
|
+
|
|
|
+Digit 14: FA Horsepower (see Restriction 7 & 18) Digit 21: Unit Control Enhancements (see Restrictions 16 & 17)
|
|
|
+
|
|
|
+"-" = Standard EV450 Motors "T" = Transformer with Isolation Relay (Standard)
|
|
|
+"H" = 0.75 HP Standard Direct-Drive Motors (HE-1X only) "1" = Enhanced Controls
|
|
|
+"E" = EC Direct Drive Motors (EV450, HE-1X and HE1.5 only) "2" = Premium Controls
|
|
|
+"S" = Standard Impellers (HE1.5 only) "3" = Enhanced Controls with BACNET License
|
|
|
+"U" = 1.5HP (HE-2X only) "4" = Premium Controls with BACNET License
|
|
|
+"V" = 2HP (HE-2X, HE-3X, HE-4X only)
|
|
|
+"W" = 3HP (HE-3X, HE-4X only) Digit 22: Filter Options (see Restriction 17)
|
|
|
+"X" = 5HP (HE-3X, HE-4X, HE-6X, HE-8X only)
|
|
|
+"Y" = 7.5HP (HE-6X, HE-8X only) "-" = None
|
|
|
+"Z" = 10HP (HE-8X only) "F" = Filter Monitor Both Airstreams
|
|
|
+
|
|
|
+ Digit 23: Other Options
|
|
|
+
|
|
|
+Digit 15: EA Horsepower (see Restriction 7 & 18) "-" = None (Reserved)
|
|
|
+
|
|
|
+"-" = Standard EV450 Motors Digit 24: Paint and Customization
|
|
|
+"H" = 0.75 HP Standard Direct-Drive Motors (HE-1X only)
|
|
|
+"E" = EC Direct Drive Motors (EV450, HE-1X and HE1.5 only) "-" = None
|
|
|
+"S" = Standard Impellers (HE1.5 only) "W" = White Paint
|
|
|
+"U" = 1.5HP (HE-2X only) "C" = Custom Paint
|
|
|
+"V" = 2HP (HE-2X, HE-3X, HE-4X only) "X" = Custom Unit
|
|
|
+"W" = 3HP (HE-3X, HE-4X only)
|
|
|
+"X" = 5HP (HE-3X, HE-4X, HE-6X, HE-8X only) Digit 25: Safety Listing (see Restriction 13)
|
|
|
+"Y" = 7.5HP (HE-6X, HE-8X only)
|
|
|
+"Z" = 10HP (HE-8X only) "L" = Listed
|
|
|
+ "N" = Non-Listed
|
|
|
+
|
|
|
+*NOTES:
|
|
|
+Digit 6 "J" = G5 Core Type Digits 10, 16 and 17 are not used in these models. Digit 15 is not used in EV450 models.
|
|
|
+*Digit 18: Flow Control: Codes for Bypass: Face damper also acts as Isolation damper in EA or RA Airstream.
|
|
|
+
|
|
|
+Restrictions:
|
|
|
+ 1: Orientation Code "C" not available with models EV450, HE-6X, HE-8X, HE1.5
|
|
|
+ 2: Voltage Codes "1" & "9" only available with Phase Code "1" (Single-Phase).
|
|
|
+ 3: Voltage Codes "4" & "8" only available with Phase Code "3" (Three-Phase).
|
|
|
+ 4: Voltage Code "9" (277V) only available with EV450, HE-1X & HE1.5 models.
|
|
|
+ 5: Voltage Code "8" (575V) not available with EV450, HE-1X & HE1.5 models.
|
|
|
+ 6: Voltage Code "1" only available with FA/EA Horsepower Codes "EE", "E-", "H", "S","U", "V" & "-".
|
|
|
+ 7: Motor Codes "E-" & "EE" (EC Motors) only available with Phase Code "1" (Single Phase)
|
|
|
+ 8: Unit Control Codes " V, F & E" not available in EV450, HE-1XIN, HE1.5IN & HE-1XRTC.
|
|
|
+ 9: Unit Control Code "G" (Terminal Strip) only available in EV450, HE-1X & HE1.5 with Motor Codes "E-" and "EE" (EC Motors).
|
|
|
+ 10: Unit Control Code "D" only available in HE-1X & HE1.5.
|
|
|
+ 11: Dampers and Bypass not available in EV450 or with Orientation Code "C".
|
|
|
+ 12: Backdraft Dampers only available with HE1.5 models.
|
|
|
+ 13: Some units with Customization Code "X", HE-6X & HE-8X models are not safety listed.
|
|
|
+ 14: Bypass only available with Location Code "IN".
|
|
|
+ 15: Unit Control Codes "V", "E" & "F" not available with Voltage Code "1".
|
|
|
+ 16: Unit Control "A" not available with Unit Control Enhancements Codes "1", "2", "3" & "4" in HE-1X and HE-1.5 models.
|
|
|
+ 17: Filter Code "F" not available with Unit Control Enhancements Codes "1", "2", "3" & "4". Filter Monitor is provided with those options.
|
|
|
+ 18: Voltage Code "9" not available with FA/EA Horsepower Codes "EE" & "E-".
|
|
|
+
|
|
|
+ ForToTePclhanciecCaalnOSMOurpMdpeEorRrEtC-EmIE-AmVaLial&:PilR:RHReOEneDenMweUwOaCiaDrTeiErOeCLSrOSdueDprEpso@CrtrH@eAnreeRwnTeawiraei.rceo.mcom
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 141
|
|
|
+ORDERING & SUPPORT
|
|
|
+
|
|
|
+ EK SERIES ELECTRIC DUCT HEATER
|
|
|
+ CONFIGURATION GUIDE
|
|
|
+
|
|
|
+ Note: Not all options are available on every model.
|
|
|
+
|
|
|
+MODEL NUMBER -
|
|
|
+
|
|
|
+DIGIT NUMBER 123 4 567 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
|
|
|
+
|
|
|
+Digits 1 - 2: Heater Type Digit 18: Voltage (see Restrictions 7 & 8)
|
|
|
+"EK "= Electric Heater (Standard) "1" = 120V
|
|
|
+ "2" = 208V
|
|
|
+ Digits 4 - 5: Width in Inches (see Restriction 1) "3" = 240V
|
|
|
+08-99 "4" = 480V
|
|
|
+ "8" = 600V
|
|
|
+ "9" = 277V
|
|
|
+
|
|
|
+ Digits 6 - 7: Height in Inches (see Restriction 2) Digit 19: Phase
|
|
|
+08-99
|
|
|
+ "1" = Single-Phase
|
|
|
+ Digits 8 - 10: Capacity in kW (see Restrictions 3, 4 & 5) "3" = Three-Phase
|
|
|
+001-175
|
|
|
+ Digit 20: Power Fusing (see Restriction 9)
|
|
|
+ "-" = None
|
|
|
+Digit 11: Mount "F" = Fusing
|
|
|
+
|
|
|
+"S" = Slip In (Standard) Digit 21: Stage
|
|
|
+"F = Flanged
|
|
|
+
|
|
|
+Digit 12: Element Style "1" = Single (Standard)
|
|
|
+ "2" = 2-Stage
|
|
|
+"C" = Open Coil (Standard) "4" = 4-Stage
|
|
|
+
|
|
|
+Digit 13: Element Material Digit 22: Control Voltage
|
|
|
+
|
|
|
+"C" = 60-20-20 Ni-Cr-Fe with Nickel Plate Terminal Pins (Standard) "S" = 24VAC
|
|
|
+"A" = 80-20 Ni-Cr with Stainless Steel Terminal Pins
|
|
|
+
|
|
|
+Digit 14: Airflow Orientation Digit 23: Control Type (see Restrictions 10, 11 & 12)
|
|
|
+
|
|
|
+"H" = Horizontal (Standard) "D" = Duct Thermostat with Sensor (Standard)
|
|
|
+"V" = Vertical "E" = Electronic Step Control with Sensor
|
|
|
+ "S" = SCR (For BAS System)
|
|
|
+Digit 15: Control Box Offset "V" = SCR with Analog Sensor (0-10Vdc)
|
|
|
+
|
|
|
+"L" = Left Hand (Standard) Digit 24: Time Delay
|
|
|
+"R" = Right Hand
|
|
|
+
|
|
|
+ "-" = None (Standard)
|
|
|
+
|
|
|
+Digit 16: Control Box Recessed
|
|
|
+
|
|
|
+"-" = None (Standard) Digit 25: Pilot Light
|
|
|
+"R" = Recessed 1"
|
|
|
+ "N" = None (Standard)
|
|
|
+Digit 17: Control Box Dust Tight "L" = Light
|
|
|
+
|
|
|
+"-" = None (Standard)
|
|
|
+"D" = Dust Tight
|
|
|
+
|
|
|
+*NOTES:
|
|
|
+Digit 3 is not used in this model.
|
|
|
+All heaters come with standard features: Disconnect Switch, Air Flow Switch (non adjustable), Control Transformer
|
|
|
+Descriptions of feature and options are found in the installation and operation manual.
|
|
|
+
|
|
|
+Restrictions:
|
|
|
+
|
|
|
+1: Width inches entered as a whole number.
|
|
|
+2: Height inches entered as a whole number.
|
|
|
+3: Heater density should be less than 30kW/ft². DENSITY= HEATER CAPACITY (kW) < 30
|
|
|
+ (W" x H")/144
|
|
|
+4: Heater capacity kW entered as a whole number.
|
|
|
+5: Formulas for calculating kW and temperature rise: kW = CFM x ΔT ΔT = kW x 3150
|
|
|
+ 3150 CFM
|
|
|
+7: Voltage Codes "1" & "9" only available with Phase Code "1" (Single-Phase).
|
|
|
+8: Voltage Codes "4" & "8" only available with Phase Code "3" (Three-Phase).
|
|
|
+9: Power Fusing Code "F" required when amperage is >48A. (based on kW and voltage)
|
|
|
+10: Control Type Code "D" only available with Stage Code "1" & "2".
|
|
|
+11: Control Type Code "E" only available with Stage Code "4".
|
|
|
+12: Control Type Code "S" & "V" only available with Stage Code "1", unless amperage is greater than or equal to 96A, then Stage Code "4" is automatically selected.
|
|
|
+
|
|
|
+ For TechnicEalLSEupCpoTrtREI-CmaPil:OReSnTewHairEeSAuTpport@renewaire.com
|
|
|
+ ToCPOlacNeFanIGOUrdeRr AE-TmIaOil:NReCneOwaDireEOrCdeHrsA@RreTnewaire.com
|
|
|
+
|
|
|
+142 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ ORDERING & SUPPORT
|
|
|
+
|
|
|
+GH SERIES INDIRECT GAS-FIRED DUCT
|
|
|
+ FURNACE CONFIGURATION GUIDE
|
|
|
+
|
|
|
+ Note: Not all options are available on every model.
|
|
|
+
|
|
|
+MODEL NUMBER - - --
|
|
|
+
|
|
|
+DIGIT NUMBER 123 4 567 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
|
|
|
+
|
|
|
+Digits 1 - 2: Duct Furnace Type Digit 17: Disconnect Switch
|
|
|
+"GH" = Gas Furnace 50-400 MBH
|
|
|
+ "N" = None (Standard)
|
|
|
+ "D" = Disconnect Switch
|
|
|
+
|
|
|
+ Digits 4 - 5: Location Digit 18: System/Inducer Voltage (see Restriction 2)
|
|
|
+"IN" = Indoor "1" = 115V
|
|
|
+"RT" = Rooftop "2" = 208V
|
|
|
+ "3" = 230V
|
|
|
+ Digits 6 - 7: Vent Location
|
|
|
+"SI" = Separated Top Indoor Digit 19: Phase
|
|
|
+"KI" = Top Exhaust Indoor
|
|
|
+"WO" = Front Exhaust Outdoor "1" = Single Phase
|
|
|
+"NO" = Top Exhaust Outdoor
|
|
|
+ Digit 20: Power Fusing (see Restriction 3)
|
|
|
+ "N" = None
|
|
|
+ Digits 8 - 10: Input Capacity in MBH "F" = Fusing
|
|
|
+"050", "075", "100", "125", "150", "175", "200", "250", "300", "350", "400"
|
|
|
+
|
|
|
+ Fuel Type Digit 22: Control Voltage
|
|
|
+
|
|
|
+Digit 11: "S" = 24VAC
|
|
|
+
|
|
|
+"N" = Natural Gas (Standard) Digit 23: Control Type (see Restriction 1)
|
|
|
+"P" = Propane
|
|
|
+
|
|
|
+Digits 12 - 13: Tube Material "T" = Two Stage High/Low with Thermostat (Standard)
|
|
|
+"SS" = 409 Stainless Steel (Standard) "S" = Single Stage On/Off with Thermostat
|
|
|
+"CS" = 304 Stainless Steel "E" = Modulating 5:1 (Natural Gas)/3:1 (Propane) with Thermostat
|
|
|
+ "W" = Modulating 10:1 (Natural Gas)/6:1 (Propane) with Thermostat
|
|
|
+Digit 14: Airflow Orientation "2" = Two Stage High/Low without Thermostat
|
|
|
+ "1" = Single Stage On/Off without Thermostat
|
|
|
+"H" = Horizontal "M" = Modulating 5:1 (Natural Gas)/3:1 (Propane) without Thermostat
|
|
|
+ "V" = Modulating 10:1 (Natural Gas)/6:1 (Propane) without Thermostat
|
|
|
+ Thermal Efficiency
|
|
|
+ Digit 15:
|
|
|
+"S" = 80%
|
|
|
+
|
|
|
+Digit 16: Elevation
|
|
|
+
|
|
|
+"S" = 0 - 2000' (Standard)
|
|
|
+"2" = 2001'- 3000'
|
|
|
+"3" = 3001' - 4000'
|
|
|
+"4" = 4001' - 5000'
|
|
|
+"5" = 5001' - 6000'
|
|
|
+"6" = 6001' - 7000'
|
|
|
+"Y" = 7001' and above
|
|
|
+
|
|
|
+*NOTE:
|
|
|
+Digits 3, 21, 24 & 25 are not used in this model.
|
|
|
+All heaters come with standard features: Air Proving Switch, Auxiliary High Temperature Limit Switch
|
|
|
+Descriptions of feature and options are found in the installation and operation manual.
|
|
|
+
|
|
|
+Restrictions:
|
|
|
+ 1: Control Type Code "V" & "W" not available with Input Capacity in MBH Codes "050", "075", "100", "125", "150" & "175".
|
|
|
+ 2: System/Inducer Voltage Code "2" not available with Input Capacity in MBH Codes "050", "075", "100", "125" , "150", "175" & "200".
|
|
|
+ 3. Power Fusing Code “F” only available with Disconnect Switch Code “D”. Power Fusing Code “F” always selected when Disconnect Switch Code “D” is selected.
|
|
|
+
|
|
|
+ GAS HEAT CONFIGURATION
|
|
|
+ For Technical SuppCoOrt DE-EmaCil:HRAenRewTaireSupport@renewaire.com
|
|
|
+
|
|
|
+ To Place an Order E-mail: RenewaireOrders@renewaire.com
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 143
|
|
|
+ORDERING & SUPPORT
|
|
|
+
|
|
|
+ INDOOR AIR QUALITY MATTERS
|
|
|
+
|
|
|
+ u Deficient IAQ is an EPA top-five health risk
|
|
|
+
|
|
|
+ u People spend 90% of their time indoors
|
|
|
+
|
|
|
+ u Indoor air can be 2-5 times and up to 100 times
|
|
|
+ more polluted than outdoor air
|
|
|
+
|
|
|
+BENEFITS OF INCREASED VENTILATION
|
|
|
+
|
|
|
+ BETTER IMPROVED INCREASED
|
|
|
+ HEALTH COGNITIVE PRODUCTIVITY
|
|
|
+ FUNCTION
|
|
|
+
|
|
|
+TECHNICAL/APPLICATIONS SUPPORT
|
|
|
+The goal of our technical-support team is to provide the BEST CUSTOMER SERVICE
|
|
|
+in the HVAC industry. You can count on our knowledgeable and seasoned staff for all your technical,
|
|
|
+application and service needs, and we’ll respond quickly and effectively to answer any of your questions.
|
|
|
+
|
|
|
+ CONTACT RENEWAIRE
|
|
|
+
|
|
|
+ PHONE: FOR TECHNICAL SUPPORT:
|
|
|
+ 1.800.627.4499 RenewaireSupport@renewaire.com
|
|
|
+
|
|
|
+ FAX: TO PLACE AN ORDER:
|
|
|
+ 608.221.2824 RenewaireOrders@renewaire.com
|
|
|
+
|
|
|
+144 RENEWAIRE.COM 1.800.627.4499
|
|
|
+RELEVANT RENEWAIRE
|
|
|
+
|
|
|
+EVERYWHERE TEMPERS THE AIR
|
|
|
+
|
|
|
+EVERY GEOGRAPHIC REGION Our ERVs moderate the extremes
|
|
|
+Our ERVs function perfectly across the world in every of outdoor supply-air temperature
|
|
|
+geographic region. and humidity year-round, providing
|
|
|
+ a sustainable solution for fresh air
|
|
|
+EVERY CLIMATE that feels like a perfect spring day.
|
|
|
+Our ERVs operate in every climate—from Alaska to
|
|
|
+Florida, and everywhere in between.
|
|
|
+
|
|
|
+EVERY PROJECT
|
|
|
+From massive skyscrapers to cozy residential homes,
|
|
|
+our ERVs can be used in every size project and in every
|
|
|
+code jurisdiction.
|
|
|
+
|
|
|
+APPLIED EVERYWHERE
|
|
|
+
|
|
|
+When indoor occupants breathe in unclean air, this harms their health and causes cognitive impairment. Our ERVs can
|
|
|
+provide cleaner and healthier indoor air for every type of building in the world, thus improving occupants’ wellbeing,
|
|
|
+while also reducing energy costs.
|
|
|
+
|
|
|
+RESIDENTIAL DAYCARE
|
|
|
+The increased airtightness of newer and remodeled Crowded daycare facilities breed deficient IAQ, thus
|
|
|
+homes is causing deficient IAQ, resulting in more health causing health problems for everyone—especially
|
|
|
+problems for indoor occupants. children who are more vulnerable.
|
|
|
+
|
|
|
+COMMERCIAL EDUCATION (LOWER AND HIGHER)
|
|
|
+As commercial buildings become more airtight, With students and teachers packed into tight classrooms,
|
|
|
+deficient IAQ is increasing and causing sickness, instances of deficient IAQ go up, resulting in academic
|
|
|
+absenteeism and decreased productivity. performance and test scores going down.
|
|
|
+
|
|
|
+H E A LT H C A R E GOVERNMENT
|
|
|
+The high occupant density of hospitals, nursing homes Aging and crowded government buildings result in
|
|
|
+and other healthcare facilities results in deficient IAQ deficient IAQ, which can impair worker performance
|
|
|
+and ensuing health problems for patients and staff alike. and productivity.
|
|
|
+
|
|
|
+RESTAURANTS/COFFEE SHOPS EVERY TYPE OF BUILDING
|
|
|
+The large volume of indoor occupants in restaurants Every type of building can benefit from the enhanced
|
|
|
+and coffee shops causes deficient IAQ and subsequent IAQ generated by RenewAire ERVs, including
|
|
|
+health problems. veterinary clinics, nail salons and manufacturing
|
|
|
+ facilities, among others.
|
|
|
+RETAIL
|
|
|
+The high level of foot traffic in retail stores leads
|
|
|
+to deficient IAQ and the potential sickness of shoppers,
|
|
|
+which can negatively impact sales.
|
|
|
+ RENEWAIRE EVERYWHERE LIT114_00 (01/19)
|
|
|
+
|
|
|
+ RenewAire ERVs can be applied everywhere across all
|
|
|
+ commercial, educational, institutional, light industrial
|
|
|
+
|
|
|
+ and residential buildings. Our technology excels in every
|
|
|
+ geographic region, every climate, and every size project.
|
|
|
+
|
|
|
+Member of the S&P Group
|
|
|
+Family of Brands
|
|
|
+ERV
|
|
|
+ LE SERIES
|
|
|
+
|
|
|
+ COMMERCIAL ERV CATALOG
|
|
|
+
|
|
|
+JANUARY 2019
|
|
|
+
|
|
|
+RENEWAIRE.COM | 800.627.4499
|
|
|
+BECAUSE INDOOR
|
|
|
+
|
|
|
+AIR QUALITY MATTERS
|
|
|
+
|
|
|
+As buildings become more airtight due to better application of ERV technologies. Deficient IAQ is a
|
|
|
+construction methodologies, the need for increased serious problem, especially considering:
|
|
|
+and balanced ventilation is critical. Without it, internally u On average, Americans spend 90% of their time indoors
|
|
|
+generated contaminants accumulate and cause deficient u The EPA found that indoor air may be 2-5 times—and
|
|
|
+indoor air quality (IAQ), which leads to significant
|
|
|
+health and cognitive problems for occupants. Industry occasionally greater than 100 times—more polluted
|
|
|
+standards are changing to combat deficient IAQ, and than outdoor air
|
|
|
+codes that adopt these new standards are driving the u The EPA ranks indoor air pollutants as a top-five
|
|
|
+ environmental health risk to occupants
|
|
|
+
|
|
|
+HEALTH PRODUCTIVITY LEARNING
|
|
|
+MAT TERS MAT TERS MAT TERS
|
|
|
+
|
|
|
+ADVERSE EFFECTS ABOUT RENEWAIRE
|
|
|
+
|
|
|
+O F DEFICIENT IAQ For over 30 years, RenewAire has been
|
|
|
+ a pioneer in enhancing IAQ in commercial and
|
|
|
+Deficient IAQ has numerous adverse effects on the residential buildings of every size. This is achieved
|
|
|
+health and cognitive function of building occupants. while maximizing sustainability through our fifth-
|
|
|
+ generation, enthalpic-core, static-plate Energy
|
|
|
+ Health problems: Acute allergies, Recovery Ventilators (ERVs) that optimize energy
|
|
|
+ headaches, coughs, asthma, skin efficiency, lower capital costs via HVAC load
|
|
|
+ irritations and breathing difficulties, reduction and decrease operational expenses
|
|
|
+ as well as chronic illnesses such as by minimizing equipment needs, resulting
|
|
|
+ cancer, liver disease, kidney damage in significant energy savings. Our ERVs are
|
|
|
+ and nervous-system failure. competitively priced, simple to install, easy to use
|
|
|
+ and maintain, have a quick payback and enjoy the
|
|
|
+ Cognitive impairment: Studies by the industry’s best warranty with the lowest claims
|
|
|
+ Harvard School of Public Health and the due to long-term reliability. In 2010, RenewAire
|
|
|
+ Lawrence Berkeley National Laboratory joined the Soler & Palau (S&P) Ventilation Group,
|
|
|
+ found that carbon dioxide (CO )—an providing direct access to the latest in energy-
|
|
|
+ efficient air-moving technologies. For more
|
|
|
+ 2 information, visit: renewaire.com.
|
|
|
+
|
|
|
+ indoor air contaminant—negatively impacted
|
|
|
+ thinking and decision-making at levels
|
|
|
+ commonly found inside homes and buildings.
|
|
|
+ TABLE OF CONTENTS
|
|
|
+
|
|
|
+ TABLE OF
|
|
|
+
|
|
|
+CONTENTS
|
|
|
+
|
|
|
+LE SERIES - Commercial Unitary ERV
|
|
|
+
|
|
|
+MODEL TYPE CFM RANGE PAGE
|
|
|
+LE6XINH - STANDARD Indoor 1,500-6,600 CFM 4-5
|
|
|
+LE6XINV - STANDARD Indoor 1,500-6,600 CFM 6-7
|
|
|
+LE6XRT - STANDARD Rooftop 1,500-6,600 CFM 8-10
|
|
|
+LE8XINH - STANDARD Indoor 2,000-8,800 CFM
|
|
|
+LE8XINV - STANDARD Indoor 2,000-8,800 CFM 12-13
|
|
|
+LE8XRT - STANDARD Rooftop 2,000-8,800 CFM 14-15
|
|
|
+LE10XINH - STANDARD Indoor 2,500-11,000 CFM 16-18
|
|
|
+LE10XINV - STANDARD Indoor 2,500-11,000 CFM 20-21
|
|
|
+LE10XRT - STANDARD Rooftop 2,500-11,000 CFM 22-23
|
|
|
+ 24-26
|
|
|
+
|
|
|
+ABOUT RENEWAIRE 2-3
|
|
|
+SPECIFICATIONS & DIMENSIONS 4-26
|
|
|
+OPTIONS & ACCESSORIES 27-39
|
|
|
+CERTIFICATIONS & PERFORMANCE
|
|
|
+ORDERING & SUPPORT 40
|
|
|
+ 41-44
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 1
|
|
|
+ ABOUT RENEWAIRE
|
|
|
+
|
|
|
+ R E N E WA I R E E R Vs
|
|
|
+
|
|
|
+ ACHIEVE SUSTAINABLE IAQ
|
|
|
+
|
|
|
+ RenewAire is a pioneer in enhancing IAQ while maximizing sustainability through enthalpic-core, static-plate Energy
|
|
|
+ Recovery Ventilators (ERVs) that optimize energy efficiency, lower costs by reducing HVAC loads and therefore
|
|
|
+ reduce environmental footprints. Our ERV technology preconditions incoming air with the otherwise-wasted energy
|
|
|
+ (heat and humidity) of the exhaust air going out—all while the airstreams are kept physically separate as certified by
|
|
|
+ the Air Conditioning, Heating and Refrigeration Institute (AHRI) for zero exhaust air transfer at normal balanced operating
|
|
|
+ conditions. As the pioneer of static-plate core technology in North America, RenewAire is the largest ERV producer in the USA.
|
|
|
+
|
|
|
+ OPTIMIZING OA COOLING SEASON RA OA HEATING SEASON RA
|
|
|
+ ENERGY EFFICIENCY
|
|
|
+ EFFICIENT EFFICIENT
|
|
|
+ Energy efficiency is optimized by preconditioning HEAT & HUMIDITY HEAT & HUMIDITY
|
|
|
+ the outside air coming in with the otherwise-wasted
|
|
|
+ heat and humidity of the exhaust air going out. This TRANSFER TRANSFER
|
|
|
+ exchange of energy moderates temperatures and moisture,
|
|
|
+ decreases HVAC equipment needs, drives operational EA FA EA FA
|
|
|
+ efficiencies and conserves energy.
|
|
|
+
|
|
|
+ REDUCING HVAC LOADS INSIDE OUTSIDE
|
|
|
+ Fresh Air Enters Stale Room Air Exits
|
|
|
+ RenewAire technology reduces HVAC loads during both winter and summer. In turn,
|
|
|
+ HVAC equipment size and needs can be decreased and furnaces and air conditioners Fixed Partition
|
|
|
+ can be smaller. This process ensures efficient operations and keeps both energy use and and Spacer Plates
|
|
|
+ costs low, while at the same time maintaining high-level IAQ.
|
|
|
+ (proprietary resin
|
|
|
+ and composite media) Outside Air
|
|
|
+
|
|
|
+ Stale Room Air
|
|
|
+
|
|
|
+ MINIMIZING ENVIRONMENTAL IMPACT
|
|
|
+
|
|
|
+ The combination of less energy used and HVAC loads being reduced conserves resources. Further, our Madison, WI plant
|
|
|
+ is 100% powered by renewable wind energy, and is one of the few buildings worldwide to be LEED and Green Globes
|
|
|
+ certified, as well as having achieved ENERGY STAR Building status. This commitment to sustainable manufacturing
|
|
|
+ minimizes our overall production and distribution environmental footprint.
|
|
|
+
|
|
|
+2
|
|
|
+ ABOUT RENEWAIRE
|
|
|
+
|
|
|
+WHY RENEWAIRE
|
|
|
+
|
|
|
+IS PREFERRED
|
|
|
+
|
|
|
+ BEST VALUE
|
|
|
+
|
|
|
+ u Priced competitively against other ERV models
|
|
|
+ u Due to competitive pricing and decreased costs, payback is short and ROI is maximized
|
|
|
+ u Contractors can pass these significant savings along to their customers
|
|
|
+
|
|
|
+ RELIABLE OPERATION
|
|
|
+
|
|
|
+ u Built-to-last ERVs have lifespans of 25+ years and operate consistently year-round in every extreme,
|
|
|
+ including frost-free performance in all but the most severe winter climates
|
|
|
+
|
|
|
+ u High-efficiency core operates dry in all conditions, meaning no condensate pans
|
|
|
+ u An industry-leading ten-year warranty for the static-plate core, two-year warranty for commercial
|
|
|
+
|
|
|
+ products and a five-year warranty for residential products
|
|
|
+ u Superior product quality results in paramount reliability and longevity
|
|
|
+
|
|
|
+ HIGHEST-QUALITY INDOOR AIR
|
|
|
+
|
|
|
+ u Stale indoor air is replaced with fresh, conditioned and filtered air from
|
|
|
+ the outside, resulting in Enhanced IAQ by removing harmful contaminants
|
|
|
+
|
|
|
+ u Airstreams do not mix and pollutants are not transferred across partition plates
|
|
|
+ u No biocide used; material does not promote biological growth
|
|
|
+ u Moderated temperatures and humidity maintain a comfortable indoor environment
|
|
|
+
|
|
|
+ OPTIMIZED ENERGY EFFICIENCY
|
|
|
+
|
|
|
+ u Efficient heat and humidity transfer recaptures up to 70-80% of the energy exhausted in the airstream
|
|
|
+ u Energy that’s otherwise wasted by conventional ventilation systems (such as bath fans) is reused,
|
|
|
+
|
|
|
+ thus dramatically reducing monthly operation costs
|
|
|
+ u Energy-efficient operation decreases HVAC loads, which cuts down on energy use and costs
|
|
|
+ u The hotter or colder the climate, the more energy is recovered
|
|
|
+
|
|
|
+ HIGHLY CERTIFIED
|
|
|
+
|
|
|
+ u See individual catalog submittal for certification details:
|
|
|
+ u UL u cUL u ETL u HVI u AHRI
|
|
|
+
|
|
|
+ 3
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HLE 6XINH Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS Options:
|
|
|
+ Spring vibration isolators
|
|
|
+ LE6XINV shown Ventilation Type: Onboard variable frequency drives (VFDs) -
|
|
|
+Download specification at: Static plate, heat and humidity transfer
|
|
|
+renewaire.com/specifications one or both airstreams
|
|
|
+AIRFLOW PERFORMANCE Typical Airflow Range: 1,500-6,600 CFM Shaft grounding ring on motors with VFDs
|
|
|
+ Fused disconnect
|
|
|
+ AHRI 1060 Certified Core: Six L125-G5 Integrated programmable controls -
|
|
|
+
|
|
|
+ Standard Features: enhanced, premium
|
|
|
+ TEFC Premium efficiency motors Class 1 low leakage motorized isolation dampers -
|
|
|
+ Motor starters
|
|
|
+ Non-fused disconnect OA, RA or both airstreams
|
|
|
+ 24 VAC transformer/relay package Qty. 2, Factory mounted filter alarms -
|
|
|
+ Cross-core differential pressure ports
|
|
|
+ both airstreams
|
|
|
+ Filters: Total qty. 12, MERV 8: 20" x 25" x 2" Double wall construction
|
|
|
+ Exterior paint - white, custom colors
|
|
|
+ Unit Dimensions & Weight:
|
|
|
+ 81 1/2" L x 125 1/2" W x 71 1/4" H Accessories:
|
|
|
+ Modular (per module) 943-1,367 lbs., varies by option(s) Filters - MERV 13, 2" or 4"; MERV 8, 4" (shipped loose)
|
|
|
+ Assembled (1-piece) 1,975-2,630 lbs., varies by option(s) Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): in exterior enclosure (TC7D-E)
|
|
|
+ Modular (2-modules) 80" L x 90" W x 78" H Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ Module 1 - 1,508 lbs., Module 2 - 1,406 lbs. wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ Assembled (1-piece) 160" L x 90" W x 78" H - IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ 2,630 lbs. duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+ Motor(s):
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ with choice of adjustable sheaves for low, Electric duct heater - EK series (1–175 kW)
|
|
|
+ medium or high blower speed (see table below) Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ External Static Pressure (in.w.g.)
|
|
|
+
|
|
|
+Airflow 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00
|
|
|
+ CFM BHP RPM BHP RPM
|
|
|
+ BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM
|
|
|
+ 1500 2.1 770 2.0 780
|
|
|
+ 2000 2.4 810 2.2 820 3 HP LOW SPEED 3 HP MED SPEED 3 HP HIGH SPEED
|
|
|
+ 2500 2.7 850 2.5 850
|
|
|
+ 3000 3.0 880 2.8 890 0.9 820 1.1 900 1.3 960 1.4 1020 1.6 1080
|
|
|
+ 3500 3.4 910 3.2 920
|
|
|
+ 3750 3.8 950 3.5 950 1.1 850 1.3 930 1.5 990 1.7 1050 1.9 1100
|
|
|
+ 4000 4.2 980 3.9 980
|
|
|
+ 4250 4.6 1000 4.3 1000 1.1 770 1.3 870 1.5 950 1.7 1010 1.9 1060 2.1 1110
|
|
|
+ 4500 5.1 1030 4.8 1030
|
|
|
+ 4750 5.3 1040 5.2 1060 1.4 800 1.6 890 1.8 960 2.0 1020 2.2 1080 2.4 1130
|
|
|
+ 5000 5.4 1070
|
|
|
+ 5250 Therm1a.7l Perf8o4r0manc1e.9Ratin9g1s0G5 220.15.2.x9l8sx0 2.4 1040 2.6 61C0o90res (I2O.8M) 1140
|
|
|
+ 5500
|
|
|
+ 5750 1.7 780 1.9 860 2.1 920 2.3 990 2.6 1040 2.8 1100 3.1 1150 5 HP
|
|
|
+ 6000 MED
|
|
|
+ 6250 1.9 810 2.1 880 2.3 940 2.6 1000 2.8 1050 3.0 1110 3.3 1160 SPEED
|
|
|
+ 6500 3.0 1060 3.3 1120 3.6 1170
|
|
|
+ 6600 2.2 840 2.3 900 2.6 960 2.8 1010
|
|
|
+
|
|
|
+ 3 HP 2.4 870 2.6 920 2.8 970 3.1 1030 3.3 1080 3.6 1130 3.9 1180
|
|
|
+ LOW
|
|
|
+ SPEED 2.7 900 2.9 950 3.1 990 3.3 1040 3.6 1090 3.9 1140 4.2 1190 5 HP
|
|
|
+
|
|
|
+ 5 HP 3.0 930 3.2 970 3.4 1010 3.7 1060 3.9 1110 4.2 1150 4.5 1210 HIGH
|
|
|
+ LOW
|
|
|
+ SPEED 3.4 960 3.5 990 3.8 1030 4.0 1080 4.3 1120 4.6 1170 4.9 1220 SPEED
|
|
|
+
|
|
|
+ 3.7 980 3.9 1020 4.1 1060 4.4 1100 4.7 1140 5.0 1190 5.4 1240
|
|
|
+
|
|
|
+ 4.1 1010 4.3 1040 4.5 1080 4.8 1120 5.1 1160 5.4 1200 5.8 1260
|
|
|
+
|
|
|
+ 4.5 1030 4.7 1070 5.0 1100 5.2 1140 5.5 1180 5.9 1220 6.3 1270
|
|
|
+
|
|
|
+ 5.0 1060 5.2 1090 5.4 1120 5.7 1160 6.0 1190 6.3 1240 6.8 1290
|
|
|
+
|
|
|
+ 5.4 1080 5.6 1110 5.9 1140 6.2 1170 6.5 1210 6.8 1250 7.3 1300
|
|
|
+
|
|
|
+ 5.6 1090 5.8 1120 6.1 1150 6.4 1180 6.7 1220 7.0 1260 7.5 1310
|
|
|
+
|
|
|
+ 7.5 HP LOW SPEED 7.5 HP MED SPEED
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+ 1000 2000 3000 4000 5000 6000 7000
|
|
|
+ Max. Max. Effectiveness (%) 90%
|
|
|
+
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Overcurrent FLA Min. Cir. Overcurrent 70%
|
|
|
+ per motor Amps Protection per motor Amps Protection
|
|
|
+ 50%
|
|
|
+ Device Device
|
|
|
+ 30%
|
|
|
+3.0 208-230 60 Single 14.7-14 33.1 40 9.38-8.48 40.2 45 At AHRI 1060 standard conditions.
|
|
|
+ See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+ 208-230 60 Three 9.38-8.48 21.1 25 9.38-8.48 23.2 25
|
|
|
+
|
|
|
+3.0 460 60 Three 4.24 9.5 15 4.24 10.5 15
|
|
|
+
|
|
|
+ 575 60 Three 3.3 7.4 15 3.3 8.2 15
|
|
|
+
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 45 14.5-13.4 35.9 45
|
|
|
+
|
|
|
+5.0 460 60 Three 6.7 15.1 20 6.7 16.6 20
|
|
|
+
|
|
|
+ 575 60 Three 5.3 11.9 15 5.3 13.1 15
|
|
|
+
|
|
|
+ 208-230 60 Three 21.0-19.0 47.3 60 21.0-19.0 52.0 60
|
|
|
+
|
|
|
+7.5 460 60 Three 9.5 21.4 25 9.5 23.5 25
|
|
|
+
|
|
|
+ 575 60 Three 7.6 17.1 20 7.6 18.8 20
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+4 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ LE6XINH Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ 69 3/4" Minimum ABBREVIATIONS
|
|
|
+ Service Area EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ Door Door RA: Room Air to be exhausted
|
|
|
+ Swing Swing FA: Fresh Air to inside
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ EA OA Unit must be installed in orientation
|
|
|
+ shown.
|
|
|
+ FA RA NOTE
|
|
|
+ 1.UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2.SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3. MIN. DUCT CLEARANCE
|
|
|
+ FROM DAMPER BLADES WHEN FULLY
|
|
|
+ OPENED TO BE 2". SMACNA RULES
|
|
|
+ APPLY.
|
|
|
+
|
|
|
+ 36" E-Box Door Door 60 1/4" Minimum
|
|
|
+ Minimum Swing Swing Blower Service
|
|
|
+ Service Area
|
|
|
+ Area Typ.
|
|
|
+ OA Inlet
|
|
|
+ 13 3/8" X 15 1/2" 111" Minimum 32" X 24" OA Damper
|
|
|
+ Service Area Duct Receiving Location
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 5 Electrical Flange (Optional)
|
|
|
+ TOP VIEW
|
|
|
+ 32" X 24" Connection 44 5/8"
|
|
|
+ 81 1/2" Overall
|
|
|
+ Duct Receiving Cover 25 1/4" 5" Damper 125 3/8" Overall
|
|
|
+ E-Box Frames Typ. 122 5/8" Case
|
|
|
+ Flange Typ. Pressure
|
|
|
+ Disconnect EA Ports (4) Typ.
|
|
|
+ 71 1/8" Overall Switch RA Damper
|
|
|
+ 69 5/8" Case OA Location
|
|
|
+ 41 3/8" (Optional)
|
|
|
+ 8 3/4"
|
|
|
+ 53 1/2" 8 3/4" 41 1/2"
|
|
|
+
|
|
|
+ FA RA
|
|
|
+
|
|
|
+ 25 1/4" CL 11 3/8" 29 5/8" 2" Duct Flange 69 1/8" Case 4" RA Inlet 25 1/4"
|
|
|
+ (5) 1 1/8" 2" Typ. 32" X 24"
|
|
|
+ Knockouts Typ. CL 73 3/8" Duct Receiving
|
|
|
+ CL 5 1/4" CL 2 1/4" Lift Lugs 25 1/4" Flange
|
|
|
+ (2) 7/8" Wiring
|
|
|
+ Knockouts FRONT VIEW
|
|
|
+
|
|
|
+ LEFT VIEW RIGHT VIEW
|
|
|
+ MDAArovaIaRdiwlaFebiLlnel:OagLsWEsTh6yoCwXpOnIeNiNn:HdFUimIGneniUtsiRoDnAidmTraIwOeinNng.sion
|
|
|
+ Version: MAY18 UNIT MOUNTING & APPLICATION
|
|
|
+
|
|
|
+ Must be mounted as shown. RA/EA airstream can
|
|
|
+ be switched with OA/FA airstream unless certain
|
|
|
+ options are selected.
|
|
|
+
|
|
|
+ LE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HLE 6XINV Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Spring vibration isolators
|
|
|
+ Onboard variable frequency drives (VFDs) -
|
|
|
+AIRFLOW PERFORMANCE Typical Airflow Range: 1,500-6,600 CFM
|
|
|
+ one or both airstreams
|
|
|
+ AHRI 1060 Certified Core: Six L125-G5 Shaft grounding ring on motors with VFDs
|
|
|
+ Fused disconnect
|
|
|
+ Standard Features: Integrated programmable controls -
|
|
|
+ TEFC Premium efficiency motors
|
|
|
+ Motor starters enhanced, premium
|
|
|
+ Non-fused disconnect Class 1 low leakage motorized isolation dampers -
|
|
|
+ 24 VAC transformer/relay package
|
|
|
+ Cross-core differential pressure ports OA, RA or both airstreams
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+ Filters: Total qty. 12, MERV 8: 20" x 25" x 2"
|
|
|
+ both airstreams
|
|
|
+ Unit Dimensions & Weight: Double wall construction
|
|
|
+ 81 1/2" L x 125 1/2" W x 71 1/4" H Exterior paint - white, custom colors
|
|
|
+ Modular (per module) 715-1,622 lbs., varies by option(s)
|
|
|
+ Assembled (1-piece) 1,984-2,640 lbs., varies by option(s) Accessories:
|
|
|
+ Filters - MERV 13, 2" or 4"; MERV 8, 4" (shipped loose)
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Digital time clock - wall mount (TC7D-W),
|
|
|
+ Modular (2-modules) 80" L x 90" W x 78" H
|
|
|
+ in exterior enclosure (TC7D-E)
|
|
|
+ Module 1 - 1,763 lbs., Module 2 - 1,159 lbs. Carbon dioxide sensor/control -
|
|
|
+ Assembled (1-piece) 160" L x 90" W x 78" H -
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ 2,922 lbs. IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ Motor(s): duct mount (IAQ-D)
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ with choice of adjustable sheaves for low, ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ medium or high blower speed (see table below) Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ External Static Pressure (in.w.g.)
|
|
|
+
|
|
|
+Airflow 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00
|
|
|
+ CFM BHP RPM BHP RPM
|
|
|
+ BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM
|
|
|
+ 1500 2.0 780
|
|
|
+ 2000 2.2 820 3 HP LOW SPEED 3 HP MED SPEED 3 HP HIGH SPEED
|
|
|
+ 2500 2.5 850
|
|
|
+ 3000 2.8 890 0.9 820 1.1 900 1.3 960 1.4 1020 1.6 1080
|
|
|
+ 3500 3.2 920
|
|
|
+ 3750 3.5 950 1.1 850 1.3 930 1.5 990 1.7 1050 1.9 1100
|
|
|
+ 4000 3.9 980
|
|
|
+ 4250 4.3 1000 1.1 770 1.3 870 1.5 950 1.7 1010 1.9 1060 2.1 1110
|
|
|
+ 4500 4.8 1030
|
|
|
+ 4750 5.2 1060 1.4 800 1.6 890 1.8 960 2.0 1020 2.2 1080 2.4 1130
|
|
|
+ 5000 5.4 1070 Therm1a.l7Perfo84rm0 ance1.9Rating91s0G5 202.115.2.x9ls8x0 2.4 1040 2.6 61C0o9r0es (IO2.8M) 1140
|
|
|
+ 5250
|
|
|
+ 5500 1.7 780 1.9 860 2.1 920 2.3 990 2.6 1040 2.8 1100 3.1 1150 5 HP
|
|
|
+ 5750 MED
|
|
|
+ 6000 1.9 810 2.1 880 2.3 940 2.6 1000 2.8 1050 3.0 1110 3.3 1160 SPEED
|
|
|
+ 6250 3.0 1060 3.3 1120 3.6 1170
|
|
|
+ 6500 2.2 840 2.3 900 2.6 960 2.8 1010
|
|
|
+ 6600
|
|
|
+ 3 HP 2.1 770 2.4 870 2.6 920 2.8 970 3.1 1030 3.3 1080 3.6 1130 3.9 1180
|
|
|
+ LOW
|
|
|
+ SPEED 2.4 810 2.7 900 2.9 950 3.1 990 3.3 1040 3.6 1090 3.9 1140 4.2 1190 5 HP
|
|
|
+ 2.7 850
|
|
|
+ 3.0 930 3.2 970 3.4 1010 3.7 1060 3.9 1110 4.2 1150 4.5 1210 HIGH
|
|
|
+
|
|
|
+ 3.0 880 3.4 960 3.5 990 3.8 1030 4.0 1080 4.3 1120 4.6 1170 4.9 1220 SPEED
|
|
|
+
|
|
|
+ 5 HP 3.4 910 3.7 980 3.9 1020 4.1 1060 4.4 1100 4.7 1140 5.0 1190 5.4 1240
|
|
|
+ LOW
|
|
|
+ SPEED 3.8 950 4.1 1010 4.3 1040 4.5 1080 4.8 1120 5.1 1160 5.4 1200 5.8 1260
|
|
|
+ 4.2 980
|
|
|
+ 4.5 1030 4.7 1070 5.0 1100 5.2 1140 5.5 1180 5.9 1220 6.3 1270
|
|
|
+
|
|
|
+ 4.6 1000 5.0 1060 5.2 1090 5.4 1120 5.7 1160 6.0 1190 6.3 1240 6.8 1290
|
|
|
+
|
|
|
+ 5.1 1030 5.4 1080 5.6 1110 5.9 1140 6.2 1170 6.5 1210 6.8 1250 7.3 1300
|
|
|
+
|
|
|
+ 5.3 1040 5.6 1090 5.8 1120 6.1 1150 6.4 1180 6.7 1220 7.0 1260 7.5 1310
|
|
|
+
|
|
|
+ 7.5 HP LOW SPEED 7.5 HP MED SPEED
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit. CORE PERFORMANCE
|
|
|
+ELECTRICAL DATA
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+ 1000 2000 3000 4000 5000 6000 7000
|
|
|
+ Max. Max. Effectiveness (%) 90%
|
|
|
+
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Overcurrent FLA Min. Cir. Overcurrent 70%
|
|
|
+ per motor Amps Protection per motor Amps Protection
|
|
|
+ 50%
|
|
|
+ Device Device
|
|
|
+ 30%
|
|
|
+3.0 208-230 60 Single 14.7-14 33.1 40 9.38-8.48 40.2 45 At AHRI 1060 standard conditions.
|
|
|
+ See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+ 208-230 60 Three 9.38-8.48 21.1 25 9.38-8.48 23.2 25
|
|
|
+
|
|
|
+3.0 460 60 Three 4.24 9.5 15 4.24 10.5 15
|
|
|
+
|
|
|
+ 575 60 Three 3.3 7.4 15 3.3 8.2 15
|
|
|
+
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 45 14.5-13.4 35.9 45
|
|
|
+
|
|
|
+5.0 460 60 Three 6.7 15.1 20 6.7 16.6 20
|
|
|
+
|
|
|
+ 575 60 Three 5.3 11.9 15 5.3 13.1 15
|
|
|
+
|
|
|
+ 208-230 60 Three 21.0-19.0 47.3 60 21.0-19.0 52.0 60
|
|
|
+
|
|
|
+7.5 460 60 Three 9.5 21.4 25 9.5 23.5 25
|
|
|
+
|
|
|
+ 575 60 Three 7.6 17.1 20 7.6 18.8 20
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+6 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ LE6XINV Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ 69 3/4" Minimum ABBREVIATIONS
|
|
|
+ Service Area EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ Door Door 34" RA: Room Air to be exhausted
|
|
|
+ Swing Swing Minimum FA: Fresh Air to inside
|
|
|
+ Service Area INSTALLATION ORIENTATION
|
|
|
+ Unit must be installed in orientation
|
|
|
+ RA OA shown.
|
|
|
+ NOTE
|
|
|
+ FA EA 1.UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2.SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3.MIN. DUCT CLEARANCE FROM
|
|
|
+ DAMPER BLADES WHEN FULLY
|
|
|
+ OPENED TO BE 2". SMACNA RULES
|
|
|
+ APPLY.
|
|
|
+
|
|
|
+ 36" E-Box Door Door 60 1/4" Minimum
|
|
|
+ Minimum Swing Swing Blower Service
|
|
|
+ Service Area
|
|
|
+ Area Typ.
|
|
|
+ 13 3/8" X 15 1/2" OA Inlet
|
|
|
+ RA Inlet RA Damper Electrical 111" Minimum 32" X 24"
|
|
|
+ 32" X 24" Location Connection Service Area Duct Receiving
|
|
|
+ Duct Receiving (Optional) Cover Flange
|
|
|
+ TOP VIEW
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 7 Flange 44 5/8" 125 3/8" Overall
|
|
|
+ 122 5/8" Case
|
|
|
+ 25 1/4" Pressure 81 1/2" Overall 32" X 24"
|
|
|
+ E-Box Ports (4) Typ. Duct Receiving
|
|
|
+ Disconnect 5" Damper
|
|
|
+ Switch Frames Typ. Flange Typ.
|
|
|
+
|
|
|
+ 71 1/8" Overall RA OA 25 1/4"
|
|
|
+ 69 5/8" Case
|
|
|
+ 41 1/2" 53 1/2" FA EA 8 3/4" 41 1/2"
|
|
|
+ 8 3/4"
|
|
|
+ 25 1/4" CL 11 3/8" 29 5/8" 2" 69 1/8" Case 4" OA Damper 25 1/4"
|
|
|
+ (5) 1 1/8" CL 2 1/4" 2" Typ. Location
|
|
|
+ Knockouts CL 5 1/4" Wiring CL 73 3/8" (Optional)
|
|
|
+ (2) 7/8" Lift Lugs
|
|
|
+
|
|
|
+ Knockouts
|
|
|
+
|
|
|
+ LEFT VIEW FRONT VIEW RIGHT VIEW
|
|
|
+ MDroaAAdvwIaReilianFlb:LlgeLOaETsW6yshXpoCIweNOn:ViNnUdFnimIGitenUDsiRoinmAdTreaIwOninNsgi.on
|
|
|
+ Version: MAY18 UNIT MOUNTING & APPLICATION
|
|
|
+ Must be mounted as shown. RA/EA airstream can
|
|
|
+ be switched with OA/FA airstream unless certain
|
|
|
+ options are selected.
|
|
|
+
|
|
|
+ LE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HLE 6XRT Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+ROOFTOP UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+ LE10XRT shown Ventilation Type: Options:
|
|
|
+Download specification at: Static plate, heat and humidity transfer Spring vibration isolators
|
|
|
+renewaire.com/specifications Onboard variable frequency drives (VFDs) -
|
|
|
+ Typical Airflow Range: 1,500-6,600 CFM
|
|
|
+AIRFLOW PERFORMANCE one or both airstreams
|
|
|
+ AHRI 1060 Certified Core: Six L125-G5 Shaft grounding ring on motors with VFDs
|
|
|
+ Fused disconnect
|
|
|
+ Standard Features: Integrated programmable controls -
|
|
|
+ TEFC Premium efficiency motors
|
|
|
+ Motor starters enhanced, premium
|
|
|
+ Non-fused disconnect Class 1 low leakage motorized isolation dampers -
|
|
|
+ 24 VAC transformer/relay package
|
|
|
+ Cross-core differential pressure ports OA, RA or both airstreams
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+ Filters:
|
|
|
+ Total qty. 12, MERV 8: 20" x 25" x 2" both airstreams
|
|
|
+ Double wall construction
|
|
|
+ Unit Dimensions & Weight: Exterior paint - white, custom colors
|
|
|
+ 111 1/4" L x 125 1/2" W x 71 1/4" H
|
|
|
+ Modular (per module) 1,069-1,461 lbs., varies by option(s) Accessories:
|
|
|
+ Assembled (1-piece) 2,086-2,753 lbs., varies by option(s) Filters - MERV 13, 2" or 4"; MERV 8, 4" (shipped loose)
|
|
|
+ Roof curb - standard 14"
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Curb wind clip
|
|
|
+ Modular (2-modules) 80" L x 90" W x 78" H Engineered combo curb for Carrier RTU
|
|
|
+ Engineered combo curb for Trane RTU
|
|
|
+ Module 1 - 1,602 lbs., Module 2 - 1,491 lbs. Digital time clock - wall mount (TC7D-W),
|
|
|
+ Assembled (1-piece) 160" L x 90" W x 78" H -
|
|
|
+ in exterior enclosure (TC7D-E)
|
|
|
+ 3,035 lbs. Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ Motor(s): wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ with choice of adjustable sheaves for low, duct mount (IAQ-D)
|
|
|
+ medium or high blower speed (see table below) Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ External Static Pressure (in.w.g.)
|
|
|
+
|
|
|
+Airflow 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00
|
|
|
+ CFM
|
|
|
+ BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM
|
|
|
+
|
|
|
+ 3 HP LOW SPEED 3 HP MED SPEED 3 HP HIGH SPEED
|
|
|
+
|
|
|
+1500 0.9 840 1.1 920 1.5 990 1.9 1060 2.4 1120
|
|
|
+
|
|
|
+2000 0.9 770 1.1 860 1.4 940 1.7 1010 2.2 1080 2.6 1140
|
|
|
+
|
|
|
+2500 1.1 800 1.3 880 1.7 950 2.0 1030 2.4 1090 2.9 1150
|
|
|
+
|
|
|
+3000 Therm1.4al Per8f3o0rman1c.e7 Rating9s00G5 2021.50.2.xl9s7x0 2.3 1040 2.7 1611C0ore3s.1(IOM11)70 5 HP MED
|
|
|
+
|
|
|
+3500 1.6 800 1.8 870 2.1 930 2.4 1000 2.7 1060 3.1 1120 3.5 1190
|
|
|
+
|
|
|
+3750 1.6 760 1.8 820 2.0 890 2.3 950 2.6 1010 2.9 1070 3.3 1130 3.7 1190
|
|
|
+
|
|
|
+4000 1.8 790 2.0 850 2.3 910 2.5 970 2.8 1030 3.2 1090 3.5 1150 3.9 1200 5 HP HIGH
|
|
|
+ 990 3.1 1040 3.4 1100 3.7 1160 4.1 1210 SPEED
|
|
|
+4250 3 HP 1.9 770 2.1 820 2.3 880 2.5 930 2.8
|
|
|
+ LOW
|
|
|
+4500 SPEED 2.2 800 2.4 850 2.6 900 2.8 960 3.1 1010 3.4 1060 3.7 1110 4.0 1170 4.3 1230
|
|
|
+4750 2.5 840 2.7 880 2.9 930 3.1 980 3.4
|
|
|
+ 1030 3.7 1080 4.0 1130 4.3 1180 4.6 1240
|
|
|
+
|
|
|
+5000 2.8 870 3.0 910 3.2 960 3.5 1000 3.7 1050 4.0 1100 4.3 1150 4.6 1200 4.9 1250
|
|
|
+
|
|
|
+5250 3.2 910 3.4 940 3.6 990 3.8 1030 4.1 1070 4.3 1120 4.6 1170 4.9 1220 5.3 1270
|
|
|
+
|
|
|
+5500 5 HP 3.6 940 3.8 970 4.0 1010 4.2 1050 4.5 1090 4.7 1140 5.0 1180 5.3 1230 5.6 1290
|
|
|
+
|
|
|
+5750 LOW 4.0 970 4.2 1000 4.4 1040 4.6 1080 4.9 1120 5.1 1160 5.4 1200 5.7 1250 6.0 1300
|
|
|
+
|
|
|
+6000 SPEED 4.4 1000 4.6 1030 4.8 1070 5.0 1100 5.3 1140 5.5 1180 5.8 1230 6.1 1270 6.4 1330
|
|
|
+
|
|
|
+6250 4.9 1030 5.1 1060 5.3 1090 5.5 1130 5.7 1160 6.0 1200 6.2 1250 6.5 1300 6.9 1350
|
|
|
+
|
|
|
+6500 5.3 1060 5.5 1090 5.7 1120 6.0 1150 6.2 1190 6.4 1230 6.7 1270 7.0 1320 7.4 1380
|
|
|
+
|
|
|
+6600 5.5 1070 5.7 1100 5.9 1130 6.1 1160 6.4 1200 6.6 1240 6.9 1280 7.2 1330 7.5 1390
|
|
|
+
|
|
|
+ 7.5 HP LOW SPEED 7.5 HP MED SPEED
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit. CORE PERFORMANCE
|
|
|
+ELECTRICAL DATA
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+ Max. Max. Effectiveness (%) 1000 2000 3000 4000 5000 6000 7000
|
|
|
+ 90%
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Overcurrent FLA Min. Cir. Overcurrent
|
|
|
+ per motor Amps Protection per motor Amps Protection 70%
|
|
|
+
|
|
|
+ Device Device
|
|
|
+
|
|
|
+3.0 208-230 60 Single 14.7-14 33.1 40 9.38-8.48 40.2 45
|
|
|
+
|
|
|
+ 208-230 60 Three 9.38-8.48 21.1 25 9.38-8.48 23.2 25 50%
|
|
|
+
|
|
|
+3.0 460 60 Three 4.24 9.5 15 4.24 10.5 15 30%
|
|
|
+ At AHRI 1060 standard conditions.
|
|
|
+ 575 60 Three 3.3 7.4 15 3.3 8.2 15 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 45 14.5-13.4 35.9 45
|
|
|
+
|
|
|
+5.0 460 60 Three 6.7 15.1 20 6.7 16.6 20
|
|
|
+
|
|
|
+ 575 60 Three 5.3 11.9 15 5.3 13.1 15
|
|
|
+
|
|
|
+ 208-230 60 Three 21.0-19.0 47.3 60 21.0-19.0 52.0 60
|
|
|
+
|
|
|
+7.5 460 60 Three 9.5 21.4 25 9.5 23.5 25
|
|
|
+
|
|
|
+ 575 60 Three 7.6 17.1 20 7.6 18.8 20
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+8 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ LE6XRT (RTV/RTR) Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ 69 3/4" Minimum ABBREVIATIONS
|
|
|
+ Service Area EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ CURB LE6X FA (RTV) Door Door RA RA: Room Air to be exhausted
|
|
|
+ 16 1/8" X 19 1/2" Swing Swing 24" X 32" FA: Fresh Air to inside
|
|
|
+ Opening RTV: Rooftop Vertical RA & FA
|
|
|
+ 64 1/4" O.D. Opening RTR: Rooftop Vertical RA Only
|
|
|
+ OA INSTALLATION ORIENTATION
|
|
|
+ A A EA Unit must be installed in orientation
|
|
|
+ OA shown.
|
|
|
+ 115 1/4" O.D. 9 1/2" 36" E-Box 49 5/8" NOTE:
|
|
|
+ 33" Minimum 18 3/8" 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ Service Area DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ 20" 25" NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ FA RA 46" 41" TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ Minimum Area Typ. Door Door RA Damper CURB CROSS-SECTION A-A (TYP.)
|
|
|
+ Blower Service Swing Swing Location
|
|
|
+ 3" 60 1/4" (Optional)
|
|
|
+ 17 1/4" 60 1/2" I.D. 1 1/2" X 1/4" 1 7/8"
|
|
|
+ 19 5/8" Neoprene Gasket
|
|
|
+ TOP VIEW Typ.
|
|
|
+ 111" Minimum 3/4" X 3 1/2"
|
|
|
+ 13 3/8" X 15 1/2" Service Area Pressure Ports Wooden Nailer 14"
|
|
|
+ (4) Typ.
|
|
|
+ Electrical TOP VIEW 3"
|
|
|
+ 2" Typ.
|
|
|
+ Connection SECTION A-A
|
|
|
+ Cover
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 9 EA Outlet E-Box
|
|
|
+
|
|
|
+ Disconnect 111 1/8" Overall 125 3/8" Overall
|
|
|
+ 69 1/4" Case 122 5/8" Case
|
|
|
+ 44 5/8" 8 7/8" Switch 22 1/4"
|
|
|
+ 53 1/2"
|
|
|
+ 71 1/8" Overall
|
|
|
+ 65 5/8" Case FA RTR
|
|
|
+ 4" ONLY
|
|
|
+
|
|
|
+ FA (RTR) 25 1/4" CL 5 1/4" 2" Duct 73 3/8" OA Inlets,
|
|
|
+ 32" X 24" (2) 7/8" Flange Typ. Lifting Lugs OA Damper
|
|
|
+ Duct Receiving CL 11 3/8" Knockouts
|
|
|
+ Flange (5) 7/8" Locations
|
|
|
+ Knockouts FA (Optional)
|
|
|
+ RTV RA
|
|
|
+ ONLY RIGHT VIEW
|
|
|
+
|
|
|
+ LEFT VIEW HERT except 6x 8x, LERT HERT except 6x 8x, LERT UNIT MOUNTING & APPLICATION
|
|
|
+ Must be mounted as shown. Airstreams can not
|
|
|
+ FRONT VIEW be switched.
|
|
|
+
|
|
|
+ MoAdIReFl:LLOEW6XCORTNVF/IGRUTRRATION RTV RTR
|
|
|
+ DraAwvailianblge asTsyhpowen:: Unit Dimension
|
|
|
+ EA OA EA OA
|
|
|
+
|
|
|
+ Version: MAY18 FA
|
|
|
+
|
|
|
+ FA RA
|
|
|
+ RA
|
|
|
+
|
|
|
+ LE-SERIES
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+10 RENEWAIRE.COM 1.800.627.4499
|
|
|
+LE6XRT (RTH/RTF) Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ 69 3/4" Minimum ABBREVIATIONS
|
|
|
+ Service Area EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ CURB LE6X RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ 64 1/4" O.D. FA ( RTF) Door Door RTF: Rooftop Vertical FA Only
|
|
|
+ 16 1/8" X 19 1/2" Swing Swing RTH: Rooftop Horizontal RA & FA
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ A A Opening Unit must be installed in orientation
|
|
|
+ shown.
|
|
|
+ 115 1/4" O.D. 9 1/2" EA OA NOTE:
|
|
|
+ 33" OA 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ 20" 25" 36" E-Box 18 3/8" DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ Minimum NEAREST EIGHTH OF AN INCH.
|
|
|
+ FA RA Service Area 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ 46"
|
|
|
+
|
|
|
+ 17 1/4" 3" Minimum Area Typ. Door Door CURB CROSS-SECTION A-A (TYP.)
|
|
|
+ 60 1/2" I.D. Blower Service Swing Swing
|
|
|
+ 60 1/4"
|
|
|
+ TOP VIEW 1 1/2" X 1/4" 1 7/8"
|
|
|
+ Neoprene Gasket
|
|
|
+
|
|
|
+ 111" Minimum 3/4" X 3 1/2"
|
|
|
+ Service Area Wooden Nailer
|
|
|
+
|
|
|
+ TOP VIEW 3"
|
|
|
+ 13 3/8" X 15 1/2" 8 3/4"
|
|
|
+ 111 1/8" Overall 14"
|
|
|
+ Electrical 69 1/4" Case SECTION A-A
|
|
|
+
|
|
|
+ Connection
|
|
|
+
|
|
|
+EA Outlet Cover E-Box
|
|
|
+
|
|
|
+ Disconnect RA 125 3/8" Overall
|
|
|
+ 32" X 24" 122 5/8" Case
|
|
|
+ 44 5/8" 53 1/2" Switch 22 1/4" 19 5/8" Duct Receiving
|
|
|
+ Typ.
|
|
|
+71 1/8" Overall Flange
|
|
|
+ 65 5/8" Case Pressure Ports
|
|
|
+ 4" 8 3/4" (4) Typ.
|
|
|
+
|
|
|
+ FA RTH RA
|
|
|
+ ONLY
|
|
|
+
|
|
|
+FA (RTH) 25 1/4" CL 5 1/4" 2" Duct 73 3/8" 2" Typ. 25 3/8" OA Inlets,
|
|
|
+32" X 24" (2) 7/8" Flange Typ. Lifting Lugs OA Damper
|
|
|
+Duct Receiving CL 11 3/8" Knockouts 5" Damper RA Damper
|
|
|
+Flange (5) 7/8" FA Frames Typ. Location Locations
|
|
|
+ Knockouts (Optional) (Optional)
|
|
|
+ RTF
|
|
|
+ ONLY
|
|
|
+
|
|
|
+ LEFT VIEW HERT except 6x 8x, LERT FRONT VIEW HERTexcept 6x 8x, LERT RIGHT VIEW
|
|
|
+
|
|
|
+MoAdIReFl:LLOEW6XCORTNHF/IGRUTFRATION RTH RTF UNIT MOUNTING & APPLICATION
|
|
|
+DraAwvailianblge asTsyhpowen:: Unit Dimension Must be mounted as shown. Airstreams can not
|
|
|
+ EA OA EA OA be switched.
|
|
|
+ FA RA
|
|
|
+ RA
|
|
|
+Version: MAY18
|
|
|
+ FA
|
|
|
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 11
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HLE 8XINH Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+ LE8XINV shown Ventilation Type: Options:
|
|
|
+Download specification at: Static plate, heat and humidity transfer Spring vibration isolators
|
|
|
+renewaire.com/specifications Onboard variable frequency drives (VFDs) -
|
|
|
+ Typical Airflow Range: 2,000-8,800 CFM
|
|
|
+AIRFLOW PERFORMANCE one or both airstreams
|
|
|
+ AHRI 1060 Certified Core: Eight L125-G5 Shaft grounding ring on motors with VFDs
|
|
|
+ Fused disconnect
|
|
|
+ Standard Features: Integrated programmable controls -
|
|
|
+ TEFC Premium efficiency motors
|
|
|
+ Motor starters enhanced, premium
|
|
|
+ Non-fused disconnect Class 1 low leakage motorized isolation dampers -
|
|
|
+ 24 VAC transformer/relay package
|
|
|
+ Cross-core differential pressure ports OA, RA or both airstreams
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+ Filters: Total qty. 16, MERV 8: 20" x 25" x 2"
|
|
|
+ both airstreams
|
|
|
+ Unit Dimensions: Double wall construction
|
|
|
+ 80 1/2" L x 165" W x 71 1/4" H Exterior paint - white, custom colors
|
|
|
+ Modular (per module) 1,214-1,672 lbs., varies by option(s)
|
|
|
+ Assembled (1-piece) 2,479-3,279 lbs., varies by option(s) Accessories:
|
|
|
+ Filters - MERV 13, 2" or 4"; MERV 8, 4" (shipped loose)
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Digital time clock - wall mount (TC7D-W),
|
|
|
+ Modular (2-modules) 100" L x 90" W x 78" H
|
|
|
+ in exterior enclosure (TC7D-E)
|
|
|
+ Module 1 - 1,852 lbs., Module 2 - 1,789 lbs. Carbon dioxide sensor/control -
|
|
|
+ Assembled (1-piece) 200" L x 90" W x 78" H -
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ 3,638 lbs. IAQ sensor - wall mount (IAQ-W),
|
|
|
+
|
|
|
+ Motor(s): duct mount (IAQ-D)
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ with choice of adjustable sheaves for low, ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ medium or high blower speed (see table below) Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ External Static Pressure (in.w.g.)
|
|
|
+
|
|
|
+Airflow 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00
|
|
|
+ CFM
|
|
|
+ BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM
|
|
|
+ 3 HP MED
|
|
|
+ 3 HP LOW SPEED SPEED 3 HP HIGH SPEED
|
|
|
+
|
|
|
+2000 1.0 680 1.3 790 1.5 870 1.8 940 2.0 1000 2.2 1060
|
|
|
+
|
|
|
+3000 1.1 640 1.4 740 1.7 820 2.0 890 2.3 960 2.6 1020 2.9 1070
|
|
|
+
|
|
|
+4000 1.6 710 1.9 790 2.2 860 2.6 920 2.9 990 3.2 1040 3.6 1100 5 HP
|
|
|
+ HIGH
|
|
|
+4500 1.5 660 1.8 740 2.2 810 2.5 880 2.9 940 3.2 1000 3.6 1060 4.0 1110 SPEED
|
|
|
+
|
|
|
+5000 1.7 690 2.1 770 2.5 840 2.8 900 3.2 960 3.6 1020 4.0 1070 4.5 1130 7.5 HP
|
|
|
+
|
|
|
+5500 1.7 650 2.0 730 2.4 8T0h0erma2l.8Perfo8r6m0ance3.R2ating9s3G0 5 2031.65.2.xl9s8x0 4.0 1040 4.5 8 1C0o9r0es (IO4.M9 ) 1140 7.5 HP
|
|
|
+ HIGH
|
|
|
+6000 1.9 690 2.3 760 2.7 830 3.1 890 3.6 950 4.0 1010 4.5 1060 5.0 1110 5.5 1160 SPEED
|
|
|
+
|
|
|
+6250 3 HP 2.1 710 2.5 780 2.9 840 3.3 910 3.8 960 4.3 1020 4.7 1070 5.2 1120 5.7 1170
|
|
|
+ LOW
|
|
|
+6500 SPEED 2.3 720 2.7 790 3.1 860 3.6 920 4.0 980 4.5 1030 5.0 1080 5.5 1130 6.0 1180
|
|
|
+6750 2.4 740 2.9 810 3.3 870 3.8 930 4.3 990 4.8 1040 5.3 1100 5.8 1140 6.3 1190
|
|
|
+
|
|
|
+7000 2.6 760 3.1 830 3.5 890 4.0 950 4.5 1000 5.0 1060 5.6 1110 6.1 1160 6.6 1200
|
|
|
+
|
|
|
+7250 2.8 780 3.3 850 3.7 910 4.3 960 4.8 1020 5.3 1070 5.8 1120 6.4 1170 7.0 1210
|
|
|
+
|
|
|
+7500 3.0 800 3.5 860 4.0 920 4.5 980 5.0 1030 5.6 1080 6.2 1130 6.7 1180 7.3 1220
|
|
|
+
|
|
|
+7750 3.2 820 3.7 880 4.2 940 4.8 990 5.3 1050 5.9 1100 6.5 1140 7.1 1190
|
|
|
+
|
|
|
+8000 3.5 840 4.0 900 4.5 960 5.1 1010 5.6 1060 6.2 1110 6.8 1160 7.4 1200
|
|
|
+
|
|
|
+8250 5 HP 3.7 860 4.2 920 4.8 970 5.4 1030 5.9 1080 6.5 1120 7.1 1170
|
|
|
+
|
|
|
+8500 LOW 4.0 880 4.5 930 5.1 990 5.7 1040 6.3 1090 6.9 1140 7.5 1180
|
|
|
+
|
|
|
+8800 SPEED 4.3 900 4.9 960 5.5 1010 6.1 1060 6.7 1110 7.3 1150
|
|
|
+
|
|
|
+ 5 HP MED 7.5 HP LOW 7.5 HP MED SPEED
|
|
|
+ SPEED SPEED
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit. CORE PERFORMANCE
|
|
|
+ELECTRICAL DATA
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Max. FLA Min. Cir. Max. 2000 4000 6000 8000
|
|
|
+ per motor Amps Overcurrent per motor Amps Overcurrent 90%
|
|
|
+ Protection Protection Effectiveness (%)
|
|
|
+
|
|
|
+ Device Device
|
|
|
+
|
|
|
+3.0 208-230 60 Single 14.7-14 33.1 40 9.38-8.48 40.2 45 70%
|
|
|
+
|
|
|
+ 208-230 60 Three 9.38-8.48 21.1 25 9.38-8.48 23.2 25
|
|
|
+ 15
|
|
|
+3.0 460 60 Three 4.24 9.5 15 4.24 10.5 15 50%
|
|
|
+
|
|
|
+ 575 60 Three 3.3 7.4 45 3.3 8.2 15
|
|
|
+ 20
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 15 14.5-13.4 35.9 45 30%
|
|
|
+ At AHRI 1060 standard conditions.
|
|
|
+5.0 460 60 Three 6.7 15.1 60 6.7 16.6 20 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+ 25
|
|
|
+ 575 60 Three 5.3 11.9 20 5.3 13.1 15
|
|
|
+
|
|
|
+ 208-230 60 Three 21.0-19.0 47.3 21.0-19.0 52.0 60
|
|
|
+
|
|
|
+7.5 460 60 Three 9.5 21.4 9.5 23.5 25
|
|
|
+
|
|
|
+ 575 60 Three 7.6 17.1 7.6 18.8 20
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+12 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ LE8XINH Energy Recovery Ventilator Standard ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ 69 3/4" OA: Outside Air intake
|
|
|
+ Minimum RA: Room Air to be exhausted
|
|
|
+ Service Area FA: Fresh Air to inside
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ Door Door Unit must be installed in orientation
|
|
|
+ Swing Swing shown.
|
|
|
+ NOTE
|
|
|
+ EA OA 1.UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ FA RA NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2.SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3.MIN. DUCT CLEARANCE FROM
|
|
|
+ DAMPER BLADES WHEN FULLY
|
|
|
+ OPENED TO BE 2". SMACNA RULES
|
|
|
+ APPLY.
|
|
|
+
|
|
|
+ 36" E-Box Door Door
|
|
|
+ Minimum Swing Swing
|
|
|
+ Service Area
|
|
|
+
|
|
|
+ 111" Minimum 78 1/2"
|
|
|
+ Service Area Minimum
|
|
|
+
|
|
|
+ TOP VIEW Blower
|
|
|
+ Service
|
|
|
+ 80 3/8" Overall Area Typ.
|
|
|
+ 5" Damper
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 13 48" X 24" 13 3/8" X 15 1/2" E-Box RA Inlet OA Inlet
|
|
|
+ Duct Receiving Electrical Frames Typ. 48" X 24" 48" X 24"
|
|
|
+ Connection Disconnect Duct Receiving Duct Receiving
|
|
|
+ Flange Typ. Cover Switch EA Flange Flange
|
|
|
+
|
|
|
+ 64 5/8" Pressure 164 7/8" Overall OA Damper
|
|
|
+ Ports (4) Typ. Location
|
|
|
+ 27 3/4" 161 3/8" Case (Optional)
|
|
|
+ OA
|
|
|
+ 71 1/8" Overall
|
|
|
+ 69 5/8" Case 53 1/2" 4" 8 7/8" 41 5/8"
|
|
|
+ 41 1/8" Typ.
|
|
|
+
|
|
|
+ FA RA
|
|
|
+
|
|
|
+ 27 3/4" CL 11 3/8" 29 5/8" 2" 69 1/4" Case 2" Typ. RA Damper 27 3/8"
|
|
|
+ (5) 1 1/8 CL 2 1/4" CL 73 3/8" Location
|
|
|
+ Knockouts CL 5 1/4" Lift Lugs 27 3/8" (Optional)
|
|
|
+ (2) 7/8" Wiring
|
|
|
+ Knockouts FRONT VIEW RIGHT VIEW
|
|
|
+ LEFT VIEW
|
|
|
+
|
|
|
+ MAoIdReFLl:OLW E8CXOINNHFIGURATION UNIT MOUNTING & APPLICATION
|
|
|
+ DrAavawilabinlegas Tshyopwnein: dUimneintsiDonidmraweinngs. ion
|
|
|
+ Version: MAY18 Must be mounted as shown. RA/EA airstream can
|
|
|
+ be switched with OA/FA airstream unless certain
|
|
|
+ options are selected.
|
|
|
+
|
|
|
+ LE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HLE 8XINV Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Spring vibration isolators
|
|
|
+ Onboard variable frequency drives (VFDs) -
|
|
|
+AIRFLOW PERFORMANCE Typical Airflow Range: 2,000-8,800 CFM
|
|
|
+ one or both airstreams
|
|
|
+ AHRI 1060 Certified Core: Eight L125-G5
|
|
|
+ Shaft grounding ring on motors with VFDs
|
|
|
+ Standard Features: Fused disconnect
|
|
|
+ TEFC Premium efficiency motors Integrated programmable controls -
|
|
|
+ Motor starters
|
|
|
+ Non-fused disconnect enhanced, premium
|
|
|
+ 24 VAC transformer/relay package Class 1 low leakage motorized isolation dampers -
|
|
|
+ Cross-core differential pressure ports
|
|
|
+ OA, RA or both airstreams
|
|
|
+ Filters: Total qty. 16, MERV 8: 20" x 25" x 2" Qty. 2, Factory mounted filter alarms -
|
|
|
+
|
|
|
+ Unit Dimensions & Weight: both airstreams
|
|
|
+ 81 1/2" L x 165" W x 71 1/4" H Double wall construction
|
|
|
+ Modular (per module) 918-1,984 lbs., varies by option(s) Exterior paint - white, custom colors
|
|
|
+ Assembled (1-piece) 2,495-3,295 lbs., varies by option(s)
|
|
|
+ Accessories:
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Filters - MERV 13, 2" or 4"; MERV 8, 4" (shipped loose)
|
|
|
+ Modular (2-modules) 100" L x 90" W x 78" H Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ Module 1 - 2,164 lbs., Module 2 - 1,493 lbs. in exterior enclosure (TC7D-E)
|
|
|
+ Assembled (1-piece) 200" L x 90" W x 78" H - Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ 3,654 lbs. wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W),
|
|
|
+ Motor(s):
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+ with choice of adjustable sheaves for low,
|
|
|
+ medium or high blower speed (see table below) ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+ External Static Pressure (in.w.g.)
|
|
|
+
|
|
|
+Airflow 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00
|
|
|
+ CFM
|
|
|
+ BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM
|
|
|
+
|
|
|
+ 3 HP LOW SPEED 3 HP MED 3 HP HIGH SPEED
|
|
|
+ SPEED
|
|
|
+
|
|
|
+2000 1.0 680 1.3 790 1.5 870 1.8 940 2.0 1000 2.2 1060
|
|
|
+
|
|
|
+3000 1.1 640 1.4 740 1.7 820 2.0 890 2.3 960 2.6 1020 2.9 1070
|
|
|
+
|
|
|
+4000 1.6 710 1.9 790 2.2 860 2.6 920 2.9 990 3.2 1040 3.6 1100 5 HP
|
|
|
+ HIGH
|
|
|
+4500 1.5 660 1.8 740 2.2 810 2.5 880 2.9 940 3.2 1000 3.6 1060 4.0 1110 SPEED
|
|
|
+
|
|
|
+5000 1.7 690 2.1 770 2.5 840 2.8 900 3.2 960 3.6 1020 4.0 1070 4.5 1130 7.5 HP
|
|
|
+
|
|
|
+5500 1.7 650 2.0 730 2.4 8T0h0erma2l.8Perfo8r6m0ance3.R2ating9s3G0 5 2031.65.2.xl9s8x0 4.0 1040 4.5 8 1C0o9r0es (IO4.M9 ) 1140 7.5 HP
|
|
|
+ HIGH
|
|
|
+6000 1.9 690 2.3 760 2.7 830 3.1 890 3.6 950 4.0 1010 4.5 1060 5.0 1110 5.5 1160 SPEED
|
|
|
+
|
|
|
+6250 3 HP 2.1 710 2.5 780 2.9 840 3.3 910 3.8 960 4.3 1020 4.7 1070 5.2 1120 5.7 1170
|
|
|
+ LOW
|
|
|
+6500 SPEED 2.3 720 2.7 790 3.1 860 3.6 920 4.0 980 4.5 1030 5.0 1080 5.5 1130 6.0 1180
|
|
|
+6750 2.4 740 2.9 810 3.3 870 3.8 930 4.3 990 4.8 1040 5.3 1100 5.8 1140 6.3 1190
|
|
|
+
|
|
|
+7000 2.6 760 3.1 830 3.5 890 4.0 950 4.5 1000 5.0 1060 5.6 1110 6.1 1160 6.6 1200
|
|
|
+
|
|
|
+7250 2.8 780 3.3 850 3.7 910 4.3 960 4.8 1020 5.3 1070 5.8 1120 6.4 1170 7.0 1210
|
|
|
+
|
|
|
+7500 3.0 800 3.5 860 4.0 920 4.5 980 5.0 1030 5.6 1080 6.2 1130 6.7 1180 7.3 1220
|
|
|
+
|
|
|
+7750 3.2 820 3.7 880 4.2 940 4.8 990 5.3 1050 5.9 1100 6.5 1140 7.1 1190
|
|
|
+
|
|
|
+8000 3.5 840 4.0 900 4.5 960 5.1 1010 5.6 1060 6.2 1110 6.8 1160 7.4 1200
|
|
|
+
|
|
|
+8250 5 HP 3.7 860 4.2 920 4.8 970 5.4 1030 5.9 1080 6.5 1120 7.1 1170
|
|
|
+
|
|
|
+8500 LOW 4.0 880 4.5 930 5.1 990 5.7 1040 6.3 1090 6.9 1140 7.5 1180
|
|
|
+8800 SPEED 4.3 900 4.9 960 5.5 1010 6.1 1060 6.7 1110 7.3 1150
|
|
|
+
|
|
|
+ 5 HP MED 7.5 HP LOW 7.5 HP MED SPEED
|
|
|
+ SPEED SPEED
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Max. FLA Min. Cir. Max. 2000 4000 6000 8000
|
|
|
+ per motor Amps Overcurrent per motor Amps Overcurrent 90%
|
|
|
+ Protection Protection Effectiveness (%)
|
|
|
+
|
|
|
+ Device Device
|
|
|
+
|
|
|
+3.0 208-230 60 Single 14.7-14 33.1 40 9.38-8.48 40.2 45 70%
|
|
|
+
|
|
|
+ 208-230 60 Three 9.38-8.48 21.1 25 9.38-8.48 23.2 25
|
|
|
+ 15
|
|
|
+3.0 460 60 Three 4.24 9.5 15 4.24 10.5 15 50%
|
|
|
+
|
|
|
+ 575 60 Three 3.3 7.4 45 3.3 8.2 15
|
|
|
+ 20
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 15 14.5-13.4 35.9 45 30%
|
|
|
+ At AHRI 1060 standard conditions.
|
|
|
+5.0 460 60 Three 6.7 15.1 60 6.7 16.6 20 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+ 25
|
|
|
+ 575 60 Three 5.3 11.9 20 5.3 13.1 15
|
|
|
+
|
|
|
+ 208-230 60 Three 21.0-19.0 47.3 21.0-19.0 52.0 60
|
|
|
+
|
|
|
+7.5 460 60 Three 9.5 21.4 9.5 23.5 25
|
|
|
+
|
|
|
+ 575 60 Three 7.6 17.1 7.6 18.8 20
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+14 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ LE8XINV Energy Recovery Ventilator Standard ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ 69 3/4" Minimum OA: Outside Air intake
|
|
|
+ Service Area RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ Door Door INSTALLATION ORIENTATION
|
|
|
+ Swing Swing Unit must be installed in orientation
|
|
|
+ shown.
|
|
|
+ RA OA 34" NOTE
|
|
|
+ Minimum 1.UNLESS OTHERWISE SPECIFIED,
|
|
|
+ Service Area DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ FA EA 2.SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ 36" E-Box 3.DUCT CLEARANCE FROM DAMPER
|
|
|
+ Minimum BLADES WHEN FULLY OPENED TO BE
|
|
|
+ Service Area 2". SMACNA RULES
|
|
|
+ APPLY.
|
|
|
+
|
|
|
+ Door Door 78 1/2"
|
|
|
+ Swing Swing Minimum Blower
|
|
|
+
|
|
|
+ Service Area
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 15 RA Inlet 13 3/8" X 15 1/2" 111" Minimum OA Damper OA Inlet
|
|
|
+ 48" X 24" Electrical Service Area Location 48" X 24"
|
|
|
+ Duct Receiving Connection (Optional) Duct Receiving
|
|
|
+ Cover TOP VIEW Flange
|
|
|
+ Flange 164 7/8" Overall
|
|
|
+ 64 5/8" 81 1/2" Overall 161 3/8" Case
|
|
|
+ 26 1/4"
|
|
|
+ 27 3/4" E-Box 5" Damper
|
|
|
+ Frames Typ. Pressure
|
|
|
+ 71 1/8" Overall Disconnect Ports (4) Typ.
|
|
|
+ 69 5/8" Case Switch RA
|
|
|
+ OA
|
|
|
+
|
|
|
+ 53 1/2" 4" EA 9" 41 3/4"
|
|
|
+ Typ. Typ.
|
|
|
+ 2" Typ.
|
|
|
+ FA 2" Duct
|
|
|
+ Flange Typ.
|
|
|
+ RA Damper CL 11 3/8" 29 5/8" CL 5 1/4" CL 2 1/4" 69 1/4" Case 27 5/8" 48" X 24" 26 1/4"
|
|
|
+ Location (5) 1 1/8 (2) 7/8" Wiring Duct Receiving
|
|
|
+ (Optional) Knockouts Knockouts CL 73 3/8" Flange Typ.
|
|
|
+ Lift Lugs
|
|
|
+ LEFT VIEW RIGHT VIEW
|
|
|
+ FRONT VIEW
|
|
|
+
|
|
|
+ AIRFLOW CONFIGURATION UNIT MOUNTING & APPLICATION
|
|
|
+
|
|
|
+ MoAdvaeilalb:leLaEs8shXowINn Vin dimension drawing. Must be mounted as shown. RA/EA airstream can
|
|
|
+ Drawing Type: Unit Dimension be switched with OA/FA airstream unless certain
|
|
|
+ Version: MAY18 options are selected.
|
|
|
+
|
|
|
+ LE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HLE 8XRT Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+ROOFTOP UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+ Ventilation Type: Options:
|
|
|
+ Static plate, heat and humidity transfer Spring vibration isolators
|
|
|
+ Onboard variable frequency drives (VFDs) -
|
|
|
+ Typical Airflow Range: 2,000-8,800 CFM
|
|
|
+ one or both airstreams
|
|
|
+ AHRI 1060 Certified Core: Eight L125-G5 Shaft grounding ring on motors with VFDs
|
|
|
+ Fused disconnect
|
|
|
+ Standard Features: Integrated programmable controls -
|
|
|
+ TEFC Premium efficiency motors
|
|
|
+ Motor starters enhanced, premium
|
|
|
+ Non-fused disconnect Class 1 low leakage motorized isolation dampers -
|
|
|
+ 24 VAC transformer/relay package
|
|
|
+ Cross-core differential pressure ports OA, RA or both airstreams
|
|
|
+ Qty. 2, Factory mounted filter alarms -
|
|
|
+ Filters: Total qty. 16, MERV 8: 20" x 25" x 2"
|
|
|
+ both airstreams
|
|
|
+ Double wall construction
|
|
|
+ Exterior paint - white, custom colors
|
|
|
+
|
|
|
+ LE10XRT shown Unit Dimensions & Weight: Accessories:
|
|
|
+Download specification at: 111 1/4" L x 165 1/2" W x 71 1/4" H Filters - MERV 13, 2" or 4"; MERV 8, 4" (shipped loose)
|
|
|
+renewaire.com/specifications Modular (per module) 1,311-1,806 lbs., varies by option(s) Roof Curb - Standard 14"
|
|
|
+ Assembled (1-piece) 2,631-3,453 lbs., varies by option(s) Curb wind clip
|
|
|
+AIRFLOW PERFORMANCE Engineered combo curb for Carrier RTU
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Engineered combo curb for Trane RTU
|
|
|
+ Modular (2-modules) 100" L x 90" W x 78" H Digital time clock - wall mount (TC7D-W),
|
|
|
+
|
|
|
+ Module 1 - 1,986 lbs., Module 2 - 1,917 lbs. in exterior enclosure (TC7D-E)
|
|
|
+ Assembled (1-piece) 200" L x 90" W x 78" H - Carbon dioxide sensor/control -
|
|
|
+
|
|
|
+ 3,812 lbs. wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W), duct mount (IAQ-D)
|
|
|
+ Motor(s): Motion occupancy sensor/control -
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ with choice of adjustable sheaves for low, Smoke Detector - duct mount (SD-D)
|
|
|
+ medium or high blower speed (see table below) Electric duct heater - EK series (1–175 kW);
|
|
|
+
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+Airflow External Static Pressure (in.w.g.)
|
|
|
+ CFM
|
|
|
+ 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00
|
|
|
+ BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM
|
|
|
+ BHP RPM BHP RPM BHP RPM
|
|
|
+
|
|
|
+ 3 HP LOW SPEED 3 HP MED 3 HP HIGH SPEED
|
|
|
+ SPEED
|
|
|
+
|
|
|
+2000 1.3 640 1.3 730 1.4 810 1.6 8 90 1.9 960 2.4 1030 2.9 1100
|
|
|
+
|
|
|
+3000 1.5 700 1.6 780 1.9 860 2.2 930 2.7 1000 3.1 1060 3.7 1130 5 HP HIGH
|
|
|
+
|
|
|
+4000 1.6 680 1.9 760 2.2 840 2.6 910 3.0 980 3.5 1040 4.0 1100 4.6 1160 SPEED
|
|
|
+
|
|
|
+4500 1.8 710 2.1 800 2.5 870 3.0 940 3.5 1010 4.0 1060 4.5 1120 5.1 1170
|
|
|
+
|
|
|
+5000 1.7 660 2.1 750 2.5 83T0herm3.a0l Per9fo10rman3c.e5 Rati9n7g0s G5 42.015.21.0x3ls0x 4.5 1090 5.1 1184C0ores5.(6IOM1)190 7.5 HP
|
|
|
+5500 710 2.4 790 2.9 870 3.4 940 4.0 1000 4.5 1060 5.1 1110 5.6 1160 6.2 1210 HIGH
|
|
|
+6000 3 HP 2.0 750 2.9 840 3.4 910 4.0 970 4.5 1030 5.1 1090 5.7 1140 6.2 1190 6.8 1230 SPEED
|
|
|
+6250 LOW 2.4 780 3.1 860 3.7 930 4.2 990 4.8 1050 5.4 1100 6.0 1150 6.5 1200 7.1 1240
|
|
|
+ SPEED 2.6
|
|
|
+
|
|
|
+6500 2.8 800 3.4 880 4.0 950 4.5 1010 5.1 1060 5.7 1110 6.3 1160 6.8 1210 7.4 1250
|
|
|
+
|
|
|
+6750 5 HP 3.1 820 3.7 900 4.3 960 4.8 1020 5.4 1080 6.0 1130 6.6 1180 7.2 1220
|
|
|
+ LOW
|
|
|
+7000 SPEED 3.3 850 4.0 920 4.6 980 5.2 1040 5.8 1090 6.3 1140 6.9 1190 7.5 1230
|
|
|
+7250 3.6 870 4.3 940 4.9 1000 5.5 1060 6.1 1110 6.7 1160 7.2 1200
|
|
|
+
|
|
|
+7500 3.9 900 4.6 960 5.2 1020 5.8 1080 6.4 1120 7.0 1170
|
|
|
+
|
|
|
+7750 5 HP 4.3 920 4.9 980 5.6 1040 6.2 1090 6.8 1140 7.4 1180
|
|
|
+8000 MED 4.6 940 5.3 1000 5.9 1060 6.5 1110 7.1 1160
|
|
|
+8250 SPEED 5.0 970 5.7 1020 6.3 1080 6.9 1130 7.5 1170
|
|
|
+
|
|
|
+8500 5.4 990 6.0 1050 6.7 1100 7.3 1140
|
|
|
+
|
|
|
+8800 5.9 1020 6.5 1070 7.1 1120
|
|
|
+
|
|
|
+ 7.5 HP LOW SPEED 7.5 HP MED SPEED
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit. CORE PERFORMANCE
|
|
|
+ELECTRICAL DATA
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed
|
|
|
+ VFD Electrical Specifications
|
|
|
+ Airflow (CFM)
|
|
|
+ Max. Max.
|
|
|
+
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Overcurrent FLA Min. Cir. Overcurrent 2000 4000 6000 8000
|
|
|
+ per motor Amps Protection per motor Amps Protection 90%
|
|
|
+ Effectiveness (%)
|
|
|
+ Device Device
|
|
|
+
|
|
|
+3.0 208-230 60 Single 14.7-14 33.1 40 9.38-8.48 40.2 45 70%
|
|
|
+
|
|
|
+ 208-230 60 Three 9.38-8.48 21.1 25 9.38-8.48 23.2 25
|
|
|
+
|
|
|
+3.0 460 60 Three 4.24 9.5 15 4.24 10.5 15 50%
|
|
|
+
|
|
|
+ 575 60 Three 3.3 7.4 15 3.3 8.2 15
|
|
|
+
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 45 14.5-13.4 35.9 45 30%
|
|
|
+ At AHRI 1060 standard conditions.
|
|
|
+5.0 460 60 Three 6.7 15.1 20 6.7 16.6 20 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ 575 60 Three 5.3 11.9 15 5.3 13.1 15
|
|
|
+
|
|
|
+ 208-230 60 Three 21.0-19.0 47.3 60 21.0-19.0 52.0 60
|
|
|
+
|
|
|
+7.5 460 60 Three 9.5 21.4 25 9.5 23.5 25
|
|
|
+
|
|
|
+ 575 60 Three 7.6 17.1 20 7.6 18.8 20
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+16 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ LE8XRT (RTV/RTR) Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ CURB LE8X 69 3/4" Minimum RA Damper ABBREVIATIONS
|
|
|
+ Service Area Location EA: Exhaust Air to outside
|
|
|
+ (Optional) OA: Outside Air intake
|
|
|
+ 64 1/4" O.D. FA (RTV) Door Door RA: Room Air to be exhausted
|
|
|
+ (2) 16 1/8" X 16 3/8" Swing Swing FA: Fresh Air to inside
|
|
|
+ Openings RTV: Rooftop Vertical RA & FA
|
|
|
+ A A RTR: Rooftop Vertical RA Only
|
|
|
+ INSTALLATION ORIENTATION
|
|
|
+ 155 1/4" O.D. 9 1/2" 151 1/2" I.D. EA 18 1/4" OA Unit must be installed in orientation
|
|
|
+ 49" shown.
|
|
|
+ 20" 25" 36" E-Box 49 3/8" RA NOTE:
|
|
|
+ Minimum Door Door 24" X 48" 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ FA RA Service Area Swing Swing Opening DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 65 1/4" 52 1/8" OA 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 21 1/4" 3" 38 1/4" 78 1/2" CURB CROSS-SECTION A-A (TYP.)
|
|
|
+ 60 1/2" I.D. Minimum
|
|
|
+ Blower Service 1 1/2" X 1/4" 1 7/8"
|
|
|
+ TOP VIEW Area Typ. Neoprene Gasket
|
|
|
+
|
|
|
+ 111" Minimum 3/4" X 3 1/2" 14"
|
|
|
+ Service Area Wooden Nailer
|
|
|
+
|
|
|
+ 3"
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 17 13 3/8" X 15 1/2" TOP VIEW SECTION A-A
|
|
|
+ Electrical
|
|
|
+ EA Outlet Connection E-Box 111 1/4" Overall 165 3/8" Overall
|
|
|
+ Cover 69 1/8" Case 162 5/8" Case
|
|
|
+ Disconnect 22 1/2" 19 3/4"
|
|
|
+ 64 5/8" Switch
|
|
|
+
|
|
|
+ 71 1/8" Overall 8 7/8" FA RTR Pressure Ports
|
|
|
+ 65 5/8" ONLY (4) Typ.
|
|
|
+ Case FA
|
|
|
+
|
|
|
+ 38 5/8" 53 1/2"
|
|
|
+
|
|
|
+ 25 1/4" 27 3/4" RA 2" Duct 73 3/8" 2" Typ. OA Inlets,
|
|
|
+ RAFlange Typ.Lifting Lugs OA Damper
|
|
|
+ CL 11 3/8" CL 5 1/4"
|
|
|
+ FA (RTR) (5) 7/8" (2) 7/8" FA Locations
|
|
|
+ Knockouts (Optional)
|
|
|
+ 48" X 24" Knockouts RTV RA
|
|
|
+ HERT except 6x 8x, LERT ONLY RIGHT VIEW
|
|
|
+ Duct Receiving
|
|
|
+ FRONT VIEW HERT except 6x 8x, LERT UNIT MOUNTING & APPLICATION
|
|
|
+ Flange LEFT VIEW Must be mounted as shown. Airstreams can not
|
|
|
+ be switched.
|
|
|
+ ModAeIRlF: LLOE8WXCROTNVF/IRGTURRATION RTV RTR
|
|
|
+ DrawAvaiinlabgle aTsysphoewn:: Unit Dimension
|
|
|
+ Version: MAY18 EA OA EA OA
|
|
|
+
|
|
|
+ FA
|
|
|
+
|
|
|
+ LE-SERIES
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+18 RENEWAIRE.COM 1.800.627.4499
|
|
|
+LE8XRT (RTH/RTF) Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ 69 3/4" Minimum ABBREVIATIONS
|
|
|
+ Service Area EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ CURB LE8X RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ 64 1/4" O.D. FA (RTF) Door Door RTF: Rooftop Vertical FA Only
|
|
|
+ (2) 16 1/8" X 16 3/8" Swing Swing RTH: Rooftop Horizontal RA & FA
|
|
|
+ Openings INSTALLATION ORIENTATION
|
|
|
+ Unit must be installed in orientation
|
|
|
+ A A shown.
|
|
|
+ NOTE:
|
|
|
+ EA OA 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ 155 1/4" O.D. 9 1/2" 151 1/2" I.D. 36" E-Box NEAREST EIGHTH OF AN INCH.
|
|
|
+ 49" Minimum 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ 20" 25" Service Area 18 1/4" TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ FA RA
|
|
|
+
|
|
|
+ 65 1/4" OA
|
|
|
+
|
|
|
+ FA CURB CROSS-SECTION A-A (TYP.)
|
|
|
+
|
|
|
+ 21 1/4" 3" 38 1/4" Door Door 78 1/2" 1 1/2" X 1/4" 1 7/8"
|
|
|
+ 60 1/2" I.D. Swing Swing Minimum Neoprene Gasket
|
|
|
+ Blower Service
|
|
|
+ TOP VIEW Area Typ. 3/4" X 3 1/2"
|
|
|
+ Wooden Nailer
|
|
|
+ 14"
|
|
|
+ 3"
|
|
|
+
|
|
|
+ 13 3/8" X 15 1/2" 111" Minimum SECTION A-A
|
|
|
+ Electrical Service Area
|
|
|
+ Connection
|
|
|
+ Cover TOP VIEW
|
|
|
+
|
|
|
+EA Outlet 64 5/8" E-Box 111 1/4" Overall RA 165 3/8" Overall
|
|
|
+ 69 1/8" Case Damper 162 5/8" Case
|
|
|
+ Disconnect 22 1/2" 19 3/4" Location
|
|
|
+ Switch (Optional)
|
|
|
+71 1/8" Overall Pressure Ports
|
|
|
+ 65 5/8" 8 7/8" (4) Typ. 8 7/8"
|
|
|
+ Case 53 1/2"
|
|
|
+ FA RTH RA
|
|
|
+ 38 5/8" ONLY
|
|
|
+
|
|
|
+ 25 1/4" CL 11 3/8" 27 3/4" 2" Duct 73 3/8" 2" Typ. 27 3/8" OA Inlets,
|
|
|
+ (5) 7/8" Flange Typ. Lifting Lugs OA Damper
|
|
|
+ Knockouts CL 5 1/4" 5" Damper RIGHT VIEW
|
|
|
+FA (RTH) (2) 7/8" FA Frames Typ. RA Locations
|
|
|
+48" X 24" Knockouts 48" X 24" (Optional)
|
|
|
+ RTF Duct Receiving
|
|
|
+ HERT except 6x 8x, LERT ONLY Flange
|
|
|
+
|
|
|
+Duct Receiving LEFT VIEW FRONT VIEW HERTexcept 6x 8x, LERT
|
|
|
+Flange
|
|
|
+
|
|
|
+ModAeIRl:FLLOE8WXCROTNHF/IRGTUFRATION RTH RTF UNIT MOUNTING & APPLICATION
|
|
|
+DrawAvaiinlabgle aTsysphoewn:: Unit Dimension
|
|
|
+ EA OA EA OA Must be mounted as shown. Airstreams can not
|
|
|
+ FA RA be switched.
|
|
|
+Version: MAY18 RA
|
|
|
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 19
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HLE 10XINH Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+ LE10XINV shown Ventilation Type: Options:
|
|
|
+Download specification at: Static plate, heat and humidity transfer Spring vibration isolators
|
|
|
+renewaire.com/specifications Onboard variable frequency drives (VFDs) -
|
|
|
+ Typical Airflow Range: 2,500-11,000 CFM
|
|
|
+AIRFLOW PERFORMANCE one or both airstreams
|
|
|
+ AHRI 1060 Certified Core: Ten L125-G5 Shaft grounding ring on motors with VFDs
|
|
|
+ Fused disconnect
|
|
|
+ Standard Features: Integrated programmable controls -
|
|
|
+ TEFC Premium efficiency motors
|
|
|
+ Motor starters enhanced, premium
|
|
|
+ Non-fused disconnect Class 1 low leakage motorized isolation dampers -
|
|
|
+ 24 VAC transformer/relay package
|
|
|
+ Rubber vibration isolators OA, RA or both
|
|
|
+ Cross-core differential pressure ports Qty. 2, Factory mounted filter alarms -
|
|
|
+
|
|
|
+ Filters: Total qty. 20, MERV 8: 20" x 25" x 2" both airstreams
|
|
|
+ Double wall construction
|
|
|
+ Unit Dimensions & Weight: Exterior paint - white, custom colors
|
|
|
+ 80 1/2" L x 205 1/2" W x 71 1/4" H
|
|
|
+ Modular (per module) 1,423-1,912 lbs., varies by option(s) Accessories:
|
|
|
+ Assembled (1-piece) 2,858-3,799 lbs., varies by option(s) Filters - MERV 13, 2" or 4"; MERV 8, 4" (shipped loose)
|
|
|
+ Digital time clock - wall mount (TC7D-W),
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet):
|
|
|
+ Modular (2-modules) 120" L x 90" W x 78" H in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ Module 1 - 2,132 lbs., Module 2 - 2,107 lbs.
|
|
|
+ Assembled (1-piece) 240" L x 90" W x 78" H - 4,239 lbs. wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W), duct mount (IAQ-D)
|
|
|
+ Motor(s): Motion occupancy sensor/control -
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages
|
|
|
+ ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ with choice of adjustable sheaves for low, Smoke Detector - duct mount (SD-D)
|
|
|
+ medium or high blower speed. (see table below) Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+Airflow External Static Pressure (in.w.g.)
|
|
|
+ CFM
|
|
|
+ 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00
|
|
|
+ BHP RPM BHP RPM BHP RPM
|
|
|
+ BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM
|
|
|
+
|
|
|
+ 3 HP LOW SPEED 3 HP MED SPEED 3 HP HIGH SPEED
|
|
|
+
|
|
|
+2500 1.1 710 1.3 790 1.6 870 1.8 930 2.1 1000 2.4 1050
|
|
|
+
|
|
|
+3000 1.0 640 1.3 730 1.5 810 1.8 880 2.0 950 2.3 1010 2.6 1070
|
|
|
+
|
|
|
+3500 1.2 660 1.4 750 1.7 830 2.0 900 2.3 960 2.6 1020 2.9 1080
|
|
|
+
|
|
|
+4000 1.4 680 1.6 770 1.9 840 2.2 910 2.5 980 2.9 1040 3.2 1100
|
|
|
+
|
|
|
+4500 1.6 710 1.9 790 2.2 860 2.5 930 2.8 990 3.2 1050 3.5 1110 5 HP
|
|
|
+
|
|
|
+5000 1.6 670 1.9 740 2.1 810 2.5 880 2.8 940 3.1 1000 3.5 1060 3.9 1120 HIGH
|
|
|
+
|
|
|
+5500 1.6 640 1.9 710 2.2 770 2.5 840 2.8 900 3.1 960 3.5 1020 3.8 1080 4.2 1130 SPEED
|
|
|
+
|
|
|
+6000 3 HP 2.0 690 2.2 750 2.5 810 2.8 870 3.1 920 3.5 980 3.9 1040 4.2 1090 4.6 1150
|
|
|
+
|
|
|
+ LOW 7.5 HP
|
|
|
+ SPEED
|
|
|
+6500 2.4 740 2.6 790 2.9 850 3.2 900 3.6 950 3.9 1000 4.3 1060 4.7 1110 5.1 1160 MED
|
|
|
+
|
|
|
+ Thermal Performance Ratings G5 2015.2.xlsx 10 Cores (IOM) SPEED
|
|
|
+
|
|
|
+7000 2.8 790 3.1 830 3.4 880 3.7 930 4.0 980 4.4 1030 4.8 1080 5.2 1130 5.6 1170
|
|
|
+
|
|
|
+7500 5 HP 3.3 830 3.6 880 3.9 920 4.2 970 4.6 1010 4.9 1050 5.3 1100 5.7 1140 6.1 1190
|
|
|
+
|
|
|
+8000 LOW 3.9 880 4.2 920 4.5 960 4.8 1000 5.1 1040 5.5 1080 5.9 1120 6.3 1160 6.7 1200 7.5 HP
|
|
|
+ SPEED HIGH
|
|
|
+
|
|
|
+ 5 HP SPEED
|
|
|
+
|
|
|
+8500 MED 4.5 930 4.8 960 5.1 1000 5.4 1030 5.8 1070 6.1 1100 6.5 1140 6.9 1180 7.3 1210
|
|
|
+
|
|
|
+ SPEED
|
|
|
+
|
|
|
+9000 7.5 HP 5.2 970 5.5 1000 5.8 1030 6.1 1060 6.4 1100 6.8 1130 7.1 1160 7.5 1190 7.9 1220
|
|
|
+
|
|
|
+9500 LOW 5.9 1010 6.2 1040 6.5 1060 6.8 1090 7.1 1120 7.5 1150 7.8 1180 8.2 1210 8.5 1230 10 HP
|
|
|
+ 8.5 1190 8.9 1220 9.2 1240 HIGH
|
|
|
+10000 SPEED 6.7 1040 7.0 1070 7.3 1090 7.6 1120 7.9 1140 8.2 1170
|
|
|
+
|
|
|
+ 7.5 HP 9.3 1210 9.6 1230 10.0 1250 SPEED
|
|
|
+
|
|
|
+10500 MED 7.5 1080 7.8 1100 8.1 1120 8.4 1140 8.7 1160 9.0 1190
|
|
|
+
|
|
|
+ SPEED
|
|
|
+
|
|
|
+11000 8.4 1100 8.6 1120 8.9 1140 9.2 1160 9.5 1180 9.8 1200
|
|
|
+
|
|
|
+ 10 HP MED SPEED 10 HP HIGH SPEED
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+ 4000 6000 8000
|
|
|
+ Max. Max.
|
|
|
+
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Overcurrent FLA Min. Cir. Overcurrent 2000 10000 12000
|
|
|
+ per motor Amps Protection per motor Amps Protection 90%
|
|
|
+ Effectiveness (%)
|
|
|
+ Device Device
|
|
|
+
|
|
|
+3.0 208-230 60 Single 14.7-14 33.1 40 9.38-8.48 40.2 45 70%
|
|
|
+
|
|
|
+ 208-230 60 Three 9.38-8.48 21.1 25 9.38-8.48 23.2 25 50%
|
|
|
+
|
|
|
+3.0 460 60 Three 4.24 9.5 15 4.24 10.5 15 30%
|
|
|
+ At AHRI 1060 standard conditions.
|
|
|
+ 575 60 Three 3.3 7.4 15 3.3 8.2 15 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 45 14.5-13.4 35.9 45 Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+5.0 460 60 Three 6.7 15.1 20 6.7 16.6 20
|
|
|
+
|
|
|
+ 575 60 Three 5.3 11.9 15 5.3 13.1 15
|
|
|
+
|
|
|
+ 208-230 60 Three 21.0-19.0 47.3 60 21.0-19.0 52.0 60
|
|
|
+
|
|
|
+7.5 460 60 Three 9.5 21.4 25 9.5 23.5 25
|
|
|
+
|
|
|
+ 575 60 Three 7.6 17.1 20 7.6 18.8 20
|
|
|
+
|
|
|
+ 208-230 60 Three 27.0-24.4 60.8 80 27.0-24.4 66.8 80
|
|
|
+
|
|
|
+10.0 460 60 Three 12.2 27.5 35 12.2 30.2 35
|
|
|
+
|
|
|
+ 575 60 Three 9.76 22.0 30 9.76 24.2 30
|
|
|
+
|
|
|
+20 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ LE10XINH Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ 69 3/4" ABBREVIATIONS
|
|
|
+ Minimum EA: Exhaust Air to outside
|
|
|
+ Service Area OA: Outside Air intake
|
|
|
+ RA: Room Air to be exhausted
|
|
|
+ Door Door FA: Fresh Air to inside
|
|
|
+ Swing Swing INSTALLATION ORIENTATION
|
|
|
+ Unit must be installed in orientation
|
|
|
+ EA OA shown.
|
|
|
+ NOTE
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ 3. MIN. DUCT CLEARANCE FROM
|
|
|
+ DAMPER BLADES WHEN FULLY
|
|
|
+ OPENED TO BE 2". SMACNA RULES
|
|
|
+ APPLY.
|
|
|
+
|
|
|
+ FA RA
|
|
|
+
|
|
|
+ 36" E-Box
|
|
|
+ Minimum
|
|
|
+ Service Area
|
|
|
+
|
|
|
+ Door Door 79 7/8"
|
|
|
+ Swing Swing Minimum
|
|
|
+
|
|
|
+ 13 3/8" X 15 1/2" Blower RA Inlet
|
|
|
+ Service 48" X 24"
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 21 Electrical 111" Minimum Area Typ. Duct Receiving OA Inlet
|
|
|
+ Service Area Flange 48" X 24"
|
|
|
+ 48" X 24" Connection E-Box Duct Receiving
|
|
|
+ Disconnect TOP VIEW 205 3/8" Overall Flange
|
|
|
+ Duct Receiving Cover 202 5/8" Case
|
|
|
+ Switch 80 3/8"
|
|
|
+ Flange Typ. Overall
|
|
|
+ 47 1/4" 2"
|
|
|
+ 84 5/8" 53 1/2" Pressure
|
|
|
+ EA Ports (4) Typ.
|
|
|
+ 71 1/8" Overall
|
|
|
+ 69 5/8" Case OA
|
|
|
+
|
|
|
+ 47 1/4" FA RA 41 1/2"
|
|
|
+
|
|
|
+ CL 11 3/8"41 1/8"29 5/8" 69 1/8" Case 2" 47 1/4" RA Damper 47 1/4"
|
|
|
+ (5) 1 1/8" 4" 73 3/8" Typ. Location
|
|
|
+ Knockouts CL 5 1/4" CL 2 1/4" Lift Lugs 8 3/4" (Optional) OA Damper
|
|
|
+ (2) 7/8" Wiring 5" Damper Typ. Location
|
|
|
+ LEFT VIEW Knockouts FRONT VIEW Frames Typ. RIGHT VIEW (Optional)
|
|
|
+ AMIRoFdLOeW l: LCE1O0NXFINIGHURATION
|
|
|
+ ADvairlaabwle ains sghowTyn pin edim: eUnsnioint dDraiwminge. nsion UNIT MOUNTING & APPLICATION
|
|
|
+ Version: MAY18
|
|
|
+ Must be mounted as shown. RA/EA airstream can
|
|
|
+ be switched with OA/FA airstream unless certain
|
|
|
+ options are selected.
|
|
|
+
|
|
|
+ LE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HLE 10XINV Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+INDOOR UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Spring vibration isolators
|
|
|
+ Onboard variable frequency drives (VFDs) -
|
|
|
+AIRFLOW PERFORMANCE Typical Airflow Range: 2,500-11,000 CFM
|
|
|
+ one or both airstreams
|
|
|
+ AHRI 1060 Certified Core: Ten L125-G5 Shaft grounding ring on motors with VFDs
|
|
|
+ Fused disconnect
|
|
|
+ Standard Features: Integrated programmable controls -
|
|
|
+ TEFC Premium efficiency motors
|
|
|
+ Motor starters enhanced, premium
|
|
|
+ Non-fused disconnect Class 1 low leakage motorized isolation dampers -
|
|
|
+ 24 VAC transformer/relay package
|
|
|
+ Rubber vibration isolators OA, RA or both
|
|
|
+ Cross-core differential pressure ports Qty. 2, Factory mounted filter alarms -
|
|
|
+
|
|
|
+ Filters: Total qty. 20, MERV 8: 20" x 25" x 2" both airstreams
|
|
|
+ Double wall construction
|
|
|
+ Unit Dimensions & Weight: Exterior paint - white, custom colors
|
|
|
+ 81 1/2" L x 205 1/2" W x 71 1/4" H
|
|
|
+ Modular (per module) 1,127-2,222 lbs., varies by option(s) Accessories:
|
|
|
+ Assembled (1-piece) 2,858-3,788 lbs., varies by option(s) Filters - MERV 13, 2" or 4"; MERV 8, 4" (shipped loose)
|
|
|
+ Digital time clock - wall mount (TC7D-W),
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet):
|
|
|
+ Modular (2-modules) 120" L x 90" W x 78" H in exterior enclosure (TC7D-E)
|
|
|
+ Carbon dioxide sensor/control -
|
|
|
+ Module 1 - 2,442 lbs., Module 2 - 1,792 lbs.
|
|
|
+ Assembled (1-piece) 240" L x 90" W x 78" H - wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ IAQ sensor - wall mount (IAQ-W), duct mount (IAQ-D)
|
|
|
+ 4,228 lbs. Motion occupancy sensor/control -
|
|
|
+
|
|
|
+ Motor(s): Qty. 2, Belt drive blower/standard motor ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ packages with choice of adjustable sheaves for low, Smoke Detector - duct mount (SD-D)
|
|
|
+ medium or high blower speed. (see table below) Electric duct heater - EK series (1–175 kW)
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+Airflow External Static Pressure (in.w.g.)
|
|
|
+ CFM
|
|
|
+ 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00
|
|
|
+ BHP RPM BHP RPM BHP RPM
|
|
|
+ BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM
|
|
|
+ 1.6 640 1.6 670 1.0 640
|
|
|
+ 2.0 690 1.9 710 1.2 660 3 HP LOW SPEED 3 HP MED SPEED 3 HP HIGH SPEED
|
|
|
+ 2.4 740 2.2 750 1.4 680
|
|
|
+2500 2.8 790 1.6 710 1.1 710 1.3 790 1.6 870 1.8 930 2.1 1000 2.4 1050
|
|
|
+3000 3.3 830 1.9 740
|
|
|
+3500 3.9 880 2.2 770 1.3 730 1.5 810 1.8 880 2.0 950 2.3 1010 2.6 1070
|
|
|
+4000 2.5 810 1.4 750 1.7 830 2.3 960 2.6 1020 2.9 1080
|
|
|
+4500 4.5 930 1.6 770 1.9 840 2.0 900 2.5 980 2.9 1040 3.2 1100
|
|
|
+5000 5.2 970
|
|
|
+5500 5.9 1010 2.2 910
|
|
|
+6000 6.7 1040
|
|
|
+ 7.5 1080 1.9 790 2.2 860 2.5 930 2.8 990 3.2 1050 3.5 1110 5 HP
|
|
|
+6500 8.4 1100 HIGH
|
|
|
+ 2.1 810 2.5 880 2.8 940 3.1 1000 3.5 1060 3.9 1120 SPEED
|
|
|
+7000 2.5 840 2.8 900 3.5 1020 3.8 1080 4.2 1130
|
|
|
+7500 3.1 960 7.5 HP
|
|
|
+8000 MED
|
|
|
+ 3 HP 2.8 870 3.1 920 3.5 980 3.9 1040 4.2 1090 4.6 1150 SPEED
|
|
|
+8500 LOW
|
|
|
+ SPEED 2.6 790 2.9 850 3.2 900 3.6 950 3.9 1000 4.3 1060 4.7 1110 5.1 1160 7.5 HP
|
|
|
+9000 Thermal Performance Ratings G5 2015.2.xlsx 10 Cores (IOM) HIGH
|
|
|
+9500 5 HP SPEED
|
|
|
+10000 LOW 3.1 830 3.4 880 3.7 930 4.0 980 4.4 1030 4.8 1080 5.2 1130 5.6 1170
|
|
|
+ SPEED 3.6 880 3.9 920 4.2 970 4.6 1010 4.9 1050 5.3 1100 5.7 1140 6.1 1190
|
|
|
+10500 5 HP
|
|
|
+ MED 4.2 920 4.5 960 4.8 1000 5.1 1040 5.5 1080 5.9 1120 6.3 1160 6.7 1200
|
|
|
+11000 SPEED
|
|
|
+ 7.5 HP 4.8 960 5.1 1000 5.4 1030 5.8 1070 6.1 1100 6.5 1140 6.9 1180 7.3 1210
|
|
|
+ LOW
|
|
|
+ SPEED 5.5 1000 5.8 1030 6.1 1060 6.4 1100 6.8 1130 7.1 1160 7.5 1190 7.9 1220
|
|
|
+ 7.5 HP 6.2 1040 6.5 1060 6.8 1090 7.1 1120 7.5 1150
|
|
|
+ MED 7.0 1070 7.3 1090 7.6 1120 7.9 1140 8.2 1170 7.8 1180 8.2 1210 8.5 1230 10 HP
|
|
|
+ SPEED 8.5 1190 8.9 1220 9.2 1240 HIGH
|
|
|
+
|
|
|
+ 7.8 1100 8.1 1120 8.4 1140 8.7 1160 9.0 1190 9.3 1210 9.6 1230 10.0 1250 SPEED
|
|
|
+
|
|
|
+ 8.6 1120 8.9 1140 9.2 1160 9.5 1180 9.8 1200
|
|
|
+
|
|
|
+ 10 HP MED SPEED 10 HP HIGH SPEED
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit. CORE PERFORMANCE
|
|
|
+ELECTRICAL DATA
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+ 4000 6000 8000
|
|
|
+ Max. Max.
|
|
|
+
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Overcurrent FLA Min. Cir. Overcurrent 2000 10000 12000
|
|
|
+ per motor Amps Protection per motor Amps Protection 90%
|
|
|
+ Effectiveness (%)
|
|
|
+ Device Device
|
|
|
+
|
|
|
+3.0 208-230 60 Single 14.7-14 33.1 40 9.38-8.48 40.2 45 70%
|
|
|
+
|
|
|
+ 208-230 60 Three 9.38-8.48 21.1 25 9.38-8.48 23.2 25 50%
|
|
|
+
|
|
|
+3.0 460 60 Three 4.24 9.5 15 4.24 10.5 15 30%
|
|
|
+ At AHRI 1060 standard conditions.
|
|
|
+ 575 60 Three 3.3 7.4 15 3.3 8.2 15 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 45 14.5-13.4 35.9 45 Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+5.0 460 60 Three 6.7 15.1 20 6.7 16.6 20
|
|
|
+
|
|
|
+ 575 60 Three 5.3 11.9 15 5.3 13.1 15
|
|
|
+
|
|
|
+ 208-230 60 Three 21.0-19.0 47.3 60 21.0-19.0 52.0 60
|
|
|
+
|
|
|
+7.5 460 60 Three 9.5 21.4 25 9.5 23.5 25
|
|
|
+
|
|
|
+ 575 60 Three 7.6 17.1 20 7.6 18.8 20
|
|
|
+
|
|
|
+ 208-230 60 Three 27.0-24.4 60.8 80 27.0-24.4 66.8 80
|
|
|
+
|
|
|
+10.0 460 60 Three 12.2 27.5 35 12.2 30.2 35
|
|
|
+
|
|
|
+ 575 60 Three 9.76 22.0 30 9.76 24.2 30
|
|
|
+
|
|
|
+22 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ LE10XINV Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ 69 3/4" ABBREVIATIONS
|
|
|
+ Minimum EA: Exhaust Air to outside
|
|
|
+ Service Area OA: Outside Air intake
|
|
|
+ RA: Room Air to be exhausted
|
|
|
+ Door Door FA: Fresh Air to inside
|
|
|
+ Swing Swing INSTALLATION ORIENTATION
|
|
|
+ Unit must be installed in orientation
|
|
|
+ 34" Minimum shown.
|
|
|
+ Service Area NOTE
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ RA OA DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ FA EA 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ TO CHANGE WITHOUT NOTICE.
|
|
|
+ 36" E-Box 3.DUCT CLEARANCE FROM
|
|
|
+ Minimum DAMPER BLADE WHEN FULLY
|
|
|
+ Service Area OPENED TO BE 2". SMACNA RULES
|
|
|
+ APPLY.
|
|
|
+
|
|
|
+ Door Door 79 7/8"
|
|
|
+ Swing Swing Minimum
|
|
|
+
|
|
|
+ 13 3/8" X 15 1/2" 111" Minimum Blower
|
|
|
+ Electrical Service Area Service Area
|
|
|
+
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 23 RA Damper Connection 5" Damper TOP VIEW OA Damper OA Inlet
|
|
|
+ Location Cover Frames Typ. Location 48" X 24"
|
|
|
+ RA Inlet (Optional) 81 3/8" (Optional) Duct Receiving
|
|
|
+ 48" X 24" E-Box Overall Flange
|
|
|
+ Duct Receiving Disconnect 205 3/8" Overall
|
|
|
+ Flange 53 1/2" Pressure 202 5/8" Case
|
|
|
+ Switch Ports (4) Typ.
|
|
|
+ 47 1/4"
|
|
|
+
|
|
|
+ 84 5/8"
|
|
|
+
|
|
|
+ 71 1/8" Overall RA OA
|
|
|
+ 69 5/8" Case
|
|
|
+ 41 5/8" 8 7/8" 41 5/8"
|
|
|
+ 8 7/8"
|
|
|
+ FA EA
|
|
|
+
|
|
|
+ 47 3/8" CL 11 3/8" 29 5/8" 2" Typ. 69 1/8" Case 47 1/4" 47 3/8"
|
|
|
+ (5) 1 1/8" CL 2 1/4" 48" X 24"
|
|
|
+ Knockouts Wiring 4" 73 3/8" 2" Duct Duct Receiving
|
|
|
+ Lift Lugs Flange Typ. Flange Typ.
|
|
|
+ CL 5 1/4"
|
|
|
+ LEFT VIEW (2) 7/8" FRONT VIEW RIGHT VIEW
|
|
|
+ MAIoRdFLeOl:WLEC1O0XNIFNIGVURATION Knockouts
|
|
|
+ DAvraailawbleinasgshToywnpined:imUennsiitonDdriamwiengn. sion UNIT MOUNTING & APPLICATION
|
|
|
+ Version: MAY18 Must be mounted as shown. RA/EA airstream can
|
|
|
+ be switched with OA/FA airstream unless certain
|
|
|
+ options are selected.
|
|
|
+
|
|
|
+ LE-SERIES
|
|
|
+SPECIFICATIONS & DIMENSIONS
|
|
|
+
|
|
|
+HLE 10XRT Energy Recovery Ventilator
|
|
|
+ Standard
|
|
|
+
|
|
|
+ROOFTOP UNIT SPECIFICATIONS
|
|
|
+
|
|
|
+Download specification at: Ventilation Type: Options:
|
|
|
+renewaire.com/specifications Static plate, heat and humidity transfer Spring vibration isolators
|
|
|
+ Onboard variable frequency drives (VFDs) -
|
|
|
+AIRFLOW PERFORMANCE Typical Airflow Range: 2,500-11,000 CFM
|
|
|
+ one or both airstreams
|
|
|
+ AHRI 1060 Certified Core: Ten L125-G5 Shaft grounding ring on motors with VFDs
|
|
|
+ Fused disconnect
|
|
|
+ Standard Features: Integrated programmable controls -
|
|
|
+ TEFC Premium efficiency motors
|
|
|
+ Motor starters enhanced, premium
|
|
|
+ Non-fused disconnect Class 1 low leakage motorized isolation dampers -
|
|
|
+ 24 VAC transformer/relay package
|
|
|
+ Rubber vibration isolators OA, RA or both
|
|
|
+ Cross-core differential pressure ports Qty. 2, Factory mounted filter alarms -
|
|
|
+
|
|
|
+ Filters: both airstreams
|
|
|
+ Total qty. 20, MERV 8: 20" x 25" x 2" Double wall construction
|
|
|
+ Exterior paint - white, custom colors
|
|
|
+ Unit Dimensions & Weight:
|
|
|
+ 111 1/4" L x 205 1/2" W x 71 1/4" H Accessories:
|
|
|
+ Modular (per module) 1,493-2,057 lbs., varies by option(s) Filters - MERV 13, 2" or 4"; MERV 8, 4" (shipped loose)
|
|
|
+ Assembled (1-piece) 3,032-3,993 lbs., varies by option(s) Roof curb - standard 14"
|
|
|
+ Curb wind clip
|
|
|
+ Max. Shipping Dimensions & Weight (on pallet): Digital time clock - wall mount (TC7D-W),
|
|
|
+ Modular (2-modules) 120" L x 90" W x 78" H
|
|
|
+ in exterior enclosure (TC7D-E)
|
|
|
+ Module 1 - 2,277 lbs., Module 2 - 2,245 lbs. Carbon dioxide sensor/control -
|
|
|
+ Assembled (1-piece) 240" L x 90" W x 78" H -
|
|
|
+ wall mount (CO2-W), duct mount (CO2-D)
|
|
|
+ 4,433 lbs. IAQ sensor - wall mount (IAQ-W), duct mount (IAQ-D)
|
|
|
+ Motion occupancy sensor/control -
|
|
|
+ Motor(s):
|
|
|
+ Qty. 2, Belt drive blower/standard motor packages ceiling mount (MC-C), wall mount (MC-W)
|
|
|
+ Smoke Detector - duct mount (SD-D)
|
|
|
+ with choice of adjustable sheaves for low, Electric duct heater - EK series (1–175 kW);
|
|
|
+ medium or high blower speed. (see table below)
|
|
|
+ designed for indoor ductwork installation only
|
|
|
+ Indirect gas-fired duct furnace - GH series
|
|
|
+
|
|
|
+ (50-400 MBH), installed downstream of any fans
|
|
|
+
|
|
|
+Airflow External Static Pressure (in.w.g.)
|
|
|
+ CFM
|
|
|
+ 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00
|
|
|
+ 2500 BHP RPM BHP RPM
|
|
|
+ 3000 BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM
|
|
|
+ 3500 1.4 650
|
|
|
+ 4000 1.7 680 3 HP LOW SPEED 3 HP MED SPEED 3 HP HIGH SPEED
|
|
|
+ 4500 2.0 720
|
|
|
+ 5000 2.4 760 1.0 640 1.2 740 1.5 820 1.7 880 2.0 950 2.3 1000 2.6 1060
|
|
|
+ 5500 2.8 800
|
|
|
+ 6000 3.3 850 1.1 660 1.4 760 1.7 830 2.0 900 2.3 960 2.6 1020 2.9 1070
|
|
|
+ 6500 3.9 890
|
|
|
+ 7000 4.5 930 1.3 690 1.6 770 1.9 850 2.2 920 2.5 980 2.9 1040 3.2 1090
|
|
|
+ 7500 5.2 970
|
|
|
+ 8000 5.9 1010 1.5 710 1.8 790 2.1 870 2.5 930 2.8 1000 3.2 1060 3.6 1110 5 HP HIGH
|
|
|
+ 6.6 1050 3.2 1020 3.6 1070 3.9 1130 SPEED
|
|
|
+ 8500 1.7 740 2.1 810 2.4 890 2.8 950 3.5 1030 3.9 1090 4.4 1150
|
|
|
+
|
|
|
+ 9000 2.0 760 2.4 840 2.7 910 3.1 970
|
|
|
+
|
|
|
+ 9500 1.7 650 2.4 T8h0e0rmal2P.7erfor8m70ance3R.1ating9s3G05 2031.55.2.x9ls9x0 3.9 1050 4.4 1101C10ores4(.I8OM)1170
|
|
|
+ 2.8 830 3.1 890 3.5 960 4.0 1020 4.4 1080 4.8 1130 5.3 1190
|
|
|
+ 3 HP LOW 2.1 690
|
|
|
+
|
|
|
+ SPEED 2.5 740 3.2 870 3.6 930 4.0 980 4.4 1040 4.9 1100 5.3 1160 5.8 1210 7.5 HP
|
|
|
+
|
|
|
+ 3.0 790 3.7 900 4.1 960 4.5 1010 5.0 1070 5.4 1120 5.9 1180 6.4 1230 HIGH
|
|
|
+
|
|
|
+ 5 HP LOW 3.5 840 4.3 940 4.7 990 5.1 1040 5.5 1100 6.0 1150 6.4 1200 6.9 1250 SPEED
|
|
|
+
|
|
|
+ SPEED 4.1 880 4.9 980 5.3 1030 5.7 1070 6.1 1120 6.6 1170 7.0 1220 7.5 1270
|
|
|
+
|
|
|
+ 5 HP MED 4.8 930 5.5 1010 5.9 1060 6.3 1100 6.8 1150 7.2 1200 7.7 1240 8.1 1290
|
|
|
+ SPEED
|
|
|
+
|
|
|
+ 7.5 HP LOW 5.5 970 6.2 1050 6.6 1090 7.0 1130 7.4 1170 7.8 1220 8.3 1260 8.7 1300 10 HP
|
|
|
+
|
|
|
+ SPEED 6.2 1010 6.9 1080 7.3 1120 7.7 1160 8.1 1200 8.5 1240 8.9 1280 9.3 1310 HIGH
|
|
|
+ SPEED
|
|
|
+
|
|
|
+10000 7.5 HP MED 7.0 1050 7.3 1080 7.7 1110 8.0 1150 8.4 1180 8.7 1220 9.1 1250 9.5 1290 9.9 1320
|
|
|
+ SPEED
|
|
|
+
|
|
|
+10500 7.8 1080 8.1 1110 8.4 1140 8.7 1170 9.1 1200 9.4 1230 9.7 1260
|
|
|
+
|
|
|
+11000 8.6 1110 8.9 1140 9.2 1160 9.4 1190 9.7 1220
|
|
|
+
|
|
|
+ 10 HP MED SPEED 10 HP HIGH SPEED
|
|
|
+
|
|
|
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
|
|
|
+
|
|
|
+ELECTRICAL DATA CORE PERFORMANCE
|
|
|
+
|
|
|
+ Standard Electrical Specifications Optional Factory Installed Airflow (CFM)
|
|
|
+ VFD Electrical Specifications
|
|
|
+ 4000 6000 8000
|
|
|
+ Max. Max. 2000 10000 12000
|
|
|
+ 90%
|
|
|
+HP Volts HZ Phase FLA Min. Cir. Overcurrent FLA per Min. Cir. Overcurrent Effectiveness (%)
|
|
|
+ per motor Amps Protection motor Amps Protection
|
|
|
+
|
|
|
+ Device Device
|
|
|
+
|
|
|
+3.0 208-230 60 Single 14.7-14 33.1 40 9.38-8.48 40.2 45 70%
|
|
|
+
|
|
|
+ 208-230 60 Three 9.38-8.48 21.1 25 9.38-8.48 23.2 25 50%
|
|
|
+
|
|
|
+3.0 460 60 Three 4.24 9.5 15 4.24 10.5 15 30%
|
|
|
+ At AHRI 1060 standard conditions.
|
|
|
+ 575 60 Three 3.3 7.4 15 3.3 8.2 15 See all AHRI certified ratings at www.ahrinet.org.
|
|
|
+
|
|
|
+ 208-230 60 Three 14.5-13.4 32.6 45 14.5-13.4 35.9 45 Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+5.0 460 60 Three 6.7 15.1 20 6.7 16.6 20
|
|
|
+
|
|
|
+ 575 60 Three 5.3 11.9 15 5.3 13.1 15
|
|
|
+
|
|
|
+ 208-230 60 Three 21.0-19.0 47.3 60 21.0-19.0 52.0 60
|
|
|
+
|
|
|
+7.5 460 60 Three 9.5 21.4 25 9.5 23.5 25
|
|
|
+
|
|
|
+ 575 60 Three 7.6 17.1 20 7.6 18.8 20
|
|
|
+
|
|
|
+ 208-230 60 Three 27.0-24.4 60.8 80 27.0-24.4 66.8 80
|
|
|
+
|
|
|
+10.0 460 60 Three 12.2 27.5 35 12.2 30.2 35
|
|
|
+
|
|
|
+ 575 60 Three 9.76 22.0 30 9.76 24.2 30
|
|
|
+
|
|
|
+24 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ LE10XRT (RTV/RTR) Energy Recovery Ventilator Standard
|
|
|
+
|
|
|
+ 69 3/4" Minimum ABBREVIATIONS
|
|
|
+ Service Area EA: Exhaust Air to outside
|
|
|
+ OA: Outside Air intake
|
|
|
+ CURB LE10X Door Door RA Damper RA: Room Air to be exhausted
|
|
|
+ Swing Swing Location FA: Fresh Air to inside
|
|
|
+ 64 1/4" O.D. (Optional) RTV: Rooftop Vertical RA & FA
|
|
|
+ RTR: Rooftop Vertical RA Only
|
|
|
+ A A FA (RTV) OA INSTALLATION ORIENTATION
|
|
|
+ (2) 16 1/8" X 16 3/8" Unit must be installed in orientation
|
|
|
+ Openings RA shown.
|
|
|
+ 24" X 48" NOTE
|
|
|
+ 195 1/4" O.D. 9 1/2" Opening 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ 49" DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ 25" 191 1/2" I.D. EA OA NEAREST EIGHTH OF AN INCH.
|
|
|
+ 18 1/4" 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ 20" 3" TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ FA RA
|
|
|
+
|
|
|
+ 85 1/4" CURB CROSS-SECTION A-A (TYP.)
|
|
|
+ 58 1/4"
|
|
|
+ 41 1/8" FA RTR 72 1/8" 1 1/2" X 1/4" 1 7/8"
|
|
|
+ ONLY Neoprene Gasket
|
|
|
+
|
|
|
+ 60 1/2" I.D. 49 3/8" 3/4" X 3 1/2"
|
|
|
+ Wooden Nailer
|
|
|
+ TOP VIEW Door Door
|
|
|
+ 36" E-Box Swing Swing
|
|
|
+ Minimum 79 7/8" Minimum Blower Service Area Typ. 14"
|
|
|
+ Service Area 111" Minimum
|
|
|
+ Service Area
|
|
|
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 25 13 3/8" X 15 1/2" E-Box Pressure 4 1/2" 3"
|
|
|
+ Electrical TOP VIEW Ports
|
|
|
+ Disconnect (4) Typ. SECTION A-A
|
|
|
+ Connection Switch 111 1/4" Overall
|
|
|
+ Cover 84 5/8" 69 1/8" Case 205 3/8" Overall
|
|
|
+ 202 5/8" Case
|
|
|
+ 44 5/8" 47 1/4" 93 5/8"
|
|
|
+
|
|
|
+ 71 1/8" Overall EA OA
|
|
|
+ 69 5/8" Case
|
|
|
+ 37 7/8" FA RTR 4"
|
|
|
+ ONLY
|
|
|
+ 9"
|
|
|
+ CL 11 3/8" CL 2 1/4" FA OA Inlets
|
|
|
+ FA1 1/8" Wiring RTV OA Damper
|
|
|
+ RA ONLY
|
|
|
+ Knockouts Locations
|
|
|
+ 29 5/8" (Optional)
|
|
|
+ 53 1/2"HERT except 6x 8x, LERT
|
|
|
+
|
|
|
+ RA
|
|
|
+ FA (RTR) RA 2" Typ.
|
|
|
+ 48" X 24"
|
|
|
+ Duct Receiving CL 5 1/4" 2" Duct 73 3/8"
|
|
|
+ Flange
|
|
|
+ Flange LEFT VIEW (2)HERT 7ex/c8ep"t 6x 8x, LETRyTp. Lift Lugs
|
|
|
+ Knockouts RIGHT VIEW
|
|
|
+ FRONT VIEW
|
|
|
+
|
|
|
+ DMAArovaIaRdiwlaFbeLilnelO:agsLWsETh1yoCw0pOnXe: N:RFUTIVGn/UitRRDTARimTIOeNnsion EA RTV RTR UNIT MOUNTING & APPLICATION
|
|
|
+
|
|
|
+ OA EA OA Must be mounted as shown. Airstreams can not
|
|
|
+ be switched.
|
|
|
+ Version: MAY18 FA
|
|
|
+
|
|
|
+ LE-SERIES
|
|
|
+ SPECIFICATIONS & DIMENSIONS
|
|
|
+26 RENEWAIRE.COM 1.800.627.4499
|
|
|
+LE10XRT (RTH/RTF) Energy Recovery Ventilator Standard ABBREVIATIONS
|
|
|
+ EA: Exhaust Air to outside
|
|
|
+ 69 3/4" Minimum OA: Outside Air intake
|
|
|
+ Service Area RA: Room Air to be exhausted
|
|
|
+ FA: Fresh Air to inside
|
|
|
+ CURB LE10X Door Door RTF: Rooftop Vertical FA Only
|
|
|
+ Swing Swing RTH: Rooftop Horizontal RA & FA
|
|
|
+ 64 1/4" O.D. INSTALLATION ORIENTATION
|
|
|
+ Unit must be installed in orientation
|
|
|
+ A A FA (RTF) shown.
|
|
|
+ (2) 16 1/8" X 16 3/8" NOTE
|
|
|
+195 1/4" O.D. 9 1/2" Openings 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+ 49" DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ OA NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS MAY BE SUBJECT
|
|
|
+ EA TO CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 18 1/4"
|
|
|
+ 25" 191 1/2" I.D.
|
|
|
+ 85 1/4"
|
|
|
+ 20" 3" 58 1/4"
|
|
|
+
|
|
|
+ FA RA CURB CROSS-SECTION A-A (TYP.)
|
|
|
+
|
|
|
+ FA RTH OA 1 1/2" X 1/4"
|
|
|
+ ONLY
|
|
|
+ 1 7/8"
|
|
|
+ 41 1/8" Neoprene Gasket
|
|
|
+
|
|
|
+ 60 1/2" I.D. Door Door 3/4" X 3 1/2"
|
|
|
+ Swing Swing Wooden Nailer
|
|
|
+ TOP VIEW
|
|
|
+ 36" E-Box 79 7/8" 14"
|
|
|
+ Minimum Minimum
|
|
|
+ Service Area
|
|
|
+ Blower
|
|
|
+ 111" Minimum Service 3"
|
|
|
+ Service Area Area Typ.
|
|
|
+ SECTION A-A
|
|
|
+ 13 3/8" X 15 1/2" E-Box TOP VIEW Pressure 4 1/2"
|
|
|
+ Electrical Disconnect Ports 205 3/8" Overall
|
|
|
+ 111 1/8" Overall (4) Typ. 202 5/8" Case
|
|
|
+ Connection Switch 69 1/8" Case 93 5/8"
|
|
|
+ Cover 84 5/8" OA
|
|
|
+
|
|
|
+44 5/8" 47 1/4"
|
|
|
+
|
|
|
+71 1/8" Overall EA 8 7/8"
|
|
|
+ 69 5/8" Case
|
|
|
+ 37 7/8" 53 1/2" RTH 4"
|
|
|
+ 9" ONLY
|
|
|
+ FA RA
|
|
|
+
|
|
|
+ FA (RTH) CL 11 3/8" 29 5/8" FA 2" 47 3/8"
|
|
|
+ 48" X 24" (5) 1 1/8" Typ.
|
|
|
+ Duct Receiving Knockouts 2" Duct RTV, RTF RA Inlet RA Damper OA Inlets
|
|
|
+ ONLY 5" Damper 48" X 24" Location OA Damper
|
|
|
+ Frames Typ. Duct Receiving (Optional)
|
|
|
+ CL 5 1/4" Flange Typ. Flange Locations
|
|
|
+ (2) 7/8" RIGHT VIEW (Optional)
|
|
|
+ Flange KnocHEkRoTeuxctespt 6x 8x, CL 2 1/4" 73 3/8"
|
|
|
+ LERWT iring Lift Lugs
|
|
|
+ LEFT VIEW HERT except 6x 8x, LERT
|
|
|
+ FRONT VIEW
|
|
|
+
|
|
|
+DMAArovaIaRdiwlaFbeLilnelO:agsLWsETh1yoCw0pOnXe: N:RFUTIHGn/UitRRDTAFimTIOeNnsion RTH RTF UNIT MOUNTING & APPLICATION
|
|
|
+
|
|
|
+ EA OA EA OA Must be mounted as shown. Airstreams can not
|
|
|
+ FA RA be switched.
|
|
|
+ RA
|
|
|
+
|
|
|
+Version: MAY18 FA
|
|
|
+ OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+OPTIONS
|
|
|
+
|
|
|
+See individual submittal pages for availability by model.
|
|
|
+
|
|
|
+ELECTRICAL
|
|
|
+u Disconnect fuses and motor starters
|
|
|
+u Independent blower control (IBC) -
|
|
|
+
|
|
|
+ available as an option for HE1X and
|
|
|
+ HE1.5X
|
|
|
+
|
|
|
+VARIABLE FREQUENCY DRIVE
|
|
|
+
|
|
|
+u Factory supplied and mounted variable u Pre-programmed speeds or variable
|
|
|
+ frequency drives (VFDs) speed
|
|
|
+ - one or both airstreams
|
|
|
+ u Easy airflow setup using RenewAire’s
|
|
|
+u Provides additional control options standard pressure ports
|
|
|
+ - cuts commissioning time
|
|
|
+u Separate VFD for each airstream
|
|
|
+ u Shaft grounding ring on motors with
|
|
|
+u Display/control in electrical box - can be VFDs
|
|
|
+ remotely mounted
|
|
|
+
|
|
|
+ VFD all voltage VFD
|
|
|
+ except 575V 575V only
|
|
|
+
|
|
|
+MOTORIZED ISOLATION DAMPERS
|
|
|
+
|
|
|
+u Class 1, low leakage u Damper(s) are factory mounted and
|
|
|
+ wired (except in HE1XIN - shipped
|
|
|
+u Robust, reliable actuators for highest loose)
|
|
|
+ dependability
|
|
|
+
|
|
|
+u Automatic operation with spring return in
|
|
|
+ event of power loss
|
|
|
+
|
|
|
+FILTER ALARM
|
|
|
+
|
|
|
+u Factory mounted airflow switches -
|
|
|
+ one for each airstream
|
|
|
+
|
|
|
+u Allows for remote indication of loaded
|
|
|
+ (dirty) filter
|
|
|
+
|
|
|
+EXTERIOR PAINT
|
|
|
+u White and custom colors available
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 27
|
|
|
+OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+OPTIONS
|
|
|
+
|
|
|
+Integrated Programmable Controls
|
|
|
+
|
|
|
+AVAILABLE ON ALL EV450, HE, LE, RD AND DN-SERIES UNITS
|
|
|
+
|
|
|
+RenewAire’s I N T E G R AT E D P R O G R A M M A B L E
|
|
|
+C O N T R O L S optimize the usability and performance of our
|
|
|
+commercial ERVs by improving functionality, enabling intelligent
|
|
|
+controls, streamlining operations and boosting efficiencies. This is
|
|
|
+accomplished via sophisticated factory-installed microprocessor
|
|
|
+controls and sensors that provide stand-alone ERVs with Direct Digital
|
|
|
+Control (DDC) and/or Building Management System (BMS) control
|
|
|
+interface.
|
|
|
+
|
|
|
+KEY BENEFITS
|
|
|
+
|
|
|
+Optimize usability: Increase capabilities:
|
|
|
+u Maximize ERV functionality and intelligent control via remote u Expand ERV connectivity via access to a wide range of open
|
|
|
+
|
|
|
+ Ethernet accessibility and BMS connectivity without third-party standard protocols, including BACnet and Modbus.
|
|
|
+ interface.
|
|
|
+ u Broaden ERV interoperability by connecting to third-party
|
|
|
+u Streamline operations by easily managing and changing ERV equipment and receiving third-party signals for unit control.
|
|
|
+ control parameters via an advanced user interface.
|
|
|
+ u Expand ERV-application scope by meeting new code
|
|
|
+u Increase uptime reliability through constant system monitoring. requirements and the needs of institutional customers
|
|
|
+ requiring DDC controls in mechanical equipment.
|
|
|
+u Achieve cleaner and healthier indoor air via IAQ-based ERV control.
|
|
|
+
|
|
|
+Improve performance: Simplify operations:
|
|
|
+u Support effective and efficient ERV performance with real-time u Achieve easier ERV setup, commissioning and balancing via
|
|
|
+
|
|
|
+ data trending and logging capabilities. simple-to-install controls.
|
|
|
+
|
|
|
+u Enhance ERV control via access to real-time airflow rates, u Improve operational efficiencies by easily communicating ERV
|
|
|
+ airstream temperature and airstream humidity. status, airflows, temperatures and humidity.
|
|
|
+
|
|
|
+u Facilitate fast and easy ERV upkeep and maintenance with u Allow for more flexible installations by enabling ERVs to be
|
|
|
+ real-time fan, filter and bypass status. interconnected with a BMS, operated independently or run in
|
|
|
+ concert with other ERVs.
|
|
|
+
|
|
|
+A C C E S S O R I E S AVAILABLE WITH INTEGRATED PROGRAMMABLE CONTROLS
|
|
|
+
|
|
|
+ CO2 sensor (wall or duct mount)* STANDARD ENHANCED PREMIUM
|
|
|
+ IAQ sensor (wall or duct mount)* CONTROLS CONTROLS CONTROLS
|
|
|
+ Occupancy sensor (ceiling or wall mount)
|
|
|
+ Smoke detector (duct mount) u u u
|
|
|
+ BACnet factory activation (MS/TP or TCP/IP) u u u
|
|
|
+ Remote display (handheld or wall mount) u u u
|
|
|
+ Room Pressure Sensor (with or without display) u u
|
|
|
+ Duct Static Pressure Sensor (with or without display) u
|
|
|
+ Temperature Sensor Kit (wall or duct mount)** u
|
|
|
+ u
|
|
|
+NOTES u
|
|
|
+ u
|
|
|
+*Sensor output is 0-10 vdc, for use as on/off or modulating control.
|
|
|
+**Temperature Sensor Kit is for use with non-integrated heating.
|
|
|
+
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+28 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+OPTIONS
|
|
|
+
|
|
|
+Integrated Programmable Controls
|
|
|
+
|
|
|
+MODELS FEATURE COMPARISON
|
|
|
+
|
|
|
+STANDARD CONTROLS STANDARD
|
|
|
+ CONTROLS
|
|
|
+via dry contact and relays ENHANCED
|
|
|
+Our ERV units are provided with a dry contact CONTROLS
|
|
|
+that can be used to control the unit with a variety PREMIUM
|
|
|
+of low-voltage (24VAC) control devices such as CONTROLS
|
|
|
+remote switches or relays. In addition, third-party
|
|
|
+analog output can be used to operate the ERV. Ability to automatically enable and disable unit u u u
|
|
|
+
|
|
|
+ENHANCED CONTROLS Enable the exhaust fan only (See note 1) u u u
|
|
|
+
|
|
|
+Carel [c.pCOMini] with or without BACnet Filter alarm for both sets of filters (See note 2) u u u
|
|
|
+Enhanced controls offer automated control,
|
|
|
+including temperature and humidity control with Bypass controls† (See note 3) u u u
|
|
|
+data trending via microprocessor controls and
|
|
|
+sensors that enable BMS connectivity. Control isolation dampers† (See note 4) u u u
|
|
|
+
|
|
|
+PREMIUM CONTROLS Supply fan only modulation for VFD/EC Motor units† u u u
|
|
|
+
|
|
|
+Carel [c.pCOMini] with expansion module (See note 5 and 6) u u u
|
|
|
+with or without BACnet
|
|
|
+Premium controls include all functionality of Exhaust fan only modulation for VFD/EC Motor units† u u u
|
|
|
+Enhanced-controls capabilities, as well as
|
|
|
+airflow and IAQ monitoring, demand control, (See note 5 and 6)
|
|
|
+electric or gas heating options, as well as
|
|
|
+RD-Series cooling and heating control. Internal time clock (See note 7)
|
|
|
+
|
|
|
+ Defrost controls - Canada only u u u
|
|
|
+
|
|
|
+ Smoke detection - sensor required (See note 8) u u u
|
|
|
+
|
|
|
+ Demand control ventilation using CO2 - sensor required u u
|
|
|
+
|
|
|
+ Occupancy-based ventilation - sensor required u u
|
|
|
+
|
|
|
+ IAQ control ventilation using VOC - sensor required u u
|
|
|
+
|
|
|
+ Microprocessor controller u u
|
|
|
+
|
|
|
+ Provide supply and exhaust air temperatures u u
|
|
|
+
|
|
|
+ Provide outside and return air temperature and humidity† u u
|
|
|
+
|
|
|
+ Fan status on both fans†† u u
|
|
|
+
|
|
|
+ Enable the supply fan only† u u u
|
|
|
+
|
|
|
+ Enable the exhaust fan only† u u u
|
|
|
+
|
|
|
+ Micro USB port u u
|
|
|
+
|
|
|
+ Fieldbus port u u
|
|
|
+
|
|
|
+ BACnet MS/TP or BACnet TCP/IP - activation required u u
|
|
|
+
|
|
|
+ Modbus u u
|
|
|
+
|
|
|
+ Data trending u u
|
|
|
+
|
|
|
+ Outside airflow rate u
|
|
|
+
|
|
|
+ Exhaust airflow rate u
|
|
|
+
|
|
|
+ Space pressure control u
|
|
|
+
|
|
|
+ Duct pressure control u
|
|
|
+
|
|
|
+ Unit supply air temp u
|
|
|
+
|
|
|
+ Heating enable u
|
|
|
+
|
|
|
+ Heating modulation - staged or modulating u
|
|
|
+
|
|
|
+ Cooling modulation* - staged or modulating u
|
|
|
+
|
|
|
+ *RD-Series units only †Not available on EV450 ††EF fan status not available on EV450
|
|
|
+
|
|
|
+ NOTES FOR STANDARD CONTROLS ONLY 5. VFD (option). Factory installed and wired.
|
|
|
+ 6. EC Motor (option) Potentiometer control factory wired.
|
|
|
+ 1. Relays and terminal block (option). 7. Independent time clock (option).
|
|
|
+ 2. Differential pressure sensing tube and pressure switch 8. External smoke detector (option), field installed
|
|
|
+
|
|
|
+ with manual trip point adjustment (option), wiring in series to shut off unit in adverse conditions.
|
|
|
+ to switch and alarm indication provided by others.
|
|
|
+ 3. Option on HE-Series (IN) and standard on RD-Series.
|
|
|
+ 4. 24V transformer contactors and relays (option).
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 29
|
|
|
+OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+ACCESSORIES
|
|
|
+
|
|
|
+Standard Controls
|
|
|
+
|
|
|
+Standard controls are intended to turn RenewAire commercial energy recovery ventilation systems on and off at appropriate times.
|
|
|
+Specification, installation and set-up is an easy process. RenewAire HE, LE, and RD Series units come standard with a 24 volt
|
|
|
+transformer/relay package for easy interface with all controls.
|
|
|
+
|
|
|
+It is not necessary that RenewAire controls be used to operate RenewAire units. A wide range of controls or building automation
|
|
|
+systems may be used.
|
|
|
+
|
|
|
+*Available with Standard or Integrated Programmable Controls.
|
|
|
+**Only available with Integrated Programmable Controls.
|
|
|
+
|
|
|
+DIGITAL TIME CLOCK*
|
|
|
+
|
|
|
+u Up to 8 on/off cycles per day or 56 per u Battery back-up box
|
|
|
+
|
|
|
+week u Wall mount or outdoor enclosure options
|
|
|
+
|
|
|
+u 24 VAC power requirement u Wall mount fits any 4" x 4" electrical
|
|
|
+
|
|
|
+ TC7D-W
|
|
|
+ Wall Mount
|
|
|
+
|
|
|
+ TC7D-E Control In
|
|
|
+ NEMA 3R Enclosures
|
|
|
+
|
|
|
+CO2 SENSORS* u Self calibrates during periods of low
|
|
|
+u Adjustable control from 400-2000 PPM occupancy
|
|
|
+u Digital display
|
|
|
+u 24 VAC power requirement u Wall mount or add duct mount accessory
|
|
|
+u Computer/BAS interface for information and
|
|
|
+ CO2-D
|
|
|
+ control Duct Mount
|
|
|
+
|
|
|
+ CO2-W
|
|
|
+ Wall Mount
|
|
|
+
|
|
|
+IAQ SENSORS* u Selectable 0-5 or 0-10V dc signal
|
|
|
+ u 24 VAC power required
|
|
|
+u Measures TVOC u Internal menu for easy set-up
|
|
|
+u Direct correlation to CO2 levels
|
|
|
+u 0-2000 ppm CO2 equivalent output IAQ-D
|
|
|
+ Duct Mount
|
|
|
+ signal
|
|
|
+u Digital display on wall mount
|
|
|
+
|
|
|
+ IAQ-W
|
|
|
+ Wall Mount
|
|
|
+
|
|
|
+MOTION OCCUPANCY SENSORS*
|
|
|
+
|
|
|
+u Passive infared sensor u Coverage floor space
|
|
|
+u Adjustable time-off delay to 30 minutes
|
|
|
+u 24 VAC power requirement - Ceiling mount: 1500 sq. ft.
|
|
|
+u Ceiling mount or directable wall mount - Wall mount: 2500 sq. ft.
|
|
|
+
|
|
|
+ u Major motion area MC-C MC-W
|
|
|
+ Ceiling Mount Wall Mount
|
|
|
+ - Ceiling mount: 50 ft. diameter
|
|
|
+ - Wall mount: 68 x 50 ft.
|
|
|
+
|
|
|
+SMOKE DETECTOR* u For 100-4000 fpm duct air velocity SD-D
|
|
|
+ applications Duct Mount
|
|
|
+u Photoelectric type detector
|
|
|
+u Plug-in sensor u 24 VAC power requirement
|
|
|
+u Round, square or rectangular duct
|
|
|
+ u Interconnect feature for multi-fan
|
|
|
+ mounting options shutdown
|
|
|
+u Easy access test/reset button and LED
|
|
|
+ u Built-in short circuit protection
|
|
|
+ display
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+30 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+ACCESSORIES
|
|
|
+
|
|
|
+Controls Continued
|
|
|
+
|
|
|
+REMOTE DISPLAY**
|
|
|
+
|
|
|
+u Hand held or wall mount
|
|
|
+u LED display
|
|
|
+u Keypad for easy programming
|
|
|
+
|
|
|
+ RD-M
|
|
|
+ Handheld or Wall Mount
|
|
|
+
|
|
|
+PRESSURE SENSORS (ROOM PRESSURE/DUCT STATIC PRESSURE)**
|
|
|
+
|
|
|
+u With or without display
|
|
|
+
|
|
|
+u Differential pressure transmitter
|
|
|
+
|
|
|
+u 4-20 mA or field selectable 0-10 & 0.5V
|
|
|
+ output signal
|
|
|
+
|
|
|
+u Integral barbed tubing connections that
|
|
|
+ fit 1/8" and 3/16" ID tubing
|
|
|
+
|
|
|
+ RPS-WOD/DPS-WOD RPS-WD/DPS-WD
|
|
|
+ Wall/Duct Mount Wall/Duct Mount
|
|
|
+ without Display
|
|
|
+ with Display
|
|
|
+
|
|
|
+BACNET FACTORY ACTIVATION** BN-A
|
|
|
+
|
|
|
+u Allows for communication to a BAS via
|
|
|
+ Bacnet NS/TP
|
|
|
+
|
|
|
+u Factory programmed and tested
|
|
|
+
|
|
|
+TEMPERATURE SENSOR KIT**
|
|
|
+u Duct temperature sensors
|
|
|
+u Hermetically sealed 304SS probe
|
|
|
+u Operating range -40F to 210F
|
|
|
+u Easy installation with integral
|
|
|
+
|
|
|
+ mounting plate
|
|
|
+
|
|
|
+Engineered Combo Curbs TS
|
|
|
+ Wall/Duct Mount
|
|
|
+Exclusively designed for select Trane (Voyager and Precedent)
|
|
|
+and Carrier (WeatherExpert, WeatherMaster, and Weathermaker) Available Options (Special Order)
|
|
|
+models, RenewAire’s engineered combo curb makes it easy to u Seismic and/or wind load applications
|
|
|
+combine standard Air Handling Unit (AHU) rooftop applications u Pitched roof applications
|
|
|
+with the benefits of RenewAire energy recovery ventilation. u High vibration applications
|
|
|
+They eliminate the need for transitional ductwork between the u Custom curb heights
|
|
|
+RTU and the ERV, reducing the time and costs of installation. u Heavier metal gauges
|
|
|
+Simply install the curb, run the return and supply duct to the u Aluminum liners
|
|
|
+curb openings, then install the AHU and RenewAire units onto the
|
|
|
+curb. Additionally, the curbs allow the AHU unit to function in its
|
|
|
+standard operation as well as full-flow economizer modes.
|
|
|
+
|
|
|
+Standard Construction
|
|
|
+u Prime G-90, 18-gauge galvanized steel
|
|
|
+u Fully welded and mitered corners (single piece curb lift)
|
|
|
+u Base flange attachments for securing to the building structure
|
|
|
+u 1 ½" 3 lb. density fiberglass insulation
|
|
|
+u Reinforced with cross channel supports on center
|
|
|
+u Conforms to ASTM A653/A653M (standard specification for sheet metal)
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 31
|
|
|
+OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+ACCESSORIES
|
|
|
+
|
|
|
+EK Series Electric Duct Heater
|
|
|
+
|
|
|
+AVA I L A B L E O N A L L C O M M E R C I A L U N I T S ( S O M E E X C E P T I O N S A P P LY )
|
|
|
+
|
|
|
+RenewAire offers the highest-efficiency energy recovery ventilators (ERVs) on the market. However, during
|
|
|
+winter conditions, supply air from the ERV may be less than optimal for space conditions. By adding
|
|
|
+C O N F I G U R A B L E E L E C T R I C D U C T H E AT E R S as an accessory to our
|
|
|
+commercial ERVs, RenewAire can now heat supply air during cooler months to enhance indoor comfort,
|
|
|
+all via one package for ERVs and heaters from a single source.
|
|
|
+
|
|
|
+ FLIPPABLE
|
|
|
+ EK SERIES
|
|
|
+ SHOWN
|
|
|
+
|
|
|
+KEY BENEFITS
|
|
|
+
|
|
|
+u A single source reduces time and costs: A single information u Ultimate reliability: RenewAire heaters come with our
|
|
|
+ source, a single purchase point and a single approval package two-year warranty and unmatched reliability. Single-source
|
|
|
+ for ERVs and heaters reduces design time and costs, and responsibility offers contractors and end users peace of
|
|
|
+ streamlines logistics for design engineers and contractors. mind and a single call location for technical, start-up and
|
|
|
+ commissioning questions.
|
|
|
+u More flexibility: RenewAire offers design engineers the
|
|
|
+ capacity to specify ERVs with a matching heater to boost u Highly certified: UL Listed (UL1996 Standard) and CSA certified.
|
|
|
+ flexibility and provide heated air to a single space or
|
|
|
+ multiple spaces.
|
|
|
+
|
|
|
+u Easy installation: A ZERO clearance rating to combustibles
|
|
|
+ allows designers and contractors to apply RenewAire heaters
|
|
|
+ with less restrictions onsite.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+32 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+EK SERIES Electric Duct Heater (1-175 kW)
|
|
|
+ Accessory
|
|
|
+ELECTRIC DUCT HEATER
|
|
|
+ SPECIFICATIONS
|
|
|
+Download specification at:
|
|
|
+renewaire.com/specifications Heater Type: Voltages & Phase:
|
|
|
+ Electric Duct Heater Single phase - 120, 208, 240, 277
|
|
|
+ Three phase - 208, 240, 480, 600
|
|
|
+ Typical KW Range:
|
|
|
+ 1–175 kW Control Voltage:
|
|
|
+ 24 VAC
|
|
|
+ Standard Features:
|
|
|
+ A disconnecting magnetic control contactor per Dimensions:
|
|
|
+ Minimum - 8" x 8" (W x H)
|
|
|
+ stage or each 48 Amp circuit within a stage Maximum - 99" x 99" (W x H)
|
|
|
+ Open-coil element
|
|
|
+ Staged on/off Options:
|
|
|
+ Control terminal board Flange mount
|
|
|
+ Grounding lugs 80-20 (Ni/Cr) A Grade element wire with
|
|
|
+ Automatic limit switch for primary over-
|
|
|
+ stainless steel terminals
|
|
|
+ temperature protection Recessed control box 1"
|
|
|
+ Manual reset limit switch for secondary over- Gasketed cover - dust tight
|
|
|
+ Power fusing, standard for heaters drawing more
|
|
|
+ temperature protection
|
|
|
+ Non-adjustable airflow switch than 48 Amps
|
|
|
+ Standard control transformer - 24 VAC 2-stage
|
|
|
+ Disconnect switch Electronic step controller (4-stage)
|
|
|
+ Duct thermostat with sensor for on/off control SCR (up to 96 Amps)
|
|
|
+ 60-20-20 (Ni/Cr/Fe) C Grade element wire with SCR Vernier (over 96 Amps)
|
|
|
+ Pilot light
|
|
|
+ nickel-plated terminals
|
|
|
+ Slip-in mount Accessory:
|
|
|
+ No left/right hand Room thermostat
|
|
|
+ Vertical up/down flow Room/duct thermostat-sensor kit for SCR control
|
|
|
+
|
|
|
+ Note: Electric duct heater designed for indoor ductwork installation only.
|
|
|
+
|
|
|
+ EK SEREIKESSeHrieEsAHTeaEteRr CCaApaPcAityCITY PRESSURPEREDSRSOUPRETHDRROOPUGTHHRHOEUAGTHERHEATER
|
|
|
+
|
|
|
+200 0.18
|
|
|
+
|
|
|
+175HEATER CAPACITY - kW 0.16 4
|
|
|
+
|
|
|
+150 Static Pressure Drop - Inches of Water 0.14
|
|
|
+
|
|
|
+ 3
|
|
|
+
|
|
|
+ 0.12
|
|
|
+
|
|
|
+125 0.1
|
|
|
+
|
|
|
+100 0.08 2
|
|
|
+
|
|
|
+ 0.06
|
|
|
+
|
|
|
+75
|
|
|
+
|
|
|
+ SAFE OPERATING 0.04
|
|
|
+
|
|
|
+50 RANGE 1
|
|
|
+
|
|
|
+ 0.02
|
|
|
+
|
|
|
+25 0
|
|
|
+ 0
|
|
|
+ 200
400
600
800
1000
1200
1400
1600
1800
2000
2200
|
|
|
+
|
|
|
+0 Air Velocity - FPM (1, 2, 3 and 4 - the number of rows of heater coils)
|
|
|
+ When the number of rows of heater coils is unknown, assume 4.
|
|
|
+ 0 2500 5000 7500 10000 12500
|
|
|
+
|
|
|
+ AIRFLOW - CFM
|
|
|
+
|
|
|
+ FLIPPABLE
|
|
|
+ CAPABILITIES
|
|
|
+
|
|
|
+ Unique to the EK series, this unit has the ability
|
|
|
+ to flip 180°. Additionally, EK heaters feature
|
|
|
+ both vertical up and vertical down airflow.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 33
|
|
|
+ T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
|
|
|
+
|
|
|
+34 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+ACCESSORIES
|
|
|
+
|
|
|
+Indirect Gas-Fired Duct Furnace
|
|
|
+
|
|
|
+AVA I L A B L E O N A L L C O M M E R C I A L U N I T S ( S O M E E X C E P T I O N S A P P LY )
|
|
|
+
|
|
|
+RenewAire offers some of the highest-efficiency energy recovery ventilators (ERVs) on the market. However,
|
|
|
+during winter conditions, supply air from the ERV may be less than optimal for space conditions. By providing
|
|
|
+an indoor and outdoor I N D I R E C T G A S - F I R E D D U C T F U R N A C E as an accessory
|
|
|
+for our commercial ERVs, in addition to the Electric Duct Heater, RenewAire ERVs now have increased
|
|
|
+flexibility for controlling supply-air temperature during cooler months. This enhances indoor comfort, makes
|
|
|
+ERV installations easier and is possible via a single source for ERVs and furnaces.
|
|
|
+
|
|
|
+ GH OUTDOOR SERIES
|
|
|
+ SHOWN
|
|
|
+
|
|
|
+KEY BENEFITS
|
|
|
+
|
|
|
+u A single source for your ERV and furnace reduces time and u Expert guidance: The RenewAire customer-support team will
|
|
|
+ costs: A single information source, a single purchase point and provide detailed and expert guidance for how best to install the
|
|
|
+ a single approval package for ERVs and heaters reduces design indoor and outdoor gas-fired duct furnace with an ERV.
|
|
|
+ time and costs, as well as streamlines logistics for design
|
|
|
+ engineers and contractors. u Ultimate reliability: RenewAire furnaces come with our
|
|
|
+ two-year warranty and unmatched reliability. Single-source
|
|
|
+u Increased capabilities and flexibility: RenewAire offers responsibility offers contractors and end users peace of
|
|
|
+ design engineers the capacity to specify ERVs with a matching mind and a single call location for technical, start-up and
|
|
|
+ indoor or outdoor gas-fired furnace to increase ERV capabilities commissioning questions.
|
|
|
+ and flexibility for providing a single space or multiple spaces
|
|
|
+ with tempered air conditions to equal wintertime loads. u Highly certified: ETL-listed to the requirements of ANSI Z83.8/
|
|
|
+ CSA 2.6.
|
|
|
+u More and easier applications: The addition of the indoor
|
|
|
+ and outdoor indirect gas-fired duct furnace as an option
|
|
|
+ ensures that RenewAire ERVs can be easily specified on more
|
|
|
+ applications that require gas heating of the recovered air.
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 35
|
|
|
+OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+GH INDOOR Indirect Gas-Fired Duct Furnace
|
|
|
+ Accessory
|
|
|
+
|
|
|
+INDOOR SPECIFICATIONS Standard Features (continued):
|
|
|
+Indirect Gas-Fired Duct Furnace Flame rollout switch
|
|
|
+ Heater Type: Manual shut off valve
|
|
|
+ Indoor IN-KI shown Indirect Gas-Fired Duct Furnace 3/8" condensate drain connection
|
|
|
+Download specification at:
|
|
|
+renewaire.com/specifications Typical Input Capacity (MBH): Voltages & Phase:
|
|
|
+ 50, 75, 100, 125, 150, 175, Single phase - 120V, 208V, 230V
|
|
|
+ 200, 250, 300, 350, 400
|
|
|
+ Control Voltage:
|
|
|
+ Standard Features: 24 VAC
|
|
|
+ Tubular heaters
|
|
|
+ Indirect natural gas fired Dimensions:
|
|
|
+ Indoor installation See table 2
|
|
|
+ 80% thermal efficiency
|
|
|
+ Horizontal airflow Shipping:
|
|
|
+ Rated for elevations from 0 – 2,000 ft. Shipped loose with base unit and installed in the field
|
|
|
+ 409 stainless steel heat exchanger
|
|
|
+ 409 stainless steel burners Options:
|
|
|
+ Flue/combustion air – indoor models Indirect propane fired fuel
|
|
|
+ Elevation correction for elevation > 2,000 ft.
|
|
|
+ Vertical (separated indoor) 304 stainless steel heat exchanger
|
|
|
+ Vertical top exhaust with louvered intake 5:1 continuous electronic modulation for all furnaces
|
|
|
+ Direct spark ignition 10:1 continuous electronic modulation for furnaces
|
|
|
+ 1-stage/2-stage gas controls
|
|
|
+ Induced draft venting 200 MBH and larger
|
|
|
+ Terminal block for power and control wiring Duct thermostat for modulation control
|
|
|
+ Automatic high limit safety shut-off Disconnect switch
|
|
|
+ Auxiliary manual high limit switch Power fusing
|
|
|
+ Combustion air pressure switch
|
|
|
+ Air proving switch Accessory:
|
|
|
+ Combination gas valve with shutoff Duct thermostat for 1-stage/2-stage control
|
|
|
+ Duct thermostat for modulation control
|
|
|
+
|
|
|
+FLUE AND COMBUSTION AIR CONFIGURATION
|
|
|
+
|
|
|
+ IN-KI IN-SI Note: The total equivalent length of vent pipe must not exceed 50 feet. If equivalent length exceeds 50 feet refer
|
|
|
+ (TOP EXHAUST) (SEPARATE INLET EXHAUST) to IOM for recommendations.
|
|
|
+
|
|
|
+ FLUE FLUE COMBUSTION Caution: All indirect gas-fired duct furnaces to be installed downstream of the ERV and on the positive side of the
|
|
|
+EXHAUST EXHAUST INTAKE supply fan.
|
|
|
+
|
|
|
+AIRFLOW AIRFLOW AIRFLOW AIRFLOW
|
|
|
+
|
|
|
+ COMBUSTION
|
|
|
+ INTAKE
|
|
|
+
|
|
|
+TEMPERATURE RISE AND PRESSURE DROP
|
|
|
+
|
|
|
+ FIGURE 1 GAS FURNACE 50-200 MBH FIGURE 2 GAS FURNACE 250-400 MBH
|
|
|
+
|
|
|
+ Gas Furnace 50 ‐ 200 MBH Gas Furnace 250 ‐ 400 MBH
|
|
|
+
|
|
|
+60 0.32 60 1.6
|
|
|
+
|
|
|
+55 0.28 55 1.4
|
|
|
+
|
|
|
+50 200 50 1.2
|
|
|
+45
|
|
|
+40 0.24
|
|
|
+Temperature Rise (deg. F)35 400
|
|
|
+ Pressure Drop (inch‐w.c.)30
|
|
|
+ Temperature Rise (deg. F)252001750.2045 400 350
|
|
|
+ Pressure Drop (in.‐w.c.)20175
|
|
|
+ 150 0.16 350 1.0
|
|
|
+ 0
|
|
|
+ 40 300
|
|
|
+
|
|
|
+ 300 0.8
|
|
|
+
|
|
|
+ 125 0.12 35 250 250 0.6
|
|
|
+ 100
|
|
|
+ 75 150 0.08 30 0.4
|
|
|
+ 50 125
|
|
|
+ 100
|
|
|
+ 0.04 25 0.2
|
|
|
+ 50/75
|
|
|
+
|
|
|
+ 1000 2000 3000 4000 5000 6000 0.00 20 3000 4000 5000 6000 7000 8000 0.0
|
|
|
+ 7000 2000 Airflow (CFM) 9000 10000 11000 12000
|
|
|
+
|
|
|
+ Airflow (CFM)
|
|
|
+
|
|
|
+ Specifications may be subject to change without notice.
|
|
|
+36 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+ DUCT FURNACE DIMENSIONS FIGURE 4 IN-SI (SEPARATE INLET EXHAUST INDOOR)
|
|
|
+ FIGURE 3 IN-KI (TOP EXHAUST INDOOR)
|
|
|
+ 22.92 FLUE GAS EXHAUST 22.92
|
|
|
+ FLUE GAS EXHAUST (H) D (H)
|
|
|
+ D
|
|
|
+ 14.89 COMBUSTION AIR INLET 14.89
|
|
|
+ COMBUSTION AIR INLET D
|
|
|
+
|
|
|
+ 23.99 23.99
|
|
|
+ OUTDOOR TOP EXHAUST (NO)
|
|
|
+ OUTDOOR TOP EXHAUST (NO)
|
|
|
+ 47.85 47.85
|
|
|
+ (L) (L)
|
|
|
+
|
|
|
+ W UNLESS OTHERWISE SPECIFIED, RenewAire LLC 4510 Helgesen Dr. W UNLESS OTHERWISE SPECIFIED, RenewAire LLC 4510 Helgesen Dr.
|
|
|
+ DIMENSIONS ARE IN INCHES. Madison, WI 53718 USA DIMENSIONS ARE IN INCHES. Madison, WI 53718 USA
|
|
|
+ TABLE 2 TOLERANCES: TOLERANCES:
|
|
|
+ LINEAR 0.015 TEL: (608) 221-4499 TEL: (608) 221-4499
|
|
|
+ LEVEL DESCRIPTION OF REVISION HOLE SIZE 0.005 FAX: (608) 221-2824 FAX: (608) 221-2824
|
|
|
+ ANGULARITY 3 TOLL FREE: (800) 627-4499 TOLL FREE: (800) 627-4499
|
|
|
+ Size Tubes Input Rate SURFACE FINISH = LINEAR 0.015
|
|
|
+ HOLE SIZE 0.005
|
|
|
+ DESCRIPTION OF REVISION 63 MICROINCH MINIMUM TITLE: HDG-400-M-N GAS HEATER OUTDOOR ANGULARITY 3 TITLE: HDG-400-M-N GAS HEATER OUTDOOR
|
|
|
+ SURFACE FINISH =
|
|
|
+
|
|
|
+ 63 MICROINCH MINIMUM
|
|
|
+
|
|
|
+ MATERIAL: DRAWN BY: DATE: DWG. NO. - MATERIAL: DRAWN BY: DATE: DWG. NO.
|
|
|
+ INDOOR TOP EXHAUST (KI) -
|
|
|
+ DO NOT SCALE DRAWING. CAH 10/19/16 SK4750A DO NOT SCALE DRAWING. CAH 10/19/16 SK4750A
|
|
|
+ REMOVE ALL BURRS, BREAK REMOVE ALL BURRS, BREAK
|
|
|
+ SHARP EDGES. SHARP EDGES.
|
|
|
+ APPLICABLE STANDARDS: DIM.
|
|
|
+ AND TOL. ANSI Y14.5
|
|
|
+ APPLICABLE STANDARDS: DIM. Vent Locations INDOOR SEPARATED COMBUSTION (SI) DATE
|
|
|
+ AND TOL. ANSI Y14.5 FINISH:
|
|
|
+ ReneMwiAni/rMe aLLxCTemperature Rise through Furnace (°F) FINISH:CHECKED BY:DATE: SIZE A BY CHECKED BY: DATE: SIZE A SHEET 1 OF 1
|
|
|
+
|
|
|
+ BY
|
|
|
+ UNLESS OTHERWISE SPECIFIED,
|
|
|
+ DIMENSIONS ARE IN INCHES.
|
|
|
+ TOLERANCES:
|
|
|
+ DATE -- -- SCALE:1:16 SHEET 1 OF 1 4510 Helgesen Dr. LEVEL DESCRIPTION OF REVISION -- -- SCALE:1:16
|
|
|
+ Madison, WI 53718 USA
|
|
|
+ Shipping 4510 Helgesen Dr.
|
|
|
+ TEL: (608) 221-4499 Madison, WI 53718 USA
|
|
|
+ FAX: (608) 221-2824 TEL: (608) 221-4499
|
|
|
+ TOLL FREE: (800) 627-4499 FAX: (608) 221-2824
|
|
|
+ LINEAR 0.015 UNLESS OTHERWISE SPECIFIED, Unit RenewAire LLC Weight TOLL FREE: (800) 627-4499
|
|
|
+ HOLE SIZE 0.005
|
|
|
+ TITLE: HDG100-M-KI IN-KI, IN-SI DIMENSIONS ARE IN INCHES. Diameter Weight TITLE: HDG100-M-KI
|
|
|
+ OutputANGULARITY 3 TOLERANCES:
|
|
|
+ SURFACE FINISH = LINEAR 0.015
|
|
|
+ 20 63 MICROINCH MINIMUM 25 30 DO NOT SCALE DRAWING. 35DATE: 40 DWG. NO. 45 50 55 60 HOLE SIZE 0.005
|
|
|
+ MATERIAL: ANGULARITY 3
|
|
|
+ DRAWN BY: SURFACE FINISH =
|
|
|
+
|
|
|
+ REMOVE ALL BURRS, BREAK SK4700A "W" "L" "H" 63 MICROINCH MINIMUM "D" DO NOT SCALE DRAWING.
|
|
|
+ SHARP EDGES.
|
|
|
+ APPLICABLE STANDARDS: DIM. CHECKED BY: DRAWN BY: DATE: DWG. NO.
|
|
|
+ FINISH: AND TOL. ANSI Y14.5 DATE: MATERIAL:
|
|
|
+ SK4700A
|
|
|
+LEVEL DATE BY SCALE:1:24 SIZE A SHEET 4 OF 4 REMOVE ALL BURRS, BREAK
|
|
|
+ SHARP EDGES.
|
|
|
+ APPLICABLE STANDARDS: DIM. CHECKED BY:
|
|
|
+ FINISH: AND TOL. ANSI Y14.5 DATE: SIZE A
|
|
|
+
|
|
|
+ MBH Qty. Btuh Btuh LEVEL DESCRIPTION OF REVISION DATE BY inch inch lb SCALE:1:24 SHEET 3 OF 4
|
|
|
+
|
|
|
+ Nom. Duct Opening Airflow (CFM) inch inch lb
|
|
|
+
|
|
|
+ 50 3 50,000 40,000 1852 1481 1235 1058 926 823 741 673 617 15.7 127 207
|
|
|
+
|
|
|
+ 75 3 75,000 60,000 2778 2222 1852 1587 1389 1235 1111 1010 926 15.7 127 207
|
|
|
+
|
|
|
+ 100 4 100,000 80,000 3704 2963 2469 2116 1852 1646 1481 1347 1235 18.4 5 142 222
|
|
|
+ 125 5 125,000 100,000 4630 3704 3086 2646 2315 2058 1852 1684 1543 21.2
|
|
|
+ 169 249
|
|
|
+
|
|
|
+ 150 6 150,000 120,000 5556 4444 3704 3175 2778 2469 2222 2020 1852 23.9 160 240
|
|
|
+
|
|
|
+ 175 7 175,000 140,000 6481 5185 4321 3704 3241 2881 2593 2357 2160 26.7 47.8 22.9 180 260
|
|
|
+
|
|
|
+ 200 8 200,000 160,000 7407 5926 4938 4233 3704 3292 2963 2694 2469 29.4 196 276
|
|
|
+
|
|
|
+ 250 10 250,000 200,000 9259 7407 6173 5291 4630 4115 3704 3367 3086 34.9 245 325
|
|
|
+
|
|
|
+ 300 12 300,000 240,000 11111 8889 7407 6349 5556 4938 4444 4040 3704 40.4 6 279 384
|
|
|
+
|
|
|
+ 350 14 350,000 280,000 12963 10370 8642 7407 6481 5761 5185 4714 4321 45.9 324 429
|
|
|
+
|
|
|
+ 400 15 400,000 320,000 14815 11852 9877 8466 7407 6584 5926 5387 4938 48.7 394 499
|
|
|
+
|
|
|
+ Note: For a single furnace, 20° F minimum temperature rise, 60° F maximum temperature rise.
|
|
|
+ INDIRECT GAS-FIRED DUCT FURNACE DIMENSIONS
|
|
|
+
|
|
|
+ NOTES
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS SUBJECT TO
|
|
|
+ CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ TOP VIEW
|
|
|
+
|
|
|
+ 36"
|
|
|
+ Service Area
|
|
|
+
|
|
|
+ 14 7/8" 47 3/8"
|
|
|
+ Opening Case
|
|
|
+
|
|
|
+ 6 1/8" View Port 25" 14 7/8"
|
|
|
+ Case Opening
|
|
|
+
|
|
|
+ 6 1/8"
|
|
|
+
|
|
|
+ 24" 24"
|
|
|
+
|
|
|
+ 3" Opening 3/8" Condensate Opening 3"
|
|
|
+ LEFT VIEW
|
|
|
+ Power Wiring and Drain Tube
|
|
|
+
|
|
|
+ Control Wiring 3/4" Gas Connection RIGHT VIEW
|
|
|
+ Inlet Fittings FRONT VIEW
|
|
|
+
|
|
|
+ UNLESS OTHERWISE SPECIFIED, RenewAire LLC Specifications may be subject to change without 4510 Helgesen Dr. notice.
|
|
|
+ DIMENSIONS ARE IN INCHES. Madison, WI 53718 USA
|
|
|
+ TOLERANCES: TEL: (608) 221-4499
|
|
|
+ FAX: (608) 221-2824
|
|
|
+ TOLL FREE: (800) 627-4499
|
|
|
+ LINEAR 0.015
|
|
|
+ HDG100-M-KI DIM SPEC HOLE SIZE 0.005 37
|
|
|
+
|
|
|
+ ANGULARITY 3
|
|
|
+ FOTIRTLET:HE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM
|
|
|
+
|
|
|
+ SURFACE FINISH =
|
|
|
+ 63 MICROINCH MINIMUM
|
|
|
+
|
|
|
+ DRAWN BY: DATE: DWG. NO.
|
|
|
+OPTIONS & ACCESSORIES
|
|
|
+
|
|
|
+GH OUTDOOR Indirect Gas-Fired Duct Furnace
|
|
|
+ Accessory
|
|
|
+
|
|
|
+ROOFTOP SPECIFICATIONS Standard Features (continued):
|
|
|
+Indirect Gas-Fired Duct Furnace Combination gas valve with shutoff
|
|
|
+ Heater Type: Flame rollout switch
|
|
|
+ Rooftop RT-NO shown Indirect Gas-Fired Duct Furnace Manual shut off valve
|
|
|
+Download specification at: 3/8" condensate drain connection
|
|
|
+renewaire.com/specifications Typical Input Capacity (MBH):
|
|
|
+ 50, 75, 100, 125, 150, 175, Voltages & Phase:
|
|
|
+ 200, 250, 300, 350, 400 Single phase - 120V, 208V, 230V
|
|
|
+
|
|
|
+ Standard Features: Control Voltage:
|
|
|
+ Tubular heaters 24 VAC
|
|
|
+ Indirect natural gas fired
|
|
|
+ Outdoor installation Dimensions:
|
|
|
+ 80% thermal efficiency See table 1
|
|
|
+ Horizontal airflow
|
|
|
+ Rated for elevations from 0 – 2,000 ft. Shipping:
|
|
|
+ 409 stainless steel heat exchanger Shipped loose with base unit and installed in the field
|
|
|
+ 409 stainless steel burners
|
|
|
+ Flue/combustion air – outdoor models Options:
|
|
|
+ Indirect propane fired fuel
|
|
|
+ Horizontal separated outdoor with hoods Elevation correction for elevation > 2,000 ft.
|
|
|
+ Vertical top exhaust with intake hood 304 stainless steel heat exchanger
|
|
|
+ Direct spark ignition 5:1 continuous electronic modulation for all furnaces
|
|
|
+ 2-stage gas controls 10:1 continuous electronic modulation for furnaces
|
|
|
+ Induced draft venting
|
|
|
+ Terminal block for power and control wiring 200 MBH and larger
|
|
|
+ Automatic high limit safety shut-off Duct thermostat for modulation control
|
|
|
+ Auxiliary manual high limit switch Disconnect switch
|
|
|
+ Combustion air pressure switch Power fusing
|
|
|
+ Air proving switch
|
|
|
+ Accessory:
|
|
|
+ Duct thermostat for 2-stage control
|
|
|
+ Duct thermostat for modulation control
|
|
|
+ Duct curb
|
|
|
+
|
|
|
+FLUE AND COMBUSTION AIR CONFIGURATION
|
|
|
+
|
|
|
+ RT-NO RT-WO Caution: All indirect gas-fired duct furnaces to be installed downstream of the ERV and on the positive side of the
|
|
|
+ (TOP EXHAUST) (FRONT EXHAUST) supply fan.
|
|
|
+
|
|
|
+ FLUE
|
|
|
+ EXHAUST
|
|
|
+
|
|
|
+ AIRFLOW AIRFLOW FLUE AIRFLOW
|
|
|
+ EXHAUST
|
|
|
+
|
|
|
+ AIRFLOW
|
|
|
+
|
|
|
+ COMBUSTION COMBUSTION
|
|
|
+ INTAKE INTAKE
|
|
|
+
|
|
|
+TEMPERATURE RISE AND PRESSURE DROP
|
|
|
+
|
|
|
+ FIGURE 1 GAS FURNACE 50-200 MBH FIGURE 2 GAS FURNACE 250-400 MBH
|
|
|
+
|
|
|
+ Gas Furnace 50 ‐ 200 MBH Gas Furnace 250 ‐ 400 MBH
|
|
|
+
|
|
|
+60 0.32 60 1.6
|
|
|
+
|
|
|
+55 0.28 55 1.4
|
|
|
+
|
|
|
+50 200 50 1.2
|
|
|
+
|
|
|
+ 0.24
|
|
|
+Temperature Rise (deg. F) 400
|
|
|
+ Pressure Drop (inch‐w.c.)
|
|
|
+45 Temperature Rise (deg. F)2001750.2045 400 350
|
|
|
+ Pressure Drop (in.‐w.c.)
|
|
|
+ 175 1.0
|
|
|
+
|
|
|
+40 150 0.16 350 300
|
|
|
+
|
|
|
+ 40 0.8
|
|
|
+
|
|
|
+ 300
|
|
|
+
|
|
|
+35 125 0.12 35 250 250 0.6
|
|
|
+
|
|
|
+ 100
|
|
|
+
|
|
|
+30 75 150 0.08 30 0.4
|
|
|
+
|
|
|
+ 50 125 0.04 25 0.2
|
|
|
+ 100
|
|
|
+25
|
|
|
+ 50/75
|
|
|
+
|
|
|
+20 0.00 20 0.0
|
|
|
+ 7000 2000 9000 10000 11000 12000
|
|
|
+ 0 1000 2000 3000 4000 5000 6000 3000 4000 5000 6000 7000 8000
|
|
|
+ Airflow (CFM)
|
|
|
+ Airflow (CFM)
|
|
|
+Specifications may be subject to change without notice.
|
|
|
+
|
|
|
+38 RENEWAIRE.COM 1.800.627.4499
|
|
|
+DUCT FURNACE DIMENSIONS OPTIONS & ACCESSORIES
|
|
|
+FIGURE 3 RT-NO (TOP EXHAUST OUTDOOR)
|
|
|
+ FIGURE 4 RT-WO (FRONT EXHAUST OUTDOOR)
|
|
|
+
|
|
|
+ FLUE GAS EXHAUST 22.92 FLUE GAS EXHAUST 34.92
|
|
|
+ D (H) COMBUSTION AIR INLET (H)
|
|
|
+
|
|
|
+COMBUSTION AIR INLET 14.89 14.89
|
|
|
+
|
|
|
+ 23.99
|
|
|
+
|
|
|
+ 47.85 23.99
|
|
|
+
|
|
|
+ W (L)
|
|
|
+
|
|
|
+ W 47.85
|
|
|
+
|
|
|
+ (L)
|
|
|
+
|
|
|
+ TABLE 1 OUTDOOR TOP EXHAUST (NO)
|
|
|
+
|
|
|
+ Size Tubes UNLESS OTHERWISE SPECIFIED, 4510 Helgesen Dr. OUTDOOR FRONT EXHAUST (WO)
|
|
|
+ Madison, WI 53718 USA
|
|
|
+LEVEL DESCRIPTION OF REVISION TEL: (608) 221-4499
|
|
|
+ FAX: (608) 221-2824
|
|
|
+
|
|
|
+ TOLL FREE: (800) 627-4499
|
|
|
+ DIMENSIONS ARE IN INCHES. RenewAire LLC
|
|
|
+ TOLERANCES:
|
|
|
+ LINEAR 0.015 MHiDnG/M-4ax00T-eMm-pNerGatAuSreHREiAseTEtRhrOouUgThDFOuOrnRace (°F) TITLE: Vent Locations UNLESS OTHERWISE SPECIFIED,
|
|
|
+ HOLE SIZE 0.005 DIMENSIONS ARE IN INCHES. 4510 Helgesen Dr.
|
|
|
+ ANGULARITY 3 RenewAire LLC TOLERANCES: Madison, WI 53718 USA
|
|
|
+ SURFACE FINISH = LINEAR 0.015
|
|
|
+ Output63 MICROINCH MINIMUM Unit Shipping HOLE SIZE 0.005 TEL: (608) 221-4499
|
|
|
+ Input Rate FAX: (608) 221-2824
|
|
|
+ RT-NO, RT-WO RT-NO RT-WO Diameter ANGULARITY 3 TOLL FREE: (800) 627-4499
|
|
|
+ SURFACE FINISH =
|
|
|
+ - MATERIAL: DRAWN BY: DATE: DWG. NO. FRONT EXHAUWSTeiOghUtTDOWOeRig(hWt O) 63 MICROINCH MINIMUMTITLE:
|
|
|
+ 25 30 35 DO NOT SCALE DRAWING.
|
|
|
+ CAH 40SK475405A 50
|
|
|
+ REMOVE ALL BURRS, BREAK
|
|
|
+ SHARP EDGES.
|
|
|
+ APPLICABLE STANDARDS: DIM.
|
|
|
+ AND TOL. ANSI Y14.5
|
|
|
+ 20 10/19/16 55 60
|
|
|
+
|
|
|
+ FINISH: CHECKED BY: DATE: "W" "L" "H" MATERIAL: "H" "D" DO NOT SCALE DRAWING. DRAWN BY: DATE: DWG. NO.
|
|
|
+ REMOVE ALL BURRS, BREAK DATE:
|
|
|
+ DATE BY -- -- SCALE:1:16 SIZE A SHEET 1 OF 1 HDG-400-M-W
|
|
|
+
|
|
|
+ SHARP EDGES.
|
|
|
+ APPLICABLE STANDARDS: DIM. CHECKED BY:
|
|
|
+ FINISH: AND TOL. ANSI Y14.5 SIZE A SHEET 1 OF 1
|
|
|
+ LEVEL DESCRIPTION OF REVISION DATE SCALE:1:16
|
|
|
+ BY
|
|
|
+ Nom. Duct Opening Airflow (CFM)
|
|
|
+MBH Qty. Btuh Btuh inch inch inch inch inch lb lb
|
|
|
+
|
|
|
+50 3 50,000 40,000 1852 1481 1235 1058 926 823 741 673 617 15.7 127 207
|
|
|
+
|
|
|
+75 3 75,000 60,000 2778 2222 1852 1587 1389 1235 1111 1010 926 15.7 127 207
|
|
|
+
|
|
|
+100 4 100,000 80,000 3704 2963 2469 2116 1852 1646 1481 1347 1235 18.4 142 222
|
|
|
+ 5
|
|
|
+ 169 249
|
|
|
+125 5 125,000 100,000 4630 3704 3086 2646 2315 2058 1852 1684 1543 21.2
|
|
|
+
|
|
|
+150 6 150,000 120,000 5556 4444 3704 3175 2778 2469 2222 2020 1852 23.9 160 240
|
|
|
+
|
|
|
+175 7 175,000 140,000 6481 5185 4321 3704 3241 2881 2593 2357 2160 26.7 47.8 22.9 34.9 180 260
|
|
|
+
|
|
|
+200 8 200,000 160,000 7407 5926 4938 4233 3704 3292 2963 2694 2469 29.4 196 276
|
|
|
+
|
|
|
+250 10 250,000 200,000 9259 7407 6173 5291 4630 4115 3704 3367 3086 34.9 245 325
|
|
|
+
|
|
|
+300 12 300,000 240,000 11111 8889 7407 6349 5556 4938 4444 4040 3704 40.4 6 279 384
|
|
|
+
|
|
|
+350 14 350,000 280,000 12963 10370 8642 7407 6481 5761 5185 4714 4321 45.9 324 429
|
|
|
+
|
|
|
+400 15 400,000 320,000 14815 11852 9877 8466 7407 6584 5926 5387 4938 48.7 394 499
|
|
|
+
|
|
|
+Note: For a single furnace, 20° F minimum temperature rise, 60° F maximum temperature rise.
|
|
|
+
|
|
|
+INDIRECT GAS-FIRED DUCT FURNACE DIMENSIONS
|
|
|
+
|
|
|
+ NOTES
|
|
|
+ 1. UNLESS OTHERWISE SPECIFIED,
|
|
|
+
|
|
|
+ DIMENSIONS ARE ROUNDED TO THE
|
|
|
+ NEAREST EIGHTH OF AN INCH.
|
|
|
+ 2. SPECIFICATIONS SUBJECT TO
|
|
|
+ CHANGE WITHOUT NOTICE.
|
|
|
+
|
|
|
+ 36"
|
|
|
+ Service Area
|
|
|
+
|
|
|
+ TOP VIEW 47 7/8"
|
|
|
+ Case
|
|
|
+
|
|
|
+ 14 7/8" Case 14 7/8"
|
|
|
+Opening Opening
|
|
|
+ 37" (WO) Shown
|
|
|
+6 1/8" 6 1/8"
|
|
|
+ View Port 25" (NO)
|
|
|
+
|
|
|
+ 24" 3/8" Condensate 24"
|
|
|
+ Opening Power Wiring and Drain Tube Opening
|
|
|
+
|
|
|
+ 3" Control Wiring 3/4" Gas Connection 3"
|
|
|
+ LEFT VIEW Inlet Fittings FRONT VIEW
|
|
|
+ RIGHT VIEW
|
|
|
+
|
|
|
+ UNLESS OTHERWISE SPECIFIED, RenewAire LLC Specifications may be subject to change without 4510 Helgesen Dr. notice.
|
|
|
+ DIMENSIONS ARE IN INCHES. Madison, WI 53718 USA
|
|
|
+ TOLERANCES: TEL: (608) 221-4499
|
|
|
+ FAX: (608) 221-2824
|
|
|
+ TOLL FREE: (800) 627-4499
|
|
|
+ LINEAR 0.015
|
|
|
+ FRONT EXHAUST OUTDOOR (WO) DIM SPEC HOLE SIZE 0.005
|
|
|
+ 39
|
|
|
+ ANGULARITY 3
|
|
|
+ FOTIRTLET:HE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM
|
|
|
+
|
|
|
+ SURFACE FINISH =
|
|
|
+ 63 MICROINCH MINIMUM
|
|
|
+
|
|
|
+ DRAWN BY: DATE: DWG. NO.
|
|
|
+CERTIFICATIONS & PERFORMANCE
|
|
|
+
|
|
|
+AHRI 1060
|
|
|
+
|
|
|
+CERTIFIED PERFORMANCE
|
|
|
+
|
|
|
+Energy recovery component certified in accordance with AHRI Standard 1060-2013.
|
|
|
+Actual performance in packaged equipment may vary.
|
|
|
+
|
|
|
+ AHRI-1060 Certified Performance - Model Number L125-G5
|
|
|
+
|
|
|
+ Type Tilt Angle Nominal Airflow Pressure Drop
|
|
|
+ Plate N/A
|
|
|
+ 100% - 750 SCFM 0.65 in. H20
|
|
|
+ Leakage Ratings 75% - 563 SCFM
|
|
|
+
|
|
|
+ Thermal Effectiveness Ratings at 0" Pressure Differential
|
|
|
+
|
|
|
+ Pressure EATR OACF Purge Angle or Nominal Airflow Sensible Latent Total Net Net Net Net
|
|
|
+Differential Setting Airflow Sensible Latent Total
|
|
|
+-1 in. H20
|
|
|
+ 1.0% 1.00 N/A 750 Heating 70% 52% 64% 750 70% 52% 64%
|
|
|
+ 0 in. H20
|
|
|
+ CFM Cooling 70% 42% 53% CFM 70% 42% 53%
|
|
|
+ 1 in. H20
|
|
|
+ 0.0% 1.02 N/A
|
|
|
+
|
|
|
+ 563 Heating 74% 59% 69% 563 74% 59% 69%
|
|
|
+
|
|
|
+ 0.0% 1.05 N/A CFM Cooling 74% 49% 58% CFM 74% 49% 58%
|
|
|
+
|
|
|
+NOTE: SCFM = Standard Cubic Feet per Minute OACF = Outdoor Air Correction Factor EATR = Exhaust Air Transfer Ratio N/A = Not Applicable
|
|
|
+
|
|
|
+40 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ ORDERING & SUPPORT
|
|
|
+
|
|
|
+ LE SERIES MODEL
|
|
|
+ CONFIGURATION GUIDE
|
|
|
+
|
|
|
+ Note: Not all options are available on every model.
|
|
|
+
|
|
|
+MODEL NUMBER J --
|
|
|
+
|
|
|
+DIGIT NUMBER 123 4 567 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
|
|
|
+
|
|
|
+Digits 1 - 5: Model Digit 18: Flow Control
|
|
|
+"LE-6X"
|
|
|
+"LE-8X" "-" = No Isolation Dampers
|
|
|
+"LE10X" "D" = Motorized Damper both Airstreams
|
|
|
+ "E" = Motorized Damper EA or RA Airstream
|
|
|
+ "F" = Motorized Damper FA or OA Airstream
|
|
|
+
|
|
|
+ Digits 7 - 8: Location Digit 19: Unit Control (see Restrictions 6 & 7)
|
|
|
+"IN" = Indoor
|
|
|
+"RT" = Rooftop "A" = Standard Unit Control Wiring
|
|
|
+ "V" = Onboard VFD Both Airstreams
|
|
|
+Digit 9: Orientation "F" = Onboard VFD FA Airstream
|
|
|
+ "E" = Onboard VFD EA Airstream
|
|
|
+"V", "H" (Indoor Units)
|
|
|
+"V", "H", "R", "F" (Rooftop Units) Unit Fusing
|
|
|
+
|
|
|
+ Digit 20:
|
|
|
+
|
|
|
+Digit 10: Vibration Isolation "N" = Non-Fused (Standard)
|
|
|
+ "F" = Fused
|
|
|
+"N" = Neoprene Isolators
|
|
|
+"S" = Spring Isolators Unit Control Enhancements
|
|
|
+
|
|
|
+ Digit 21:
|
|
|
+
|
|
|
+ Digit 11: Wall Type "T" = Transformer with Isolation Relay (Standard)
|
|
|
+"S" = Single "1" = Enhanced Controls
|
|
|
+"D" = Double "2" = Premium Controls
|
|
|
+ "3" = Enhanced Controls with BACNET License
|
|
|
+Digit 12: Phase (see Restriction 2) "4" = Premium Controls with BACNET License
|
|
|
+
|
|
|
+"1" = Single Phase Digit 22: Filter Options (see Restriction 8)
|
|
|
+"3" = Three Phase
|
|
|
+ "-" = None
|
|
|
+Digit 13: Voltage (see Restriction 1) "F" = Filter Monitor Both Airstreams
|
|
|
+
|
|
|
+"4" = 460V Digit 23: Flexible Packaging
|
|
|
+"5" = 208-230V
|
|
|
+"8" = 575V "A" = Assembled (single piece flat bed)
|
|
|
+ "M" = Modular (two pieces for enclosed trailer)
|
|
|
+
|
|
|
+Digit 14: FA Horsepower (see Restrictions 2, 3 & 4)
|
|
|
+
|
|
|
+"D" = 3 HP Low Speed Digit 24: Paint and Customization
|
|
|
+"F" = 3 HP Medium Speed
|
|
|
+"G" = 3 HP High Speed "-" = None
|
|
|
+"J" = 5 HP Low Speed "W" = White Paint
|
|
|
+"K" = 5 HP Medium Speed "C" = Custom Paint
|
|
|
+"L" = 5 HP High Speed "X" = Custom Unit
|
|
|
+"M" = 7.5 HP Low Speed
|
|
|
+"N" = 7.5 HP Medium Speed Digit 25: Safety Listing (see Restriction 5)
|
|
|
+"P" = 7.5 HP High Speed
|
|
|
+"Q" = 10 HP Medium Speed "L" = Listed
|
|
|
+"R" = 10 HP High Speed "N" = Non-Listed
|
|
|
+
|
|
|
+Digit 15: EA Horsepower (see Restrictions 2, 3 & 4)
|
|
|
+
|
|
|
+"D" = 3 HP Low Speed
|
|
|
+"F" = 3 HP Medium Speed
|
|
|
+"G" = 3 HP High Speed
|
|
|
+"J" = 5 HP Low Speed
|
|
|
+"K" = 5 HP Medium Speed
|
|
|
+"L" = 5 HP High Speed
|
|
|
+"M" = 7.5 HP Low Speed
|
|
|
+"N" = 7.5 HP Medium Speed
|
|
|
+"P" = 7.5 HP High Speed
|
|
|
+"Q" = 10 HP Medium Speed
|
|
|
+"R" = 10 HP High Speed
|
|
|
+
|
|
|
+*NOTES: Digits 16 and 17 are not used in these models.
|
|
|
+Digit 6 "J" = G5 Core Type
|
|
|
+
|
|
|
+Restrictions:
|
|
|
+ 1: Voltage Codes "4" & "8" only available with Phase Code "3" (Three-Phase).
|
|
|
+ 2: Phase Code "1" only available in Motor Codes "D", "F" & "G".
|
|
|
+ 3: Motor Code "P" (7.5 HP High Speed) not available in LE-6X.
|
|
|
+ 4: Motor Codes "Q" and "R" (all 10 HP Speeds) not available in LE-6X & LE-8X.
|
|
|
+ 5: Some units with Customization Code "X" are not safety listed.
|
|
|
+ 6: Unit Control Codes "V", "E" & "F" only available with Motor Codes "G", "L" & "N" in LE-6X.
|
|
|
+ 7: Unit Control Codes "V", "E" & "F" only available with Motor Codes "G", "L", "P" & "R" in LE-8X & LE-10X.
|
|
|
+ 8: Filter Code "F" not available with Unit Control Enhancements Codes "1", "2", "3" & "4". Filter Monitor is provided with those options.
|
|
|
+
|
|
|
+ For Technical SupLpEortMEO-mDEaiLl:SRenewaireSupport@renewaire.com
|
|
|
+ CToOMPlaMcEeRaCnIOArLdePrREO-mDaUilC: RTeCneOwDaEireCOHrAdeRrsT@renewaire.com
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 41
|
|
|
+ORDERING & SUPPORT
|
|
|
+
|
|
|
+ EK SERIES ELECTRIC DUCT HEATER
|
|
|
+ CONFIGURATION GUIDE
|
|
|
+
|
|
|
+ Note: Not all options are available on every model.
|
|
|
+
|
|
|
+MODEL NUMBER -
|
|
|
+
|
|
|
+DIGIT NUMBER 123 4 567 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
|
|
|
+
|
|
|
+Digits 1 - 2: Heater Type Digit 18: Voltage (see Restrictions 7 & 8)
|
|
|
+"EK "= Electric Heater (Standard) "1" = 120V
|
|
|
+ "2" = 208V
|
|
|
+ Digits 4 - 5: Width in Inches (see Restriction 1) "3" = 240V
|
|
|
+08-99 "4" = 480V
|
|
|
+ "8" = 600V
|
|
|
+ "9" = 277V
|
|
|
+
|
|
|
+ Digits 6 - 7: Height in Inches (see Restriction 2) Digit 19: Phase
|
|
|
+08-99
|
|
|
+ "1" = Single-Phase
|
|
|
+ Digits 8 - 10: Capacity in kW (see Restrictions 3, 4 & 5) "3" = Three-Phase
|
|
|
+001-175
|
|
|
+ Digit 20: Power Fusing (see Restriction 9)
|
|
|
+ "-" = None
|
|
|
+Digit 11: Mount "F" = Fusing
|
|
|
+
|
|
|
+"S" = Slip In (Standard) Digit 21: Stage
|
|
|
+"F = Flanged
|
|
|
+
|
|
|
+Digit 12: Element Style "1" = Single (Standard)
|
|
|
+ "2" = 2-Stage
|
|
|
+"C" = Open Coil (Standard) "4" = 4-Stage
|
|
|
+
|
|
|
+Digit 13: Element Material Digit 22: Control Voltage
|
|
|
+
|
|
|
+"C" = 60-20-20 Ni-Cr-Fe with Nickel Plate Terminal Pins (Standard) "S" = 24VAC
|
|
|
+"A" = 80-20 Ni-Cr with Stainless Steel Terminal Pins
|
|
|
+
|
|
|
+Digit 14: Airflow Orientation Digit 23: Control Type (see Restrictions 10, 11 & 12)
|
|
|
+
|
|
|
+"H" = Horizontal (Standard) "D" = Duct Thermostat with Sensor (Standard)
|
|
|
+"V" = Vertical "E" = Electronic Step Control with Sensor
|
|
|
+ "S" = SCR (For BAS System)
|
|
|
+Digit 15: Control Box Offset "V" = SCR with Analog Sensor (0-10Vdc)
|
|
|
+
|
|
|
+"L" = Left Hand (Standard) Digit 24: Time Delay
|
|
|
+"R" = Right Hand
|
|
|
+
|
|
|
+ "-" = None (Standard)
|
|
|
+
|
|
|
+Digit 16: Control Box Recessed
|
|
|
+
|
|
|
+"-" = None (Standard) Digit 25: Pilot Light
|
|
|
+"R" = Recessed 1"
|
|
|
+ "N" = None (Standard)
|
|
|
+Digit 17: Control Box Dust Tight "L" = Light
|
|
|
+
|
|
|
+"-" = None (Standard)
|
|
|
+"D" = Dust Tight
|
|
|
+
|
|
|
+*NOTES:
|
|
|
+Digit 3 is not used in this model.
|
|
|
+All heaters come with standard features: Disconnect Switch, Air Flow Switch (non adjustable), Control Transformer
|
|
|
+Descriptions of feature and options are found in the installation and operation manual.
|
|
|
+
|
|
|
+Restrictions:
|
|
|
+
|
|
|
+1: Width inches entered as a whole number.
|
|
|
+2: Height inches entered as a whole number.
|
|
|
+3: Heater density should be less than 30kW/ft². DENSITY= HEATER CAPACITY (kW) < 30
|
|
|
+ (W" x H")/144
|
|
|
+4: Heater capacity kW entered as a whole number.
|
|
|
+5: Formulas for calculating kW and temperature rise: kW = CFM x ΔT ΔT = kW x 3150
|
|
|
+ 3150 CFM
|
|
|
+7: Voltage Codes "1" & "9" only available with Phase Code "1" (Single-Phase).
|
|
|
+8: Voltage Codes "4" & "8" only available with Phase Code "3" (Three-Phase).
|
|
|
+9: Power Fusing Code "F" required when amperage is >48A. (based on kW and voltage)
|
|
|
+10: Control Type Code "D" only available with Stage Code "1" & "2".
|
|
|
+11: Control Type Code "E" only available with Stage Code "4".
|
|
|
+12: Control Type Code "S" & "V" only available with Stage Code "1", unless amperage is greater than or equal to 96A, then Stage Code "4" is automatically selected.
|
|
|
+
|
|
|
+ For TechnicEalLSEupCpoTrtREI-CmaPil:OReSnTewHairEeSAuTpport@renewaire.com
|
|
|
+ ToCPOlacNeFanIGOUrdeRr AE-TmIaOil:NReCneOwaDireEOrCdeHrsA@RreTnewaire.com
|
|
|
+
|
|
|
+42 RENEWAIRE.COM 1.800.627.4499
|
|
|
+ ORDERING & SUPPORT
|
|
|
+
|
|
|
+GH SERIES INDIRECT GAS-FIRED DUCT
|
|
|
+ FURNACE CONFIGURATION GUIDE
|
|
|
+
|
|
|
+ Note: Not all options are available on every model.
|
|
|
+
|
|
|
+MODEL NUMBER - - --
|
|
|
+
|
|
|
+DIGIT NUMBER 123 4 567 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
|
|
|
+
|
|
|
+Digits 1 - 2: Duct Furnace Type Digit 17: Disconnect Switch
|
|
|
+"GH" = Gas Furnace 50-400 MBH
|
|
|
+ "N" = None (Standard)
|
|
|
+ "D" = Disconnect Switch
|
|
|
+
|
|
|
+ Digits 4 - 5: Location Digit 18: System/Inducer Voltage (see Restriction 2)
|
|
|
+"IN" = Indoor "1" = 115V
|
|
|
+"RT" = Rooftop "2" = 208V
|
|
|
+ "3" = 230V
|
|
|
+ Digits 6 - 7: Vent Location
|
|
|
+"SI" = Separated Top Indoor Digit 19: Phase
|
|
|
+"KI" = Top Exhaust Indoor
|
|
|
+"WO" = Front Exhaust Outdoor "1" = Single Phase
|
|
|
+"NO" = Top Exhaust Outdoor
|
|
|
+ Digit 20: Power Fusing (see Restriction 3)
|
|
|
+ "N" = None
|
|
|
+ Digits 8 - 10: Input Capacity in MBH "F" = Fusing
|
|
|
+"050", "075", "100", "125", "150", "175", "200", "250", "300", "350", "400"
|
|
|
+
|
|
|
+ Fuel Type Digit 22: Control Voltage
|
|
|
+
|
|
|
+Digit 11: "S" = 24VAC
|
|
|
+
|
|
|
+"N" = Natural Gas (Standard) Digit 23: Control Type (see Restriction 1)
|
|
|
+"P" = Propane
|
|
|
+
|
|
|
+Digits 12 - 13: Tube Material "T" = Two Stage High/Low with Thermostat (Standard)
|
|
|
+"SS" = 409 Stainless Steel (Standard) "S" = Single Stage On/Off with Thermostat
|
|
|
+"CS" = 304 Stainless Steel "E" = Modulating 5:1 (Natural Gas)/3:1 (Propane) with Thermostat
|
|
|
+ "W" = Modulating 10:1 (Natural Gas)/6:1 (Propane) with Thermostat
|
|
|
+Digit 14: Airflow Orientation "2" = Two Stage High/Low without Thermostat
|
|
|
+ "1" = Single Stage On/Off without Thermostat
|
|
|
+"H" = Horizontal "M" = Modulating 5:1 (Natural Gas)/3:1 (Propane) without Thermostat
|
|
|
+ "V" = Modulating 10:1 (Natural Gas)/6:1 (Propane) without Thermostat
|
|
|
+ Thermal Efficiency
|
|
|
+ Digit 15:
|
|
|
+"S" = 80%
|
|
|
+
|
|
|
+Digit 16: Elevation
|
|
|
+
|
|
|
+"S" = 0 - 2000' (Standard)
|
|
|
+"2" = 2001'- 3000'
|
|
|
+"3" = 3001' - 4000'
|
|
|
+"4" = 4001' - 5000'
|
|
|
+"5" = 5001' - 6000'
|
|
|
+"6" = 6001' - 7000'
|
|
|
+"Y" = 7001' and above
|
|
|
+
|
|
|
+*NOTE:
|
|
|
+Digits 3, 21, 24 & 25 are not used in this model.
|
|
|
+All heaters come with standard features: Air Proving Switch, Auxiliary High Temperature Limit Switch
|
|
|
+Descriptions of feature and options are found in the installation and operation manual.
|
|
|
+
|
|
|
+Restrictions:
|
|
|
+ 1: Control Type Code "V" & "W" not available with Input Capacity in MBH Codes "050", "075", "100", "125", "150" & "175".
|
|
|
+ 2: System/Inducer Voltage Code "2" not available with Input Capacity in MBH Codes "050", "075", "100", "125" , "150", "175" & "200".
|
|
|
+ 3. Power Fusing Code “F” only available with Disconnect Switch Code “D”. Power Fusing Code “F” always selected when Disconnect Switch Code “D” is selected.
|
|
|
+
|
|
|
+ GAS HEAT CONFIGURATION
|
|
|
+ For Technical SuppCoOrt DE-EmaCil:HRAenRewTaireSupport@renewaire.com
|
|
|
+
|
|
|
+ To Place an Order E-mail: RenewaireOrders@renewaire.com
|
|
|
+
|
|
|
+ FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 43
|
|
|
+ORDERING & SUPPORT
|
|
|
+
|
|
|
+ INDOOR AIR QUALITY MATTERS
|
|
|
+
|
|
|
+ u Deficient IAQ is an EPA top-five health risk
|
|
|
+
|
|
|
+ u People spend 90% of their time indoors
|
|
|
+
|
|
|
+ u Indoor air can be 2-5 times and up to 100 times
|
|
|
+ more polluted than outdoor air
|
|
|
+
|
|
|
+BENEFITS OF INCREASED VENTILATION
|
|
|
+
|
|
|
+ BETTER IMPROVED INCREASED
|
|
|
+ HEALTH COGNITIVE PRODUCTIVITY
|
|
|
+ FUNCTION
|
|
|
+
|
|
|
+TECHNICAL/APPLICATIONS SUPPORT
|
|
|
+The goal of our technical-support team is to provide the BEST CUSTOMER SERVICE
|
|
|
+in the HVAC industry. You can count on our knowledgeable and seasoned staff for all your technical,
|
|
|
+application and service needs, and we’ll respond quickly and effectively to answer any of your questions.
|
|
|
+
|
|
|
+ CONTACT RENEWAIRE
|
|
|
+
|
|
|
+ PHONE: FOR TECHNICAL SUPPORT:
|
|
|
+ 1.800.627.4499 RenewaireSupport@renewaire.com
|
|
|
+
|
|
|
+ FAX: TO PLACE AN ORDER:
|
|
|
+ 608.221.2824 RenewaireOrders@renewaire.com
|
|
|
+
|
|
|
+44 RENEWAIRE.COM 1.800.627.4499
|
|
|
+RELEVANT RENEWAIRE
|
|
|
+
|
|
|
+EVERYWHERE TEMPERS THE AIR
|
|
|
+
|
|
|
+EVERY GEOGRAPHIC REGION Our ERVs moderate the extremes
|
|
|
+Our ERVs function perfectly across the world in every of outdoor supply-air temperature
|
|
|
+geographic region. and humidity year-round, providing
|
|
|
+ a sustainable solution for fresh air
|
|
|
+EVERY CLIMATE that feels like a perfect spring day.
|
|
|
+Our ERVs operate in every climate—from Alaska to
|
|
|
+Florida, and everywhere in between.
|
|
|
+
|
|
|
+EVERY PROJECT
|
|
|
+From massive skyscrapers to cozy residential homes,
|
|
|
+our ERVs can be used in every size project and in every
|
|
|
+code jurisdiction.
|
|
|
+
|
|
|
+APPLIED EVERYWHERE
|
|
|
+
|
|
|
+When indoor occupants breathe in unclean air, this harms their health and causes cognitive impairment. Our ERVs can
|
|
|
+provide cleaner and healthier indoor air for every type of building in the world, thus improving occupants’ wellbeing,
|
|
|
+while also reducing energy costs.
|
|
|
+
|
|
|
+RESIDENTIAL DAYCARE
|
|
|
+The increased airtightness of newer and remodeled Crowded daycare facilities breed deficient IAQ, thus
|
|
|
+homes is causing deficient IAQ, resulting in more health causing health problems for everyone—especially
|
|
|
+problems for indoor occupants. children who are more vulnerable.
|
|
|
+
|
|
|
+COMMERCIAL EDUCATION (LOWER AND HIGHER)
|
|
|
+As commercial buildings become more airtight, With students and teachers packed into tight classrooms,
|
|
|
+deficient IAQ is increasing and causing sickness, instances of deficient IAQ go up, resulting in academic
|
|
|
+absenteeism and decreased productivity. performance and test scores going down.
|
|
|
+
|
|
|
+H E A LT H C A R E GOVERNMENT
|
|
|
+The high occupant density of hospitals, nursing homes Aging and crowded government buildings result in
|
|
|
+and other healthcare facilities results in deficient IAQ deficient IAQ, which can impair worker performance
|
|
|
+and ensuing health problems for patients and staff alike. and productivity.
|
|
|
+
|
|
|
+RESTAURANTS/COFFEE SHOPS EVERY TYPE OF BUILDING
|
|
|
+The large volume of indoor occupants in restaurants Every type of building can benefit from the enhanced
|
|
|
+and coffee shops causes deficient IAQ and subsequent IAQ generated by RenewAire ERVs, including
|
|
|
+health problems. veterinary clinics, nail salons and manufacturing
|
|
|
+ facilities, among others.
|
|
|
+RETAIL
|
|
|
+The high level of foot traffic in retail stores leads
|
|
|
+to deficient IAQ and the potential sickness of shoppers,
|
|
|
+which can negatively impact sales.
|
|
|
+ RENEWAIRE EVERYWHERE LIT115_00 (01/19)
|
|
|
+
|
|
|
+ RenewAire ERVs can be applied everywhere across all
|
|
|
+ commercial, educational, institutional, light industrial
|
|
|
+
|
|
|
+ and residential buildings. Our technology excels in every
|
|
|
+ geographic region, every climate, and every size project.
|
|
|
+
|
|
|
+Member of the S&P Group
|
|
|
+Family of Brands
|
|
|
+
|