JeanBenitez 1 vuosi sitten
vanhempi
commit
5fa942b625

+ 880 - 0
media/documents/pdf/CatalogoCorporativo.pdf

@@ -0,0 +1,880 @@
+Soler&Palau
+
+                          Ventilation Group
+Hemos creído en el proyecto y lo hemos hecho
+realidad. Y la realidad ha traspasado fronteras
+y nos hemos convertido en un equipo. Hemos
+demostrado que son las personas, su actitud y
+su conocimiento, quienes construyen el futuro.
+
+A project we believed in which we have now
+made a reality. This reality has crossed over
+borders and we have become a team proving
+that people, their attitude and knowledge are
+the elements that build the future.
+                                                                        José Palau Mallol                                      BOARD OF DIRECTORS
+                                                                        Chairman Soler & Palau Ventilation Group
+                                                                                                                               Hilario Tomé          José Palau Mallol
+
+                                                                                                                               Group Managing Director Chairman
+
+                                                                                                                               Carlos Campderrós     Blanca Palau Mallol
+                                                                                                                               Financial Director    Non Executive Director
+
+   La filosofía de Soler & Palau a los largo de su existencia ha sido Over the years Soler & Palau philosophy has been to      La estrategia corporativa especifica cómo queremos               Our corporate strategy defines both how we aim to
+                                                                                                                               posicionarnos en el mercado y el camino a seguir para            position the company in the market and the path to follow
+   focalizarse continuamente en satisfacer las necesidades de sus focus constantly in meeting our customers’ needs. We         alcanzar los objetivos sin dejar de lado los valores de nuestra  to achieve this objective without compromising the values
+                                                                                                                               cultura empresarial. Apoyados en los pilares del Trabajo en      of our business culture. Based on the foundations of
+   clientes. Siempre hemos estado convencidos de que, solamente have always been convinced that only offering solutions        Equipo, Proximidad y Respeto a la Diversidad individual,         Teamwork, Proximity and a Respect for personal diversity,
+                                                                                                                               hemos proyectado nuestra empresa para estar presentes            we have positioned the company on an international level
+   ofreciendo soluciones que aporten más valor a nuestros clientes that create more value to our customers we will keep a      internacionalmente aplicando políticas locales bajo el           but at the same time applying local policies under the
+                                                                                                                               paraguas de una filosofía global.                                umbrella of a global philosophy.
+   que las de nuestros competidores, podremos mantener una leadership position in the world market of energy efficient
+
+   posición de liderazgo en el mercado mundial de sistemas de ventilation systems for Residential and no Residential
+
+   ventilación eficientes energéticamente tanto para edificios Buildings, Industrial Applications and Infrastructures
+
+   residenciales y no residenciales, como en aplicaciones industriales
+
+   e Infraestructuras.                                                  We tr y to stay ver y close to our customers wherever
+
+   Allá donde se encuentren nuestros clientes queremos que they are and this is why we have set up a vast network              La solidez de los resultados nos permite autofinanciarnos The strength of our business results have provided us
+
+   nos sientan como una empresa cercana y por ello hemos of companies spanning through the whole world able to                 e invertir de forma constante para ser pioneros en la with a self-financing capacity. This position enables us to
+
+   establecido un gran número de empresas filiales a lo largo adapt our innovative ventilation solutions to the local          investigación, el desarrollo y la innovación. Nos anticipamos continue our investment across all areas of the business
+
+   del mundo, capaces de adaptar soluciones innovadoras de market needs.                                                       a las necesidades de un mercado en constante evolución, and to become pioneers in research, development
+
+   ventilación a las necesidades locales específicas.                                                                          incorporando a nuestro catálogo nuevos productos y soluciones and innovation. We anticipate the needs of a market
+
+2  Los empleados son el activo más importante de la Empresa. Our people are our greatest asset. It is only with the            de ventilación, basadas en la eficiencia y el ahorro energético. incorporating new products and ventilation solutions         3
+
+   Solamente con la dedicación y compromiso de ellos podemos determination and dedication of our people that we can reach                                                                       into our catalogue based on air movement efficiency and
+
+   alcanzar el nivel de servicio que nuestros clientes merecen. the level of service that our customers deserve.               Un equipo humano altamente motivado, autoexigente y energy saving.
+
+                                                                                                                               honesto, pone todo su empeño en lograr un elevado nivel de
+
+   José Palau Mallol                                                                                                           calidad en los productos y en proporcionar el mejor servicio A highly motivated, skilled and honest workforce devote
+   Chairman
+                                                                                                                               a nuestros clientes.                                             their efforts into delivering only the highest standards of
+
+                                                                                                                                                                                                product quality and service to our customers.
+
+                                                                                                                               Trabajamos día a día para conservar nuestros valores y nos
+
+                                                                                                                               esforzamos para mejorar en formación y conocimientos con We continually strive to preser ve our values and improve
+
+                                                                                                                               el objetivo de consolidar nuestro liderazgo en el mercado training and knowledge, with the aim of strenghtening our
+
+                                                                                                                               de ventilación y fortalecer las relaciones con clientes leadership in the ventilation market and relationship with
+
+   Tenemos claro cuales son nuestros                                                                                           y colaboradores.                                                 our customers and partners.
+   valores y fortalezas, pero son las
+   personas que conforman el Grupo                                                                                             Board of Directors
+   quienes dan plena validez.
+                                                                                                                                                                                                Un crecimiento constante y ordenado
+   We are sure about our values and                                                                                                                                                             con el compromiso de nuestro
+   strengths, but the people in the Group                                                                                                                                                       equipo humano.
+   are what gives it full meaning.
+                                                                                                                                                                                                Continuous controlled growth with
+                                                                                                                                                                                                the commitment of our workforce.
+                                                                 INTERNATIONAL COMMITEE           C.F. Yang                               MANAGEMENT                        Hilario Tomé
+                                                                                                  Chairman Kruger                                                           Group Managing Director
+                                                                 J. Palau Mallol                                                          Juan Manuel Lecue
+                                                                 Chairman                         Hilario Tomé                            European Managing Director        Chen Hong
+                                                                 Soler & Palau Ventilation Group  Managing Director                                                         Asia Managing Director
+                                                                                                  Soler & Palau Ventilation Group         Eugene Scotcher
+                                                                 J.M. Cuatrecasas                                                         North American Managing Director  Mikel Cuatrecasas
+                                                                 President S&P Mexico                                                                                       Latin America Managing Director
+                                                                                                                                          Carlos Campderrós
+                                                                                                                                          Group Financial Director
+
+En los últimos años Soler & Palau Ventilation Group , gracias a  La fuerte cultura corporativa de Soler & Palau Ventilation               In the last few years Soler & Palau Ventilation Group, Soler & Palau Ventilation Group has a strong corporate
+la confianza de sus clientes y al talento de sus empleados, se   Group, de la que emanan valores compartidos por todos sus
+ha convertido en un líder global en el suministro de sistemas    miembros, determina la personalidad de nuestro Grupo y es                thanks to the confidence of its customers and the talent of culture, with values that are shared by the entire
+de ventilación eficientes energéticamente.                       el elemento principal de cohesión entre todos nosotros.
+                                                                                                                                          its employees, has become a global leader in the supply workforce. This culture determines the personality of
+
+                                                                                                                                          of energy-efficient ventilation systems.                           our Group and it is the main cohesive element between
+
+                                                                                                                                                                                                             its members.
+
+             Nuestra actividad siempre se ha basado en el reforzamiento En Soler & Palau Ventilation Group siempre hemos                  Our work has always been based on the continuous
+             continuo del compromiso con los clientes trabajando considerado la diversidad individual de los miembros del
+             conjuntamente en la solución de sus problemas, anticipándonos Grupo como una fortaleza y un valor enriquecedor, pues         reinforcement of commitment to our customers, working Soler & Palau Ventilation Group has always considered
+             a sus necesidades y manteniendo un alto grado de fiabilidad en creemos que esta diversidad refuerza el conjunto a través de
+             nuestras propuestas de valor. Para conseguirlo estamos cerca las diferentes formas de ser y de hacer.                        together to solve their problems, anticipating their needs the diversity of its workforce as a strength and a
+             de ellos a través de un gran número de filiales, localizadas a lo
+             largo de los cinco continentes, las cuales cuentan con personal                                                              and continuing to improve our value proposals. To achieve positive value. We believe that diversity reinforces the
+             altamente cualificado y especialmente formado en productos y
+             sistemas de ventilación.                                                                                                     this we keep close to our customers through a substantial company as a whole with different personalities, ideas
+4
+             Geográficamente Soler & Palau Ventilation Group está                                                                         network of companies on all five continents. Each of our and perspectives.
+             segmentado en cuatro regiones: Europa, Asia, Latino- américa
+             y Norteamérica. Al frente de cada una de ellas hay un Director                                                               companies include highly qualified personnel specially
+             General con plena responsabilidad sobre los resultados de la
+             actividad de las mismas.                                                                                                     trained in the design and application ventilation products
+
+                                                                                                                                          for air movement systems.
+                                                                                                                                                                                                                                                                                                      5
+
+                                                                                                                                          Geographically Soler & Palau Ventilation Group is divided
+
+                                                                                                                                          into four regions, Europe, Asia, Latin America and North
+
+                                                                                                                                          America; each region has a Managing Director who is fully
+
+                                                                                                                                          responsible for the results of the activities in their region.
+
+Un proyecto global                                                                                                                        Soler&Palau
+con una filosofía local.
+                                                                                                                                                                    Ventilation Group
+A global project
+with a local philosophy.
+                                                                                                                                     EUROPEAN EXECUTIVE COMMITTEE
+
+                                                                                                                                     Marius Gamissans                              Philip Revy
+                                                                                                                                     R+D Director                                  Product Marketing Director
+
+                                                                                                                                     Ramón Gracia                                  Pere García
+
+                                                                                                                                     Manufacturing Director Supply Chain Director
+
+A selection of some of the Soler & Palau manufacturing locations.                                                                    Juan Manuel Lecue                             Xavier Forrellat
+                                                                                                                                     Managing Director                             Human Resources Director
+
+                                                                                                                                                                                       ASIAN EXECUTIVE COMMITTEE
+
+                                                                                                                                                                                       David Tang              Antony Yen
+                                                                                                                                                                                       General Manager         Technical & Commercial director
+
+                                                                                                                                                                                       Chen Hong               C J Wang
+                                                                                                                                                                                       Managing Director       Financial Controller
+
+Beijing Kruger (China)                                             Malasia Kruger  Singapur Kruger
+
+                                                                                                                  Soler & Palau Ventilation Group around                                                          Un Grupo sólido
+                                                                                                                  the world                                                                                       presente en todo el mundo.
+
+                                                                                                                                                                                                                  A solid Group
+                                                                                                                                                                                                                  with worldwide presence.
+
+                                                                                                                  Europe                                                                        Asia
+
+                                                                                                                  Plantas productivas / Production plants:                                      Plantas productivas / Production plants:
+
+                                                          Brasil   Mexico          Madrid (Spain)                 Spain ( 4), France (1), England (1), Norway (1).                              Singapore (1), China (4), Thailand (1), Malaysia (1), India (1),
+
+6                                                                                                                 Filiales Comerciales / Commercial Subsidiaries:                               Vietnam (1).
+
+                                                  Soudan (France)                                                 Spain, Portugal, France, UK, Belgium, Netherlands, Germany, Filiales Comerciales / Commercial Subsidiaries:
+
+                                                                                                                  Italy, Switzerland, Austria, Romania, Latvia, Russia, Czech Hong Kong, Guangzhou, Wuhan, Beijing, Shangai, India (2),                               7
+
+                                                                                                                  Republic, Norway, Ukrania, Ireland.                                           Indonesia, Malaisia, Singapore, Thailand, Taiwan, Philippines,
+
+                                                                                                                                                                                                Vietnam. Australia: Sidney.
+
+                                                                                                                  America                                                                       Una amplia Red de Distribuidores exclusivos en todo el mundo,
+                                                                                                                  Plantas productivas / Production plants:                                      con presencia en mas de 80 países..
+                                                                                                                  USA (2), Mexico (1), Brazil (1).                                              An extensive global network of exclusive independent
+                                                                                                                  Filiales Comerciales / Commercial Subsidiaries:                               distributors covering more than 80 countries.
+                                                                                                                  Mexico, USA, Canada, Guatemala, Colombia, Chile.
+
+                                                                   Norway          Ripoll - Main Factory (Spain)
+
+                                                                                                                                                                                       650
+
+                                                                                                                                                                              502
+
+                                                                                                                          Million €                                358
+
+                                                                                                                                                              240
+                                                                                                                          9 30 56 85 146
+
+Guangzhou Kruger                                                   Shangai Kruger  Sils (Spain)                   1980
+                                                                                                                         1985
+                                                                                                                                 1990                                         Ob.2016
+                                                                                                                                        1995
+                                                                                                                                               2000
+                                                                                                                                                        2005
+                                                                                                                                                               2010
+                                                                                                                                                                        2013
+
+                                                                                                                                                                                                               People: 4.100                    Builds: 280.000 Sq/m
+   Torelló (Spain)                          Florida (USA)
+
+   Thailand Kruger                          Wisconsin - RenewAire (USA)
+
+8                                                                                                 9
+
+   India Kruger                             Wuhan Kruger
+
+                                                                         Countries with presence
+                                                                         of S&PVG
+
+                                                                         Factories
+                                                                         R+D+I Centres
+                                                                         Assembly Facilities
+                                                                         Subsidiaries
+                                                                         Distributors
+
+   Harrogate - Envirovent (United Kingdom)  Philippines Kruger
+GROUP SUPPORT FUNCTIONS                                                                                                                                                           FRANCE UNELVENT                               Back:
+                                                                                                                                                                                  Front:
+Javier Gaudes            Mikel Sampedro                                                                                                                                                                Alain Ferrari            Damien Michel
+                                                                                                                                                                                  Philippe Fonteneau   Logistics Director       Prescription Manager
+Information Systems Director Marketing Communication Director                                                                                                                     Area Manager
+                                                                                                                                                                                                       Aurélie Munoz            Cédric Boxede
+Marc Valles              Joan Vila                                                                                                                                                Patrick Adolphe      Marketing Communication  Technical Director
+Quality Director         Group Controller                                                                                                                                         Commercial Director
+                                                                                                                                                                                                                                Thierry Desmarais
+                                                                                                                                                                                  Thierry Homo                                  Area Manager
+                                                                                                                                                                                  Managing Director
+                                                                                                                                                                                                                                Philippe Ribat
+                                                                                                                                                                                  Marie-Claude Sarda                            Area Manager
+                                                                                                                                                                                  Assistant Director
+
+                                                               SPAIN EXPORT DEPARTMENT          Back:                 Jordi Canet         CHINA SHANGHAI                                 J G Xiong
+                                                                                                                      Area Sales Manager                                                 General Manager
+                                                               Front:                           Joan Geli Stenhammar                      Chen Hui
+                                                                                                Area Sales Manager                        Sales Manager                                  Xu Juan
+                                                               Vincent Duquenne                                                                                                          Finance Manager
+                                                               Area Sales Manager               Alex Maymó                                Chen Yue
+                                                                                                CFD Engineer                              Marketing Manager
+                                                               Joan Miró
+                                                               Export Director                  Ingrid Castellón                          S H Xu
+                                                                                                Area Sales Manager                        Executive Director
+                                                               Josep Corbera
+                                                               International Logistics Manager
+
+El factor humano, clave del éxito.                             • Inculcar a nuestros mandos la delegación de                              The human factor, key to success.
+                                                                 responsabilidades y el respeto por el individuo
+El camino realizado hasta hoy, no ha sido fácil. En Soler &      (Empowerment).                                                           The journey up to now has not been easy. Soler & Palau
+Palau Ventilation Group hemos primado siempre el trabajo en                                                                               Ventilation Group has always given precedence to
+equipo, la formación y la promoción interna.                   • Gestionar activamente la aportación y transmisión de                     teamwork, training and internal promotion.
+                                                                 ideas y proyectos entre las diferentes unidades de negocio
+Habiendo entrado ya en la segunda década del Siglo               del Grupo (Best Practices).                                              Having entered the second decade of the 21st centur y,
+XXI, desarrollando y mejorando herramientas de gestión                                                                                    developing and improving management tools (performance
+(evaluación del desempeño, formación continua,                 • Lograr, utilizando como palanca principal el ejemplo, la                 evaluation, continuous training, interdepartmental
+comunicación interdepartamental, código de conducta              identificación de todos los componentes del equipo con los               communication and internal codes of conduct) we strive
+interno, etc.) queremos consolidar en el futuro inmediato los    valores de la empresa y su implicación en el desarrollo de               to achieve the following goals in the future:
+siguientes objetivos:                                            la visión y misión de nuestro proyecto empresarial.
+
+                                                               • Detectar, promocionar y retener el talento.
+
+10                                                                                                                                        • Cultivate a respect for the individual through the                                                        11
+
+         Humildad, austeridad, transparencia.                                                                                             delegation of responsibilities (Empowerment).
+         Humility, transparency, frugal use
+         of company resources..                                                                                                           • Actively manage the contribution and transmission
+                                                                                                                                            of ideas between the Group’s different business units
+                                                                                                                                            (Best Practices).
+
+                                                                                                                                          • Promote achievement through the alignment of our
+                                                                                                                                            corporate values with each individuals involvement
+                                                                                                                                            in the development of the vision and mission of our
+                                                                                                                                            business project.
+
+                                                                                                                                          • Identify, promote and retain talent.
+    USA                      Eugene Scotcher                                                                                                                                                                    PHILIPPINES
+                             CEO S&P North America
+    Greg Johnson                                                                                                                                                                                                S. B. Esmenda
+    Manufacturing Director   Joshua Lynch                                                                                                                                                                       General Manager
+                             Engineering Manager
+    Deborah Forsberg                                                                                                                                                                                            R. H. Aguilar
+    Chief Operating Officer                                                                                                                                                                                     Asst. Marketing Manager
+
+    Robert Robinson                                                                                                                                                                                             R. G. De Guzman
+    VP of Sales & Marketing                                                                                                                                                                                     Chief Accountant
+
+                                          GERMANY PLUGGIT             Markus Lang                                                                    BELGIUM
+                                                                      Product Director
+                                          Dieter Frost                                                                                               Marc Leroy
+                                          Marketing Director          Christian Bolsmann                                                             Flanders Commercial Manager
+                                                                      Managing Director
+                                          Otto Greipel                                                                                               Alain Birenbaum
+                                          Sales Director                                                                                             Managing Director
+
+                                                                                                                                                     Patrick Aerts
+                                                                                                                                                     Wallonia Commercial Manager
+
+    La calidad como medio de transmitir confianza                     Desde el año 1992 el Laboratorio de Aerotécnica de                             Quality as a means to transmit confidence.                 9001 certified. In addition, quality systems for special
+                                                                      Soler & Palau Ventilation Group está acreditado por ENAC                                                                                  application products have also been certified including
+    En Soler & Palau Ventilation Group somos conscientes de que       para la realización de los ensayos de ventiladores en cuanto                   Soler & Palau Ventilation Group understands that quality   high temperature, ATEX and others.
+    la calidad es garantía de éxito, por ello está definida como una  a características, ruido y vibraciones de acuerdo a la norma                   is the guarantee of success and as such has strived to
+    cuestión de principios. Soler & Palau fue en 1989 la primera      ISO/IEC 17025.                                                                 achieve only the highest standards of quality in every     Since 1992, Soler & Palau Ventilation Group’s Aero-
+    empresa española homologada por AENOR.                                                                                                           aspect of the business as a matter of principle since its  Technical Laborator y in Spain has been accredited by
+                                                                      En la actualidad nuestro Laboratorio está acreditado a nivel                   foundation. Soler & Palau was the first Spanish company    ENAC to conduct airflow, noise and vibration tests on fans
+    Actualmente todos los centros productivos del Grupo están         internacional por el organismo ILAC-MIRA.                                      to obtain AENOR certification in 1989.                     in compliance with ISO/IEC 17025 standards.
+    certificados según la ISO-9001. Asimismo, se han homologado
+    sistemas de calidad para gamas de productos con ejecuciones                                                                                      All the Group’s production plants are currently ISO- Our Laboratory is currently accredited internationally by
+    especiales: Alta temperatura, ATEX y otros.                                                                                                                                                                                        ILAC-MIRA
+
+12                                                                                                                                                                                                                                                                                                13
+
+    Tenemos claro que la calidad es                                                                                                 Anecoic Chamber                                                                                                                         Climatic Chamber
+    el modo más seguro de ganarnos
+    la confianza.
+
+    We know that quality is the best way
+    to earn confidence.
+
+                                                                                                                                                                                                                                                                            Testing Performances
+SPAIN                                       Jorge Casino                                                                                                                                        UK- S&P              Alex Finch
+                                            Administration Manager                                                                                                                                                   Financial Cotroller
+Damián González                                                                                                                                                                                 Harvey Bantin
+Area Manager                                Xavier Subirana                                                                                                                                     Operations Director  Alasdair Howie
+                                            Industrial Applications                                                                                                                                                  Marketing Manager
+Joan Pessarrodona                           Manager                                                                                                                                             Eugene Scotcher
+Technical Support                                                                                                                                                                               Managing Director
+
+Pedro Pulido
+Commercial Director
+
+                                            SPAIN PRODUCT MANAGERS                                                                  AUSTRALIA
+                                            Vincenz Berger
+                                            Paul Mason                                                                              Hatice Mehmet
+                                            Juan Carlos Romero                                                                      Administration Manager
+                                            Laurent Broquedis
+                                                                                                                                    C.K.Cheng
+                                                                                                                                    General Manager
+
+                                                                                                                                    Stan Wood
+                                                                                                                                    Managing Director
+
+Investigación y desarrollo, una fuente de ventaja             Soler & Palau Ventilation Group permite y favorece el                 Research & Development, a source of                         The global nature of Soler & Palau Ventilation Group
+competitiva                                                   intercambio de conocimientos y experiencias entre los seis            competitive advantage                                       enables the transfer of knowledge and experience between
+                                                              centros de I+D, todos ellos dotados de modernos laboratorios                                                                      the four R&D centres. All of the R&D centres are equipped
+Soler & Palau Ventilation Group impulsa una gama de           homologados por prestigiosos organismos internacionales:              Soler & Palau Ventilation Group produces a wide range       with modern test laboratories certified by prestigious
+productos con un tronco común, adaptados a las necesidades                                                                          of products often derived from a common platform. This      international bodies:
+de los mercados locales. Para ello se han creado oficinas de  Zona Europea..................................... España (ENAC-ILAC)  common product platform is then adapted to suit the needs
+I+D en cada área geográfica, que investigan para incorporar   Zona Asiática............................. Shangai y Singapur (AMCA)  of the local markets. For this purpose R&D offices have     European area ..................................Spain (ENAC-ILAC)
+al catálogo los productos más adecuados en función de las     Zona Norte América....................... Estados Unidos (AMCA)       been set up in each geographical area to research and       Asian area .......................... Shangai & Singapore (AMCA)
+necesidades o legislación de cada país. La globalidad de      Zona Latino América......................... México y Brasil (AMCA)   develop products according to needs or legislation in each  North American area .................. United States (AMCA)
+                                                                                                                                    specific region.                                            Latin American area ................... Mexico & Brasil (AMCA)
+
+14                                                                                                                                                                                                                                                                 15
+
+         Ser innovadores significa futuro.
+         To be innovative means to have
+         a future.
+    ITALY               Mauro Cecconi                                                                                                                     MEXICO                                     Miquel Cuatrecasas Pascual
+                        Managing Director                                                                                                                                                            Managing Director
+    Sergio Croci                                                                                                                                          David Ortiz
+    Area Sales Manager  Roberto Cazzaniga                                                                                                                 Technical Manager                          Jose Luís Orbezo
+                        Area Sales Manager                                                                                                                                                           Commercial Director
+    Nadia Serravalle                                                                                                                                      José Antonio Martínez Villa
+    Logistic Manager                                                                                                                                      Administration Manager
+
+    Iuri Dal Corso
+    OEM Sales Manager
+
+                                         LATVIA                                                                                       CZECH REPUBLIC      Back:
+                                                                                                                                      Front:
+                                         Janis Zarins                                                                                                     Otakar Pump
+                                         Managing Director                                                                            Petr Koutník        AHU Department Director
+                                                                                                                                      Managing Director
+                                                                                                                                      ^                   Zuzana Eliášová
+                                                                                                                                      Ivan Cifrinec       Managing Assistant
+                                                                                                                                      R&D Director
+                                                                                                                                                          Martin Hendrich
+                                                                                                                                      Jirí Rak            Supply Chain Director
+                                                                                                                                      Marketing Director
+
+    El diseño pensando en la sostenibilidad                          ha hecho adoptar lo que se denomina ecodiseño como una           Designed with sustainability in mind                           savings, have led us to adopt what we call EcoDesign,
+                                                                     filosofía ineludible a partir de la cual han nacido conceptos                                                                   This design philosophy forms the basis of concepts such
+    En la actualidad, no basta con fabricar productos fiables y de   como la Demanda Controlada de Ventilación, los Sistemas          Today it is not enough to simply manufacture reliable and      as our Controlled Demand Ventilation and Intelligent
+    calidad. El ahorro y la eficiencia energética de los productos,  Inteligentes de Control o productos diseñados específicamente    high quality products. Energy savings and product efficiency,  Control System ranges along with products specifically
+    tanto en términos aerodinámicos como acústicos, son              para la recuperación de energía.                                 both in aerodynamic and acoustic terms, are the basic          designed to recover energy.
+    factores claves en el diseño de nuestros productos, de ahí                                                                        foundations for the design of our products. In this regard we
+    la adopción del software de simulación aerodinámica más          En consecuencia con esta filosofía, los ingenieros de            use the most advanced aerodynamic simulation software          In addition, as result of this philosophy, Soler & Palau
+    acreditado existente en el mercado.                              Soler & Palau Ventilation Group no sólo trabajan en los          and other technological productivity tools to assist our       Ventilation Group engineers not only work on efficiency
+                                                                     términos de eficiencia, sino que también tienen en cuenta        developments around the world.                                 but also take into account the recyclability of components
+    El firme compromiso de todas las empresas de Soler & Palau       la reciclabilidad de los componentes para evitar al máximo                                                                      for the purpose of reducing the environmental impact of
+    Ventilation Group con la eficiencia y el ahorro energético, nos  el impacto ambiental al final de la vida útil de los productos.  The firm commitment of all Soler & Palau Ventilation Group     products when they reach the end of their service life.
+                                                                                                                                      companies to improving product efficiency and energy
+
+16                                                                                                                                                                                                                                                               17
+
+    La energía es un bien escaso,
+    el ecodiseño es una prioridad.
+
+    Energy is a limited resource,
+    therefore Eco-design is a priority.
+                       FRANCE VIM              Frédéric Laurent                                                               CHILE                                                       Back:
+                                               Managing Director                                                              Front:
+                       Christian Potiron                                                                                                                                                  Claudio Lazo
+                       Purchasing Director     Ludivic Dournel                                                                Barbara Cavagnola                                           HVAC Sales Executive
+                                               Director North Region                                                          Distributors Sales Executive
+                       Bruno Forlini                                                                                                                                                      José Antonio Susacasa
+                       Director South Region   Natahlie Maldonado                                                             Antonio Pi                                                  Operations Manager
+                                               Administrative and Financial Director                                          Managing Director
+                       Laurent Vulliet                                                                                                                                                    Juan José Susacasa
+                       Production Director     Francis Valemberg                                                              Ana María Lagos                                             Commercial Manager
+                                               After Sales Service & Quality Manager                                          Commercial Assistant
+                       Ivan Bordas                                                                                                                                                        Cristián Alarcon
+                       R&D-Marketing Director                                                                                                                                             HVAC Sales Executive
+
+                                                                                                                                                                                          Facundo Muencke
+                                                                                                                                                                                          Ind. Sales Executive
+
+    GERMANY                                                                                                                                                                                                      CANADA
+
+    Nicole Heiler                                                                                                                                                                                                Faisal Khalil
+    Sales department                                                                                                                                                                                             Controller
+
+    Rolf Ortkamp                                                                                                                                                                                                 Roy McCrimmon
+    Managing Director                                                                                                                                                                                            President
+
+                                                                                                                                                                                                                 Matthew Medeiros
+                                                                                                                                                                                                                 General Manager
+
+    Las compras como factor de competitividad                     Con el Software de comunicación SUPPLY CHAIN en base a      Purchasing as a factor for competitiveness                  With our specialist internet-based supply chain
+                                                                  Internet hemos conseguido una eficiente comunicación con                                                                communication software, we have achieved efficient
+    Una buena gestión de compras y un sistema de calidad          nuestros proveedores.                                       Good purchasing management, combined with a good            communication with our suppliers.
+    concertada, son pasos imprescindibles para ser una empresa                                                                a quality system, are essential steps to becoming a
+    competitiva en un mercado global.                             Ponemos a su servicio un mercado de suministro global,      globally competitive company.                               We seek to take opportunity from a global supply market
+                                                                  que crece día a día, ofreciendo nuevas oportunidades en                                                                 by growing day by day, offering new opportunities in quality,
+    Una cadena extendida de proveedores distribuidos por todo el  calidad, competitividad y nuevas tecnologías, que en Soler  The Company has an extensive network of suppliers spread    competitiveness and new technologies that enable Soler &
+    mundo, innovando y trabajando en estrecha colaboración con    & Palau Ventilation Group se combinan para ofrecer a        all over the world, innovating and working with Soler &     Palau Ventilation Group to offer our customers products
+    Soler & Palau Ventilation Group contribuye a lograr su        nuestros clientes productos con una propuesta de valor      Palau Ventilation Group to achieve the satisfaction of our  with a continuously improved value proposal.
+    satisfacción como cliente.                                    permanentemente renovada.                                   customers.
+
+18                                                                                                                                                                                                                                                       19
+
+    La satisfacción de nuestros clientes
+    se inicia en la adquisición de las
+    materias primas.
+
+    Our customers satisfaction begins with
+    the purchase of the raw materials.
+    AUSTRIA                                                                                                                                            SPAIN FACTORIES                        José Manuel Sánchez
+                                                                                                                                                                                              Plant Manager
+    Mr.Ing. Othmar Schenk                                                                                                                              Jordi Corominas
+    Managing Director                                                                                                                                  Rodín & EMC Factory                    Francisco J. Vargas
+                                                                                                                                                       Plant Manager                          Madrid Plant Manager
+
+                                                                                                                                                       Joan Godayol
+                                                                                                                                                       Ripoll Plant Manager
+
+                                         IRELAND                                                                                 MALAYSIA
+
+                                         Mark Moran              Eamonn King                                                     L L Ong   Derek Seah
+                                         Project Sales Engineer  Director
+                                                                                                                                 Finance Manager Technical Director
+                                         Niamh Staunton          Edel Roche
+                                         Customer Service        Credit Controller                                               K H Teoh  A C Khoo
+
+                                         Frank Ludlow            Richard Williams                                                Managing Director General Manager
+                                         Sales Engineer          Managing Director
+
+    La producción adecuada a la demanda                          básicas para la fabricación de nuestros productos. Un buen      Production adapted to market demands                         balance between specialisation and flexibility means
+    de mercado                                                   equilibrio entre la especialización y la flexibilidad hace que                                                               our manufacturing methods are focused on obtaining
+                                                                 nuestros métodos de fabricación estén orientados a obtener      In our history of over 50 years designing and manufacturing  products with the greatest added value and delivered with
+    A lo largo de más de 50 años diseñando y produciendo         productos con mayor valor añadido y a dar un servicio rápido    fans, we have acquired a strong command of the different     a rapid and efficient service to meet the needs of each
+    ventiladores, hemos adquirido el conocimiento para dominar   y eficaz a la demanda del mercado.                              technologies that form the foundation of our production      specific market.
+    las diversas tecnologías que intervienen en los procesos                                                                     processes.
+    de producción.                                               Nuestra cercanía a los mercados finales facilita que nuestros                                                                Our local knowledge of the final markets enables out
+                                                                 productos se adecuen totalmente a las necesidades locales       Today we focus our attention on maintaining a high level     products to be perfectly adapted to local needs, according
+    Hoy estamos focalizando esfuerzos en mantener un alto nivel  en función de sus usos y aplicaciones.                          of development in technologies we consider as being          to use and application.
+    de desarrollo en aquellas tecnologías que consideramos                                                                       the foundations for manufacturing our products. A good
+
+20                                                                                                                                                                                                                                                        21
+
+    Dominamos la tecnología
+    de los procesos de producción.
+
+    We have the complete control of our
+    production process technology.
+PORTUGAL                                     Cátia Paquete                                                                                      UK-ENVIROVENT                               Andy Makin
+                                             Customer Service                                                                                                                               Distribution Sales Director
+Jorge Pinto                                                                                                                                     Caroline Wright
+Project Technical Advisor                    Luis Mota                                                                                          HR Director                                 Darren Chadwick
+                                             Customer Technical Advice Manager                                                                                                              Quality Director
+Carlos Barbas                                                                                                                                   Samantha Robinson
+Managing Director                                                                                                                               Commercial Services Director                Rebecca McLean
+                                                                                                                                                                                            Marketing Director
+                                                                                                                                                Nick Heaton
+                                                                                                                                                Managing Director
+
+                                             MIDDLE EAST                                                                       TAIWAN           Louis Wu
+                                                                                                                                                Marketing Manager
+                                             Amer Ahmad Fauri                                                                  K Y Yang
+                                             Business Development                                                              General Manager  May Hsu
+                                             Manager of Middle East                                                                             Finance Manager
+                                                                                                                               Judy Lo
+                                                                                                                               QA Manager
+
+Fabricamos productos con un importante valor                     El reto de futuro es introducir en el mercado productos y     We manufacture products with high added value                The challenge for the future is to continue to produce
+añadido                                                          sistemas de ventilación y recuperación de energía, con un                                                                  innovative, high quality ventilation, energy recovery
+                                                                 elevado nivel de diseño, que sean cada vez más eficientes     Today our catalogue includes over 10,000 standard            products and systems that are increasingly energy
+Las más de 10.000 referencias estándares de nuestro              y, sin renunciar a altas prestaciones, proporcionen un mayor  references and hundreds of thousands of variants that        efficient and provide more comfort without compromising
+catálogo y los cientos de miles de variables, hacen que          confort, además de reducir el consumo energético.             make our ventilation product portfolio one of the most       airflow and acoustic performance.
+nuestra oferta sea la más completa del mundo, con                                                                              comprehensive in the world. Our product range has
+respuestas a todas las necesidades del mercado ya sea para                                                                     been designed and developed in response to the needs
+entornos domésticos, industriales, agrícolas, sector terciario,                                                                of numerous global market requirements whether for
+procesos industriales u OEMs.                                                                                                  domestic, industrial, agricultural, industrial processes or
+                                                                                                                               OEM market sectors.
+
+22                                                                                                                                                                                                                                                   23
+
+          Nos anticipamos a las necesidades
+          del mercado.
+          We anticipate market needs.
+                       INDIA                  Trupti Gajanan Chavan                                                                                                                           CHINA GUANGZHOU
+                                              Finance Manager
+                       Sampat Shendage                                                                                                                                                        W B Wang
+                       Plant Manager          Abhijit Kamat                                                                                                                                   General Manager
+                                              Sales Manager
+                       Guruprasad Tiwari                                                                                                                                                      Zhang Lian
+                       Asst. General Manager                                                                                                                                                  Managing Director
+
+                                                                                                                                                                                              Yang Xiao
+                                                                                                                                                                                              Marketing Manager
+
+                                                                  INDIA NORTH         Kapil Kataria                            ROMANIA          Gabriel Popescu
+                                                                                      Sales Manager                                             Sales Coordinator
+                                                                  Shishir Shirvastav                                           Marian Maracine
+                                                                  Plant Manager       Swati Kedia                              Sales Engineer   Bogdan Petre
+                                                                                      Asst. Finance Manager                                     Managing Director
+                                                                  Vikas Shevale                                                Ionut Ilie
+                                                                  General Manager                                              Sales Engineer
+
+    Nuestro sistema logístico sitúa el producto de distribuidores exclusivos, capaces de resolver todo tipo de                 Our logistics system places the product close                  those of our exclusive distributor partners, we are able to
+                                                                                                                               to the client                                                  quickly respond and deliver products on a local level to our
+    cerca del cliente                                             problemas relacionados con sistemas de ventilación.                                                                         global network of customers.
+                                                                                                                               Soler & Palau Ventilation Group is one of the few ventilation
+    Soler & Palau Ventilation Group es una de las pocas empresas  De nuestras factorías en Europa, Asia y América salen al     companies that can offer a truly local coverage for the        Our factories in Europe, Asia and America produce more
+    de ventilación que puede ofrecer una cobertura mundial        mercado anualmente más de 5 millones de unidades de          distribution of its products on a worldwide basis. Through     than 5 million ventilation units a year, meaning that every
+    en la distribución de sus productos, ya sea a través de los   ventilación, lo que hace que cada 7 segundos un producto de  either Soler & Palau subsidiary company warehouses, or         7 seconds, a Soler & Palau Ventilation Group product is
+    almacenes reguladores de las filiales propias como por medio  Soler & Palau Ventilation Group se esté instalando en algún                                                                 being installed somewhere in the world.
+                                                                  punto del planeta.
+
+24                                                                                                                                                                                                                                                          25
+
+    Cada 7 segundos se instala
+    un producto de nuestras marcas
+    en algún lugar del mundo.
+
+    Every 7 seconds, one of our products
+    is being installed somewhere in
+    the world.
+    USA – RenewAire                                                                                                                                                            COLOMBIA           Rodrigo Zambrano
+    Doug Steege                                                                                                                                                                                   Administration Manager
+    Vice President of Sales & Marketing                                                                                                                                        Norberto Navas
+    Chuck Gates                                                                                                                                                                Sales Manager      Efrén Ospina
+    President                                                                                                                                                                                     Responsible Expeditions
+    Matthew Friedlander                                                                                                                                                        Daniel Prieto
+    Vice President of Engineering                                                                                                                                              Sales Area
+
+                                                          RUSSIA                                                                                                               Jorge Pinilla
+                                                          Victor Shansky                                                                                                       Managing Director
+                                                          Bussines Development Manager
+                                                          Alexey N Smirnov                                                                                         DUBAI
+                                                          Technical Manager
+                                                                                                                                                                   J C Sereno
+                                                                                                                                                                   Area Manager
+
+    Proporcionamos soporte técnico a nuestros                      También hemos desarrollado software especializado que         Providing technical support to our customers            We have also developed specialised computer software that
+    clientes                                                       ponemos a disposición de nuestros clientes y colaboradores
+                                                                   de forma gratuita, como el programa Easyvent de cálculo                                                               is placed at the disposal of our customers and partners
+    En Soler & Palau Ventilation Group siempre hemos               y selección de ventiladores, el VMC Select para resolver
+    entendido que debemos tener una colaboración estrecha          problemas relacionados con la Ventilación Mecánica            Soler & Palau Ventilation Group has always believed that free of charge. Software such as Easyvent, assists with the
+    con los clientes y prescriptores, compartiendo el caudal de    Controlada o el Heater para realizar cálculos de sistemas de
+    conocimiento que hemos acumulado a lo largo de los años.       calefacción eléctrica.                                        we should have a close collaboration with customers and selection of mechnical extract and supply fans; the VMC
+    Para ello, todas nuestras filiales proporcionan un Servicio
+    de Asistencia Técnica Gratuita, cuyos componentes son          Asimismo, disponemos de simuladores de comportamiento         par tners to be able to share the wealth of knowledge we Select software assists our customers with the selection of
+    técnicos especializados que ayudan a resolver los problemas    de fluidos para realizar estudios de gran precisión sobre el
+    relacionados con el movimiento y tratamiento del aire. Más de  movimiento de aire en grandes naves, garajes o túneles.       have accumulated over the years.                        Controlled Mechanical Ventilation systems, and our Heater
+    30.000 casos que nos plantean los profesionales del sector
+    son resueltos anualmente.                                                                                                                                                            Software calculates the heat load and therefore product
+
+                                                                                                                                 Today all our subsidiary companies provide free a Technical required for electrical heating systems.
+
+                                                                                                                                 Assistance Service, staffed by specialised technicians
+
+                                                                                                                                 who are there to assist and to provide our customers with Our Technical Assistance Services also use fluid dynamics
+
+                                                                                                                                 solutions for their air movement applications. On average modelling software to carry out high-precision studies on
+
+                                                                                                                                 the Soler & Palau Ventilation Group, Technical Assistance air movement in large buildings, garages or tunnels.
+
+                                                                                                                                 the Services departments receive some 30,000 enquires
+
+26                                                                                                                               per year.
+                                                                                                                                                                                                                                                                                            27
+
+    Ponemos nuestros conocimientos
+    y experiencia al servicio
+    de nuestros clientes.
+
+    Placing our knowledge and
+    experience at the service of
+    our customers.
+THAILAND                                        Wantana Noppimarn                                                                               SINGAPORE                              Grace Toh
+                                                Executive Director                                                                                                                     Purchasing Manager
+Somkiat Jongsathapornpong                                                                                                                       Y H Xie
+General Manager                                 Prachanart Neamnam                                                                              General Manager                        Alicia Loh
+                                                Marketing Manager                                                                                                                      Sales & Marketing
+Chaiagk Sonpho                                                                                                                                  Sean Lim                               Manager
+Managing Director                                                                                                                               Deputy General Manager
+
+                                                               BRAZIL                  Sérgio Groff                          NORWAY             Ivar Hovland
+                                                                                       OEM Commercial Manager                                   General Manager
+                                                               Denise Ferreira Ehlers                                        Jostein Jensen
+                                                               Marketing Manager       Cidnei Barbosa Dos Santos             Technical Manager  Johan Jakobsen
+                                                                                       Porto Alegre Commercial Manager                          Sales Manager
+                                                               Cláudia Alabarce                                              Johan Jensen
+                                                               Sâo Paulo Commercial                                          Offshore Manager
+                                                               Manager
+
+                                                               Carlos Ferreira Ehlers
+                                                               Managing Director
+
+Cuidamos el medio ambiente en nuestros                         devolverlas a la naturaleza en iguales o mejores condiciones  Caring for the environment in our production              Safety and Environmental management system based on
+procesos productivos                                           en que las recibimos. Esto es consecuencia del desarrollo     processes                                                 international OHSAS 18001 and ISO 14001 standards,
+                                                               por parte de Soler & Palau Ventilation Group de un sistema                                                              with the aim of guaranteeing that our processes and
+Un crecimiento constante y ordenado, no debe estar reñido      integrado de gestión de seguridad y medioambiente basado      At Soler & Palau Ventilation Group we believe that        products respect the safety and health of people and
+con un profundo respeto con el medio que nos rodea. En         en las normas internacionales OHSAS 18001 e ISO 14001         continuous and controlled growth should be combined with  will under no circumstances have a negative or damaging
+nuestras Empresas, reciclamos los deshechos de papel,          con el objetivo de garantizar que sus procesos y productos    a profound respect for the environment.                   effect on the environment.
+cartón, plásticos, cobre y en general de todo tipo de materia  son respetuosos con la seguridad y salud de las personas
+prima que necesitamos para la producción; asimismo,            y que en ningún caso puedan afectar de forma negativa al      Today our principle manufacturing facilities recycle paper,
+disponemos de sistemas de depuración de aguas para             medio ambiente.                                               cardboard, plastic, metal and generally any waste that
+                                                                                                                             could be used as raw material for production. In our
+28                                                                                                                           principle facilities we also have water purifying systems
+                                                                                                                             to return the water to nature in the same or even better
+         Somos respetuosos con el legado                                                                                     condition, than when it was received. This is the result of
+         a las siguientes generaciones.                                                                                      Soler & Palau Ventilation Group developing an integrated
+         We are respectful of the legacy to be
+         left for future generations.                                                                                                                                                                                                                                                   29
+LATIN AMERICA                                                                                                                                                 SWITZERLAND                      Thierry Godard
+Verónica Villanueva                                                                                                                                                                            Costumer Technical Advice
+Product Application Manager                                                                                                                                   Zoran Jugovic                    Manager
+                                                                                                                                                              Area Sales Manager
+                                                      UKRAINE                                                                                                                                  Hervé Vanplin
+                                                      Oleg Zhur                                                                                               Martin Thomann                   Area Sales Manager
+                                                      Business Development Manager                                                                            Area Sales Manager
+                                                      Roman Khomyn
+                                                      Business Development Manager                                                                            Frédéric Hernandez
+                                                                                                                                                              Managing Director
+
+                                                                                                                                                              SINGAPORE KEN
+
+                                                                                                                                                              David Lau
+                                                                                                                                                              General Manager
+
+                                                                                                                                                              Roger Yeo
+                                                                                                                                                              Sales Manager
+
+Una de las fortalezas del grupo es la capacidad estamos evaluando actualmente, y aquellas que se evaluarán                             One of the group’s strengths is its capacity to We are firmly dedicated to continue a strategy of growth
+
+de generar nuevos proyectos                                            en el futuro, deberán ofrecer sinergias al Grupo en términos    generate new projects                                   both organically and by acquisition. The companies and
+
+                                                                       de cobertura geográfica, extensión de gama de productos o                                                               opportunities we are currently assessing, and those to be
+
+La recesión iniciada en 2008 no ha frenado las iniciativas de mejora de cuota de mercado.                                              The recession that began in 2008 has not, in any way, assessed in the future, must offer synergies to the Group
+
+Soler & Palau Ventilation Group sino que las ha acelerado y                                                                            inhibited any reduction in innovation or investment at in terms of geographical coverage, extension of product
+
+hemos convertido los riesgos del entorno en oportunidades Durante los próximos años continuaremos nuestro proceso                      Soler & Palau Ventilation Group. On the contrar y it has range or improvement of market share.
+
+reales, reforzando el compromiso con nuestros clientes, de transformación de proveedor de productos a proveedor de                     accelerated our appetite to innovate and invest as the
+
+trabajando conjuntamente en la solución de sus problemas, sistemas de ventilación. Cada vez más, los clientes demandan                 Company has strived to turn the risks currently presented The next few years will see a continuation of our
+
+anticipándonos a sus necesidades y en todo caso soluciones de ventilación que sean fáciles de instalar, operar                         by the recession into opportunities by reinforcing our transformation process from a product supplier to a
+
+manteniendo un alto grado de calidad y fiabilidad en las y mantener y que, al mismo tiempo, tengan un coste global                     commitment to customers; working together to solve ventilation system provider. Our customers require
+
+propuestas de valor del Grupo.                                         competitivo teniendo en cuenta, no solamente la inversión       their problems; anticipating their needs and above all ventilation solutions that are simple to install, operate
+
+                                                                       inicial, sino a los gastos operacionales a lo largo de todo el  maintaining a high degree of quality and reliability in and maintain and which are competitively priced when
+
+Tenemos la firme voluntad de seguir creciendo tanto de ciclo de vida de la instalación.                                                our products.                                           considering not only the initial investment but throughout
+
+              forma orgánica como por adquisiciones. Las empresas que                                                                                                                          the working life of the product.
+30                                                                                                                                                                                                                                                                             31
+
+Hoy estamos poniendo los cimientos
+para seguir siendo fuertes y sólidos
+en el futuro.
+
+Today we are establishing the founda-
+tions for continued strength and sta-
+bility in the future.
+                    INDONESIA
+
+                    Rodemto
+                    General Manager
+
+                    Frans
+                    Asst. Production Manager
+
+                    Dea
+                    Financial Controller
+
+                                                                                                                                                                                     VIETNAM
+
+                                                                                                                                                                                     Truong Cong Tin
+                                                                                                                                                                                     Branch Manager
+
+                                                                                                                                                                                     Nguyen Thanh Toan
+                                                                                                                                                                                     General Manager
+
+                                                                                                                                                                                     Nguyen Manh Thang
+                                                                                                                                                                                     Sales Manager
+
+Obras emblemáticas                                                                                                      Prestigious projects
+
+La fiabilidad de los productos de Soler & Palau Ventilation   Ingeniería, distribuidores e instaladores y ha permitido  The reliability of Soler & Palau Ventilation Group products  distributors and installers around the world. This
+Group, la implantación del Grupo a nivel mundial, el soporte  que nuestros ventiladores estén instalados en obras       combined with our worldwide presence; technical              confidence in Soler & Palau Ventilation Group has led to
+técnico y el cumplimiento de los compromisos adquiridos,      emblemáticas en todo el mundo.                            support and commitment to excellence have earned us          our fans being installed in many prestigious construction
+han merecido la confianza de los departamentos de                                                                       the confidence of professional engineering departments,      projects all over the world.
+
+                                                                                                                                                                                                                                                                                                                                  33
+
+La confianza de nuestros clientes es la
+mejor garantía de un trabajo bien hecho.
+The confidence of our customers is the
+best guarantee of a job well done.
+15                                                   11                                                                                         10                                                          13  20                                                                                                                          19                                              18                                                      4                                                  7                                                        21
+
+14                                                   9                                                                                                                                                                                                                                                                                                                                                                                                                                                 12
+
+                                                                                                                                                                                                                                                                            16                                                              17                                                  5                                                                                                         17
+                                                                                                                                                2
+6                                                    8                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              1
+
+                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                       3
+
+34                                                   France                                        Morocco                                      Surgut                                                           • Chessington World of Adventures                              Guangzhou                                                   Powai                                           Johor Bahru                                             Singapore                                               • MRT System (Xinzhuang Line)                       Santos                                                                                                                 37
+                                                     Caen                                          Tager                                             • Aura shopping mall                                        • Ely College                                                                                                                                                                                                                                                                              • Municipal stadium
+ European area                                                                                                                                                                                                   • Honest Burger Chain                                               • Baiyun International Conference Centre                    • British Gas                                   • CIQ – Customs, Immigration & Quarantine               • AFPD (Toshiba) LCD Factory                       • Taipei 101                                             • Petrobrás administrative building                               Celaya
+ Algeria                                                  • IKEA                                        • Renault Factory                       Yaroslavl                                                        • Pizza Express                                                     • Guangzhou Baiyun International Airport               Indonesia                                               Complex                                              • Caterpillar Factory                         Thailand                                                 Telemaco Borba
+                                                     Lens                                          Portugal                                          • Aura shopping mall                                        • Streatham Labara                                                  • Guangzhou Honda Automobile co., Ltd                                                                                                                               • Downtown Line Stage 1                            • Central Department Store                                                                                                      • Honda
+       • Ain Defla and Bouira: UNO Shopping Centers                                                Guarda                                                                                                        • Victory Academy Norwich                                           • Line 1 Metro of Guangzhou                                 • Bubutan Golden Junction - B G Junction   Kuala Lumpur                                                 • Freeport                                         • Central World Plaza                                    • Hydropower Plant UHE Maua                                       Distrito Federal
+ Alger                                                    • Louvre Lens                                                                         Serbia                                                      London                                                                   • Poly International Plaza                                  • Factory of PT. Astra Honda Motor                                                                      • Gardens By The Bay                               • Central World Tower                               Lontras
+                                                     Lille                                              • Hospital da Guarda                         • Universiade                                               • Underground 7                                                     • Zhongshan Shangri-La Hotel                                • Lottemart Bintaro Jaya                        • Convention Centre                                     • Jurong Rock Cavern (Temporary Ventilation)       • Pratunam Complex                                                                                                              • Centro Comercial Antara 17
+       • CMA CGM Tower                                                                             Lisbon                                                                                                        • University City College                                      Shanghai                                                         • Pakubuwono Residence                          • Healthcare Centre Private Hospital                    • Kimberly-Clark                                   • Q-House Lumpini                                        • Hydropower Plant UHE Salto Pilão                                     • Cervantes 301
+       • International Airport                            • Grand Stade Lille Metropole                                                         Kruševac                                                         • Zoo                                                                                                                           • Regatta Apartment                             • Le-Meridien & Hilton International Hotels             • Marina Common Service Tunnel                     • Siam Paragon Complex                              Paracatu                                                                    • Gran Patio Santa Fe
+       • Siege Du Ministere Des Affaires Etrangeres  Lyon                                               • Cofina Sede                                • Cooper Tire                                                                                                                   • Anhui Radio & TV Center                                   • SCBD Lot 18                                   • Palace of Justice                                     • Metro Downtown Line-Stage 2                      • Suwanabhom Hotel                                                                                                              • Línea 12 del Metro
+ Tlemcen                                                                                                • Dolce Vita Tejo shopping mall                                                                     Asian area                                                               • Nanjing Greenland Square Zifeng Tower                     • The Adhiwangsa Residence                 Selangor D.E.                                                • OG Shopping Mall                                 • Tesco Lotus                                            • Hydropower Plant UHE Batalha                                         • Torre Vistral
+       • Hotel Renaissance Marriott                       • Confluence Museum 2                         • Judicial Police building              Poland                                                      China                                                                    • Shanghai Global Financial Centre                     Bali                                                                                                         • Raffles City Shopping Mall Phase 3          New Bangkok                                              Porto Velho                                                            Irapuato
+ Tlemcen and Oran                                    Marseilles                                         • Zon Multimedia building               Cracow and Poznan                                                                                                                    • Shanghai Pudong International Airport                                                                     • Sungai Buloh Hospital                                 • Rolls Royce Factory                              • International Airport (Suwanabhom Airport)
+       • Ibis Group Accor                                                                          Porto                                                                                                         • BaGuaShan Tunnel                                                  • Shanghai Tobacco Factory                                  • Conrad Resort & Spa                      Philippines                                                  • Sentosa                                     United Arab Emirates                                          • Hydropower Plant UHE Santo Antonio                                   • TsTECH
+ Belarus                                                  • History Museum                                                                           • Stadiums                                                  • Guangzhuo Luntou-Sheng Wu Tunnel                                  • Xiamen Xiangan Tunnel                                     • The Ritz-Carlton Resort & Spa                                                                         • The Ministry of Home Affairs 10             Abu Dhabi                                                Catalão                                                                Monterrey
+ Brest                                                    • MuCEM                                       • Dragão Caixa FC Porto Stadium         Spain                                                            • Wu Songshan Tunnel                                           Wuhan                                                       Bandung                                              • Bonifacio Ridge                                       • Tuas Power Ltd                                   • Abu Dhabi Police Head Quarters
+       • Korona Shopping Center                           • Regional Centre for the Mediterranean  Sintra                                       Barcelona                                                        • Xiang An Subsea Tunnel                                                                                                                                                        • Greenbelt 5                                           • United World College                        Palm Jumeirah                                                 • Hydropower Plant UHE Serra do Facão                                  • Estadio de Monterrey
+ Minsk                                               Orleans                                                                                                                                                     • Xiao Shan Airport Tunnel                                          • Chenzhou Olympic Sports Center                            • Braga City Walk                               • Manhattan Parkway                                     • Wind Tunnel Research Building at National        • Al Habtoor Hotel (7*) 14                          Guararema                                                                   • Hospital Medico Zambrano 18
+       • Power Station 5                                  • New Orleans Hospital                        • Forum Sintra                               • Barcelona Football stadium 5                              • Xin Baoxian Tunnel                                                • Chongqing Jiangbei International Airport             Jakarta                                              • One Corporate Center                                  • University of Singapore (NUS)                                                                                                                                                    • Torre LIU
+ Novopolotsk                                         Paris                                         Romania                                           • Forum building                                            • Xishan Taigu Tunnel                                               • Henan Art Centre                                                                                          • One Legaspi Place                                     • Woodsville Interchange                      North American area                                           • Compressor Station Petrobrás ECOMP                                   • Torre Sofía
+       • Polotsk State University                         • Philharmonie de Paris                                                                    • MNAC (National Art Museum of Catalonia)              Beijing                                                                  • Shanxi Liulin Coal Hotel                                  • Barkie Tower                                  • One McKinley Place                               Singapore                                               • Michelin US Health Center                         Araucária                                                              Panama
+ Belgium                                             Rennes                                             • Coca Cola Factory                     Madrid                                                           • Beijing Capital International Airport Terminal 3                  • Sichuan Radio & Television Center                         • Cyber 2                                       • Q Tower
+ Brussels                                                 • Centre Culinaire                       Bucarest                                          • Museo Reina Sofia                                         • Beijing Fortune Plaza                                             • Wuhan International Covention and Exhibition Center       • Kemang Village Jakarta                        • Skyway Twin Towers                                    • ArtScience Museum 11                        New Jersey                                                    • Refinery Presidente Vargas (Petrobrás)                               • Complejo SORTIS (Hotel, Casino y Business center) 19
+       • Dexia Tour Banquaire                        Villeneuve-d’Asq                                                                                • T4 Airport terminal 6                                     • Beijing Shangri-La Hotel                                     India                                                            • Kuningan City                                 • St. Francis Tower                                     • Marina Bays Gardens 12                           • Tiffany and Company National Distribution Center  Rio de Janeiro                                                              • Hotel Hilton Garden Inn.
+       • Kinetix Sport Center 1                           • Inesis Decathlon                            • Promenada Mall                        Salou                                                            • Capital Museum of China 8                                                                                                Aqaba                                                • St. Lukes Medical Center                              • Ministry of Home Affairs                                                                                                                                                         • Hotel RIU
+ Genk                                                Gabon                                         Russia                                            • Port Aventura                                             • CCTV Headquarters                                                 • Maruti Udyog                                                                                              • The Gramercy Residences                          Taiwan                                             Pittsburgh                                                    • Oil Platform PRA1                                                    • Línea 1 del Metro
+       • Ford Genk                                   Libreville                                    Kaluga                                       Santander                                                        • China Life Tower                                                  • Sahara City Centre                                        • Princess Haya Hospital                        • The MRT Depot Line 2                                                                                     • Bayer Corporation US Headquarters                      • Oil Platform P53                                                Playa del Carmen
+ Croatia                                                  • Cour Constitutionnelle de Libreville                                                     • Airport                                                   • China National Museum of fine arts                           Bangalore                                                   Korea                                                • Tiffany Court                                         • Corning Incorporated                                                                                      • Oil Platform BGL1
+ Slavonski                                           Greece                                             • Continental factory                   València                                                         • Dalian World Trade Center                                                                                                                                                Mabalacat                                                    • HsinChu Mackay Memorial Hospital            Latin American area                                           • Industrial Plant Peugeot                                             • Hotel Barceló Maya Beach 20
+       • Colosseum, Shopping Center                  Athens                                             • Volvo factory                              • Manisses Airport, City of Arts and Science                • LG Building                                                       • Knowledge Park                                            • Bundang Venture Town                                                                                  • Metro TaoYuan Airport                       Brasil                                                   Tocantins                                                                   • Hotel Iberostar Playa Mita
+ Czech Republic                                           • Athens Metro Stations                  Moscow                                       Turkey                                                           • Nation Museum of China                                       Delhi                                                            • Shinsegae Main Department Store               • Diosdado Macapagal International Airport              • Metro Xin Yi Line                           São Paulo                                                                                                                       Silao
+ Ostrava                                             Ireland                                                                                    Ankara                                                           • National Grand Theatre                                                                                                        • Korea Life 63 Building                   Manila                                                       • Metro Xin Zhuang Line                                                                                     • Hydropower Plant UHE Peixe 16
+       • IKEA                                        Dublin                                             • Hotel Moscow                               • Next Level, Residential, Office and Shopping center       • ZhongGuanCun Financial Centre                                     • Delhi Rail Metro Corporation                              • Bundang Venture Town                                                                                  • Taiwan High Speed Rail (HsinChu Station)         • Arena Corinthians football stadium                Vitória                                                                     • Pirelli 21
+ Egypt                                                    • Dublin Airport Terminal 2                   • Shopping Center June Auchan           Istanbul                                                                                                                        Mauritius                                                        • KBS Media Centre                              • Skyway Twin Corners                              Taipei                                                  • International Airport Tunnel                                                                                             Peru
+ Cairo                                               Italy                                              • Spartak Moscow Stadium                     • Zorlu Center                                                                                                                                                                              • M-City                                   Newport City                                                                                               Porto Alegre                                                  • Oil Platform P34                                                San Juanito
+       • Polygon, Residential & Offices              Milan                                              • Spartak stadium                       United Kingdom                                                                                                                       • Cyber City                                           Malaysia                                                                                                     • 101 Tower 13                                     • Beira Rio football stadium 15                     São José dos Pinhais
+                                                          • La Scala                                    • June shopping mall 3                       • All Saints School                                                                                                        Mumbai                                                                                                           • Marriot Hotel & Residential Resort                    • MRT System (Xinyi Line)                                                                                                                                                          • Hydropower Plant UHE Platanal
+                                                                                                   St. Petersburg                                    • Burger King                                                                                                                                                                               • Prime Minister’s Office (Perdana Putra)  Saudi Arabia                                                                                                                                                             • Industrial Plant Renault
+                                                                                                                                                     • CAU Restaurant Chain                                                                                                          • Airport                                                   • Traders Hotel KLCC                       Riyadh                                                                                                                                                              Chile
+                                                                                                        • Hermitage Museum                                                                                                                                                           • Grand Marhata Sheraton Tower ITC                          • Palace of Justice (Komplek Kehakiman 9                                                                                                                                                                       Santiago de Chile
+                                                                                                        • Renaissance Pravda business center 4                                                                                                                                       • Hiranadani Complex                                                                                        • KAP1, King Abdullah Project for the Development
+                                                                                                   Sochi                                                                                                                                                                             • Saifee Hospital                                              & Mahkamah)                                    of Security Centers                                                                                                                                               • Costanera Center
+                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                Ecuador
+                                                                                                        • Hotel Hayatt
+                                                                                                        • Olympic Village                                                                                                                                                                                                                                                                                                                                                                                                                                            • Hydropower Plant UHE Mazar
+                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                Mexico
+                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                Cancun
+
+                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     • Hotel Gran Meliá Cancún
+    CHINA WUHAN                                                                                                                OEM                                                       CHINA BEIJING
+
+    J X Yang                                                                                                                   Gustavo Figa                                              S J Li
+    Operation Manager                                                                                                          Senior Sales Director                                     Sales Director
+
+    X L Jiang                                                                                                                  Marc Serrano                                              Wang Yan
+    General Manager                                                                                                            Senior Sales Manager                                      General Manager
+
+    Guo Hua                                                                                                                    Alberto Pirovano                                          F L Duan
+    Finance Manager                                                                                                            Director                                                  Finance Manager
+
+                                                           NETHERLANDS           Maarten Smits 	                                                                                                          HONG KONG
+                                                                                 Inside Sales
+                                                           Berry van der Touw                                                                                                                             C F Yau
+                                                           Sales representitive  Alwin Krijnen                                                                                                            Manager
+                                                                                 Inside Sales & Technical service
+                                                           Hans Neeus  
+                                                           Managing Director
+
+    Proyección de futuro                                         Queremos crecer y evolucionar de acuerdo con nuestra          Vision for the future                                     Our desire is to grow and evolve as a Company in tune with
+                                                                 cultura basada en el respeto y la ética comercial, siguiendo                                                            our culture based on individual respect and commercial
+    En Soler & Palau Ventilation Group queremos seguir siendo    fieles a nuestras raíces de las que estamos orgullosos.       Soler & Palau Ventilation Group wishes to continue as     ethics whilst remaining faithful to our roots of which we
+    una empresa global que aplica políticas locales para seguir                                                                a global company applying local policies to maintain our  are proud.
+    creciendo ordenadamente, apoyándonos en nuestros             Deseamos ser reconocidos por nuestros clientes y              growth in a controlled manner supported by our customers
+    clientes y con el soporte de nuestro equipo humano.          colaboradores como el líder en quien confiar, no sólo por     and our workforce.                                        We wish to be seen by our customers and employees as a
+                                                                 nuestros productos, sino también por los valores humanos y                                                              leader they can trust, not only as a result of our products,
+    Incorporaremos las nuevas tecnologías que vayan surgiendo    profesionales de todas las personas que integran el Soler &   We will incorporate new technologies with the aim of      but also for the human and professional values of everyone
+    con el objetivo de conseguir la mejora constante en          Palau Ventilation Group.                                      achieving constant improvement in our products as well    working in Soler & Palau Ventilation Group.
+    nuestros productos así como del servicio que damos a                                                                       as continuously improving our services offered to our
+    nuestros clientes.                                                                                                         customers.
+
+    Trabajaremos para proponer al mercado productos y                                                                          We will strive to introduce even more efficient products
+
+    sistemas cada vez más eficientes que contribuyan a reducir                                                                 and systems into the market that reduce energy
+
+38  el consumo energético y a proteger el medio ambiente.                                                                      consumption whilst protecting the environment.                                                                          39
+
+    Entramos en el futuro con el reto de
+    seguir siendo líderes en el mercado
+    de ventilación.
+
+    Entering the future with the challenge
+    of remaining in the forefront of the
+    ventilation market .
+    Reconocimiento
+
+    Esta dilatada trayectoria, con un sólido presente y el
+    ilusionante futuro que tenemos por delante, empezó un día de
+    Febrero de 1951 gracias al empuje y el tesón de dos jóvenes
+    ingenieros: Eduardo Soler y José Palau, fundadores de la
+    compañía que durante muchos años pusieron conocimientos
+    y empeño para que aquella pequeña empresa se convirtiese
+    en la realidad actual.
+
+    1987 Acknowledgment
+
+    The foundation of our long histor y, solid present and
+
+40  exciting future ahead, began one February in 1951, thanks     41
+
+    to the efforts and tenacity of two young engineers: Eduardo
+
+    Soler and José Palau, founders of the company, and who
+
+    for many years placed their knowledge and determination
+
+    at the service of making their small company into what it
+
+    is today.
+ Soler & Palau Ventilation Group
+Sistemas de ventilación eficientes
+
+                                                                                                           43
+
+ Soler & Palau Ventilation Group
+    Efficient ventilation systems
+

+ 17550 - 0
media/documents/pdf/Catalogo_Renewaire.pdf

@@ -0,0 +1,17550 @@
+ERV
+                      SL, BR, GR & EV SERIES
+
+                                  SINGLE/MULTI-FAMILY ERV CATALOG
+
+JANUARY 2019
+
+RENEWAIRE.COM | 800.627.4499
+BECAUSE INDOOR
+
+AIR QUALITY MATTERS
+
+As buildings become more airtight due to better                                                 application of ERV technologies. Deficient IAQ is a
+construction methodologies, the need for increased                                              serious problem, especially considering:
+and balanced ventilation is critical. Without it, internally                                    u	On average, Americans spend 90% of their time indoors
+generated contaminants accumulate and cause deficient                                           u	The EPA found that indoor air may be 2-5 times—and
+indoor air quality (IAQ), which leads to significant
+health and cognitive problems for occupants. Industry                                              occasionally greater than 100 times—more polluted
+standards are changing to combat deficient IAQ, and                                                than outdoor air
+codes that adopt these new standards are driving the                                            u	The EPA ranks indoor air pollutants as a top-five
+                                                                                                   environmental health risk to occupants
+
+HEALTH    PRODUCTIVITY                                                                          LEARNING
+MAT TERS  MAT TERS                                                                              MAT TERS
+
+ADVERSE EFFECTS                                                                                 ABOUT RENEWAIRE
+
+O F DEFICIENT IAQ                                                                               For over 30 years, RenewAire has been
+                                                                                                a pioneer in enhancing IAQ in commercial and
+Deficient IAQ has numerous adverse effects on the                                               residential buildings of every size. This is achieved
+health and cognitive function of building occupants.                                            while maximizing sustainability through our fifth-
+                                                                                                generation, enthalpic-core, static-plate Energy
+                  Health problems: Acute allergies,                                            Recovery Ventilators (ERVs) that optimize energy
+                  headaches, coughs, asthma, skin                                               efficiency, lower capital costs via HVAC load
+                  irritations and breathing difficulties,                                       reduction and decrease operational expenses
+                  as well as chronic illnesses such as                                          by minimizing equipment needs, resulting
+                  cancer, liver disease, kidney damage                                          in significant energy savings. Our ERVs are
+                  and nervous-system failure.                                                   competitively priced, simple to install, easy to use
+                                                                                                and maintain, have a quick payback and enjoy the
+                  Cognitive impairment: Studies by the                                         industry’s best warranty with the lowest claims
+                  Harvard School of Public Health and the                                       due to long-term reliability. In 2010, RenewAire
+                  Lawrence Berkeley National Laboratory                                         joined the Soler & Palau (S&P) Ventilation Group,
+                  found that carbon dioxide (CO )—an                                            providing direct access to the latest in energy-
+                                                                                                efficient air-moving technologies. For more
+                                                                                             2  information, visit: renewaire.com.
+
+                  indoor air contaminant—negatively impacted
+                  thinking and decision-making at levels
+                  commonly found inside homes and buildings.
+                                                                                                                                                                                             TABLE OF CONTENTS
+
+                                TABLE OF
+
+CONTENTS
+
+ABOUT RENEWAIRE                                             2-3  GR SERIES - Unitary ERV
+SPECIFICATIONS & DIMENSIONS                                4-17
+OPTIONS & ACCESSORIES                                     18-23  MODEL             TYPE                  CFM RANGE PAGE
+CERTIFICATIONS & PERFORMANCE                              24-25  GR90 - STANDARD                         40-110 CFM 10
+ORDERING & SUPPORT                                        26-28                    Contractor-Grade,
+                                                                                   Four-Duct Connection
+
+SL SERIES - Unitary ERV
+
+MODEL                   TYPE                  CFM RANGE PAGE     EV SERIES - Unitary ERV
+SL70H - STANDARD                              51-76 CFM* 4-5
+                        Consumer-Grade,       51-76 CFM* 6-7     MODEL             TYPE                  CFM RANGE PAGE
+                        Four-Duct Connection                     EV90 - STANDARD                         40-110 CFM 11
+                                                                                   Consumer-Grade,       40-110 CFM 12
+SL70L - STANDARD        Consumer-Grade,                                            Four-Duct Connection  50-140 CFM 13
+                        Four-Duct Connection                                                             100-200 CFM 14
+                                                                 EV90P - STANDARD  Consumer-Grade,       100-240 CFM 15
+                                                                                   Four-Duct Connection  150-300 CFM 16
+*Continuous mode range
+                                                                                   Consumer-Grade,
+                                                                 EV130 - STANDARD  Four-Duct Connection
+
+                                                                 EV200 - STANDARD  Consumer-Grade,
+                                                                                   Four-Duct Connection
+BR SERIES - Unitary (Two Duct) ERV
+                                                                                   Consumer-Grade,
+MODEL                   TYPE                  CFM RANGE   PAGE   EV240 - STANDARD  Four-Duct Connection
+BR70 - STANDARD         Two-Duct Connection   40-70 CFM       8
+BR130 - STANDARD        Two-Duct Connection   50-140 CFM      9  EV300 - STANDARD  Consumer-Grade,
+                                                                                   Four-Duct Connection
+
+                                                                 FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 1
+   ABOUT RENEWAIRE
+
+   R E N E WA I R E E R Vs
+
+   ACHIEVE SUSTAINABLE IAQ
+
+   RenewAire is a pioneer in enhancing IAQ while maximizing sustainability through enthalpic-core, static-plate Energy
+   Recovery Ventilators (ERVs) that optimize energy efficiency, lower costs by reducing HVAC loads and therefore
+   reduce environmental footprints. Our ERV technology preconditions incoming air with the otherwise-wasted energy
+   (heat and humidity) of the exhaust air going out—all while the airstreams are kept physically separate as certified by
+   the Air Conditioning, Heating and Refrigeration Institute (AHRI) for zero exhaust air transfer at normal balanced operating
+   conditions. As the pioneer of static-plate core technology in North America, RenewAire is the largest ERV producer in the USA.
+
+   OPTIMIZING                                               OA  COOLING SEASON    RA        OA  HEATING SEASON         RA
+   ENERGY EFFICIENCY
+                                                                       EFFICIENT                       EFFICIENT
+   Energy efficiency is optimized by preconditioning            HEAT & HUMIDITY                 HEAT & HUMIDITY
+   the outside air coming in with the otherwise-wasted
+   heat and humidity of the exhaust air going out. This                TRANSFER                        TRANSFER
+   exchange of energy moderates temperatures and moisture,
+   decreases HVAC equipment needs, drives operational       EA                    FA        EA                         FA
+   efficiencies and conserves energy.
+
+   REDUCING HVAC LOADS                                                                               INSIDE                  OUTSIDE
+                                                                                                Fresh Air Enters       Stale Room Air Exits
+   RenewAire technology reduces HVAC loads during both winter and summer. In turn,
+   HVAC equipment size and needs can be decreased and furnaces and air conditioners           Fixed Partition
+   can be smaller. This process ensures efficient operations and keeps both energy use and  and Spacer Plates
+   costs low, while at the same time maintaining high-level IAQ.
+                                                                                               (proprietary resin
+                                                                                            and composite media)       Outside Air
+
+                                                                                                       Stale Room Air
+
+   MINIMIZING ENVIRONMENTAL IMPACT
+
+   The combination of less energy used and HVAC loads being reduced conserves resources. Further, our Madison, WI plant
+   is 100% powered by renewable wind energy, and is one of the few buildings worldwide to be LEED and Green Globes
+   certified, as well as having achieved ENERGY STAR Building status. This commitment to sustainable manufacturing
+   minimizes our overall production and distribution environmental footprint.
+
+2
+                                                                                                                                                                                                    ABOUT RENEWAIRE
+
+WHY RENEWAIRE
+
+IS PREFERRED
+
+                  BEST VALUE
+
+                       u Priced competitively against other ERV models
+                       u Due to competitive pricing and decreased costs, payback is short and ROI is maximized
+                       u Contractors can pass these significant savings along to their customers
+
+                  RELIABLE OPERATION
+
+                       u Built-to-last ERVs have lifespans of 25+ years and operate consistently year-round in every extreme,
+                          including frost-free performance in all but the most severe winter climates
+
+                       u High-efficiency core operates dry in all conditions, meaning no condensate pans
+                       u An industry-leading ten-year warranty for the static-plate core, two-year warranty for commercial
+
+                          products and a five-year warranty for residential products
+                       u Superior product quality results in paramount reliability and longevity
+
+                  HIGHEST-QUALITY INDOOR AIR
+
+                       u Stale indoor air is replaced with fresh, conditioned and filtered air from
+                          the outside, resulting in Enhanced IAQ by removing harmful contaminants
+
+                       u Airstreams do not mix and pollutants are not transferred across partition plates
+                       u No biocide used; material does not promote biological growth
+                       u Moderated temperatures and humidity maintain a comfortable indoor environment
+
+                  OPTIMIZED ENERGY EFFICIENCY
+
+                       u Efficient heat and humidity transfer recaptures up to 70-80% of the energy exhausted in the airstream
+                       u Energy that’s otherwise wasted by conventional ventilation systems (such as bath fans) is reused,
+
+                          thus dramatically reducing monthly operation costs
+                       u Energy-efficient operation decreases HVAC loads, which cuts down on energy use and costs
+                       u The hotter or colder the climate, the more energy is recovered
+
+                  HIGHLY CERTIFIED
+
+                       u See individual catalog submittal for certification details:
+                                 u UL u cUL u ETL u HVI u AHRI
+
+                                                                                                                                                                                                                                     3
+SPECIFICATIONS & DIMENSIONS
+
+SL 70H                                                               Energy Recovery Ventilator
+                                                                     EC Motor Standard
+
+INDOOR UNIT                                             NEW SPECIFICATIONS
+
+Download specification at:                                           Ventilation Type:                                                                                      Unit Dimensions & Weight:
+renewaire.com/specifications                                         Static plate, heat and humidity transfer                                                               27 1/4" L x 20 3/8" W x 9 1/2" H
+                                                                                                                                                                            32 lbs.
+                                                                     Continuous Operation Airflow: 51-76 CFM
+                                                                     Boost Mode Airflow: 76-94 CFM                                                                           Max. Shipping Dimensions & Weight (in carton):
+                                                                                                                                                                            29 1/2" L x 22 1/2" W x 11 1/2" H
+                                                                     Unit is HVI Tested/Certified per CSA C439                                                               38 lbs.
+                                                                     Protocol: Using one L-30 G5 Core
+                                                                                                                                                                            Motor(s):
+                                                                     Standard Features:                                                                                     Qty. 2, 48V DC motorized impeller packages
+                                                                     Unit may be mounted in any orientation
+                                                                     Low-voltage circuit for controls                                                                       Accessories:
+                                                                     Hard wiring in electrical box                                                                          Backdraft damper 6"
+                                                                     Dial-A-Flow - balance and airflow adjustment                                                            Wall cap 6" - white, brown
+                                                                     Variable speed                                                                                         Digital time clock - wall mount (TC7D-W),
+                                                                     Boost mode
+                                                                     Cross-core differential pressure ports                                                                    in exterior enclosure (TC7D-E)
+                                                                     Gray painted cabinet                                                                                   Carbon dioxide sensor/control - wall mount (CO2-W)
+                                                                                                                                                                            IAQ sensor - wall mount (IAQ-W)
+                                                                     Controls:                                                                                              Motion occupancy sensor/control -
+                                                                     Onboard digital controller with independent
+                                                                                                                                                                               ceiling mount (MC-C), wall mount (MC-W)
+                                                                        variable speeds                                                                                     Percentage timer control (PTL)
+                                                                                                                                                                            Percentage timer control with furnace interlock (FM)
+                                                                     Filters:                                                                                               Push-button point-of-use controls (PBL), PTL req’d.
+                                                                     Total qty. 2, MERV 8, spun-polyester media:                                                            MERV 13 filter - OA airstream
+                                                                                                                                                                            Wall bracket kit
+                                                                        7 1/2" x 10 1/2" x 1"                                                                               Electric duct heater - RH series (1-4 kW);
+
+                                                                                                                                                                               designed for indoor ductwork installation only
+
+EC MOTOR OPERATING RANGE                                             Note: Indirect Gas-Fired Duct Furnace is not availaSbLle7o0nPtheerSfLo7r0mH.ance Curve
+               Sample Points Depicted in Larger Dots
+                                                                                1.20
+
+                 Airflow (CFM)  External Static   Unit Power                                                                1.00
+                                  Pressure      Consumption
+
+                               (Inches Water       (Watts)
+                                  Column)
+
+                 82            0.1                      62
+
+                 77            0.2                      60           External Static Pressure (in. w.g.)                   0.80
+
+Continuous Mode  72            0.3                      59                                                                                                      BOOST
+
+                 67            0.4                      58                                                                                                      MODE
+
+                 61            Therma0l.5Performance Ra5ti6ngs for SL130 - Ext0r.a60polated from Catalog.xlsx SL130
+
+                 54            0.6                      54
+
+                 45            0.7                      51                                                                 0.40       CONTINUOUS
+
+                 34            0.8                      47                                                                                MODE                                         SyCsutermve
+
+                 108           0.1                      104
+
+                 102           0.2                      102                                                                0.20
+
+                 95            0.3                      100
+
+Boost Mode       91            0.4                      99                                                                 0.00
+
+                 89            0.5                      97                                                                       30   40  50                    60      70         80               90  100  110  120
+
+                 85            0.6                      96                                                                       = Actual tested sample points      Airflow (cfm)
+
+                 81            0.7                      94
+
+                 76            0.8                      92           CORE PERFORMANCE
+
+                 70            0.9                      89                                                                                Airflow (CFM)
+
+                 61            1.0                      85                                                Effectiveness (%)       30      60                        90             120
+
+Note: Watts is for the entire unit.                                                                                        100%
+Note: Airflow performance includes effect of clean, standard filter
+supplied with unit.                                                                                                          80%
+Note: Refer to CORES for specific operating point electrical data.
+                                                                                                                             60%
+
+ELECTRICAL DATA                 FLA             Min.        Max.          40%
+  Watts Volts HZ Phase          per              Cir.   Overcurrent       20%
+    96 120 60 1                motor            Amps    Protection
+                                                                            0%
+                                 2               10        Device                  At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+                                                             15      * See performance ratings per CSA C439 on page 25 of RenewAire’s Single/Multi-Family Catalog.
+
+Specifications may be subject to change without notice.
+
+4 RENEWAIRE.COM 1.800.627.4499
+                                                                     SL70H Energy Recovery Ventilator EC Motor Standard
+
+                                                                                                                                        2 1/4" Typ.        27 1/4" Overall  4 3/8" Typ.                                          ABBREVIATIONS
+                                                                                                                                                            22 7/8" Case                                                         EA: Exhaust Air to outside
+                                                                                                                                                                                                                                 OA: Outside Air intake
+                                                                                                                                            Power Outlet Box with 3' of Flexible Conduit                                         RA: Room Air to be exhausted
+                                                                                                                                               7/8" Knockouts                                                                    FA: Fresh Air to inside
+                                                                                                                                                                                                                                 INSTALLATION ORIENTATION
+                                                                                                                                                             TOP VIEW                                                            Unit may be installed in any
+                                                                                                                                                                                                                                 orientation.
+                                                                                                                                                                                                                                 NOTE
+                                                                                                                                                                                                                                 1.UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                 DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                 NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                 2.SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                 TO CHANGE WITHOUT NOTICE.
+
+                                                                          8" Nominal Typ.                                                                                   4 1/8" Typ.                      7 5/8" Minimum       9 1/2"
+                                                                     6" Nominal Typ.                                                                                                                            Service Area     Overall
+                                                                                                                                                                                                               (Door can be
+                                                                                                                                                                                                                                  9 1/8"
+                                                                                                                                                                                                              removed from        Case
+                                                                                                                                                                                                                       hinges.)
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 5  22" - 23" Overall                                                  EA                                  10 3/4" Typ.  SA  19 7/8" Minimum           18 5/8"                       21 1/4" Overall
+                                                                        (With Ceiling Brackets)                                                                                                  Service Area                                            (With Hanging Brackets)
+                                                                                                                                                                                                                        Door
+                                                                              19" Case                                                                                                                                  Swing
+                                                                                                       20 3/8" Overall
+                                                                                                                                        OA                                                RA
+                                                                       Control                                                                                              4 1/8" Typ.                                          2 1/8"
+                                                                     Terminals                                                          Pressure Ports                                                                 RIGHT VIEW   Minimum
+                                                                                                                                                 (4) Typ.
+                                                                                                                                                                                                                    (Hanging Mount Depicted)Latch
+                                                                                                                                                                                                                                           Clearance
+                                                                                                                                                                                                                                            UNIT MOUNTING & APPLICATION
+                                                                                  LEFT VIEW                                                                FRONT VIEW                                                                       Can be mounted in any orientation. RA/EA
+                                                                                                                                                                                                                                            airstream can be switched with OA/FA airstream.
+                                                                            (Hard Mount Depicted)
+                                                                     MAoIRdFeLl:OSWL70CHONFIGURATION
+                                                                     DArvaailwabilne gas Tshyopwen i:nUdinmietnDsioimn deranwisnigo. n
+                                                                     Version: DEC18
+
+                                                                                                                                                                                                                                                      SL-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+SL 70L                                                               Energy Recovery Ventilator
+                                                                     EC Motor Standard
+
+INDOOR UNIT                                             NEW SPECIFICATIONS
+
+Download specification at:                                           Ventilation Type:                                                                                  Unit Dimensions & Weight:
+renewaire.com/specifications                                         Static plate, heat and humidity transfer                                                           27 1/4" L x 20 3/8" W x 9 1/2" H
+                                                                                                                                                                        32 lbs.
+                                                                     Continuous Operation Airflow: 51-76 CFM
+                                                                     Boost Mode Airflow: 76-94 CFM                                                                       Max. Shipping Dimensions & Weight (in carton):
+                                                                                                                                                                        29 1/2" L x 22 1/2" W x 11 1/2" H
+                                                                     Unit is HVI Tested/Certified per CSA C439                                                           38 lbs.
+                                                                     Protocol: Using one L-30 G5 Core
+                                                                                                                                                                        Motor(s):
+                                                                     Standard Features:                                                                                 Qty. 2, 48V DC motorized impeller packages
+                                                                     Unit may be mounted in any orientation
+                                                                     Low-voltage circuit for controls                                                                   Accessories:
+                                                                     Line-cord power supply                                                                             Backdraft damper 6"
+                                                                     Dial-A-Flow - balance and airflow adjustment                                                        Wall cap 6" - white, brown
+                                                                     Variable speed                                                                                     Digital time clock - wall mount (TC7D-W),
+                                                                     Boost mode
+                                                                     Cross-core differential pressure ports                                                                in exterior enclosure (TC7D-E)
+                                                                     Gray painted cabinet                                                                               Carbon dioxide sensor/control - wall mount (CO2-W)
+                                                                                                                                                                        IAQ sensor - wall mount (IAQ-W)
+                                                                     Controls:                                                                                          Motion occupancy sensor/control -
+                                                                     Onboard digital controller with independent
+                                                                                                                                                                           ceiling mount (MC-C), wall mount (MC-W)
+                                                                        variable speeds                                                                                 Percentage timer control (PTL)
+                                                                                                                                                                        Percentage timer control with furnace interlock (FM)
+                                                                     Filters:                                                                                           Push-button point-of-use controls (PBL), PTL req’d.
+                                                                     Total qty. 2, MERV 8, spun-polyester media:                                                        MERV 13 filter - OA airstream
+                                                                                                                                                                        Wall bracket kit
+                                                                        7 1/2" x 10 1/2" x 1"                                                                           Electric duct heater - RH series (1-4 kW);
+
+                                                                                                                                                                           designed for indoor ductwork installation only
+
+EC MOTOR OPERATING RANGE                                             Note: Indirect Gas-Fired Duct Furnace is not availaSbLle7o0nPtheerSfLo7r0mL.ance Curve
+               Sample Points Depicted in Larger Dots
+                                                                                1.20
+
+                 Airflow (CFM)  External Static   Unit Power                                                                1.00
+                                  Pressure      Consumption
+
+                               (Inches Water       (Watts)
+                                  Column)
+
+                 82            0.1                      62
+
+                 77            0.2                      60           External Static Pressure (in. w.g.)                   0.80
+
+Continuous Mode  72            0.3                      59                                                                                                      BOOST
+
+                 67            0.4                      58                                                                                                      MODE
+
+                 61            Therma0l.5Performance Ra5ti6ngs for SL130 - Ext0r.a60polated from Catalog.xlsx SL130
+
+                 54            0.6                      54
+
+                 45            0.7                      51                                                                 0.40       CONTINUOUS
+
+                 34            0.8                      47                                                                                MODE                                         SyCsutermve
+
+                 108           0.1                      104
+
+                 102           0.2                      102                                                                0.20
+
+                 95            0.3                      100
+
+Boost Mode       91            0.4                      99                                                                 0.00
+
+                 89            0.5                      97                                                                       30   40  50                    60      70         80               90  100  110  120
+
+                 85            0.6                      96                                                                       = Actual tested sample points      Airflow (cfm)
+
+                 81            0.7                      94
+
+                 76            0.8                      92           CORE PERFORMANCE
+
+                 70            0.9                      89                                                                                Airflow (CFM)
+
+                 61            1.0                      85                                                Effectiveness (%)       30      60                        90             120
+
+Note: Watts is for the entire unit.                                                                                        100%
+Note: Airflow performance includes effect of clean, standard filter
+supplied with unit.                                                                                                          80%
+Note: Refer to CORES for specific operating point electrical data.
+                                                                                                                             60%
+
+ELECTRICAL DATA                 FLA             Min.        Max.          40%
+  Watts Volts HZ Phase          per              Cir.   Overcurrent       20%
+    96 120 60 1                motor            Amps    Protection
+                                                                            0%
+                                 2               10        Device                  At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+                                                             15      * See performance ratings per CSA C439 on page 25 of RenewAire’s Single/Multi-Family Catalog.
+
+Specifications may be subject to change without notice.
+
+6 RENEWAIRE.COM 1.800.627.4499
+                                                                     SL70L Energy Recovery Ventilator EC Motor Standard
+
+                                                                                                                                    2 1/4" Typ.    27 1/4" Overall  4 3/8" Typ.                               ABBREVIATIONS
+                                                                                                                                                    22 7/8" Case                                              EA: Exhaust Air to outside
+                                                                                                                                                                                                              OA: Outside Air intake
+                                                                                                                                                                                                              RA: Room Air to be exhausted
+                                                                                                                                                                                                              FA: Fresh Air to inside
+                                                                                                                                                                                                              INSTALLATION ORIENTATION
+                                                                                                                                                                                                              Unit may be installed in any
+                                                                                                                                                                                                              orientation.
+                                                                                                                                                                                                              NOTE
+                                                                                                                                                                                                              1.UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                              DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                              NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                              2.SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                              TO CHANGE WITHOUT NOTICE.
+
+                                                                                                                                                   TOP VIEW
+
+                                                                           8" Nominal Typ.                                                       34" Line Cord      4 1/8" Typ.       7 5/8" Minimum           9 1/2"
+                                                                     6" Nominal Typ.                                                                                                     Service Area         Overall
+                                                                                                                                                                                        (Door can be
+                                                                                                           EA                                                                                                  9 1/8"
+                                                                                                                                                                                       removed from            Case
+                                                                                                                                                                                                hinges.)
+
+                                                                                                                                                                                                 18 7/8"
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 7  22" - 23" Overall                                                                                            SA  19 7/8" Minimum  Door                        21 1/4" Overall
+                                                                        (With Ceiling Brackets)                                                                                          Service Area                                 (With Hanging Brackets)
+                                                                                                                                                                    10 3/4" Typ.                       Swing
+                                                                              19" Case
+                                                                                                        20 3/8" Overall  OA                                                       RA
+
+                                                                       Control                                                  Pressure Ports                      4 1/8" Typ.                               2 1/8"
+                                                                     Terminals                                                           (4) Typ.                                                                Minimum
+
+                                                                                                                                                                                                                     Latch
+                                                                                                                                                                                                                        Clearance
+
+                                                                                  LEFT VIEW                                                        FRONT VIEW                                                  RIGHT VIEW
+
+                                                                            (Hard Mount Depicted)                                                                                                      (Hanging Mount Depicted)
+                                                                     AMIRoFLdOeW l: SCL7O0NL FIGURATION
+                                                                     AvDailraablwe aisnsghoTwynpined:imUennsiitonDdirmaweinng.sion                                                                                      UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                                                        Can be mounted in any orientation. RA/EA
+                                                                      Version: DEC18                                                                                                                                    airstream can be switched with OA/FA airstream.
+
+                                                                                                                                                                                                                                     SL-SERIES
+   SPECIFICATIONS & DIMENSIONS
+
+   BR 70                                                            Energy Recovery Ventilator
+                                                                    Standard
+
+   INDOOR UNIT                                                      SPECIFICATIONS
+   Duct Mounted or Thru-the-Wall
+
+   Download specification at:                                       Ventilation Type:                                                          Filters:
+   renewaire.com/specifications                                     Static plate, heat and humidity transfer                                   Total qty. 2, MERV 8, spun-polyester media:
+
+                                                                    Typical Airflow Range: 40-70 CFM                                               7 1/2" x 10 1/2" x 1"
+
+                                                                    Unit is Tested to CSA C439 Protocol:                                       Unit Dimensions & Weight:
+                                                                    Using one L-30 G5 Core                                                     29 3/4" L x 19 1/4" W x 10 3/4" H
+                                                                                                                                               38 lbs.
+                                                                    Standard Features:
+                                                                    White painted cabinet                                                      Max. Shipping Dimensions & Weight (in carton):
+                                                                    Line-cord power supply                                                     30" L x 22" W x 15" H
+                                                                    Built-in control                                                           50 lbs.
+                                                                    Unit may be mounted in any orientation
+                                                                    Cross-core differential pressure ports                                     Motor(s):
+                                                                                                                                               Qty. 1, Double-shaft standard motor
+                                                                    Control:
+                                                                    Built-in proportional runtime control and switched                         Accessories:
+                                                                                                                                               Backdraft damper 6"
+                                                                       terminals for furnace/AC interconnect                                   Wall cap 6" - white, brown
+                                                                                                                                               Exterior thru-the-wall installation kit
+                                                                                                                                               Duct collar kit (two collars)
+                                                                                                                                               Electric duct heater - RH series (1-11.5 kW);
+
+                                                                                                                                                  designed for indoor ductwork installation only
+
+                                                                    Note: Indirect Gas-Fired Duct Furnace is not available on the BR70.
+
+   ELECTRICAL DATA                                                  UNIT PERFORMANCE                                                           CORE PERFORMANCE
+      HP Volts HZ Phase Input Watts FLA
+     0.08 120 60 Single 94 @ 69 CFM 1.0                                     Airflow CFM            ESP in H20                                   Temp EFF%                                                        Total EFF%
+                                                                                                                                                                                                             Winter/Summer*
+   UNIT DIMENSIONS
+                                                                               46                 0.40                                         80                                                            75/62
+
+                                                                               59                 0.30                                         77                                                            72/58
+
+                                                                               73                 0.20                                         75                                                            69/54
+
+                                                                               86                 0.10                                         72                                                            66/51
+
+                                                                    * See performance ratings per CSA C439 on page 25 of RenewAire’s Single/Multi-Family Catalog.
+
+   AIRFLOW CONFIGURATION
+   Available as shown in dimension drawing.
+
+   UNIT MOUNTING & APPLICATION                                      OA (TW)                                                                                                         36" Line Cord            ABBREVIATIONS
+                                                                    RA (DH)                                                                                                                                  EA: Exhaust Air to outside
+   Can be mounted in any orientation. If duct-mounted,                                                                                                               EA (TW)                                 OA: Outside Air intake
+   airstreams cannot be switched. If mounted with                     6"                                                                                             FA (DH)                                 RA: Room Air to be exhausted
+   exterior Thru-the-wall installation kit, the RA/EA                                                                                          Cut Hole in Duct                                              FA: Fresh Air to inside
+   airstreams are switched with the OA/FA airstreams.                                                                                          (Minimum Size)                                                TW: Thru Wall
+   If four ducts are connected using duct collar kit,                                                                                                                                                        DH: Duct Hung
+   airstreams may be switched.                                                                                                                                                                               INSTALLATION ORIENTATION
+                                                                                                                                                                                                             Unit may be installed in any
+                                                                    1 1/8"                    2"  17 5/8"                                                                                                    orientation.
+                                                                                                                                                                                                             NOTE
+                                                                                                  TOP VIEW                                                                                                   1.UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                             DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                             NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                             2. PRESSURE PORTS FOR EACH
+                                                                                                                                                                                                             AIR STREAM ARE LOCATED ON DOOR
+                                                                                                                                                                                                             OF UNIT.
+                                                                                                                                                                                                             3. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                             TO CHANGE WITHOUT NOTICE.
+
+                       19 1/2" Overall                                                            OA (TW)                                                                                          24V AC      Proportional   6" Typ.
+                                                                                                     RA (DH)                                                                                       Control     Runtime
+                        18 1/8" Case                                                                                               EA (TW)                                                         Terminal    Control
+   3/4"                                                                                                                               FA (DH)
+                                                                                                                                                                                                             CL 5 1/8"
+                                                                    5/8"
+                                                                                 2 1/4" Typ.
+
+                                                                    RA (TW)                                                                    FA (TW)    11"                                                                          8" Typ.
+                                                                    OA (DH)                                                                    EA (DH)       Overall
+                                                                                                                                                                  10 5/8"
+
+                                                                                                                                                                     Case
+
+                                        CL 4 1/2"                   CL 5 5/8"                         25 1/8" Case                             CL 6 1/8"
+                                  SEE NOTE 2
+                                                                                                    27 1/8" Overall                                                                                          Door             18 1/8" Minimum
+                                                                                                                                                                                                             Swing               Service Area
+                                                                                                    29 5/8" Overall
+                                                                                                  (with Duct Collars)
+
+                                 LEFT VIEW                                                        FRONT VIEW                                                                                                 18 1/8" Minimum
+                                                                                                                                                                                                               Service Area
+
+                                                                                                                                                                                                             RIGHT VIEW
+
+   Specifications may be subject to chanMgeowdiethlo: uBtRn7o0tice.
+   Drawing Type: Unit Dimension
+   RENEWAIRE.COM 1.800.62V7e.4r4s9io9n: JUN18
+8
+BR 130                                                                Energy Recovery Ventilator
+                                                                      Standard
+
+INDOOR UNIT                                                           SPECIFICATIONS
+Duct Mounted or Thru-the-Wall
+                                                                      Ventilation Type:                                   Filters:                                                                                                                                                                BR-SERIES
+Download specification at:                                            Static plate, heat and humidity transfer            Total qty. 2, MERV 8, spun-polyester media:
+renewaire.com/specifications
+                                                                      Typical Airflow Range: 50-140 CFM                       10 1/2" x 10 1/2" x 1"
+
+                                                                      Unit is HVI Tested/Certified per CSA C439            Unit Dimensions & Weight:
+                                                                      Protocol: Using one L-50 G5 Core                    33 1/2" L x 19 1/4" W x 13 1/2" H
+                                                                                                                          48 lbs.
+                                                                      Standard Features:
+                                                                      White painted cabinet                               Max. Shipping Dimensions & Weight (in carton):
+                                                                      Line-cord power supply                              32" L x 22" W x 18" H
+                                                                      Built-in control                                    60 lbs.
+                                                                      Unit may be mounted in any orientation
+                                                                      Cross-core differential pressure ports              Motor(s):
+                                                                                                                          Qty. 1, Double-shaft standard motor
+                                                                      Control:
+                                                                      Built-in proportional runtime control and switched  Accessories:
+                                                                                                                          Backdraft damper 6"
+                                                                         terminals for furnace/AC interconnect            Wall cap 6" - white, brown
+                                                                                                                          Exterior thru-the-wall installation kit
+                                                                                                                          Duct collar kit (two collars)
+                                                                                                                          Electric duct heater - RH series (1-11.5 kW);
+
+                                                                                                                             designed for indoor ductwork installation only
+
+                                                                      Note: Indirect Gas-Fired Duct Furnace is not available on the BR130.
+
+ELECTRICAL DATA                                                       UNIT PERFORMANCE                            CORE PERFORMANCE
+
+HP Volts HZ Phase Input Watts FLA                                     Airflow CFM       ESP in H20                         Temp EFF%                             Total EFF%
+0.1 120 60 Single 121 @ 124 CFM 1.3                                        52             0.70                                 82                            Winter/Summer*
+
+                                                                                                                                                                   78/65
+
+                                                                                 69             0.60                      80                                 75/62
+
+                                                                                 94             0.50                      76                                 71/57
+
+                                                                               113              0.40                      74                                 68/53
+
+                                                                               132              0.30                      71                                 65/49
+
+                                                                               141              0.20                      70                                 63/47
+
+                                                                               148              0.10                      69                                 62/46
+
+                                                                      * See HVI certification ratings on page 24 of RenewAire’s Single/Multi-Family Catalog.
+
+UNIT DIMENSIONS
+
+AIRFLOW CONFIGURATION                                                                     33 1/4" Overall                                                    ABBREVIATIONS
+Available as shown in dimension drawing.                                               (With Duct Collars)                                                   EA: Exhaust Air to outside
+                                                                                                                                                             OA: Outside Air intake
+                                                                                          30 7/8" Overall                 36" Line Cord                      RA: Room Air to be exhausted
+                                                                                                                                                             FA: Fresh Air to inside
+                                                                                           28 3/4" Case                                                      TW: Thru Wall
+                                                                                                                                                             DH: Duct Hung
+UNIT MOUNTING & APPLICATION                                           OA (TW)                                                                                INSTALLATION ORIENTATION
+                                                                      RA (DH)                                                                                Unit may be installed in any
+Can be mounted in any orientation. If duct-mounted,                                                                                                          orientation.
+airstreams cannot be switched. If mounted with       5 3/4"                    2 1/8"                                      EA (TW)                           NOTE
+exterior Thru-the-wall installation kit, the RA/EA    1 1/8"                                                               FA (DH)                           1.UNLESS OTHERWISE SPECIFIED,
+airstreams are switched with the OA/FA airstreams.                                                                                                           DIMENSIONS ARE ROUNDED TO THE
+If four ducts are connected using duct collar kit,                                                                Cut Hole in Duct                           NEAREST EIGHTH OF AN INCH.
+airstreams may be switched.                                                                                       (Minimum Size)                             2. PRESSURE PORTS FOR EACH
+                                                                                                                                                             AIR STREAM ARE LOCATED ON DOOR
+                                                                                                                                                             OF UNIT.
+                                                                                                                                                             3. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                             TO CHANGE WITHOUT NOTICE.
+
+                                                                                       20 3/8"
+
+                                                                                       TOP VIEW
+
+                                                                                                                                            24V AC                  Proportional
+                                                                                                                                            Control                 Runtime
+                                                                                                                                            Terminal                Control
+
+                                                                                                                                                                                        CL 5 1/8"
+                 8" Typ.       20 1/8" Overall                        CL 6 1/8"
+                        6" Typ.
+                 5/8"          18 1/8" Case                                                                               CL 4 5/8"
+                                                                                                                                      OA (TW)3/4"
+                                                                                                                                         RA (DH)
+                                                                                                                                                                       EA (TW)RA (TW)FA (TW)
+                                                                                                                                                                          FA (DH)OA (DH)EA (DH)
+                                                                                                                                                                                                                   13 3/4"
+                                                                                                                                                                                                                       Overall2 1/4" Typ.SEE NOTE 2Door
+                                                                                                                                                                                                                            13 3/8"Swing
+                                                                                                                                                                                                                                CaseCL 4 1/2"
+                                                                                                                                                                                                                                                                             18 1/8"
+                                                                                                                                                                                                                                                                                Minimum
+                                                                                                                                                                                                                                                                                    Service Area
+
+                                      LEFT VIEW                                        FRONT VIEW                                                                       18 1/2" Minimum
+                 Model: BR130                                                                                                                                             Service Area
+                 Drawing Type: Unit Dimension
+                 Version: JUN18                                                                                                                          RIGHT VIEW
+
+                                                                                                                                     Specifications may be subject to change without notice.
+
+                                                                                       FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 9
+    SPECIFICATIONS & DIMENSIONS
+
+    GR 90                                                                  Energy Recovery Ventilator
+                                                                           Standard
+
+    INDOOR UNIT                                                            SPECIFICATIONS
+
+    Download specification at:                                             Ventilation Type:                                               Filters:
+    renewaire.com/specifications                                           Static plate, heat and humidity transfer                        Total qty. 2, MERV 8, spun-polyester media:
+    ELECTRICAL DATA
+                                                                           Typical Airflow Range: 40-110 CFM                                   9 5/8" x 10 1/2" x 1"
+       HP Volts HZ Phase Input Watts FLA
+      0.03 120 60 Single 46 @ 90 CFM 0.35                                  Unit is HVI Tested/Certified per CSA C439                        Unit Dimensions: & Weight
+                                                                           Protocol: Using one L-35 G5 Core                                22 1/2" L x 11 3/4" W x 23 3/4" H
+    UNIT DIMENSIONS                                                                                                                        36 lbs.
+               AIRFLOW CONFIGURATION                                       Standard Features:
+               Available as shown in dimension drawing.                    Galvanized cabinet                                              Max. Shipping Dimensions & Weight (in carton):
+                                                                           Terminal strip hard wiring in ebox (no line cord)               29" L x 22" W x 15" H
+                                                                           Unit may be mounted in any orientation                          40 lbs.
+                                                                           Cross-core differential pressure ports
+                                                                                                                                           Motor(s):
+                                                                           Control:                                                        Qty. 2, Standard motorized impeller blowers
+                                                                           Can use any switched line-voltage power supply
+                                                                                                                                           Accessories:
+                                                                              (no low-voltage controls)                                    Backdraft damper 6"
+                                                                                                                                           Wall cap 6" - white, brown
+                                                                                                                                           120V line voltage Honeywell control
+                                                                                                                                           Electric duct heater - RH series (1-11.5 kW);
+
+                                                                                                                                              designed for indoor ductwork installation only
+
+                                                                           Note: Indirect Gas-Fired Duct Furnace is not available on the GR90.
+
+                                                                           UNIT PERFORMANCE                   CORE PERFORMANCE
+
+                                                                           Airflow CFM        ESP in H20                       Temp EFF%                                     Total EFF%
+                                                                                40              0.60                                                                     Winter/Summer*
+
+                                                                                                                                           84                            74/56
+
+                                                                               58                       0.50                               80                            69/50
+
+                                                                               73                       0.40                               77                            65/46
+
+                                                                               85                       0.30                               74                            62/43
+
+                                                                               98                       0.20                               71                            59/39
+
+                                                                               113                      0.10                               68                            56/34
+
+                                                                           * See HVI certification ratings on page 24 of RenewAire’s Single/Multi-Family Catalog.
+
+    UNIT MOUNTING & APPLICATION                                                                               12 1/4" Overall                                            ABBREVIATIONS
+                                                                                                                 (with Hanging                                           EA: Exhaust Air to outside
+    Can be mounted in any orientation. RA/EA airstream                                                               Bracket)                                            OA: Outside Air intake
+    can be switched with OA/FA airstream.                                                                                                                                RA: Room Air to be exhausted
+                                                                                                                                                                         FA: Fresh Air to inside
+                                                                                2 1/4" Typ.   22 1/2"                                                                    INSTALLATION ORIENTATION
+                                                                                              Overall                                                                    Unit may be installed in any
+                                                                           Power Wiring                                                                                  orientation.
+                                                                              Inlet 7/8"     18" Case                                                                    NOTE
+                                                                                                                                                                         1.UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                         DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                         NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                         2.SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                         TO CHANGE WITHOUT NOTICE.
+
+                                                                                                                              5 7/8" Typ.
+
+                                                                                             TOP VIEW
+
+                                      7/8" Typ.                                                               6 1/4"                            10 1/8" Minimum          11 5/8"
+                                                                                                                 Typ.                                Service Area         Case
+                                                                                                                                                    (Door can be
+                                                               Formed                Pressure Ports
+                                                               Inlet Ring                     (4) Typ.                                            Removed from
+                                                                                                                                                            Hinges.)
+                                                                   6" Nominal  OA
+                                                               Typ.                                                                                             21 1/4"
+                                                                                 EA
+           25 1/2" Overall            21 7/8" Case                 8" Nominal                                                   RA              22 1/4" Minimum  Door
+              (with Hanging bracket)                           Typ.                                                                                Service Area  Swing
+                                                                                                              11 3/4"                                                                    23 3/4"
+                                                                                                                 Typ.                                                                       Overall
+
+                                                                                                                              FA
+
+                                      2 5/8"                                                                  5 3/4"
+                                                                                                                 Typ.
+
+                                                    LEFT VIEW                                FRONT VIEW                                                                  RIGHT VIEW
+
+    Specifications may be subject to change without notice.
+
+    Model: GR90
+    RENEWAIRE.COM 1.800.627DV.er4a4rsw9io9inng: JTUyNp1e8: Unit Dimension
+10
+EV 90                                                          Energy Recovery Ventilator
+                                                               Standard
+
+INDOOR UNIT                                                    SPECIFICATIONS
+
+Download specification at:                                     Ventilation Type:                                          Filters:                                                           EV & GR-SERIES
+renewaire.com/specifications                                   Static plate, heat and humidity transfer                   Total qty. 2, MERV 8, spun-polyester media:
+ELECTRICAL DATA
+                                                               Typical Airflow Range: 40-110 CFM                              9 5/8" x 10 1/2" x 1"
+   HP Volts HZ Phase Input Watts FLA
+  0.03 120 60 Single 46 @ 90 CFM 0.35                          Unit is HVI Tested/Certified per CSA C439                   Unit Dimensions & Weight:
+                                                               Protocol: Using one L-35 G5 Core                           22 1/2" L x 11 3/4" W x 23 3/4" H
+UNIT DIMENSIONS                                                                                                           36 lbs.
+           AIRFLOW CONFIGURATION                               Standard Features:
+           Available as shown in dimension drawing.            White painted cabinet                                      Max. Shipping Dimensions & Weight (in carton):
+           UNIT MOUNTING & APPLICATION                         Line-cord power supply                                     29" L x 22" W x 15" H
+           Can be mounted in any orientation. RA/EA airstream  Low-voltage circuit for controls                           40 lbs.
+           can be switched with OA/FA airstream.               Unit may be mounted in any orientation
+                                                               Cross-core differential pressure ports                     Motor(s):
+                                                                                                                          Qty. 2, Standard motorized impeller blowers
+                                                               Control:
+                                                               Onboard 24 VAC transformer/relay package                   Accessories:
+                                                                                                                          Backdraft damper 6"
+                                                                  with switched dry contacts                              Wall cap 6" - white, brown
+                                                                                                                          Percentage timer control (PTL)
+                                                                                                                          Push-button point-of-use controls (PBL), PTL req’d.
+                                                                                                                          Percentage timer control with furnace interlock (FM)
+                                                                                                                          Electric duct heater - RH series (1-11.5 kW);
+
+                                                                                                                             designed for indoor ductwork installation only
+
+                                                               Note: Indirect Gas-Fired Duct Furnace is not available on the EV90.
+
+                                                               UNIT PERFORMANCE                          CORE PERFORMANCE
+
+                                                               Airflow CFM      ESP in H20                             Temp EFF%                                Total EFF%
+                                                                                                                                                            Winter/Summer*
+
+                                                               40              0.60                                       84                                74/56
+
+                                                               58              0.50                                       80                                69/50
+
+                                                               73              0.40                                       77                                65/46
+
+                                                               85              0.30                                       74                                62/43
+
+                                                               98              0.20                                       71                                59/39
+
+                                                               113             0.10                                       68                                56/34
+
+                                                               * See HVI certification ratings on page 24 of RenewAire’s Single/Multi-Family Catalog.
+
+                                                                 2 1/4" Typ.   22 1/2"                   12 1/4"                                            ABBREVIATIONS
+                                                                               Overall                      Overall                                         EA: Exhaust Air to outside
+                                                               24V AC                                           (with Hanging                               OA: Outside Air intake
+                                                               Control            18"                              Bracket)                                 RA: Room Air to be exhausted
+                                                               Terminal         Case                                                                        FA: Fresh Air to inside
+                                                                                                                                                            INSTALLATION ORIENTATION
+                                                                                                                                                            Unit may be installed in any
+                                                                                                                                                            orientation.
+                                                                                                                                                            NOTE
+                                                                                                                                                            1.UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                            DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                            NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                            2.SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                            TO CHANGE WITHOUT NOTICE.
+
+                                                                               TOP VIEW                  5 7/8" Typ.
+
+       7/8" Typ.                                                                                                               10 1/8" Minimum              11 5/8"
+                                                                                                                                    Service Area             Case
+                                                                                                                                   (Door can be
+                                                               34" Line Cord
+                                                                                                                                 Removed from
+                           Formed                                                            6 1/4"                                        Hinges.)
+                           Inlet Ring                                                           Typ.
+                                                                                                                                               21 1/4"
+                             6" Nominal Typ.
+25 1/2" Overall              8" Nominal Typ.                   OA                                                     RA            22 1/4" Minimum  Door
+   (with Hanging Bracket)                                        EA                                                                    Service Area
+                                                                                             11 3/4"                                                 Swing                  23 3/4"
+         21 7/8"                                                                                Typ.                                                                           Overall
+            Case
+                                                                                                                      FA
+
+       2 5/8"                                                      Pressure Ports            5 3/4"
+                                                                           (4) Typ.             Typ.
+
+               LEFT VIEW                                                         FRONT VIEW                                                              RIGHT VIEW
+                                                                                                                                    Specifications may be subject to change without notice.
+Model: EV90
+Drawing Type: Unit Dimension                                                   FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 11
+Version: JUN18
+    SPECIFICATIONS & DIMENSIONS
+
+    EV 90P                                                                 Energy Recovery Ventilator
+                                                                           Standard
+
+    INDOOR UNIT                                                            SPECIFICATIONS
+
+    Download specification at:                                             Ventilation Type:                                                Filters:
+    renewaire.com/specifications                                           Static plate, heat and humidity transfer                         Total qty. 2, MERV 8, spun-polyester media:
+    ELECTRICAL DATA
+                                                                           Typical Airflow Range: 40-110 CFM                                    21 3/4" x 10 1/2" x 1"
+       HP Volts HZ Phase Input Watts FLA
+      0.03 120 60 Single 44 @ 90 CFM 0.35                                  Unit is HVI Tested/Certified per CSA C439                         Unit Dimensions & Weight:
+                                                                           Protocol: Using one L-100 G5 Core                                22 1/2" L x 24" W x 23 3/4" H
+    UNIT DIMENSIONS                                                                                                                         51 lbs.
+               AIRFLOW CONFIGURATION                                       Standard Features:
+               Available as shown in dimension drawing.                    White painted cabinet                                            Max. Shipping Dimensions & Weight (in carton):
+               UNIT MOUNTING & APPLICATION                                 Line-cord power supply                                           33" L x 22" W x 29" H
+               Can be mounted in any orientation. RA/EA airstream          Low-voltage circuit for controls                                 65 lbs.
+               can be switched with OA/FA airstream.                       Unit may be mounted in any orientation
+                                                                           Cross-core differential pressure ports                           Motor(s):
+                                                                                                                                            Qty. 2, Standard motorized impeller blowers
+                                                                           Controls:
+                                                                           Onboard 24 VAC transformer/relay package                         Accessories:
+                                                                                                                                            Backdraft damper 6"
+                                                                              with switched dry contacts                                    Wall cap 6" - white, brown
+                                                                                                                                            Percentage timer control (PTL)
+                                                                                                                                            Push-button point-of-use controls (PBL), PTL req’d.
+                                                                                                                                            Percentage timer control with furnace interlock (FM)
+                                                                                                                                            Electric duct heater - RH series (1-11.5 kW);
+
+                                                                                                                                               designed for indoor ductwork installation only
+
+                                                                           Note: Indirect Gas-Fired Duct Furnace is not available on the EV90P.
+
+                                                                           UNIT PERFORMANCE                                    CORE PERFORMANCE
+
+                                                                           Airflow CFM                 ESP in H20                   Temp EFF%                                     Total EFF%
+                                                                                                                                                                              Winter/Summer*
+
+                                                                                       42             0.60                                  86                                83/71
+
+                                                                                       56             0.50                                  85                                82/70
+
+                                                                                       73             0.40                                  84                                80/68
+
+                                                                                       87             0.30                                  83                                79/67
+
+                                                                                       99             0.20                                  82                                78/66
+
+                                                                                       108            0.10                                  82                                78/65
+
+                                                                           * See HVI certification ratings on page 24 of RenewAire’s Single/Multi-Family Catalog.
+
+                                                                           2 1/4" Typ.                 22 1/2"                                                    ABBREVIATIONS
+                                                                                                       Overall                                                    EA: Exhaust Air to outside
+                                                                                                                                                                  OA: Outside Air intake
+                                                                                                      18" Case                                                    RA: Room Air to be exhausted
+                                                                                                                                                                  FA: Fresh Air to inside
+                                                                           24V AC                                 11 5/8"                                         INSTALLATION ORIENTATION
+                                                                           Control                                   Typ.                                         Unit may be installed in any
+                                                                           Terminal                                                                               orientation.
+                                                                                                                         24 1/4" Overall                          NOTE
+                                                                                                                             (with Hanging                        1.UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                  DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                Bracket)                          NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                  2.SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                  TO CHANGE WITHOUT NOTICE.
+
+                                                                                                      TOP VIEW
+
+                                 7/8" Typ.                                                                        6 1/4" Typ.                                22 1/4" Minimum  23 5/8"
+                                                                                                                                                               Service Area    Case
+                                                                                                                                                              (Door can be
+                                                                                       34" Line Cord
+                                                                                                                                                             Removed from
+    25 1/2" Overall                                                        8" Nominal                                                                              Hinges.)
+       (with Hanging Bracket)                                                 Typ.
+                                                                                                                                                                       Door
+             21 7/8"                                                       6" Nominal                                                                                  Swing
+                Case                                                          Typ.
+
+                                                                                       OA                                      RA           22 1/4" Minimum                                   23 3/4" Overall
+                                                                                                                                               Service Area
+                                                                                                                  11 3/4"
+                                                                                                                     Typ.
+
+                                                                                            EA                                 FA
+
+                                 2 5/8"                                    Formed           Pressure Ports        5 3/4" Typ.
+                                                                           Inlet Ring               (4) Typ.
+
+                                            LEFT VIEW                                                 FRONT VIEW                                                              RIGHT VIEW
+
+    Specifications may be subject to change without notice.
+
+    Model: EV90P
+    RENEWAIRE.COM 1.800.62VD7er.a4r4swi9oi9nng: JTUyNp1e8: Unit Dimension
+12
+EV 130                                                                 Energy Recovery Ventilator
+                                                                       Standard
+
+INDOOR UNIT                                                            SPECIFICATIONS                                                          Filters:                                                                 EV & GR-SERIES
+                                                                                                                                               Total qty. 2, MERV 8, spun-polyester media:
+Download specification at:                                             Ventilation Type:
+renewaire.com/specifications                                           Static plate, heat and humidity transfer                                   10 1/2" x 10 1/2" x 1"
+
+                                                                       Typical Airflow Range: 50-140 CFM                                        Unit Dimensions & Weight:
+                                                                                                                                               33 1/2" L x 13 1/4" W x 20" H
+                                                                       Unit is HVI Tested/Certified per CSA C439                                48 lbs.
+                                                                       Protocol: Using one L-50 G5 Core
+                                                                                                                                               Max. Shipping Dimensions & Weight (in carton):
+                                                                       Standard Features:                                                      32" L x 22" W x 18" H
+                                                                       White painted cabinet                                                   60 lbs.
+                                                                       Line-cord power supply
+                                                                       Low-voltage circuit for controls                                        Motor(s):
+                                                                       Unit may be mounted in any orientation                                  Qty. 1, Double-shaft standard motor
+                                                                       Cross-core differential pressure ports
+                                                                                                                                               Accessories:
+                                                                       Controls:                                                               Backdraft damper 6"
+                                                                       Onboard 24 VAC transformer/relay package                                Wall cap 6" - white, brown
+                                                                                                                                               Percentage timer control (PTL)
+                                                                          with switched dry contacts                                           Push-button point-of-use controls (PBL), PTL req’d.
+                                                                                                                                               Percentage timer control with furnace interlock (FM)
+                                                                                                                                               Electric duct heater - RH series (1-11.5 kW);
+
+                                                                                                                                                  designed for indoor ductwork installation only
+
+                                                                       Note: Indirect Gas-Fired Duct Furnace is not available on the EV130.
+
+ELECTRICAL DATA                                                        UNIT PERFORMANCE                                                    CORE PERFORMANCE
+   HP Volts HZ Phase Input Watts FLA
+   0.1 120 60 Single 102 @ 130 CFM 1.3                                                      Airflow CFM            ESP in H20               Temp EFF%                          Total EFF%
+                                                                                                                     0.60                                                  Winter/Summer*
+                                                                                                 79                  0.50
+                                                                                                 104                 0.40                      78                                          73/60
+                                                                                                 126                 0.30
+                                                                                                 137                 0.20                      75                                          69/55
+                                                                                                 153                 0.10
+                                                                                                 165                                           72                                          66/50
+
+                                                                                                                                               71                                          64/48
+
+                                                                                                                                               68                                          61/45
+
+                                                                                                                                               67                                          59/43
+
+UNIT DIMENSIONS                                                        * See HVI certification ratings on page 24 of RenewAire’s Single/Multi-Family Catalog.
+
+AIRFLOW CONFIGURATION
+Available as shown in dimension drawing.
+
+UNIT MOUNTING & APPLICATION                                                                          33 1/4" Overall          4 1/8" Typ.                                  ABBREVIATIONS
+Can be mounted in any orientation. RA/EA airstream                                                    28 3/4" Case                                                         EA: Exhaust Air to outside
+can be switched with OA/FA airstream.                                                                                                                                      OA: Outside Air intake
+                                                                                                                                                                           RA: Room Air to be exhausted
+                                                                               2 1/4" Typ.                                                                                 FA: Fresh Air to inside
+                                                                                                                                                                           INSTALLATION ORIENTATION
+                                                         6 3/8"                                                                                                            Unit may be installed in any
+                                                                                                                                                                           orientation.
+                                                                                                                                                                           NOTE
+                                                                                                                                                                           1.UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                           DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                           NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                           2.SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                           TO CHANGE WITHOUT NOTICE.
+
+                                                                       13 1/2" Overall                  31" Typ.
+
+                                                                                            6" Typ.  TOP VIEW                 6" Typ.              11 1/4" Minimum                                12 7/8"
+                                                                                                                                                        Service Area                               Case
+                                                                                                     34" Line Cord                                     (Door can be
+                                   7/8"        8"
+                                            Nominal                                                                                                  Removed from
+                                            Typ.                                                                                                               Hinges.)
+
+                 21 3/4" Overall   18 1/8"                        OA                                                                       EA         18 1/2"                                              20" Overall
+                    (with Hanging     Case                                                                                                               Minimum
+                                                                   RA                       9"                                                               Service Area  Door
+                        Bracket)
+                                                                                                                                           FA                              Swing
+
+                                                   6"                  Pressure Ports                                         8 1/8"                                              17 1/2"
+                                                Nominal                        (4) Typ.                                                                                     24V AC
+                                                Typ.2 5/8"                                                                                                                  Control
+                                                                                         FRONT VIEW                                                                        Terminal
+                                   LEFT VIEW                                                                                                                                               RIGHT VIEW
+
+                 Model: EV130                                                                                                                      Specifications may be subject to change without notice.
+                 Drawing Type: Unit Dimension
+                 Version: JUN18                                                                                   FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 13
+    SPECIFICATIONS & DIMENSIONS
+
+    EV 200                                                                  Energy Recovery Ventilator
+                                                                            Standard
+
+    INDOOR UNIT                                                             SPECIFICATIONS
+
+    Download specification at:                                              Ventilation Type:                                         Unit Dimensions & Weight:
+    renewaire.com/specifications                                            Static plate, heat and humidity transfer                  33 1/2" L x 24" W x 20" H
+                                                                                                                                      68 lbs.
+                                                                            Typical Airflow Range: 100-200 CFM
+                                                                                                                                      Max. Shipping Dimensions & Weight (on pallet):
+                                                                            Unit is HVI Tested/Certified per CSA C439                  34" L x 44" W x 34" H
+                                                                            Protocol: Using one L-100 G5 Core                         110 lbs.
+
+                                                                            Standard Features:                                        Motor(s):
+                                                                            White painted cabinet                                     Qty. 1, Double-shaft standard motor
+                                                                            Line-cord power supply
+                                                                            Low-voltage circuit for controls                          Accessories:
+                                                                            Unit may be mounted in any orientation                    Backdraft damper 6", 8"
+                                                                            Cross-core differential pressure ports                    Wall cap 6" - white, brown
+                                                                                                                                      Wall cap 8" - taupe vinyl, galvanized,
+                                                                            Controls:
+                                                                            Onboard 24 VAC transformer/relay package                     paintable galvanneal
+                                                                                                                                      Louver with 8" round duct connection -
+                                                                               with switched dry contacts
+                                                                                                                                         12" (W) x 8" (H)
+                                                                            Filters:                                                  Percentage timer control (PTL)
+                                                                            Total qty. 2, MERV 8, spun-polyester media:               Push-button point-of-use controls (PBL), PTL req’d.
+                                                                                                                                      Percentage timer control with furnace interlock (FM)
+                                                                               10 1/2" x 21 3/4" x 1"                                 Electric duct heater - RH series (1-11.5 kW);
+
+                                                                                                                                         designed for indoor ductwork installation only
+
+                                                                            Note: Indirect Gas-Fired Duct Furnace is not available on the EV200.
+
+    ELECTRICAL DATA                                                         UNIT PERFORMANCE                                      CORE PERFORMANCE
+       HP Volts HZ Phase Input Watts FLA
+       0.1 120 60 Single 157 @ 181 CFM 1.5                                      Airflow CFM                  ESP in H20                Temp EFF%                           Total EFF%
+                                                                                                                                                                       Winter/Summer*
+    UNIT DIMENSIONS
+                AIRFLOW CONFIGURATION                                                    122                       0.70               81                                                77/64
+                Available as shown in dimension drawing.
+                UNIT MOUNTING & APPLICATION                                              149                       0.60               79                                                75/61
+                Can be mounted in any orientation. RA/EA airstream
+                can be switched with OA/FA airstream.                                    168                       0.50               78                                                73/59
+
+                                                                                         176                       0.40               78                                                72/59
+
+                                                                                         186                       0.30               77                                                72/58
+
+                                                                                         192                       0.20               77                                                71/57
+
+                                                                                         207                       0.10               76                                                70/56
+
+                                                                            * See HVI certification ratings on page 24 of RenewAire’s Single/Multi-Family Catalog.
+
+                                                                            2 1/4" Typ.           33 1/4" Overall                                                      ABBREVIATIONS
+                                                                                                   28 3/4" Case                                                        EA: Exhaust Air to outside
+                                                                                                                                                                       OA: Outside Air intake
+                                                                                24 3/8" Overall                          11 7/8"                                       RA: Room Air to be exhausted
+                                                                                   (with Hanging                            Typ.                                       FA: Fresh Air to inside
+                                                                                                                                                                       INSTALLATION ORIENTATION
+                                                                                       Bracket)                                                                        Unit may be installed in any
+                                                                                                                                                                       orientation.
+                                                                                                                                                                       NOTE
+                                                                                                                                                                       1.UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                       DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                       NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                       2.SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                       TO CHANGE WITHOUT NOTICE.
+
+                                  21 3/4" Overall                                                 TOP VIEW
+                                     (with Hanging Bracket)
+                                                             6" Nominal         5 1/2"            34" Line Cord          6"                                            22 1/4" Minimum  23 7/8" Case
+                                         7/8" Typ.                    Typ.         Typ.                                     Typ.                                         Service Area
+                                                                                                                                                                         (Door can be
+
+                                                                                                                                                                        Removed from
+                                                                                                                                                                             Hinges.)
+
+                                  18 1/8"                                   OA                                                    EA              18 1/2"                                                20" Overall
+                                     Case                                                                                                            Minimum
+                                                                                         9"                                                              Service Area  Door
+                                                                                                                                                                       Swing
+                                                                            RA                                                    FA
+                                                                                                                                                                                               24V AC
+                                                             8" Nominal     Pressure Ports                               8 1/8"                                                                Control
+                                                                      Typ.          (4) Typ.                                                                                                   Terminal
+
+                                  2 5/8"                                                                                                                                         RIGHT VIEW
+
+                                                          LEFT VIEW                               FRONT VIEW
+    Specifications may be subject to change without notice.
+
+14  RENEWAIRE.COM 1.800.627M.4o4d99el: EV200
+
+                 Drawing Type: Unit Dimension
+                 Version: JUN18
+EV 240                                                                                                                                    Energy Recovery Ventilator
+                                                                                                                                          Standard
+
+INDOOR UNIT                                                                                                                               SPECIFICATIONS
+
+Download specification at:                                                                                                                Ventilation Type:                                                             Unit Dimensions & Weight:                                                                                                                                                           EV & GR-SERIES
+renewaire.com/specifications                                                                                                              Static plate, heat and humidity transfer                                      33 1/2" L x 24" W x 20" H
+                                                                                                                                                                                                                        70 lbs.
+                                                                                                                                          Typical Airflow Range: 100-240 CFM
+                                                                                                                                                                                                                        Max. Shipping Dimensions & Weight (on pallet):
+                                                                                                                                          Unit is HVI Tested/Certified per CSA C439                                      34" L x 44" W x 34" H
+                                                                                                                                          Protocol: Using one L-100 G5 Core                                             112 lbs.
+
+                                                                                                                                          Standard Features:                                                            Motor(s):
+                                                                                                                                          White painted cabinet                                                         Qty. 1, Double-shaft standard motor
+                                                                                                                                          Line-cord power supply
+                                                                                                                                          Low-voltage circuit for controls                                              Accessories:
+                                                                                                                                          Unit may be mounted in any orientation                                        Backdraft damper 6", 8"
+                                                                                                                                          Cross-core differential pressure ports                                        Wall cap 6" - white, brown
+                                                                                                                                                                                                                        Wall cap 8" - taupe vinyl, galvanized,
+                                                                                                                                          Controls:
+                                                                                                                                          Onboard 24 VAC transformer/relay package                                         paintable galvanneal
+                                                                                                                                                                                                                        Louver with 8" round duct connection -
+                                                                                                                                             with switched dry contacts
+                                                                                                                                                                                                                           12" (W) x 8" (H)
+                                                                                                                                          Filters:                                                                      Percentage timer control (PTL)
+                                                                                                                                          Total qty. 2, MERV 8, spun-polyester media:                                   Push-button point-of-use controls (PBL), PTL req’d.
+                                                                                                                                                                                                                        Percentage timer control with furnace interlock (FM)
+                                                                                                                                             10 1/2" x 21 3/4" x 1"                                                     Electric duct heater - RH series (1-11.5 kW);
+
+                                                                                                                                                                                                                           designed for indoor ductwork installation only
+
+                                                                                                                                          Note: Indirect Gas-Fired Duct Furnace is not available on the EV240.
+
+ELECTRICAL DATA                                                                                                                           UNIT PERFORMANCE                                                         CORE PERFORMANCE
+   HP Volts HZ Phase Input Watts FLA
+   0.2 120 60 Single 216 @ 236 CFM 3.3                                                                                                          Airflow CFM               ESP in H20                                Temp EFF%                                    Total EFF%
+                                                                                                                                                                                                                                                             Winter/Summer*
+UNIT DIMENSIONS
+            AIRFLOW CONFIGURATION                                                                                                                      170                                0.80                          78                                          72/59
+            Available as shown in dimension drawing.
+            UNIT MOUNTING & APPLICATION                                                                                                                195                                0.70                          76                                          70/56
+            Can be mounted in any orientation. RA/EA airstream
+            can be switched with OA/FA airstream.                                                                                                      214                                0.60                          75                                          69/54
+
+                                                                                                                                                       229                                0.50                          74                                          67/53
+
+                                                                                                                                                       242                                0.40                          73                                          67/53
+
+                                                                                                                                                       250                                0.30                          73                                          66/52
+
+                                                                                                                                                       256                                0.20                          73                                          65/51
+
+                                                                                                                                                       265                                0.10                          72                                          64/50
+
+                                                                                                                                          * See HVI certification ratings on page 24 of RenewAire’s Single/Multi-Family Catalog.
+
+                                                                                                                                          2 1/4" Typ.                    33 1/4" Overall                                                                     ABBREVIATIONS
+                                                                                                                                          2 1/4" Typ.                     28 3/4" Case                                                                       EA: Exhaust Air to outside
+                                                                                                                                                                                                                                                             OA: Outside Air intake
+                                                                                                                                                                         33 1/4" Overall                                                                     RA: Room Air to be exhausted
+                                                                                                                                                                          28 3/4" Case                                                                       FAAB:BFRrEeVshIAATIiOr tNoSinside
+                                                                                                                                                                                                                                                             IUFoROENAAAnrAiSe:i::tT:FnERAmOrxtoeLahauLostaAhtyimosuTiAbdnIsOAtei.erAiNrtiAnoitrOoisrtitnoaiRbnsIlietolEdeaNuedektTexsAiinhdTaeIaOunsNyted
+                                                                                                                                          24 3/8" 2O4v3er/8al"lOverall                          11 7/8" 11 7/8"                                              D1NoUINN.nrOEIUiMSeiAtNTTnEAERmLtNEELaaLSSStATIySiOoTEObnINIOGe.TSHNHiAnETOsRRHtWEaROIlRlEIeSFONEdATUSAiNnNPTEDIaINOCEnCNIDyFHIET.DO, THE
+                                                                                                                                             (with H (anwigtihngHanging                            Typ. Typ.                                                 D1N2TO..OISUMPNCTEEELHNCEASSIFISNOICOGNATESTHIWAOERRINTWEHSROIMSOEUAUTSYNPNEDBOCEETIDSFICUIETEBDO.J,ETCHTE
+                                                                                                                                                                                                                                                             NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                 Bracket)Bracket)
+                                                                                                                                                                                                                                                             2.SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                             TO CHANGE WITHOUT NOTICE.
+
+                                                                                                                                                                         TOP VIEW
+
+                                                            (with H (anwigtihngHaBrnagicnkget)Bracket)                                                                   TOP VIEW
+
+                              21 3/4" 2O1v3er/4al"lOverall                                              Typ.                                    5 1/2"                                                                                                       22 1/4" Minimum
+                                                                                                                                                   Typ.                                                                                                        Service Area
+                                                                                                        Typ.7/8"        6" Nominal                                       34" Line Cord              5 5/8" 5 5/8"                                              (Door can be
+                                                                                                                                 Typ.
+                                                                                                                                                5 1/2"                                                                                                       2R2e1m/4o"vMedinifmroumm
+                                                                                                        18Ca1s/e8"7/8"  6" Nominal        OA       Typ.                  34" Line Cord                             EA        18 1/2" 18 1/2"                   SerHviincgeeAs.r)ea              20" Over20al"lOverall
+                                                                                                                                                                                                                                MinimumMinimum                 (Door can be 23 7/8" Case
+                                                                                                                                                                                                                                    ServiceSAerreviace Area
+                                                                                                                                                                                                                                                              Removed from
+                                                                                                                                                                                                                                                                   Hinges.)
+
+                                                                                                                        Typ.                           9"                                                                                                    Door   23 7/8" Case
+                                                                                                                                                                                                                                                             Swing
+                                                                                                                                          ORAA                                                                     EFA
+                                                                                                        18 1/8"
+                                                                                                           Case                                        9"                                           8 3/8" 8 3/8"                                            Door
+                                                                                                                                                                                                                                                             Swing
+                                                                                                                          8" Nominal      RPAressur(e4)PoTyrtps.                                6"                 FA                                                         24V AC
+                                                                                                        5/8"                        Typ.                                                                                                                                      Control
+                                                                                                                                                                                                                                                                              Terminal
+                                                                                                        2                 8" Nominal      Pressure Ports                        FRONT VIEW                                                                                    24V AC
+                                                                                                                                            (HAN(4G) TINypG.             BRACKET REMOVED                                                                            RIGHT VTCeIoErmWntirnoal l
+                                                                                                        2 5/8"          LEFT VIETWyp.                                                           6"
+
+                                                                                                                                                                                                    FOR            CLARITY)
+
+                                                                                                                                                                         FRONT VIEW                                          Specifications may be subject to change without notice.
+
+               LEFT VIEW                                                                                                                  (HANGING BRACKET REMOVED FOR CLARITY)                                                                                     RIGHT VIEW
+Model: EV240
+Drawing Type: Unit Dimension                                                                                                                                             FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 15
+Version: JUN18
+    SPECIFICATIONS & DIMENSIONS
+
+    EV 300                                                              Energy Recovery Ventilator
+                                                                        Standard
+
+    INDOOR UNIT                                                         SPECIFICATIONS
+
+    Download specification at:                                          Ventilation Type:                                     Unit Dimensions & Weight:
+    renewaire.com/specifications                                        Static plate, heat and humidity transfer              33 3/4" L x 24" W x 20" H
+                                                                                                                              72 lbs.
+                                                                        Typical Airflow Range: 150-300 CFM
+                                                                                                                              Max. Shipping Dimensions & Weight (on pallet):
+                                                                        Unit is HVI Tested/Certified per CSA C439              34" L x 44" W x 34" H
+                                                                        Protocol: Using one L-100 G5 Core                     115 lbs.
+
+                                                                        Standard Features:                                    Motor(s):
+                                                                        White painted cabinet                                 Qty. 1, Double-shaft standard motor
+                                                                        Line-cord power supply
+                                                                        Low-voltage circuit for controls                      Accessories:
+                                                                        Unit may be mounted in any orientation                Backdraft damper 8"
+                                                                        Cross-core differential pressure ports                Wall cap 8" - taupe vinyl, galvanized,
+
+                                                                        Controls:                                                paintable galvanneal
+                                                                        Onboard 24 VAC transformer/relay package              Louver with 8" round duct connection -
+
+                                                                           with switched dry contacts                            12" (W) x 8" (H)
+                                                                                                                              Percentage timer control (PTL)
+                                                                        Filters:                                              Push-button point-of-use controls (PBL), PTL req’d.
+                                                                        Total qty. 2, MERV 8, spun-polyester media:           Percentage timer control with furnace interlock (FM)
+                                                                                                                              Electric duct heater - RH series (1-11.5 kW);
+                                                                           10 1/2" x 21 3/4" x 1"
+                                                                                                                                 designed for indoor ductwork installation only
+
+                                                                        Note: Indirect Gas-Fired Duct Furnace is not available on the EV300.
+
+    ELECTRICAL DATA                                                     UNIT PERFORMANCE                                  CORE PERFORMANCE
+       HP Volts HZ Phase Input Watts FLA
+       0.2 120 60 Single 315 @ 297 CFM 3.3                                  Airflow CFM                        ESP in H20      Temp EFF%                                  Total EFF%
+                                                                                                                  1.0                                                 Winter/Summer*
+                                                                                 170                              0.9
+                                                                                 191                              0.8         78                                      73/59
+                                                                                 215                              0.7
+                                                                                 256                              0.6         77                                      71/57
+                                                                                 277                              0.5
+                                                                                 295                              0.4         75                                      69/55
+                                                                                 311
+                                                                                                                              73                                      66/51
+
+                                                                                                                              71                                      65/49
+
+                                                                                                                              70                                      63/47
+
+                                                                                                                              69                                      62/46
+
+                                                                        * See HVI certification ratings on page 24 of RenewAire’s Single/Multi-Family Catalog.
+
+    UNIT DIMENSIONS
+
+    AIRFLOW CONFIGURATION                                                                                                                                      ABBREVIATIONS
+    Available as shown in dimension drawing.                                                                                                                   EA: Exhaust Air to outside
+                                                                                                                                                               OA: Outside Air intake
+    UNIT MOUNTING & APPLICATION                                         2 1/4" Typ.          33 1/4" Overall                                                   RA: Room Air to be exhausted
+                                                                                              28 3/4" Case                                                     FA: Fresh Air to inside
+    Can be mounted in any orientation. RA/EA airstream                                                                                                         INSTALLATION ORIENTATION
+    can be switched with OA/FA airstream.                               24 3/8" Overall                       9 3/4"                                           Unit may be installed in any
+                                                                           (with Hanging                         Typ.                                          orientation.
+                                                                                                                                                               NOTE
+                                                                               Bracket)                                                                        1.UNLESS OTHERWISE SPECIFIED,
+                                                                                    10"                                                                        DIMENSIONS ARE ROUNDED TO THE
+                                                                                       Typ.                                                                    NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                               2.SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                               TO CHANGE WITHOUT NOTICE.
+
+                     21 3/4" Overall                                                         TOP VIEW
+                        (with Hanging Bracket)
+                                                                            5 3/8"           34" Line Cord    5 1/2"                               22 1/4" Minimum    23 7/8" Case
+                              7/8" Typ.                                                                                                              Service Area
+                                                                                                                                                     (Door can be
+
+                                                                                                                                                    Removed from
+                                                                                                                                                         Hinges.)
+
+                                  18 1/8"                               OA  9 1/4"                                        EA  18 1/2"                                                 20"
+                                     Case                                                                                        Minimum                                                 Overall
+                                                                                                                                     Service Area              Door
+
+                                                                        RA                                                FA                                   Swing
+
+                                                To Fit                  Pressure Ports                        9 1/8"                                                       24V AC
+                                                8" Duct                         (4) Typ.                                                                                   Control
+                                  2 5/8"        Typ.                                                                                                                       Terminal
+
+                                                       LEFT VIEW                             FRONT VIEW                                                               RIGHT VIEW
+    Specifications may be subject to change without notice.
+
+16  RENEWAIRE.COM 1.800.6MD2ro7a.dw4e4in9l:g9EVTy3p0e0: Unit Dimension
+
+                     Version: JUN18
+APPLICATIONS
+
+BR-series Common Installation Approaches (BR70 and BR130)
+
+Bottom-Hung Lengthwise                                                           Bottom-Hung Crosswise                               Side-Hung                                Return Drop Hung
+
+www.renewaire.com (800) 627- 4499  support@renewaire.com                   www.renewaire.com (800) 627- 4499  support@renewaire.com
+
+EV-series Common Installation Approaches (EV130, EV200, EV240, and EV300) www.renewaire.com (800)627-4499
+                                                                                                                                                   support@renewaire.com
+
+                                                                                                                                                                          www.renewaire.com (800) 627- 4499  support@renewaire.com
+
+Separate Room Air Pick-up -                                                                                                          Separate Air and Fresh Air Supply
+Fresh Air to Furnace Return Air Trunkline
+
+Note: ERV blower may be operated separate from furnace blower.                                                                       Note: ERV blower may be operated separate from furnace blower.
+                                                                                                                                     www.renewaire.com (800) 627- 4499    support@renewaire.com
+
+Furnace Return Air Back into Return Air                                                                                              Furnace Return Air Back into Supply Air
+
+www.renewaire.com (800) 627- 4499                         support@renewaire.com
+
+Note: The furnace blower must be operated any time the ERV is operated. Use furnace                                                  Note: ERV blower may be operated separate from furnace blower.
+fan “on” continuous low speed or optional FM control to cycle furnace fan on ERV.
+
+EV-series Common Installation Approaches (EV90 and EV90P)
+
+                                                                                                                                     www.renewaire.com (800) 627- 4499    support@renewaire.com
+
+                                                          support@renewaire.com                                                      EA Exhaust Air
+Furnace Return Air Back into Return Air www.renewaire.com (800) 627- 4499
+
+                                                                                                                                     OA Outside Air
+
+                                                                                                                                     RA Room Air
+
+                                                                                                                                     SA Supply Air
+
+                                                                                                                                     FA Fresh Air
+
+Note: The furnace blower must be operated any time the ERV is operated. Use furnace
+
+fan “on” continuous low speed or optional FM control to cycle furnace fan on ERV.
+
+www.renewaire.com (800) 627- 4499                         support@renewaire.com
+
+                                                                                                                                     FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 17
+OPTIONS & ACCESSORIES
+
+ACCESSORIES
+
+Controls
+
+Standard controls are intended to turn RenewAire single/multi-family energy recovery ventilation systems on and off at appropriate
+times. Installation and set-up is an easy process. RenewAire single/multi-family units are available standard with interface and
+controls.
+BR Series: Built-in percentage run-time with furnace interlock
+GR Series: 120V line voltage controls
+EV Series: Percentage run timer or percentage run timer with furnace interlock and push button lighted controls
+
+      u Digital time clock, CO2 sensors, IAQ sensors and motion occupancy sensors - Can be applied with external 24V supply
+SL Series: Built-in low voltage transformer for use with percentage run timer or push button lighted controls for on/off, continuous and/or
+
+                   boost mode operation
+      u Digital time clock, CO2 sensors, IAQ sensors and motion occupancy sensors - Can be applied with internal low voltage transformer
+
+See individual submittal pages for availability by model.
+
+PERCENTAGE TIMER                                              u Two-wire, low-voltage connection
+
+Primary control for SL70, EV90, EV90P,
+EV130, EV200, EV240 & EV300
+
+u Units can run an adjustable amount of
+   time each hour
+
+PERCENTAGE TIMER WITH FURNACE INTERLOCK                                                                                PTL Control
+                                                                                                                       FM Control
+Alternate primary control for SL70, EV90,                                                                PBL Control - requires PTL Control
+EV90P, EV130, EV200, EV240 & EV300
+
+u Low-voltage wire connects to EV unit                        u Six-wire, low-voltage connection
+   and either thermostat or furnace control
+   to turn on furnace blower
+
+PUSH-BUTTON POINT OF USE TIMER
+
+Secondary control used in combination with
+PTL control for SL70
+
+u Push-button control turns on unit from                      u Push 2 times for 40 minutes or 3 times
+   bathrooms or other intermittent exhaust                       for 60 minutes
+   locations
+                                                              u Two-wire, low-voltage connection to PTL
+u One-touch, 20-minute run-time                                  control
+
+      Specifications may be subject to change without notice.
+18 RENEWAIRE.COM 1.800.627.4499
+                                                                                                           OPTIONS & ACCESSORIES
+
+ACCESSORIES
+
+See individual submittal pages for availability by model.
+
+DIGITAL TIME CLOCK                            u Wall mount or outdoor enclosure options
+                                              u Wall mount fits any 4" x 4" electrical box
+u Up to 8 on/off cycles per day or 56 per
+   week
+
+u 24 VAC power requirement
+u Battery back-up
+
+                                                                                             TC7D-W
+                                                                                            Wall Mount
+
+                                                                                                            TC7D-E Control In
+                                                                                                           NEMA 3R Enclosures
+
+CO2 SENSORS                                   u Self calibrates during periods of low
+                                                 occupancy
+u Adjustable control from 400-2000 PPM
+u Digital display                             u Wall mount or add duct mount accessory
+u 24 VAC power requirement
+u Computer/BAS interface for information and                                                                  CO2-D
+                                                                                                           Duct Mount
+   control
+
+                                                                                              CO2-W
+                                                                                            Wall Mount
+
+IAQ SENSORS                                   u Selectable 0-5 or 0-10V dc signal
+                                              u 24 VAC power required
+u Measures TVOC                               u Internal menu for easy set-up
+u Direct correlation to CO2 levels
+u 0-2000 ppm CO2 equivalent output                                                                            IAQ-D
+                                                                                                           Duct Mount
+   signal
+u Digital display on wall mount
+
+                                                                                              IAQ-W
+                                                                                            Wall Mount
+
+MOTION OCCUPANCY SENSORS
+
+u Passive infared sensor                      u Coverage floor space
+u Adjustable time-off delay to 30 minutes
+u 24 VAC power requirement                       - Ceiling mount: 1500 sq. ft.
+u Ceiling mount or directable wall mount         - Wall mount: 2500 sq. ft.
+
+                                              u Major motion area                               MC-C          MC-W
+                                                                                            Ceiling Mount  Wall Mount
+                                                 - Ceiling mount: 50 ft. diameter
+                                                 - Wall mount: 68 x 50 ft.
+
+                                                                                                  Specifications may be subject to change without notice.
+                                                           FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 19
+OPTIONS & ACCESSORIES                                          MERV13 Filter
+                                                              Wall Bracket Kit
+ACCESSORIES                                                   Painted Cabinet
+
+See individual submittal pages for availability by model.
+
+Filters
+
+MERV13 FILTERS (SL ONLY)
+u Pleated filter with beverage board fitted
+
+   frame for OA airstream
+
+Mounting
+
+WALL BRACKET KIT (SL ONLY)
+u For vertical installation on stud walls or
+
+   field-supplied support/backing panels
+
+Paint
+
+EXTERIOR PAINT
+u Custom colors available
+
+      Specifications may be subject to change without notice.
+20 RENEWAIRE.COM 1.800.627.4499
+                                                             OPTIONS & ACCESSORIES
+
+ACCESSORIES
+
+See individual submittal pages for availability by model.
+
+Hoods and Dampers
+
+VB106 & VW106                    u Low pressure drop design
+u 6" vinyl wall caps             u Cleanable metal screen
+u Brown (VB) or white (VW)
+
+VT8                              u 4 removeable flaps
+u 8" vinyl weatherhood           u 1/4" plastic screen
+u Taupe
+u 1-1/2" channel for siding      u Hood type wall cap
+                                 u 1/4" metal screen
+FA8-G
+u 8" wall cap
+u Galvanized finish
+
+FA8-P                            u Paintable
+u 8" wall cap                    u 1/4" metal screen
+u Galvanneal finish
+
+VW12X8                           u Flush mount
+u 12" x 8" x 8" round louver     u 1/2" metal screen
+u Galvanized finish
+
+BD6 & BD8                        u Male/female ends
+u 6" & 8" backdraft damper
+u Mechanical “butterfly” design
+
+                                                                                                    Specifications may be subject to change without notice.
+                                                             FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 21
+OPTIONS & ACCESSORIES
+
+ACCESSORIES
+
+RH Series Electric Duct Heater
+
+AVA I L A B L E O N S I N G L E / M U LT I - FA M I LY A N D L I G H T C O M M E R C I A L U N I T S ( S O M E E X C E P T I O N S A P P LY )
+
+RenewAire offers the highest-efficiency energy recovery ventilators (ERVs) on the market. However, during winter
+conditions, supply air from the ERV may be less than optimal for space conditions. By adding R E N E W A I R E ’ S
+R O U N D E L E C T R I C D U C T H E AT E R as an option to our single/multi-family and light
+commercial ERVs, RenewAire can now heat supply air during cooler months to enhance indoor comfort, all via one
+package for ERVs and heaters from a single source.
+
+                                                                RH SERIES
+                                                              RH-W SHOWN
+
+KEY BENEFITS                                                  u Easy installation: A ZERO clearance rating to combustibles
+                                                                 allows designers and contractors to apply RenewAire heaters
+u A single source reduces time and costs: A single               with less restrictions onsite.
+   information source, a single purchase point and a single
+   approval package for ERVs and heaters reduces design time  u Ultimate reliability: RenewAire heaters come with our two-year
+   and costs, and streamlines logistics for design engineers     warranty and unmatched reliability. Single-source responsibility
+   and contractors.                                              offers contractors and end users peace of mind and a single call
+                                                                 location for technical, start-up and commissioning questions.
+u More flexibility: RenewAire offers design engineers the
+   capacity to specify ERVs with a matching heater to boost   u Highly certified: CSA certified and evaluated to the applicable
+   flexibility and provide heated air to a single space or       ANSI/UL and CSA Standards, for use in the U.S. and Canada.
+   multiple spaces.
+
+      Specifications may be subject to change without notice.
+22 RENEWAIRE.COM 1.800.627.4499
+                                                                                                                                OPTIONS & ACCESSORIES
+
+RH SERIES                                           Electric Duct Heater (1-11.5 kW)
+                                                    Accessory
+
+                                                                                                                                                            LR 30551
+
+ELECTRIC DUCT HEATER               NEW              SPECIFICATIONS
+
+                                                    Heater Type:                                                   Standard Features:
+                                                    Electric Duct Heater                                           Open-coil element
+                                                                                                                   High grade nickel-chrome element wire
+                                                    Typical KW Range:                                              Thermostat - Integral (RH-D),
+                                                    1–11.5 kW (1, 2, 3, 4, 5, 6, 8, 10, 11.5 kW)
+                                                                                                                      Wall mount (RH-W)
+                                                    Voltages & Phase:                                              Modulating heat output (SCR control)
+                                                    Single phase - 120, 208 and 240V                               Vertical or horizontal operation
+                                                                                                                   Automatic limit switch for primary
+                                                    Control Voltage:
+                                                    24 VAC                                                            over-temperature protection
+                                                                                                                   Manual reset limit switch for secondary
+RH-D (Integral Thermostat)
+                                                                                                                      over-temperature protection
+                                                                                                                   Airflow sensor
+                                                                                                                   Standard control transformer - 24 VAC
+                                                                                                                   Corrosion resistant galvanized steel
+                                                                                                                   Round duct collars
+                                                                                                                   High voltage terminal block connections
+                                                                                                                   Grounding lug
+                                                                                                                   Mounting flanges
+
+                                                    Note: Electric duct heater designed for indoor ductwork installation only.
+
+                                                    Duct Collars                  kW                 V    Size     Width (X)    Height (Y)      Depth (Z)
+                                                         6"                                                        11 1/2"          8"          11 1/2"
+                                                         8"                       1, 2            120, 208, 240 A  11 1/2"         10"          13 1/2"
+                                                         8"                                                        11 1/2"         10"          13 1/2"
+                                                         10"                      3, 4, 5            208  B        11 1/2"         10"          13 1/2"
+                                                         10"                                                       11 1/2"         10"          13 1/2"
+                                                         10"                      3, 4, 5, 6         240  B        15 1/2"         12"          15 1/2"
+                                                         12"                                                       15 1/2"         12"          15 1/2"
+                                                                                  3, 4, 5            208  B
+
+                                                                                  3, 4, 5, 6         240  B
+
+     RH-W (Wall Mount Thermostat)                                                 8, 10, 11.5        240  C
+
+Download specification at:                                                        6, 8, 10, 11.5     240  C
+renewaire.com/specifications
+
+                                                    Y                     Z                                                     DIMENSIONS IN INCHES
+                                                                                                                                SIZE X Y Z
+                                                                              XA                  B       C
+                                                                                                                                 A 11.5 8.0 11.5
+                                                                                                                                 B 11.5 10.0 13.5
+                                                                                                                                 C 15.5 12.0 15.5
+
+                                                                                  RH SERIES HEATER CAPACITY
+                                                                              RH SERIES HEATER CAPACITY
+                                                                          13
+Minimum Airflow                     Heater Capacity  HEATER CAPACITY - kW
+      (CFM)                              (kW)                             12
+
+        30                               1.00                             11
+        60                               2.00
+        90                               3.00                             10
+        120                              4.00
+        150                              5.00                             9
+        180                              6.00
+        240                              8.00                             8
+        300                              10.00
+        345                              11.50                            7
+
+                                                                          6                                                     SAFE OPERATING
+                                                                          5
+                                                                                                                                RANGE
+                                                                          4
+
+                                                                          3
+
+                                                                          2
+
+                                                                          1
+
+                                                                          0
+
+                                                                              30 60 90 120 150 180 210 240 270 300 330 360 500 750 1000
+
+                                                                                                          AIRFLOW - CFM
+
+                                                                                                                                     Specifications may be subject to change without notice.
+                                                                                              FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 23
+CERTIFICATIONS & PERFORMANCE
+
+HVI TESTED/CERTIFIED
+
+PER CSA C439
+
+                      BR130 - Ventilation Performance                                                                  BR130 - Energy Performance
+
+Ext. Static Pressure  Net Supply Airflow                            Gross Airflow                  Supply    Net Airflow    Average      Sensible Recovery  Adjusted Sensible  Net Moisture
+                                                                                              Temperature  L/S CFM     Power Watts       Efficiency %         Recovery        Transfer %
+                                                           Supply                Exhaust      C° F°
+                                                                                                           58 124                                           Efficiency %
+Pa   in. wg           L/S        CFM     L/S                       CFM  L/S      CFM          Heating
+                                                                                                           59 126
+25   0.1              70         148     71                        151  75       159          0° 32°
+
+50   0.2              66         141     67                        143  69       147          Cooling
+
+75   0.3              62         132     63                        134  64       135          35° 95°                  121            72                    78                  55
+
+100  0.4              53         113     54                        115  56       119                                                      Total                 Adjusted Total
+
+125  0.5              44         94      45                        96   47                99                                          Recovery Efficiency %      Recovery Efficiency %
+
+150  0.6              32         69      33                        70   29                62                           121                46                                48
+
+175  0.7              24         52      25                        53   21                45
+
+                      EV90/GR90 - Ventilation Performance                                                              EV90/GR90 - Energy Performance
+
+Ext. Static Pressure  Net Supply Airflow                            Gross Airflow                  Supply    Net Airflow    Average      Sensible Recovery  Adjusted Sensible  Net Moisture
+                                                                                              Temperature  L/S CFM     Power Watts       Efficiency %         Recovery        Transfer %
+                                                           Supply                Exhaust      C° F°
+                                                                                                           42 90                                            Efficiency %
+Pa   in. wg           L/S        CFM     L/S                       CFM  L/S      CFM          Heating
+                                                                                                           42 90
+25   0.1              53         113     54                        115  52       109          0° 32°
+
+50   0.2              46         98      47                        100  46                97  Cooling
+
+75   0.3              40         85      41                        87   40                85  35° 95°                  46             72                    77                  37
+
+100  0.4              34         73      35                        74   34                72                                              Total                 Adjusted Total
+
+125  0.5              27         58      28                        59   28                60                                          Recovery Efficiency %      Recovery Efficiency %
+
+150  0.6              19         40      19                        41   22                47                           44                 46                                48
+
+                      EV90P - Ventilation Performance                                                                  EV90P - Energy Performance
+
+Ext. Static Pressure  Net Supply Airflow                            Gross Airflow                  Supply    Net Airflow  Average Power  Sensible Recovery  Adjusted Sensible  Net Moisture
+                                                                                              Temperature  L/S CFM          Watts        Efficiency %         Recovery        Transfer %
+                                                           Supply                Exhaust      C° F°
+                                                                                                           42 90                                            Efficiency %
+Pa   in. wg           L/S        CFM     L/S                       CFM  L/S      CFM          Heating
+                                                                                                           42 90
+25   0.1              51         108     52                        110  52       110           0° 32°
+
+50   0.2              47         99      48                        101  47       100          Cooling
+
+75   0.3              41         87      42                        89   42                89  35° 95°                  44             80                    83                  64
+
+100  0.4              35         73      36                        75   36                76                                              Total                 Adjusted Total
+
+125  0.5              26         56      27                        57   27                58                                          Recovery Efficiency %      Recovery Efficiency %
+
+150  0.6              20         42      20                        42   21                44                           44                 63                                71
+
+                      EV130 - Ventilation Performance                                                                  EV130 - Energy Performance
+
+Ext. Static Pressure  Net Supply Airflow                            Gross Airflow                  Supply    Net Airflow  Average Power  Sensible Recovery  Adjusted Sensible  Net Moisture
+                                                                                              Temperature  L/S CFM          Watts        Efficiency %         Recovery        Transfer %
+                                                           Supply                Exhaust      C° F°
+                                                                                                           61 130                                           Efficiency %
+Pa   in. wg           L/S        CFM     L/S                       CFM  L/S      CFM          Heating
+                                                                                                           61 130
+25   0.1              77         165     79                        168  79       168           0° 32°
+
+50   0.2              72         153     73                        156  73       156          Cooling
+
+75   0.3              64         137     66                        140  66       140          35° 95°                  102            71                    75                  53
+
+100  0.4              59         126     61                        129  61       129                                                      Total                 Adjusted Total
+
+125  0.5              49         104     50                        106  50       106                                                  Recovery Efficiency %      Recovery Efficiency %
+
+150  0.6              37         79      38                        81   38                81                           102                48                                51
+
+                      EV200 - Ventilation Performance                                                                  EV200 - Energy Performance
+
+Ext. Static Pressure  Net Supply Airflow                            Gross Airflow                  Supply    Net Airflow  Average Power  Sensible Recovery  Adjusted Sensible  Net Moisture
+                                                                                              Temperature  L/S CFM          Watts        Efficiency %         Recovery        Transfer %
+                                                           Supply                Exhaust      C° F°
+                                                                                                           85 181                                           Efficiency %
+Pa   in. wg           L/S        CFM     L/S                       CFM  L/S      CFM          Heating
+                                                                                                           85 180
+25   0.1              97         207     100                       213  109      232           0° 32°
+
+50   0.2              90         192     93                        199  104      221          Cooling
+
+75   0.3              88         186     90                        192  101      216          35° 95°                  157            78                    84                  62
+
+100  0.4              83         176     85                        181  96       204                                                      Total                 Adjusted Total
+
+125  0.5              79         168     81                        173  88       187                                                  Recovery Efficiency %      Recovery Efficiency %
+
+150  0.6              70         149     72                        154  76       162                                   155                52                                54
+
+175  0.7              57         122     59                        126  68       145
+
+                      EV240 - Ventilation Performance                                                                  EV240 - Energy Performance
+
+Ext. Static Pressure  Net Supply Airflow                            Gross Airflow                  Supply    Net Airflow  Average Power  Sensible Recovery  Adjusted Sensible  Net Moisture
+                                                                                              Temperature  L/S CFM          Watts        Efficiency %         Recovery        Transfer %
+                                                           Supply                Exhaust      C° F°
+                                                                                                           111 236                                          Efficiency %
+Pa   in. wg           L/S        CFM     L/S                       CFM  L/S      CFM          Heating
+                                                                                                           108 229
+25   0.1              125        265     129                       273  132      280           0° 32°
+
+50   0.2              121        256     124                       263  126      267          Cooling
+
+75   0.3              118        250     120                       254  121      256          35° 95°                  216            75                    80                  57
+
+100  0.4              114        242     116                       246  117      248                                                      Total                 Adjusted Total
+
+125  0.5              108        229     111                       235  110      233                                                  Recovery Efficiency %      Recovery Efficiency %
+
+150  0.6              101        214     103                       218  102      216                                   213                53                                56
+
+175  0.7              92         195     94                        199  93       197
+
+200  0.8              80         170     82                        174  79       167
+
+                      EV300 - Ventilation Performance                                                                  EV300 - Energy Performance
+
+Ext. Static Pressure  Net Supply Airflow                            Gross Airflow                  Supply    Net Airflow  Average Power  Sensible Recovery  Adjusted Sensible  Net Moisture
+                                                                                              Temperature  L/S CFM          Watts        Efficiency %         Recovery        Transfer %
+                                                           Supply                Exhaust      C° F°
+                                                                                                           139 297                                          Efficiency %
+Pa   in. wg           L/S        CFM     L/S                       CFM  L/S      CFM          Heating
+                                                                                                           138 294
+100  0.4              147        311     150                       317  143      303           0° 32°
+
+125  0.5              139        295     142                       301  133      283          Cooling
+
+150  0.6              131        277     133                       282  125      265          35° 95°                  315            67                    73                  54
+
+175  0.7              121        256     123                       261  108      230                                                      Total                 Adjusted Total
+
+200  0.8              101        215     103                       219  94       198                                                  Recovery Efficiency %      Recovery Efficiency %
+
+225  0.9              90         191     92                        195  74       156                                   313                46                                49
+
+250  1.0              80         170     82                        174  47                99
+
+                      SL70L/SL70H - Ventilation Performance                                                            SL70L/SL70H - Energy Performance
+
+Ext. Static Pressure  Net Supply Airflow                            Gross Airflow                  Supply    Net Airflow  Average Power  Sensible Recovery  Adjusted Sensible  Net Moisture
+                                                                                              Temperature  L/S CFM          Watts        Efficiency %         Recovery        Transfer %
+                                                           Supply                Exhaust      C° F°
+                                                                                                           25 53                                            Efficiency %
+Pa   in. wg           L/S        CFM     L/S                       CFM  L/S      CFM          Heating
+                                                                                                           25 53
+25   0.1              51         108     53                        112  55       117          0° 32°
+
+50   0.2              48         102     50                        106  53       112          Cooling
+
+75   0.3              45         95      48                        102  51       108          35° 95°                  29             75                    79                  57
+
+100  0.4              43         91      46                        97   49       104                                                      Total                 Adjusted Total
+
+125  0.5              42         89      44                        93   47       100                                                  Recovery Efficiency %      Recovery Efficiency %
+
+150  0.6              40         85      42                        89   44                93                           31                 62                                64
+
+175  0.7              38         81      40                        85   42                89
+
+200  0.8              36         76      38                        81   39                83
+
+225  0.9              33         70      35                        74   35                74
+
+250  1.0              29         61      31                        66   31                66
+
+24 RENEWAIRE.COM 1.800.627.4499
+                                                                                                                                               CERTIFICATIONS & PERFORMANCE
+
+INDEPENDENTLY TESTED
+
+PER CSA C439
+
+                      BR70 - Ventilation Performance                                                                            BR70 - Energy Performance
+
+Ext. Static Pressure                        Net Supply Airflow               Gross Airflow                  Supply    Net Airflow  Average Power  Sensible Recovery  Adjusted Sensible  Net Moisture
+                                                                                                       Temperature  L/S CFM          Watts        Efficiency %         Recovery        Transfer %
+                                                                    Supply                Exhaust      C° F°
+                                                                                                                    32 69                                            Efficiency %
+Pa   in. wg           L/S                   CFM                L/S          CFM  L/S      CFM          Heating
+                                                                                                                    30 64
+25   0.1              41                    86                 42           89   46                97   0° 32°
+
+50   0.2              34                    73                 35           75   39                84  Cooling
+
+75   0.3              28                    59                 29           61   32                69  35° 95°                  94             66                    75                  53
+
+100  0.4              21                    46                 22           47   25                53                                              Total                 Adjusted Total
+
+Electrical Requirements Volts 120 Amps 1.0                                                                                                     Recovery Efficiency %      Recovery Efficiency %
+
+                                                                                                                                94                 42                                47
+
+                                                                                                       FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 25
+  RENEWAIRE ERVs
+
+                     VENTILATION SOLUTIONS FOR EVERY APPLICATION
+
+                                                                SL SERIES
+
+                                                                                        u Residential ERVs—four-duct design
+                                                                                        u Indoor
+                                                                                        u 51-76 CFM continuous mode
+                                                                                        u 76-94 CFM boost mode
+
+                                                                BR SERIES
+
+                                                                                        u Residential ERVs—two-duct design
+                                                                                        u Indoor
+                                                                                        u 40-140 CFM
+
+                                                                EV SERIES
+
+                                                                                        u Residential and light commercial
+                                                                                            ERVs—four-duct design
+
+                                                                                        u Indoor/outdoor (varies by model)
+                                                                                        u 40-540 CFM
+
+                                                                HE SERIES
+
+                                                                                        u Commercial ERVs—packaged
+                                                                                            solutions
+
+                                                                                        u Indoor/outdoor
+                                                                                        u 250-7,950 CFM
+
+                                                                LE SERIES
+
+                                                                                        u Commercial ERVs—large capacity
+                                                                                        u Indoor/outdoor
+                                                                                        u 1,500-11,000 CFM
+
+        FOR CERTIFICATION DETAILS SEE UNIT SUBMITTALS ON RENEWAIRE.COM
+
+26 RENEWAIRE.COM 1.800.627.4499
+RENEWAIRE ERVs
+
+              VENTILATION SOLUTIONS FOR EVERY APPLICATION
+
+                                                            CA SERIES
+
+                                                                                   u Applied ERVs—modular cabinets
+                                                                                   u Indoor/outdoor
+                                                                                   u 500-4,400 CFM
+                                                                                   u Stackable to 20,000 CFM
+
+                                                            PA SERIES
+
+                                                                                   u Applied ERVs—modular panels
+                                                                                   u Indoor
+                                                                                   u 1500-unlimited CFM
+
+               RD SERIES
+
+               u Commercial—Dedicated Outdoor
+                  Air System (DOAS)
+
+               u Indoor/outdoor
+               u 500-4,250 CFM
+
+               DN SERIES
+
+               u Commercial—Dedicated Outdoor
+                  Air System (DOAS)
+
+               u Indoor/outdoor
+               u 375-4,950 CFM
+
+OPTIONS & ACCESSORIES
+
+u ECM motors   u Bypass economizers
+
+u Variable frequency drives u Electric duct heaters
+
+u Motorized isolation dampers u Filter alarms
+
+u Combo curbs
+
+FOR CERTIFICATION DETAILS SEE UNIT SUBMITTALS ON RENEWAIRE.COM
+
+                                                                                                                       FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 27
+ORDERING & SUPPORT
+
+                    INDOOR AIR QUALITY MATTERS
+
+                    u Deficient IAQ is an EPA top-five health risk
+
+                    u People spend 90% of their time indoors
+
+                    u Indoor air can be 2-5 times and up to 100 times
+                       more polluted than outdoor air
+
+BENEFITS OF INCREASED VENTILATION
+
+                                 BETTER          IMPROVED   INCREASED
+                                 HEALTH          COGNITIVE  PRODUCTIVITY
+                                                 FUNCTION
+
+TECHNICAL/APPLICATIONS SUPPORT
+The goal of our technical-support team is to provide the BEST CUSTOMER SERVICE
+in the HVAC industry. You can count on our knowledgeable and seasoned staff for all your technical,
+application and service needs, and we’ll respond quickly and effectively to answer any of your questions.
+
+                    CONTACT RENEWAIRE
+
+                                 PHONE:          FOR TECHNICAL SUPPORT:
+                                 1.800.627.4499  RenewaireSupport@renewaire.com
+
+                                 FAX:            TO PLACE AN ORDER:
+                                 608.221.2824    RenewaireOrders@renewaire.com
+
+28 RENEWAIRE.COM 1.800.627.4499
+RELEVANT                                                           RENEWAIRE
+
+EVERYWHERE                                                  TEMPERS THE AIR
+
+EVERY GEOGRAPHIC REGION                                    Our ERVs moderate the extremes
+Our ERVs function perfectly across the world in every      of outdoor supply-air temperature
+geographic region.                                         and humidity year-round, providing
+                                                           a sustainable solution for fresh air
+EVERY CLIMATE                                              that feels like a perfect spring day.
+Our ERVs operate in every climate—from Alaska to
+Florida, and everywhere in between.
+
+EVERY PROJECT
+From massive skyscrapers to cozy residential homes,
+our ERVs can be used in every size project and in every
+code jurisdiction.
+
+APPLIED EVERYWHERE
+
+When indoor occupants breathe in unclean air, this harms their health and causes cognitive impairment. Our ERVs can
+provide cleaner and healthier indoor air for every type of building in the world, thus improving occupants’ wellbeing,
+while also reducing energy costs.
+
+RESIDENTIAL                                                DAYCARE
+The increased airtightness of newer and remodeled          Crowded daycare facilities breed deficient IAQ, thus
+homes is causing deficient IAQ, resulting in more health   causing health problems for everyone—especially
+problems for indoor occupants.                             children who are more vulnerable.
+
+COMMERCIAL                                                 EDUCATION (LOWER AND HIGHER)
+As commercial buildings become more airtight,              With students and teachers packed into tight classrooms,
+deficient IAQ is increasing and causing sickness,          instances of deficient IAQ go up, resulting in academic
+absenteeism and decreased productivity.                    performance and test scores going down.
+
+H E A LT H C A R E                                         GOVERNMENT
+The high occupant density of hospitals, nursing homes      Aging and crowded government buildings result in
+and other healthcare facilities results in deficient IAQ   deficient IAQ, which can impair worker performance
+and ensuing health problems for patients and staff alike.  and productivity.
+
+RESTAURANTS/COFFEE SHOPS                                   EVERY TYPE OF BUILDING
+The large volume of indoor occupants in restaurants        Every type of building can benefit from the enhanced
+and coffee shops causes deficient IAQ and subsequent       IAQ generated by RenewAire ERVs, including
+health problems.                                           veterinary clinics, nail salons and manufacturing
+                                                           facilities, among others.
+RETAIL
+The high level of foot traffic in retail stores leads
+to deficient IAQ and the potential sickness of shoppers,
+which can negatively impact sales.
+        RENEWAIRE EVERYWHERE                                       LIT112_00 (01/19)
+
+       RenewAire ERVs can be applied everywhere across all
+         commercial, educational, institutional, light industrial
+
+      and residential buildings. Our technology excels in every
+     geographic region, every climate, and every size project.
+
+Member of the S&P Group
+Family of Brands
+ERV
+                        CA & PA SERIES
+
+                                      APPLIED CATALOG
+
+JANUARY 2019
+
+RENEWAIRE.COM | 800.627.4499
+BECAUSE INDOOR
+
+AIR QUALITY MATTERS
+
+As buildings become more airtight due to better                                                 application of ERV technologies. Deficient IAQ is a
+construction methodologies, the need for increased                                              serious problem, especially considering:
+and balanced ventilation is critical. Without it, internally                                    u	On average, Americans spend 90% of their time indoors
+generated contaminants accumulate and cause deficient                                           u	The EPA found that indoor air may be 2-5 times—and
+indoor air quality (IAQ), which leads to significant
+health and cognitive problems for occupants. Industry                                              occasionally greater than 100 times—more polluted
+standards are changing to combat deficient IAQ, and                                                than outdoor air
+codes that adopt these new standards are driving the                                            u	The EPA ranks indoor air pollutants as a top-five
+                                                                                                   environmental health risk to occupants
+
+HEALTH    PRODUCTIVITY                                                                          LEARNING
+MAT TERS  MAT TERS                                                                              MAT TERS
+
+ADVERSE EFFECTS                                                                                 ABOUT RENEWAIRE
+
+O F DEFICIENT IAQ                                                                               For over 30 years, RenewAire has been
+                                                                                                a pioneer in enhancing IAQ in commercial and
+Deficient IAQ has numerous adverse effects on the                                               residential buildings of every size. This is achieved
+health and cognitive function of building occupants.                                            while maximizing sustainability through our fifth-
+                                                                                                generation, enthalpic-core, static-plate Energy
+                  Health problems: Acute allergies,                                            Recovery Ventilators (ERVs) that optimize energy
+                  headaches, coughs, asthma, skin                                               efficiency, lower capital costs via HVAC load
+                  irritations and breathing difficulties,                                       reduction and decrease operational expenses
+                  as well as chronic illnesses such as                                          by minimizing equipment needs, resulting
+                  cancer, liver disease, kidney damage                                          in significant energy savings. Our ERVs are
+                  and nervous-system failure.                                                   competitively priced, simple to install, easy to use
+                                                                                                and maintain, have a quick payback and enjoy the
+                  Cognitive impairment: Studies by the                                         industry’s best warranty with the lowest claims
+                  Harvard School of Public Health and the                                       due to long-term reliability. In 2010, RenewAire
+                  Lawrence Berkeley National Laboratory                                         joined the Soler & Palau (S&P) Ventilation Group,
+                  found that carbon dioxide (CO )—an                                            providing direct access to the latest in energy-
+                                                                                                efficient air-moving technologies. For more
+                                                                                             2  information, visit: renewaire.com.
+
+                  indoor air contaminant—negatively impacted
+                  thinking and decision-making at levels
+                  commonly found inside homes and buildings.
+                                                                                                                                                                                             TABLE OF CONTENTS
+
+                                TABLE OF
+
+CONTENTS
+
+CA SERIES - Applied  TYPE     CFM RANGE         PAGE
+                     Indoor   500-2,200 CFM       4-5
+MODEL                Indoor   750-3,300 CFM      4, 6
+CA2XIN               Indoor   1,000-4,400 CFM    4, 7
+CA3XIN               Rooftop  500-2,200 CFM       8-9
+CA4XIN               Rooftop  750-3,300 CFM
+CA2XRT               Rooftop  1,000-4,400 CFM   8, 10
+CA3XRT                                          8, 11
+CA4XRT
+
+PA SERIES - Applied  TYPE     CFM RANGE         PAGE
+                     Indoor   1,500-6,600 CFM   12-13
+MODEL                Indoor   2,000-8,800 CFM   12, 14
+PA6X                 Indoor   2,250-9,900 CFM   12, 15
+PA8X                 Indoor   3,000-13,200 CFM  12, 16
+PA9X
+PA12X
+
+ABOUT RENEWAIRE                                   2-3
+SPECIFICATIONS & DIMENSIONS                      4-16
+CERTIFICATIONS & PERFORMANCE
+ORDERING & SUPPORT                                  18
+                                                19-20
+
+                              FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 1
+   ABOUT RENEWAIRE
+
+   R E N E WA I R E E R Vs
+
+   ACHIEVE SUSTAINABLE IAQ
+
+   RenewAire is a pioneer in enhancing IAQ while maximizing sustainability through enthalpic-core, static-plate Energy
+   Recovery Ventilators (ERVs) that optimize energy efficiency, lower costs by reducing HVAC loads and therefore
+   reduce environmental footprints. Our ERV technology preconditions incoming air with the otherwise-wasted energy
+   (heat and humidity) of the exhaust air going out—all while the airstreams are kept physically separate as certified by
+   the Air Conditioning, Heating and Refrigeration Institute (AHRI) for zero exhaust air transfer at normal balanced operating
+   conditions. As the pioneer of static-plate core technology in North America, RenewAire is the largest ERV producer in the USA.
+
+   OPTIMIZING                                               OA  COOLING SEASON    RA        OA  HEATING SEASON         RA
+   ENERGY EFFICIENCY
+                                                                       EFFICIENT                       EFFICIENT
+   Energy efficiency is optimized by preconditioning            HEAT & HUMIDITY                 HEAT & HUMIDITY
+   the outside air coming in with the otherwise-wasted
+   heat and humidity of the exhaust air going out. This                TRANSFER                        TRANSFER
+   exchange of energy moderates temperatures and moisture,
+   decreases HVAC equipment needs, drives operational       EA                    FA        EA                         FA
+   efficiencies and conserves energy.
+
+   REDUCING HVAC LOADS                                                                               INSIDE                  OUTSIDE
+                                                                                                Fresh Air Enters       Stale Room Air Exits
+   RenewAire technology reduces HVAC loads during both winter and summer. In turn,
+   HVAC equipment size and needs can be decreased and furnaces and air conditioners           Fixed Partition
+   can be smaller. This process ensures efficient operations and keeps both energy use and  and Spacer Plates
+   costs low, while at the same time maintaining high-level IAQ.
+                                                                                               (proprietary resin
+                                                                                            and composite media)       Outside Air
+
+                                                                                                       Stale Room Air
+
+   MINIMIZING ENVIRONMENTAL IMPACT
+
+   The combination of less energy used and HVAC loads being reduced conserves resources. Further, our Madison, WI plant
+   is 100% powered by renewable wind energy, and is one of the few buildings worldwide to be LEED and Green Globes
+   certified, as well as having achieved ENERGY STAR Building status. This commitment to sustainable manufacturing
+   minimizes our overall production and distribution environmental footprint.
+
+2
+                                                                                                                                                                                                    ABOUT RENEWAIRE
+
+WHY RENEWAIRE
+
+IS PREFERRED
+
+                  BEST VALUE
+
+                       u Priced competitively against other ERV models
+                       u Due to competitive pricing and decreased costs, payback is short and ROI is maximized
+                       u Contractors can pass these significant savings along to their customers
+
+                  RELIABLE OPERATION
+
+                       u Built-to-last ERVs have lifespans of 25+ years and operate consistently year-round in every extreme,
+                          including frost-free performance in all but the most severe winter climates
+
+                       u High-efficiency core operates dry in all conditions, meaning no condensate pans
+                       u An industry-leading ten-year warranty for the static-plate core, two-year warranty for commercial
+
+                          products and a five-year warranty for residential products
+                       u Superior product quality results in paramount reliability and longevity
+
+                  HIGHEST-QUALITY INDOOR AIR
+
+                       u Stale indoor air is replaced with fresh, conditioned and filtered air from
+                          the outside, resulting in Enhanced IAQ by removing harmful contaminants
+
+                       u Airstreams do not mix and pollutants are not transferred across partition plates
+                       u No biocide used; material does not promote biological growth
+                       u Moderated temperatures and humidity maintain a comfortable indoor environment
+
+                  OPTIMIZED ENERGY EFFICIENCY
+
+                       u Efficient heat and humidity transfer recaptures up to 70-80% of the energy exhausted in the airstream
+                       u Energy that’s otherwise wasted by conventional ventilation systems (such as bath fans) is reused,
+
+                          thus dramatically reducing monthly operation costs
+                       u Energy-efficient operation decreases HVAC loads, which cuts down on energy use and costs
+                       u The hotter or colder the climate, the more energy is recovered
+
+                  HIGHLY CERTIFIED
+
+                       u See individual catalog submittal for certification details:
+                                 u UL u cUL u ETL u HVI u AHRI
+
+                                                                                                                                                                                                                                     3
+                    SPECIFICATIONS & DIMENSIONS
+
+                    CA INDOOR Energy Recovery Module
+
+                    INDOOR UNIT                                                                                                                              SPECIFICATIONS
+                    Modular Cabinets
+
+                                                                                                                                                             Ventilation Type:                                                                           Insulation:
+                                                                                                                                                             Static plate, heat and humidity transfer                                                    One inch, high density, FSK faced, fiberglass
+
+                                                                                                                                                             Standard Features:                                                                          Options:
+                                                                                                                                                             Insulated sheet metal cabinets with energy                                                  Double wall construction
+                                                                                                                                                                                                                                                         Exterior paint - white, custom colors
+                                                                                                                                                                exchange cores and filters.
+                                                                                                                                                             Individual CA-Series units or stacks of units can be                                        Accessories:
+                                                                                                                                                                                                                                                         Filters - MERV 13, 2" (shipped loose)
+                                                                                                                                                                built into larger air handling systems.
+                                                                                                                                                             Blower not included and must be specified to meet
+
+                                                                                                                                                                job requirements.
+
+n5a.xlylssxis.xlsx                                                                          dP CCAh2aXrt‐4XITNhermal Performance Ratings G5 2015.2.xlsx                                                                                                              2 Cores (IOM)
+                                                                                                                                                                                                                                                                     CA3XIN
+                                                                                                                                                                   Description                                                                CA2XIN                                                   CA4XIN
+
+                    Download specification at:                                                                                                                     Typical Airflow                                           500-2,200                            750-3,300                             1,000-4,400
+                    renewaire.com/specifications                                                                                                                   Range CFM                                               Two L125-G5                         Three L125-G5                           Four L125-G5
+
+                                                                                                                                                                   AHRI 1060 Certified Core
+
+                                                                                                                                                                   Unit Dimensions                                         36" L x 42 1/2" W x 35" H 36" L x 62 1/4" W x 35" H 36" L x 81 3/4" W x 35" H
+                                                                                                                                                                   & Weight
+                                                                                                                                                                                                                           225-304 lbs.                              325-430 lbs.                      400-531 lbs.
+
+Applied Products                                                                                                                                                   Max. Shipping Dimensions 62" L x 42" W x 40" H                                              70" L x 47" W x 40" H          96" L x 47" W x 40" H
+                                                                                                                                                                                                                                                                       500 lbs.                       620 lbs.
+                                                                                                                                                                   & Weight (on pallet)                                                       350 lbs.
+
+Some                ventilation projects require more flexibility than                      sphaecektamgeedtaTlEhcRaeVbrsimnaelatlsolwwP.ietRhrefMF2oni0Eelrt"wRmexVArasi2r8:ne0Moc"oreEfxMfReR2VErsa"R8tbV:ino1tgh3s  G5  2015.2.xlsxTotal   qty.    4              To3taCl qotry.e6s (IOM)           Total qty. 8
+indoor              and outdoor cabinets of ERV cores in insulated
+
+filters. Realize your energy-efficiency goals with RenewAire’s Applied Products family of ERVs.
+
+• Cost effective energy recovery for virtually any air handling system
+
+• Complete flexibility in locating field supplied blowers                                                                                                                                                              CORE PERFORMANCE
+
+   A–IgRreFatLfoOr aWcousPticEaRllyFseOnsRitivMe aAppNlicCatiEons
+
+• AHRI certified performance data for efficiency and cross leakage
+
+•                   UL tested flammability and smoke                                  gfoeAArncieirorrfamfltloiomownwertch(i(aaCCtl amFFpeMpMelitc)s)ations
+                    NFPA 90A and 90B test standards
+                                                                                                                                                                                                                                                               Airflow (CFM)
+
+• Ten year core performance warranty                                                                                                                                                                                                               500         1000  1500                        2000
+                                                                                                                                                                                                                                              90%                                             3000 3500
+CA-Series           StSattiatcicPrPerseusruere   21..05                                                                                                                                                                    Effectiveness (%)
+                       DrDorpop(i(ni.n.w.wg.)g)                                                                                                                                                                                                                                                4000
+• Cores stacked side-by-1s.i5de horizontally                                                      Thermal Performance Ratings G5 2015.2.xlsx                                                                                                                         4 Cores (IOM)
+• Each cabinet contains 21, .30, or 4 energy exchange cores
+                                                                                                                                                                       70%
+• Indoor (IN) and outdoor1(.R0T) models available
+                                                 0.5
+• Indoor cabinets can be0s.t5acked up to five high (with support structure)
+                    accommodating up to 20,000 CFM (NOTE: outdoor cabinets cannot be stacked)                                                                                                                                                 50%
+
+•                   DSioduebaleccweaslsl csoenrvsitcruecdtiooo0n0r..0(o0sp) t00ional  1000  2000  3000                                                       4000                                                                                      CA2XIN
+•                                                                                     1000  2000  3000                                                       4000
+                                                                                                                                                                                                                                              30%
+
+PA-Series                                                Note: Airflow performance includes effect of clean,                                                                                                                                                    Airflow (CFM)
+                                                         standard filter supplied with unit.
+
+• Cores stacked vertically 3 or 4 cores high                                                                                                                                                                                                       500 1000 1500 2000 2500
+
+• Each cabinet contains 6, 8, 9, or 12 energy exchange cores                                                                                                                                                               Effectiveness (%)  90%
+
+• Indoor (IN) models only
+
+• Indoor cabinets can be joined together lengthwise to accommodate unlimited airflows                                                                                                                                                         70%
+
+• Top access service panels
+
+• Shipped knock down (K) or factory assembled (A)                                                                                                                                                                                             50%
+
+                    - Each component fits through 3 foot swing door. Ideal for tight applications.
+
+                    APPLICATION                          Installation Example                                                                                                                                                                          CA3XIN
+
+                      Central Air Handler using CA4X and exhaust and make-up air blowers.                                                                                                                                                     30%
+                    (CA-Series provide side service access and a “side-by-side” airflow arrangement.)
+                                                                                                                                                                                                                                                                Airflow (CFM)
+
+                                                                                            CA4X                                                                                                                                                  1000         2000  3000
+                                                                                                                                                                                                                                              90%
+                                                                                                                                                                                                                           Effectiveness (%)
+                                                                                                                                                                                                                                              70%
+
+                                             Similar designs can use PA-Series arrays.                                                                                                                                                        50%
+                          (PA-Series provide top service access and an “over-under” airflow arrangement.)
+                                                                                                                                                                                                                                                       CA4XIN
+66
+                                  (800) 627-4499 • Fax: (608) 221-2824                                                                                                                                                                        30%
+                                                                                                                                                                                                                                                    At AHRI 1060 standard conditions.
+                                                                                                                                                                                                                                                    See all AHRI certified ratings at www.ahrinet.org.
+
+     Specifications may be subject to change without notice.
+4 RENEWAIRE.COM 1.800.627.4499
+                                                                     CA2XIN Energy Recovery Module
+
+                                                                     Door                           33 7/8" Minimum                   35" Minimum                                            ABBREVIATION
+                                                                     Swing                          Service Area Typ.                    Service Area Typ.                                   EA: Exhaust Air to outside
+                                                                                                                                                                                             OA: Outside Air intake
+                                                                                                         Door                                                                                RA: Room Air to be exhausted
+                                                                                                         Swing                                                                               FA: Fresh Air to inside
+                                                                                                                                                                                             INSTALLATION ORIENTATION
+                                                                            TOP VIEW                                                                         36" Overall                     Unit may be installed in any
+                                                                                                                                                            34 7/8" Case                     orientation.
+                                                                            42 3/8" Overall                                                                                                  NOTE:
+                                                                                                                                                                                             1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                             DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                             NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                             2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                             TO CHANGE WITHOUT NOTICE.
+
+                                                                                                                                                                                         42 3/8" Case
+                                                                                                                                                                                                  5 3/4"
+                                                                                                                                                                                                    Typ.
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 5                                 34 7/8" Overall                                                                      1 1/8"
+                                                                                                                                                                                            Typ.
+                                                                                                                                                             Note: Pleated, disposable                                                  1 1/8"
+                                                                                                                                                             20" X 20" X 2" filters are                                                     Typ.
+                                                                                                                                                             provided for installation                                                          34 7/8" Case
+                                                                                                                                                             and are interchangeable             14 1/8" X 14 1/8"
+                                                                                                                                                             based on your airflow               Typ.
+                                                                                                                                                             path requirements. Filters
+                                                                                                                                                             are to be mounted           5 3/4"
+                                                                                                                                                             upstream to the core in     Typ.
+                                                                                                                                                             the direction of airflow
+                                                                                                             LEFT VIEW                                       entering the unit.          RIGHT VIEW
+                                                                     MAoIRdFeLl:OCWAC2OXNINFIGURATION
+                                                                     DAravaiwlabilne gas sThyowpnein:dUimnenitsioDn idmraweinng.sion                        FRONT VIEW                               UNIT MOUNTING & APPLICATION
+                                                                     Version: MAY16                                                                                                                  Can be mounted in any orientation. RA/EA airstream
+                                                                                                                                                                                                     can be switched with OA/FA airstream. Can be
+                                                                                                                       CA-SERIES                                                                     stacked three high.
+                                                                                                                                                                                                                                                                                                                                     SPECIFICATIONS & DIMENSIONS
+6 RENEWAIRE.COM 1.800.627.4499
+CA3XIN Energy Recovery Module
+
+Door                                                             33 7/8" Minimum    35" Minimum                                                                         ABBREVIATION
+Swing                                                            Service Area Typ.     Service Area Typ.                                                                EA: Exhaust Air to outside
+                                                                                                                                                                        OA: Outside Air intake
+                                                                       Door                                                                                             RA: Room Air to be exhausted
+                                                                       Swing                                                                                            FA: Fresh Air to inside
+                                                                                                                                                                        INSTALLATION ORIENTATION
+       TOP VIEW                                                                      36" Overall                                                                        Unit may be installed in any
+                                                                                    34 3/4" Case                                                                        orientation.
+         62" Overall                                                                                                                                                    NOTE:
+                                                                                                                                                                        1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                        DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                        NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                        2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                        TO CHANGE WITHOUT NOTICE.
+
+                                                                                                                                                                        62" Case
+                                                                                                                                                                                       5 3/4"
+                                                                                                                                                                                       Typ.
+
+                                                                 34 7/8" Overall                                                                                                           1 1/8"
+                                                                                                                                                      1 1/8"                                  Typ.
+                                                                                                                                                          Typ.
+                                                                                                                                                                                                   34 7/8" Case
+
+                                                                                    Note: Pleated, disposable                                                   5 3/4"  14 1/8" X 24 1/8"
+                                                                                    20" X 20" X 2" filters are                                                  Typ.    Typ.
+                                                                                    provided for installation
+                                        LEFT VIEW                                   and are interchangeable                                                     RIGHT VIEW
+MAoIRdFeLl:OCWAC3OXNINFIGURATION                                                    based on your airflow path
+DAravaiwlabilne gas sThyowpnein:dUimnenitsioDn idmraweinng.sion                     requirements. Filters are to                                                              UNIT MOUNTING & APPLICATION
+Version: MAY16                                                                      be mounted upstream to                                                                    Can be mounted in any orientation. RA/EA airstream
+                                                                                    the core in the direction of                                                              can be switched with OA/FA airstream. Can be
+                                                                                    airflow entering the unit.                                                                stacked three high.
+
+                                                                                    FRONT VIEW
+                                                                     CA4XIN Energy Recovery Module
+
+                                                                             33 7/8" Minimum                                          35" Minimum                                                     ABBREVIATION
+                                                                            Service Area Typ.                                            Service Area Typ.                                            EA: Exhaust Air to outside
+                                                                                                                                                                                                      OA: Outside Air intake
+                                                                     Door                                     Door                                                                                    RA: Room Air to be exhausted
+                                                                     Swing                                    Swing                                                                                   FA: Fresh Air to inside
+                                                                                                                                                                                                      INSTALLATION ORIENTATION
+                                                                                                                                                                                                      Unit may be installed in any
+                                                                                                                                                                                                      orientation.
+                                                                                                                                                                                                      NOTE:
+                                                                                                                                                                                                      1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                      DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                      NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                      2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                      TO CHANGE WITHOUT NOTICE.
+
+                                                                            TOP VIEW
+
+                                                                            81 5/8" Overall                                                                    36"                                    81 5/8" Case
+                                                                                                                                                            Overall                                             7 5/8" Typ.
+
+                                                                                                                                                            34 7/8"
+                                                                                                                                                             Case
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 7                                 34 7/8" Overall                                                                          34 7/8"                             1 1/8" Typ.
+                                                                                                                                                                                                Case
+
+                                                                                                                                                               Note: Pleated, disposable     1 1/8"   7 5/8"  14 1/8" X 32 1/8"
+                                                                                                                                                               20" X 20" X 2" filters are       Typ.  Typ.    Typ.
+                                                                                                                                                               provided for installation
+                                                                                                              LEFT VIEW                                        and are interchangeable                RIGHT VIEW
+                                                                     MAoIRdFeLl:OCWAC4OXNINFIGURATION                                                          based on your airflow path
+                                                                     DAravaiwlabilne gas sThyowpnein:dUimnenitsioDn idmraweinng.sion                           requirements. Filters are to                 UNIT MOUNTING & APPLICATION
+                                                                     Version: MAY16                                                                            be mounted upstream to                       Can be mounted in any orientation. RA/EA airstream
+                                                                                                                                                               the core in the direction of                 can be switched with OA/FA airstream. Can be
+                                                                                                                       CA-SERIES                               airflow entering the unit.                   stacked three high.
+
+                                                                                                                                                            FRONT VIEW
+         SPECIFICATIONS & DIMENSIONS
+
+         CA OUTDOOR Energy Recovery Module
+
+         ROOFTOP UNITS                                                                         SPECIFICATIONS
+         Modular Cabinets
+                                                                                               Ventilation Type:
+                                                                                               Static plate, heat and humidity transfer                                    Insulation:
+                                                                                                                                                                           One inch, high density, FSK faced, fiberglass
+                                                                                               Standard Features:
+                                                                                               Insulated sheet metal cabinets with energy                                  Options:
+                                                                                                                                                                           Double wall construction
+                                                                                                  exchange cores and filters.                                               Exterior paint - white, custom colors
+                                                                                               Blower not included and must be specified to
+                                                                                                                                                                           Accessories:
+                                                                                                  meet job requirements.                                                   Roof curb - standard 14"
+                                                                                                                                                                           Filters - MERV 13, 2" (shipped loose)
+
+xs.xlsx                                        Thermal PerfoCrhmaratCnhcaerRt atings G5 2015.2.xlsx Description                          2 CoresCA(I2OXMRT)                        CA3XRT                   CA4XRT
+
+                                                                                               Typical Airflow                                   500-2,200                         750-3,300               1,000-4,400
+                                                                                               Range CFM
+                                                                                                                                               Two L125-G5                     Three L125-G5             Four L125-G5
+         Download specification at:                                                            AHRI 1060 Certified Core                   55 1/2" L x 43 1/4" W x           55 1/2" L x 63 1/2" W x  55 1/2" L x 83 1/4" W x
+         renewaire.com/specifications
+                                                                                               Unit Dimensions                                   42 1/4" H                        42 1/2" H                42 1/4" H
+                                                                                               & Weight                                        250-329 lbs.                      377-482 lbs.             462-593 lbs.
+                                                                                                                                         63" L x 47" W x 48" H             60" L x 90" W x 48" H    60" L x 90" W x 48" H
+                                                                                                         Max. Shipping Dimensions
+                                                                                                         & Weight (on pallet)                     400 lbs.                         590 lbs.                 700 lbs.
+
+                                                                                                         Filters: MERV 8:                       Total qty. 4                      Total qty. 6             Total qty. 8
+                                               Thermal Performance Ratings G5 2015.2.xls2x0" x 20" x 2"                                  3 Cores (IOM)
+
+         AIRFLOW PERFORMANCE                                                                   CORE PERFORMANCE
+
+                                               AirfloAwirf(loCwFM(C)FM)                                                            Airflow (CFM)
+
+         Static Presure               2.0 2.0                                                                          500         1000  1500              2000
+            StDartiocp (Pirne.swu.rge)1.5 1.5                                                                     90%                                   3000 3500
+                 Drop (in.w.g)                                                                 Effectiveness (%)
+                                      1.0 1.0 Thermal Performance Ratings G5 2015.2.xlsx 70%                                             4 Cores (IOM)
+
+                                      0.5 0.5                                                                     50%
+
+                                      0.0 0.0                                                                              CA2XRT
+                                           0 0 1000 10002000 20003000 30004000 4000
+                                           Note: Airflow performance includes effect of clean,                     30%
+                                           standard filter supplied with unit.
+                                                                                                                                    Airflow (CFM)
+
+                                                                                               Effectiveness (%)       500 1000 1500 2000 2500
+                                                                                                                  90%
+
+                                                                                                                  70%
+
+                                                                                                                  50%
+
+                                                                                                                           CA3XRT
+
+                                                                                                                  30%
+
+                                                                                                                                   Airflow (CFM)
+
+                                                                                                                      1000  2000         3000           4000
+                                                                                                                  90%
+                                                                                               Effectiveness (%)
+                                                                                                                  70%
+
+                                                                                                                  50%
+
+                                                                                                                           CA4XRT
+
+                                                                                                                  30%
+                                                                                                                        At AHRI 1060 standard conditions.
+                                                                                                                        See all AHRI certified ratings at www.ahrinet.org.
+
+              Specifications may be subject to change without notice.
+         8 RENEWAIRE.COM 1.800.627.4499
+                                                                     CA2XRT Energy Recovery Module
+
+                                                                                                              Alternate Hood Location.                                                       CURB CA2XRT                                                           ABBREVIATIONS
+                                                                                                              If hood location switched,                                                                                                                           EA: Exhaust Air to outside
+                                                                                                              plug existing mounting holes                                                                                                                         OA: Outside Air intake
+                                                                                                              on opposite side of unit to                                                                                                                          RA: Room Air to be exhausted
+                                                                                                              prevent leakage.                                                                                                                                     FA: Fresh Air to inside
+                                                                                                                                                                                                                                                                   INSTALLATION ORIENTATION
+                                                                             24" X 10"                        CL 20 1/4"       33 7/8" Minimum                                               37 5/8" O.D.                                                          Unit must be installed in orientation
+                                                                     Floor Opening                               Typ.            Service Area                                                                                                                      shown.
+                                                                                                                                                                                A                            A                                                     NOTE
+                                                                                   Typ.                                                                                                                                                                            1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                                   DIMENSIONS ARE ROUNDED TO THE
+                                                                     55 1/2" Overall                                           4"Door                                                        FA                                  28 7/8" I.D.                      NEAREST EIGHTH OF AN INCH.
+                                                                         35 1/2" Case                                             Typ.Swing                                                                                                                        2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                       CL 25 7/8"                                                                                                                                                                  TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                           35 1/2" Minimum
+                                                                                                                                                               Service Area                  RA                                                CURB CROSS-SECTION A-A (TYP.)
+                                                                                                                                                                               32 5/8" O.D.
+                                                                                                                                                                     5 3/4"                                  1 7/8"                            1 1/2" X 1/4"                1 7/8"
+                                                                                                                                                                                                                   12 5/8" I.D.                Neoprene Gasket
+                                                                                                   CL 9 1/2"                                                                                   26 1/4" I.D.
+                                                                                                                                                                                               33 7/8" I.D.                                    3/4" X 3 1/2"                                             14"
+                                                                                                                                                                                                                                               Wooden Nailer
+                                                                                                                                                                                             TOP VIEW
+                                                                                                              TOP VIEW                                                                                                                                                                         3"
+
+                                                                                                              43 1/4" Overall                                                                                                                                      SECTION A-A
+                                                                                                               41 3/4" Case
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 9                                                               2"                                  OA Hood can be           35 3/4"                                                             24 1/8"
+                                                                                                                   37 5/8"     Typ.                                  mounted to either       Lifting Lugs                                                           Typ.
+                                                                                                                Lifting Lugs
+                                                                                                                                                                               side of unit
+
+                                                                                                                                                                                                                                               42 1/4" Overall              25 1/4" 10"            Typ.
+                                                                                                                                                                                                                                                     39 1/8" Case
+                                                                                                                                                                     Pressure Ports                                                                                                                Typ.
+                                                                                                                                                                             (4) Typ.
+
+                                                                                      8 1/8"                                                                                                 Note: Pleated, disposable 20" X 20" X                                 Lower side pan inlets/outlets
+                                                                                        Typ.                                                                                                 2" filters are provided for installation                              are patched with
+                                                                                                Floor pan inlets/outlets are open by                                                         and are interchangeable based on                                      removable insulated pans.
+                                                                                                default; These can be patched from                                                           your airflow path requirements. Filters
+                                                                                                inside the unit with removeable insulated                                                    are to be mounted upstream to the                                       RIGHT VIEW
+                                                                                                pans from the side openings, if unused.                                                      core in the direction of airflow
+                                                                                                                                                                                             entering the unit.                                                                 UNIT MOUNTING & APPLICATION
+                                                                                               LEFT VIEW                                                                                                                                                                        Must be mounted as shown. Duct configuration is
+                                                                                                                                                                                                 FRONT VIEW                                                                     field convertible. Weather hood can be moved in
+                                                                     DMroaAAvdwIaRielaiFnbl:LlgeCOaTsAWys2hpoCXewROn: TiUNn ndFimiItGeDnUsiimRonAedTrnaIwOsiinoNgn.                                                                                                             the field. RA/EA airstream can be switched with
+                                                                     Version: MAY16                                                                                                                                                                                             OA/FA airstream.
+
+                                                                                                                                                                     CA-SERIES
+                                                                                                                                                                                                                                                                                                                                     SPECIFICATIONS & DIMENSIONS
+10 RENEWAIRE.COM 1.800.627.4499
+CA3XRT Energy Recovery Module
+
+                                                              Alternate Hood Location. If hood location                                                                        ABBREVIATIONS
+                                                              switched, plug existing mounting holes on                                                                        EA: Exhaust Air to outside
+                                                              opposite side of unit to prevent leakage.                                                                        OA: Outside Air intake
+                                                                                                                                                                               RA: Room Air to be exhausted
+                 36" X 10"                                                                                                       CURB CA3XRT                                   FA: Fresh Air to inside
+                       Floor                                                                                                                                                   INSTALLATION ORIENTATION
+                                                  CL 30 1/4"            33 3/4" Minimum                                          57 1/2" O.D.                                  Unit must be installed in orientation
+                 Opening                             Typ.                 Service Area                                                                                         shown.
+                        Typ.                                                                                                     53 3/4" I.D.                                  NOTE
+                                                                                                                                                                               1. UNLESS OTHERWISE SPECIFIED,
+                                                                        5"                                                    A                             A                  DIMENSIONS ARE ROUNDED TO THE
+                                                                           Typ.                                                                                                NEAREST EIGHTH OF AN INCH.
+                 35 1/2" Case                                           Door                                                                   FA              28 7/8" I.D.    2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                     35 1/2" MinimumSwing                                                      TO CHANGE WITHOUT NOTICE.
+55 1/2" Overall                CL 26"                                                                   Service Area
+                                                                                                                32 5/8"                        RA
+                                                                                                                   O.D.
+                                                                                                                                                                               CURB CROSS-SECTION A-A (TYP.)
+
+                                       CL 9 1/2"                                                                      9 5/8"     38 1/4" I.D.               12 3/8"            1 1/2" X 1/4"                1 7/8"
+                                                                                                                                                               I.D.            Neoprene Gasket
+
+                                                                                                                                                                    1 7/8"
+
+                                                                                                                                 TOP VIEW                                      3/4" X 3 1/2"                              14"
+                                                                                                                                                                               Wooden Nailer
+                                                  TOP VIEW
+                                                                                                                                                                                                        3"
+
+                                                                                                                                                                                        SECTION A-A
+
+                                                  63 3/8" Overall
+
+                                  2"              61 1/2" Case                                 OA Hood can be                      35 3/4"                                     36 1/8" Typ.                 10" Typ.
+                               Typ.                                                           mounted to either                  Lifting Lugs
+                                                  57 5/8" Lifting Lugs
+                                                                                                        side of unit
+
+                                                                                              Pressure Ports                                                42 1/4" Overall                                 24 7/8" Typ.
+                                                                                                      (4) Typ.                                                   39 1/4" Case
+
+                        12"                                                                                      Note: Pleated, disposable 20" X 20" X 2"                      Lower side pan inlets/outlets
+                       Typ.                                                                                      filters are provided for installation and                     are patched with
+                                                                                                                 are interchangeable based on your                             removable insulated pans.
+                                    Floor pan inlets/outlets are open by                                         airflow path requirements. Filters are
+                                    default; These can be patched from                                           to be mounted upstream to the core                                 RIGHT VIEW
+                                    inside the unit with removeable insulated                                    in the direction of airflow entering the
+                                    pans from the side openings, if unused.                                      unit.                                                                             UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                                   Must be mounted as shown. Duct configuration is
+                               LEFT VIEW                                                                         FRONT VIEW                                                                        field convertible. Weather hood can be moved in
+                                                                                                                                                                                                   the field. RA/EA airstream can be switched with
+MDroadwAAeviInalR:ilgaFCbLlTeAyOa3psWXsehRo:CTwUOnniNnitdFiDmIGiemnUsieRonnAdsTriaoIwOninNg.                                                                                                       OA/FA airstream.
+Version: MAY16
+                                                                      CA4XRT Energy Recovery Module
+
+                                                                               48" X 10"                   Alternate Hood Location. If hood location                                                                                                                            ABBREVIATIONS
+                                                                      Floor Openings                       switched, plug existing mounting holes on                                                                                                                            EA: Exhaust Air to outside
+                                                                                                           opposite side of unit to prevent leakage.                                                                                                                            OA: Outside Air intake
+                                                                                      Typ.                                                                                                                                                                                      RA: Room Air to be exhausted
+                                                                                                                                                                                                                                                                                FA: Fresh Air to inside
+
+                                                                                               CL 40 1/8"                                   33 7/8" Minimum  35 1/2" Minimum         CURB CA4XRT                                                              1 7/8"            INSTALLATION ORIENTATION
+                                                                                                  Typ.                                        Service Area      Service Area                                                                                                    Unit must be installed in orientation
+                                                                                                                                                                            12 5/8"          50 1/2" I.D.                                                                       shown.
+                                                                                                                                                                               I.D.
+                                                                      35 1/2" Case                                                          Door                                               FA                                                             28 7/8" I.D.      NOTE
+                                                                           CL 26"                                                                                                              RA                                                                 32 5/8" O.D.  1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                                                DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                                                NEAREST EIGHTH OF AN INCH.
+
+                                                                                                                                            Swing            A                                             A                                                                    2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                                                TO CHANGE WITHOUT NOTICE.
+
+                                                                                    CL 9 1/2"                                                                                                                 13 3/8" CURB CROSS-SECTION A-A (TYP.)
+
+                                                                                                                                                                                      73 3/8" I.D.                                                                              1 1/2" X 1/4"    1 7/8"
+                                                                                                                                                                                     77 1/8" O.D.
+                                                                                                                                                                                                                                                                                Neoprene Gasket
+                                                                                                                                                                             TOP VIEW
+                                                                                                                                                                                                                                                                                3/4" X 3 1/2"                   14"
+                                                                                                                                                                OA Hood can be                                                                                                  Wooden Nailer
+                                                                                               TOP VIEW                                                         mounted to either
+                                                                                                                                                                side of unit
+                                                                                                                                                                                                                                                                                                            3"
+                                                                                                                                                                  55 1/2" Overall
+                                                                                                                                                                               30 5/8"                                                                                          SECTION A-A
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 11                                83" Overall                                2"                           Lifting Lugs                                                                                        48 1/8" Typ.                    10" Typ.
+                                                                                                   81 3/8" Case                             Typ.
+                                                                                               77 1/4" Lifting Lugs
+
+                                                                                                                                          5 7/8"                                                                                                                                                                24 7/8" Typ.
+                                                                                                                                             Typ.
+                                                                                                                                                                                                                                          42 1/8" Overall
+                                                                                                                                                                                                                                                39 1/4" Case
+                                                                                    16"                                                            Pressure Ports                                                                                                               Lower side pan inlets/outlets
+                                                                                  Typ.                                                                     (4) Typ.                                                                                                             are patched with
+                                                                                                                                                                                                                                                                                removable insulated pans.
+                                                                                                 Floor pan inlets/outlets are open by                                   Note: Pleated, disposable
+                                                                                                 default; These can be patched from                                     20" X 20" X 2" filters are                                                                                RIGHT VIEW
+                                                                                                 inside the unit with removeable insulated                              provided for installation and
+                                                                                                 pans from the side openings, if unused.                                are interchangeable based                                                                                           UNIT MOUNTING & APPLICATION
+                                                                                                                                                                        on your airflow path                                                                                                Must be mounted as shown. Duct configuration is
+                                                                                                 LEFT VIEW                                                              requirements. Filters are to                                                                                        field convertible. Weather hood can be moved in
+                                                                                                                                                                        be mounted upstream to                                                                                              the field. RA/EA airstream can be switched with
+                                                                          AIRFLOW CONFIGURATION                                                                         the core in the direction of                                                                                        OA/FA airstream.
+                                                                                                                                                                        airflow entering the unit.
+                                                                      MoAdvaeilalb:leCaAs s4hXowRnTin dimension drawing.
+                                                                      Drawing Type: Unit Dimension                                                                  FRONT VIEW
+                                                                      Version: MAY16
+
+                                                                                                                                            CA-SERIES
+               SPECIFICATIONS & DIMENSIONS
+
+               PA SERIES Energy Recovery Module
+
+               INDOOR UNIT                                                                SPECIFICATIONS
+               Unlimited Modular Panels
+
+                                                                                          Ventilation Type:                                           Insulation:
+                                                                                          Static plate, heat and humidity transfer                    One inch, high density, FSK faced, fiberglass
+
+                                                                                          Standard Features:                                          Options:
+                                                                                          Insulated sheet metal panels easily slide into              Knockdown
+                                                                                                                                                      Assembled on structural forklift base
+                                                                                             receivers to enclose stacks of energy exchange
+                                                                                             cores using unique patented design, US Patent            Accessories:
+                                                                                             5,660,228                                                Filters - MERV 13, 2" (shipped loose)
+                                                                                          Individual PA-Series units can be joined together to
+As.Rxl.sxxlsx                                               Catalog CChhaarrtt               provide unlimited airflow capacities for larger air
+                                                                                             handling systems.
+                                                                                          Blower not included and must be specified to meet
+                                                                                             job requirements.
+
+                                                                                          Description              PA6X                               PA8X            PA9X                  PA12X
+
+                                                                                          Typical Airflow           1,500-6,600                   2,000-8,800          2,250-9,900          3,000-13,200
+                                                                                          Range CFM
+
+                                                                                          AHRI 1060                   Six                          Eight                Nine                Twelve
+                                                                                          Certified Core            L125-G5                       L125-G5              L125-G5              L125-G5
+
+                                                                                          Unit Dimensions     73 1/2" L x 37 1/4" W 73 1/2" L x 37 1/4" W 109 1/2" L x 37 1/4" W 109 1/2" L x 37 1/4" W
+                                                                                          & Weight
+                                                                                                                   x 66 1/4" H                   x 86" H              x 66 1/4" H           x 86" H
+
+               Download specification at:                                                                          522-565 lbs.                  650-700 lbs.         740-910 lbs.         936-1,000 lbs.
+               renewaire.com/specifications
+                                                                                          Max. Shipping
+
+                                                                                          Dimensions & 96" L x 47" W x 75" H 96" L x 47" W x 92" H 124" L x 48" W x 75" H 124" L x 48" W x 95" H
+
+                                                                                          Weight (on pallet,       700 lbs.                      850 lbs.             1,100 lbs.           1,200 lbs.
+
+                                                                                          assembled only)
+
+                                                                                          Filters MERV 8:          Total qty. 12                 Total qty. 16        Total qty. 18        Total qty. 24
+                                                                                          20" x 20" x 2"
+
+               AIRFLOW PERFORMANCE
+Ratings G5 2015.2.xlsx                                            6 Cores (IOThMe)rmal Performance Ratings G5 2015.2.xlsx                                       9 Cores (IOM)
+
+               2.5                                       AirfloAwirf(lCowFM(C) FM)
+
+               Static Pressure                      2.0
+                  StaDtriocpP(rien.suw.rge.)2.0
+                       Drop (in.w.g)
+                                                    1.5
+                                            1.5
+
+                                            1.0 1.0
+
+                                            0.5 0.5
+
+Ratings G5 2015.2.xlsx0.0 0.0                                     8 Cores (IOThMe)rmal Performance Ratings G5 2015.2.xlsx                                       12 Cores (IOM)
+
+                                              0 0 3000 10006000 2000 90003000120040000
+
+               Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+               CORE PERFORMANCE
+
+                                                              Airflow (CFM)                                                                           Airflow (CFM)
+
+               Effectiveness (%)                 1000 2000 3000 4000 5000 6000 7000                                                        1500       3500      5500  7500           9500
+                                            90%                                                                                       90%
+                                                                                                                   Effectiveness (%)
+                                            70%                                                                                       70%
+
+                                            50%                                                                                       50%
+
+                                                      PA6X                                                                                     PA9X
+
+                                            30%                                                                                       30%
+
+                                                            Airflow (CFM)                                                                             Airflow (CFM)
+
+                                                 2000       4000  6000              8000                                                  3000        6000      9000  12000          15000
+                                            90%                                                                                       90%
+               Effectiveness (%)                                                                                   Effectiveness (%)
+                                            70%                                                                                       70%
+
+                         50%                                                                                                          50%
+
+                              PA8X                                                                                                             PA12X
+
+                         30%                                                                                                          30%
+                              At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+      Specifications may be subject to change without notice.
+
+12 RENEWAIRE.COM 1.800.627.4499
+                                                                      PA6X Energy Recovery Module                                                                                                                                                                                 ABBREVIATION
+                                                                                                                                                                                                                                                                                  EA: Exhaust Air to outside
+                                                                                                                                                          Filters to be placed on the                                                                                             OA: Outside Air intake
+                                                                                                                                                          upstream side of the cores,                                                                                             RA: Room Air to be exhausted
+                                                                                                                                                          depending on airflow                                                                                                    FA: Fresh Air to inside
+                                                                                                                                                          arrangement chosen.                                                                                                     INSTALLATION ORIENTATION
+                                                                                                                                                          Filters are 2" X 20" X 20"                                                                                              Unit must be installed in orientation
+                                                                                                                                                          pleated disposable.                                                                                                     shown.
+                                                                      73 3/8" Overall                                                                                                                                                                                             NOTE:
+                                                                                                                 73 1/8" Case                                                                                                                                                     1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                                                  DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                                                  NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                                                  2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                                                  TO CHANGE WITHOUT NOTICE.
+
+                                                                                                    TOP VIEW                                                                           71 5/8" Minimum                                                                            AVAILABLE AIRFLOW
+                                                                                                                                                                                         Service Area                                                                               ARRANGEMENTS
+                                                                                                    37 1/4" Overall                                                                                                                                                                     (SIDE VIEW)
+                                                                                                        35" Case
+                                                                                                                                                                                                                                                                                                                      2
+
+                                                                                                                                                                                                                                                                               1                 2  1                 2
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 13                                                                                                                                                                                                           2  1                 2                 1
+
+                                                                                                                                                                                                                                   22 1/2" Minimum                                Arrangement 1        Arrangement 2
+                                                                                                                                                                                                                                      Service Area
+                                                                                                                                     66 1/8" Overall                                                                                                                           1  1                 1                 1
+                                                                                                                                          59 3/4" Case
+                                                                                                                                                                                                                                   28" Typ.  34 3/8" Typ.                      2                 2  2                 2
+
+                                                                                                                                                                                                                                                                                  Arrangement 3        Arrangement 4
+
+                                                                                                                                                                                                                                   5"                                             Performance Derating:
+
+                                                                                                                                                                                                                                                                 Airflow Arrangements 3 & 4 result in lower energy transfer.
+
+                                                                                                                                                                                                                                                                 Reduce sensible effectiveness by 2 percentage points.
+
+                                                                                                    LEFT VIEW                  PAIN                            PAIN FRONT VIEW PAIN                                                                        PAIN                Reduce total effectiveness by 1 percentage point.
+
+                                                                      AIRFLOW CONFIGURATION                                    1                               2                                        3                                                  4                                        UNIT MOUNTING & APPLICATION
+
+                                                                      MoAdvaeilalb:lePaAs s6hoXwn:                   RA/OA           RA/OA              RA/OA               EA/FA      RA/OA                         EA/FA         RA/OA                               EA/FA                        Must be mounted as shown. RA/EA airstream can
+                                                                                                                                                                            EA/FA                                                  RA/OA                                EA/FA                       be switched with OA/FA airstream. Knockdown can
+                                                                      Drawing Type: Unit Dimension EA/FA                             EA/FA              RA/OA                          EA/FA                                RA/OA                                                                   be field assembled for multiple duct configurations.
+                                                                                                                                                                                                                                                                                                    Multiple cabinets can be aligned for unlimited airflow.
+                                                                      Version: AUG18
+
+                                                                                                                     PA-SERIES
+                                                                                                                                                                                                                                                                                                                                     SPECIFICATIONS & DIMENSIONS
+14 RENEWAIRE.COM 1.800.627.4499
+PA8X Energy Recovery Module                                                                                                                                                                       ABBREVIATION
+                                                                                                                                                                                                  EA: Exhaust Air to outside
+                                                                                    Filters to be placed on the                                                                                   OA: Outside Air intake
+                                                                                    upstream side of the cores,                                                                                   RA: Room Air to be exhausted
+                                                                                    depending on airflow                                                                                          FA: Fresh Air to inside
+                                                                                    arrangement chosen.                                                                                           INSTALLATION ORIENTATION
+                                                                                    Filters are 2" X 20" X 20"                                                                                    Unit must be installed in orientation
+                                                                                    pleated disposable.                                                                                           shown.
+73 3/8" Overall                                                                                                                                                                                   NOTE:
+                                       73 1/8" Case                                                                                                                                               1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                  DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                  NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                  2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                  TO CHANGE WITHOUT NOTICE.
+
+                              TOP VIEW                                               71 5/8" Minimum                                                                                              AVAILABLE AIRFLOW
+                                                                                       Service Area                                                                                                 ARRANGEMENTS
+                              37 1/4" Overall                                                                                                                                                           (SIDE VIEW)
+                                  35" Case
+                                                                                                                                                                                               1                 2  1                 2
+
+                                                                                                                        22 1/2" Minimum                                                        2                 1  2                 1
+                                                                                                                           Service Area
+                                                            85 7/8" Overall                                                                                                                       Arrangement 1        Arrangement 2
+                                                                79 1/2" Case
+                                                                                                                                                                                               1                 1  1                 1
+
+                                                                                                                                            37" Typ.  45 1/8" Typ.                             2                 2  2                 2
+
+                                                                                                                                                                                                  Arrangement 3        Arrangement 4
+
+                                                                                                                                            5"                                                    Performance Derating:
+
+                                                                                                                                                                                 Airflow Arrangements 3 & 4 result in lower energy transfer.
+
+                                                                                                                                                                                 Reduce sensible effectiveness by 2 percentage points.
+
+                              LEFT VIEW               PAIN                           PAFINRONT VIEW PAIN                                                                   PAIN                Reduce total effectiveness by 1 percentage point.
+
+AIRFLOW CONFIGURATION                                 1                              2                                  3                                                  4                                        UNIT MOUNTING & APPLICATION
+
+MoAdvaeilalb:lePaAs s8hoXwn:                   RA/OA        RA/OA             RA/OA               EA/FA          RA/OA               EA/FA                          RA/OA              EA/FA                        Must be mounted as shown. RA/EA airstream can
+                                                                                                  EA/FA                                                             RA/OA               EA/FA                       be switched with OA/FA airstream. Knockdown can
+Drawing Type: Unit Dimension EA/FA                          EA/FA             RA/OA                              EA/FA                      RA/OA                                                                   be field assembled for multiple duct configurations.
+                                                                                                                                                                                                                    Multiple cabinets can be aligned for unlimited airflow.
+Version: AUG18
+                                                                      PA9X Energy Recovery Module                                                                                                                                                                             ABBREVIATION
+                                                                                                                                                                                                                                                                              EA: Exhaust Air to outside
+                                                                                                                                            Filters to be placed on the                                                                                                       OA: Outside Air intake
+                                                                                                                                            upstream side of the cores,                                                                                                       RA: Room Air to be exhausted
+                                                                                                                                            depending on airflow                                                                                                              FA: Fresh Air to inside
+                                                                                                                                            arrangement chosen.                                                                                                               INSTALLATION ORIENTATION
+                                                                                                                                            Filters are 2" X 20" X 20"                                                                                                        Unit must be installed in orientation
+                                                                                                                                            pleated disposable.                                                                                                               shown.
+                                                                      109 3/8" Overall                                                                                                                                                                                        NOTE:
+                                                                                                            109 1/4" Case                                                                                                                                                     1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                                              DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                                              NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                                              2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                                              TO CHANGE WITHOUT NOTICE.
+
+                                                                      TOP VIEW                                                                                                                                                                                                AVAILABLE AIRFLOW
+                                                                                                                                                                                                                                                                                ARRANGEMENTS
+                                                                           37 1/4"                                                                                                                                                                                                  (SIDE VIEW)
+                                                                          Overall
+                                                                         35" Case                                                                                        107 3/4" Minimum                                                                                  1                 2  1                 2
+                                                                                                                                                                            Service Area
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 15                                                                                                                                                                                                       2  1                 2                 1
+
+                                                                                                                                                                                                                               31 1/8"                                        Arrangement 1        Arrangement 2
+                                                                                                                                                                                                                                  Minimum
+                                                                                                                           66 1/8" Overall                                                                                                                                 1  1                 1                 1
+                                                                                                                                59 3/4" Case                                                                                          Service
+                                                                                                                                                                                                                                         Area
+
+                                                                                                                                                                                                                               5"                                          2                 2  2                 2
+                                                                                                                                                                                                                                    28" Typ.
+                                                                                                                                                                                                                                                                              Arrangement 3        Arrangement 4
+                                                                                                                                                                                                                                         34 3/8" Typ.
+                                                                                                                                                                                                                                                                              Performance Derating:
+
+                                                                                                                                                                                                                                                             Airflow Arrangements 3 & 4 result in lower energy transfer.
+
+                                                                                                                                                                                                                                                             Reduce sensible effectiveness by 2 percentage points.
+
+                                                                      LEFT VIEW                                                               PAIN                       FRPOAINNT VIEW             PAIN                                               PAIN                Reduce total effectiveness by 1 percentage point.
+
+                                                                      AIRFLOW CONFIGURATION                                                   1                          2                          3                                                  4                                        UNIT MOUNTING & APPLICATION
+
+                                                                      MoAdvaeilalb:lePaAs s9hoXwn:                         RA/OA                    RA/OA  RA/OA                      EA/FA  RA/OA               EA/FA         RA/OA                               EA/FA                        Must be mounted as shown. RA/EA airstream can
+                                                                                                                                                                                      EA/FA                                    RA/OA                                EA/FA                       be switched with OA/FA airstream. Knockdown can
+                                                                      Drawing Type: Unit Dimension EA/FA                                            EA/FA  RA/OA                             EA/FA                      RA/OA                                                                   be field assembled for multiple duct configurations.
+                                                                                                                                                                                                                                                                                                Multiple cabinets can be aligned for unlimited airflow.
+                                                                      Version: AUG18
+
+                                                                                                                           PA-SERIES
+                                                                                                                                                                                                                                                                                                                                     SPECIFICATIONS & DIMENSIONS
+16 RENEWAIRE.COM 1.800.627.4499
+PA12X Energy Recovery Module                                                                                                                                                                                  ABBREVIATION
+                                                                                                                                                                                                              EA: Exhaust Air to outside
+                                                                   Filters to be placed on the                                                                                                                OA: Outside Air intake
+                                                                   upstream side of the cores,                                                                                                                RA: Room Air to be exhausted
+                                                                   depending on airflow                                                                                                                       FA: Fresh Air to inside
+                                                                   arrangement chosen.                                                                                                                        INSTALLATION ORIENTATION
+                                                                   Filters are 2" X 20" X 20"                                                                                                                 Unit must be installed in orientation
+                                                                   pleated disposable.                                                                                                                        shown.
+109 3/8" Overall                                                                                                                                                                                              NOTE:
+                                   109 1/4" Case                                                                                                                                                              1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                              DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                              NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                              2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                              TO CHANGE WITHOUT NOTICE.
+
+TOP VIEW                                                                                                                                                                                                      AVAILABLE AIRFLOW
+                                                                                                                                                                                                                ARRANGEMENTS
+     37 1/4"                                                                                                                                                                                                        (SIDE VIEW)
+    Overall
+   35" Case                                                                                                      107 3/4" Minimum                                                         1                                  2  1                 2
+                                                                                                                    Service Area
+
+                                                                                                                                                                                          2                                  1  2                 1
+
+                                                                                                                                                         22 1/2"                                              Arrangement 1        Arrangement 2
+                                                                                                                                                            Minimum
+
+                                                                                                                                                                Service
+                                                                                                                                                                   Area
+
+                                                                            85 7/8" Overall                                                                                               1                   1                 1                 1
+                                                                                 79 1/2" Case
+                                                                                                                                                         5"                               2                                  2  2                 2
+                                                                                                                                                             36 7/8"
+                                                                                                                                                                                                              Arrangement 3        Arrangement 4
+                                                                                                                                                                 Typ.
+                                                                                                                                                                     45 1/8" Typ.
+
+LEFT VIEW                                                                                      PAIN              FRONTPAINVIEW                     PAIN                                                               Performance Derating:
+                                                                                                                                                                                             Airflow Arrangements 3 & 4 result in lower energy transfer.
+
+                                                                                                                                                                                               Reduce sensible effectiveness by 2 percentage points.
+                                                                                                                                                                                          PAIN Reduce total effectiveness by 1 percentage point.
+
+MDroadweAAinvlI:aRgilPaFbATLleyO1aps2WesXh:oCwUOnn: NitFDIGimUReAnTsIiOoNn                    1           RA/OA  RA/OA  2                   RA/OA  3                               RA/OA  4                                     UNIT MOUNTING & APPLICATION
+                                                                                                     EA/FA       RA/OA                                                             RA/OA
+                                                                            RA/OA                                                    EA/FA                      EA/FA                                 EA/FA                     Must be mounted as shown. RA/EA airstream can
+                                                                                  EA/FA                                              EA/FA                                                             EA/FA                    be switched with OA/FA airstream. Knockdown can
+                                                                                                                                            EA/FA                      RA/OA                                                    be field assembled for multiple duct configurations.
+Version: AUG18                                                                                                                                                                                                                  Multiple cabinets can be aligned for unlimited airflow.
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
+
+                                                                      FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 17
+CERTIFICATIONS & PERFORMANCE
+
+AHRI 1060
+
+CERTIFIED PERFORMANCE
+
+Energy recovery component certified in accordance with AHRI Standard 1060-2013.
+Actual performance in packaged equipment may vary.
+
+                                       AHRI-1060 Certified Performance - Model Number L125-G5
+
+              Type                          Tilt Angle                          Nominal Airflow                                           Pressure Drop
+              Plate                            N/A
+                                                                                100% - 750 SCFM                                          0.65 in. H20
+                   Leakage Ratings                                              75% - 563 SCFM
+
+                                                                       Thermal Effectiveness Ratings at 0" Pressure Differential
+
+ Pressure     EATR               OACF  Purge Angle or  Nominal Airflow  Sensible Latent        Total   Net      Net                        Net           Net
+Differential                               Setting                                                   Airflow  Sensible                    Latent         Total
+-1 in. H20
+              1.0%               1.00  N/A             750 Heating     70%      52%           64%    750     70%                         52%            64%
+ 0 in. H20
+                                                       CFM Cooling     70%      42%           53%    CFM     70%                         42%            53%
+ 1 in. H20
+              0.0%               1.02  N/A
+
+                                                       563 Heating     74%      59%           69%    563     74%                         59%            69%
+
+              0.0%               1.05  N/A             CFM Cooling     74%      49%           58%    CFM     74%                         49%            58%
+
+NOTE: SCFM = Standard Cubic Feet per Minute OACF = Outdoor Air Correction Factor EATR = Exhaust Air Transfer Ratio N/A = Not Applicable
+
+18 RENEWAIRE.COM 1.800.627.4499
+                                                                                                                                         ORDERING & SUPPORT
+
+                                        CA & PA MODEL
+                                 CONFIGURATION GUIDE
+
+                                       Note: Not all options are available on every model.
+
+MODEL NUMBER                                 J                           ------------ N
+
+DIGIT NUMBER  123                4        567       8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
+
+ Digits 1 - 2: Model                                                      Digit 11:                       Wall Type (see Restriction 4)
+"CA-2X" = Cabinet Applied 2 Cores                                        "S" = Single
+"CA-3X" = Cabinet Applied 3 Cores                                        "D" = Double
+"CA-4X" = Cabinet Applied 4 Cores
+"PA-6X" = Panelized Applied 6 Cores                                      Digit 24:                        Other Options (see Restriction 5, 6 & 7)
+"PA-8X" = Panelized Applied 8 Cores
+"PA-9X" = Panelized Applied 9 Cores                                      "-" = None
+"PA12X" = Panelized Applied 12 Cores                                     "K" = Knockdown
+                                                                         "A" = Assembled
+ Digits 7 - 8: Location (see Restriction 1)                              "W" = White Paint
+"IN" = Indoor                                                            "C" = Custom Paint
+"RT" = Rooftop                                                           "X" = Custom Unit
+
+                                                                         Digit 25:                        Safety Listing
+
+Digit 9:      Forklift Base                                              "N" = Non-Listed
+
+"-" = None (CA Models)
+"9" = Forklift Base (PA Models)
+
+Digit 10:     Orientation (see Restrictions 2 & 3)
+
+"1" = Opposite-side Entry, Cross-flow
+"2" = Same-side Entry, Cross-flow
+"3" = Opposite-side Entry, Parallel-flow
+"4" = Same-side Entry, Parallel-flow
+"-" = Flexible Airflow
+
+*NOTES:                      Digits 12-23 are not used in these models.
+Digit 6 "J" = G5 Core Type
+
+Restrictions:
+ 1: Location Code "RT" only available with CA models.
+ 2: Orientation Code "-" only available on CA models & PA models with Flexible Packaging Code "K".
+ 3: Orientation Codes "1", "2", "3",& "4" only availble with PA models with Flexible Packaging Code "A".
+ 4: Wall Code "D" only available with CA models.
+ 5: Other Option Codes "W" & "C" only available with CA models.
+ 6: Other Option Code "W" only available with CA models with Location Code "RT".
+ 7: Other Option Codes "A" & "K" only available with PA models.
+
+                                                           CA and PA MODELS
+                                             COMMERCIAL PRODUCT CODE CHART
+
+                                          For Technical Support E-mail: RenewaireSupport@renewaire.com
+                                            To Place an Order E-mail: RenewaireOrders@renewaire.com
+
+                                                                                                         FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 19
+ORDERING & SUPPORT
+
+                    INDOOR AIR QUALITY MATTERS
+
+                    u Deficient IAQ is an EPA top-five health risk
+
+                    u People spend 90% of their time indoors
+
+                    u Indoor air can be 2-5 times and up to 100 times
+                       more polluted than outdoor air
+
+BENEFITS OF INCREASED VENTILATION
+
+                                 BETTER          IMPROVED   INCREASED
+                                 HEALTH          COGNITIVE  PRODUCTIVITY
+                                                 FUNCTION
+
+TECHNICAL/APPLICATIONS SUPPORT
+The goal of our technical-support team is to provide the BEST CUSTOMER SERVICE
+in the HVAC industry. You can count on our knowledgeable and seasoned staff for all your technical,
+application and service needs, and we’ll respond quickly and effectively to answer any of your questions.
+
+                    CONTACT RENEWAIRE
+
+                                 PHONE:          FOR TECHNICAL SUPPORT:
+                                 1.800.627.4499  RenewaireSupport@renewaire.com
+
+                                 FAX:            TO PLACE AN ORDER:
+                                 608.221.2824    RenewaireOrders@renewaire.com
+
+20 RENEWAIRE.COM 1.800.627.4499
+RELEVANT                                                           RENEWAIRE
+
+EVERYWHERE                                                  TEMPERS THE AIR
+
+EVERY GEOGRAPHIC REGION                                    Our ERVs moderate the extremes
+Our ERVs function perfectly across the world in every      of outdoor supply-air temperature
+geographic region.                                         and humidity year-round, providing
+                                                           a sustainable solution for fresh air
+EVERY CLIMATE                                              that feels like a perfect spring day.
+Our ERVs operate in every climate—from Alaska to
+Florida, and everywhere in between.
+
+EVERY PROJECT
+From massive skyscrapers to cozy residential homes,
+our ERVs can be used in every size project and in every
+code jurisdiction.
+
+APPLIED EVERYWHERE
+
+When indoor occupants breathe in unclean air, this harms their health and causes cognitive impairment. Our ERVs can
+provide cleaner and healthier indoor air for every type of building in the world, thus improving occupants’ wellbeing,
+while also reducing energy costs.
+
+RESIDENTIAL                                                DAYCARE
+The increased airtightness of newer and remodeled          Crowded daycare facilities breed deficient IAQ, thus
+homes is causing deficient IAQ, resulting in more health   causing health problems for everyone—especially
+problems for indoor occupants.                             children who are more vulnerable.
+
+COMMERCIAL                                                 EDUCATION (LOWER AND HIGHER)
+As commercial buildings become more airtight,              With students and teachers packed into tight classrooms,
+deficient IAQ is increasing and causing sickness,          instances of deficient IAQ go up, resulting in academic
+absenteeism and decreased productivity.                    performance and test scores going down.
+
+H E A LT H C A R E                                         GOVERNMENT
+The high occupant density of hospitals, nursing homes      Aging and crowded government buildings result in
+and other healthcare facilities results in deficient IAQ   deficient IAQ, which can impair worker performance
+and ensuing health problems for patients and staff alike.  and productivity.
+
+RESTAURANTS/COFFEE SHOPS                                   EVERY TYPE OF BUILDING
+The large volume of indoor occupants in restaurants        Every type of building can benefit from the enhanced
+and coffee shops causes deficient IAQ and subsequent       IAQ generated by RenewAire ERVs, including
+health problems.                                           veterinary clinics, nail salons and manufacturing
+                                                           facilities, among others.
+RETAIL
+The high level of foot traffic in retail stores leads
+to deficient IAQ and the potential sickness of shoppers,
+which can negatively impact sales.
+        RENEWAIRE EVERYWHERE                                       LIT113_00 (01/19)
+
+       RenewAire ERVs can be applied everywhere across all
+         commercial, educational, institutional, light industrial
+
+      and residential buildings. Our technology excels in every
+     geographic region, every climate, and every size project.
+
+Member of the S&P Group
+Family of Brands
+ERV
+                        EV450 & HE SERIES
+
+                                      COMMERCIAL ERV CATALOG
+
+JANUARY 2019
+
+RENEWAIRE.COM | 800.627.4499
+BECAUSE INDOOR
+
+AIR QUALITY MATTERS
+
+As buildings become more airtight due to better                                                 application of ERV technologies. Deficient IAQ is a
+construction methodologies, the need for increased                                              serious problem, especially considering:
+and balanced ventilation is critical. Without it, internally                                    u	On average, Americans spend 90% of their time indoors
+generated contaminants accumulate and cause deficient                                           u	The EPA found that indoor air may be 2-5 times—and
+indoor air quality (IAQ), which leads to significant
+health and cognitive problems for occupants. Industry                                              occasionally greater than 100 times—more polluted
+standards are changing to combat deficient IAQ, and                                                than outdoor air
+codes that adopt these new standards are driving the                                            u	The EPA ranks indoor air pollutants as a top-five
+                                                                                                   environmental health risk to occupants
+
+HEALTH    PRODUCTIVITY                                                                          LEARNING
+MAT TERS  MAT TERS                                                                              MAT TERS
+
+ADVERSE EFFECTS                                                                                 ABOUT RENEWAIRE
+
+O F DEFICIENT IAQ                                                                               For over 30 years, RenewAire has been
+                                                                                                a pioneer in enhancing IAQ in commercial and
+Deficient IAQ has numerous adverse effects on the                                               residential buildings of every size. This is achieved
+health and cognitive function of building occupants.                                            while maximizing sustainability through our fifth-
+                                                                                                generation, enthalpic-core, static-plate Energy
+                  Health problems: Acute allergies,                                            Recovery Ventilators (ERVs) that optimize energy
+                  headaches, coughs, asthma, skin                                               efficiency, lower capital costs via HVAC load
+                  irritations and breathing difficulties,                                       reduction and decrease operational expenses
+                  as well as chronic illnesses such as                                          by minimizing equipment needs, resulting
+                  cancer, liver disease, kidney damage                                          in significant energy savings. Our ERVs are
+                  and nervous-system failure.                                                   competitively priced, simple to install, easy to use
+                                                                                                and maintain, have a quick payback and enjoy the
+                  Cognitive impairment: Studies by the                                         industry’s best warranty with the lowest claims
+                  Harvard School of Public Health and the                                       due to long-term reliability. In 2010, RenewAire
+                  Lawrence Berkeley National Laboratory                                         joined the Soler & Palau (S&P) Ventilation Group,
+                  found that carbon dioxide (CO )—an                                            providing direct access to the latest in energy-
+                                                                                                efficient air-moving technologies. For more
+                                                                                             2  information, visit: renewaire.com.
+
+                  indoor air contaminant—negatively impacted
+                  thinking and decision-making at levels
+                  commonly found inside homes and buildings.
+                                                                                                                                                                                             TABLE OF CONTENTS
+
+                                TABLE OF
+
+CONTENTS
+
+EV450 - Light Commercial Unitary ERV                                   HE2X - Commercial Unitary ERV
+
+MODEL                             TYPE     CFM RANGE           PAGE    MODEL                             TYPE     CFM RANGE        PAGE
+EV450IN - STANDARD                Indoor   200-540 CFM            4-5  HE2XINH - STANDARD                Indoor   500-2,200 CFM    66-67
+                                                                  6-7  HE2XINH - STANDARD BYPASS OPTION  Indoor   500-2,200 CFM    68-69
+EV450IN - EC MOTOR OPTION         Indoor   200-530 CFM                 HE2XINV - STANDARD                Indoor   500-2,200 CFM    70-71
+EV450RT - STANDARD                Rooftop  240-500 CFM    8-9, 12-13   HE2XINV - STANDARD BYPASS OPTION  Indoor   500-2,200 CFM    72-73
+EV450RT - EC MOTOR OPTION         Rooftop  200-510 CFM         10-13   HE2XRT - STANDARD                 Rooftop  500-2,000 CFM    74-76
+                                                                       HE2XRTC - STANDARD                Rooftop  500-1,700 CFM    78-79
+
+HE1X - Light Commercial Unitary ERV
+
+MODEL                             TYPE     CFM RANGE      PAGE         HE3X - Commercial Unitary ERV
+HE1XINH - STANDARD                Indoor   250-925 CFM    14-15
+HE1XINH - EC MOTOR OPTION         Indoor   250-1,100 CFM  16-17        MODEL                             TYPE     CFM RANGE        PAGE
+HE1XINH - STANDARD BYPASS OPTION  Indoor   250-925 CFM    18-19        HE3XINH - STANDARD                Indoor   750-3,300 CFM    80-81
+HE1XINH - EC MOTOR BYPASS OPTION  Indoor   250-1,100 CFM  20-21        HE3XINH - STANDARD BYPASS OPTION  Indoor   750-3,300 CFM    82-83
+HE1XINV - STANDARD                Indoor   250-925 CFM    22-23        HE3XINV - STANDARD                Indoor   750-3,300 CFM    84-85
+HE1XINV - EC MOTOR OPTION         Indoor   250-1,100 CFM  24-25        HE3XINV - STANDARD BYPASS OPTION  Indoor   750-3,300 CFM    86-87
+HE1XINV - STANDARD BYPASS OPTION  Indoor   250-925 CFM    26-27        HE3XRT - STANDARD                 Rooftop  750-3,300 CFM    88-90
+HE1XINV - EC MOTOR BYPASS OPTION  Indoor   250-1,100 CFM  28-29        HE3XRTC - STANDARD                Rooftop  1,100-2,400 CFM  92-93
+HE1XRT - STANDARD                 Rooftop  250-870 CFM    30-32
+HE1XRT - EC MOTOR OPTION          Rooftop  250-1,100 CFM  34-36        HE4X - Commercial Unitary ERV
+HE1XRTC - STANDARD                Rooftop  500-900 CFM    38-39
+HE1XRTC - EC MOTOR OPTION         Rooftop  500-1,100 CFM  40-41
+
+HE1.5X - Commercial Unitary ERV                                        MODEL                             TYPE     CFM RANGE           PAGE
+                                                                       HE4XINH - STANDARD                Indoor   1,000-4,400 CFM    94-95
+MODEL                             TYPE     CFM RANGE      PAGE         HE4XINH - STANDARD BYPASS OPTION  Indoor   1,000-4,400 CFM    96-97
+                                           375-1,575 CFM  42-43        HE4XINV - STANDARD                Indoor   1,000-4,400 CFM    98-99
+HE1.5XINH - STANDARD              Indoor   375-1,575 CFM  44-45        HE4XINV - STANDARD BYPASS OPTION  Indoor   1,000-4,400 CFM  100-101
+                                           375-1,575 CFM  46-47        HE4XRT - STANDARD                 Rooftop  1,000-4,400 CFM  102-104
+HE1.5XINH - EC MOTOR OPTION       Indoor   375-1,575 CFM  48-49        HE4XRTC - STANDARD                Rooftop  2,500-3,900 CFM  106-107
+                                           375-1,575 CFM  50-51
+HE1.5XINH - STANDARD BYPASS OPTION Indoor  375-1,575 CFM  52-53
+                                           375-1,575 CFM  54-55
+HE1.5XINH - EC MOTOR BYPASS OPTION Indoor  375-1,575 CFM  56-57
+                                           375-1,575 CFM  58-60
+HE1.5XINV - STANDARD              Indoor   375-1,525 CFM  62-64
+
+HE1.5XINV - EC MOTOR OPTION       Indoor                               HE6X - Commercial Unitary ERV
+
+HE1.5XINV - STANDARD BYPASS OPTION Indoor                              MODEL                             TYPE     CFM RANGE           PAGE
+                                                                       HE6XIN - STANDARD                 Indoor   1,500-6,500 CFM  108-109
+HE1.5XINV - EC MOTOR BYPASS OPTION Indoor                              HE6XIN - STANDARD BYPASS OPTION   Indoor   1,500-6,500 CFM  110-111
+                                                                       HE6XRT - STANDARD                 Rooftop  1,500-6,500 CFM  112-113
+HE1.5XRT - STANDARD               Rooftop
+
+HE1.5XRT - EC MOTOR OPTION        Rooftop
+
+ABOUT RENEWAIRE                                                2-3     HE8X - Commercial Unitary ERV
+SPECIFICATIONS & DIMENSIONS                                 4-119
+OPTIONS & ACCESSORIES                                     121-139      MODEL                             TYPE     CFM RANGE           PAGE
+CERTIFICATIONS & PERFORMANCE                                           HE8XIN - STANDARD                 Indoor   2,000-7,950 CFM  114-115
+ORDERING & SUPPORT                                             140     HE8XIN - STANDARD BYPASS OPTION   Indoor   2,000-7,950 CFM  116-117
+                                                          141-144      HE8XRT - STANDARD                 Rooftop  2,000-7,950 CFM  118-119
+
+                                                                       FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 1
+   ABOUT RENEWAIRE
+
+   R E N E WA I R E E R Vs
+
+   ACHIEVE SUSTAINABLE IAQ
+
+   RenewAire is a pioneer in enhancing IAQ while maximizing sustainability through enthalpic-core, static-plate Energy
+   Recovery Ventilators (ERVs) that optimize energy efficiency, lower costs by reducing HVAC loads and therefore
+   reduce environmental footprints. Our ERV technology preconditions incoming air with the otherwise-wasted energy
+   (heat and humidity) of the exhaust air going out—all while the airstreams are kept physically separate as certified by
+   the Air Conditioning, Heating and Refrigeration Institute (AHRI) for zero exhaust air transfer at normal balanced operating
+   conditions. As the pioneer of static-plate core technology in North America, RenewAire is the largest ERV producer in the USA.
+
+   OPTIMIZING                                               OA  COOLING SEASON    RA        OA  HEATING SEASON         RA
+   ENERGY EFFICIENCY
+                                                                       EFFICIENT                       EFFICIENT
+   Energy efficiency is optimized by preconditioning            HEAT & HUMIDITY                 HEAT & HUMIDITY
+   the outside air coming in with the otherwise-wasted
+   heat and humidity of the exhaust air going out. This                TRANSFER                        TRANSFER
+   exchange of energy moderates temperatures and moisture,
+   decreases HVAC equipment needs, drives operational       EA                    FA        EA                         FA
+   efficiencies and conserves energy.
+
+   REDUCING HVAC LOADS                                                                               INSIDE                  OUTSIDE
+                                                                                                Fresh Air Enters       Stale Room Air Exits
+   RenewAire technology reduces HVAC loads during both winter and summer. In turn,
+   HVAC equipment size and needs can be decreased and furnaces and air conditioners           Fixed Partition
+   can be smaller. This process ensures efficient operations and keeps both energy use and  and Spacer Plates
+   costs low, while at the same time maintaining high-level IAQ.
+                                                                                               (proprietary resin
+                                                                                            and composite media)       Outside Air
+
+                                                                                                       Stale Room Air
+
+   MINIMIZING ENVIRONMENTAL IMPACT
+
+   The combination of less energy used and HVAC loads being reduced conserves resources. Further, our Madison, WI plant
+   is 100% powered by renewable wind energy, and is one of the few buildings worldwide to be LEED and Green Globes
+   certified, as well as having achieved ENERGY STAR Building status. This commitment to sustainable manufacturing
+   minimizes our overall production and distribution environmental footprint.
+
+2
+                                                                                                                                                                                                    ABOUT RENEWAIRE
+
+WHY RENEWAIRE
+
+IS PREFERRED
+
+                  BEST VALUE
+
+                       u Priced competitively against other ERV models
+                       u Due to competitive pricing and decreased costs, payback is short and ROI is maximized
+                       u Contractors can pass these significant savings along to their customers
+
+                  RELIABLE OPERATION
+
+                       u Built-to-last ERVs have lifespans of 25+ years and operate consistently year-round in every extreme,
+                          including frost-free performance in all but the most severe winter climates
+
+                       u High-efficiency core operates dry in all conditions, meaning no condensate pans
+                       u An industry-leading ten-year warranty for the static-plate core, two-year warranty for commercial
+
+                          products and a five-year warranty for residential products
+                       u Superior product quality results in paramount reliability and longevity
+
+                  HIGHEST-QUALITY INDOOR AIR
+
+                       u Stale indoor air is replaced with fresh, conditioned and filtered air from
+                          the outside, resulting in Enhanced IAQ by removing harmful contaminants
+
+                       u Airstreams do not mix and pollutants are not transferred across partition plates
+                       u No biocide used; material does not promote biological growth
+                       u Moderated temperatures and humidity maintain a comfortable indoor environment
+
+                  OPTIMIZED ENERGY EFFICIENCY
+
+                       u Efficient heat and humidity transfer recaptures up to 70-80% of the energy exhausted in the airstream
+                       u Energy that’s otherwise wasted by conventional ventilation systems (such as bath fans) is reused,
+
+                          thus dramatically reducing monthly operation costs
+                       u Energy-efficient operation decreases HVAC loads, which cuts down on energy use and costs
+                       u The hotter or colder the climate, the more energy is recovered
+
+                  HIGHLY CERTIFIED
+
+                       u See individual catalog submittal for certification details:
+                                 u UL u cUL u ETL u HVI u AHRI
+
+                                                                                                                                                                                                                                     3
+SPECIFICATIONS & DIMENSIONS                                      Energy Recovery Ventilator
+                                                                 Standard
+EV 450IN
+                                                                 SPECIFICATIONS
+INDOOR UNIT
+                                                                 Ventilation Type:                                                      Accessories:
+Download specification at:                                       Static plate, heat and humidity transfer                               Filters - MERV 13, 2" (shipped loose)
+renewaire.com/specifications                                                                                                            Backdraft damper 10"
+                                                                 Typical Airflow Range: 200-540 CFM                                      Wall cap 10" - galvanized, paintable galvanneal
+                                                                                                                                        Vibration isolation kit
+                                                                 AHRI 1060 Certified Core: One L85-G5                                    Hanging bracket kit
+                                                                                                                                        Transition kit 10" - round, qty. 2
+                                                                 Standard Features:                                                     Flange kit - rectangular 12" x 8", 2 flanges
+                                                                 Non-fused disconnect                                                   Solid state speed control kit - 115V, qty. 1,
+                                                                 24 VAC transformer/relay package
+                                                                 Cross-core differential pressure ports                                    208-230V, qty. 1
+                                                                                                                                        Digital time clock - wall mount (TC7D-W),
+                                                                 Filters:
+                                                                 Total qty. 2, MERV 8: 14" x 20" x 2"                                      in exterior enclosure (TC7D-E)
+                                                                                                                                        Carbon dioxide sensor/control -
+                                                                 Unit Dimensions & Weight:
+                                                                 54 1/2" L x 16 3/8" W x 36 3/4" H                                         wall mount (CO2-W), duct mount (CO2-D)
+                                                                 137-199 lbs., varies by option(s)                                      IAQ sensor - wall mount (IAQ-W),
+
+                                                                 Max. Shipping Dimensions & Weight (on pallet):                            duct mount (IAQ-D)
+                                                                 62" L x 42" W x 22" H                                                  Motion occupancy sensor/control -
+                                                                 250 lbs.
+                                                                                                                                           ceiling mount (MC-C), wall mount (MC-W)
+                                                                 Motor(s), choice of:                                                   Smoke detector - duct mount (SD-D)
+                                                                 Qty. 1, 0.6 HP (standard single phase)                                 Louver with 10" round duct connection -
+                                                                 Qty. 1, 0.5 HP (standard three phase)
+                                                                                                                                           12" (W) x 12" (H)
+                                                                 Options:                                                               Electric duct heater - RH series (1-11.5 kW);
+                                                                 Qty. 1, Variable Speed/ECM - Direct Drive Motors
+                                                                                                                                           EK series (1–175 kW);
+                                                                    (see EV450IN EC Motor submittal) -                                     designed for indoor ductwork installation only
+                                                                    0.5 HP, 120V/1Ph/60HZ,
+                                                                    0.5 HP, 208-230V/1Ph/60HZ
+                                                                 Fused disconnect
+                                                                 Integrated programmable controls -
+                                                                    enhanced, premium
+                                                                 Qty. 2, Factory mounted filter alarms -
+                                                                    both airstreams
+                                                                 Double wall construction
+                                                                 Exterior paint - white, custom colors
+
+                                                                 Note: Indirect Gas-Fired Duct Furnace is not available on the EV450IN.
+
+ELECTRICAL DATA                                                  UNIT PERFORMANCE
+
+               Thermal  PeFrLfAormaAnMCmciinrep..sRatOinPvrgeDosMretceGvaucix5crt.rieoe2nn0t15.2.xlsx  Airflow CFM       EV450 (IOM)                     Watts
+                 Phase                                                                                                      ESP in H20
+HP  Volts  HZ                                                                                               225                                     1P                                              3P
+                                                                                                            375                 1.25         335                                                         181
+0.6 120 60 Single 7.2 9.0                                    15                                             420                 0.89         464                                                         333
+                                                                                                            480                 0.75         518                                                         394
+0.6 208-230 60 Single 3.9-3.6 4.9                            15                                             500                 0.50         584                                                         472
+                                                                                                            540                 0.43         600                                                         491
+0.6 277 60 Single 3.5 4.4                                    15                                                                 0.25         640                                                         540
+                                                                                                                                                                                                         610
+0.5 208-230 60 Three 1.7-1.5 2.1                             15
+
+0.5 460 60 Three 0.8 1.0                                     15
+
+                                                                                                            575              0.00            690
+
+                                                                 Note: Watts is for the entire unit.
+                                                                 Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+                                                                 CORE PERFORMANCE
+
+                                                                                                                   Airflow (CFM)
+
+                                                                 Effectiveness (%)                          200    300  400        500  600
+
+                                                                                                       90%
+
+                                                                                                       70%
+
+                                                                                                       50%
+
+                                                                                                       30%
+                                                                                                               At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+     Specifications may be subject to change without notice.
+4 RENEWAIRE.COM 1.800.627.4499
+                                                                     EV450IN Energy Recovery Ventilator Standaarrdd or EC Motor Option
+
+                                                                                                                                                            1 1/2" Typ.                    47 1/8" Overall                                                  ABBREVIATIONS
+                                                                                                                                                                                           (with Flanges)                                                   EA: Exhaust Air to outside
+                                                                                                                                                                                                                                                            OA: Outside Air intake
+                                                                                                                                                                                            44 1/8" Case                                                    RA: Room Air to be exhausted
+                                                                                                                                                                                                                                                            FA: Fresh Air to inside
+                                                                                                                                                                                           Door   Door                                                      INSTALLATION ORIENTATION
+                                                                                                                                                                                           Swing  Swing                                                     Unit may be installed in any orientation.
+                                                                                                                                                                                                                                                            NOTE
+                                                                                                                                                                                                                                                            1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                            DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                            NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                            2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                            TO CHANGE WITHOUT NOTICE.
+
+                                                                                                                                                            14 1/4" Minimum                44 1/2" Minimum
+                                                                                                                                                               Service Area                  Service Area
+
+                                                                                                                                                                   (Doors can be
+                                                                                                                                                                      Removed from
+
+                                                                                                                                                                          Hinges)
+                                                                                                                                                                                  24 3/4"
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 5  12" X 8" Typ.           11 1/4"                                         5 1/4" Typ.                                       TOP VIEW                                                     16 3/8"  10 1/8"
+                                                                     Duct Flange                                                                                                                                                                            Overall
+                                                                                                                                                   10"      5 1/8" Typ.                          54 1/2" Overall
+                                                                        (Optional                                                               Round Typ.               EA                (with Round Transitions)                                         15 7/8"
+                                                                            45EVDF                                                              (Optional                                                                                                    Case
+                                                                                                                                                45EVT10                                                                                   OA
+                                                                       Kit Shown)                                                               Transition                                                                           RA
+                                                                                                                                                Kit Shown)                                                        Pressure
+                                                                     4 1/4" Typ.    25 1/4"                                                                                                                       Ports (4) Typ.              33 7/8" Case                    26 1/4"
+                                                                         20 1/4"                                                                                                                                                                                                         36 3/8" Overall
+                                                                                                                                                                              FA             FRONT VIEW
+                                                                             Typ.
+                                                                                                                                                            CL 2 1/4" Control In
+                                                                     7/8"                     7/8" Power In                                                 CL 14 1/4" Power In                                                                                      6 3/8"                               2 1/8"
+                                                                     Typ.                          Disconnect                                               (2) 7/8" Holes                                                                                                                                 Typ.
+                                                                                                          Switch                                            for Wiring in
+                                                                        CL 4 1/8"                     7/8" Control In                                       Bottom of E-Box
+                                                                        Power In
+                                                                                    LEFT VIEW
+                                                                         CL 2 5/8"
+                                                                       Control In
+
+                                                                     MoAAvdIaRielaFblL:leOEasVWs4hoC5w0On IiNNn dFimIGenUsiRonAdTraIwOinNg.                                                                                                                          RIGHT VIEW
+                                                                     Drawing Type: Unit Dimension
+                                                                     Version: MAY17                                                                                                                                                                                     UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                                                                                                        Can be mounted in any orientation. RA/EA airstream
+                                                                                                                                                                                                                                                                        can be switched with OA/FA airstream.
+
+                                                                                                                                                                                                                                                                        EV-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+EV 450IN                                                                  Energy Recovery Ventilator
+                                                                          EC Motor Option
+
+INDOOR UNIT                                                               SPECIFICATIONS
+
+Download specification at:                                                Ventilation Type:                                                                                Accessories:
+renewaire.com/specifications                                              Static plate, heat and humidity transfer                                                         Filters - MERV 13, 2" (shipped loose)
+                                                                                                                                                                           Backdraft damper 10"
+                                                                          Typical Airflow Range: 200-530 CFM                                                                Wall cap 10" - galvanized, paintable galvanneal
+                                                                                                                                                                           Vibration isolation kit
+                                                                          AHRI 1060 Certified Core: One L85-G5                                                              Hanging bracket kit
+                                                                                                                                                                           Transition kit - 10" round, qty. 2
+                                                                          Standard Features:                                                                               Flange kit - rectangular 12" x 8", 2 flanges
+                                                                          Non-fused disconnect                                                                             Potentiometer speed control - remote installed
+                                                                          24 VAC transformer/relay package                                                                 Digital time clock - wall mount (TC7D-W),
+                                                                          Cross-core differential pressure ports
+                                                                                                                                                                              in exterior enclosure (TC7D-E)
+                                                                          Filters:                                                                                         Carbon dioxide sensor/control -
+                                                                          Total qty. 2, MERV 8: 14" x 20" x 2"
+                                                                                                                                                                              wall mount (CO2-W), duct mount (CO2-D)
+                                                                          Unit Dimensions & Weight:                                                                        IAQ sensor - wall mount (IAQ-W),
+                                                                          54 1/2" L x 16 3/8" W x 36 3/4" H
+                                                                          140-202 lbs., varies by option(s)                                                                   duct mount (IAQ-D)
+                                                                                                                                                                           Motion occupancy sensor/control -
+                                                                          Max. Shipping Dimensions & Weight (on pallet):
+                                                                          62" L x 42" W x 22" H                                                                               ceiling mount (MC-C), wall mount (MC-W)
+                                                                          250 lbs.                                                                                         Smoke Detector - duct mount (SD-D)
+                                                                                                                                                                           Louver with 10" round duct connection -
+                                                                          Motor(s):
+                                                                          Qty. 1, 0.5 HP, Direct drive EC blower/                                                             12" (W) x 12" (H)
+                                                                                                                                                                           Electric duct heater - RH series (1-11.5 kW);
+                                                                             motor package
+                                                                                                                                                                              EK series (1–175 kW);
+                                                                          Options:                                                                                            designed for indoor ductwork installation only
+                                                                          Fused disconnect
+                                                                          Integrated programmable controls -
+
+                                                                             enhanced, premium
+                                                                          Qty. 2, Factory mounted filter alarms -
+
+                                                                             both airstreams
+                                                                          Double wall construction
+                                                                          Exterior paint - white, custom colors
+
+EC MOTOR OPTION OPERATING RANGE                                           Note: Indirect Gas-Fired Duct Furnace is not available on the EV450IN.
+                                                                                                                       EV450-IN ECM
+
+                                                                                                                  1.25                                              487
+                                                                                                                                                             449
+                    EV450IN EC MOTOR
+         Sample Points Depicted in Larger Dots
+
+    Airflow   External Static    Unit Power                                                                     1.00                                                             515
+    (CFM)       Pressure       Consumption                                                                                                                           447
+
+             (Inches Water        (Watts)                                                                                                          328
+                Column)
+
+    229               0.07                                   75           External Static Pressure (in. w.g.)                                                                       521
+                                                                                                                                                                         436
+    321     Thermal0P.1e6rformance Ratin1g7s1G5 2015.2.xlsx 0.75                                                                              EV45031(I5OM)
+
+    395               0.25                                   284                                                                                                                               520
+
+    458               0.34                                   410                                                                         198                 307           427
+
+    491               0.40                                   506                                               0.50                      188
+
+                                                                                                                                                                  299                               506
+
+    209               0.20                                   80                                                                               183                                         410
+
+    289               0.43                                   188                                                                              177                 284
+                                                                                                                                                 171                  269
+    350               0.67                                   315                                               0.25 80                              160                                        403       500 (Watts)
+                                                                                                                            80
+    396               0.90                                   447                                                              76
+
+                                                                                                                                75
+
+    416               1.00                                   515                                                             74
+
+Note: Watts is for the entire unit.                                                                            0.00
+Note: Airflow performance includes effect of clean, standard filter
+supplied with unit.                                                                                                     200         250  300            350       400                450            500  550          600
+
+                                                                                                               = Actual tested sample points Airflow (cfm)
+
+                                                                          CORE PERFORMANCE
+
+ELECTRICAL DATA                                                                                                                          Airflow (CFM)
+
+                              Min.                               Max.     Effectiveness (%)                         200             300            400            500                600
+                               Cir.                          Overcurrent
+HP  Volts   HZ Phase  FLA     Amps                           Protection                                        90%
+
+                                                                Device
+
+0.5 120 60 Single 8.1 10.1                                        15                                           70%
+
+0.5 208-230 60 Single 4.8 6.0                                     15                                           50%
+
+                                                                                                               30%
+                                                                                                                       At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+     Specifications may be subject to change without notice.
+6 RENEWAIRE.COM 1.800.627.4499
+                                                                     EV450IN Energy Recovery Ventilator SEtCanMdoatrodr oOrpEtiConMotor Option
+
+                                                                                                                                                            1 1/2" Typ.                    47 1/8" Overall                                                  ABBREVIATIONS
+                                                                                                                                                                                           (with Flanges)                                                   EA: Exhaust Air to outside
+                                                                                                                                                                                                                                                            OA: Outside Air intake
+                                                                                                                                                                                            44 1/8" Case                                                    RA: Room Air to be exhausted
+                                                                                                                                                                                                                                                            FA: Fresh Air to inside
+                                                                                                                                                                                           Door   Door                                                      INSTALLATION ORIENTATION
+                                                                                                                                                                                           Swing  Swing                                                     Unit may be installed in any orientation.
+                                                                                                                                                                                                                                                            NOTE
+                                                                                                                                                                                                                                                            1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                            DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                            NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                            2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                            TO CHANGE WITHOUT NOTICE.
+
+                                                                                                                                                            14 1/4" Minimum                44 1/2" Minimum
+                                                                                                                                                               Service Area                  Service Area
+
+                                                                                                                                                                   (Doors can be
+                                                                                                                                                                      Removed from
+
+                                                                                                                                                                          Hinges)
+                                                                                                                                                                                  24 3/4"
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 7  12" X 8" Typ.           11 1/4"                                         5 1/4" Typ.                                       TOP VIEW                                                     16 3/8"  10 1/8"
+                                                                     Duct Flange                                                                                                                                                                            Overall
+                                                                                                                                                   10"      5 1/8" Typ.                          54 1/2" Overall
+                                                                        (Optional                                                               Round Typ.               EA                (with Round Transitions)                                         15 7/8"
+                                                                            45EVDF                                                              (Optional                                                                                                    Case
+                                                                                                                                                45EVT10                                                                                   OA
+                                                                       Kit Shown)                                                               Transition                                                                           RA
+                                                                                                                                                Kit Shown)                                                        Pressure
+                                                                     4 1/4" Typ.    25 1/4"                                                                                                                       Ports (4) Typ.              33 7/8" Case                    26 1/4"
+                                                                         20 1/4"                                                                                                                                                                                                         36 3/8" Overall
+                                                                                                                                                                              FA             FRONT VIEW
+                                                                             Typ.
+                                                                                                                                                            CL 2 1/4" Control In
+                                                                     7/8"                     7/8" Power In                                                 CL 14 1/4" Power In                                                                                      6 3/8"                               2 1/8"
+                                                                     Typ.                          Disconnect                                               (2) 7/8" Holes                                                                                                                                 Typ.
+                                                                                                          Switch                                            for Wiring in
+                                                                        CL 4 1/8"                     7/8" Control In                                       Bottom of E-Box
+                                                                        Power In
+                                                                                    LEFT VIEW
+                                                                         CL 2 5/8"
+                                                                       Control In
+
+                                                                     MoAAvdIaRielaFblL:leOEasVWs4hoC5w0On IiNNn dFimIGenUsiRonAdTraIwOinNg.                                                                                                                          RIGHT VIEW
+                                                                     Drawing Type: Unit Dimension
+                                                                     Version: MAY17                                                                                                                                                                                     UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                                                                                                        Can be mounted in any orientation. RA/EA airstream
+                                                                                                                                                                                                                                                                        can be switched with OA/FA airstream.
+
+                                                                                                                                                                                                                                                                        EV-SERIES
+SPECIFICATIONS & DIMENSIONS                                               Energy Recovery Ventilator
+                                                                          Standard
+EV 450RT
+                                                                          SPECIFICATIONS
+ROOFTOP UNIT
+                                                                          Ventilation Type:                                    Accessories:
+Download specification at:                                                Static plate, heat and humidity transfer             Filters - MERV 13, 2" (shipped loose)
+renewaire.com/specifications                                                                                                   Solid state speed control kit - 115V, qty. 1,
+                                                                          Typical Airflow Range: 240-500 CFM
+                                                                                                                                  208-230V, qty. 1
+                                                                          AHRI 1060 Certified Core: One L85-G5                  RA/FA Horizontal plenum box - RTC/RTH configuration
+                                                                                                                               RA/FA Vertical and horizontal plenum box
+                                                                          Standard Features:
+                                                                          Non-fused disconnect                                    - RTR/RTF configuration
+                                                                          24 VAC transformer/relay package                     Rooftop adapter transition paint - white, custom colors
+                                                                                                                               Roof curb - standard 14"
+                                                                          Filters:                                             Curb wind clip
+                                                                          Total qty. 2, MERV 8: 14" x 20" x 2"                 Engineered combo curb for Carrier RTU
+                                                                                                                               Engineered combo curb for Trane RTU
+                                                                          Unit Dimensions & Weight:                            Digital time clock - wall mount (TC7D-W),
+                                                                          75" L x 36 1/2" W x 19 1/4" H
+                                                                          184-243 lbs., varies by option(s)                       in exterior enclosure (TC7D-E)
+                                                                                                                               Carbon dioxide sensor/control -
+                                                                          Max. Shipping Dimensions & Weight (on pallet):
+                                                                          96" L x 47" W x 25" H                                   wall mount (CO2-W), duct mount (CO2-D)
+                                                                          350 lbs.                                             IAQ sensor - wall mount (IAQ-W),
+
+                                                                          Motor(s), choice of:                                    duct mount (IAQ-D)
+                                                                          Qty. 1, 0.6 HP (standard single phase)               Motion occupancy sensor/control -
+                                                                          Qty. 1, 0.5 HP (standard three phase)
+                                                                                                                                  ceiling mount (MC-C), wall mount (MC-W)
+                                                                          Options:                                             Smoke detector - duct mount (SD-D)
+                                                                          Qty. 1, Variable Speed/ECM - Direct Drive Motors     Electric duct heater - EK series (1–175 kW);
+
+                                                                             (see EV450IN EC Motor submittal) -                   designed for indoor ductwork installation only
+                                                                             0.5 HP, 120V/1Ph/60HZ,
+                                                                             0.5 HP, 208-230V/1Ph/60HZ
+                                                                          Fused disconnect
+                                                                          Integrated programmable controls -
+                                                                             enhanced, premium
+                                                                          Qty. 2, Factory mounted filter alarms -
+                                                                             both airstreams
+                                                                          Double wall construction
+                                                                          Exterior paint - white, custom colors
+
+                                                                          Note: Indirect Gas-Fired Duct Furnace is not available on the EV450RT.
+
+ELECTRICAL DThAeTrmAal Performance Ratings G5 2015.2.xlUsxNIT PERFORMANCEEV450 (IOM)
+
+                                      Min.                       Max.                        Airflow CFM       ESP in H20                                         Watts
+                Phase FLA Cir.                               Overcurrent
+HP Volts HZ                                                  Protection                           240            1.00                                   1P                               3P
+                                      Amps                                                        375            0.75                             425                                         243
+0.6 120 60                                                      Device                            450            0.50                             493                                         341
+0.6 208-230 60  Single 7.2 9.0                                    15                              500            0.25                             534                                         412
+0.6 277 60      Single 3.9-3.6 4.9                                                                550            0.00                             563                                         461
+0.5 208-230 60  Single 3.5 4.4                                    15                                                                              593                                         516
+0.5 460 60      Three 1.7-1.5 2.1
+                Three 0.8 1.0                                     15      Note: Watts is for the entire unit.
+                                                                          Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+                                                                  15
+
+                                                                  15
+
+                                                                          CORE PERFORMANCE
+
+                                                                                                         Airflow (CFM)
+
+                                                                          Effectiveness (%)       200    300  400         500  600
+
+                                                                                             90%
+
+                                                                                             70%
+
+                                                                                             50%
+
+                                                                                             30%
+                                                                                                    At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+     Specifications may be subject to change without notice.
+8 RENEWAIRE.COM 1.800.627.4499
+                                                                     EV450RT Energy Recovery Ventilator Standaarrdd or EC Motor Option
+
+                                                                                               CURB EV450                                                         11 3/4"              74 3/4" Overall                              RA Opening     ABBREVIATION
+                                                                                                                                                                                        48 7/8" Case                                11 3/4" X 13"  EA: Exhaust Air to outside
+                                                                                                   45 3/8" O.D.                                                                                                                     (Triangular)   OA: Outside Air intake
+                                                                                                                                                                                                                                                   RA: Room Air to be exhausted
+                                                                     27 1/2" I.D.          FA                    RA                  31 1/4" O.D.                                                                    31 3/8"FA Opening             FA: Fresh Air to inside
+                                                                           13"   A                                            A                          22 3/4"                                                     5 1/2" X 6 1/4"
+                                                                                                                                                                                                                                                   INSTALLATION ORIENTATION
+                                                                                                                                                                                                                                                   Unit must be installed in orientation
+                                                                                                                                                                                                                                                   shown.
+
+                                                                                                                                                                                                                                                   NOTE:
+                                                                                                                                                                                                                                                   1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                   DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                   NEAREST EIGHTH OF AN INCH.
+
+                                                                                                                                                                                                                                                   2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                   TO CHANGE WITHOUT NOTICE.
+
+                                                                     12 5/8"                        16 1/2"                          12 5/8"                      12 1/4"                                        3"
+                                                                                                 41 5/8" I.D.
+                                                                                                                                                                                       TOP VIEW
+                                                                                               TOP VIEW
+                                                                                                                                                                                       48 3/8" Minimum
+                                                                     CURB CROSS-SECTION A-A (TYP.)                                                                                       Service Area
+
+                                                                                   1 1/2" X 1/4"               1 7/8"                14"                                                  Door
+                                                                                   Neoprene Gasket                                                        46"                             Swing
+                                                                                                                                                              14 1/4" Minimum
+                                                                                   3/4" X 3 1/2"                                                                  Service Area
+                                                                                   Wooden Nailer                                                                     (Door can be
+                                                                                                                                                                         Removed from
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 9                                       3"                                                                 Hinges)
+
+                                                                                               SECTION A-A                                                                                                                                         36 1/2" Overall
+                                                                                                                                                                                                                                                    34 1/4" Case
+
+                                                                     19 1/4" Case                                        19 1/4"                 EA                                                                          OA
+                                                                                                                            Overall
+                                                                                                                                     CL 5 1/4" Power In                                                              Disconnect
+                                                                     1 5/8"                      30 5/8"                             CL 4 1/8" Control In                                  FA                        Switch                               CL 4 7/8" Control In
+                                                                       Typ.                    Lifting Lugs                          (2) 7/8" Holes                                                              RA                                      CL 4 1/4" Power In
+                                                                                                                                     for Wiring in
+                                                                                                                                     Bottom of Unit                                    44 5/8" Lifting Lugs                                         RIGHT VIEW
+
+                                                                                         LEFT VIEW                                                                                     FRONT VIEW                                                  UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                                                                                   Must be mounted as shown. Airstreams can not be
+                                                                        AIRFLOW CONFIGURATION                                                                                                                                                      switched. Rooftop adapter accessories can be used
+                                                                                                                                                                                                                                                   to provide RTR and RTF (45RTRF) or RTH and RTC
+                                                                     MAovadilaeblle: aEsVsh4ow5n0inRdTimension drawing.                                                                                                                            (45RTCH) airflow.
+                                                                     Drawing Type: Unit Dimension
+                                                                     Version: JUL17                                                                                                                                                                 EV-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+EV 450RT                                                                   Energy Recovery Ventilator
+                                                                           EC Motor Option
+
+ROOFTOP UNIT                                                               SPECIFICATIONS
+
+Download specification at:                                                 Ventilation Type:                                                                                       Accessories:
+renewaire.com/specifications                                               Static plate, heat and humidity transfer                                                                Filters - MERV 13, 2" (shipped loose)
+                                                                                                                                                                                   Potentiometer speed control - remote installed
+                                                                           Typical Airflow Range: 200-510 CFM                                                                       RA/FA Horizontal plenum box
+
+                                                                           AHRI 1060 Certified Core: One L85-G5                                                                        - RTC/RTH configuration
+                                                                                                                                                                                   RA/FA Vertical and horizontal plenum box
+                                                                           Standard Features:                                                                                      - RTR/RTF configuration
+                                                                           Non-fused disconnect                                                                                    Rooftop adapter transition paint - white,
+                                                                           24 VAC transformer/relay package
+                                                                                                                                                                                      custom colors
+                                                                           Filters:                                                                                                Roof curb - standard 14"
+                                                                           Total qty. 2, MERV 8: 14" x 20" x 2"                                                                    Curb wind clip
+                                                                                                                                                                                   Engineered combo curb for Trane RTU
+                                                                           Unit Dimensions & Weight:                                                                               Engineered combo curb for Carrier RTU
+                                                                           75" L x 36 1/2" W x 19 1/4" H                                                                           Digital time clock - wall mount (TC7D-W),
+                                                                           187-246 lbs., varies by option(s)
+                                                                                                                                                                                      in exterior enclosure (TC7D-E)
+                                                                           Max. Shipping Dimensions & Weight (on pallet):                                                          Carbon dioxide sensor/control -
+                                                                           96" L x 47" W x 25" H
+                                                                           350 lbs.                                                                                                   wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                                                                   IAQ sensor - wall mount (IAQ-W),
+                                                                           Motor(s):
+                                                                           Qty. 1, 0.5 HP, Direct drive EC blower/                                                                    duct mount (IAQ-D)
+                                                                                                                                                                                   Motion occupancy sensor/control -
+                                                                              motor package
+                                                                                                                                                                                      ceiling mount (MC-C), wall mount (MC-W)
+                                                                           Options:                                                                                                Smoke Detector - duct mount (SD-D)
+                                                                           Fused disconnect                                                                                        Electric duct heater - EK series (1–175 kW);
+                                                                           Integrated programmable controls -
+                                                                                                                                                                                      designed for indoor ductwork installation only
+                                                                              enhanced, premium
+                                                                           Qty. 2, Factory mounted filter alarms -
+
+                                                                              both airstreams
+                                                                           Double wall construction
+                                                                           Exterior paint - white, custom colors
+
+EC MOTOR OPTION OPERATING RANGE                                            Note: Indirect Gas-Fired Duct Furnace is not available on the EV450RT.
+
+                                                                                                                      EV450-RT ECM
+
+                                                                                                       1.25                                                      470
+                                                                                                                                                          436
+                    EV450RT EC MOTOR
+         Sample Points Depicted in Larger Dots
+
+    Airflow    External Static   Unit Power                                                                      1.00                                                             502
+    (CFM)        Pressure      Consumption                                                                                                                            451
+                                                                                                                                                   337
+              (Inches Water       (Watts)
+                 Column)
+
+    217               0.07                                    78           External Static Pressure (in. w.g.)                                                                         516
+                                                                                                                                                                            447
+    305     Thermal0P.1e6rformance Ratin1g8s0G5 2015.2.xlsx                                                     0.75                                   324
+
+                                                                                                                                              EV450 (IOM)
+
+    375               0.25                                    301                                                                        204                                                 521
+
+    435               0.34                                    426                                                                                         317                      438
+
+    467               0.40                                    520                                               0.50                     196
+                                                                                                                                                                       310
+    200               0.20                                    85                                                                                                                        426       520
+                                                                                                                                             191
+
+    274               0.43                                    196                                               0.25 85                       186              301
+                                                                                                                          82                      180              289
+    332               0.67                                    324                                                           80                       174                                     415       514 (Watts)
+
+    376               0.90                                    451                                                             78
+                                                                                                                                77
+    395               1.00                                    502
+
+                                                                                                                0.00
+
+Note: Watts is for the entire unit.                                                                                   200           250       300         350               400            450         500          550  600
+Note: Airflow performance includes effect of clean, standard filter
+supplied with unit.                                                                                                                                                 Airflow (cfm)
+                                                                                                                           = Actual tested sample points
+ELECTRICAL DATA
+                                                                           CORE PERFORMANCE
+
+                               Min.                               Max.                                                                   Airflow (CFM)
+                                Cir.                          Overcurrent
+HP  Volts   HZ Phase  FLA      Amps                           Protection                                              200           300            400         500                    600
+
+                                                                 Device    Effectiveness (%)                    90%
+
+0.5 120 60 Single 8.1 10.1                                        15
+
+0.5 208-230 60 Single 4.8 6.0                                     15                                            70%
+
+                                                                                                                50%
+
+                                                                                                                30%
+                                                                                                                        At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+      Specifications may be subject to change without notice.
+10 RENEWAIRE.COM 1.800.627.4499
+                                                                      EV450RT Energy Recovery Ventilator EStCanMdoatrodr oOrpEtiConMotor Option
+
+                                                                                                CURB EV450                                                         11 3/4"              74 3/4" Overall                              RA Opening     ABBREVIATION
+                                                                                                                                                                                         48 7/8" Case                                11 3/4" X 13"  EA: Exhaust Air to outside
+                                                                                                    45 3/8" O.D.                                                                                                                     (Triangular)   OA: Outside Air intake
+                                                                                                                                                                                                                                                    RA: Room Air to be exhausted
+                                                                      27 1/2" I.D.          FA                    RA                  31 1/4" O.D.                                                                    31 3/8"FA Opening             FA: Fresh Air to inside
+                                                                            13"   A                                            A                          22 3/4"                                                     5 1/2" X 6 1/4"
+                                                                                                                                                                                                                                                    INSTALLATION ORIENTATION
+                                                                                                                                                                                                                                                    Unit must be installed in orientation
+                                                                                                                                                                                                                                                    shown.
+
+                                                                                                                                                                                                                                                    NOTE:
+                                                                                                                                                                                                                                                    1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                    DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                    NEAREST EIGHTH OF AN INCH.
+
+                                                                                                                                                                                                                                                    2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                    TO CHANGE WITHOUT NOTICE.
+
+                                                                      12 5/8"                        16 1/2"                          12 5/8"                      12 1/4"                                        3"
+                                                                                                  41 5/8" I.D.
+                                                                                                                                                                                        TOP VIEW
+                                                                                                TOP VIEW
+                                                                                                                                                                                        48 3/8" Minimum
+                                                                      CURB CROSS-SECTION A-A (TYP.)                                                                                       Service Area
+
+                                                                                    1 1/2" X 1/4"               1 7/8"                14"                                                  Door
+                                                                                    Neoprene Gasket                                                        46"                             Swing
+                                                                                                                                                               14 1/4" Minimum
+                                                                                    3/4" X 3 1/2"                                                                  Service Area
+                                                                                    Wooden Nailer                                                                     (Door can be
+                                                                                                                                                                          Removed from
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 11                                       3"                                                                 Hinges)
+
+                                                                                                SECTION A-A                                                                                                                                         36 1/2" Overall
+                                                                                                                                                                                                                                                     34 1/4" Case
+
+                                                                      19 1/4" Case                                        19 1/4"                 EA                                                                          OA
+                                                                                                                             Overall
+                                                                                                                                      CL 5 1/4" Power In                                                              Disconnect
+                                                                      1 5/8"                      30 5/8"                             CL 4 1/8" Control In                                  FA                        Switch                               CL 4 7/8" Control In
+                                                                        Typ.                    Lifting Lugs                          (2) 7/8" Holes                                                              RA                                      CL 4 1/4" Power In
+                                                                                                                                      for Wiring in
+                                                                                                                                      Bottom of Unit                                    44 5/8" Lifting Lugs                                         RIGHT VIEW
+
+                                                                                          LEFT VIEW                                                                                     FRONT VIEW                                                  UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                                                                                    Must be mounted as shown. Airstreams can not be
+                                                                         AIRFLOW CONFIGURATION                                                                                                                                                      switched. Rooftop adapter accessories can be used
+                                                                                                                                                                                                                                                    to provide RTR and RTF (45RTRF) or RTH and RTC
+                                                                      MAovadilaeblle: aEsVsh4ow5n0inRdTimension drawing.                                                                                                                            (45RTCH) airflow.
+                                                                      Drawing Type: Unit Dimension
+                                                                      Version: JUL17                                                                                                                                                                 EV-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+EV 450RT                                                                  Energy Recovery Ventilator
+                                                                          Standard or EC Motor Option
+
+DUCTING ACCESSORIES                                             RTV
+
+Rooftop Curb (45Curb)                                                                                                                                      EV450RT                                        ID = 13" X                                                   45 3/8"
+Standard roof curb shown (available option).                                                                                                    CURB EV450                                                   13" TYP
+                                                                                                                                                                                                                                                                       74 3/4" Overall
+                                                            EA                                                                                     45O3/A8" O.D.                                                           11 3/4"
+                                                                                                                                                                                                                                                                       48 7/8" Case
+
+                                                                                                                                                                                                                                                          FA                            R
+
+                                                                                                          27 1/2" I.D.                                       RA
+                                                                                                                13"
+
+                                                                                                                                                                               31 1/4" O.D.
+                                                                                                                                                                                                   22 3/4"
+                                                                11"                                                                      FA                                                      1 7/8" TYP
+
+                                                                                       FA                               RA
+
+                                                                                                                        A                           ROOF CURB A
+
+                                                                    EV450RT WITH STANDARD ROOF
+
+                                                                                  CURB (45CURB12)5/8"                                                16 1/2"                                     12 5/8"              12 1/4"                                                         TOP V3"I
+                                                                                                                                                  41 5/8" I.D.
+                                                                                                                                                                                                                                                          STANABDBTRAEOVRIPADTVIORINEOWOF C
+                                                                                                                                                TOP74V3I/E4"WOverall
+                                   CURB EV450                                                                                                                                                                         RA Opening                          EA: Exhaust Air to outsid
+                                                                                                                                                        48 7/8" Case                                                                                      OA: Outside Air intake
+                                       45 3/8" O.D.
+                                                                                                                        11 3/4"                                                                                       11 3/4" X 13"                       RA:4R8o3o/m8" AMirintiombuemexh
+                                                                                                                                                                                                                      (Triangular)                        FA: FrSeeshrvAicier tAorienaside
+
+                                                                                                          CURB CROSS-SECTION A-A (TYP.)                                                                                                                   INSTALLATION ORIENTAT
+                                                                                                                                                                                                                                                          Unit must be installed in
+         27 1/2" I.D.          FA                                         RA               31 1/4" O.D.                 1 1/2" X 1/4"                        1 7/8"                              14"                                                      shown.
+               13"   A                                                                 A                       22 3/4"                                                                                                46"
+                                                                                                                        Neoprene Gasket                                                                                   14 1/4"31Mi3n/i8"mum            NOTE:
+                                                                                                                                                                                                                              Service Area
+                                                                                                                                                    UNLESS OTHERWISE SPECIFIED, DIMENSIONS                                       (Door can be             1. UNLESS OTHERWISE SP
+                                                                                                                                                                                                                                     Removed from
+                                                                                                                        3/4" X 3 1/2"               AND TOLERANCES ARE IN INCHES.                                                        Hinges)          DIMENSIONS ARE ROUN
+                                                                                                                                                                    LINEAR ± .015                         RenewAire                                       NEAREDSoToErIGHTH OF AN
+
+                                                                                                                        Wooden Nailer                        HOLE SIZE ± .005
+                                                                                                                                                                        < ± 3 DEG
+                                                                                                                                                                                                          TITLE:
+                                                                                                                                                                      63                                                                                  2. SPECSwIFiInCgATIONS MAY
+                                                                                                                                                                            SURFACE FINISH                450RT ADAPTER CURB TDOIMCHEANNSGIOE NWSITHOUT N
+
+                                                                                                                                                       3"                                                 DO NOT SCALE DRAWING. REMOVE DRAWN BY: DATE:                                  D
+
+                                                                                                                                                    MATERIAL:
+
+         12 5/8"                                                16 1/2"               12 5/8"                           12 1/4"                 SECTSEIOE BNILAL O-AF  MATERIALS                          ALLFBAURROS. BpREeAKnSiHnAgRP EDGES.            KWE              4-16-02      4
+                                                                                                                                                                                                          5 1/2" X 6 1/4" APPLICABLE STANDARDS: DIM. AND
+         LEVEL DESCRIPTION                                                                        DATE                            BY                FINISH:                   3"                                                                          CHECKED BY:  DATE:             S
+                                                                                                                                                                                                          TOL. ANSI Y14.5
+                                        41 5/8"                     I.D.                                                                                                                                                                                  -                 -
+         MAY16               REFORMAT                                                             5/20/16 KMC                                       _TOP VIEW
+
+                                                              TOP VIEW                14"
+                                                                                                           46"
+                                                                                                               14 1/4" Minimum                      48 3/8" Minimum         19 1/4"
+                                                                                                                   Service Area                       Service Area             Overall
+                                                                                                                     (Door can be 19 1/4" Case
+    RTR/RTCFURB CROSS-SECTION A-A (TYP.)                                                                                  Removed from                                                                            EA
+                                                                                                                              Hinges)
+                       1 1/2" X 1/4"                                      1 7/8"
+
+Rooftop Adapter for RNeTopRrenae nGadskeRt TF                            Orientations             stack1tT5hy/ep8".optional                         30 5/8"                 on              the         CL 5 1/4" Power In                                    FA
+For horizontal connection of eithe3r/4t"hXe3F1r/e2s" h Air duct          or the Return Air duct,                                                                                                                                                                                    RA
+                                                                                                                                                RLTifFtin/RgTLuRgAs dapter                       stanCdLa4rd1/r8o" oCfocnutrrobl .In
+                                                                                                                                                                                                                                                          44 5/8" Lifting Lugs
+                                                       Wooden Nailer                                                                                Door                                         (2) 7/8" Holes
+                                                                                                                                                    Swing                                        for Wiring in                                            FRONT VIEW
+Duct openings to be field cut into adapter. Opening location and size is flexible.
+                                                                                                                                                                                                                                                                 36 1/2" Overall
+                                                                3"                                                                                                                               Bottom of Unit
+
+                                   SECTION A-A                                                                                                  LEFT VIEW                                                             EV450RT
+
+                                                                                                  Model: EV450RT                                                                                                                                                       34 1/4" Case
+
+         19 1/4" Case                                                             OA              Drawing Type: Unit Dimension                                                                                    OA
+
+EA                                                                        19 1/4"                 VEeArsion: JUL17
+                                                                             Overall
+                                                                                                  EA                                                                                                              OA
+
+     FA                                                                                                                                         FA                                               RA                   14"
+
+28"      1 5/8"                           RA                                                 CL 5 1/4" Power In28"                                  FA                                                    Disconnect                                                        CL 4 7/8" Con
+           Typ.                      30 5/8"                                      ADAPTECRL 4(F1/U8L" CLYontrol In                                                                                                                                                          CL 4 1/4" Powe
+                                   Lifting Lugs                                                                                                                                             RA            Switch
+                                                                                                                                                                                                                                                                       RIGHT VIEW
+                                                                                           INS(U2)LA7T/E8D" H)oles
+
+                                                                                           for Wiring in                                            44 5/8" Lifting Lugs
+
+     E(V4455R0TRRTF)WAITNHDRLCTEFUF/TRRBVTRI(E4AW5DCAUPRTBE)R                              Bottom of Unit                         EV450RTFRWOITNHTRVTFIE/WRTR ADAPTER                                                 ROOF CURB
+                                                                                                                                   (45RTRF) AND CURB (45CURB)
+
+         ModINeRl: TERVC45O0NRTFIGURATION                                                                                                       IN RTF CONFIGURATION
+
+         Drawing Type: Unit Dimension
+
+         Version: JUL17
+
+      Specifications may be subject to change without notice.                          UNLESS OTHERWISE SPECIFIED, DIMENSIONS                     RenewAire                                                                                                         4510 Helgesen Dr.
+12 RENEWAIRE.COM 1.800.627.4499                                                                AND TOLERANCES ARE IN INCHES.                                                                                                                                  Madison, WI 53718 USA
+                                                                                                                                                TITLE:
+                                                                                                               LINEAR ± .015                                                                                                                                    TEL: (608) 221-4499
+                                                                                                           HOLE SIZE ± .005                        450RT ADAPTER CURB DIMENSIONS                                                                                FAX: (608) 221-2824
+                                                                                                                                                                                                                                                          TOLL FREE: (800) 627-4499
+                                                                                                                       < ± 3 DEG                DO NOT SCALE DRAWING. REMOVE DRAWN BY: DATE:
+                                                                                                                                                                                                                      DRAWING NO.                                      REVISION
+                                                                                                        63
+                                                                                                              SURFACE FINISH
+
+                                                                                      MATERIAL:
+                         EV 450RT                                                                      Energy Recovery Ventilator
+                                                                                                       Standard or EC Motor Option
+
+                      DUCTING ACCESSORIES
+
+                           RTC/RTH
+
+                      Rooftop Adapter for RTC and RTH Orientations
+                      The RTH/RTC Adapter allows horizontal connection of both the Fresh Air and the Return Air ducts. It is also possible to connect the adapter directly to the
+                      return plenum of most rooftop units (openings must be cut into RTU). Duct openings to be field cut into adapter. Opening location and size is flexible.
+                      31 3/8"
+                                        ABBREVIATION
+                                                                                                                                                 EV-SERIES
+                         RA Opening     EA: Exhaust Air to outside
+                                        OA: Outside Air intake
+
+RA                       11 3/4" X 13"  RA: Room Air to be exhausted
+
+                         (Triangular)   FA: Fresh Air to inside
+
+              31 1/4"                   UINnSitTAmLuLAstTbIOeENiAnOstRaIlEleNdTAinTIoOriNentation                                                   OA
+
+                                        shown.                                                                                                                                           OA
+
+                                ADAPTE1NR.OUTN(EFL: EUSSLOLYTHERWISE SPECIFIED,                    FA   RA  15 1/2"                                                                        38"
+                                       INSDNUEIMALERANESSTTIOEENIDGSH)ATRHEORFOAUNNDINECDHT.O THE
+
+                                        2. SPECIFICATIONS MAY BE SUBJECT                                                                                                                                      RA
+                                        TO CHANGE WITHOUT NOTICE.                                                                                                                                                 FA
+
+IEW           FA Opening
+
+              5 1/2" X 6 1/4"                     17 1/2"                                                    46"
+CURB (14" HIGH)                                                                                    EV450RT WITH ADAPTER (45RTCH)
+
+de
+
+hausted
+
+TION                  ABBREVIATIONS
+n orientation         EA: Exhaust Air to outdoors
+
+OA: Outdoor Air intake PECIFIED, 4510 Helgesen Dr.                                                      UNLESS OTHERWISE SPECIFIED, DIMENSIONS      RenewAire                                                          4510 Helgesen Dr.
+                              Madison, WI 53718 USA                                                              AND TOLERANCES ARE IN INCHES.                                                                    Madison, WI 53718 USA
+
+RA: Room Air to be exhausted NDED TO THETEL: (608) 221-4499                                                                      LINEAR ± .015                                                                      TEL: (608) 221-4499
+                                                                                                                             HOLE SIZE ± .005                                                                       FAX: (608) 221-2824
+N INCH. FAX: (608) 221-2824                                                                                                                                                                                   TOLL FREE: (800) 627-4499
+                          TOLL FREE: (800) 627-4499                                                                                      < ± 3 DEG
+
+Y BE SUBJECT          FA: Fresh Air to inside                                                                             63                        TITLE:
+                                                                                                                                SURFACE FINISH
+NOTICE.                                                                                                                                             450RT ADAPTER CURB DIMENSIONS
+                                                                                                        MATERIAL:
+DRAWING NO.           REVISION                                                                                                                      DO NOT SCALE DRAWING. REMOVE    DRAWN BY: DATE:           DRAWING NO.  REVISION
+                                                                                                        SEE BILL OF MATERIALS                       ALL BURRS. BREAK SHARP EDGES.
+450RT_adaptcurb_DIMS_MLEAVEYL16 DESCRIPTION 36 1/2" Overall                                                                                                                         KWE              4-16-02  450RT_adaptcurb_DIMS_JUN16
+                                                                                                        FINISH:                                     APPLICABLE STANDARDS: DIM. AND
+                                                                             DATE                  BY                                               TOL. ANSI Y14.5                 CHECKED BY: DATE:         SCALE:       SIZE:          SHEET:
+                                                                             6/21/16                    _                                                                                                                                  3 OF 3
+SCALE:         SIZE:       SHJEUETN: 16 REFORMAT                                                   KMC                                                                              -                  -             1/42        A
+
+        1/42          A    1 OF 3                 34 1/4" Case
+
+                       OA                              CL 4 7/8" Control In
+                                                       CL 4 1/4" Power In
+               Disconnect
+               Switch                             RIGHT VIEW
+
+ ntrol In
+   er In
+
+W
+
+                                                                                                                                                   Specifications may be subject to change without notice.
+                                                                                                            FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 13
+SPECIFICATIONS & DIMENSIONS
+
+HE 1XINH                                                                   Energy Recovery Ventilator
+                                                                           Standarrdd & Bypass Economizer Option
+
+INDOOR UNIT                                                                SPECIFICATIONS                                                     Options:
+                                                                                                                                              Qty. 2, Variable Speed/ECM - Direct Drive Motors
+Download specification at:                                                 Ventilation Type:
+renewaire.com/specifications                                               Static plate, heat and humidity transfer                              (see HE1XINH EC Motor submittal) -
+                                                                                                                                                 0.5 HP, 120V/1Ph/60HZ,
+                                                                           Typical Airflow Range: 250-925 CFM                                     0.5 HP, 208-230V/1Ph/60HZ
+                                                                                                                                              Independent blower control
+                                                                           AHRI 1060 Certified Core: One L125-G5                               Fused disconnect
+                                                                                                                                              Integrated programmable controls -
+                                                                           Standard Features:                                                    enhanced, premium
+                                                                           Non-fused disconnect                                               Bypass economizer damper
+                                                                           24 VAC transformer/relay package                                      (see bypass DIM drawing) -
+                                                                           Cross-core differential pressure ports                                dry-bulb temperature controls (standard),
+                                                                                                                                                 enthalpy controls (option)
+                                                                           Filters:                                                           Low-leakage motorized isolation dampers -
+                                                                           Total qty. 2, MERV 8: 20" x 20" x 2"                                  OA, RA or both airstreams
+                                                                                                                                              Qty. 2, Factory mounted filter alarms -
+                                                                           Unit Dimensions & Weight:                                             both airstreams
+                                                                           54 3/4" L x 23 3/4" W x 35 3/4" H                                  Double wall construction
+                                                                           204-275 lbs., varies by option(s)                                  Exterior paint - white, custom colors
+
+                                                                           Max. Shipping Dimensions & Weight (on pallet):                     Accessories:
+                                                                           63" L x 30" W x 56" H                                              Filters - MERV 13, 2" (shipped loose)
+                                                                           325 lbs.                                                           Backdraft damper 12"
+                                                                           Accessories box shipped loose on top of unit.                      Motorized isolation damper - both airstreams
+                                                                                                                                              Wall cap 12" - galvanized, paintable galvanneal
+                                                                           Motor(s):                                                          Solid state speed control kit - 115V,
+                                                                           Qty. 2, 0.75 HP ea., Direct drive blower/standard
+                                                                                                                                                 208-230V (1 required per motor)
+                                                                              motor packages                                                  Digital time clock - wall mount (TC7D-W),
+
+              Thermal Performance Ratings G5 2015.2.xlsx                                                      HE1X (IOM)                         in exterior enclosure (TC7D-E)
+                                                                                                                                              Carbon dioxide sensor/control -
+
+                                                                                                                                                 wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                              IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                 duct mount (IAQ-D)
+                                                                                                                                              Motion occupancy sensor/control -
+
+                                                                                                                                                 ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                              Smoke Detector - duct mount (SD-D)
+                                                                                                                                              Electric duct heater - RH series (1-11.5 kW);
+
+                                                                                                                                                 EK series (1–175 kW);
+                                                                                                                                                 designed for indoor ductwork installation only
+                                                                                                                                              Indirect gas-fired duct furnace - GH series
+                                                                                                                                                 (50-400 MBH), installed downstream of any fans
+
+AIRFLOW PERFORMANCE
+
+    Motor HP                                                                                  External Static Pressure (Inches Water Column)
+
+    Phase               0.0                                   0.25                            0.5             0.75              0.9              1.25                                         1.5
+
+    0.75        970 CFM                 925 CFM                              860 CFM                            795 CFM           750 CFM     635 CFM                                     480 CFM
+Single Phase  1,490 Watts             1,375 Watts                          1,270 Watts                        1,160 Watts       1,090 Watts   950 Watts                                   825 Watts
+
+    0.75        970 CFM                 925 CFM                              860 CFM                            795 CFM           750 CFM     635 CFM                                     480 CFM
+Three Phase   1,246 Watts             1,158 Watts                          1,039 Watts                          928 Watts         856 Watts   691 Watts                                   509 Watts
+
+Note: Watts is for the entire unit (two motors).
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                            CORE PERFORMANCE
+
+HP  Volts     HZ Phase   FLA   Min.                               Max.                                   Airflow (CFM)
+                         per    Cir.                          Overcurrent
+                        motor  Amps                           Protection   Effectiveness (%)        200  400  600          800  1000
+                                                                                              90%
+                                                                 Device
+
+0.75 120 60 Single 9.0 20.3                                   25
+
+0.75 208-230 60 Single 4.5 10.1                               15                              70%
+
+0.75 277 60 Single 3.9 8.8                                    15                              50%
+
+0.75 208-230 60 Three 1.7-2.3 5.2                             15
+
+0.75 460 60 Three 1.15 2.6                                    15                              30%
+                                                                                                     At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+      Specifications may be subject to change without notice.
+14 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1XINH Energy Recovery Ventilator Standaarrdd or EC Motor Option
+
+                                                                                         21 3/4" Case         29"                                                                                                                   ABBREVIATIONS
+                                                                                                                                                                                                                                    EA: Exhaust Air to Outside
+                                                                                                       Door                                                                                                                         OA: Outside Air Intake
+                                                                                                       Swing                                                                                                                        RA: Room Air to be Exhausted
+                                                                              54 3/4" Overall                                                                                                                                       FA: Fresh Air to Inside
+                                                                                                                                                49" MinimumDoor                       12"   ISOMETRIC VIEW                          INSTALLATION ORIENTATION
+                                                                                                                                                    Service AreaSwing                                                               Unit may be installed in any
+                                                                                                                                                       (Doors can be                                                                orientation.
+                                                                                                                                                           Removed from Hinges.)      TYP.                            9"            NOTE
+                                                                                                                                                                                                                                    1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                      TYP.          DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                    NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                    2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                    TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                                                    3.DAMPERS SHIPPED LOOSE, FIELD
+                                                                                                                                                                                                                                    INSTALLATION REQUIRED.
+
+                                                                                                                           Alternate                                                                    6"
+                                                                                                                           Power Wiring
+                                                                      Alternate                                            Inlet 7/8"                                                                   TYP.
+                                                                      Control Wiring
+                                                                      Inlet 7/8"                                        20 1/8" Minimum                                               FRONT VIEW                  RIGHT VIEW
+                                                                                                                          Service Area
+                                                                               TOP VIEW                                  (Doors can be                                                (OA/RA) DAMPER OPTION (QTY.2)
+                                                                                                                                                                                            (SHIPPED LOOSE)
+                                                                                                                   Removed from Hinges.)
+
+                                                                                                                                                                                                  SCALE 1:16
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 15                     23 3/4"                                                                                               Door-interlocked   2 7/8" Typ.                              12"
+                                                                                         Overall                                                                                                                                    OA Isolation Typ.
+                                                                                                                                                                                               Disconnect Switch  Pressure          Damper
+                                                                      12 7/8"                          Control Wiring                                                                       49 1/8"               Ports (4) Typ.    Wiring Conn.                10 3/8"
+                                                                                                       Inlet 7/8"                                                                            Case
+
+                                                                                                                                                                                  EA                              OA                                            27 1/2"
+                                                                                                                                                                                                                                                                     35 5/8" Overall
+                                                                      27 5/8"                          Power Wiring                                                                                                   34 7/8" Case  RA Isolation
+                                                                            8 7/8" Typ.                Inlet 7/8"                                                                                                                   Damper
+                                                                                                                                                                                                                  RA                Wiring Conn.
+                                                                                                                                       FA
+
+                                                                                                          12"
+                                                                                                       Typ.
+
+                                                                      8 5/8"                                                                                                                Leveling              3/4"-1 7/8" Typ.                                        10 3/8"
+                                                                                                                                                                                            Feet (4)
+                                                                                         LEFT VIEW                                                                                                                                    RIGHT VIEW
+                                                                                                                                                                                            FRONT VIEW
+                                                                                                                                                                                                                                    UNIT MOUNTING & APPLICATION
+                                                                      MAoIRdFeLlO: W HEC1OXNINFIHGURATION                                                                                                                           Can be mounted in any orientation. RA/EA airstream
+                                                                      DAravaiwlabilenags shToywpn ined:imUennsioitn dDraiwminge. nsion                                                                                              can be switched with OA/FA airstream unless
+                                                                      Version: MAY18                                                                                                                                                certain options are selected.
+
+                                                                                                                                                                                                        HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 1XINH                                                             Energy Recovery Ventilator
+                                                                     EC Motor Option
+
+INDOOR UNIT                                                          SPECIFICATIONS
+
+Download specification at:                                           Ventilation Type:                                                                                   Options:
+renewaire.com/specifications
+                                                                     Static plate, heat and humidity transfer                                                            Fused disconnect
+EC MOTOR OPTION OPERATING RANGE
+                          HE1XINH EC MOTOR                           Typical Airflow Range: 250-1,100 CFM                                                                 Integrated programmable controls -
+                                                                     AHRI 1060 Certified Core: One L125-G5                                                                   enhanced, premium
+
+                                                                                                                                                                         Bypass economizer damper
+
+                                                                     Standard Features:                                                                                     (see bypass DIM drawing) -
+                                                                     Non-fused disconnect                                                                                   dry-bulb temperature controls (standard),
+
+                                                                     24 VAC transformer/relay package                                                                       enthalpy controls (option)
+
+                                                                     Cross-core differential pressure ports                                                              Low-leakage motorized isolation dampers -
+
+                                                                     Filters:                                                                                               OA, RA or both airstreams
+                                                                     Total qty. 2, MERV 8: 20" x 20" x 2"                                                                Qty. 2, Factory mounted filter alarms -
+
+                                                                                                                                                                            both airstreams
+
+                                                                     Unit Dimensions & Weight:                                                                           Double wall construction
+
+                                                                     54 3/4" L x 23 3/4" W x 35 3/4" H                                                                   Exterior paint - white, custom colors
+
+                                                                     207-278 lbs., varies by option(s)                                                                   Accessories:
+
+                                                                     Max. Shipping Dimensions & Weight (on pallet): Filters - MERV 13, 2" (shipped loose)
+
+                                                                     63" L x 30" W x 56" H                                                                               Backdraft damper 12"
+
+                                                                     325 lbs.                                                                                            Motorized isolation damper - both airstreams
+
+                                                                     Accessories box shipped loose on top of unit.                                                       Wall cap 12" - galvanized, paintable galvanneal
+
+                                                                     Motor(s):                                                                                           Potentiometer speed control - remote installed
+                                                                     Qty. 2, 0.5 HP ea., Direct drive EC blower/                                                         Digital time clock - wall mount (TC7D-W),
+
+                                                                        motor packages                                                                                      in exterior enclosure (TC7D-E)
+                                                                                                                                                                         Carbon dioxide sensor/control -
+
+                                                                                                                                                                            wall mount (CO2-W), duct mount (CO2-D)
+
+                                                                                                                                                                         IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                                            duct mount (IAQ-D)
+
+                                                                                                                                                                         Motion occupancy sensor/control -
+
+                                                                                                                                                                            ceiling mount (MC-C), wall mount (MC-W)
+
+                                                                                                                                                                         Smoke Detector - duct mount (SD-D)
+
+                                                                                                                                                                         Electric duct heater - RH series (1-11.5 kW);
+
+                                                                                                                                                                            EK series (1–175 kW);
+
+                                                                                                                                                                            designed for indoor ductwork installation only
+
+                                                                                                                                                HE1X-IN ECM (HIondriVre)ct gas-fired duct furnace - GH series
+                                                                                                                                                                       (50-400 MBH), installed downstream of any fans
+
+                                                                                                          1.75
+
+         Sample Points Depicted in Larger Dots
+
+                External Static                                                                           1.50                                                     992
+                   Pressure                                                                                                                                918
+    Airflow                        Unit Power
+    (CFM)       (Inches Water    Consumption
+                   Column)
+                                    (Watts)                                                               1.25
+
+    324                0.04                             86           External Static Pressure (in. w.g.)                                              655                      1029
+                                                                                                                                                                       911
+    446         Thermal0P.0e7rformance Ratin1g5s0G5 2015.2.xlsx 1.00                                                                   HE1X (IOM)
+                                                                                                                                                                                     1075
+    647                0.15                             300                                                                                                 643            871
+
+    794                0.24                             564                                               0.75                                                                             1068
+
+                                                                                                                                       392                       599             852
+
+    929                0.33                             827
+
+    1019               0.41                             1042                                                                                    386              583                         1056
+                                                                                                                                                  359               572          839
+                                                                                                                                                      340
+    300                0.11                             91                                                0.50                                                                                   1042
+                                                                                                                                  173
+                                                                                                                                                                                      827
+
+    406                0.20                             160                                                                                                             564
+                                                                                                                                                                            560
+    579                0.42                             359                                               0.25                   164                 322                                   818     1029 (Watts)
+                                                                                                                       97          160                 300
+                                                                                                                                     156                  273
+    713                0.65                             599                                                                89          153
+                                                                                                                             85         150                       750
+    828                0.89                             871                                               0.00                            148       Airflow (cfm)
+                                                                                                               250                                                                         1000                  1250
+                                                                                                                                           500
+
+    883                1.00                             1075                                                         = Actual tested sample points
+
+Note: Watts is for the entire unit.                                  CORE PERFORMANCE
+Note: Airflow performance includes effect of clean, standard filter
+supplied with unit.                                                                                                                    Airflow (CFM)
+
+ELECTRICAL DATA                                                      Effectiveness (%)                          200        400         600            800             1000
+
+                                                                                                          90%
+
+HP  Volts   HZ  Phase   FLA      Min.                       Max.                                          70%
+                        per       Cir.                  Overcurrent
+                       motor     Amps                   Protection
+
+                                                           Device
+
+0.5 120 60 Single 8.1 18.2                                   25                                           50%
+
+0.5 208-230 60 Single 4.8 10.8                               15                                           30%
+                                                                                                                 At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+Specifications may be subject to change without notice.
+
+16 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1XINH Energy Recovery Ventilator EStCanMdoatrodr oOrpEtiConMotor Option
+
+                                                                                         21 3/4" Case         29"                                                                                                                   ABBREVIATIONS
+                                                                                                                                                                                                                                    EA: Exhaust Air to Outside
+                                                                                                       Door                                                                                                                         OA: Outside Air Intake
+                                                                                                       Swing                                                                                                                        RA: Room Air to be Exhausted
+                                                                              54 3/4" Overall                                                                                                                                       FA: Fresh Air to Inside
+                                                                                                                                                49" MinimumDoor                       12"   ISOMETRIC VIEW                          INSTALLATION ORIENTATION
+                                                                                                                                                    Service AreaSwing                                                               Unit may be installed in any
+                                                                                                                                                       (Doors can be                                                                orientation.
+                                                                                                                                                           Removed from Hinges.)      TYP.                            9"            NOTE
+                                                                                                                                                                                                                                    1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                      TYP.          DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                    NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                    2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                    TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                                                    3.DAMPERS SHIPPED LOOSE, FIELD
+                                                                                                                                                                                                                                    INSTALLATION REQUIRED.
+
+                                                                                                                           Alternate                                                                    6"
+                                                                                                                           Power Wiring
+                                                                      Alternate                                            Inlet 7/8"                                                                   TYP.
+                                                                      Control Wiring
+                                                                      Inlet 7/8"                                        20 1/8" Minimum                                               FRONT VIEW                  RIGHT VIEW
+                                                                                                                          Service Area
+                                                                               TOP VIEW                                  (Doors can be                                                (OA/RA) DAMPER OPTION (QTY.2)
+                                                                                                                                                                                            (SHIPPED LOOSE)
+                                                                                                                   Removed from Hinges.)
+
+                                                                                                                                                                                                  SCALE 1:16
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 17                     23 3/4"                                                                                               Door-interlocked   2 7/8" Typ.                              12"
+                                                                                         Overall                                                                                                                                    OA Isolation Typ.
+                                                                                                                                                                                               Disconnect Switch  Pressure          Damper
+                                                                      12 7/8"                          Control Wiring                                                                       49 1/8"               Ports (4) Typ.    Wiring Conn.                10 3/8"
+                                                                                                       Inlet 7/8"                                                                            Case
+
+                                                                                                                                                                                  EA                              OA                                            27 1/2"
+                                                                                                                                                                                                                                                                     35 5/8" Overall
+                                                                      27 5/8"                          Power Wiring                                                                                                   34 7/8" Case  RA Isolation
+                                                                            8 7/8" Typ.                Inlet 7/8"                                                                                                                   Damper
+                                                                                                                                                                                                                  RA                Wiring Conn.
+                                                                                                                                       FA
+
+                                                                                                          12"
+                                                                                                       Typ.
+
+                                                                      8 5/8"                                                                                                                Leveling              3/4"-1 7/8" Typ.                                        10 3/8"
+                                                                                                                                                                                            Feet (4)
+                                                                                         LEFT VIEW                                                                                                                                    RIGHT VIEW
+                                                                                                                                                                                            FRONT VIEW
+                                                                                                                                                                                                                                    UNIT MOUNTING & APPLICATION
+                                                                      MAoIRdFeLlO: W HEC1OXNINFIHGURATION                                                                                                                           Can be mounted in any orientation. RA/EA airstream
+                                                                      DAravaiwlabilenags shToywpn ined:imUennsioitn dDraiwminge. nsion                                                                                              can be switched with OA/FA airstream unless
+                                                                      Version: MAY18                                                                                                                                                certain options are selected.
+
+                                                                                                                                                                                                        HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 1XINH                                                                   Energy Recovery Ventilator
+                                                                           Standard with Bypass Economizer
+
+INDOOR UNIT                                                                SPECIFICATIONS                                                     Options:
+                                                                                                                                              Qty. 2, Variable Speed/ECM - Direct Drive Motors
+Download specification at:                                                 Ventilation Type:
+renewaire.com/specifications                                               Static plate, heat and humidity transfer                              (see HE1XINH EC Motor submittal) -
+                                                                                                                                                 0.5 HP, 120V/1Ph/60HZ,
+                                                                           Typical Airflow Range: 250-925 CFM                                     0.5 HP, 208-230V/1Ph/60HZ
+                                                                                                                                              Independent blower control
+                                                                           AHRI 1060 Certified Core: One L125-G5                               Fused disconnect
+                                                                                                                                              Integrated programmable controls -
+                                                                           Standard Features:                                                    enhanced, premium
+                                                                           Non-fused disconnect                                               Bypass economizer damper
+                                                                           24 VAC transformer/relay package                                      (see bypass DIM drawing) -
+                                                                           Cross-core differential pressure ports                                dry-bulb temperature controls (standard),
+                                                                                                                                                 enthalpy controls (option)
+                                                                           Filters:                                                           Low-leakage motorized isolation dampers -
+                                                                           Total qty. 2, MERV 8: 20" x 20" x 2"                                  OA, RA or both airstreams
+                                                                                                                                              Qty. 2, Factory mounted filter alarms -
+                                                                           Unit Dimensions & Weight:                                             both airstreams
+                                                                           54 3/4" L x 23 3/4" W x 35 3/4" H                                  Double wall construction
+                                                                           204-275 lbs., varies by option(s)                                  Exterior paint - white, custom colors
+
+                                                                           Max. Shipping Dimensions & Weight (on pallet):                     Accessories:
+                                                                           63" L x 30" W x 56" H                                              Filters - MERV 13, 2" (shipped loose)
+                                                                           325 lbs.                                                           Backdraft damper 12"
+                                                                           Accessories box shipped loose on top of unit.                      Motorized isolation damper - both airstreams
+                                                                                                                                              Wall cap 12" - galvanized, paintable galvanneal
+                                                                           Motor(s):                                                          Solid state speed control kit - 115V,
+                                                                           Qty. 2, 0.75 HP ea., Direct drive blower/standard
+                                                                                                                                                 208-230V (1 required per motor)
+                                                                              motor packages                                                  Digital time clock - wall mount (TC7D-W),
+
+              Thermal Performance Ratings G5 2015.2.xlsx                                                      HE1X (IOM)                         in exterior enclosure (TC7D-E)
+                                                                                                                                              Carbon dioxide sensor/control -
+
+                                                                                                                                                 wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                              IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                 duct mount (IAQ-D)
+                                                                                                                                              Motion occupancy sensor/control -
+
+                                                                                                                                                 ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                              Smoke Detector - duct mount (SD-D)
+                                                                                                                                              Electric duct heater - RH series (1-11.5 kW);
+
+                                                                                                                                                 EK series (1–175 kW);
+                                                                                                                                                 designed for indoor ductwork installation only
+                                                                                                                                              Indirect gas-fired duct furnace - GH series
+                                                                                                                                                 (50-400 MBH), installed downstream of any fans
+
+AIRFLOW PERFORMANCE
+
+    Motor HP                                                                                  External Static Pressure (Inches Water Column)
+
+    Phase               0.0                                   0.25                            0.5             0.75              0.9              1.25                                         1.5
+
+    0.75        970 CFM                 925 CFM                              860 CFM                            795 CFM           750 CFM     635 CFM                                     480 CFM
+Single Phase  1,490 Watts             1,375 Watts                          1,270 Watts                        1,160 Watts       1,090 Watts   950 Watts                                   825 Watts
+
+    0.75        970 CFM                 925 CFM                              860 CFM                            795 CFM           750 CFM     635 CFM                                     480 CFM
+Three Phase   1,246 Watts             1,158 Watts                          1,039 Watts                          928 Watts         856 Watts   691 Watts                                   509 Watts
+
+Note: Watts is for the entire unit (two motors).
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                            CORE PERFORMANCE
+
+HP  Volts     HZ Phase   FLA   Min.                               Max.                                   Airflow (CFM)
+                         per    Cir.                          Overcurrent
+                        motor  Amps                           Protection   Effectiveness (%)        200  400  600          800  1000
+                                                                                              90%
+                                                                 Device
+
+0.75 120 60 Single 9.0 20.3                                   25
+
+0.75 208-230 60 Single 4.5 10.1                               15                              70%
+
+0.75 277 60 Single 3.9 8.8                                    15                              50%
+
+0.75 208-230 60 Three 1.7-2.3 5.2                             15
+
+0.75 460 60 Three 1.15 2.6                                    15                              30%
+                                                                                                     At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+      Specifications may be subject to change without notice.
+18 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1XINH Energy Recovery Ventilator SWtaitnhdBayrdpawsisthEBcyopnaosms iEzecronOopmtiiozner(Standard & EC Motor)
+
+                                                                                                21 3/4" Case           29"                                                       Bypass                    12" Round Bypass Duct Connection                 ABBREVIATIONS
+                                                                                                                                                                               Damper                      (Direct Mount to Damper, By Others)              EA: Exhaust Air to Outside
+                                                                      Conn. Location                          Door                                                                                                                                          OA: Outside Air Intake
+                                                                             12" Bypass                       Swing                                                                                        BP                                               RA: Room Air to be Exhausted
+                                                                                Damper                                                                                                                                                                      FA: Fresh Air to Inside
+                                                                                                                                        49" Minimum Service Area                    EA                           OA                                         BP: Bypass Air Intake
+                                                                          (Not Shown)                                                      (Doors can be Removed                                                                                            INSTALLATION ORIENTATION
+                                                                      54 3/4" Overall                                                                                               FA                           RA                                         Unit may be installed in any
+                                                                                          7 5/8"                                               from Hinges.)                                                                                                orientation.
+                                                                                                                                                                                                                                       Face Damper          NOTE
+                                                                                                                                                                                                                                                            1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                    BYPASS AIRFLOW SCHEMATIC                                                DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                            NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                        FRONT VIEW                                          2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                            TO CHANGE WITHOUT NOTICE.
+                                                                                                              Door                                                                                                                                          3. UNITS WITH BYPASS WILL REQUIRE
+                                                                                                              Swing                                                                                                                                         ADDITIONAL SPACE FOR THE
+                                                                                                                                                                                                                                                            CONNECTION OF THE BYPASS DUCT
+                                                                                                                                                                               12"                                               9"                         (BY OTHERS).
+                                                                                                                                                                                                                                                            4. FOR INSTALLATION DETAILS, REFER
+                                                                                                                                                                           TYP.                                      TYP.                                   TO I&O MANUAL SUPPLEMENT FOR
+                                                                                                                                                                                                                                                            BYPASS.
+                                                                                                                                          Alternate                                      ISOMETRIC VIEW                                                     5. DAMPERS SHIPPED LOOSE, FIELD
+                                                                                                                                                                                                                                                            INSTALLATION REQUIRED
+                                                                              8 1/8"                                                      Power Wiring                                                     6"
+
+                                                                            Alternate                                                     Inlet 7/8"                                                       TYP.
+                                                                      Control Wiring
+                                                                                                                                        20 1/8" Minimum                    FRONT VIEW                            RIGHT VIEW
+                                                                          Inlet 7/8"                                                    Service Area
+                                                                                                                                        (Doors can be
+                                                                                  TOP VIEW                                              Removed from Hinges.)
+
+                                                                                                                                                                               (OA/RA/BP) DAMPER OPTION (QTY.3)
+                                                                                                                                                                                         (SHIPPED LOOSE)
+                                                                                                                                                                                                  SCALE 1:18
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 19                              23 3/4"                                                         2 7/8"   BP           Door-interlocked
+                                                                                                  Overall                                                            Typ.
+                                                                                                              Control Wiring                                                            Disconnect Switch
+                                                                                                              Inlet 1 1/8"
+                                                                      12 7/8"                                                                                                       49 1/8" Case                 Pressure                           OA Isolation    10 3/8"
+                                                                                                                                                                                                                 Ports (4) Typ.                     Damper
+                                                                                                                                                                                                                                                    Wiring Conn.
+
+                                                                                                                                        EA                                                                       OA
+                                                                                                                                                                                                           3/4" -
+                                                                                                                                                                                                              1 7/8"                                RA
+
+                                                                      27 5/8"                                                                                                                                     Typ.                              Face/Isolation
+                                                                             8 7/8"                                                                                                                                                 34 7/8" Case
+                                                                                                              Power Wiring                                                                                                                                                                          8 7/8"Damper
+                                                                                                              Inlet 7/8"                                                                                                                                                                                 27 1/2"
+                                                                                                                                                                                                                                                    Wiring Conn.
+                                                                                                                                                                                                                                                                                                              38 3/8" Overall
+                                                                                                                                        FA                                                                       RA
+
+                                                                      8 5/8"                                  12" Typ.                  Leveling                                                                                                                      10 3/8"
+                                                                                                                                        Feet (4)
+                                                                                                                                                                                                                                                                    RIGHT VIEW
+                                                                                                  LEFT VIEW                                                                    FRONT VIEW
+
+                                                                      MAIoRdFeLOl: WHEC1OXINNFHIG[UBRypATaIsOsN]                                                                                                                                                  UNIT MOUNTING & APPLICATION
+                                                                      DAvraailawbleinags shToywpn ein :diUmennistioDn dirmaweinng.sion
+                                                                      Version: MAY18                                                                                                                                                                              Can be mounted in any orientation. Airstreams
+                                                                                                                                                                                                                                                                  can not be switched.
+
+                                                                                                                                                                                                          HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 1XINH                                                             EEnneerrggyy RReeccoovveerryy VVeennttiillaattoorr
+                                                                     EECC MMoottoorr wOipthtioBnypass Economizer
+
+INDOOR UNIT                                                          SPECIFICATIONS
+
+Download specification at:                                           Ventilation Type:                                                                                      Options:
+renewaire.com/specifications
+                                                                     Static plate, heat and humidity transfer                                                               Fused disconnect
+EC MOTOR OPTION OPERATING RANGE
+                          HE1XINH EC MOTOR                           Typical Airflow Range: 250-1,100 CFM                                                                    Integrated programmable controls -
+                                                                                                                                                                               enhanced, premium
+                                                                     AHRI 1060 Certified Core: One L125-G5
+                                                                                                                                                                            Bypass economizer damper
+
+                                                                     Standard Features:                                                                                               (see bypass DIM drawing) -
+
+                                                                     Non-fused disconnect                                                                                             dry-bulb temperature controls (standard),
+
+                                                                     24 VAC transformer/relay package                                                                                 enthalpy controls (option)
+
+                                                                     Cross-core differential pressure ports                                                                 Low-leakage motorized isolation dampers -
+
+                                                                     Filters:                                                                                                  OA, RA or both airstreams
+                                                                     Total qty. 2, MERV 8: 20" x 20" x 2"                                                                   Qty. 2, Factory mounted filter alarms -
+
+                                                                                                                                                                               both airstreams
+
+                                                                     Unit Dimensions & Weight:                                                                              Double wall construction
+
+                                                                     54 3/4" L x 23 3/4" W x 35 3/4" H                                                                      Exterior paint - white, custom colors
+
+                                                                     207-278 lbs., varies by option(s)                                                                      Accessories:
+
+                                                                     Max. Shipping Dimensions & Weight (on pallet): Filters - MERV 13, 2" (shipped loose)
+
+                                                                     63" L x 30" W x 56" H                                                                                  Backdraft damper 12"
+
+                                                                     325 lbs.                                                                                               Motorized isolation damper - both airstreams
+
+                                                                     Accessories box shipped loose on top of unit.                                                          Wall cap 12" - galvanized, paintable galvanneal
+
+                                                                     Motor(s):                                                                                              Potentiometer speed control - remote installed
+                                                                     Qty. 2, 0.5 HP ea., Direct drive EC blower/                                                            Digital time clock - wall mount (TC7D-W),
+
+                                                                        motor packages                                                                                         in exterior enclosure (TC7D-E)
+                                                                                                                                                                            Carbon dioxide sensor/control -
+
+                                                                                                                                                                                      wall mount (CO2-W), duct mount (CO2-D)
+
+                                                                                                                                                                            IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                                                      duct mount (IAQ-D)
+
+                                                                                                                                                                            Motion occupancy sensor/control -
+
+                                                                                                                                                                                      ceiling mount (MC-C), wall mount (MC-W)
+
+                                                                                                                                                                            Smoke Detector - duct mount (SD-D)
+
+                                                                                                                                                                            Electric duct heater - RH series (1-11.5 kW);
+
+                                                                                                                                                                                      EK series (1–175 kW);
+
+                                                                                                                                                                                      designed for indoor ductwork installation only
+
+                                                                                                                                                HE1X-IN ECM (HIondriVre)ct gas-fired duct furnace - GH series
+                                                                                                                                                                                      (50-400 MBH), installed downstream of any fans
+
+                                                                                                          1.75
+
+         Sample Points Depicted in Larger Dots
+
+    Airflow      External Static   Unit Power                                                              1.50                                                     992
+    (CFM)          Pressure      Consumption                                                              1.25                                             918
+
+                (Inches Water       (Watts)
+                   Column)
+                                                                                                                                                                                      1029
+
+    324                0.04                             86           External Static Pressure (in. w.g.)                                        655                         911
+
+    446         TThheerrmmaall0PP.0ee7rrffoorrmmaannccee RRaattiinn1gg5ss0GG55 22001155..22..xxllssxx 1.00                             HHEE11XX ((IIOOMM))                                1075
+                                                                                                                                                                                 871
+    647                0.15                             300                                                                                                 643
+
+    794                0.24                             564                                               0.75                                                                                  1068
+
+                                                                                                                                       392                       599                  852
+
+    929                0.33                             827
+
+    1019               0.41                             1042                                                                                    386              583                              1056
+                                                                                                                                                  359               572               839
+                                                                                                                                                      340
+    300                0.11                             91                                                0.50                                                                                         1042
+                                                                                                                                  173
+    406                0.20                             160                                                                                                                                 827
+
+    579                0.42                             359                                               0.25                   164            322                         564                 818     1029 (Watts)
+                                                                                                                       97          160            300                           560
+                                                                                                                                     156
+    713                0.65                             599                                                                89          153           273
+                                                                                                                             85         150
+    828                0.89                             871                                               0.00                            148
+                                                                                                               250                                               750                             1000                 1250
+                                                                                                                                           500
+
+    883                1.00                             1075                                                                                                 Airflow (cfm)
+                                                                                                                     = Actual tested sample points
+Note: Watts is for the entire unit.
+Note: Airflow performance includes effect of clean, standard filter    CORE PERFORMANCE
+supplied with unit.                                                                         AAiirrffllooww ((CCFFMM))
+
+ELECTRICAL DATA                                                      EffEffecetictvievneensess( (%)%)     90%220000        440000      660000   880000                      11000000
+
+                                                            Max.                                          90%
+                                                        Overcurrent
+HP  Volts   HZ  Phase   FLA      Min.                   Protection                                        7700%%
+                        per       Cir.
+                       motor     Amps                      Device
+
+0.5 120 60 Single 8.1 18.2                                   25                                           50%
+                                                                                                          50%
+
+0.5 208-230 60 Single 4.8 10.8                               15                                           3300%% At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+Specifications may be subject to change without notice.
+
+20 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1XINH Energy Recovery Ventilator EC Motor with Bypass Economizer
+
+                                                                                                21 3/4" Case           29"                                                       Bypass                    12" Round Bypass Duct Connection                 ABBREVIATIONS
+                                                                                                                                                                               Damper                      (Direct Mount to Damper, By Others)              EA: Exhaust Air to Outside
+                                                                      Conn. Location                          Door                                                                                                                                          OA: Outside Air Intake
+                                                                             12" Bypass                       Swing                                                                                        BP                                               RA: Room Air to be Exhausted
+                                                                                Damper                                                                                                                                                                      FA: Fresh Air to Inside
+                                                                                                                                        49" Minimum Service Area                    EA                           OA                                         BP: Bypass Air Intake
+                                                                          (Not Shown)                                                      (Doors can be Removed                                                                                            INSTALLATION ORIENTATION
+                                                                      54 3/4" Overall                                                                                               FA                           RA                                         Unit may be installed in any
+                                                                                          7 5/8"                                               from Hinges.)                                                                                                orientation.
+                                                                                                                                                                                                                                       Face Damper          NOTE
+                                                                                                                                                                                                                                                            1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                    BYPASS AIRFLOW SCHEMATIC                                                DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                            NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                        FRONT VIEW                                          2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                            TO CHANGE WITHOUT NOTICE.
+                                                                                                              Door                                                                                                                                          3. UNITS WITH BYPASS WILL REQUIRE
+                                                                                                              Swing                                                                                                                                         ADDITIONAL SPACE FOR THE
+                                                                                                                                                                                                                                                            CONNECTION OF THE BYPASS DUCT
+                                                                                                                                                                               12"                                               9"                         (BY OTHERS).
+                                                                                                                                                                                                                                                            4. FOR INSTALLATION DETAILS, REFER
+                                                                                                                                                                           TYP.                                      TYP.                                   TO I&O MANUAL SUPPLEMENT FOR
+                                                                                                                                                                                                                                                            BYPASS.
+                                                                                                                                          Alternate                                      ISOMETRIC VIEW                                                     5. DAMPERS SHIPPED LOOSE, FIELD
+                                                                                                                                                                                                                                                            INSTALLATION REQUIRED
+                                                                              8 1/8"                                                      Power Wiring                                                     6"
+
+                                                                            Alternate                                                     Inlet 7/8"                                                       TYP.
+                                                                      Control Wiring
+                                                                                                                                        20 1/8" Minimum                    FRONT VIEW                            RIGHT VIEW
+                                                                          Inlet 7/8"                                                    Service Area
+                                                                                                                                        (Doors can be
+                                                                                  TOP VIEW                                              Removed from Hinges.)
+
+                                                                                                                                                                               (OA/RA/BP) DAMPER OPTION (QTY.3)
+                                                                                                                                                                                         (SHIPPED LOOSE)
+                                                                                                                                                                                                  SCALE 1:18
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 21                              23 3/4"                                                         2 7/8"   BP           Door-interlocked
+                                                                                                  Overall                                                            Typ.
+                                                                                                              Control Wiring                                                            Disconnect Switch
+                                                                                                              Inlet 1 1/8"
+                                                                      12 7/8"                                                                                                       49 1/8" Case                 Pressure                           OA Isolation    10 3/8"
+                                                                                                                                                                                                                 Ports (4) Typ.                     Damper
+                                                                                                                                                                                                                                                    Wiring Conn.
+
+                                                                                                                                        EA                                                                       OA
+                                                                                                                                                                                                           3/4" -
+                                                                                                                                                                                                              1 7/8"                                RA
+
+                                                                      27 5/8"                                                                                                                                     Typ.                              Face/Isolation
+                                                                             8 7/8"                                                                                                                                                 34 7/8" Case
+                                                                                                              Power Wiring                                                                                                                                                                          8 7/8"Damper
+                                                                                                              Inlet 7/8"                                                                                                                                                                                 27 1/2"
+                                                                                                                                                                                                                                                    Wiring Conn.
+                                                                                                                                                                                                                                                                                                              38 3/8" Overall
+                                                                                                                                        FA                                                                       RA
+
+                                                                      8 5/8"                                  12" Typ.                  Leveling                                                                                                                      10 3/8"
+                                                                                                                                        Feet (4)
+                                                                                                                                                                                                                                                                    RIGHT VIEW
+                                                                                                  LEFT VIEW                                                                    FRONT VIEW
+
+                                                                      MAIoRdFeLOl: WHEC1OXINNFHIG[UBRypATaIsOsN]                                                                                                                                                  UNIT MOUNTING & APPLICATION
+                                                                      DAvraailawbleinags shToywpn ein :diUmennistioDn dirmaweinng.sion
+                                                                      Version: MAY18                                                                                                                                                                              Can be mounted in any orientation. Airstreams
+                                                                                                                                                                                                                                                                  can not be switched.
+
+                                                                                                                                                                                                          HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 1XINV                                                                   Energy Recovery Ventilator
+                                                                           Standarrdd & Bypass Economizer Option
+
+INDOOR UNIT                                                                SPECIFICATIONS                                                     Options:
+                                                                                                                                              Qty. 2, Variable Speed/ECM - Direct Drive Motors
+Download specification at:                                                 Ventilation Type:
+renewaire.com/specifications                                               Static plate, heat and humidity transfer                              (see HE1XINV EC Motor submittal) -
+                                                                                                                                                 0.5 HP 120V/1Ph/60HZ,
+                                                                           Typical Airflow Range: 250-925 CFM                                     0.5 HP 208-230V/1Ph/60HZ
+                                                                                                                                              Independent blower control
+                                                                           AHRI 1060 Certified Core: One L125-G5                               Fused disconnect
+                                                                                                                                              Integrated programmable controls -
+                                                                           Standard Features:                                                    enhanced, premium
+                                                                           Non-fused disconnect                                               Bypass economizer damper
+                                                                           24 VAC transformer/relay package                                      (see bypass DIM drawing) -
+                                                                           Cross-core differential pressure ports                                dry-bulb temperature controls (standard),
+                                                                                                                                                 enthalpy controls (option)
+                                                                           Filters:                                                           Low-leakage motorized isolation dampers -
+                                                                           Total qty. 2, MERV 8: 20" x 20" x 2"                                  OA, RA or both airstreams
+                                                                                                                                              Qty. 2, Factory mounted filter alarms -
+                                                                           Unit Dimensions & Weight:                                             both airstreams
+                                                                           40 1/2" L x 23 3/4" W x 50 3/4" H                                  Double wall construction
+                                                                           201-272 lbs., varies by option(s)                                  Exterior paint - white, custom colors
+
+                                                                           Max. Shipping Dimensions & Weight (on pallet):                     Accessories:
+                                                                           30" L x 42" W x 71" H                                              Filters - MERV 13, 2" (shipped loose)
+                                                                           325 lbs.                                                           Backdraft damper 12"
+                                                                           Accessories box shipped loose on top of unit.                      Motorized isolation damper - both airstreams
+                                                                                                                                              Wall cap 12" - galvanized, paintable galvanneal
+                                                                           Motor(s):                                                          Solid state speed control kit - 115V,
+                                                                           Qty. 2, 0.75 HP ea., Direct drive blower/standard
+                                                                                                                                                 208-230V (1 required per motor)
+                                                                              motor packages                                                  Digital time clock - wall mount (TC7D-W),
+
+              Thermal Performance Ratings G5 2015.2.xlsx                                                      HE1X (IOM)                         in exterior enclosure (TC7D-E)
+                                                                                                                                              Carbon dioxide sensor/control -
+
+                                                                                                                                                 wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                              IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                 duct mount (IAQ-D)
+                                                                                                                                              Motion occupancy sensor/control -
+
+                                                                                                                                                 ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                              Smoke Detector - duct mount (SD-D)
+                                                                                                                                              Electric duct heater - RH series (1-11.5 kW);
+
+                                                                                                                                                 EK series (1–175 kW);
+                                                                                                                                                 designed for indoor ductwork installation only
+                                                                                                                                              Indirect gas-fired duct furnace - GH series
+                                                                                                                                                 (50-400 MBH), installed downstream of any fans
+
+AIRFLOW PERFORMANCE
+
+Motor HP                                                                                      External Static Pressure (Inches Water Column)
+
+Phase         0.0                                             0.25                            0.5             0.75              0.9              1.25                                         1.5
+
+    0.75        970 CFM                             925 CFM                  860 CFM                            795 CFM           750 CFM     635 CFM                                     480 CFM
+Single Phase  1,490 Watts                         1,375 Watts              1,270 Watts                        1,160 Watts       1,090 Watts   950 Watts                                   825 Watts
+
+    0.75        970 CFM                             925 CFM                  860 CFM                            795 CFM           750 CFM     635 CFM                                     480 CFM
+Three Phase   1,246 Watts                         1,158 Watts              1,039 Watts                          928 Watts         856 Watts   691 Watts                                   509 Watts
+
+Note: Watts is for the entire unit (2 motors).
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                            CORE PERFORMANCE
+
+                                       FLA Min.                   Max.                                   Airflow (CFM)
+  HP Volts HZ Phase per Cir.                                  Overcurrent
+                                                              Protection   Effectiveness (%)        200  400  600          800  1000
+                                      motor Amps                                              90%
+                                                                 Device
+ 0.75 120 60 Single 9.0 20.3                                       25                         70%
+ 0.75 208-230 60 Single 4.5 10.1
+ 0.75 277 60 Single 3.9 8.8                                        15                         50%
+ 0.75 208-230 60 Three 1.7-2.3 5.2
+ 0.75 460 60 Three 1.15 2.6                                        15                         30%
+                                                                                                     At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+                                                                   15
+
+                                                                   15
+
+      Specifications may be subject to change without notice.
+22 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1XINV Energy Recovery Ventilator Standaarrdd or EC Motor Option                                                                                                                                                     ABBREVIATIONS
+                                                                                                                                                                                                                                                                                            EA: Exhaust Air to Outside
+                                                                                                                       23 3/4"                                                                                                                                                              OA: Outside Air Intake
+                                                                                                                       Overall                                                                                                                                                              RA: Room Air to be Exhausted
+                                                                                                                                                                                                                                                                                            FA: Fresh Air to Inside
+                                                                                       40 3/8" Overall                                                                              12"                                            9"                                                       INSTALLATION ORIENTATION
+                                                                                                                                                                                                                                                                                            Unit may be installed in any
+                                                                                                                                                                                    TYP.            ISOMETRIC VIEW               TYP.                                                       orientation.
+                                                                                                                                                                                                                                                                                            NOTE
+                                                                                                                                                                                                                        6"                                                                  1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                       TYP.                                                                 DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                                                            NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                                                            2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                                                            TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                                                                                                            3. DAMPERS SHIPPED LOOSE, FIELD
+                                                                                                                                                                                                                                                                                            INSTALLATION REQUIRED
+
+                                                                                                                                                                                    FRONT VIEW                         RIGHT VIEW17 3/4"
+                                                                                                                                                                                                                                                          49" Minimum
+                                                                                                        TOP VIEW                                                                    (OA/RA) DAMPER OPTION (QTY. 2)                                            Service Area                              20 1/8" Minimum
+                                                                                                                                                                                                (SHIPPED LOOSE)                                                   (Doors can be                           Service Area
+                                                                                                                                                                                                     SCALE 1:16                                                      Removed from Hinges.)               (Doors can be
+
+                                                                                                                                                                                                                                                                                                         Removed from
+                                                                                                                                                                                                                                                                                                              Hinges.)
+
+                                                                      10 3/8" Typ.                                12" Typ.                                                                Pressure  34 7/8" Case                 2 7/8" Typ.                                                29"         21 3/4"
+                                                                                                                                                                                    Ports (4) Typ.
+                                                                                                                        RA Isolation                                                                                                 OA                                                                 Case
+                                                                                                                        Damper                                                           RA
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 23                                                    Wiring Conn.                                                                                                                                                             Door
+                                                                                                                                                                                                                                                                                                 Swing
+
+                                                                      50 3/4" Overall                             40 3/4" Typ.                                        49 1/8" Case        FA                                     EA                                                              Door
+                                                                                                                       49 7/8" Typ.                                                                                                                                                              Swing
+
+                                                                                       16 1/4"
+                                                                                          Typ.
+
+                                                                                                                  12 7/8"                                                                                                                     OA Isolation                                                               8 5/8"
+                                                                                     Power and                                                                                                                                                Damper
+                                                                                Control Wiring                                                                        3/4" - 1 7/8" Typ.            Door-Interlocked                          Wiring Conn.
+                                                                                    Inlets 7/8"                                                                                                     Disconnect Switch
+                                                                                                                                                                                                                       Leveling
+                                                                                      LEFT VIEW                                                                                                                        Feet (4)
+
+                                                                      DMAAvIarRoialaFdbwLleeOainslW:sghHoCwTEOny1iNnpXdFeIimNIG:eVnUUsiRonnAidtTraDIwOiinNmg. ension                                FRONT VIEW                                                                                     RIGHT VIEW
+                                                                      Version: MAY18
+                                                                                                                                                                                                                                                                                            UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                                                                                                                            Can be mounted in any orientation. RA/EA airstream
+                                                                                                                                                                                                                                                                                            can be switched with OA/FA airstream unless
+                                                                                                                                                                                                                                                                                            certain options are selected.
+
+                                                                                                                                                                                                                       HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 1XINV                                                             Energy Recovery Ventilator
+                                                                     EC Motor Option
+
+INDOOR UNIT                                                          SPECIFICATIONS
+
+Download specification at:                                           Ventilation Type:                                                                                      Options:
+renewaire.com/specifications
+EC MOTOR OPTION OPERATING RANGE                                      Static plate, heat and humidity transfer                                                               Fused disconnect
+
+                                                                     Typical Airflow Range: 250-1,100 CFM                                                                    Integrated programmable controls -
+                                                                                                                                                                               enhanced, premium
+
+                                                                     AHRI 1060 Certified Core: One L125-G5                                                                   Bypass economizer damper
+
+                                                                     Standard Features:                                                                                        (see bypass DIM drawing) -
+                                                                     Non-fused disconnect                                                                                      dry-bulb temperature controls (standard),
+                                                                     24 VAC transformer/relay package                                                                          enthalpy controls (option)
+                                                                     Cross-core differential pressure ports                                                                 Low-leakage motorized isolation dampers -
+                                                                                                                                                                               OA, RA or both airstreams
+                                                                     Filters:                                                                                               Qty. 2, Factory mounted filter alarms -
+                                                                     Total qty. 2, MERV 8: 20" x 20" x 2"                                                                      both airstreams
+
+                                                                     Unit Dimensions & Weight:                                                                              Double wall construction
+                                                                     40 1/2" L x 23 3/4" W x 50 3/4" H                                                                      Exterior paint - white, custom colors
+
+                                                                     204-275 lbs., varies by option(s)                                                                      Accessories:
+
+                                                                     Shipping Dimensions & Weight (on pallet):                                                              Filters - MERV 13, 2" (shipped loose)
+                                                                     30" L x 42" W x 71" H                                                                                  Backdraft damper 12"
+                                                                     325 lbs.                                                                                               Motorized isolation damper - both airstreams
+                                                                     Accessories box shipped loose on top of unit.                                                          Wall cap 12" - galvanized, paintable galvanneal
+                                                                                                                                                                            Potentiometer speed control - remote installed
+                                                                     Motor(s):                                                                                              Digital time clock - wall mount (TC7D-W),
+                                                                     Qty. 2, 0.5 HP ea., Direct drive EC blower/
+                                                                                                                                                                               in exterior enclosure (TC7D-E)
+                                                                        motor packages                                                                                      Carbon dioxide sensor/control -
+
+                                                                                                                                                                                    wall mount (CO2-W), duct mount (CO2-D)
+
+                                                                                                                                                                            IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                                                    duct mount (IAQ-D)
+
+                                                                                                                                                                            Motion occupancy sensor/control -
+
+                                                                                                                                                                                    ceiling mount (MC-C), wall mount (MC-W)
+
+                                                                                                                                                                            Smoke Detector - duct mount (SD-D)
+
+                                                                                                                                                                            Electric duct heater - RH series (1-11.5 kW);
+
+                                                                                                                                                                                    EK series (1–175 kW);
+
+                                                                                                                                                                                    designed for indoor ductwork installation only
+
+                                                                                                                                                HE1X-IN ECM (InHdoi(r5er0cV-t4)g0a0s-MfirBeHd)d, uincsttfaullrendacdeow- nGsHtrseearmiesof any fans
+
+                HE1XINV EC MOTOR                                                                          1.75
+
+         Sample Points Depicted in Larger Dots
+
+    Airflow      External Static    Unit Power                                                             1.50                                                                 992
+    (CFM)          Pressure       Consumption                                                             1.25                                                         918
+
+                (Inches Water        (Watts)
+                   Column)
+                                                                                                                                                                                    1029
+
+    324                0.04                             86           External Static Pressure (in. w.g.)                                        655                         911
+
+    446         Thermal0P.0e7rformance Ratin1g5s0G5 2015.2.xlsx                                           1.00                         HE1X (IOM)                                            1075
+                Thermal Performance Ratings G5 2015.2.xlsx                                                                             HE1X (IOM)                                   871
+    647                0.15                             300
+                                                                                                                                                            643
+
+    794                0.24                             564                                                                                                                                        1068
+
+    929                0.33                             827                                               0.75                         392                             599                   852
+
+    1019               0.41                             1042                                                                                    386                    583                               1056
+                                                                                                                                                  359                     572                839
+                                                                                                                                                      340
+    300                0.11                             91                                                0.50                                                                                               1042
+                                                                                                                                  173
+    406                0.20                             160                                                                                                                                       827
+
+    579                0.42                             359                                               0.25                   164            322                                 564            818         1029 (Watts)
+                                                                                                                       97          160            300                                   560
+                                                                                                                                     156
+    713                0.65                             599                                                                89          153           273
+                                                                                                                             85         150
+    828                0.89                             871                                               0.00                            148
+                                                                                                               250
+                                                                                                                                           500                         750                             1000                  1250
+
+    883                1.00                             1075                                                                                    Airflow (cfm)
+
+                                                                                                                = Actual tested sample points
+
+Note: Watts is for the entire unit.                                  CORE PERFORMANCE
+Note: Airflow performance includes effect of clean, standard filter
+supplied with unit.                                                                                                                    AAiirrffllooww ((CCFFMM))
+
+                                                                     EffEfefcetictvievneensess (s (%)%)         200        400         600                        800       1000
+ELECTRICAL DATA                                                                                           90%200           400         600                        800       1000
+
+                                                            Max.                                          90%
+                                                        Overcurrent
+HP  Volts   HZ  Phase   FLA      Min.                   Protection                                        70%
+                        per       Cir.                                                                    70%
+                       motor     Amps                      Device
+
+0.5 120 60 Single 8.1 18.2                                   25                                           50%
+                                                                                                          50%
+
+0.5 208-230 60 Single 4.8 10.8                               15                                           30%
+                                                                                                          30% At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+Specifications may be subject to change without notice.
+
+24 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1XINV Energy Recovery Ventilator SEtCanMdoatrodr oOrpEtiConMotor Option                                                                                                                                             ABBREVIATIONS
+                                                                                                                                                                                                                                                                                            EA: Exhaust Air to Outside
+                                                                                                                       23 3/4"                                                                                                                                                              OA: Outside Air Intake
+                                                                                                                       Overall                                                                                                                                                              RA: Room Air to be Exhausted
+                                                                                                                                                                                                                                                                                            FA: Fresh Air to Inside
+                                                                                       40 3/8" Overall                                                                              12"                                            9"                                                       INSTALLATION ORIENTATION
+                                                                                                                                                                                                                                                                                            Unit may be installed in any
+                                                                                                                                                                                    TYP.            ISOMETRIC VIEW               TYP.                                                       orientation.
+                                                                                                                                                                                                                                                                                            NOTE
+                                                                                                                                                                                                                        6"                                                                  1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                       TYP.                                                                 DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                                                            NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                                                            2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                                                            TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                                                                                                            3. DAMPERS SHIPPED LOOSE, FIELD
+                                                                                                                                                                                                                                                                                            INSTALLATION REQUIRED
+
+                                                                                                                                                                                    FRONT VIEW                         RIGHT VIEW17 3/4"
+                                                                                                                                                                                                                                                          49" Minimum
+                                                                                                        TOP VIEW                                                                    (OA/RA) DAMPER OPTION (QTY. 2)                                            Service Area                              20 1/8" Minimum
+                                                                                                                                                                                                (SHIPPED LOOSE)                                                   (Doors can be                           Service Area
+                                                                                                                                                                                                     SCALE 1:16                                                      Removed from Hinges.)               (Doors can be
+
+                                                                                                                                                                                                                                                                                                         Removed from
+                                                                                                                                                                                                                                                                                                              Hinges.)
+
+                                                                      10 3/8" Typ.                                12" Typ.                                                                Pressure  34 7/8" Case                 2 7/8" Typ.                                                29"         21 3/4"
+                                                                                                                                                                                    Ports (4) Typ.
+                                                                                                                        RA Isolation                                                                                                 OA                                                                 Case
+                                                                                                                        Damper                                                           RA
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 25                                                    Wiring Conn.                                                                                                                                                             Door
+                                                                                                                                                                                                                                                                                                 Swing
+
+                                                                      50 3/4" Overall                             40 3/4" Typ.                                        49 1/8" Case        FA                                     EA                                                              Door
+                                                                                                                       49 7/8" Typ.                                                                                                                                                              Swing
+
+                                                                                       16 1/4"
+                                                                                          Typ.
+
+                                                                                                                  12 7/8"                                                                                                                     OA Isolation                                                               8 5/8"
+                                                                                     Power and                                                                                                                                                Damper
+                                                                                Control Wiring                                                                        3/4" - 1 7/8" Typ.            Door-Interlocked                          Wiring Conn.
+                                                                                    Inlets 7/8"                                                                                                     Disconnect Switch
+                                                                                                                                                                                                                       Leveling
+                                                                                      LEFT VIEW                                                                                                                        Feet (4)
+
+                                                                      DMAAvIarRoialaFdbwLleeOainslW:sghHoCwTEOny1iNnpXdFeIimNIG:eVnUUsiRonnAidtTraDIwOiinNmg. ension                                FRONT VIEW                                                                                     RIGHT VIEW
+                                                                      Version: MAY18
+                                                                                                                                                                                                                                                                                            UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                                                                                                                            Can be mounted in any orientation. RA/EA airstream
+                                                                                                                                                                                                                                                                                            can be switched with OA/FA airstream unless
+                                                                                                                                                                                                                                                                                            certain options are selected.
+
+                                                                                                                                                                                                                       HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 1XINV                                                                   Energy Recovery Ventilator
+                                                                           Standard with Bypass Economizer
+
+INDOOR UNIT                                                                SPECIFICATIONS                                                     Options:
+                                                                                                                                              Qty. 2, Variable Speed/ECM - Direct Drive Motors
+Download specification at:                                                 Ventilation Type:
+renewaire.com/specifications                                               Static plate, heat and humidity transfer                              (see HE1XINV EC Motor submittal) -
+                                                                                                                                                 0.5 HP 120V/1Ph/60HZ,
+                                                                           Typical Airflow Range: 250-925 CFM                                     0.5 HP 208-230V/1Ph/60HZ
+                                                                                                                                              Independent blower control
+                                                                           AHRI 1060 Certified Core: One L125-G5                               Fused disconnect
+                                                                                                                                              Integrated programmable controls -
+                                                                           Standard Features:                                                    enhanced, premium
+                                                                           Non-fused disconnect                                               Bypass economizer damper
+                                                                           24 VAC transformer/relay package                                      (see bypass DIM drawing) -
+                                                                           Cross-core differential pressure ports                                dry-bulb temperature controls (standard),
+                                                                                                                                                 enthalpy controls (option)
+                                                                           Filters:                                                           Low-leakage motorized isolation dampers -
+                                                                           Total qty. 2, MERV 8: 20" x 20" x 2"                                  OA, RA or both airstreams
+                                                                                                                                              Qty. 2, Factory mounted filter alarms -
+                                                                           Unit Dimensions & Weight:                                             both airstreams
+                                                                           40 1/2" L x 23 3/4" W x 50 3/4" H                                  Double wall construction
+                                                                           201-272 lbs., varies by option(s)                                  Exterior paint - white, custom colors
+
+                                                                           Max. Shipping Dimensions & Weight (on pallet):                     Accessories:
+                                                                           30" L x 42" W x 71" H                                              Filters - MERV 13, 2" (shipped loose)
+                                                                           325 lbs.                                                           Backdraft damper 12"
+                                                                           Accessories box shipped loose on top of unit.                      Motorized isolation damper - both airstreams
+                                                                                                                                              Wall cap 12" - galvanized, paintable galvanneal
+                                                                           Motor(s):                                                          Solid state speed control kit - 115V,
+                                                                           Qty. 2, 0.75 HP ea., Direct drive blower/standard
+                                                                                                                                                 208-230V (1 required per motor)
+                                                                              motor packages                                                  Digital time clock - wall mount (TC7D-W),
+
+              Thermal Performance Ratings G5 2015.2.xlsx                                                      HE1X (IOM)                         in exterior enclosure (TC7D-E)
+                                                                                                                                              Carbon dioxide sensor/control -
+
+                                                                                                                                                 wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                              IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                 duct mount (IAQ-D)
+                                                                                                                                              Motion occupancy sensor/control -
+
+                                                                                                                                                 ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                              Smoke Detector - duct mount (SD-D)
+                                                                                                                                              Electric duct heater - RH series (1-11.5 kW);
+
+                                                                                                                                                 EK series (1–175 kW);
+                                                                                                                                                 designed for indoor ductwork installation only
+                                                                                                                                              Indirect gas-fired duct furnace - GH series
+                                                                                                                                                 (50-400 MBH), installed downstream of any fans
+
+AIRFLOW PERFORMANCE
+
+Motor HP                                                                                      External Static Pressure (Inches Water Column)
+
+Phase         0.0                                             0.25                            0.5             0.75              0.9              1.25                                         1.5
+
+    0.75        970 CFM                             925 CFM                  860 CFM                            795 CFM           750 CFM     635 CFM                                     480 CFM
+Single Phase  1,490 Watts                         1,375 Watts              1,270 Watts                        1,160 Watts       1,090 Watts   950 Watts                                   825 Watts
+
+    0.75        970 CFM                             925 CFM                  860 CFM                            795 CFM           750 CFM     635 CFM                                     480 CFM
+Three Phase   1,246 Watts                         1,158 Watts              1,039 Watts                          928 Watts         856 Watts   691 Watts                                   509 Watts
+
+Note: Watts is for the entire unit (2 motors).
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                            CORE PERFORMANCE
+
+                                       FLA Min.                   Max.                                   Airflow (CFM)
+  HP Volts HZ Phase per Cir.                                  Overcurrent
+                                                              Protection   Effectiveness (%)        200  400  600          800  1000
+                                      motor Amps                                              90%
+                                                                 Device
+ 0.75 120 60 Single 9.0 20.3                                       25                         70%
+ 0.75 208-230 60 Single 4.5 10.1
+ 0.75 277 60 Single 3.9 8.8                                        15                         50%
+ 0.75 208-230 60 Three 1.7-2.3 5.2
+ 0.75 460 60 Three 1.15 2.6                                        15                         30%
+                                                                                                     At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+                                                                   15
+
+                                                                   15
+
+      Specifications may be subject to change without notice.
+26 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1XINV Energy Recovery Ventilator SWtaitnhdBayrdpawsisthEBcyopnaosms iEzecronOopmtiiozner(Standard & EC Motor)
+
+                                                                                       26 1/2" Overall                                                                                                                    ABBREVIATIONS
+                                                                                                                                                                                                                          EA: Exhaust Air to Outside
+                                                                                                                                                                            12" Round Bypass Duct Connection              OA: Outside Air Intake
+                                                                                                                                                                           (Direct Mount to Damper, By Others)            RA: Room Air to be Exhausted
+                                                                                                                                                                                                                          FA: Fresh Air to Inside
+                                                                      40 3/8" Overall                     12"                        ISOMETRIC VIEW          9"                                      BP                   BP: Bypass Air Intake
+                                                                           27 5/8"                      TYP.                                                                                                              INSTALLATION ORIENTATION
+                                                                                                                                                             TYP.                                               Bypass    Unit may be installed in any
+                                                                                                                                                                                     Face                       Damper    orientation.
+                                                                                                                                                                                                                          NOTE
+                                                                                                                                                                           Damper                                     EA  1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                          DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                           RA                             NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                          2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                       6"                                                                 TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                                          3. UNITS WITH BYPASS WILL REQUIRE
+                                                                                                                                                       TYP.                          BYPASS AIRFLOW SCHEMATIC             ADDITIONAL SPACE FOR THE
+                                                                                                                                                                                                                          CONNECTION OF THE BYPASS DUCT
+                                                                                   TOP VIEW             FRONT VIEW                                           RIGHT VIEW                                 TOP VIEW          (BY OTHERS).
+                                                                                                                                                                                         (OA/FA Airstream Not Shown)      4. FOR INSTALLATION DETAILS, REFER
+                                                                           10 3/8" Typ.                 (OA/RA/BP) DAMPER OPTION (QTY.3)                                                                                  TO I&O MANUAL SUPPLEMENT FOR
+                                                                                                                                     (SHIPPED LOOSE)                                                                      BYPASS.
+                                                                      RA                                                             SCALE 1:18                                                                           5. DAMPERS SHIPPED LOOSE, FIELD
+                                                                      Face/Isolation                                                                                                                                      INSTALLATION REQUIRED
+                                                                      Damper
+                                                                      Wiring Conn.                      12" Typ.                           Pressure          34 7/8" Case            Bypass              20 1/8" Minimum  29"         21 3/4" Case
+                                                                                                                                     Ports (4) Typ.                                  Location            Service Area
+                                                                         BP                                                                                                                              (Doors can be
+                                                                                                                                                                                             2 7/8"      Removed from
+                                                                                                                                                                                             Typ.        Hinges.)
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 27                                                                               RA                                          OA        49" Minimum Service AreaDoor
+                                                                                                                                                                                                            (Doors can be RemovedSwing
+
+                                                                                                        16 1/4" Typ.                 49 1/8" Case  FA                                          EA               from Hinges.)Door
+                                                                                                             40 3/4" Typ.                                                                                                                                                           9 3/4"Swing
+                                                                                                                  50 3/4" Overall
+                                                                      Conn. Location
+                                                                         12" Bypass      12 7/8"        Power and                    3/4" -              Door-Interlocked  Leveling                             OA Isolation          8 5/8"
+                                                                                                        Control Wiring                  1 7/8"         Disconnect Switch   Feet (4)                             Damper
+                                                                      Damper           LEFT VIEW        Inlets 7/8"                                                                                             Wiring Conn.
+                                                                      (Not Shown)                                                           Typ.
+
+                                                                                                                                                             FRONT VIEW                                                        RIGHT VIEW
+
+                                                                      MAoIRdFLeOl:WHEC1OXNIFNIGVU[RBAyTpIOaNss]                                                                                                                UNIT MOUNTING & APPLICATION
+                                                                      DArvaailawbleinasgshoTwynpinedi:mUensniointdDrawiminge. nsion
+                                                                      Version: MAY18                                                                                                                                           Can be mounted in any orientation. Airstreams
+                                                                                                                                                                                                                               can not be switched.
+
+                                                                                                                                                                                     HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 1XINV                                                             Energy Recovery Ventilator
+                                                                     EC Motoorr wOipthtioBnypass Economizer
+
+INDOOR UNIT                                                          SPECIFICATIONS
+
+                                                                     Ventilation Type:                                                                                              Options:
+
+                                                                     Static plate, heat and humidity transfer                                                                       Fused disconnect
+
+                                                                     Typical Airflow Range: 250-1,100 CFM                                                                            Integrated programmable controls -
+                                                                                                                                                                                       enhanced, premium
+
+                                                                     AHRI 1060 Certified Core: One L125-G5                                                                           Bypass economizer damper
+
+                                                                     Standard Features:                                                                                                (see bypass DIM drawing) -
+                                                                     Non-fused disconnect                                                                                              dry-bulb temperature controls (standard),
+                                                                     24 VAC transformer/relay package                                                                                  enthalpy controls (option)
+                                                                     Cross-core differential pressure ports                                                                         Low-leakage motorized isolation dampers -
+                                                                                                                                                                                       OA, RA or both airstreams
+                                                                     Filters:                                                                                                       Qty. 2, Factory mounted filter alarms -
+                                                                     Total qty. 2, MERV 8: 20" x 20" x 2"                                                                              both airstreams
+
+                                                                     Unit Dimensions & Weight:                                                                                      Double wall construction
+                                                                     40 1/2" L x 23 3/4" W x 50 3/4" H                                                                              Exterior paint - white, custom colors
+
+                                                                     204-275 lbs., varies by option(s)                                                                              Accessories:
+
+                                                                     Shipping Dimensions & Weight (on pallet):                                                                      Filters - MERV 13, 2" (shipped loose)
+                                                                     30" L x 42" W x 71" H                                                                                          Backdraft damper 12"
+                                                                     325 lbs.                                                                                                       Motorized isolation damper - both airstreams
+                                                                     Accessories box shipped loose on top of unit.                                                                  Wall cap 12" - galvanized, paintable galvanneal
+                                                                                                                                                                                    Potentiometer speed control - remote installed
+                                                                     Motor(s):                                                                                                      Digital time clock - wall mount (TC7D-W),
+                                                                     Qty. 2, 0.5 HP ea., Direct drive EC blower/
+                                                                                                                                                                                       in exterior enclosure (TC7D-E)
+                                                                        motor packages                                                                                              Carbon dioxide sensor/control -
+
+Download specification at:                                                                                                                                                          wall mount (CO2-W), duct mount (CO2-D)
+renewaire.com/specifications
+                                                                                                                                                                                    IAQ sensor - wall mount (IAQ-W),
+EC MOTOR OPTION OPERATING RANGE
+                          HE1XINV EC MOTOR                                                                                                                                          duct mount (IAQ-D)
+
+                                                                                                                                                                                    Motion occupancy sensor/control -
+
+                                                                                                                                                                                    ceiling mount (MC-C), wall mount (MC-W)
+
+                                                                                                                                                                                    Smoke Detector - duct mount (SD-D)
+
+                                                                                                                                                                                    Electric duct heater - RH series (1-11.5 kW);
+
+                                                                                                                                                                                    EK series (1–175 kW);
+
+                                                                                                                                                                                    designed for indoor ductwork installation only
+
+                                                                                                                                                                   Indirect gas-fired duct furnace - GH series
+                                                                                                                                                HE1X-IN ECM (H or(5V0) -400 MBH), installed downstream of any fans
+
+                                                                                                          1.75
+
+         Sample Points Depicted in Larger Dots
+
+    Airflow      External Static   Unit Power                                                              1.50                                                                 992
+    (CFM)          Pressure      Consumption                                                              1.25                                                         918
+
+                (Inches Water       (Watts)
+                   Column)
+                                                                                                                                                                                    1029
+
+    324                0.04                             86           External Static Pressure (in. w.g.)                                        655                         911
+
+    446         TThheerrmmaall0PP.0ee7rrffoorrmmaannccee RRaattiinn1gg5ss0GG55 22001155..22..xxllssxx 1.00                             HHEE11XX ((IIOOMM))                                   1075
+                                                                                                                                                                                    871
+    647                0.15                             300                                                                                                 643
+
+    794                0.24                             564                                                                                                                                        1068
+
+                                                                                                          0.75                         392                             599                   852
+
+    929                0.33                             827
+
+    1019               0.41                             1042                                                                                    386                    583                               1056
+                                                                                                                                                  359                     572                839
+                                                                                                                                                      340
+    300                0.11                             91                                                0.50                                                                                               1042
+                                                                                                                                  173
+    406                0.20                             160                                                                                                                                       827
+
+    579                0.42                             359                                               0.25                   164            322                                 564            818         1029 (Watts)
+                                                                                                                       97          160            300                                   560
+                                                                                                                                     156
+    713                0.65                             599                                                                89          153           273
+                                                                                                                             85         150
+    828                0.89                             871                                               0.00                            148
+                                                                                                               250                                                     750                             1000                  1250
+                                                                                                                                           500
+
+    883                1.00                             1075                                                                                    Airflow (cfm)
+
+Note: Watts is for the entire unit.                                                                             = Actual tested sample points
+Note: Airflow performance includes effect of clean, standard filter
+supplied with unit.                                                  CORE PERFORMANCE
+
+                                                                                                                                       AAiirrffllooww ((CCFFMM))
+
+ELECTRICAL DATA                                                      EffEfefcetictvievneenses (s (%)%)          200        400         600                        800       1000
+                                                                                                          90%200           400         600                        800       1000
+
+                                                            Max.                                          90%
+                                                        Overcurrent
+HP  Volts   HZ  Phase   FLA      Min.                   Protection                                        70%
+                        per       Cir.                                                                    70%
+                       motor     Amps                      Device
+
+0.5 120 60 Single 8.1 18.2                                   25                                           50%
+                                                                                                          50%
+
+0.5 208-230 60 Single 4.8 10.8                               15                                           30%
+                                                                                                          30% At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+Specifications may be subject to change without notice.
+
+28 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1XINV Energy Recovery Ventilator W ECithMBotyoprawssithEcBoynpoasmsizEecroOnopmtioizne(rStandard & EC Motor)
+
+                                                                                       26 1/2" Overall                                                                                                                    ABBREVIATIONS
+                                                                                                                                                                                                                          EA: Exhaust Air to Outside
+                                                                                                                                                                            12" Round Bypass Duct Connection              OA: Outside Air Intake
+                                                                                                                                                                           (Direct Mount to Damper, By Others)            RA: Room Air to be Exhausted
+                                                                                                                                                                                                                          FA: Fresh Air to Inside
+                                                                      40 3/8" Overall                     12"                        ISOMETRIC VIEW          9"                                      BP                   BP: Bypass Air Intake
+                                                                           27 5/8"                      TYP.                                                                                                              INSTALLATION ORIENTATION
+                                                                                                                                                             TYP.                                               Bypass    Unit may be installed in any
+                                                                                                                                                                                     Face                       Damper    orientation.
+                                                                                                                                                                                                                          NOTE
+                                                                                                                                                                           Damper                                     EA  1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                          DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                           RA                             NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                          2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                       6"                                                                 TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                                          3. UNITS WITH BYPASS WILL REQUIRE
+                                                                                                                                                       TYP.                          BYPASS AIRFLOW SCHEMATIC             ADDITIONAL SPACE FOR THE
+                                                                                                                                                                                                                          CONNECTION OF THE BYPASS DUCT
+                                                                                   TOP VIEW             FRONT VIEW                                           RIGHT VIEW                                 TOP VIEW          (BY OTHERS).
+                                                                                                                                                                                         (OA/FA Airstream Not Shown)      4. FOR INSTALLATION DETAILS, REFER
+                                                                           10 3/8" Typ.                 (OA/RA/BP) DAMPER OPTION (QTY.3)                                                                                  TO I&O MANUAL SUPPLEMENT FOR
+                                                                                                                                     (SHIPPED LOOSE)                                                                      BYPASS.
+                                                                      RA                                                             SCALE 1:18                                                                           5. DAMPERS SHIPPED LOOSE, FIELD
+                                                                      Face/Isolation                                                                                                                                      INSTALLATION REQUIRED
+                                                                      Damper
+                                                                      Wiring Conn.                      12" Typ.                           Pressure          34 7/8" Case            Bypass              20 1/8" Minimum  29"         21 3/4" Case
+                                                                                                                                     Ports (4) Typ.                                  Location            Service Area
+                                                                         BP                                                                                                                              (Doors can be
+                                                                                                                                                                                             2 7/8"      Removed from
+                                                                                                                                                                                             Typ.        Hinges.)
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 29                                                                               RA                                          OA        49" Minimum Service AreaDoor
+                                                                                                                                                                                                            (Doors can be RemovedSwing
+
+                                                                                                        16 1/4" Typ.                 49 1/8" Case  FA                                          EA               from Hinges.)Door
+                                                                                                             40 3/4" Typ.                                                                                                                                                           9 3/4"Swing
+                                                                                                                  50 3/4" Overall
+                                                                      Conn. Location
+                                                                         12" Bypass      12 7/8"        Power and                    3/4" -              Door-Interlocked  Leveling                             OA Isolation          8 5/8"
+                                                                                                        Control Wiring                  1 7/8"         Disconnect Switch   Feet (4)                             Damper
+                                                                      Damper           LEFT VIEW        Inlets 7/8"                                                                                             Wiring Conn.
+                                                                      (Not Shown)                                                           Typ.
+
+                                                                                                                                                             FRONT VIEW                                                        RIGHT VIEW
+
+                                                                      MAoIRdFLeOl:WHEC1OXNIFNIGVU[RBAyTpIOaNss]                                                                                                                UNIT MOUNTING & APPLICATION
+                                                                      DArvaailawbleinasgshoTwynpinedi:mUensniointdDrawiminge. nsion
+                                                                      Version: MAY18                                                                                                                                           Can be mounted in any orientation. Airstreams
+                                                                                                                                                                                                                               can not be switched.
+
+                                                                                                                                                                                     HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 1XRT                                                                    Energy Recovery Ventilator
+                                                                           Standard
+
+ROOFTOP UNIT                                                               SPECIFICATIONS
+
+Download specification at:                                                   Ventilation Type:                                                     Options:
+renewaire.com/specifications                                                 Static plate, heat and humidity transfer                              Qty. 2, Variable Speed/ECM - Direct Drive Motors
+                                                                             Typical Airflow Range: 250-870 CFM
+                                                                             AHRI 1060 Certified Core: One L125-G5                                     (see HE1XRT EC Motor submittal) -
+                                                                             Standard Features:                                                       0.5 HP 120V/1Ph/60HZ,
+                                                                             Non-fused disconnect                                                     0.5 HP 208-230V/1Ph/60HZ
+                                                                             24 VAC transformer/relay package                                      Independent blower control
+                                                                             Cross-core differential pressure ports                                Onboard variable frequency drives (VFDs) -
+                                                                             Filters:                                                                 one or both airstreams
+                                                                             Total qty. 2, MERV 8: 20" x 20" x 2"                                  Fused disconnect
+                                                                             Unit Dimensions & Weight:                                             Integrated programmable controls -
+                                                                             81" L x 40 1/4" W x 44" H                                                enhanced, premium
+                                                                             243-346 lbs., varies by option(s)                                     Class 1 low leakage motorized isolation dampers -
+                                                                             Max. Shipping Dimensions & Weight (on pallet):                           OA, RA or both airstreams
+                                                                             96" L x 47" W x 50" H                                                 Qty. 2, Factory mounted filter alarms -
+                                                                             441 lbs.                                                                 both airstreams
+                                                                             Motor(s):                                                             Double wall construction
+                                                                             Qty. 2, 0.75 HP ea., Direct drive blower/standard                     Exterior paint - white, custom colors
+
+                                                                                motor packages                                                     Accessories:
+                                                                                                                                                   Filters - MERV 13, 2" (shipped loose)
+                                                                           Thermal Performance Ratings G5 2015.2.xlsx                              Backdraft damper 12"
+                                                                                                                                                   Solid state speed control kit - 115V,
+
+                                                                                                                                                      208-230V (1 required per motor)
+                                                                                                                                                   Roof curb - standard 14"
+                                                                                                                                                   Curb wind clip
+                                                                                                                                                   Engineered combo curb for Trane RTU
+                                                                                                                                                   Engineered combo curb for Carrier RTU
+                                                                                                                                                   Digital time clock - wall mount (TC7D-W),
+
+                                                                                                                                                      in exterior enclosure (TC7D-E)
+                                                                                                                                                   Carbon dioxide sensor/control -
+
+                                                                                                                                                      wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                                   IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                      duct mount (IAQ-D)
+                                                                                                                                                   Motion occupancy sensor/control -
+
+                                                                                                                                                      ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                                   Smoke Detector - duct mount (SD-D)
+                                                                                                                                                   Electric duct heater - EK series (1–175 kW);
+
+                                                                                                                                                      designed for indoor ductwork installation only
+                                                                                                                                                   Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                      (50-400 MBH), insHtaEll1eXd d(IoOwMns)tream of any fans
+
+AIRFLOW PERFORMANCE
+
+    Motor HP                                                                     External Static Pressure (Inches Water Column)
+     Phase
+                                   0.0                              0.5                      1.0                     1.25                                   1.45              1.75
+
+    0.75            950 CFM                                     820 CFM                  730 CFM                       650 CFM                            560 CFM           250 CFM
+Single Phase      1,630 Watts                                 1,475 Watts              1,385 Watts                   1,300 Watts                        1,220 Watts       1,080 Watts
+
+    0.75            950 CFM                                     820 CFM                  730 CFM                       650 CFM                            560 CFM           250 CFM
+Three Phase       1,430 Watts                                 1,255 Watts              1,155 Watts                   1,060 Watts                          955 Watts         685 Watts
+
+Note: Watts is for the entire unit (2 motors).
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                            CORE PERFORMANCE
+                     Standard Electrical Specifications
+                                                                                        Optional Factory Installed                                      Airflow (CFM)
+                                                                                       VFD Electrical Specifications
+
+                                                   Min.                 Max.                 Min.          Max.            Effectiveness (%)       200  400          600  800  1000
+                                                    Cir.            Overcurrent               Cir.     Overcurrent
+HP  Volts     HZ  Phase                    FLA     Amps             Protection      FLA      Amps      Protection                             90%
+                                        per motor                                per motor
+                                                                       Device                             Device
+                                                                         25                                                                   70%
+
+0.75 120 60 Single                      9.0                   20.3       15
+
+0.75 208-230 60 Single                  4.5                   10.1       15                                                                   50%
+
+0.75 277 60 Single                      3.9                   8.8        15                                                                   30%
+                                                                                                                                                     At AHRI 1060 standard conditions.
+0.75 208-230 60 Three 1.7-2.3 5.2                                        15      1.7-2.3 5.7           15                                            See all AHRI certified ratings at www.ahrinet.org.
+
+0.75 460 60 Three 1.15                                        2.6                      1.15       2.8  15
+
+      Specifications may be subject to change without notice.
+30 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1XRT (RTV/RTR) Energy Recovery Ventilator Standaarrdd or EC Motor Option
+
+                                                                                                     22 5/8"           RA Damper                                                                                                                                      ABBREVIATIONS
+                                                                                                      Case             Location                                                                                                                                       EA: Exhaust Air to outside
+                                                                                                                       (Optional)                                                                                                                                     OA: Outside Air intake
+                                                                                        RA                             (Recessed 3/4")                                                     CURB 1X                                                                    RA: Room Air to be exhausted
+                                                                      10 1/4" X 12 1/2"                                                                                                                                                                               FA: Fresh Air to inside
+                                                                                                                    35 1/4" Minimum                                               14 1/2"                                                                             RTV: Rooftop Vertical RA & FA
+                                                                                Opening                               Service Area                                                                                                                                    RTR: Rooftop Vertical RA Only
+                                                                                                                                                                                                       RA                                                             INSTALLATION ORIENTATION
+                                                                      51" Case                                                 Door                                                                                        14 1/4"                                    Unit must be installed in orientation
+                                                                           10 3/4" 10 1/4"  10 1/8"                            Swing        10 1/8"                                                                                  44" I.D.                         shown.
+                                                                                                                                                                  61 1/8" Minimum                                                                                     NOTE:
+                                                                                                                                                                     Service Area                                                                                     1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                         47 3/4" O.D.                                                                 DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                                      NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                                      2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                                      TO CHANGE WITHOUT NOTICE.
+
+                                                                                               7 1/2"                                                                                                      A               A  14 1/4"                                 CURB CROSS-SECTION A-A (TYP.)
+
+                                                                                                                                     Door                                                                     FA
+                                                                                                                                     Swing
+                                                                                                 FA (RTV)                                                                                                                                                             1 1/2" X 1/4"              1 7/8"
+                                                                                          7 1/4" X 6 1/8"                                                                                                                                                             Neoprene Gasket
+                                                                                                Opening
+                                                                                                                                                                                  18 1/4" O.D.                                                                        3/4" X 3 1/2"              44"
+                                                                                                       TOP VIEW                                                                                                                                                       Wooden Nailer                 Overall
+                                                                                                                                                                                               TOP VIEW
+                                                                                                                                                                                                                                                                                             3"                            14"
+
+                                                                                                                                                                                                                                                                      SECTION A-A
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 31                                                                        EA Outlet                                                         81" Overall                         2"                                               40 1/4" Overall
+                                                                                                                                               at Back                                                                                         Typ.
+                                                                                                                                                                                                              45 3/4"                                                                            20 1/8"
+                                                                                                                                               E-Box                                                          Lift Lugs                                   OA                                     Lift Lugs
+
+                                                                          EA                                        21 1/2"                 Disconnect                                                                                                Pressure Ports
+                                                                                                                       Wiring                      Switch                                                                                             (4) Typ.
+                                                                      FA (RTR)
+                                                                      16"X12"       41"                             6 5/8"
+                                                                      Duct Receiving   Case
+                                                                      Flange
+                                                                                                                                                       FA   RTR                                                                                                       OA Damper
+                                                                                                                                                           ONLY                                                                                                           Location
+
+                                                                                                                                                                                                                                                                        (Optional)
+
+                                                                                                          1 1/2"                                CL 5 5/8" Power In                                      FA                 RA
+
+                                                                                                     CL 15 1/4"                                 CL 2 1/2" Control In                                    RTV
+                                                                                                       Wiring                                   (2) 7/8" holes for                                     ONLY
+                                                                                                                                                wiring in bottom of
+                                                                                                     LEFT VIEW                              HERT eEx-cBepot 6xx 8x, LERT  FRONT VIEW HERT except 6x 8x, LERT                                                                                     RIGHT VIEW
+
+                                                                      MoAdIReFl:LHOEW1XCROTNVF/IRGTURRATION                                 RTV                                   RTR                                                                                                            UNIT MOUNTING & APPLICATION
+                                                                      DrAavawilainblegasTyshpowen:: Unit Dimension
+                                                                      Version: MAY18                                           EA                      OA                 EA                           OA                                                                                        Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                                                                                                                                 be switched.
+                                                                                                                                                                              FA
+
+                                                                                                                                            FA                                    RA
+                                                                                                                                                   RA
+
+                                                                                                                                                                                                                                       HE-SERIES
+                                                                                                                                                                                                                                                                                                                                     SPECIFICATIONS & DIMENSIONS
+
+        Specifications may be subject to change without notice.
+32 RENEWAIRE.COM 1.800.627.4499
+HE1XRT (RTH/RTF) Energy Recovery Ventilator Standaarrdd or EC Motor Option
+
+                                     22 5/8"                                                                                               CURB 1X         14 1/4"                                ABBREVIATIONS
+                                      Case                                                                                                                           44" I.D.                     EA: Exhaust Air to outside
+                                                                                                                                  14 1/2"                                                         OA: Outside Air intake
+                                                           35 1/4" Minimum                                                                                                                        RA: Room Air to be exhausted
+                                                              Service Area                                                                             RA                                         FA: Fresh Air to inside
+                                                                                                                                                                                                  RTF: Rooftop Vertical FA Only
+51" Case                                                       Door                       61 1/8" Minimum                                                                                         RTH: Rooftop Horizontal RA & FA
+     10 3/4"                                                   Swing                         Service Area                                                                                         INSTALLATION ORIENTATION
+                                                                                                                                                                                                  Unit must be installed in orientation
+                 7 1/2"                                                                                     FA                                                                                    shown.
+                                                       Door                                                                                                                                       NOTE:
+                                                       Swing                                                     47 3/4" O.D.                                                                     1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                  DIMENSIONS ARE ROUNDED TO THE
+                    FA (RTF)                                                                                                                                                                      NEAREST EIGHTH OF AN INCH.
+            7 1/4" X 6 1/8"                                                                                                                                                                       2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                  TO CHANGE WITHOUT NOTICE.
+                  Opening
+                                                                 10 1/4"                                                              A                    A  14 1/4"                             CURB CROSS-SECTION A-A (TYP.)
+                         TOP VIEW
+                                                                                                                                         FA
+
+                                                                                                                                                                                                  1 1/2" X 1/4"              1 7/8"
+                                                                                                                                                                                                  Neoprene Gasket
+
+                                                                                                                             18 1/4" O.D.                                                         3/4" X 3 1/2"              44"
+                                                                                                                                                                                                  Wooden Nailer                 Overall
+                                                                                                                                          TOP VIEW
+                                                                                                                                                                                                                         3"                            14"
+                                                                                                                                                                                                                                                             6 5/8"
+                                                                                                                                                                                                  SECTION A-A
+
+                                                                                                                                         81" Overall                              2"              OA Damper                    40 1/4" Overall
+                                                                                                                                                                               Typ.                   Location
+                                                                          EA Outlet                                                      45 3/4"                                                                             20 1/8"
+                                                                             at Back                                                     Lift Lugs                                                  (Optional)               Lift Lugs
+
+                                                                               E-Box
+
+EA                                            21 1/2"                                                                                                                                 OA
+                                                 Wiring
+                                                                 Disconnect
+    41"                                                                 Switch                                                                                                    Pressure Ports
+       Case                                                                                                                                                                       (4) Typ.
+                                              6 5/8"
+                                                                               FA          RTH                                                                                 RA
+                                                                                          ONLY
+                                                                                                                                                                                                                                                                     1 1/2"
+
+FA (RTH)             1 1/2"                                      CL 5 5/8" Power In                                                                                            5" Damper          RA                                 RA Damper
+16"X12"                                                                                                                                                                        Frames Typ.        16" X 12"                          Location
+Duct Receiving  CL 15 1/4"                                       CL 2 1/2" Control In                                              FA                                                             Duct Receiving                     (Optional)
+Flange            Wiring                                         (2) 7/8" holes for                                                                                                               Flange
+                                                                 wiring in bottom of                                                RTF
+                LEFT VIEW                                                                                                         ONLY
+
+                                                                 E-Box                                                                                                                                                       RIGHT VIEW
+
+                                                         HERT except 6x 8x, LERT                FRONT VIEW HERTexcept 6x 8x, LERT
+
+MoAdIReFl:LROTWH/CROTFNFIGURATION                                         RTH                                                RTF                                                                                             UNIT MOUNTING & APPLICATION
+DrAavawilainblegasTyshpowen:: Unit Dimension
+Version: MAY18                                           EA                           OA  EA                                      OA                                                                                         Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                                                             be switched.
+                                                             FA                       RA                                          RA
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
+
+                                                                      FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 33
+SPECIFICATIONS & DIMENSIONS
+
+HE 1XRT                                                              Energy Recovery Ventilator
+                                                                     EC Motor Option
+
+ROOFTOP UNIT                                                         SPECIFICATIONS
+
+                                                                     Ventilation Type:                                                                                      Options:
+
+                                                                     Static plate, heat and humidity transfer                                                               Fused disconnect
+
+                                                                     Typical Airflow Range: 250-1,100 CFM                                                                    Integrated programmable controls -
+                                                                     AHRI 1060 Certified Core: One L125-G5                                                                      enhanced, premium
+
+                                                                                                                                                                            Class 1 low leakage motorized isolation dampers -
+
+                                                                     Standard Features:                                                                                        OA, RA or both airstreams
+                                                                     Non-fused disconnect                                                                                   Qty. 2, Factory mounted filter alarms -
+                                                                     24 VAC transformer/relay package
+                                                                     Cross-core differential pressure ports                                                                    both airstreams
+                                                                                                                                                                            Double wall construction
+                                                                     Filters:                                                                                               Exterior paint - white, custom colors
+                                                                     Total qty. 2, MERV 8: 20" x 20" x 2"
+                                                                                                                                                                            Accessories:
+                                                                     Unit Dimensions & Weight:                                                                              Filters - MERV 13, 2" (shipped loose)
+                                                                     81" L x 40 1/4" W x 42 1/4" H                                                                          Backdraft damper 12"
+                                                                     246-366 lbs., varies by option(s)                                                                      Potentiometer speed control - remote installed
+                                                                                                                                                                            Roof curb - standard 14"
+
+                                                                     Max. Shipping Dimensions & Weight (on pallet): Curb wind clip
+
+                                                                     96" L x 47" W x 50" H                                                                                  Engineered combo curb for Trane RTU
+
+Download specification at:                                           458 lbs.                                                                                               Engineered combo curb for Carrier RTU
+renewaire.com/specifications
+                                                                     Motor(s):                                                                                              Digital time clock - wall mount (TC7D-W),
+EC MOTOR OPTION OPERATING RANGE                                      Qty. 2, 0.5 HP ea., Direct drive EC blower/motor                                                          in exterior enclosure (TC7D-E)
+
+                                                                        packages                                                                                            Carbon dioxide sensor/control -
+                                                                                                                                                                               wall mount (CO2-W), duct mount (CO2-D)
+
+                                                                                                                                                                            IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                                            duct mount (IAQ-D)
+
+                                                                                                                                                                            Motion occupancy sensor/control -
+
+                                                                                                                                                                            ceiling mount (MC-C), wall mount (MC-W)
+
+                                                                                                                                                                            Smoke Detector - duct mount (SD-D)
+
+                                                                                                                                                                            Electric duct heater - EK series (1–175 kW);
+
+                                                                                                                                                                            designed for indoor ductwork installation only
+
+                                                                                                                                                                            Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                              HE1X-RT ECM (50-400 MBH), installed downstream of any fans
+
+                                                                                     1.75
+
+        HE1XRT EC MOTOR
+
+     Sample Points Depicted in Larger Dots
+
+Airflow        External Static     Unit Power                                                              1.50                                          966
+(CFM)            Pressure        Consumption                                                              1.25                                     921
+
+              (Inches Water         (Watts)                                                                                                                                 1061
+                 Column)
+
+314                     0.04                            88           External Static Pressure (in. w.g.)                                      665               898
+
+433                     0.07                            153                                               1.00                                                                         1074
+        Thermal Performance Ratings G5 2015.2.xlsx                                                                                   HE1X (IOM)                             881
+
+627                     0.15                            321                                                                                                630
+
+770                     0.24                            572                                                                                                                                  1073
+
+                                                                                                          0.75                       397           612                      864
+
+901                     0.33                            838
+
+988                     0.41                            1053                                                                             380                                          851         1065
+
+                                                                                                                                                                594
+
+291                     0.11                            93                                                0.50                            368
+                                                                                                                                             354
+                                                                                                                         177                    339             582                        838     1053
+                                                                                                                          168                      321            572
+394                     0.20                            163                                                                                           298             564
+
+561                     0.42                            368                                               0.25 99        163                                                                 828         1041 (Watts)
+                                                                                                                           159
+                                                                                                                               156
+692                     0.65                            612
+                                                                                                                     91        153
+                                                                                                                                151
+803                     0.89                            881                                                          87
+                                                                                                          0.00
+
+857                     1.01                            1074                                                    250                 500                         750                                1000                 1250
+
+Note: Watts is for the entire unit.                                                                                                                          Airflow (cfm)
+Note: Airflow performance includes effect of clean, standard filter                                                    = Actual tested sample points
+supplied with unit.
+                                                                     CORE PERFORMANCE
+                                                                                            Airflow (CFM)
+
+ELECTRICAL DATA                                                      Effectiveness (%)                          200      400        600       800               1000
+
+ HP Volts HZ Phase                                          Max.                                          90%
+ 0.5 120 60 Single                                      Overcurrent
+ 0.5 208-230 60 Single   FLA     Min.                   Protection                                        70%
+                         per      Cir.
+                        motor    Amps                      Device                                         50%
+
+                         8.1     18.2                        25
+
+                         4.8     10.8                        15
+
+                                                                                                          30%
+                                                                                                                 At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+Specifications may be subject to change without notice.
+
+34 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1XRT (RTV/RTR) Energy Recovery Ventilator SEtCanMdoatrodr oOrpEtiConMotor Option
+
+                                                                                                     22 5/8"           RA Damper                                                                                                                                      ABBREVIATIONS
+                                                                                                      Case             Location                                                                                                                                       EA: Exhaust Air to outside
+                                                                                                                       (Optional)                                                                                                                                     OA: Outside Air intake
+                                                                                        RA                             (Recessed 3/4")                                                     CURB 1X                                                                    RA: Room Air to be exhausted
+                                                                      10 1/4" X 12 1/2"                                                                                                                                                                               FA: Fresh Air to inside
+                                                                                                                    35 1/4" Minimum                                               14 1/2"                                                                             RTV: Rooftop Vertical RA & FA
+                                                                                Opening                               Service Area                                                                                                                                    RTR: Rooftop Vertical RA Only
+                                                                                                                                                                                                       RA                                                             INSTALLATION ORIENTATION
+                                                                      51" Case                                                 Door                                                                                        14 1/4"                                    Unit must be installed in orientation
+                                                                           10 3/4" 10 1/4"  10 1/8"                            Swing        10 1/8"                                                                                  44" I.D.                         shown.
+                                                                                                                                                                  61 1/8" Minimum                                                                                     NOTE:
+                                                                                                                                                                     Service Area                                                                                     1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                         47 3/4" O.D.                                                                 DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                                      NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                                      2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                                      TO CHANGE WITHOUT NOTICE.
+
+                                                                                               7 1/2"                                                                                                      A               A  14 1/4"                                 CURB CROSS-SECTION A-A (TYP.)
+
+                                                                                                                                     Door                                                                     FA
+                                                                                                                                     Swing
+                                                                                                 FA (RTV)                                                                                                                                                             1 1/2" X 1/4"              1 7/8"
+                                                                                          7 1/4" X 6 1/8"                                                                                                                                                             Neoprene Gasket
+                                                                                                Opening
+                                                                                                                                                                                  18 1/4" O.D.                                                                        3/4" X 3 1/2"              44"
+                                                                                                       TOP VIEW                                                                                                                                                       Wooden Nailer                 Overall
+                                                                                                                                                                                               TOP VIEW
+                                                                                                                                                                                                                                                                                             3"                            14"
+
+                                                                                                                                                                                                                                                                      SECTION A-A
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 35                                                                        EA Outlet                                                         81" Overall                         2"                                               40 1/4" Overall
+                                                                                                                                               at Back                                                                                         Typ.
+                                                                                                                                                                                                              45 3/4"                                                                            20 1/8"
+                                                                                                                                               E-Box                                                          Lift Lugs                                   OA                                     Lift Lugs
+
+                                                                          EA                                        21 1/2"                 Disconnect                                                                                                Pressure Ports
+                                                                                                                       Wiring                      Switch                                                                                             (4) Typ.
+                                                                      FA (RTR)
+                                                                      16"X12"       41"                             6 5/8"
+                                                                      Duct Receiving   Case
+                                                                      Flange
+                                                                                                                                                       FA   RTR                                                                                                       OA Damper
+                                                                                                                                                           ONLY                                                                                                           Location
+
+                                                                                                                                                                                                                                                                        (Optional)
+
+                                                                                                          1 1/2"                                CL 5 5/8" Power In                                      FA                 RA
+
+                                                                                                     CL 15 1/4"                                 CL 2 1/2" Control In                                    RTV
+                                                                                                       Wiring                                   (2) 7/8" holes for                                     ONLY
+                                                                                                                                                wiring in bottom of
+                                                                                                     LEFT VIEW                              HERT eEx-cBepot 6xx 8x, LERT  FRONT VIEW HERT except 6x 8x, LERT                                                                                     RIGHT VIEW
+
+                                                                      MoAdIReFl:LHOEW1XCROTNVF/IRGTURRATION                                 RTV                                   RTR                                                                                                            UNIT MOUNTING & APPLICATION
+                                                                      DrAavawilainblegasTyshpowen:: Unit Dimension
+                                                                      Version: MAY18                                           EA                      OA                 EA                           OA                                                                                        Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                                                                                                                                 be switched.
+                                                                                                                                                                              FA
+
+                                                                                                                                            FA                                    RA
+                                                                                                                                                   RA
+
+                                                                                                                                                                                                                                       HE-SERIES
+                                                                                                                                                                                                                                                                                                                                     SPECIFICATIONS & DIMENSIONS
+36 RENEWAIRE.COM 1.800.627.4499
+HE1XRT (RTH/RTF) Energy Recovery Ventilator EStCanMdoatrodr oOrpEtiConMotor Option
+
+                                     22 5/8"                                                                                               CURB 1X         14 1/4"                                ABBREVIATIONS
+                                      Case                                                                                                                           44" I.D.                     EA: Exhaust Air to outside
+                                                                                                                                  14 1/2"                                                         OA: Outside Air intake
+                                                           35 1/4" Minimum                                                                                                                        RA: Room Air to be exhausted
+                                                              Service Area                                                                             RA                                         FA: Fresh Air to inside
+                                                                                                                                                                                                  RTF: Rooftop Vertical FA Only
+51" Case                                                       Door                       61 1/8" Minimum                                                                                         RTH: Rooftop Horizontal RA & FA
+     10 3/4"                                                   Swing                         Service Area                                                                                         INSTALLATION ORIENTATION
+                                                                                                                                                                                                  Unit must be installed in orientation
+                 7 1/2"                                                                                     FA                                                                                    shown.
+                                                       Door                                                                                                                                       NOTE:
+                                                       Swing                                                     47 3/4" O.D.                                                                     1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                  DIMENSIONS ARE ROUNDED TO THE
+                    FA (RTF)                                                                                                                                                                      NEAREST EIGHTH OF AN INCH.
+            7 1/4" X 6 1/8"                                                                                                                                                                       2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                  TO CHANGE WITHOUT NOTICE.
+                  Opening
+                                                                 10 1/4"                                                              A                    A  14 1/4"                             CURB CROSS-SECTION A-A (TYP.)
+                         TOP VIEW
+                                                                                                                                         FA
+
+                                                                                                                                                                                                  1 1/2" X 1/4"              1 7/8"
+                                                                                                                                                                                                  Neoprene Gasket
+
+                                                                                                                             18 1/4" O.D.                                                         3/4" X 3 1/2"              44"
+                                                                                                                                                                                                  Wooden Nailer                 Overall
+                                                                                                                                          TOP VIEW
+                                                                                                                                                                                                                         3"                            14"
+                                                                                                                                                                                                                                                             6 5/8"
+                                                                                                                                                                                                  SECTION A-A
+
+                                                                                                                                         81" Overall                              2"              OA Damper                    40 1/4" Overall
+                                                                                                                                                                               Typ.                   Location
+                                                                          EA Outlet                                                      45 3/4"                                                                             20 1/8"
+                                                                             at Back                                                     Lift Lugs                                                  (Optional)               Lift Lugs
+
+                                                                               E-Box
+
+EA                                            21 1/2"                                                                                                                                 OA
+                                                 Wiring
+                                                                 Disconnect
+    41"                                                                 Switch                                                                                                    Pressure Ports
+       Case                                                                                                                                                                       (4) Typ.
+                                              6 5/8"
+                                                                               FA          RTH                                                                                 RA
+                                                                                          ONLY
+                                                                                                                                                                                                                                                                     1 1/2"
+
+FA (RTH)             1 1/2"                                      CL 5 5/8" Power In                                                                                            5" Damper          RA                                 RA Damper
+16"X12"                                                                                                                                                                        Frames Typ.        16" X 12"                          Location
+Duct Receiving  CL 15 1/4"                                       CL 2 1/2" Control In                                              FA                                                             Duct Receiving                     (Optional)
+Flange            Wiring                                         (2) 7/8" holes for                                                                                                               Flange
+                                                                 wiring in bottom of                                                RTF
+                LEFT VIEW                                                                                                         ONLY
+
+                                                                 E-Box                                                                                                                                                       RIGHT VIEW
+
+                                                         HERT except 6x 8x, LERT                FRONT VIEW HERTexcept 6x 8x, LERT
+
+MoAdIReFl:LROTWH/CROTFNFIGURATION                                         RTH                                                RTF                                                                                             UNIT MOUNTING & APPLICATION
+DrAavawilainblegasTyshpowen:: Unit Dimension
+Version: MAY18                                           EA                           OA  EA                                      OA                                                                                         Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                                                             be switched.
+                                                             FA                       RA                                          RA
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
+
+                                                                      FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 37
+SPECIFICATIONS & DIMENSIONS
+
+HE 1XRTC                                                                               Energy Recovery Ventilator
+                                                                                       Standard
+
+ROOFTOP UNIT                                                                           SPECIFICATIONS
+Direct Connect
+
+Download specification at:                                                             Ventilation Type:                                               Options:
+renewaire.com/specifications                                                           Static plate, heat and humidity transfer                        Qty. 2, Variable Speed/ECM - Direct Drive Motors -
+
+                                                                                       Typical Airflow Range: 500-900 CFM                                  (see HE1XRTC EC Motor submittal) -
+                                                                                                                                                          0.5 HP 120V/1Ph/60HZ,
+                                                                                       AHRI 1060 Certified Core: One L125-G5                               0.5 HP 208-230V/1Ph/60HZ
+                                                                                                                                                       Independent blower control
+                                                                                       Standard Features:                                              Fused disconnect
+                                                                                       Non-fused disconnect                                            Integrated programmable controls -
+                                                                                       24 VAC transformer/relay package                                   enhanced, premium
+                                                                                       Cross-core differential pressure ports                          Qty. 2, Factory mounted filter alarms -
+                                                                                                                                                          both airstreams
+                                                                                       Filters:                                                        Double wall construction
+                                                                                       Total qty. 2, MERV 8: 20" x 20" x 2"                            Exterior paint - white, custom colors
+
+                                                                                       Unit Dimensions & Weight:                                       Accessories:
+                                                                                       73 1/4" L x 40 1/4" W x 50" H                                   Filters - MERV 13, 2" (shipped loose)
+                                                                                       269-356 lbs., varies by option(s)                               Solid state speed control kit - 115V,
+
+                                                                                       Max. Shipping Dimensions & Weight (on pallet):                     208-230V (1 required per motor)
+                                                                                       96" L x 47" W x 50" H                                           RTC transition kit - for vertical RTU, for horizontal RTU
+                                                                                       450 lbs.                                                        Rooftop RTC transition paint - white, custom colors
+                                                                                                                                                       Digital time clock - wall mount (TC7D-W),
+                                                                                       Motor(s):
+                                                                                       Qty. 2, 0.75 HP ea., Direct drive blower/standard                  in exterior enclosure (TC7D-E)
+                                                                                                                                                       Carbon dioxide sensor/control -
+                                                                                          motor packages
+                                                                                                                                                          wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                                       IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                          duct mount (IAQ-D)
+                                                                                                                                                       Motion occupancy sensor/control -
+
+                                                                                                                                                          ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                                       Smoke Detector - duct mount (SD-D)
+
+AIRFLOW PERFORMANCE                                                                    Note: Electric Duct Heater and Indirect Gas-Fired Duct Furnace are not available on RTC units.
+
+                                                        Tie-In Directly to Rooftop A/C Unit                                                            Unit Ducted Independently
+
+Damper          Total Watts                             Static Pressure in Adjacent Air Handler                                                              External Static Pressure
+Position   1 Phase 3 Phase                                       (Inches Water Column)                                                                       (Inches Water Column)
+
+                                                       -0.75                           -0.5                               -0.25               0.0            +0.25                +0.5                    +0.75
+
+                                                EA            FA                   EA                     FA         EA          FA       EA       FA  EA                 FA  EA        FA            EA         FA
+
+100% Open  1,295        1,135                   735 1035 865 990                                                     920         945 975 890 920 845 865 790 735 605
+
+65% Open   1,285        1,088 715 995 825 950 880 905 935 855 880 805 825 760 715 605
+
+55% Open   1,275        1,074 715 980 815 935 870 890 925 845 870 795 815 755 715 615
+
+45% Open   1,265        1,030 680 940 790 895 840 850 895 810 840 760 790 720 680 570
+
+35% Open   1,265        951                     630 865 745 825 795 785 850 745 795 700 745 665 630 515
+25% Open
+           1T,h2e65rmal Pe8rf6o6rmance57R0atings7G955 20157.020.xlsx 755 750 715 HE810X0 (IOM6)80 750 640 700 605 570 440
+
+15% Open   1,260        774                     510 725 655 685 705 645 750 615 705 580 655 545 510 365
+
+Note: Watts is for the entire unit (2 motors).
+
+Note: Airflow performance includes effect
+of clean, standard filter supplied with unit.
+
+                                                Installation Details - Applicable to all RTC units                                        Refer to IOM for more details.
+
+                                                www.renewaire.com (800) 627- 4499  support@renewaire.com
+
+ELECTRICAL DATA                                                                     CORE PERFORMANCE
+
+                         FLA                    Min.        Max.                                                          Airflow (CFM)
+                         per                     Cir.   Overcurrent
+HP Volts HZ Phase       motor                   Amps    Protection                     Effectiveness (%)        200       400        600      800      1000
+                                                                                                          90%
+0.75 120 60 Single       9.0                    20.3       Device
+0.75 208-230 60 Single                                                                                    70%
+                         4.5                    10.1         25
+
+                                                             15
+
+0.75 277 60 Single 3.9 8.8                                    15                                          50%
+
+0.75 208-230 60 Three 1.7-2.3 5.2                             15
+
+0.75 460 60 Three 1.15 2.6                                    15                                          30%
+                                                                                                                 At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+Specifications may be subject to change without notice.
+
+38 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1XRTC Energy Recovery Ventilator Standaarrdd or EC Motor Option
+
+                                                                                         22 1/2" Case                                                                                                             ABBREVIATIONS
+                                                                                                                                                                                                                  EA: Exhaust Air to outside
+                                                                                                                          33 3/4" Minimum                                                                         OA: Outside Air intake
+                                                                                                                            Service Area                                                                          RA: Room Air to be exhausted
+                                                                                                                                                                                                                  FA: Fresh Air to inside
+                                                                                                                          Door                                                                                    INSTALLATION ORIENTATION
+                                                                                                                          Swing                                                                                   Unit must be installed in orientation
+                                                                      51" Case                                                                                                                                    shown.
+                                                                                                                                                     51" Minimum                                                  NOTE
+                                                                                                                                                         Service Area                                             1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                  DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                  NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                  2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                  TO CHANGE WITHOUT NOTICE.
+
+                                                                                                                          Door
+                                                                                                                          Swing
+
+                                                                                         TOP VIEW
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 39                              2" Typ.                                                              73 1/4" Overall                            40 1/4" Overall
+                                                                                                                                                                                     45 3/4"
+                                                                                           20 1/8"                                                                                                                                     2"
+                                                                                         Lifting Lugs                                                                             Lifting Lugs                      16"
+
+                                                                                                                          Control Wiring                                            EA Outlet
+                                                                                                                               Inlet 7/8"
+                                                                                                                                                                                    at Back
+
+                                                                      49 7/8" OverallEA                                                                                                                     FA    11"
+                                                                           41 1/4" Case                                                                                                                       RA     Typ.
+                                                                                                                                                Disconnect
+                                                                                                                                                Switch                                                                           3 1/2"
+                                                                                                                                                                                                                                        14 1/2" to 17 1/2"
+                                                                                                                               OA                                                                                                           Height
+                                                                                                                                                                                                                                               Adjustment
+
+                                                                                                                                 Power Wiring
+                                                                                                                                    Inlet 7/8"
+
+                                                                                                  LEFT VIEW                                                                                 Pressure              8 3/8"RIGHT VIEW
+                                                                                                                                                                                            Ports (4) Typ.
+                                                                         AIRFLOW CONFIGURATION                                                                                                                               UNIT MOUNTING & APPLICATION
+                                                                                                                                                                       FRONT VIEW                                            Must be mounted as shown. Airstreams can not
+                                                                      MoAvdaileabl:leHasEs1hXowRnTiCn dimension drawing.                                                                                                     be switched.
+                                                                      Drawing Type: Unit Dimension                                                                               HE-SERIES
+                                                                      Version: MAY18
+SPECIFICATIONS & DIMENSIONS                                                                                             Energy Recovery Ventilator
+                                                                                                                        EC Motor Option
+HE 1XRTC
+                                                                                                                        SPECIFICATIONS                                                                                     Options:
+ROOFTOP UNIT                                                                                                                                                                                                               Fused disconnect
+Direct Connect                                                                                                          Ventilation Type:                                                                                  Integrated programmable controls -
+                                                                                                                        Static plate, heat and humidity transfer
+Download specification at:                                                                                                                                                                                                    enhanced, premium
+renewaire.com/specifications                                                                                            Typical Airflow Range: 500-1,100 CFM                                                                Qty. 2, Factory mounted filter alarms -
+
+                                                                                                                        AHRI 1060 Certified Core: One L125-G5                                                                  both airstreams
+                                                                                                                                                                                                                           Double wall construction
+                                                                                                                        Standard Features:                                                                                 Exterior paint - white, custom colors
+                                                                                                                        Non-fused disconnect
+                                                                                                                        24 VAC transformer/relay package                                                                   Accessories:
+                                                                                                                        Cross-core differential pressure ports                                                             Filters - MERV 13, 2" (shipped loose)
+                                                                                                                                                                                                                           RTC transition kit - for vertical RTU, for horizontal RTU
+                                                                                                                        Filters:                                                                                           Rooftop RTC transition paint - white, custom colors
+                                                                                                                        Total qty. 2, MERV 8: 20" x 20" x 2"                                                               Digital time clock - wall mount (TC7D-W),
+
+                                                                                                                        Unit Dimensions & Weight:                                                                             in exterior enclosure (TC7D-E)
+                                                                                                                        73 1/4" L x 40 1/4" W x 50" H                                                                      Carbon dioxide sensor/control -
+                                                                                                                        272-358 lbs., varies by option(s)
+                                                                                                                                                                                                                              wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                        Max. Shipping Dimensions & Weight (on pallet):                                                     IAQ sensor - wall mount (IAQ-W),
+                                                                                                                        96" L x 47" W x 50" H
+                                                                                                                        450 lbs.                                                                                              duct mount (IAQ-D)
+                                                                                                                                                                                                                           Motion occupancy sensor/control -
+                                                                                                                        Motor(s):
+                                                                                                                        Qty. 2, 0.5 HP, Direct drive EC blower/                                                               ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                                                                                                           Smoke Detector - duct mount (SD-D)
+                                                                                                                           motor packages
+
+                                                                                                                        Note: Electric Duct Heater and Indirect Gas-Fired Duct Furnace are not available on RTC units.
+
+EC MOTOR OPUTnIOit TNHieEdO1XinP-RtEoTCRAiEArCHTMaInNdGlerRANGE                                                                                       EC MOTOR OPTION OPERATING RANGE
+Tie-In Directly to Rooftop A/C Unit*                                                                                                                  Unit Ducted IndependenHtlEy1*X-RTC ECM
+
+                                                                  Airflow (cfm)                                                                                                      Unit Tied Into Separate Ducts
+
+                                           500  625  750                             875                   1000         1125                    1250        1.25
+                                     0.00                                                                   866
+External Static Pressure (in. w.g.)                          297        559                                907           1040 (Watts)
+                                     -0.25                333          595                                              1050
+                                                     331
+                                                                                                                                                                                           1.00
+                                                                                                                                                      External Static Pressure (in. w.g.)
+                                                296               562
+
+                                     -0.50      Thermal Pe45r1formance Rating8s51G5 2015.2.xlsx                                                                                            0.75 HE1X (IOM)                                  516
+                                                                                                                                                                                                                                471
+                                                                                                 1060                                                                                                                                                             806
+                                                                  630                                                                                                                                                      372
+                                                                                                                                                                                                                                                      654
+                                     -0.75                                                                                                                                                 0.50                 250
+                                                                                                      755                                                                                                                                                                  900
+                                                                                                                                                                                                                                                             718
+                                                                                                                                                                                                                                      444
+
+                                     -1.00                                                                                                                                                 0.25           131              276                   470
+                                                                                                                                                                                                                                277
+                                         HE1X-RTC EA EC                                                                                                                                               94                                                        694  890 watts
+
+                                     -1.25                                                                                                                                                                      139                                   443
+                                                                                                                                                                                                                  140
+                                           Note: Airflow performance includes effect of clean, standard filter supplied with unit.                                                                          89         137         249
+                                              = Actual tested sample points                                                                                                                                89
+                                                                                                                                                                                           0.00                       500  625                   750       875       1000       1125  1250
+                                                                                                                                                                                                250        375
+
+                                                                                                                                                                                                                                 Airflow (cfm)
+
+                                            * See page 38 for installation details.
+
+ELECTRICAL DATA                                                                                                         CORE PERFORMANCE
+
+ HP Volts HZ Phase                                    FLA         Min.                                         Max.                                   Airflow (CFM)
+ 0.5 120 60 Single                                    per          Cir.                                    Overcurrent
+ 0.5 208-230 60 Single                               motor        Amps                                     Protection   Effectiveness (%)        200  400                                        600      800              1000
+                                                                                                                                           90%
+                                                      8.1         18.2                                        Device
+                                                                                                                                           70%
+                                                      4.8         10.8                                          25
+
+                                                                                                                15
+
+                                                                                                                                           50%
+
+                                                                                                                                           30%
+                                                                                                                                                   At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+      Specifications may be subject to change without notice.
+40 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1XRTC Energy Recovery Ventilator SEtCanMdoatrodr oOrpEtiConMotor Option
+
+                                                                                         22 1/2" Case                                                                                                             ABBREVIATIONS
+                                                                                                                                                                                                                  EA: Exhaust Air to outside
+                                                                                                                          33 3/4" Minimum                                                                         OA: Outside Air intake
+                                                                                                                            Service Area                                                                          RA: Room Air to be exhausted
+                                                                                                                                                                                                                  FA: Fresh Air to inside
+                                                                                                                          Door                                                                                    INSTALLATION ORIENTATION
+                                                                                                                          Swing                                                                                   Unit must be installed in orientation
+                                                                      51" Case                                                                                                                                    shown.
+                                                                                                                                                     51" Minimum                                                  NOTE
+                                                                                                                                                         Service Area                                             1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                  DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                  NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                  2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                  TO CHANGE WITHOUT NOTICE.
+
+                                                                                                                          Door
+                                                                                                                          Swing
+
+                                                                                         TOP VIEW
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 41                              2" Typ.                                                              73 1/4" Overall                            40 1/4" Overall
+                                                                                                                                                                                     45 3/4"
+                                                                                           20 1/8"                                                                                                                                     2"
+                                                                                         Lifting Lugs                                                                             Lifting Lugs                      16"
+
+                                                                                                                          Control Wiring                                            EA Outlet
+                                                                                                                               Inlet 7/8"
+                                                                                                                                                                                    at Back
+
+                                                                      49 7/8" OverallEA                                                                                                                     FA    11"
+                                                                           41 1/4" Case                                                                                                                       RA     Typ.
+                                                                                                                                                Disconnect
+                                                                                                                                                Switch                                                                           3 1/2"
+                                                                                                                                                                                                                                        14 1/2" to 17 1/2"
+                                                                                                                               OA                                                                                                           Height
+                                                                                                                                                                                                                                               Adjustment
+
+                                                                                                                                 Power Wiring
+                                                                                                                                    Inlet 7/8"
+
+                                                                                                  LEFT VIEW                                                                                 Pressure              8 3/8"RIGHT VIEW
+                                                                                                                                                                                            Ports (4) Typ.
+                                                                         AIRFLOW CONFIGURATION                                                                                                                               UNIT MOUNTING & APPLICATION
+                                                                                                                                                                       FRONT VIEW                                            Must be mounted as shown. Airstreams can not
+                                                                      MoAvdaileabl:leHasEs1hXowRnTiCn dimension drawing.                                                                                                     be switched.
+                                                                      Drawing Type: Unit Dimension                                                                               HE-SERIES
+                                                                      Version: MAY18
+SPECIFICATIONS & DIMENSIONS
+
+HE 1.5XINH Energy Recovery Ventilator
+                                                                 Standarrdd & Bypass Economizer Option
+
+INDOOR UNIT                                                                SPECIFICATIONS                                                     Options:
+                                                                                                                                              Qty. 2, Variable Speed/ECM - Direct drive motors
+Download specification at:                                                 Ventilation Type:
+renewaire.com/specifications                                               Static plate, heat and humidity transfer                              (see HE1.5XINH EC Motor submittal) -
+                                                                                                                                                 1.0 HP 120V/1Ph/60HZ,
+                                                                           Typical Airflow Range:                                                 1.0 HP 208-230V/1Ph/60HZ
+                                                                           375–1,575 CFM                                                      Independent blower control
+                                                                                                                                              Fused disconnect
+                                                                           AHRI 1060 Certified Core:                                           Integrated programmable controls -
+                                                                           One L62-G5 and one L125-G5                                            enhanced, premium
+                                                                                                                                              Bypass economizer damper
+                                                                           Standard Features:                                                    (see bypass DIM drawing) -
+                                                                           Non-fused disconnect                                                  dry-bulb temperature controls (standard),
+                                                                           24 VAC transformer/relay package                                      enthalpy controls (option)
+                                                                           Cross-core differential pressure ports                             Class 1 low leakage motorized isolation dampers -
+                                                                                                                                                 FA, EA or both airstreams
+                                                                           Filters:                                                           Gravity backdraft dampers
+                                                                           Total Qty. 4, MERV 8: (2) 14" x 20" x 2" and                       Qty. 2, Factory mounted filter alarms -
+                                                                                                                                                 both airstreams
+                                                                              (2) 16" x 20" x 2"                                              Double wall construction
+                                                                                                                                              Exterior paint - white, custom colors
+                                                                           Unit Dimensions & Weight:
+                                                                           48 3/4" L x" 34 1/2" W x 53 3/4" H                                 Accessories:
+                                                                           337-504 lbs., varies by option(s)                                  Filters - MERV 13, 2" (shipped loose)
+                                                                                                                                              Backdraft damper - OA or EA
+                                                                           Max. Shipping Dimensions & Weight (on pallet):                     Digital time clock - wall mount (TC7D-W),
+                                                                           70" L x 47" W x 53" H
+                                                                           571 lbs.                                                              in exterior enclosure (TC7D-E)
+                                                                                                                                              Carbon dioxide sensor/control -
+                                                                           Motor(s):
+                                                                           Qty. 2, 1.0 HP ea., Direct drive standard motorized                   wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                              IAQ sensor - wall mount (IAQ-W),
+                                                                              impeller packages
+                                                                                                                                                 duct mount (IAQ-D)
+                                                                                                                                              Motion occupancy sensor/control -
+
+                                                                                                                                                 ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                              Smoke Detector - duct mount (SD-D)
+                                                                                                                                              Electric duct heater - EK series (1–175 kW)
+                                                                                                                                              Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                 (50-400 MBH), installed downstream of any fans
+
+                       Thermal Performance Ratings G5 2015.2.xlsx                                             HE1.5X (IOM)
+AIRFLOW PERFORMANCE
+
+     Motor HP                                                                                 External Static Pressure (Inches Water Column)
+       Phase
+                             0.0                                  0.25                        0.50            0.75                1.00             1.25                                       1.50
+         1.0
+    Single Phase         1,575 CFM                            1,470 CFM     1,350 CFM                          1,225 CFM          1,090 CFM      950 CFM                                   795 CFM
+                         1,545 Watts                          1,525 Watts  1,500 Watts                        1,475 Watts         1,435 Watts  1,380 Watts                                1,300 Watts
+
+         1.0             1,675 CFM                            1,570 CFM    1,435 CFM                           1,280 CFM          1,115 CFM      940 CFM                                   760 CFM
+    Three Phase          1,410 Watts                          1,400 Watts  1,380 Watts                        1,340 Watts         1,280 Watts  1,210 Watts                                1,135 Watts
+
+Note: Watts is for the entire unit (2 motors).
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                            CORE PERFORMANCE
+
+HP  V  HZ         Phase   FLA         Min.                        Max.                                   Airflow (CFM)
+                          per          Cir.                   Overcurrent
+                         motor        Amps                    Protection   Effectiveness (%)        300  600  900          1,200  1,500
+                                                                                              90%
+                                                                 Device
+
+1.0 120 60 Single 6.5 14.6                                    20
+
+1.0 208-230 60 Single 3.3-3.4 7.7                             15                              70%
+
+1.0 277 60 Single 2.7 6.1                                     15                              50%
+
+1.0 208-230 60 Three 2.2-2.2 5.0                              15
+
+1.0 460 60 Three 1.1 2.5                                      15                              30%
+                                                                                                     At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+      Specifications may be subject to change without notice.
+42 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1.5XINH Energy Recovery Ventilator Standaarrdd or EC Motor Option
+
+                                                                                                                                                                                            42 5/8" Case                                           ABBREVIATIONS
+                                                                                                                                                                                                                                                   EA: Exhaust Air to outside
+                                                                                                                                                                        34 1/2"                                Patch Pan                           OA: Outside Air intake
+                                                                                                                                                                           Overall                             (Opening Used                       RA: Room Air to be exhausted
+                                                                                                                                                                                  32 5/8"                      for Alternative                     FA: Fresh Air to inside
+                                                                                                                                                                                      Case                     Unit Configurations)                INSTALLATION ORIENTATION
+                                                                                                                                                                                                               Typ.                                Unit may be installed in any
+                                                                                                                                                                                                                                                   orientation.
+                                                                                                                                                                                                                                                   NOTE
+                                                                                                                                                                                                                                                   1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                   DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                   NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                   2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                   TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                                                                   3. MIN. DUCT CLEARANCE
+                                                                                                                                                                                                                                                   FROM DAMPER BLADE WHEN FULLY
+                                                                                                                                                                                                                                                   OPENED TO BE 2". SMACNA RULES
+                                                                                                                                                                                                                                                   APPLY.
+
+                                                                                                                                                                                            TOP VIEW
+
+                                                                             EA Damper        18" X 18"                                                                 5" Damper           48 3/4"                                                20 1/8"Minimum
+                                                                                Location      Duct                                                                      Frames Typ.         Overall                                                Service Area
+                                                                                              Receiving                                                                                                                                            (Doors can be
+                                                                              (Optional)      Flange Typ.                                                                                                                                          Removed from Hinges.)
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 43           32"                                      EA                                                                                     OA                    49 3/8"Door
+                                                                                  6"                                                                                                                                                    Minimum ServiceSwing
+                                                                      52 3/4"                 Power Wiring
+                                                                         Case                 Inlet 7/8" dia.                                                                                                                               Area
+                                                                                                                                                                                                                                                                                                           53 5/8"
+                                                                                              Control Wiring                                                            FA                                     RA                                                                                              OverallDoor32"
+                                                                                              Inlet 7/8" dia.                                                                                                                        Swing         6"
+
+                                                                                              FA Damper                                                                 3 1/4"              Door-interlocked         Pressure             24 1/2"
+                                                                                              Location                                                                                      Disconnect Switch        Ports (4) Typ.    18" X 18"
+                                                                      6 3/8" Typ.             (Optional)                                                                                                       1 1/8" Typ.                                                  6 3/8" Typ.
+                                                                                                                                                                                                                                         Duct
+                                                                                                                                                                                                                                      Receiving    RIGHT VIEW
+                                                                                                                                                                                                                                     Flange Typ.
+                                                                                                                                                                                                                                                      UNIT MOUNTING & APPLICATION
+                                                                                   LEFT VIEW                                                                                                FRONT VIEW                                                Can be mounted in any orientation. RA/EA airstream
+                                                                                                                                                                                                                                                      can be switched with OA/FA airstream unless
+                                                                      DMroAAavIdawRilaeFbinLlle:OgaHsWsTEhyo1Cwp.On5eiNnX:dFIiNmUIGenHnUsiiRtonADdTraiImwOinNeg. nsion                                                                                certain options are selected. Duct configuration is
+                                                                      Version: MAY18                                                                                                                                                                  field convertible.
+
+                                                                                                                                                                                                               HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 1.5XINH Energy Recovery Ventilator
+                                                                 EC Motor Option
+
+INDOOR UNIT                                                                SPECIFICATIONS
+
+Download specification at:                                                 Ventilation Type:                                                                                                          Options:
+renewaire.com/specifications                                               Static plate, heat and humidity transfer                                                                                   Fused disconnect
+                                                                           Typical Airflow Range: 375-1,575 CFM                                                                                        Integrated programmable controls -
+EC MOTOR OPTION OPERATING RANGE                                            AHRI 1060 Certified Core:
+                                                                           One L62-G5 and one L125-G5                                                                                                    enhanced, premium
+                                                                           Standard Features:                                                                                                         Bypass economizer damper
+                                                                           Non-fused disconnect
+                                                                           24 VAC transformer/relay package                                                                                              (see bypass DIM drawing) -
+                                                                           Cross-core differential pressure ports                                                                                        dry-bulb temperature controls (standard),
+                                                                           Filters:                                                                                                                      enthalpy controls (option)
+                                                                           Total qty. 4, MERV 8: (2) 14" x 20" x 2" and                                                                               Class 1 low leakage motorized isolation dampers -
+                                                                                                                                                                                                         FA, EA or both airstreams
+                                                                              (2) 16" x 20" x 2"                                                                                                      Gravity backdraft dampers
+                                                                           Unit Dimensions & Weight:                                                                                                  Qty. 2, Factory mounted filter alarms -
+                                                                           48 3/4" L x 34 1/2" W x 53 3/4" H                                                                                             both airstreams
+                                                                           336-504 lbs., varies by option(s)                                                                                          Double wall construction
+                                                                           Max. Shipping Dimensions & Weight (on pallet):                                                                             Exterior paint - white, custom colors
+                                                                           70" L x 47" W x 53" H
+                                                                           571 lbs.                                                                                                                   Accessories:
+                                                                           Motor(s):                                                                                                                  Filters - MERV 13, 2" (shipped loose)
+                                                                           Qty. 2, 1.0 HP ea., Direct drive EC motorized                                                                              Backdraft damper - OA or EA
+                                                                                                                                                                                                      Potentiometer speed control - remote installed
+                                                                              impeller packages                                                                                                       Digital time clock - wall mount (TC7D-W),
+
+                                                                                                                       HE1.5X-IN ECM                                                                     in exterior enclosure (TC7D-E)
+                                                                                                                                                                                                      Carbon dioxide sensor/control -
+
+                                                                                                                                                                                                         wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                                                                                      IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                                                                         duct mount (IAQ-D)
+                                                                                                                                                                                                      Motion occupancy sensor/control -
+
+                                                                                                                                                                                                         ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                                                                                      Smoke Detector - duct mount (SD-D)
+                                                                                                                                                                                                      Electric duct heater - EK series (1–175 kW)
+                                                                                                                                                                                                      Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                                                                         (50-400 MBH), installed downstream of any fans
+
+                                                                                                      1.75
+
+                HE1.5XINH EC MOTOR
+
+     Sample Points Depicted in Larger Dots
+
+                External Static                                                                                                    1.50                                                       965
+                   Pressure
+Airflow                                       Unit Power                                                                                                                                                          1006
+(CFM)           (Inches Water               Consumption                                                                                                                         698
+                   Column)
+                                               (Watts)                                                                             1.25
+
+630                                  0.07                     189          External Static Pressure (in. w.g.)
+
+807             Therma0l.P12erformance Ratin31g4s G5 2015.2.xlsx 1.00                                                                                                                                                       1017
+
+                                                                                                                                                                           HE1.5X (IO72M7 )
+
+1014                                 0.20                     502
+
+1222                                 0.28                     735                                                                                                     475                        735                              1022
+
+                                                                                                                                   0.75
+
+1430                                 0.39                     1015                                                                                                         493                        739
+
+                                                                                                                                                                                     498                                                1021
+
+513                                  0.20                     185                                                                  0.50                296                                                           739
+                                                                                                                                                                                          501
+656                                  0.33                     310                                                                                           306
+
+                                                                                                                                                                 310                             502                                          1015
+                                                                                                                                                                                                       502                                           1006 (Watts)
+825                                  0.52                     498                                                                             178                          312                               500          735
+                                                                                                                                                  183                                                                            730
+                                                                                                                                   0.25                                                            1000 1125
+                                                                                                                                                       185                      313
+                                                                                                                                                            187
+994                                  0.74                     735                                                                                           188                      314
+
+1163                                 1.01                     1017                                                                                               189                      314
+                                                                                                                                                                      190
+
+                                                                                                                                   0.00
+
+Note: Watts is for the entire unit.                                                                                                      375  500                625       750            875                             1250 1375 1500 1625
+
+Note: Airflow performance includes effect of clean, standard filter                                                                                                                    Airflow (cfm)
+supplied with unit.                                                                                                                           = Actual tested sample points
+
+ELECTRICAL DATA                                                            CORE PERFORMANCE
+
+                                      FLA   Min.                  Max.                                                                                      Airflow (CFM)
+                                      per    Cir.             Overcurrent
+HP Volts HZ     Phase                motor  Amps              Protection                                        Effectiveness (%)        300           600                 900            1,200     1,500
+                                                                                                                                   90%
+1.0 120 60      Single                8.0   18.0                 Device
+1.0 208-230 60  Single                                                                                                             70%
+                                      6.2   14.0                   20
+
+                                                                   15
+
+                                                                                                                                   50%
+
+                                                                                                                                   30%
+                                                                                                                                           At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+      Specifications may be subject to change without notice.
+44 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1.5XINH Energy Recovery Ventilator SEtCanMdoatrodr oOrpEtiConMotor Option
+
+                                                                                                                                                                                            42 5/8" Case                                           ABBREVIATIONS
+                                                                                                                                                                                                                                                   EA: Exhaust Air to outside
+                                                                                                                                                                        34 1/2"                                Patch Pan                           OA: Outside Air intake
+                                                                                                                                                                           Overall                             (Opening Used                       RA: Room Air to be exhausted
+                                                                                                                                                                                  32 5/8"                      for Alternative                     FA: Fresh Air to inside
+                                                                                                                                                                                      Case                     Unit Configurations)                INSTALLATION ORIENTATION
+                                                                                                                                                                                                               Typ.                                Unit may be installed in any
+                                                                                                                                                                                                                                                   orientation.
+                                                                                                                                                                                                                                                   NOTE
+                                                                                                                                                                                                                                                   1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                   DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                   NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                   2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                   TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                                                                   3. MIN. DUCT CLEARANCE
+                                                                                                                                                                                                                                                   FROM DAMPER BLADE WHEN FULLY
+                                                                                                                                                                                                                                                   OPENED TO BE 2". SMACNA RULES
+                                                                                                                                                                                                                                                   APPLY.
+
+                                                                                                                                                                                            TOP VIEW
+
+                                                                             EA Damper        18" X 18"                                                                 5" Damper           48 3/4"                                                20 1/8"Minimum
+                                                                                Location      Duct                                                                      Frames Typ.         Overall                                                Service Area
+                                                                                              Receiving                                                                                                                                            (Doors can be
+                                                                              (Optional)      Flange Typ.                                                                                                                                          Removed from Hinges.)
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 45           32"                                      EA                                                                                     OA                    49 3/8"Door
+                                                                                  6"                                                                                                                                                    Minimum ServiceSwing
+                                                                      52 3/4"                 Power Wiring
+                                                                         Case                 Inlet 7/8" dia.                                                                                                                               Area
+                                                                                                                                                                                                                                                                                                           53 5/8"
+                                                                                              Control Wiring                                                            FA                                     RA                                                                                              OverallDoor32"
+                                                                                              Inlet 7/8" dia.                                                                                                                        Swing         6"
+
+                                                                                              FA Damper                                                                 3 1/4"              Door-interlocked         Pressure             24 1/2"
+                                                                                              Location                                                                                      Disconnect Switch        Ports (4) Typ.    18" X 18"
+                                                                      6 3/8" Typ.             (Optional)                                                                                                       1 1/8" Typ.                                                  6 3/8" Typ.
+                                                                                                                                                                                                                                         Duct
+                                                                                                                                                                                                                                      Receiving    RIGHT VIEW
+                                                                                                                                                                                                                                     Flange Typ.
+                                                                                                                                                                                                                                                      UNIT MOUNTING & APPLICATION
+                                                                                   LEFT VIEW                                                                                                FRONT VIEW                                                Can be mounted in any orientation. RA/EA airstream
+                                                                                                                                                                                                                                                      can be switched with OA/FA airstream unless
+                                                                      DMroAAavIdawRilaeFbinLlle:OgaHsWsTEhyo1Cwp.On5eiNnX:dFIiNmUIGenHnUsiiRtonADdTraiImwOinNeg. nsion                                                                                certain options are selected. Duct configuration is
+                                                                      Version: MAY18                                                                                                                                                                  field convertible.
+
+                                                                                                                                                                                                               HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 1.5XINH Energy Recovery Ventilator
+                                                                 Standard with Bypass Economizer
+
+INDOOR UNIT                                                                SPECIFICATIONS                                                     Options:
+                                                                                                                                              Qty. 2, Variable Speed/ECM - Direct drive motors
+Download specification at:                                                 Ventilation Type:
+renewaire.com/specifications                                               Static plate, heat and humidity transfer                              (see HE1.5XINH EC Motor submittal) -
+                                                                                                                                                 1.0 HP 120V/1Ph/60HZ,
+                                                                           Typical Airflow Range:                                                 1.0 HP 208-230V/1Ph/60HZ
+                                                                           375–1,575 CFM                                                      Independent blower control
+                                                                                                                                              Fused disconnect
+                                                                           AHRI 1060 Certified Core:                                           Integrated programmable controls -
+                                                                           One L62-G5 and one L125-G5                                            enhanced, premium
+                                                                                                                                              Bypass economizer damper
+                                                                           Standard Features:                                                    (see bypass DIM drawing) -
+                                                                           Non-fused disconnect                                                  dry-bulb temperature controls (standard),
+                                                                           24 VAC transformer/relay package                                      enthalpy controls (option)
+                                                                           Cross-core differential pressure ports                             Class 1 low leakage motorized isolation dampers -
+                                                                                                                                                 FA, EA or both airstreams
+                                                                           Filters:                                                           Gravity backdraft dampers
+                                                                           Total Qty. 4, MERV 8: (2) 14" x 20" x 2" and                       Qty. 2, Factory mounted filter alarms -
+                                                                                                                                                 both airstreams
+                                                                              (2) 16" x 20" x 2"                                              Double wall construction
+                                                                                                                                              Exterior paint - white, custom colors
+                                                                           Unit Dimensions & Weight:
+                                                                           48 3/4" L x 34 1/2" W x 53 3/4" H                                  Accessories:
+                                                                           337-504 lbs., varies by option(s)                                  Filters - MERV 13, 2" (shipped loose)
+                                                                                                                                              Backdraft damper - OA or EA
+                                                                           Max. Shipping Dimensions & Weight (on pallet):                     Digital time clock - wall mount (TC7D-W),
+                                                                           70" L x 47" W x 53" H
+                                                                           571 lbs.                                                              in exterior enclosure (TC7D-E)
+                                                                                                                                              Carbon dioxide sensor/control -
+                                                                           Motor(s):
+                                                                           Qty. 2, 1.0 HP ea., Direct drive standard motorized                   wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                              IAQ sensor - wall mount (IAQ-W),
+                                                                              impeller packages
+                                                                                                                                                 duct mount (IAQ-D)
+                                                                                                                                              Motion occupancy sensor/control -
+
+                                                                                                                                                 ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                              Smoke Detector - duct mount (SD-D)
+                                                                                                                                              Electric duct heater - EK series (1–175 kW)
+                                                                                                                                              Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                 (50-400 MBH), installed downstream of any fans
+
+                       Thermal Performance Ratings G5 2015.2.xlsx                                             HE1.5X (IOM)
+AIRFLOW PERFORMANCE
+
+     Motor HP                                                                                 External Static Pressure (Inches Water Column)
+       Phase
+                             0.0                                  0.25                        0.50            0.75                1.00             1.25                                       1.50
+         1.0
+    Single Phase         1,575 CFM                            1,470 CFM     1,350 CFM                          1,225 CFM          1,090 CFM      950 CFM                                   795 CFM
+                         1,545 Watts                          1,525 Watts  1,500 Watts                        1,475 Watts         1,435 Watts  1,380 Watts                                1,300 Watts
+
+         1.0             1,675 CFM                            1,570 CFM    1,435 CFM                           1,280 CFM          1,115 CFM      940 CFM                                   760 CFM
+    Three Phase          1,410 Watts                          1,400 Watts  1,380 Watts                        1,340 Watts         1,280 Watts  1,210 Watts                                1,135 Watts
+
+Note: Watts is for the entire unit (2 motors).
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                            CORE PERFORMANCE
+
+HP  V  HZ         Phase   FLA         Min.                        Max.                                   Airflow (CFM)
+                          per          Cir.                   Overcurrent
+                         motor        Amps                    Protection   Effectiveness (%)        300  600  900          1,200  1,500
+                                                                                              90%
+                                                                 Device
+
+1.0 120 60 Single 6.5 14.6                                    20
+
+1.0 208-230 60 Single 3.3-3.4 7.7                             15                              70%
+
+1.0 277 60 Single 2.7 6.1                                     15                              50%
+
+1.0 208-230 60 Three 2.2-2.2 5.0                              15
+
+1.0 460 60 Three 1.1 2.5                                      15                              30%
+                                                                                                     At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+      Specifications may be subject to change without notice.
+46 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1.5XINH Energy Recovery Ventilator SWtaitnhdBayrdpawsisthEBcyopnaosms iEzecronOopmtiiozner(Standard & EC Motor)
+
+                                                                                                                                                          42 5/8" Case       1 1/4"                        ABBREVIATIONS
+                                                                                                                                                            13 7/8"                                        EA: Exhaust Air to outside
+                                                                       12" Round Bypass Duct Connection                                                                                                    OA: Outside Air intake
+                                                                      (Direct Mount to Damper, By Others)                                                                                                  RA: Room Air to be exhausted
+                                                                                                                                                                                                           FA: Fresh Air to inside
+                                                                                                   BP      Bypass                       36 3/8"                                                            BP: Bypass Air outlet
+                                                                          Face                             Damper                          Overall                                                         INSTALLATION ORIENTATION
+                                                                      Damper                                                                    31 7/8"                                                    Unit may be installed in any
+                                                                                                             RA                                     Case                                                   orientation.
+                                                                                 EA                                                                                                                        NOTE
+                                                                                                                                                                                                           1. UNLESS OTHERWISE SPECIFIED,
+                                                                      BYPASS AIRFLOW SCHEMATIC                                                            TOP VIEW                                         DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                           NEAREST EIGHTH OF AN INCH.
+                                                                                        TOP VIEW                                                                                                           2. SPECIFICATIONS MAY BE SUBJECT
+                                                                         (OA/FA Airstream Not Shown)                                                                                                       TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                           3. MIN. DUCT CLEARANCE
+                                                                                                       16" X 14" Isolation                                48 3/4" Overall                                  FROM DAMPER BLADE WHEN FULLY
+                                                                                                       Damper (Optional)                                                                                   OPENED TO BE 2". SMACNA RULES
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 47  6 1/4" Typ.                      Acts as Face                     5" Damper                            Pressure                      APPLY.
+                                                                      FA Damper                        Damper for                       Frames Typ.                          Ports (4) Typ.                4. UNITS WITH BYPASS WILL REQUIRE
+                                                                                                       Bypass Units                                                                                        ADDITIONAL SPACE FOR THE
+                                                                         Location                                                                                                                          CONNECTION OF THE BYPASS DUCT
+                                                                       (Optional)                                                                                                                          (BY OTHERS).
+                                                                                                                                                                                                           5. FOR INSTALLATION DETAILS, REFER
+                                                                          BP                                                                                                                               TO I&O MANUAL SUPPLEMENT FOR
+                                                                                                                                                                                                           BYPASS.
+                                                                                                                                                                                                          20 1/8" Minimum
+                                                                                                                                                                                                          Service Area
+                                                                                                                                                                                                          (Doors can be
+                                                                                                                                                                                                          Removed from Hinges.)
+
+                                                                                                                                                                                             Door
+                                                                                                                                                                                             Swing
+
+                                                                                                                                                                                             Door
+                                                                                                                                                                                             Swing
+                                                                      52 3/4" Case                         Power Wiring                 EA                                    OA
+                                                                           32"                             Inlet 7/8" dia.              FA
+                                                                                                                                6"Control Wiring                             12" Bypass
+                                                                                                                                                                         3 1/4"Inlet 7/8" dia.Location
+                                                                                                                                                                                                                                           49 3/8" Minimum
+                                                                                                                                                                                                                                               Service AreaRA
+                                                                                                                                                                                                                                                                                                 6"
+                                                                                                                                                                                                                                                                                                      10 5/8"
+                                                                                                                                                                                                                                                                                                           32"
+                                                                                                                                                                                                                                                                                                                 53 5/8" Overall
+                                                                      Plug Location                                                                       Door-interlocked   1 1/4" Duct     24 1/2"  6 3/8"
+                                                                           12" Bypass                                                                     Disconnect Switch  Receiving                  Typ.
+                                                                             Damper                                                                                          Flange Typ.
+
+                                                                       (Not Shown)                         18" X 18"                                      FRONT VIEW
+                                                                                                           Duct Receiving
+                                                                                       LEFT VIEW           Flange Typ.                                                                                RIGHT VIEW
+
+                                                                      MAIRoFdLeOlW: HCEO1N.5FXIGINURHA[TBIOyNpass]                                                                                    UNIT MOUNTING & APPLICATION
+                                                                      DAvarialabwle ains sghowTnyipn deim:enUsinonitdraDwiinmg. ension
+                                                                      Version: MAY18                                                                                                                  Can be mounted in any orientation. Airstreams
+                                                                                                                                                                                                      can not be switched.
+
+                                                                                                                                                                             HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 1.5XINH Energy Recovery Ventilator
+                                                                 EC Motoorr wOipthtioBnypass Economizer
+
+INDOOR UNIT                                                                SPECIFICATIONS
+
+Download specification at:                                                 Ventilation Type:                                                                                                          Options:
+renewaire.com/specifications                                               Static plate, heat and humidity transfer                                                                                   Fused disconnect
+                                                                           Typical Airflow Range: 375-1,575 CFM                                                                                        Integrated programmable controls -
+EC MOTOR OPTION OPERATING RANGE                                            AHRI 1060 Certified Core:
+                                                                           One L62-G5 and one L125-G5                                                                                                    enhanced, premium
+                                                                           Standard Features:                                                                                                         Bypass economizer damper
+                                                                           Non-fused disconnect
+                                                                           24 VAC transformer/relay package                                                                                              (see bypass DIM drawing) -
+                                                                           Cross-core differential pressure ports                                                                                        dry-bulb temperature controls (standard),
+                                                                           Filters:                                                                                                                      enthalpy controls (option)
+                                                                           Total qty. 4, MERV 8: (2) 14" x 20" x 2" and                                                                               Class 1 low leakage motorized isolation dampers -
+                                                                                                                                                                                                         FA, EA or both airstreams
+                                                                              (2) 16" x 20" x 2"                                                                                                      Gravity backdraft dampers
+                                                                           Unit Dimensions & Weight:                                                                                                  Qty. 2, Factory mounted filter alarms -
+                                                                           48 3/4" L x 34 1/2" W x 53 3/4" H                                                                                             both airstreams
+                                                                           336-504 lbs., varies by option(s)                                                                                          Double wall construction
+                                                                           Max. Shipping Dimensions & Weight (on pallet):                                                                             Exterior paint - white, custom colors
+                                                                           70" L x 47" W x 53" H
+                                                                           571 lbs.                                                                                                                   Accessories:
+                                                                           Motor(s):                                                                                                                  Filters - MERV 13, 2" (shipped loose)
+                                                                           Qty. 2, 1.0 HP ea., Direct drive EC motorized                                                                              Backdraft damper - OA or EA
+                                                                                                                                                                                                      Potentiometer speed control - remote installed
+                                                                              impeller packages                                                                                                       Digital time clock - wall mount (TC7D-W),
+
+                                                                                                                       HE1.5X-IN ECM                                                                     in exterior enclosure (TC7D-E)
+                                                                                                                                                                                                      Carbon dioxide sensor/control -
+
+                                                                                                                                                                                                         wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                                                                                      IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                                                                         duct mount (IAQ-D)
+                                                                                                                                                                                                      Motion occupancy sensor/control -
+
+                                                                                                                                                                                                         ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                                                                                      Smoke Detector - duct mount (SD-D)
+                                                                                                                                                                                                      Electric duct heater - EK series (1–175 kW)
+                                                                                                                                                                                                      Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                                                                         (50-400 MBH), installed downstream of any fans
+
+                                                                                                      1.75
+
+                HE1.5XINH EC MOTOR
+
+         Sample Points Depicted in Larger Dots
+
+                External Static                                                                                                    1.50                                                       965
+                   Pressure
+    Airflow                                   Unit Power                                                                                                                                                          1006
+    (CFM)       (Inches Water               Consumption                                                                                                                         698
+                   Column)
+                                               (Watts)                                                                             1.25
+
+    630                              0.07                     189          External Static Pressure (in. w.g.)
+
+    807         Therma0l.P12erformance Ratin31g4s G5 2015.2.xlsx 1.00                                                                                                      HE1.5X (IO72M7 )                            1017
+
+    1014                             0.20                     502
+
+    1222                             0.28                     735                                                                                                     475                        735                         1022
+
+                                                                                                                                   0.75
+
+    1430                             0.39                     1015                                                                                                         493                        739
+
+                                                                                                                                                                                     498                                              1021
+
+    513                              0.20                     185                                                                  0.50                296                                                           739
+                                                                                                                                                                                          501
+    656                              0.33                     310                                                                                           306
+
+                                                                                                                                                                 310                             502                                        1015
+                                                                                                                                                                                                       502                                         1006 (Watts)
+    825                              0.52                     498                                                                             178                          312                               500          735
+                                                                                                                                                  183                                                                            730
+                                                                                                                                   0.25                                                            1000 1125
+                                                                                                                                                       185                      313
+                                                                                                                                                            187
+    994                              0.74                     735                                                                                           188                      314
+
+    1163                             1.01                     1017                                                                                               189                      314
+                                                                                                                                                                      190
+
+                                                                                                                                   0.00
+
+Note: Watts is for the entire unit.                                                                                                      375  500                625       750            875                             1250 1375 1500 1625
+
+Note: Airflow performance includes effect of clean, standard filter                                                                                                                    Airflow (cfm)
+supplied with unit.                                                                                                                           = Actual tested sample points
+
+ELECTRICAL DATA                                                            CORE PERFORMANCE
+
+                                      FLA   Min.                  Max.                                                                                      Airflow (CFM)
+                                      per    Cir.             Overcurrent
+HP  Volts   HZ  Phase                motor  Amps              Protection                                        Effectiveness (%)        300           600                 900            1,200     1,500
+                                                                                                                                   90%
+                                                                 Device
+
+1.0 120 60 Single 8.0 18.0                                         20
+
+1.0 208-230 60 Single 6.2 14.0                                     15                                                              70%
+
+                                                                                                                                   50%
+
+                                                                                                                                   30%
+                                                                                                                                           At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+      Specifications may be subject to change without notice.
+48 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1.5XINH Energy Recovery Ventilator EWCithMBotyoprawssithEcBoynpoasmsizEecroOnopmtioizne(rStandard & EC Motor)
+
+                                                                                                                                                          42 5/8" Case       1 1/4"                        ABBREVIATIONS
+                                                                                                                                                            13 7/8"                                        EA: Exhaust Air to outside
+                                                                       12" Round Bypass Duct Connection                                                                                                    OA: Outside Air intake
+                                                                      (Direct Mount to Damper, By Others)                                                                                                  RA: Room Air to be exhausted
+                                                                                                                                                                                                           FA: Fresh Air to inside
+                                                                                                   BP      Bypass                       36 3/8"                                                            BP: Bypass Air outlet
+                                                                          Face                             Damper                          Overall                                                         INSTALLATION ORIENTATION
+                                                                      Damper                                                                    31 7/8"                                                    Unit may be installed in any
+                                                                                                             RA                                     Case                                                   orientation.
+                                                                                 EA                                                                                                                        NOTE
+                                                                                                                                                                                                           1. UNLESS OTHERWISE SPECIFIED,
+                                                                      BYPASS AIRFLOW SCHEMATIC                                                            TOP VIEW                                         DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                           NEAREST EIGHTH OF AN INCH.
+                                                                                        TOP VIEW                                                                                                           2. SPECIFICATIONS MAY BE SUBJECT
+                                                                         (OA/FA Airstream Not Shown)                                                                                                       TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                           3. MIN. DUCT CLEARANCE
+                                                                                                       16" X 14" Isolation                                48 3/4" Overall                                  FROM DAMPER BLADE WHEN FULLY
+                                                                                                       Damper (Optional)                                                                                   OPENED TO BE 2". SMACNA RULES
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 49  6 1/4" Typ.                      Acts as Face                     5" Damper                            Pressure                      APPLY.
+                                                                      FA Damper                        Damper for                       Frames Typ.                          Ports (4) Typ.                4. UNITS WITH BYPASS WILL REQUIRE
+                                                                                                       Bypass Units                                                                                        ADDITIONAL SPACE FOR THE
+                                                                         Location                                                                                                                          CONNECTION OF THE BYPASS DUCT
+                                                                       (Optional)                                                                                                                          (BY OTHERS).
+                                                                                                                                                                                                           5. FOR INSTALLATION DETAILS, REFER
+                                                                          BP                                                                                                                               TO I&O MANUAL SUPPLEMENT FOR
+                                                                                                                                                                                                           BYPASS.
+                                                                                                                                                                                                          20 1/8" Minimum
+                                                                                                                                                                                                          Service Area
+                                                                                                                                                                                                          (Doors can be
+                                                                                                                                                                                                          Removed from Hinges.)
+
+                                                                                                                                                                                             Door
+                                                                                                                                                                                             Swing
+
+                                                                                                                                                                                             Door
+                                                                                                                                                                                             Swing
+                                                                      52 3/4" Case                         Power Wiring                 EA                                    OA
+                                                                           32"                             Inlet 7/8" dia.              FA
+                                                                                                                                6"Control Wiring                             12" Bypass
+                                                                                                                                                                         3 1/4"Inlet 7/8" dia.Location
+                                                                                                                                                                                                                                           49 3/8" Minimum
+                                                                                                                                                                                                                                               Service AreaRA
+                                                                                                                                                                                                                                                                                                 6"
+                                                                                                                                                                                                                                                                                                      10 5/8"
+                                                                                                                                                                                                                                                                                                           32"
+                                                                                                                                                                                                                                                                                                                 53 5/8" Overall
+                                                                      Plug Location                                                                       Door-interlocked   1 1/4" Duct     24 1/2"  6 3/8"
+                                                                           12" Bypass                                                                     Disconnect Switch  Receiving                  Typ.
+                                                                             Damper                                                                                          Flange Typ.
+
+                                                                       (Not Shown)                         18" X 18"                                      FRONT VIEW
+                                                                                                           Duct Receiving
+                                                                                       LEFT VIEW           Flange Typ.                                                                                RIGHT VIEW
+
+                                                                      MAIRoFdLeOlW: HCEO1N.5FXIGINURHA[TBIOyNpass]                                                                                    UNIT MOUNTING & APPLICATION
+                                                                      DAvarialabwle ains sghowTnyipn deim:enUsinonitdraDwiinmg. ension
+                                                                      Version: MAY18                                                                                                                  Can be mounted in any orientation. Airstreams
+                                                                                                                                                                                                      can not be switched.
+
+                                                                                                                                                                             HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 1.5XINV Energy Recovery Ventilator
+                                                                 Standarrdd & Bypass Economizer Option
+
+INDOOR UNIT                                                                SPECIFICATIONS
+
+                                             HE1.5XINH shown               Ventilation Type:                                      Options:
+                                                                           Static plate, heat and humidity transfer               Qty. 2, Variable Speed/ECM - Direct drive motors
+Download specification at:
+renewaire.com/specifications                                               Typical Airflow Range: 375-1,575 CFM                       (see HE1.5XINV EC Motor submittal) -
+                                                                                                                                     1.0 HP 120V/1Ph/60HZ,
+                                                                           AHRI 1060 Certified Core:                                  1.0 HP 208-230V/1Ph/60HZ
+                                                                           One L62-G5 and one L125-G5                             Independent blower control
+                                                                                                                                  Fused disconnect
+                                                                           Standard Features:                                     Integrated programmable controls -
+                                                                           Non-fused disconnect                                      enhanced, premium
+                                                                           24 VAC transformer/relay package                       Bypass economizer damper
+                                                                           Cross-core differential pressure ports                    (see bypass DIM drawing) -
+                                                                                                                                     dry-bulb temperature controls (standard),
+                                                                           Filters:                                                  enthalpy controls (option)
+                                                                           Total qty. 4, MERV 8: (2) 14" x 20" x 2" and           Class 1 low leakage motorized isolation dampers -
+                                                                                                                                     FA, EA or both airstreams
+                                                                              (2) 16" x 20" x 2"                                  Gravity backdraft dampers
+                                                                                                                                  Qty. 2, Factory mounted filter alarms -
+                                                                           Unit Dimensions & Weight:                                 both airstreams
+                                                                           59 1/2" L x 34 1/2" W x 46 1/4" H                      Double wall construction
+                                                                           337-504 lbs., varies by option(s)                      Exterior paint - white, custom colors
+
+                                                                           Max. Shipping Dimensions & Weight (on pallet):         Accessories:
+                                                                           70" L x 47" W x 59" H                                  Filters - MERV 13, 2" (shipped loose)
+                                                                           571 lbs.                                               Backdraft damper - OA or EA
+                                                                                                                                  Digital time clock - wall mount (TC7D-W),
+                                                                           Motor(s):
+                                                                           Qty. 2, 1.0 HP ea., Direct drive standard motorized       in exterior enclosure (TC7D-E)
+                                                                                                                                  Carbon dioxide sensor/control -
+                                                                              impeller packages
+                                                                                                                                     wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                  IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                     duct mount (IAQ-D)
+                                                                                                                                  Motion occupancy sensor/control -
+
+                                                                                                                                     ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                  Smoke Detector - duct mount (SD-D)
+                                                                                                                                  Electric duct heater - EK series (1–175 kW)
+                                                                                                                                  Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                     (50-400 MBH), installed downstream of any fans
+
+                Thermal Performance Ratings G5 2015.2.xlsx                                                    HE1.5X (IOM)
+
+AIRFLOW PERFORMANCE
+
+ Motor HP                                                                                     External Static Pressure (Inches Water Column)
+   Phase
+                     0.0                                          0.25                        0.50            0.75                1.00             1.25                                        1.50
+     1.0
+Single Phase     1,575 CFM                                    1,470 CFM     1,350 CFM                          1,225 CFM          1,090 CFM      950 CFM                                    795 CFM
+                 1,545 Watts                                  1,525 Watts  1,500 Watts                        1,475 Watts         1,435 Watts  1,380 Watts                                 1,300 Watts
+
+     1.0         1,675 CFM                                    1,570 CFM    1,435 CFM                           1,280 CFM          1,115 CFM      940 CFM                                    760 CFM
+Three Phase      1,410 Watts                                  1,400 Watts  1,380 Watts                        1,340 Watts         1,280 Watts  1,210 Watts                                 1,135 Watts
+
+Note: Watts is for the entire unit (2 motors).
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                            CORE PERFORMANCE
+
+                                      FLA  Min.                   Max.                                   Airflow (CFM)
+HP Volts HZ Phase per                       Cir.              Overcurrent
+                                           Amps               Protection   Effectiveness (%)        300  600  900          1,200  1,500
+                                    motor                                                     90%
+                                           14.6                  Device
+1.0 120 60      Single 6.5                  7.7                                               70%
+1.0 208-230 60  Single 3.3-3.4              6.1                    20
+1.0 277 60      Single 2.7                  5.0                                               50%
+1.0 208-230 60  Three 2.2-2.2               2.5                    15
+1.0 460 60      Three 1.1                                                                     30%
+                                                                   15                                 At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+                                                                   15
+
+                                                                   15
+
+      Specifications may be subject to change without notice.
+50 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1.5XINV Energy Recovery Ventilator Standaarrdd or EC Motor Option
+
+                                                                                                                                                                                49 5/8" Case                   5" Damper                            ABBREVIATIONS
+                                                                                                                                                                                                               Frames Typ.                          EA: Exhaust Air to outside
+                                                                                                                                                                                                                                                    OA: Outside Air intake
+                                                                                   20 1/8" Minimum                                                                                                             32 5/8"                              RA: Room Air to be exhausted
+                                                                                        Service Area                                                                                                              Case                              FA: Fresh Air to inside
+                                                                                                                                                                                                                       34 1/2"                      INSTALLATION ORIENTATION
+                                                                                      (Doors can be                                                                                                                        Overall                  Unit may be installed in any
+                                                                                     Removed from                                                                                                                                                   orientation.
+                                                                                                                                                                                Door   Door           24 1/2"                                       NOTE
+                                                                                               Hinges.)                                                                         Swing  Swing                                                        1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                    DIMENSIONS ARE ROUNDED TO THE
+                                                                                            Patch Pan                                                                                                                                               NEAREST EIGHTH OF AN INCH.
+                                                                                     (Opening Used                                                                                                                                                  2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                    TO CHANGE WITHOUT NOTICE.
+                                                                                      for Alternative                                                                                                                                               3. MIN. DUCT CLEARANCE
+                                                                              Unit Configurations.)                                                                                                                                                 FROM DAMPER BLADE WHEN FULLY
+                                                                                                                                                                                                                                                    OPENED TO BE 2". SMACNA RULES
+                                                                                                     Typ.                                                                                                                                           APPLY.
+
+                                                                                                                                                                                49 1/2" Minimum
+                                                                                                                                                                                  Service Area
+
+                                                                                                                                                                                   TOP VIEW
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 51               18" X 18"                                                                                    59 1/2" Overall with                                    18" X 18"
+                                                                              Duct Receiving                                                                                      Damper Frames                                     Duct Receiving
+
+                                                                                 Flange Typ.                                                                                                                                          Flange Typ.
+
+                                                                                                       RA                                                                                                         OA                Power Wiring
+                                                                      46 1/4"                                                                                                                                   EA                     Inlet 7/8"
+                                                                         Overall                                                                                        FA                                                                                    24 5/8"
+                                                                                                                     24 5/8"                                                                                   Door-Interlocked     Control Wiring                    4 1/4"
+                                                                                                                                                                        3 1/4"                                 Disconnect Switch        Inlet 7/8"
+                                                                                                                          45 3/4"                                       1 1/8"                                                                  EA Damper           6 3/8"
+                                                                                                                             Case                                                                                                                   Location         Typ.
+                                                                      4 1/4"                                                                                                                                                                      (Optional)
+
+                                                                      6 3/8"  FA Damper                                                                                              Pressure
+                                                                       Typ.   Location                                                                                               Ports (4) Typ.
+                                                                              (Optional)
+                                                                                                                                                                                FRONT VIEW
+                                                                                         LEFT VIEW                                                                                                                                                  RIGHT VIEW
+
+                                                                      DMAAvrIoaaRildaFwbLleeiOnal:sWgsHhoCTEwyO1npi.Nn5edFXimI:GIeNUnUsnViRoniAtdTrDaIwOiimnNg. ension                                                                              UNIT MOUNTING & APPLICATION
+                                                                      Version: MAY18                                                                                                                                                                Can be mounted in any orientation. RA/EA airstream
+                                                                                                                                                                                                                                                    can be switched with OA/FA airstream unless
+                                                                                                                                                                                                                                                    certain options are selected. Duct configuration is
+                                                                                                                                                                                                                                                    field convertible.
+
+                                                                                                                                                                                                               HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 1.5XINV Energy Recovery Ventilator
+                                                                 EC Motor Option
+
+INDOOR UNIT                                                                SPECIFICATIONS
+
+                                              HE1.5XINH shown              Ventilation Type:                                                                                      Options:
+Download specification at:                                                 Static plate, heat and humidity transfer                                                               Fused disconnect
+renewaire.com/specifications                                               Typical Airflow Range: 375-1,575 CFM                                                                    Integrated programmable controls -
+                                                                           AHRI 1060 Certified Core:
+EC MOTOR OPTION OPERATING RANGE                                            One L62-G5 and one L125-G5                                                                                enhanced, premium
+                                                                           Standard Features:                                                                                     Bypass economizer damper
+                                                                           Non-fused disconnect
+                                                                           24 VAC transformer/relay package                                                                          (see bypass DIM drawing) -
+                                                                           Cross-core differential pressure ports                                                                    dry-bulb temperature controls (standard),
+                                                                           Filters:                                                                                                  enthalpy controls (option)
+                                                                           Total qty. 4, MERV 8: (2) 14" x 20" x 2" and                                                           Class 1 low leakage motorized isolation dampers -
+                                                                                                                                                                                     FA, EA or both airstreams
+                                                                              (2) 16" x 20" x 2"                                                                                  Gravity backdraft dampers
+                                                                           Unit Dimensions & Weight:                                                                              Qty. 2, Factory mounted filter alarms -
+                                                                           59 1/2" L x 34 1/2" W x 46 1/4" H                                                                         both airstreams
+                                                                           336-504 lbs., varies by option(s)                                                                      Double wall construction
+                                                                           Max. Shipping Dimensions & Weight (on pallet):                                                         Exterior paint - white, custom colors
+                                                                           70" L x 47" W x 59" H
+                                                                           571 lbs.                                                                                               Accessories:
+                                                                           Motor(s):                                                                                              Filters - MERV 13, 2" (shipped loose)
+                                                                           Qty. 2, 1.0 HP ea., Direct drive EC motorized                                                          Backdraft damper - OA or EA
+                                                                                                                                                                                  Potentiometer speed control - remote installed
+                                                                              impeller packages                                                                                   Digital time clock - wall mount (TC7D-W),
+
+                                                                                                                       HE1.5X-IN ECM                                                 in exterior enclosure (TC7D-E)
+                                                                                                                                                                                  Carbon dioxide sensor/control -
+
+                                                                                                                                                                                     wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                                                                  IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                                                     duct mount (IAQ-D)
+                                                                                                                                                                                  Motion occupancy sensor/control -
+
+                                                                                                                                                                                     ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                                                                  Smoke Detector - duct mount (SD-D)
+                                                                                                                                                                                  Electric duct heater - EK series (1–175 kW)
+                                                                                                                                                                                  Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                                                     (50-400 MBH), installed downstream of any fans
+
+                                                                                                         1.75
+
+                HE1.5XINV EC MOTOR
+
+         Sample Points Depicted in Larger Dots                                                                                                                             965
+
+                External Static                                                                                 1.50                                                                          1006
+                   Pressure                                                                                                                                  698
+    Airflow                        Unit Power                                                                    1.25
+    (CFM)       (Inches Water    Consumption
+                   Column)
+                                    (Watts)
+
+    630                0.07                                   189          External Static Pressure (in. w.g.)
+
+    807     Thermal P0e.1r2formance Rating3s14G5 2015.2.xlsx 1.00                                                                                                                                         1017
+
+                                                                                                                                                        HE1.5X (IO7M27 )
+
+    1014               0.20                                   502                                                                                                                                               1022
+
+                                                                                                                                                   475                      735
+
+    1222               0.28                                   735                                               0.75
+
+    1430               0.39                                   1015                                                                                      493                       739
+
+                                                                                                                                                                  498                                                 1021
+
+    513                0.20                                   185                                               0.50                296                                                           739
+                                                                                                                                                                       501
+                                                                                                                                         306
+
+    656                0.33                                   310                                                                             310                           502                                             1015
+                                                                                                                                                                                  502                                              1006 (Watts)
+    825                0.52                                   498                                                          178                          312                             500            735
+                                                                                                                               183                                                                            730
+                                                                                                                0.25                                                          1000 1125
+                                                                                                                                    185                      313
+                                                                                                                                         187
+                                                                                                                                         188                      314
+    994                0.74                                   735
+                                                                                                                                              189                      314
+                                                                                                                                                   190
+    1163               1.01                                   1017
+                                                                                                                0.00
+
+                                                                                                                      375  500                625       750            875                             1250 1375 1500 1625
+
+Note: Watts is for the entire unit.                                                                                                                                Airflow (cfm)
+Note: Airflow performance includes effect of clean, standard filter
+supplied with unit.                                                                                                        = Actual tested sample points
+
+                                                                           CORE PERFORMANCE
+
+ELECTRICAL DATA
+
+                        FLA      Min.                             Max.                                                                   Airflow (CFM)
+                        per       Cir.                        Overcurrent
+HP  Volts   HZ  Phase  motor     Amps                         Protection   Effectiveness (%)                          300           600            900            1,200           1,500
+                                                                                                                90%
+                                                                 Device
+
+1.0 120 60 Single 8.0 18.0                                         20                                           70%
+
+1.0 208-230 60 Single 6.2 14.0                                     15
+
+                                                                                                                50%
+
+                                                                                                                30%
+                                                                                                                       At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+      Specifications may be subject to change without notice.
+52 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1.5XINV Energy Recovery Ventilator SEtCanMdoatrodr oOrpEtiConMotor Option
+
+                                                                                                                                                                                49 5/8" Case                   5" Damper                            ABBREVIATIONS
+                                                                                                                                                                                                               Frames Typ.                          EA: Exhaust Air to outside
+                                                                                                                                                                                                                                                    OA: Outside Air intake
+                                                                                   20 1/8" Minimum                                                                                                             32 5/8"                              RA: Room Air to be exhausted
+                                                                                        Service Area                                                                                                              Case                              FA: Fresh Air to inside
+                                                                                                                                                                                                                       34 1/2"                      INSTALLATION ORIENTATION
+                                                                                      (Doors can be                                                                                                                        Overall                  Unit may be installed in any
+                                                                                     Removed from                                                                                                                                                   orientation.
+                                                                                                                                                                                Door   Door           24 1/2"                                       NOTE
+                                                                                               Hinges.)                                                                         Swing  Swing                                                        1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                    DIMENSIONS ARE ROUNDED TO THE
+                                                                                            Patch Pan                                                                                                                                               NEAREST EIGHTH OF AN INCH.
+                                                                                     (Opening Used                                                                                                                                                  2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                    TO CHANGE WITHOUT NOTICE.
+                                                                                      for Alternative                                                                                                                                               3. MIN. DUCT CLEARANCE
+                                                                              Unit Configurations.)                                                                                                                                                 FROM DAMPER BLADE WHEN FULLY
+                                                                                                                                                                                                                                                    OPENED TO BE 2". SMACNA RULES
+                                                                                                     Typ.                                                                                                                                           APPLY.
+
+                                                                                                                                                                                49 1/2" Minimum
+                                                                                                                                                                                  Service Area
+
+                                                                                                                                                                                   TOP VIEW
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 53               18" X 18"                                                                                    59 1/2" Overall with                                    18" X 18"
+                                                                              Duct Receiving                                                                                      Damper Frames                                     Duct Receiving
+
+                                                                                 Flange Typ.                                                                                                                                          Flange Typ.
+
+                                                                                                       RA                                                                                                         OA                Power Wiring
+                                                                      46 1/4"                                                                                                                                   EA                     Inlet 7/8"
+                                                                         Overall                                                                                        FA                                                                                    24 5/8"
+                                                                                                                     24 5/8"                                                                                   Door-Interlocked     Control Wiring                    4 1/4"
+                                                                                                                                                                        3 1/4"                                 Disconnect Switch        Inlet 7/8"
+                                                                                                                          45 3/4"                                       1 1/8"                                                                  EA Damper           6 3/8"
+                                                                                                                             Case                                                                                                                   Location         Typ.
+                                                                      4 1/4"                                                                                                                                                                      (Optional)
+
+                                                                      6 3/8"  FA Damper                                                                                              Pressure
+                                                                       Typ.   Location                                                                                               Ports (4) Typ.
+                                                                              (Optional)
+                                                                                                                                                                                FRONT VIEW
+                                                                                         LEFT VIEW                                                                                                                                                  RIGHT VIEW
+
+                                                                      MDAAvrIoaaRildaFwbLleeiOnal:sWgsHhoCTEwyO1npi.Nn5edFXimI:GIeNUnUsnViRoniAtdTrDaIwOiimnNg. ension                                                                              UNIT MOUNTING & APPLICATION
+                                                                      Version: MAY18                                                                                                                                                                Can be mounted in any orientation. RA/EA airstream
+                                                                                                                                                                                                                                                    can be switched with OA/FA airstream unless
+                                                                                                                                                                                                                                                    certain options are selected. Duct configuration is
+                                                                                                                                                                                                                                                    field convertible.
+
+                                                                                                                                                                                                               HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 1.5XINV Energy Recovery Ventilator
+                                                                 Standard with Bypass Economizer
+
+INDOOR UNIT                                                                SPECIFICATIONS
+
+                                             HE1.5XINH shown               Ventilation Type:                                      Options:
+                                                                           Static plate, heat and humidity transfer               Qty. 2, Variable Speed/ECM - Direct drive motors
+Download specification at:
+renewaire.com/specifications                                               Typical Airflow Range: 375-1,575 CFM                       (see HE1.5XINV EC Motor submittal) -
+                                                                                                                                     1.0 HP 120V/1Ph/60HZ,
+                                                                           AHRI 1060 Certified Core:                                  1.0 HP 208-230V/1Ph/60HZ
+                                                                           One L62-G5 and one L125-G5                             Independent blower control
+                                                                                                                                  Fused disconnect
+                                                                           Standard Features:                                     Integrated programmable controls -
+                                                                           Non-fused disconnect                                      enhanced, premium
+                                                                           24 VAC transformer/relay package                       Bypass economizer damper
+                                                                           Cross-core differential pressure ports                    (see bypass DIM drawing) -
+                                                                                                                                     dry-bulb temperature controls (standard),
+                                                                           Filters:                                                  enthalpy controls (option)
+                                                                           Total qty. 4, MERV 8: (2) 14" x 20" x 2" and           Class 1 low leakage motorized isolation dampers -
+                                                                                                                                     FA, EA or both airstreams
+                                                                              (2) 16" x 20" x 2"                                  Gravity backdraft dampers
+                                                                                                                                  Qty. 2, Factory mounted filter alarms -
+                                                                           Unit Dimensions & Weight:                                 both airstreams
+                                                                           59 1/2" L x 34 1/2" W x 46 1/4" H                      Double wall construction
+                                                                           337-504 lbs., varies by option(s)                      Exterior paint - white, custom colors
+
+                                                                           Max. Shipping Dimensions & Weight (on pallet):         Accessories:
+                                                                           70" L x 47" W x 59" H                                  Filters - MERV 13, 2" (shipped loose)
+                                                                           571 lbs.                                               Backdraft damper - OA or EA
+                                                                                                                                  Digital time clock - wall mount (TC7D-W),
+                                                                           Motor(s):
+                                                                           Qty. 2, 1.0 HP ea., Direct drive standard motorized       in exterior enclosure (TC7D-E)
+                                                                                                                                  Carbon dioxide sensor/control -
+                                                                              impeller packages
+                                                                                                                                     wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                  IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                     duct mount (IAQ-D)
+                                                                                                                                  Motion occupancy sensor/control -
+
+                                                                                                                                     ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                  Smoke Detector - duct mount (SD-D)
+                                                                                                                                  Electric duct heater - EK series (1–175 kW)
+                                                                                                                                  Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                     (50-400 MBH), installed downstream of any fans
+
+                Thermal Performance Ratings G5 2015.2.xlsx                                                    HE1.5X (IOM)
+
+AIRFLOW PERFORMANCE
+
+ Motor HP                                                                                     External Static Pressure (Inches Water Column)
+   Phase
+                     0.0                                          0.25                        0.50            0.75                1.00             1.25                                        1.50
+     1.0
+Single Phase     1,575 CFM                                    1,470 CFM     1,350 CFM                          1,225 CFM          1,090 CFM      950 CFM                                    795 CFM
+                 1,545 Watts                                  1,525 Watts  1,500 Watts                        1,475 Watts         1,435 Watts  1,380 Watts                                 1,300 Watts
+
+     1.0         1,675 CFM                                    1,570 CFM    1,435 CFM                           1,280 CFM          1,115 CFM      940 CFM                                    760 CFM
+Three Phase      1,410 Watts                                  1,400 Watts  1,380 Watts                        1,340 Watts         1,280 Watts  1,210 Watts                                 1,135 Watts
+
+Note: Watts is for the entire unit (2 motors).
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                            CORE PERFORMANCE
+
+                                      FLA  Min.                   Max.                                   Airflow (CFM)
+HP Volts HZ Phase per                       Cir.              Overcurrent
+                                           Amps               Protection   Effectiveness (%)        300  600  900          1,200  1,500
+                                    motor                                                     90%
+                                           14.6                  Device
+1.0 120 60      Single 6.5                  7.7                                               70%
+1.0 208-230 60  Single 3.3-3.4              6.1                    20
+1.0 277 60      Single 2.7                  5.0                                               50%
+1.0 208-230 60  Three 2.2-2.2               2.5                    15
+1.0 460 60      Three 1.1                                                                     30%
+                                                                   15                                 At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+                                                                   15
+
+                                                                   15
+
+      Specifications may be subject to change without notice.
+54 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1.5XINV Energy Recovery Ventilator W StaitnhdBayrdpawsisthEBcyopnaosms iEzecronOopmtiiozner(Standard & EC Motor)
+
+                                                                        Bypass  12" Round Bypass Duct Connection                          20 1/8" Minimum             49 5/8" Case                                         ABBREVIATIONS
+                                                                      Damper    (Direct Mount to Damper, By Others)                          Service Area                                                                  EA: Exhaust Air to outside
+                                                                                                                                                 (Doors can be          11 5/8"                                            OA: Outside Air intake
+                                                                                                  BP                                                Removed from                    12"                                    RA: Room Air to be exhausted
+                                                                                                                                                        Hinges.)                                                           FA: Fresh Air to inside
+                                                                      RA                                                    OA                                                                      31 7/8"                BP: Bypass Air outlet
+                                                                                                                                                             15 1/4"                                   Case                INSTALLATION ORIENTATION
+                                                                      FA                                                            EA                                                                      34 1/2"        Unit may be installed in any
+                                                                                                                                                                                                               Overall     orientation.
+                                                                                                                                                                                                                           NOTE
+                                                                                                                             Face Damper                              Door   Door          24 1/2"  Patch Pan              1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                      Swing  Swing                  (Opening Used          DIMENSIONS ARE ROUNDED TO THE
+                                                                      BYPASS AIRFLOW SCHEMATIC                                                                                                      for Alternative        NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                    Unit Configurations.)  2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                          FRONT VIEW                                                                                                Typ.                   TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                                           3. MIN. DUCT CLEARANCE
+                                                                                                                                          Plug Location               49 1/2" Minimum                                      FROM DAMPER BLADE WHEN FULLY
+                                                                                                                                               12" Bypass               Service Area                                       OPENED TO BE 2". SMACNA RULES
+                                                                                                                                                 Damper                                                                    APPLY.
+                                                                                                                                                                        TOP VIEW                                           4. UNITS WITH BYPASS WILL REQUIRE
+                                                                                                                                           (Not Shown)                                                                     ADDITIONAL SPACE FOR THE
+                                                                                                                                                                        59 1/2" Overall                                    CONNECTION OF THE BYPASS DUCT
+                                                                                                                                                                                                                           (BY OTHERS).
+                                                                                                                                                                                                                           5. FOR INSTALLATION DETAILS, REFER
+                                                                                                                                                                                                                           TO I&O MANUAL SUPPLEMENT FOR
+                                                                                                                                                                                                                           BYPASS.
+
+                                                                      6 1/4"    18" X 18"                                                                 BP2 7/8"                                                         16" X 14" Isolation
+                                                                        Typ.    Duct Receiving                                            RA                                                                            Damper (Optional)
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 55            Flange Typ.                                                                                                                                                                 6 1/4"
+                                                                                                                                                                                                                                Acts as Face                Typ.
+                                                                                                                                                                                                                                   Damper for
+                                                                      48 1/2" Overall                                                                                                               OA                            Bypass Units
+                                                                           45 3/4" Case
+                                                                                                             4 1/4"                       FA                                                                            Power Wiring                        4 1/4"
+                                                                                                                   24 5/8"                                                                                              Inlet 7/8"                                24 5/8"
+                                                                                                                                                                                                    EA
+
+                                                                                                                                                                                                                        Control Wiring
+                                                                                                                                                                                                                            Inlet 7/8"
+
+                                                                                                                       FA Damper          3 1/4"                           Pressure                 5" Damper                                   6 1/4"
+                                                                                                                       Location                                            Ports (4) Typ.           Frames Typ.
+                                                                                                                       (Optional)                                     1 1/4"
+
+                                                                                         LEFT VIEW                                                                                         Door-Interlocked
+                                                                                                                                                                                           Disconnect Switch
+                                                                      MAoIRdFLeOl:WHEC1O.N5FXIIGNUVRA[BTIyOpNass]
+                                                                      DAvraailawbleinasgshoTwynpinedi:meUnsniointdDrawiming.ension                                    FRONT VIEW                                                                RIGHT VIEW
+                                                                      Version: MAY18
+                                                                                                                                                                                                                                                UNIT MOUNTING & APPLICATION
+
+                                                                                                                                                                                                                                                Can be mounted in any orientation. Airstreams
+                                                                                                                                                                                                                                                can not be switched.
+
+                                                                                                                                                                                           HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 1.5XINV Energy Recovery Ventilator
+                                                                 EC Motoorr wOipthtioBnypass Economizer
+
+INDOOR UNIT                                                                SPECIFICATIONS
+
+                                              HE1.5XINH shown              Ventilation Type:                                                                                      Options:
+Download specification at:                                                 Static plate, heat and humidity transfer                                                               Fused disconnect
+renewaire.com/specifications                                               Typical Airflow Range: 375-1,575 CFM                                                                    Integrated programmable controls -
+                                                                           AHRI 1060 Certified Core:
+EC MOTOR OPTION OPERATING RANGE                                            One L62-G5 and one L125-G5                                                                                enhanced, premium
+                                                                           Standard Features:                                                                                     Bypass economizer damper
+                                                                           Non-fused disconnect
+                                                                           24 VAC transformer/relay package                                                                          (see bypass DIM drawing) -
+                                                                           Cross-core differential pressure ports                                                                    dry-bulb temperature controls (standard),
+                                                                           Filters:                                                                                                  enthalpy controls (option)
+                                                                           Total qty. 4, MERV 8: (2) 14" x 20" x 2" and                                                           Class 1 low leakage motorized isolation dampers -
+                                                                                                                                                                                     FA, EA or both airstreams
+                                                                              (2) 16" x 20" x 2"                                                                                  Gravity backdraft dampers
+                                                                           Unit Dimensions & Weight:                                                                              Qty. 2, Factory mounted filter alarms -
+                                                                           59 1/2" L x 34 1/2" W x 46 1/4" H                                                                         both airstreams
+                                                                           336-504 lbs., varies by option(s)                                                                      Double wall construction
+                                                                           Max. Shipping Dimensions & Weight (on pallet):                                                         Exterior paint - white, custom colors
+                                                                           70" L x 47" W x 59" H
+                                                                           571 lbs.                                                                                               Accessories:
+                                                                           Motor(s):                                                                                              Filters - MERV 13, 2" (shipped loose)
+                                                                           Qty. 2, 1.0 HP ea., Direct drive EC motorized                                                          Backdraft damper - OA or EA
+                                                                                                                                                                                  Potentiometer speed control - remote installed
+                                                                              impeller packages                                                                                   Digital time clock - wall mount (TC7D-W),
+
+                                                                                                                       HE1.5X-IN ECM                                                 in exterior enclosure (TC7D-E)
+                                                                                                                                                                                  Carbon dioxide sensor/control -
+
+                                                                                                                                                                                     wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                                                                  IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                                                     duct mount (IAQ-D)
+                                                                                                                                                                                  Motion occupancy sensor/control -
+
+                                                                                                                                                                                     ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                                                                  Smoke Detector - duct mount (SD-D)
+                                                                                                                                                                                  Electric duct heater - EK series (1–175 kW)
+                                                                                                                                                                                  Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                                                     (50-400 MBH), installed downstream of any fans
+
+                                                                                                         1.75
+
+                HE1.5XINV EC MOTOR
+
+         Sample Points Depicted in Larger Dots                                                                                                                             965
+
+                External Static                                                                                 1.50                                                                          1006
+                   Pressure                                                                                                                                  698
+    Airflow                        Unit Power                                                                    1.25
+    (CFM)       (Inches Water    Consumption
+                   Column)
+                                    (Watts)
+
+    630                0.07                                   189          External Static Pressure (in. w.g.)
+
+    807     Thermal P0e.1r2formance Rating3s14G5 2015.2.xlsx 1.00                                                                                                                                         1017
+
+                                                                                                                                                        HE1.5X (IO7M27 )
+
+    1014               0.20                                   502                                                                                                                                               1022
+
+                                                                                                                                                   475                      735
+
+    1222               0.28                                   735                                               0.75
+
+    1430               0.39                                   1015                                                                                      493                       739
+
+                                                                                                                                                                  498                                                 1021
+
+    513                0.20                                   185                                               0.50                296                                                           739
+                                                                                                                                                                       501
+                                                                                                                                         306
+
+    656                0.33                                   310                                                                             310                           502                                             1015
+                                                                                                                                                                                  502                                              1006 (Watts)
+    825                0.52                                   498                                                          178                          312                             500            735
+                                                                                                                               183                                                                            730
+                                                                                                                0.25                                                          1000 1125
+                                                                                                                                    185                      313
+                                                                                                                                         187
+                                                                                                                                         188                      314
+    994                0.74                                   735
+                                                                                                                                              189                      314
+                                                                                                                                                 190
+    1163               1.01                                   1017
+                                                                                                                0.00
+
+                                                                                                                      375  500                625       750            875                             1250 1375 1500 1625
+
+Note: Watts is for the entire unit.                                                                                                                                Airflow (cfm)
+Note: Airflow performance includes effect of clean, standard filter
+supplied with unit.                                                                                                        = Actual tested sample points
+
+                                                                           CORE PERFORMANCE
+
+ELECTRICAL DATA
+
+                        FLA      Min.                             Max.                                                                   Airflow (CFM)
+                        per       Cir.                        Overcurrent
+HP  Volts   HZ  Phase  motor     Amps                         Protection   Effectiveness (%)                          300           600            900            1,200           1,500
+                                                                                                                90%
+                                                                 Device
+
+1.0 120 60 Single 8.0 18.0                                         20                                           70%
+
+1.0 208-230 60 Single 6.2 14.0                                     15
+
+                                                                                                                50%
+
+                                                                                                                30%
+                                                                                                                       At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+      Specifications may be subject to change without notice.
+56 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE1.5XINV Energy Recovery Ventilator EWCithMBotyoprawssithEcBoynpoasmsizEecroOnopmtioizne(rStandard & EC Motor)
+
+                                                                        Bypass  12" Round Bypass Duct Connection                          20 1/8" Minimum             49 5/8" Case                                         ABBREVIATIONS
+                                                                      Damper    (Direct Mount to Damper, By Others)                          Service Area                                                                  EA: Exhaust Air to outside
+                                                                                                                                                 (Doors can be          11 5/8"                                            OA: Outside Air intake
+                                                                                                  BP                                                Removed from                    12"                                    RA: Room Air to be exhausted
+                                                                                                                                                        Hinges.)                                                           FA: Fresh Air to inside
+                                                                      RA                                                    OA                                                                      31 7/8"                BP: Bypass Air outlet
+                                                                                                                                                             15 1/4"                                   Case                INSTALLATION ORIENTATION
+                                                                      FA                                                            EA                                                                      34 1/2"        Unit may be installed in any
+                                                                                                                                                                                                               Overall     orientation.
+                                                                                                                                                                                                                           NOTE
+                                                                                                                             Face Damper                              Door   Door          24 1/2"  Patch Pan              1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                      Swing  Swing                  (Opening Used          DIMENSIONS ARE ROUNDED TO THE
+                                                                      BYPASS AIRFLOW SCHEMATIC                                                                                                      for Alternative        NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                    Unit Configurations.)  2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                          FRONT VIEW                                                                                                Typ.                   TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                                           3. MIN. DUCT CLEARANCE
+                                                                                                                                          Plug Location               49 1/2" Minimum                                      FROM DAMPER BLADE WHEN FULLY
+                                                                                                                                               12" Bypass               Service Area                                       OPENED TO BE 2". SMACNA RULES
+                                                                                                                                                 Damper                                                                    APPLY.
+                                                                                                                                                                        TOP VIEW                                           4. UNITS WITH BYPASS WILL REQUIRE
+                                                                                                                                           (Not Shown)                                                                     ADDITIONAL SPACE FOR THE
+                                                                                                                                                                        59 1/2" Overall                                    CONNECTION OF THE BYPASS DUCT
+                                                                                                                                                                                                                           (BY OTHERS).
+                                                                                                                                                                                                                           5. FOR INSTALLATION DETAILS, REFER
+                                                                                                                                                                                                                           TO I&O MANUAL SUPPLEMENT FOR
+                                                                                                                                                                                                                           BYPASS.
+
+                                                                      6 1/4"    18" X 18"                                                                 BP2 7/8"                                                         16" X 14" Isolation
+                                                                        Typ.    Duct Receiving                                            RA                                                                            Damper (Optional)
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 57            Flange Typ.                                                                                                                                                                 6 1/4"
+                                                                                                                                                                                                                                Acts as Face                Typ.
+                                                                                                                                                                                                                                   Damper for
+                                                                      48 1/2" Overall                                                                                                               OA                            Bypass Units
+                                                                           45 3/4" Case
+                                                                                                             4 1/4"                       FA                                                                            Power Wiring                        4 1/4"
+                                                                                                                   24 5/8"                                                                                              Inlet 7/8"                                24 5/8"
+                                                                                                                                                                                                    EA
+
+                                                                                                                                                                                                                        Control Wiring
+                                                                                                                                                                                                                            Inlet 7/8"
+
+                                                                                                                       FA Damper          3 1/4"                           Pressure                 5" Damper                                   6 1/4"
+                                                                                                                       Location                                            Ports (4) Typ.           Frames Typ.
+                                                                                                                       (Optional)                                     1 1/4"
+
+                                                                                         LEFT VIEW                                                                                         Door-Interlocked
+                                                                                                                                                                                           Disconnect Switch
+                                                                      MAoIRdFLeOl:WHEC1O.N5FXIIGNUVRA[BTIyOpNass]
+                                                                      DAvraailawbleinasgshoTwynpinedi:meUnsniointdDrawiming.ension                                    FRONT VIEW                                                                RIGHT VIEW
+                                                                      Version: MAY18
+                                                                                                                                                                                                                                                UNIT MOUNTING & APPLICATION
+
+                                                                                                                                                                                                                                                Can be mounted in any orientation. Airstreams
+                                                                                                                                                                                                                                                can not be switched.
+
+                                                                                                                                                                                           HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 1.5XRT                                                                 Energy Recovery Ventilator
+                                                                          Standard
+
+ROOFTOP UNIT                                                               SPECIFICATIONS                                                    Options:
+                                                                           Ventilation Type:                                                 Qty. 2, Variable Speed/ECM - Direct drive motors
+Download specification at:                                                 Static plate, heat and humidity transfer
+renewaire.com/specifications                                               Typical Airflow Range: 375-1,575 CFM                                  (see HE1.5XRT EC Motor submittal) -
+                                                                           AHRI 1060 Certified Core:                                             1.0 HP 120V/1Ph/60HZ,
+                                                                           One L62-G5 and one L125-G5                                           1.0 HP 208-230V/1Ph/60HZ
+                                                                           Standard Features:                                                Independent blower control
+                                                                           Non-fused disconnect                                              Onboard variable frequency drives (VFDs) -
+                                                                           24 VAC transformer/relay package                                     one or both airstreams
+                                                                           Cross-core differential pressure ports                            Fused disconnect
+                                                                           Filters:                                                          Integrated programmable controls -
+                                                                           Total qty. 4, MERV 8: (2) 14" x 20" x 2" and                         enhanced, premium
+                                                                                                                                             Class 1 low leakage motorized isolation dampers -
+                                                                              (2) 16" x 20" x 2"                                                FA, EA or both airstreams
+                                                                           Unit Dimensions & Weight:                                         Gravity backdraft dampers
+                                                                           86" L x 33 1/4" W x 56 3/4" H                                     Qty. 2, Factory mounted filter alarms -
+                                                                           387-548 lbs., varies by option(s)                                    both airstreams
+                                                                           Max. Shipping Dimensions & Weight (on pallet):                    Double wall construction
+                                                                           70" L x 47" W x 83" H                                             Exterior paint - white, custom colors
+                                                                           615 lbs.
+                                                                           Motor(s):                                                         Accessories:
+                                                                           Qty. 2, 1.0 HP ea., Direct drive standard motorized               Filters - MERV 13, 2" (shipped loose)
+                                                                                                                                             Backdraft damper - OA or EA
+                                                                              impeller packages                                              Roof curb - standard 14"
+                                                                                                                                             Curb wind clip
+                                                                          Thermal Performance Ratings G5 2015.2.xlsx                         Engineered combo curb for Carrier RTU
+                                                                                                                                             Engineered combo curb for Trane RTU
+                                                                                                                                             Digital time clock - wall mount (TC7D-W),
+
+                                                                                                                                                in exterior enclosure (TC7D-E)
+                                                                                                                                             Carbon dioxide sensor/control -
+
+                                                                                                                                                wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                             IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                duct mount (IAQ-D)
+                                                                                                                                             Motion occupancy sensor/control -
+
+                                                                                                                                                ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                             Smoke Detector - duct mount (SD-D)
+                                                                                                                                             Electric duct heater - EK series (1–175 kW);
+
+                                                                                                                                                designed for indoor ductwork installation only
+                                                                                                                                             Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                (50-400 MBH), insHtaEl1le.d5Xdo(wIOnMstr)eam of any fans
+
+AIRFLOW PERFORMANCE
+
+     Motor HP                                                                          External Static Pressure (Inches Water Column)
+       Phase
+                          0.0                                    0.25                  0.50             0.75                            1.00               1.25               1.50
+         1.0
+    Single Phase      1,535 CFM                               1390 CFM     1255 CFM                      1120 CFM     970 CFM                            815 CFM            640 CFM
+                      1,540 Watts                             1515 Watts   1485 Watts                   1445 Watts   1395 Watts                         1310 Watts         1195 Watts
+
+         1.0          1,630 CFM                               1485 CFM     1335 CFM                     1170 CFM      995 CFM                            810 CFM            615 CFM
+    Three Phase       1,440 Watts                             1435 Watts   1415 Watts                   1375 Watts   1325 Watts                         1260 Watts         1180 Watts
+
+Note: Watts is for the entire unit (2 motors).
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                      CORE PERFORMANCE
+
+                  Standard Electrical Specifications                         Optional Factory Installed                                             Airflow (CFM)
+                                                                           VFD Electrical Specifications
+
+                                        Min.                      Max.                                      Max.     Effectiveness (%)        300  600  900         1,200  1,500
+                                         Cir.                 Overcurrent                               Overcurrent                     90%
+HP  Volts         HZ  Phase     FLA     Amps                  Protection      FLA            Min. Cir.  Protection
+                             per motor                                     per motor          Amps
+                                                                 Device                                    Device
+                                                                                                                                        70%
+
+1.0 120 60 Single             6.5       14.6                  20
+
+1.0 208-230 60 Single 3.3-3.4 7.7                             15                                                                        50%
+
+1.0 277 60 Single             2.7       6.1                   15                                                                        30%
+
+1.0 208-230 60 Three 2.2-2.2 5.0                              15           2.2 - 2.2 5.4                15                                      At AHRI 1060 standard conditions.
+                                                                                                                                                See all AHRI certified ratings at www.ahrinet.org.
+1.0 460 60 Three              1.1       2.5                   15           1.1               2.8        15
+
+      Specifications may be subject to change without notice.
+58 RENEWAIRE.COM 1.800.627.4499
+HE1.5XRT (RTV/RTR) Energy Recovery Ventilator Standaarrdd or EC Motor Option
+
+                    CURB 1.5X                                                                                   28 1/4"                                                        45 3/4" Case                                                ABBREVIATIONS
+                                                                                                          2 1/8"   O.D.                                                        32 1/4"            RA                                       EA: Exhaust Air to outside
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 594 1/4"                                                                      1 1/8"                                            Opening                                  OA: Outside Air intake
+17 1/8" I.D.                                                                                                                                                                     11 1/8"          14" x 16"                                RA: Room Air to be exhausted
+                                                                                                                                                                                                                                           FA: Fresh Air to inside
+                                        17 1/8" I.D.                                                                                                                                                                                       RTV: Rooftop Vertical RA & FA
+                                                                                                                                                                                                                                           RTR: Rooftop Vertical RA Only
+24 1/2"           A                       A                                                                                    FA (RTV)                                                           15 3/8"                                  INSTALLATION ORIENTATION
+   I.D.                    FA   RA                                                                                              14" x 16"                                                              32 5/8"                             Unit must be installed in orientation
+                                                                                                                               Opening                                                                     Case                            shown.
+                                                                                                                                                                                                                                           NOTE:
+            1 7/8"  38 1/2" I.D.                                                                                                           10 1/8"                         Door      Door                    24 3/4"                       1. UNLESS OTHERWISE SPECIFIED,
+                    42 1/4" O.D.                                                                                               FA (RTV)                                    Swing     Swing                      Minimum                    DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                               Damper Location                                                                      Service                NEAREST EIGHTH OF AN INCH.
+                    TOP VIEW                                                                                                   (Optional)                                                                                                  2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                       Area                TO CHANGE WITHOUT NOTICE.
+
+CURB CROSS-SECTION A-A (TYP.)                                                                                                                                              55 5/8" Minimum                                                 33 1/4"
+                                                                                                                                                                             Service Area                                                 Overall
+         1 1/2" X 1/4"                  1 7/8"                                                                                                                                                                                             29 3/4"
+         Neoprene Gasket                                                                                                                                                       TOP VIEW                                                   Lift Lugs
+
+         3/4" X 3 1/2"                                                                                                                                                           86" Overall                                         RIGHT VIEW
+         Wooden Nailer                                                                                                                                                         42 7/8" Lift Lugs
+                                                                                                                                                                                                                                                UNIT MOUNTING & APPLICATION
+                                3"                                                                                                                                                                                                              Must be mounted as shown. Airstreams can not be
+                                                                                                                                                                                                                                                switched. Duct configuration is field convertible.
+                 SECTION A-A
+
+56 3/4"                         EA Damper                                                                                         5" Damper                                                                     OA
+   Overall                      Location                                                                                         Frames Typ.                                                      Pressure
+                                (Optional)                                                                                                                                                        Ports (4) Typ.
+        54"                                                                                                                                EA
+            Case                     FA (RTR)
+                                     18" X 18"                                                                                        E-Box
+                                     Duct Receiving                                                                            Disconnect
+                                     Flange
+                                                                                                                                      Switch
+
+                                        22 1/8"                                                                                               FA   RTR                                                                       1 7/8"
+                                           Wiring                                                                                                 ONLY
+
+                        3 5/8"                                                                                                 CL 5 5/8" Power In                              FA
+
+CL 26 1/8"          LEFT VIEW   5 7/8"  FA (RTR)                                                                               CL 2 1/2" Control In                             RTV  RA
+    Wiring                              Damper Location                                                                        (2) 7/8" holes for                              ONLY
+
+                                        (Optional)                                                                             wiring in bottom of
+
+                                                                                                                HERT except 6x 8x, LEER-TBox      HERT except 6x 8x, LERT
+
+                                                                                                                                                                           FRONT VIEW
+
+MoAdIReFlL: OHW E1C.5OXNRFTIVG/URRTARTION                                                                           RTV                                   RTR
+DraAvwailainblegasTsyhpowen:: Unit Dimension
+                                                                                                                EA             OA                 EA                       OA
+
+Version: MAY18                                                                                                                                        FA
+
+                                                                                                                    FA                                    RA
+                                                                                                                           RA
+
+                                                                                                                                                                                                  HE-SERIES
+                                                                                                                                                                                                                                                                                                                                     SPECIFICATIONS & DIMENSIONS
+
+                                                                                                          2 1/8"
+60 RENEWAIRE.COM 1.800.627.4499
+HE1.5XRT (RTH/RTF) Energy Recovery Ventilator Standaarrdd or EC Motor Option
+
+                    CURB 1.5X                                                       28 1/4"                                                       45 3/4" Case                                ABBREVIATIONS
+                                                                                       O.D.                                                        11 1/8"                                    EA: Exhaust Air to outside
+               4 1/4"                                                                                               1 1/8"                                                                    OA: Outside Air intake
+17 1/8" I.D.                            17 1/8" I.D.                                                                                                        15 3/8"                           RA: Room Air to be exhausted
+                                                                                                                                                                                              FA: Fresh Air to inside
+24 1/2"           A                       A                                                      FA (RTF)                                                                   32 5/8"           RTF: Rooftop Vertical FA Only
+   I.D.                    FA   RA                                                               14" x 16"                                                                     Case           RTH: Rooftop Horizontal RA & FA
+                                                                                                Opening                                                                                       INSTALLATION ORIENTATION
+                                                                                                                                                                                              Unit must be installed in orientation
+            1 7/8"  38 1/2" I.D.                                                                            10 1/8"                           Door                   Door   24 3/4"           shown.
+                    42 1/4" O.D.                                                                FA (RTF)                                      Swing                  Swing     Minimum        NOTE:
+                                                                                                Damper Location                                                                    Service    1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                (Optional)                                                                                    DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                      Area    NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                              2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                              TO CHANGE WITHOUT NOTICE.
+
+                    TOP VIEW
+
+CURB CROSS-SECTION A-A (TYP.)                                                                                                            55 5/8" Minimum
+                                                                                                                                           Service Area
+         1 1/2" X 1/4"                  1 7/8"
+         Neoprene Gasket                                                                                                                     TOP VIEW
+
+         3/4" X 3 1/2"
+         Wooden Nailer
+
+                              3"                                                                                                                    86" Overall                               33 1/4"
+                                                                                                                                                  42 7/8" Lift Lugs
+                    SECTION A-A                                                                                                                                                               Overall
+                                                                                                                                                                                              29 3/4"
+                                EA Damper
+                                Location                                                                                                                                                      Lift Lugs
+                                (Optional)
+56 3/4"                                                                                                     EA                                                                            OA                                       RA
+   Overall                          FA (RTH)                                                                                                                                                                                       18" X 18"
+                                    18" X 18"                                                          E-Box                                                                  RA                                                   Duct Receiving
+        54"                         Duct Receiving                                              Disconnect                                                                                                                         Flange
+            Case                    Flange                                                                                                                                  Pressure
+                                                                                                       Switch                                                               Ports (4) Typ.
+
+                                        22 1/8"                                                                   FA   RTH                                                                    1 7/8"
+                                           Wiring                                                                     ONLY                                                                                                     6"
+
+                        3 5/8"                                                                  CL 5 5/8" Power In                                FA
+
+CL 26 1/8"          LEFT VIEW   5 7/8"  FA (RTH)                                                CL 2 1/2" Control In                              RTF                                             6 3/8"
+    Wiring
+                                        Damper Location                                         (2) 7/8" holes for                                ONLY                                        RIGHT VIEW
+
+                                        (Optional)                                              wiring in bottom of                                                                                      UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                                         Must be mounted as shown. Airstreams can not be
+                                                                                    HERT except 6x 8x, LEER-TBox      HERTexcept 6x 8x, LERT                                                             switched. Duct configuration is field convertible.
+
+                                                                                                                                              FRONT VIEW
+
+DMroaAAvdIwaRielaFinblL:legOHasW TEsy1hpoC.w5eOnX::NRUFTnIHGit/UDRRTiAmFTeIOnNsion         RTH                                      RTF
+                                                                                                                      EA
+                                                                                    EA          OA                                            OA
+                                                                                       FA       RA                                            RA
+
+Version: MAY18                                                                                                              FA
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
+
+                                                                      FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 61
+SPECIFICATIONS & DIMENSIONS
+
+HE 1.5XRT                                                                  Energy Recovery Ventilator
+                                                                           EC Motor Option
+
+ROOFTOP UNIT                                                               SPECIFICATIONS
+
+Download specification at:                                                 Ventilation Type:                                                                                                     Options:
+renewaire.com/specifications                                               Static plate, heat and humidity transfer                                                                              Fused disconnect
+                                                                           Typical Airflow Range: 375-1,525 CFM                                                                                   Integrated programmable controls -
+EC MOTOR OPTION OPERATING RANGE                                            AHRI 1060 Certified Core:
+                                                                           One L62-G5 and one L125-G5                                                                                               enhanced, premium
+                                                                           Standard Features:                                                                                                    Class 1 low leakage motorized isolation dampers -
+                                                                           Non-fused disconnect
+                                                                           24 VAC transformer/relay package                                                                                         FA, EA or both airstreams
+                                                                           Cross-core differential pressure ports                                                                                Gravity backdraft dampers
+                                                                           Filters:                                                                                                              Qty. 2, Factory mounted filter alarms -
+                                                                           Total qty. 4, MERV 8: (2) 14" x 20" x 2" and
+                                                                                                                                                                                                    both airstreams
+                                                                              (2) 16" x 20" x 2"                                                                                                 Double wall construction
+                                                                           Unit Dimensions & Weight:                                                                                             Exterior paint - white, custom colors
+                                                                           86" L x 33 1/4" W x 56 3/4" H
+                                                                           386-548 lbs., varies by option(s)                                                                                     Accessories:
+                                                                           Max. Shipping Dimensions & Weight (on pallet):                                                                        Filters - MERV 13, 2" (shipped loose)
+                                                                           70" L x 47" W x 83" H                                                                                                 Backdraft damper - OA or EA
+                                                                           615 lbs.                                                                                                              Potentiometer speed control - remote installed
+                                                                           Motor(s):                                                                                                             Roof curb - standard 14"
+                                                                           Qty. 2, 1.0 HP ea., Direct drive EC motorized                                                                         Curb wind clip
+                                                                                                                                                                                                 Engineered combo curb for Carrier RTU
+                                                                              impeller packages                                                                                                  Engineered combo curb for Trane RTU
+                                                                                                                                                                                                 Digital time clock - wall mount (TC7D-W),
+                                                                                                                    HE1.5X-RT ECM
+                                                                                                                                                                                                    in exterior enclosure (TC7D-E)
+                                                                                                                                                                                                 Carbon dioxide sensor/control -
+
+                                                                                                                                                                                                    wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                                                                                 IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                                                                    duct mount (IAQ-D)
+                                                                                                                                                                                                 Motion occupancy sensor/control -
+
+                                                                                                                                                                                                    ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                                                                                 Smoke Detector - duct mount (SD-D)
+                                                                                                                                                                                                 Electric duct heater - EK series (1–175 kW);
+
+                                                                                                                                                                                                    designed for indoor ductwork installation only
+                                                                                                                                                                                                 Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                                                                    (50-400 MBH), installed downstream of any fans
+
+                                                                                              1.75
+
+        HE1.5XRT EC MOTOR
+
+     Sample Points Depicted in Larger Dots                                                                      1.50                                              907
+
+Airflow        External Static   Unit Power                                                                      1.25                                                                973
+(CFM)            Pressure      Consumption                                                                                                              658
+
+              (Inches Water       (Watts)                                                                                                                       HE1.5X (IOM) 1000
+                 Column)
+                                                                           External Static Pressure (in. w.g.)                                                    703
+593                     0.07                                  188   G5
+        Thermal Performance    Ratings                                  2015.2.xlsx
+                  0.12              313                                                                         1.00
+760
+
+955                     0.20                                  502                                                                                  451                      722                  1015
+
+1151                    0.29                                  739                                               0.75
+
+                                                                                                                                                        478                        733
+
+1347                    0.39                                  1021                                                                                           489                                             1022
+
+453                     0.20                                  182                                               0.50                    283                            497                  738
+                                                                                                                                              298
+
+                                                                                                                                                   304                        501                739               1021
+                                                                                                                                                                                                        735              1015 (Watts)
+577                     0.33                                  304                                                                  179                  309
+
+725                     0.51                                  489                                               0.25                    182                  312                   502
+                                                                                                                                             185                    313                  501
+                                                                                                                                                  187
+                                                                                                                                                        188
+874                     0.74                                  722                                                                                            189         314
+
+1026                    1.01                                  1000                                              0.00
+
+                                                                                                                                   375        500       625       750       875 1000 1125 1250 1375 1500 1625
+
+Note: Watts is for the entire unit.                                                                                                                                          Airflow (cfm)
+Note: Airflow performance includes effect of clean, standard filter
+supplied with unit.                                                                                                                     = Actual tested sample points
+
+                                                                           CORE PERFORMANCE
+
+ELECTRICAL DATA                                                                                                                                         Airflow (CFM)
+
+ HP Volts HZ Phase       FLA   Min.                               Max.                                          Effectiveness (%)        300       600            900              1,200      1,500
+ 1.0 120 60 Single       per    Cir.                          Overcurrent                                                          90%
+ 1.0 208-230 60 Single  motor  Amps                           Protection
+                                                                                                                                   70%
+                         8.0   18.0                              Device
+                                                                                                                                   50%
+                         6.2   14.0                                20
+
+                                                                   15
+
+                                                                                                                                   30%
+                                                                                                                                          At AHRI 1060 standard conditions. See all AHRI certified ratings at www.ahrinet.org.
+
+      Specifications may be subject to change without notice.
+62 RENEWAIRE.COM 1.800.627.4499
+HE1.5XRT (RTV/RTR) Energy Recovery Ventilator SEtCanMdoatrodr oOrpEtiConMotor Option
+
+                    CURB 1.5X                                                                                   28 1/4"                                                        45 3/4" Case                                                ABBREVIATIONS
+                                                                                                          2 1/8"   O.D.                                                        32 1/4"            RA                                       EA: Exhaust Air to outside
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 634 1/4"                                                                      1 1/8"                                            Opening                                  OA: Outside Air intake
+17 1/8" I.D.                                                                                                                                                                     11 1/8"          14" x 16"                                RA: Room Air to be exhausted
+                                                                                                                                                                                                                                           FA: Fresh Air to inside
+                                        17 1/8" I.D.                                                                                                                                                                                       RTV: Rooftop Vertical RA & FA
+                                                                                                                                                                                                                                           RTR: Rooftop Vertical RA Only
+24 1/2"           A                       A                                                                                    FA (RTV)                                                           15 3/8"                                  INSTALLATION ORIENTATION
+   I.D.                    FA   RA                                                                                              14" x 16"                                                              32 5/8"                             Unit must be installed in orientation
+                                                                                                                               Opening                                                                     Case                            shown.
+                                                                                                                                                                                                                                           NOTE:
+            1 7/8"  38 1/2" I.D.                                                                                                           10 1/8"                         Door      Door                    24 3/4"                       1. UNLESS OTHERWISE SPECIFIED,
+                    42 1/4" O.D.                                                                                               FA (RTV)                                    Swing     Swing                      Minimum                    DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                               Damper Location                                                                      Service                NEAREST EIGHTH OF AN INCH.
+                    TOP VIEW                                                                                                   (Optional)                                                                                                  2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                       Area                TO CHANGE WITHOUT NOTICE.
+
+CURB CROSS-SECTION A-A (TYP.)                                                                                                                                              55 5/8" Minimum                                                 33 1/4"
+                                                                                                                                                                             Service Area                                                 Overall
+         1 1/2" X 1/4"                  1 7/8"                                                                                                                                                                                             29 3/4"
+         Neoprene Gasket                                                                                                                                                       TOP VIEW                                                   Lift Lugs
+
+         3/4" X 3 1/2"                                                                                                                                                           86" Overall                                         RIGHT VIEW
+         Wooden Nailer                                                                                                                                                         42 7/8" Lift Lugs
+                                                                                                                                                                                                                                                UNIT MOUNTING & APPLICATION
+                                3"                                                                                                                                                                                                              Must be mounted as shown. Airstreams can not be
+                                                                                                                                                                                                                                                switched. Duct configuration is field convertible.
+                 SECTION A-A
+
+56 3/4"                         EA Damper                                                                                         5" Damper                                                                     OA
+   Overall                      Location                                                                                         Frames Typ.                                                      Pressure
+                                (Optional)                                                                                                                                                        Ports (4) Typ.
+        54"                                                                                                                                EA
+            Case                     FA (RTR)
+                                     18" X 18"                                                                                        E-Box
+                                     Duct Receiving                                                                            Disconnect
+                                     Flange
+                                                                                                                                      Switch
+
+                                        22 1/8"                                                                                               FA   RTR                                                                       1 7/8"
+                                           Wiring                                                                                                 ONLY
+
+                        3 5/8"                                                                                                 CL 5 5/8" Power In                              FA
+
+CL 26 1/8"          LEFT VIEW   5 7/8"  FA (RTR)                                                                               CL 2 1/2" Control In                             RTV  RA
+    Wiring                              Damper Location                                                                        (2) 7/8" holes for                              ONLY
+
+                                        (Optional)                                                                             wiring in bottom of
+
+                                                                                                                HERT except 6x 8x, LEER-TBox      HERT except 6x 8x, LERT
+
+                                                                                                                                                                           FRONT VIEW
+
+MoAdIReFlL: OHW E1C.5OXNRFTIVG/URRTARTION                                                                           RTV                                   RTR
+DraAvwailainblegasTsyhpowen:: Unit Dimension
+                                                                                                                EA             OA                 EA                       OA
+
+Version: MAY18                                                                                                                                        FA
+
+                                                                                                                    FA                                    RA
+                                                                                                                           RA
+
+                                                                                                                                                                                                  HE-SERIES
+                                                                                                                                                                                                                                                                                                                                     SPECIFICATIONS & DIMENSIONS
+
+                                                                                                          2 1/8"
+64 RENEWAIRE.COM 1.800.627.4499
+HE1.5XRT (RTH/RTF) Energy Recovery Ventilator SEtCanMdoatrodr oOrpEtiConMotor Option
+
+                    CURB 1.5X                                                       28 1/4"                                                       45 3/4" Case                                ABBREVIATIONS
+                                                                                       O.D.                                                        11 1/8"                                    EA: Exhaust Air to outside
+               4 1/4"                                                                                               1 1/8"                                                                    OA: Outside Air intake
+17 1/8" I.D.                            17 1/8" I.D.                                                                                                        15 3/8"                           RA: Room Air to be exhausted
+                                                                                                                                                                                              FA: Fresh Air to inside
+24 1/2"           A                       A                                                      FA (RTF)                                                                   32 5/8"           RTF: Rooftop Vertical FA Only
+   I.D.                    FA   RA                                                               14" x 16"                                                                     Case           RTH: Rooftop Horizontal RA & FA
+                                                                                                Opening                                                                                       INSTALLATION ORIENTATION
+                                                                                                                                                                                              Unit must be installed in orientation
+            1 7/8"  38 1/2" I.D.                                                                            10 1/8"                           Door                   Door   24 3/4"           shown.
+                    42 1/4" O.D.                                                                FA (RTF)                                      Swing                  Swing     Minimum        NOTE:
+                                                                                                Damper Location                                                                    Service    1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                (Optional)                                                                                    DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                      Area    NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                              2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                              TO CHANGE WITHOUT NOTICE.
+
+                    TOP VIEW
+
+CURB CROSS-SECTION A-A (TYP.)                                                                                                            55 5/8" Minimum
+                                                                                                                                           Service Area
+         1 1/2" X 1/4"                  1 7/8"
+         Neoprene Gasket                                                                                                                     TOP VIEW
+
+         3/4" X 3 1/2"
+         Wooden Nailer
+
+                              3"                                                                                                                    86" Overall                               33 1/4"
+                                                                                                                                                  42 7/8" Lift Lugs
+                    SECTION A-A                                                                                                                                                               Overall
+                                                                                                                                                                                              29 3/4"
+                                EA Damper
+                                Location                                                                                                                                                      Lift Lugs
+                                (Optional)
+56 3/4"                                                                                                     EA                                                                            OA                                       RA
+   Overall                          FA (RTH)                                                                                                                                                                                       18" X 18"
+                                    18" X 18"                                                          E-Box                                                                  RA                                                   Duct Receiving
+        54"                         Duct Receiving                                              Disconnect                                                                                                                         Flange
+            Case                    Flange                                                                                                                                  Pressure
+                                                                                                       Switch                                                               Ports (4) Typ.
+
+                                        22 1/8"                                                                   FA   RTH                                                                    1 7/8"
+                                           Wiring                                                                     ONLY                                                                                                     6"
+
+                        3 5/8"                                                                  CL 5 5/8" Power In                                FA
+
+CL 26 1/8"          LEFT VIEW   5 7/8"  FA (RTH)                                                CL 2 1/2" Control In                              RTF                                             6 3/8"
+    Wiring
+                                        Damper Location                                         (2) 7/8" holes for                                ONLY                                        RIGHT VIEW
+
+                                        (Optional)                                              wiring in bottom of                                                                                      UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                                         Must be mounted as shown. Airstreams can not be
+                                                                                    HERT except 6x 8x, LEER-TBox      HERTexcept 6x 8x, LERT                                                             switched. Duct configuration is field convertible.
+
+                                                                                                                                              FRONT VIEW
+
+DMroaAAvdIwaRielaFinblL:legOHasW TEsy1hpoC.w5eOnX::NRUFTnIHGit/UDRRTiAmFTeIOnNsion         RTH                                      RTF
+                                                                                                                      EA
+                                                                                    EA          OA                                            OA
+                                                                                       FA       RA                                            RA
+
+Version: MAY18                                                                                                              FA
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
+
+                                                                      FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 65
+SPECIFICATIONS & DIMENSIONS
+
+HE 2XINH                                                             Energy Recovery Ventilator
+                                                                     Standarrdd & Bypass Economizer Option
+
+INDOOR UNIT                                                          SPECIFICATIONS                                                          Options:
+                                                                                                                                             Onboard variable frequency drives (VFDs) -
+Download specification at:                                           Ventilation Type:
+renewaire.com/specifications                                         Static plate, heat and humidity transfer                                   one or both airstreams
+                                                                                                                                             Shaft grounding ring on motors with VFDs
+                                                                     Typical Airflow Range: 500-2,200 CFM                                     Fused disconnect
+                                                                                                                                             Integrated programmable controls -
+                                                                     AHRI 1060 Certified Core: Two L125-G5
+                                                                                                                                                enhanced, premium
+                                                                     Standard Features:                                                      Bypass economizer damper
+                                                                     TEFC Premium efficiency motors
+                                                                     Motor starters                                                             (see bypass DIM drawing) -
+                                                                     Non-fused disconnect                                                       dry-bulb temperature controls (standard),
+                                                                     24 VAC transformer/relay package                                           enthalpy controls (option)
+                                                                     Cross-core differential pressure ports                                  Class 1 low leakage motorized isolation dampers -
+                                                                                                                                                OA, RA or both airstreams
+                                                                     Filters:                                                                Qty. 2, Factory mounted filter alarms -
+                                                                     Total qty. 4, MERV 8: 20" x 20" x 2"                                       both airstreams
+                                                                                                                                             Double wall construction
+                                                                     Unit Dimensions & Weight:                                               Exterior paint - white, custom colors
+                                                                     64 1/2" L x 43" W x 35 1/2" H
+                                                                     406-619 lbs., varies by option(s)                                       Accessories:
+                                                                                                                                             Filters - MERV 13, 2" (shipped loose)
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                          Digital time clock - wall mount (TC7D-W),
+                                                                     70" L x 47" W x 40" H
+                                                                     714 lbs.                                                                    in exterior enclosure (TC7D-E)
+                                                                                                                                             Carbon dioxide sensor/control -
+                                                                     Motor(s):
+                                                                     Qty. 2, Belt drive blower/standard motor packages                          wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                             IAQ sensor - wall mount (IAQ-W),
+                                                                        with adjustable sheaves (see table below)
+                                                                                                                                                duct mount (IAQ-D)
+                                                                                                                                             Motion occupancy sensor/control -
+
+                                                                                                                                                ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                             Smoke Detector - duct mount (SD-D)
+                                                                                                                                             Electric duct heater - EK series (1–175 kW)
+                                                                                                                                             Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                (50-400 MBH), installed downstream of any fans
+
+AIRFLOW PERFORMANCE
+
+                  Sheave                                                               External Static Pressure (in. w.g.)
+                    Adj.
+Motor  Blower      Turns             0.00                     0.25Thermal Perfor0m.50ance Ratings G50.270515.2.xlsx                          1.00             12.2C5ores (IOM) 1.50
+ HP     RPM        Open       SCFM BHP                                                                                                                  SCFM BHP SCFM BHP
+                              1592 0.7                        SCFM BHP SCFM BHP SCFM BHP SCFM BHP
+ 1.5    1148         4        1809 1.0
+        1304                  2025 1.5                        1480 0.7 1320 0.6 1120 0.5                                                800        0.4
+ 2.0    1460         2        2130 1.6
+        1506                                                  1720 1.0 1600 0.9 1410 0.8 1250 0.7                                                       975   0.6      630                         0.4
+        1584         0
+        1661                                                  1950 1.4 1845 1.3 1715 1.2 1540 1.1                                                       1400 1.0 1165 0.8
+                     2
+                                                              2050 1.5 1955 1.4 1840 1.3 1735 1.2                                                       1585 1.0 1360 0.9
+                     1
+                                                              2170 1.8 2080 1.7 1970 1.5 1870 1.4                                                       1765 1.3 1565 1.1
+                     0
+                                                                                       2200 1.9 2100 1.8 2000 1.7                                       1900 1.5 1765 1.4
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.        Operation in this zone will likely exceed FLA limits.                   Operation in this zone outside of core airflow limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                      CORE PERFORMANCE
+                     Standard Electrical Specifications
+                                                                                        Optional Factory Installed                                      Airflow (CFM)
+                                                                                       VFD Electrical Specifications
+
+                             FLA     Min. Cir.                    Max.        FLA      Min. Cir.      Max.                                   500        1000  1500          2000
+                          per motor   Amps                    Overcurrent  per motor    Amps      Overcurrent                           90%
+HP     Volts  HZ  Phase                                       Protection                          Protection         Effectiveness (%)
+
+                                                                 Device                              Device
+
+1.5 120 60 Single 15.2               34.2                          45                                                                   70%
+
+     208-230 60 Single 8.2-7.6 18.5                                25      4.6-4.8 20.6           25                                    50%
+                                                                   15
+1.5  208-230  60  Three   4.6-4.8    10.8                          15      4.6-4.8 11.9           15
+       460    60  Three     2.4      5.4                           15
+                                                                           2.4         5.9        15
+                                                                   60
+       575 60 Three 1.8              4.1                                   1.8         4.5        15                                    30%
+                                                                   35
+2.0 120 60 Single 20.0               45.0                          20                                                                           At AHRI 1060 standard conditions.
+                                                                   15                                                                           See all AHRI certified ratings at www.ahrinet.org.
+     208-230 60 Single 10.8-10.0 24.3                              15      6.6-5.8 28.3           30
+
+2.0  208-230  60  Three   6.6-5.8    14.9                                  6.6-5.8 16.3           20
+       460    60  Three     2.9      6.5
+                                                                           2.9         7.2        15
+
+       575 60 Three 2.4              5.4                                   2.4         5.9        15
+
+      Specifications may be subject to change without notice.
+66 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE2XINH Energy Recovery Ventilator Standard
+
+                                                                                                                                                                                                              
+                                                                                                                                                                                                                 
+                                                                                                                                                                                                                                 
+                                                                                                                                                                                                                  
+                                                                                                                                                                                                                     
+                                                                                                                                                                                                                                 
+                                                                                                                                                                                                                             
+                                                                                                                                                                                                                            
+                                                                                                                                                                                                                                 
+                                                                                                                                                                                                                  
+                                                                                                                                                                                                                     
+                                                                                                                                                                                                                                 
+                                                                                                                                                                                                                         
+                                                                                                                                                                                                                                 
+                                                                                                                                                                                                              
+                                                                                                                                                                                                                 
+                                                                                                                                                                                                                                 
+                                                                                                                                                                                                                                 
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 67                                                                                                                                         
+                                                                                                                                                                                                  
+                                                                                                                                                                                                                       
+                                                                                                                                                                                                                          
+                                                                                                                                                                                                                                                        
+                                                                                                                                 
+
+                                                                                                                                                                                                        
+                                                                                                                                                                                                              
+                                                                                                                                                                                                                                                                          
+                                                                                                                                                                                                                                                                                        
+                                                                                                                                      
+                                                                                                                                            
+                                                                                                                                                                             
+                                                                                                                                                          
+                                                                                                                                                                                                                           
+                                                                                                                                                                                                                           
+                                                                                                                                                                                                                                        
+                                                                                                                                                                                                                                        
+                                                                                                                                                                                                                                    
+                                                                                                
+                                                                                                                                                                                                                                 UNIT MOUNTING & APPLICATION
+                                                                           AIRFLOW CONFIGURATION
+                                                                                                                                                                                                                                 Must be mounted as shown. RA/EA airstream can
+                                                                      Availableasshown in dimension drawing.                                                                                                       be switched with OA/FA airstream unless certain
+                                                                                                                                                                                                     options are selected.
+                                                                      
+
+                                                                                                                                                                                   HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 2XINH                                                             Energy Recovery Ventilator
+                                                                     Standard with Bypass Economizer
+
+INDOOR UNIT                                                          SPECIFICATIONS                                                          Options:
+                                                                                                                                             Onboard variable frequency drives (VFDs) -
+Download specification at:                                           Ventilation Type:
+renewaire.com/specifications                                         Static plate, heat and humidity transfer                                   one or both airstreams
+                                                                                                                                             Shaft grounding ring on motors with VFDs
+                                                                     Typical Airflow Range: 500-2,200 CFM                                     Fused disconnect
+                                                                                                                                             Integrated programmable controls -
+                                                                     AHRI 1060 Certified Core: Two L125-G5
+                                                                                                                                                enhanced, premium
+                                                                     Standard Features:                                                      Bypass economizer damper
+                                                                     TEFC Premium efficiency motors
+                                                                     Motor starters                                                             (see bypass DIM drawing) -
+                                                                     Non-fused disconnect                                                       dry-bulb temperature controls (standard),
+                                                                     24 VAC transformer/relay package                                           enthalpy controls (option)
+                                                                     Cross-core differential pressure ports                                  Class 1 low leakage motorized isolation dampers -
+                                                                                                                                                OA, RA or both airstreams
+                                                                     Filters:                                                                Qty. 2, Factory mounted filter alarms -
+                                                                     Total qty. 4, MERV 8: 20" x 20" x 2"                                       both airstreams
+                                                                                                                                             Double wall construction
+                                                                     Unit Dimensions & Weight:                                               Exterior paint - white, custom colors
+                                                                     64 1/2" L x 43" W x 35 1/2" H
+                                                                     406-619 lbs., varies by option(s)                                       Accessories:
+                                                                                                                                             Filters - MERV 13, 2" (shipped loose)
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                          Digital time clock - wall mount (TC7D-W),
+                                                                     70" L x 47" W x 40" H
+                                                                     714 lbs.                                                                    in exterior enclosure (TC7D-E)
+                                                                                                                                             Carbon dioxide sensor/control -
+                                                                     Motor(s):
+                                                                     Qty. 2, Belt drive blower/standard motor packages                          wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                             IAQ sensor - wall mount (IAQ-W),
+                                                                        with adjustable sheaves (see table below)
+                                                                                                                                                duct mount (IAQ-D)
+                                                                                                                                             Motion occupancy sensor/control -
+
+                                                                                                                                                ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                             Smoke Detector - duct mount (SD-D)
+                                                                                                                                             Electric duct heater - EK series (1–175 kW)
+                                                                                                                                             Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                (50-400 MBH), installed downstream of any fans
+
+AIRFLOW PERFORMANCE
+
+                  Sheave                                                               External Static Pressure (in. w.g.)
+                    Adj.
+Motor  Blower      Turns             0.00                     0.25Thermal Perfor0m.50ance Ratings G50.270515.2.xlsx                          1.00             12.2C5ores (IOM) 1.50
+ HP     RPM        Open       SCFM BHP                                                                                                                  SCFM BHP SCFM BHP
+                              1592 0.7                        SCFM BHP SCFM BHP SCFM BHP SCFM BHP
+ 1.5    1148         4        1809 1.0
+        1304                  2025 1.5                        1480 0.7 1320 0.6 1120 0.5                                                800        0.4
+ 2.0    1460         2        2130 1.6
+        1506                                                  1720 1.0 1600 0.9 1410 0.8 1250 0.7                                                       975   0.6      630                         0.4
+        1584         0
+        1661                                                  1950 1.4 1845 1.3 1715 1.2 1540 1.1                                                       1400 1.0 1165 0.8
+                     2
+                                                              2050 1.5 1955 1.4 1840 1.3 1735 1.2                                                       1585 1.0 1360 0.9
+                     1
+                                                              2170 1.8 2080 1.7 1970 1.5 1870 1.4                                                       1765 1.3 1565 1.1
+                     0
+                                                                                       2200 1.9 2100 1.8 2000 1.7                                       1900 1.5 1765 1.4
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.        Operation in this zone will likely exceed FLA limits.                   Operation in this zone outside of core airflow limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                      CORE PERFORMANCE
+                     Standard Electrical Specifications
+                                                                                        Optional Factory Installed                                      Airflow (CFM)
+                                                                                       VFD Electrical Specifications
+
+                             FLA     Min. Cir.                    Max.        FLA      Min. Cir.      Max.                                   500        1000  1500          2000
+                          per motor   Amps                    Overcurrent  per motor    Amps      Overcurrent                           90%
+HP     Volts  HZ  Phase                                       Protection                          Protection         Effectiveness (%)
+
+                                                                 Device                              Device
+
+1.5 120 60 Single 15.2               34.2                          45                                                                   70%
+
+     208-230 60 Single 8.2-7.6 18.5                                25      4.6-4.8 20.6           25                                    50%
+                                                                   15
+1.5  208-230  60  Three   4.6-4.8    10.8                          15      4.6-4.8 11.9           15
+       460    60  Three     2.4      5.4                           15
+                                                                           2.4         5.9        15
+                                                                   60
+       575 60 Three 1.8              4.1                                   1.8         4.5        15                                    30%
+                                                                   35
+2.0 120 60 Single 20.0               45.0                          20                                                                           At AHRI 1060 standard conditions.
+                                                                   15                                                                           See all AHRI certified ratings at www.ahrinet.org.
+     208-230 60 Single 10.8-10.0 24.3                              15      6.6-5.8 28.3           30
+
+2.0  208-230  60  Three   6.6-5.8    14.9                                  6.6-5.8 16.3           20
+       460    60  Three     2.9      6.5
+                                                                           2.9         7.2        15
+
+       575 60 Three 2.4              5.4                                   2.4         5.9        15
+
+      Specifications may be subject to change without notice.
+68 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE2XINH Energy Recovery Ventilator Standard with Bypass Economizer
+
+                                                                                                                                                                                                           
+                                                                                                                                                                                                                                  
+                                                                                                                                                                                                                                                 
+                                                                                                                                                                                                                                       
+                                                                                                                                                                                                                                                 
+                                                                                                                                                                                                                
+                                                                                                                                                                                                              
+                                                                                                                                                                                                                              
+                                                                                                                                                                                                                         
+                                                                                                                                                                                                                                                 
+                                                                                                                                                                                                                                           
+                                                                                                                                                                                                                                                 
+                                                                                                                                                                                                                              
+                                                                                                                                                                                                                                     
+                                                                                                                                                                                                                                         
+                                                                                                                                                                                                                                            
+                                                                                                                                                                                                                                      
+                                                                                                                                                                                                                                  
+                                                                                                                                                                                                             
+                                                                                                                                                                                                                                                 
+                                                                                                                                                                                                                               
+                                                                                                                                                                                                                                                 
+                                                                                                                                                                                                                                                 
+                                                                                                                                                                                                                                                 
+                                                                                                                                                                                                                                                 
+                                                                                                                                                                                                                                                 
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 69                                                                                                                                                            
+                                                                                                                                                                                                                       
+                                                                                                                                                                                                                          
+                                                                                                                                                                                         
+                                                                                                                                                                                                                                                                      
+                                                                                                                                                              
+                                                                      
+
+                                                                                                                                                                                                                
+                                                                                                                                                                                                                              
+                                                                                                                                                                                                                            
+                                                                                                                                                                                                                                                                                              
+                                                                                                                                                                                                                                                                                                         
+                                                                                                                                                           
+                                                                                                                                                                                                         
+                                                                                                                                                                                                                     
+                                                                                                                                                                                                                                                         
+                                                                                                                                                                                                                                                  
+                                                                                                                                                                                            
+                                                                                                                                                                                                                         
+                                                                      AIRFLOW CONFIGURATION
+                                                                      Availableasshownindimensiondrawing.                                                       
+                                                                      
+                                                                                                                                                                                                                                                                       UNIT MOUNTING & APPLICATION
+
+                                                                                                                                                                                                                                                                       Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                                                                                                       be switched.
+
+                                                                                                                                                                                                                     HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 2XINV                                                             Energy Recovery Ventilator
+                                                                     Standarrdd & Bypass Economizer Option
+INDOOR UNIT
+                                                                     SPECIFICATIONS                                                          Options:
+Download specification at:                                                                                                                   Onboard variable frequency drives (VFDs) -
+renewaire.com/specifications                                         Ventilation Type:
+                                                                     Static plate, heat and humidity transfer                                   one or both airstreams
+                                                                                                                                             Shaft grounding ring on motors with VFDs
+                                                                     Typical Airflow Range: 500-2,200 CFM                                     Fused disconnect
+                                                                                                                                             Integrated programmable controls -
+                                                                     AHRI 1060 Certified Core: Two L125-G5
+                                                                                                                                                enhanced, premium
+                                                                     Standard Features:                                                      Bypass economizer damper
+                                                                     TEFC Premium efficiency motors
+                                                                     Motor starters                                                             (see bypass DIM drawing) -
+                                                                     Non-fused disconnect                                                       dry-bulb temperature controls (standard),
+                                                                     24 VAC transformer/relay package                                           enthalpy controls (option)
+                                                                     Cross-core differential pressure ports                                  Class 1 low leakage motorized isolation dampers -
+                                                                                                                                                OA, RA or both airstreams
+                                                                     Filters:                                                                Qty. 2, Factory mounted filter alarms -
+                                                                     Total qty. 4, MERV 8: 20" x 20" x 2"                                       both airstreams
+                                                                                                                                             Double wall construction
+                                                                     Unit Dimensions & Weight:                                               Exterior paint - white, custom colors
+                                                                     50 1/2" L x 42" W x 52 1/2" H
+                                                                     363-583 lbs., varies by option(s)                                       Accessories:
+                                                                                                                                             Filters - MERV 13, 2" (shipped loose)
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                          Digital time clock - wall mount (TC7D-W),
+                                                                     70" L x 47" W x 57" H
+                                                                     678 lbs.                                                                   in exterior enclosure (TC7D-E)
+                                                                                                                                             Carbon dioxide sensor/control -
+                                                                     Motor(s):
+                                                                     Qty. 2, Belt drive blower/standard motor packages                          wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                             IAQ sensor - wall mount (IAQ-W),
+                                                                        with adjustable sheaves (see table below)
+                                                                                                                                                duct mount (IAQ-D)
+                                                                                                                                             Motion occupancy sensor/control -
+
+                                                                                                                                                ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                             Smoke Detector - duct mount (SD-D)
+                                                                                                                                             Electric duct heater - EK series (1–175 kW)
+                                                                                                                                             Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                (50-400 MBH), installed downstream of any fans
+
+AIRFLOW PERFORMANCE
+
+                  Sheave                                                                     External Static Pressure (in. w.g.)
+                    Adj.
+Motor  Blower      Turns         0.00                   0.25                           0.50           0.75                                   1.00             1.25             1.50
+ HP     RPM        Open   SCFM BHP                                   Thermal Performance Ratings G5 2015.2.xlsx                                               2 Cores (IOM)
+                          1735 0.8                      SCFM BHP SCFM BHP SCFM BHP SCFM BHP                                                             SCFM BHP SCFM BHP
+ 1.5    1146         4    1975 1.1
+        1302                                            1670 0.7 1520 0.7 1205 0.5                                                      900        0.4
+ 2.0    1458         2
+        1503                                            1925 1.1 1835 1.0 1615 0.9 1340 0.8                                                             1080 0.6          670                      0.4
+        1581         0
+        1658                                                                           2100 1.5 1970 1.4 1755 1.3                                       1495 1.1 1280 0.9
+                     2
+                                                                                       2175 1.7 2100 1.6 1945 1.4                                       1700 1.2 1465 1.0
+                     1
+                                                                                                                                        2120 1.7        1920 1.5 1685 1.2
+                     0
+                                                                                                                                                        2125 1.9 1900 1.6
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.  Operation in this zone will likely exceed FLA limits.                         Operation in this zone outside of core airflow limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                      CORE PERFORMANCE
+
+              Standard Electrical Specifications                                         Optional Factory Installed                                      Airflow (CFM)
+                                                                                       VFD Electrical Specifications
+
+                                                        Max.                                      Max.                                       500        1000        1500       2000
+                                                                                                                                        90%
+HP     Volts  HZ  Phase      FLA     Min. Cir.          Overcurrent     FLA            Min. Cir.  Overcurrent        Effectiveness (%)
+                          per motor   Amps              Protection   per motor          Amps      Protection
+
+                                                        Device                                    Device                                70%
+
+1.5 120 60 Single 15.2               34.2               45
+
+     208-230 60 Single 8.2-7.6 18.5                     25           4.6-4.8 20.6                 25                                    50%
+
+1.5  208-230  60  Three   4.6-4.8    10.8               15           4.6-4.8 11.9                 15
+       460    60  Three     2.4      5.4                                                          15
+                                                        15           2.4                     5.9
+
+       575 60 Three 1.8              4.1                15           1.8                     4.5  15                                    30%
+
+2.0 120 60 Single 20.0               45.0               60                                                                                      At AHRI 1060 standard conditions.
+                                                                                                                                                See all AHRI certified ratings at www.ahrinet.org.
+     208-230 60 Single 10.8-10.0 24.3                   35           6.6-5.8 28.3                 30
+
+2.0  208-230  60  Three   6.6-5.8    14.9               20           6.6-5.8 16.3                 20
+       460    60  Three     2.9      6.5                                                          15
+                                                        15           2.9                     7.2
+
+       575 60 Three 2.4              5.4                15           2.4                     5.9  15
+
+Specifications may be subject to change without notice.
+
+70 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE2XINV Energy Recovery Ventilator Standard
+
+                                                                                                                                                                50 3/8" Overall                           ABBREVIATIONS
+                                                                                                                                                                                                          EA: Exhaust Air to outside
+                                                                                                                                             42" Overall                                                  OA: Outside Air intake
+                                                                                                                                                  41 5/8" Case                                            RA: Room Air to be exhausted
+                                                                                                                                                                                                          FA: Fresh Air to inside
+                                                                                                                                                                Door                 33 5/8" Minimum      INSTALLATION ORIENTATION
+                                                                                                                                                                Swing                   Service Area      Unit must be installed in orientation
+                                                                                                                                                                                                          shown.
+                                                                                                                                                                                                          NOTE
+                                                                                                                                                                                                          1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                          DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                          NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                          2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                          TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                          3. MIN. DUCT CLEARANCE FROM
+                                                                                                                                                                                                          DAMPER BLADES WHEN FULLY
+                                                                                                                                                                                                          OPENED TO BE 2". SMACNA RULES
+                                                                                                                                                                                                          APPLY.
+
+                                                                                 RA Damper   RA Inlet                                         5" Damper         45 1/4" Minimum                           OA Damper            OA Inlet
+                                                                                 Location    24" X 14"                                       Frames Typ.          Service Area                            Location             24" X 14"
+                                                                                 (Optional)  Duct Receiving                                                                                               (Optional)           Duct Receiving
+                                                                                             Flange                                                  RA            TOP VIEW                                                    Flange
+                                                                      8 1/4" Typ.
+                                                                                                                                                 E-Box                 34 7/8" Case
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 71                                                                                                                                  OA
+
+                                                                      52 3/8" Overall                                                                                                 Pressure Ports      3/4" - 1 7/8"
+                                                                          51 5/8" Case                                                                                                (4) Typ.               Typ.
+                                                                                                                          9 3/8"
+                                                                                                                              Wiring                                                                                                                      1 3/4" Typ.
+                                                                                                                                   37" Typ.
+
+                                                                                                                                                      FA                                              EA
+
+                                                                                                                           CL 5 3/8"         Disconnect                               4 1/4" Duct
+                                                                                                                           Wiring                   Switch                            Flange Typ.
+
+                                                                                                                                                                CL 5 3/4" Power In                                  16" X 12"  10 3/8" Typ.
+                                                                                                                                                                CL 2 5/8" Control In                      Duct Receiving
+                                                                                                                                                                (2) 7/8" Holes
+                                                                                                                                                                for Wiring in                                  Flange Typ.
+                                                                                                                                                                Bottom of E-Box
+
+                                                                                                LEFT VIEW                                                       FRONT VIEW                                RIGHT VIEW
+
+                                                                           AIRFLOW CONFIGURATION                                                                                                                    UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                                                    Must be mounted as shown. RA/EA airstream can
+                                                                      MoAdvaeilal:bleHaEs2shXowINn Vin dimension drawing.                                                                                           be switched with OA/FA airstream unless certain
+                                                                      Drawing Type: Unit Dimension                                                                                                                  options are selected.
+                                                                      Version: MAY18
+
+                                                                                                                                                                                     HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 2XINV                                                             Energy Recovery Ventilator
+                                                                     Standard with Bypass Economizer
+
+INDOOR UNIT                                                          SPECIFICATIONS                                                          Options:
+                                                                                                                                             Onboard variable frequency drives (VFDs) -
+Download specification at:                                           Ventilation Type:
+renewaire.com/specifications                                         Static plate, heat and humidity transfer                                   one or both airstreams
+                                                                                                                                             Shaft grounding ring on motors with VFDs
+                                                                     Typical Airflow Range: 500-2,200 CFM                                     Fused disconnect
+                                                                                                                                             Integrated programmable controls -
+                                                                     AHRI 1060 Certified Core: Two L125-G5
+                                                                                                                                                enhanced, premium
+                                                                     Standard Features:                                                      Bypass economizer damper
+                                                                     TEFC Premium efficiency motors
+                                                                     Motor starters                                                             (see bypass DIM drawing) -
+                                                                     Non-fused disconnect                                                       dry-bulb temperature controls (standard),
+                                                                     24 VAC transformer/relay package                                           enthalpy controls (option)
+                                                                     Cross-core differential pressure ports                                  Class 1 low leakage motorized isolation dampers -
+                                                                                                                                                OA, RA or both airstreams
+                                                                     Filters:                                                                Qty. 2, Factory mounted filter alarms -
+                                                                     Total qty. 4, MERV 8: 20" x 20" x 2"                                       both airstreams
+                                                                                                                                             Double wall construction
+                                                                     Unit Dimensions & Weight:                                               Exterior paint - white, custom colors
+                                                                     50 1/2" L x 42" W x 52 1/2" H
+                                                                     363-583 lbs., varies by option(s)                                       Accessories:
+                                                                                                                                             Filters - MERV 13, 2" (shipped loose)
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                          Digital time clock - wall mount (TC7D-W),
+                                                                     70" L x 47" W x 57" H
+                                                                     678 lbs.                                                                   in exterior enclosure (TC7D-E)
+                                                                                                                                             Carbon dioxide sensor/control -
+                                                                     Motor(s):
+                                                                     Qty. 2, Belt drive blower/standard motor packages                          wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                             IAQ sensor - wall mount (IAQ-W),
+                                                                        with adjustable sheaves (see table below)
+                                                                                                                                                duct mount (IAQ-D)
+                                                                                                                                             Motion occupancy sensor/control -
+
+                                                                                                                                                ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                             Smoke Detector - duct mount (SD-D)
+                                                                                                                                             Electric duct heater - EK series (1–175 kW)
+                                                                                                                                             Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                (50-400 MBH), installed downstream of any fans
+
+AIRFLOW PERFORMANCE
+
+                  Sheave                                                                     External Static Pressure (in. w.g.)
+                    Adj.
+Motor  Blower      Turns             0.00               0.25                           0.50           0.75                                   1.00             1.25             1.50
+ HP     RPM        Open       SCFM BHP                               Thermal Performance Ratings G5 2015.2.xlsx                                               2 Cores (IOM)
+                              1735 0.8                  SCFM BHP SCFM BHP SCFM BHP SCFM BHP                                                             SCFM BHP SCFM BHP
+ 1.5    1146         4        1975 1.1
+        1302                                            1670 0.7 1520 0.7 1205 0.5                                                      900        0.4
+ 2.0    1458         2
+        1503                                            1925 1.1 1835 1.0 1615 0.9 1340 0.8                                                             1080 0.6          670                      0.4
+        1581         0
+        1658                                                                           2100 1.5 1970 1.4 1755 1.3                                       1495 1.1 1280 0.9
+                     2
+                                                                                       2175 1.7 2100 1.6 1945 1.4                                       1700 1.2 1465 1.0
+                     1
+                                                                                                                                        2120 1.7        1920 1.5 1685 1.2
+                     0
+                                                                                                                                                        2125 1.9 1900 1.6
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.  Operation in this zone will likely exceed FLA limits.                         Operation in this zone outside of core airflow limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                      CORE PERFORMANCE
+                     Standard Electrical Specifications
+                                                                                        Optional Factory Installed                                      Airflow (CFM)
+                                                                                       VFD Electrical Specifications
+
+                                                            Max.                                      Max.                                   500        1000        1500       2000
+                                                        Overcurrent                               Overcurrent                           90%
+HP     Volts  HZ  Phase      FLA     Min. Cir.          Protection      FLA            Min. Cir.  Protection         Effectiveness (%)
+                          per motor   Amps                           per motor          Amps
+                                                           Device                                    Device
+                                                                                                                                        70%
+1.5 120 60 Single 15.2               34.2                    45
+
+     208-230 60 Single 8.2-7.6 18.5                          25      4.6-4.8 20.6                 25                                    50%
+                                                             15
+1.5  208-230  60  Three   4.6-4.8    10.8                    15      4.6-4.8 11.9                 15
+       460    60  Three     2.4      5.4                     15
+                                                                     2.4                     5.9  15
+                                                             60
+       575 60 Three 1.8              4.1                             1.8                     4.5  15                                    30%
+                                                             35
+2.0 120 60 Single 20.0               45.0                    20                                                                                 At AHRI 1060 standard conditions.
+                                                             15                                                                                 See all AHRI certified ratings at www.ahrinet.org.
+     208-230 60 Single 10.8-10.0 24.3                        15      6.6-5.8 28.3                 30
+
+2.0  208-230  60  Three   6.6-5.8    14.9                            6.6-5.8 16.3                 20
+       460    60  Three     2.9      6.5
+                                                                     2.9                     7.2  15
+
+       575 60 Three 2.4              5.4                             2.4                     5.9  15
+
+Specifications may be subject to change without notice.
+
+72 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE2XINV Energy Recovery Ventilator Standard with Bypass Economizer
+
+                                                                                                                                                                51 1/2" Overall                                                                     ABBREVIATIONS
+                                                                                                                                                                                                                                                    EA: Exhaust Air to outside
+                                                                          16" X 16" Bypass Duct Connection                                                                                                                                          OA: Outside Air intake
+                                                                      (Direct Mount to Damper, By Others)                                                                                                                                           RA: Room Air to be exhausted
+                                                                                                                                                                                                                                                    FA: Fresh Air to inside
+                                                                                                   BP                                                                                                                                               BP: Bypass Air Intake
+
+                                                                                                                                                 42" Overall                                                                                        INSTALLATION ORIENTATION
+                                                                                                                                                      41 5/8" Case                                                                                  Unit must be installed in orientation
+                                                                                                                                                                                                        33 5/8" Minimum                             shown.
+                                                                                                                                                                                                           Service Area
+                                                                         RA                                                           OA                                                                                                            NOTE
+                                                                          Face                                                           Bypass                                                                                                     1. UNLESS OTHERWISE SPECIFIED,
+                                                                      Damper                                                             Damper                                                                                                     DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                    NEAREST EIGHTH OF AN INCH.
+                                                                         FA                                                            EA
+                                                                                                                                                                                                                                                    2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                    TO CHANGE WITHOUT NOTICE.
+
+                                                                      BYPASS AIRFLOW SCHEMATIC                                                                  Door                                                                                3. MIN. DUCT CLEARANCE
+                                                                                                                                                                Swing                                                                               FROM DAMPER BLADE WHEN FULLY
+                                                                                      FRONT VIEW                                                                                                                                                    OPENED TO BE 2". SMACNA RULES
+                                                                                                                                                                                                                                                    APPLY.
+
+                                                                                                                                                                34 7/8" Minimum                                                                     4. UNITS WITH BYPASS WILL REQUIRE
+                                                                                                                                                                  Service Area                                                                      ADDITIONAL SPACE FOR THE
+                                                                                                                                                                                                                                                    CONNECTION OF THE BYPASS DUCT
+                                                                                                                                                                  TOP VIEW                                                                          (BY OTHERS).
+
+                                                                      RA Inlet                              Isolation Damper                                                                                                                        5. FOR INSTALLATION DETAILS, REFER
+                                                                      24" X 14"                             (Optional)                                                                                                                              TO I&O MANUAL SUPPLEMENT FOR
+                                                                      Duct Receiving                        Acts as Face Damper                                                                                                                     BYPASS.
+                                                                      Flange                                for Bypass Units
+                                                                                                                                                                                                                                         OA Inlet
+                                                                       8 1/4"
+                                                                                                                                                  5" Damper                             4 1/4" Duct                                      24" X 14"
+                                                                                                                                                 Frames Typ.                            Flange Typ.
+                                                                                                                                                                34 7/8" Case                                                             Duct Receiving   8 1/4"
+                                                                                                                                                     RA                                    OA                                            Flange                  OA Damper
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 73
+                                                                                                                                                 E-Box                                       BP                                                           Location
+
+                                                                                                                                                                                                                                                          (Optional)
+
+                                                                      52 3/8" Overall
+                                                                           51 5/8" Case
+                                                                                                                       9 3/8"
+                                                                                                                           Wiring
+                                                                                                                                37"
+                                                                                                                                                                                                                                                         3/4" - 1 7/8"
+                                                                                                                                                                                                                                                            Typ.
+                                                                                                                                                                                                                                                                  17 5/8"
+                                                                                                                                                                                                                                                                                                            1 3/4" Typ.
+                                                                                                                                                                                                                                                                                                                 37"
+                                                                         Bypass                                                                          FA                                                                EA
+                                                                      Location                                                        CL 5 3/8"                   CL 5 3/4" Power In                                                       16" X 16"      10 3/8"
+                                                                                                                                      Wiring     Disconnect       CL 2 5/8" Control In                                   Pressure Ports       Bypass      12 3/8"
+                                                                                                 16" X 12"                                              Switch    (2) 7/8" Holes                                         (4) Typ.
+                                                                                      Duct Receiving                                                              for Wiring in                                                            Damper
+                                                                                                                                                                  Bottom of E-Box                                                          Location
+                                                                                            Flange Typ.                                                                                                                                  (Optional)
+                                                                                                                                                                FRONT VIEW
+                                                                                                LEFT VIEW                                                                                                                                     RIGHT VIEW
+                                                                      MAoIRdFeLlO: HWEC2XOINNFVIG[BUyRpAaTIsOs]N
+                                                                      DArvaailwablienags sThoywpnein:dUimnenistioDn dimraweinng.sion                                                                                                                     UNIT MOUNTING & APPLICATION
+                                                                      Version: MAY18
+                                                                                                                                                                                                                                                         Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                                                                                         be switched.
+
+                                                                                                                                                                                 HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 2XRT                                                              Energy Recovery Ventilator
+                                                                     Standard
+
+ROOFTOP UNIT                                                         SPECIFICATIONS                                                          Options:
+                                                                                                                                             Onboard variable frequency drives (VFDs) -
+Download specification at:                                           Ventilation Type:
+renewaire.com/specifications                                         Static plate, heat and humidity transfer                                   one or both airstreams
+                                                                                                                                             Shaft grounding ring on motors with VFDs
+                                                                     Typical Airflow Range: 500-2,000 CFM                                     Fused disconnect
+                                                                                                                                             Integrated programmable controls -
+                                                                     AHRI 1060 Certified Core: Two L125-G5
+                                                                                                                                                enhanced, premium
+                                                                     Standard Features:                                                      Class 1 low leakage motorized isolation dampers -
+                                                                     TEFC Premium efficiency motors
+                                                                     Motor starters                                                             OA, RA or both airstreams
+                                                                     Non-fused disconnect                                                    Qty. 2, Factory mounted filter alarms -
+                                                                     24 VAC transformer/relay package
+                                                                     Cross-core differential pressure ports                                     both airstreams
+                                                                                                                                             Double wall construction
+                                                                     Filters:                                                                Exterior paint - white, custom colors
+                                                                     Total qty. 4, MERV 8: 20" x 20" x 2"
+                                                                                                                                             Accessories:
+                                                                     Unit Dimensions & Weight:                                               Filters - MERV 13, 2" (shipped loose)
+                                                                     87 1/2" L x 43 1/4" W x 44" H                                           Roof curb - standard 14"
+                                                                     498-689 lbs., varies by option(s)                                       Curb wind clip
+                                                                                                                                             Engineered combo curb for Carrier RTU
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                          Engineered combo curb for Trane RTU
+                                                                     96" L x 47" W x 50" H                                                   Digital time clock - wall mount (TC7D-W),
+                                                                     784 lbs.
+                                                                                                                                                in exterior enclosure (TC7D-E)
+                                                                     Motor(s):                                                               Carbon dioxide sensor/control -
+                                                                     Qty. 2, Belt drive blower/standard motor packages
+                                                                                                                                                wall mount (CO2-W), duct mount (CO2-D)
+                                                                        with adjustable sheaves (see table below)                            IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                duct mount (IAQ-D)
+                                                                                                                                             Motion occupancy sensor/control -
+
+                                                                                                                                                ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                             Smoke Detector - duct mount (SD-D)
+                                                                                                                                             Electric duct heater - EK series (1–175 kW);
+
+                                                                                                                                                designed for indoor ductwork installation only
+                                                                                                                                             Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                (50-400 MBH), installed downstream of any fans
+
+AIRFLOW PERFORMANCE
+
+                  Sheave                                                               External Static Pressure (in. w.g.)
+                    Adj.
+Motor  Blower      Turns             0.00               0.25Thermal Perfor0m.50ance Ratings G50.270515.2.xlsx 1.00                                           12.2C5ores (IOM) 1.50
+ HP     RPM        Open       SCFM BHP                                                                                                                 SCFM BHP SCFM BHP
+                              1560 0.7                  SCFM BHP SCFM BHP SCFM BHP SCFM BHP
+ 1.5    1192         4        1765 1.1
+        1348                  1970 1.5                  1460 0.7 1300 0.6 1100 0.5                                                      845       0.4
+ 2.0    1504         2        2087 1.6
+        1516                  2194 1.8                  1685 1.0 1560 0.9 1380 0.8 1210 0.7                                                            975   0.6      650                          0.4
+        1594         0
+        1671                                            1900 1.4 1800 1.3 1670 1.2 1500 1.1                                                            1345 1.0 1135 0.8
+                     2
+                                                        2000 1.5 1915 1.4 1775 1.2 1635 1.1                                                            1475 1.0 1260 0.8
+                     1
+                                                        2110 1.7 2035 1.6 1920 1.5 1765 1.3                                                            1630 1.2 1470 1.1
+                     0
+                                                                                       2145 1.9 2050 1.7 1905 1.5                                      1775 1.4 1640 1.3
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.  Operation in this zone will likely exceed FLA limits.                        Operation in this zone outside of core airflow limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                      CORE PERFORMANCE
+                     Standard Electrical Specifications
+                                                                                        Optional Factory Installed                                     Airflow (CFM)
+                                                                                       VFD Electrical Specifications
+
+                             FLA     Min. Cir.              Max.        FLA            Min. Cir.      Max.                                   500       1000  1500          2000
+                          per motor   Amps              Overcurrent  per motor          Amps      Overcurrent                           90%
+HP     Volts  HZ  Phase                                 Protection                                Protection         Effectiveness (%)
+
+                                                           Device                                    Device
+
+1.5 120 60 Single 15.2               34.2                    45                                                                         70%
+
+     208-230 60 Single 8.2-7.6 18.5                          25      4.6-4.8 20.6                 25                                    50%
+                                                             15
+1.5  208-230  60  Three   4.6-4.8    10.8                    15      4.6-4.8 11.9                 15
+       460    60  Three     2.4      5.4                     15
+                                                                     2.4               5.9        15
+                                                             60
+       575 60 Three 1.8              4.1                             1.8               4.5        15                                    30%
+                                                             35                                                                                 At AHRI 1060 standard conditions.
+2.0 120 60 Single 20.0               45.0                    20                                                                                 See all AHRI certified ratings at www.ahrinet.org.
+                                                             15
+     208-230 60 Single 10.8-10.0 24.3                        15      6.6-5.8 28.3                 30
+
+2.0  208-230  60  Three   6.6-5.8    14.9                            6.6-5.8 16.3                 20
+       460    60  Three     2.9      6.5
+                                                                     2.9               7.2        15
+
+       575 60 Three 2.4              5.4                             2.4               5.9        15
+
+Specifications may be subject to change without notice.
+
+74 RENEWAIRE.COM 1.800.627.4499
+HE2XRT (RTV/RTR) Energy Recovery Ventilator Standard
+
+                  CURB 2X                                                                                               FA (RTV)                                                16 7/8"           51" Case                                                                                     ABBREVIATIONS
+                                                                                                                       Opening                                                  9 1/2"                                                                                                         EA: Exhaust Air to outside
+                      44" I.D.                                                                                        8 1/4" X 7"                                                                                     19 5/8"                                                                  OA: Outside Air intake
+                                                                                                                                                                                                                                                                                               RA: Room Air to be exhausted
+12 5/8"                                   12 5/8"                                                                                                                                           RA                                                            RA                                   FA: Fresh Air to inside
+                                                                                                                                                                                                                                                          Opening                              RTV: Rooftop Vertical RA & FA
+38 1/8"                                        34 3/8"                                                                                                            42 3/8" Case                            12"                                             31" X 10"                            RTR: Rooftop Vertical RA Only
+   O.D.                                           I.D.                                                                                                                                                            20 3/8"                                                                      INSTALLATION ORIENTATION
+                        FA          RA                                                                                                                                                                                               33 3/4"                                                   Unit must be installed in orientation
+         26 1/4" A                          A                                                                                                         1/8"                                                                              Minimum                                                shown.
+             4"                                                                                                                                                                                                                             Service Area                                       NOTE:
+                                                                                                                                                      2                                                                                                                                        1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                        Typ.                                                                                                                                   DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                                                               NEAREST EIGHTH OF AN INCH.
+                            47 3/4" O.D.                                                                                                                                                                                                                                                       2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                                                               TO CHANGE WITHOUT NOTICE.
+                  TOP VIEW                                                                                                                                                                                     Door                                       RA Damper
+                                                                                                                                                                                                               Swing                                      Location         CURB CROSS-SECTION A-A (TYP.)
+                                                                                                                                                                                                                                                          (Optional)
+                                                                                                                                                                                                 41 1/4"                                                  (Recessed 3/4")
+
+                                                                                                                                                                  10 1/8"                     61 1/8" Minimum
+                                                                                                                                                                                                Service Area
+                                                                                                           1 1T/y8p" .                                                                                                                                                     1 1/2" X 1/4"    1 7/8"
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 75                                                                                                                             TOP VIEW                                                                  Neoprene Gasket
+
+                                                                                                                                                                                                                                                                           3/4" X 3 1/2"            14"
+                                                                                                                                                                                                                                                                           Wooden Nailer 3"
+
+                                                                                                                                                                                                                                                                                       SECTION A-A
+
+                                                                                                                                                                                                87 1/2" Overall                                                            43 1/4" Overall
+                                                                                                                                                                                              48 1/8" Lifting Lugs
+                                                                                                                                                                                                                                                                                39 1/2"
+                                                                                                                                                        E-Box                                                                                                                Lifting Lugs
+                                                                                                                                                             EA
+                                                                                                                      12 3/4" Wiring                                                                                                                                                                OA Damper
+                                                                                                                           6 1/8"
+43 7/8" Overall                                                                                                                                                                                                                                                                                     Location
+      41" Case                                                                                                                               FA
+                                                                                                                                                    RA                                                                                                    OA                                        (Optional)
+
+                                                                                                                                                        FA     RTR
+                                                                                                                                                              ONLY
+
+7 1/4"            FA (RTR)                     CL 5 3/8"                                                                                                 Disconnect                           FA                      Pressure
+                                               Wiring                                                                                                           Switch                                                Ports (4) Typ.
+                  24" X 14"                                                                                                                                                                    RTV          RA
+                                                                                                                                                      CL 5 3/4" Power In                      ONLY
+                                                                                                                                                      CL 2 5/8" Control In
+
+                                                                                                                                                      (2) 7/8" Holes
+
+        Duct Receiving                                                                                                for Wiring in
+
+                            Flange                                                                                    HERT excepBt 6ox 8txt,oLEmRT of E-Box HERT except 6x 8x, LERT
+
+                  LEFT VIEW                                                                                                                                                                   FRONT VIEW                                                                   RIGHT VIEW
+
+                                                                                                                      RTV                                                                RTR                                                                                  UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                                                                                                              Must be mounted as shown. Airstreams can not
+MDAAroavIaRdiwlaFebiLlnel:OgaHsWsTEhyo2CwpXOne: RN:TFUVIGn/UiRt RTDRAimTIOeNnsion EA                                                                          OA                EA            OA                                                                              be switched.
+
+                                                                                                                                                                                    FA
+
+Version: MAY18
+
+                                                                                                                                                                                                                      HE-SERIES
+                                                                                                                                                                                                                                                                                                                                     SPECIFICATIONS & DIMENSIONS
+
+                                                                                                              1 1T/y8p" .
+76 RENEWAIRE.COM 1.800.627.4499
+HE2XRT (RTH/RTF) Energy Recovery Ventilator Standard
+
+                   CURB 2X                                               FA (RTF)         16 7/8"                                          51" Case            19 5/8"                                       ABBREVIATIONS
+                                                                       8 1/4" X 7"        9 1/2"                                                                                                             EA: Exhaust Air to outside
+                       44" I.D.                                         Opening                                                                                                                              OA: Outside Air intake
+                                                                                                                                                                                                             RA: Room Air to be exhausted
+12 5/8"                                                  12 5/8"                                                                                                                                             FA: Fresh Air to inside
+                                                            34 3/8"                                                                                                                                          RTF: Rooftop Vertical FA Only
+38 1/8"            FA                                          I.D.                                                                                                                                          RTH: Rooftop Horizontal RA & FA
+   O.D.                                                                                                                                                                                                      INSTALLATION ORIENTATION
+                A                                        A                       Typ2. 1/8"                                                                                                                  Unit must be installed in orientation
+         26 1/4"                                                                              42 3/8" Case                                                                                                   shown.
+             4"                                                                                                                  12"                                                                         NOTE:
+                                                                                                                                                                                                             1. UNLESS OTHERWISE SPECIFIED,
+                       47 3/4" O.D.                                                                                                                                                                          DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                             NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                        Door   33 3/4"                                       2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                        Swing     Minimum                                    TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                      Service Area
+                   TOP VIEW                                                                                                            61 1/8" Minimum
+                                                                                                                                         Service Area
+                                                                                      10 1/8"                                                                                           CURB CROSS-SECTION A-A (TYP.)
+                                                                                                                                          TOP VIEW
+                                                                                                                                                                                        1 1/2" X 1/4"         1 7/8"
+                                                                                                                                                                                        Neoprene Gasket
+
+                                                                                                                                                                                        3/4" X 3 1/2"                         5 7/8"
+                                                                                                                                                                                        Wooden Nailer 3"                           14"
+
+                                                                                                                                                                                                 SECTION A-A
+
+                                                                                                                                         87 1/2" Overall                                                     43 1/4" Overall
+                                                                                                                                       48 1/8" Lifting Lugs
+                                                                                                                                                                                                                  39 1/2"
+                                                                            E-Box                                                                                                                              Lifting Lugs
+                                                                                 EA
+                                                            12 3/4" Wiring                                                                                                                                                    OA Damper
+                                                                 6 1/8"
+                                                                                                                                                                                                                              Location
+                                                                                                                                FA
+44" Overall                                                                                                                                                                         OA                                        (Optional)
+      41" Case
+                                                                            FA   RTH                                                                                        RA
+                                                                                ONLY
+                                                                                                                                                                        5" Damper
+7 1/4"             FA (RTH)                                 CL 5 3/8"       Disconnect                                                      FA                          Frames Typ.                      RA                           8 3/8"
+                                                            Wiring                 Switch                                                                      Pressure                          24" X 14"
+                                                                                                                                            RTF                Ports (4) Typ.           Duct Receiving                        RA Damper
+                                                                       CL 5 3/4" Power In                                                  ONLY                                                                               Location
+                                                                       CL 2 5/8" Control In                                                                                                         Flange                    (Optional)
+                   24" X 14"
+                                                                       (2) 7/8" Holes
+
+                Duct Receiving                                         for Wiring in
+
+                       Flange                                     HERT excepBt 6ox t8txo, LmERT of E-Box HERTexcept 6x 8x, LERT
+
+                   LEFT VIEW                                                                                                           FRONT VIEW                                                            RIGHT VIEW
+
+MAAovIaRdilaFebLlel:OaHsWsEho2CwXOn: RNTFHIG/URTRFATION                RTH                                                        RTF                                                                        UNIT MOUNTING & APPLICATION
+
+                                                                  EA        OA        EA                                               OA                                                                    Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                                             be switched.
+Drawing Type: Unit Dimension FA                                             RA                                                         RA
+
+Version: MAY18
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
+
+                                                                      FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 77
+SPECIFICATIONS & DIMENSIONS
+
+HE 2XRTC                                                                 Energy Recovery Ventilator
+                                                                         Standard
+
+ROOFTOP UNIT                                                             SPECIFICATIONS
+Direct Connect
+
+Download specification at:                                               Ventilation Type:                                                        Options:
+renewaire.com/specifications                                             Static plate, heat and humidity transfer                                 Onboard variable frequency drives (VFDs) -
+
+                                                                         Typical Airflow Range: 500-1,700 CFM                                         one or both airstreams
+                                                                                                                                                  Shaft grounding ring on motors with VFDs
+                                                                         AHRI 1060 Certified Core: Two L125-G5                                     Fused disconnect
+                                                                                                                                                  Integrated programmable controls -
+                                                                         Standard Features:
+                                                                         TEFC Premium efficiency motors                                               enhanced, premium
+                                                                         Motor starters                                                           Qty. 2, Factory mounted filter alarms -
+                                                                         Non-fused disconnect
+                                                                         24 VAC transformer/relay package                                            both airstreams
+                                                                         Cross-core differential pressure ports                                   Double wall construction
+                                                                                                                                                  Exterior paint - white, custom colors
+                                                                         Filters:
+                                                                         Total qty. 4, MERV 8: (2) 20" x 20" x 2" and                             Accessories:
+                                                                                                                                                  Filters - MERV 13, 2" (shipped loose)
+                                                                            (2) 14" x 20" x 2"                                                    RTC transition kit - for vertical RTU, for horizontal RTU
+                                                                                                                                                  Rooftop RTC transition paint - white, custom colors
+                                                                         Unit Dimensions & Weight:                                                Digital time clock - wall mount (TC7D-W),
+                                                                         77 1/4" L x 61" W x 50" H
+                                                                         566-711 lbs., varies by option(s)                                           in exterior enclosure (TC7D-E)
+                                                                                                                                                  Carbon dioxide sensor/control -
+                                                                         Max. Shipping Dimensions & Weight (on pallet):
+                                                                         80" L x 90" W x 50" H                                                       wall mount (CO2-W), duct mount (CO2-D)
+                                                                         850 lbs.                                                                 IAQ sensor - wall mount (IAQ-W),
+
+                                                                         Motor(s):                                                                   duct mount (IAQ-D)
+                                                                         Qty. 2, 2.0 HP ea., Belt drive blower/standard motor                     Motion occupancy sensor/control -
+
+                                                                            packages with adjustable sheaves (see table below)                       ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                                  Smoke Detector - duct mount (SD-D)
+
+                                                                         Note: Electric Duct Heater and Indirect Gas-Fired Duct Furnace are not available on RTC units.
+
+AIRFLOW PERFORMANCE
+
+                                                               Tie-In Directly to Rooftop A/C Unit*                                               Unit Ducted Independently*
+
+              Blower RPM Sheave Adj.                           Static Pressure in Adjacent Air Handler                    External Static Pressure (Inches Water Column)
+                Nominal Turns Open                                      (Inches Water Column)
+
+                                                          -0.75             -0.5            -0.25                    0.0                               +0.25        +0.5        +0.75
+
+                                                    CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
+
+                  1450                   0          1664 1.6 1785 1.9                                                                                               1785 1.9 1664 1.6
+
+                  1370                   1          1400 1.4 1570 1.6 1740 1.8 1900 1.9 1740 1.8 1570 1.6 1400 1.4
+
+                  1290                   2          1125 1.3 1350 1.4 1575 1.5 1727 1.6 1575 1.5 1350 1.4 1125 1.3
+
+Exhaust Air       1210                   3          945 1.0 1165 1.1 1385 1.3 1560 1.4 1385 1.3 1165 1.1 945 1.0
+
+                  1130                   4          721 0.7 Th97e8rmal P0e.9rforma12n3c5e Rati1n.g1s G5 12306155.2.xl1s.x1 1235 1.1 9728 Core0s.(9IOM) 721 0.7
+
+                  1050                   5          560 0.7 810 0.8 1060 0.9 1200 1.0 1060 0.9 810 0.8 560 0.7
+
+                  945                    6          635 0.6 765 0.6 895 0.6 1025 0.7 895 0.6 765 0.6 635 0.6
+
+                  1705                   0                                                                                                        1600 2.0 1480 1.9 1360 1.7
+
+                  1610                   1                                             1635 2.0 1555 1.9 1490 1.8 1375 1.7 1260 1.5
+
+                  1515                   2          1742 2.0 1631 1.9 1520 1.7 1430 1.6 1355 1.6 1230 1.4 1105 1.3
+
+Fresh Air         1420                   3          1620 1.7 1515 1.6 1410 1.5 1300 1.4 1230 1.4 1115 1.2 1000 1.1
+
+                  1325                   4          1465 1.5 1370 1.4 1275 1.3 1190 1.3 1120 1.2 995 1.1 870 0.9
+
+                  1230                   5          1325 1.3 1245 1.2 1165 1.1 1080 1.0 985 0.9 850 0.8 715 0.6
+
+                  1090                   6          1170 1.0 1085 0.9 1000 0.8 905 0.8 824 0.7 743 0.6 662 0.6
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.         Operation in this zone will likely exceed FLA limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+* See page 30 for installation details.
+
+ELECTRICAL DATA                                                                                                      CORE PERFORMANCE
+
+              Standard Electrical Specifications                                         Optional Factory Installed                                            Airflow (CFM)
+                                                                                       VFD Electrical Specifications
+
+                                                                 Max.                                   Max.                                      500         1000        1500  2000
+                                                                                                                                             90%
+HP   Volts    HZ  Phase                     FLA     Min. Cir.  Overcurrent     FLA     Min. Cir.        Overcurrent       Effectiveness (%)
+                                         per motor   Amps      Protection   per motor   Amps            Protection
+
+                                                                 Device                                 Device                               70%
+
+     208-230 60 Single 10.8-10.0 24.3                            35         6.6-5.8 28.3                30
+
+2.0  208-230  60  Three                  6.6-5.8    14.9         20         6.6-5.8 16.3                20                                   50%
+       460    60  Three                    2.9      6.5                                                 15
+                                                                 15         2.9        7.2
+
+     575 60 Three 2.4                               5.4          15         2.4        5.9              15
+
+                                                                                                                                             30%
+
+                                                                                                                                                     At AHRI 1060 standard conditions.
+                                                                                                                                                     See all AHRI certified ratings at www.ahrinet.org.
+
+Specifications may be subject to change without notice.
+
+78 RENEWAIRE.COM 1.800.627.4499
+HE2XRTC Energy Recovery Ventilator Standard                                                                                                                                                                      ABBREVIATION
+                                                                                                                                                                                                                 EA: Exhaust Air to outside
+                                                                                                                                                   57 3/4" Case                                                  OA: Outside Air intake
+                                                                                                                                                                1 7/8"                                           RA: Room Air to be exhausted
+                                                                                                                                Typ1. 1/8"                                                                       FA: Fresh Air to inside
+                                                                                                                                                                                                                 INSTALLATION ORIENTATION
+                                                                                                                     2 1T/y8p" .                      Door   Door           33 7/8"                              Unit must be installed in orientation
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 79                                                                                  Swing  Swing             Minimum                           shown.
+                                                                                                                                                                                   Service Area                  NOTE:
+                                                                                                                                                                                                                 1. UNLESS OTHERWISE SPECIFIED,
+61" Overall                                                                                                                                           67 5/8" Minimum                            11 1/8" Typ.  14 7/8" - 17 5/8"DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                        Service Area                                              Height AdjustmentNEAREST EIGHTH OF AN INCH.
+         39 1/2"                                                                                                                                                                                                 2. SPECIFICATIONS MAY BE SUBJECT
+      Lifting Lugs                                                                                                                                      TOP VIEW                                                 TO CHANGE WITHOUT NOTICE.
+
+                                                                                                                                                      77 1/8" Overall                                                          17 7/8"
+                                                                                                                                                                 54 7/8"                                               41 3/4" Case
+
+                                                                                                                                                              Lifting Lugs                                                   29"
+                                                                                                                                                                                                                            Typ.
+49 7/8" Overall                                                                                                                                 EA                          FA                                              4" Typ.
+                                                          3 5/8" Wiring                                                                                                       RA
+                                                                 41"                                                                    E-Box                                                                  RIGHT VIEW
+                                                                    Case                                                            Disconnect
+                    OA                                                                                                                                                                                                     UNIT MOUNTING & APPLICATION
+                                                     CL 5 1/2"                                                                             Switch                           Pressure             23 3/8"                   Must be mounted as shown. Airstreams can not
+                         LEFT VIEW                   Wiring                                                                                                                 Ports (4) Typ.             8 7/8"              be switched.
+                                                                                                                                CL 5 3/4" Power In
+       AIRFLOW CONFIGURATION                                                                                                    CL 2 5/8" Control In
+                                                                                                                                (2) 7/8" Holes
+ModAevali:labHleEa2s XshRowTnCin dimension drawing.                                                                             for Wiring in
+Drawing Type: Unit Dimension                                                                                                    Bottom of E-Box
+Version: MAY18
+                                                                                                                                                      FRONT VIEW
+
+                                                                                                                                                                            HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 3XINH                                                             Energy Recovery Ventilator
+                                                                     Standarrdd & Bypass Economizer Option
+
+INDOOR UNIT                                                          SPECIFICATIONS
+
+Download specification at:                                           Ventilation Type:                                                   Options:
+renewaire.com/specifications                                         Static plate, heat and humidity transfer                            Onboard variable frequency drives (VFDs) -
+
+AIRFLOW PERFORMANCE                                                  Typical Airflow Range: 750-3,300 CFM                                    one or both airstreams
+                                                                                                                                         Shaft grounding ring on motors with VFDs
+                                                                     AHRI 1060 Certified Core: Three L125-G5                              Fused disconnect
+                                                                                                                                         Integrated programmable controls -
+                                                                     Standard Features:
+                                                                     TEFC Premium efficiency motors                                          enhanced, premium
+                                                                     Motor starters                                                      Bypass economizer damper
+                                                                     Non-fused disconnect
+                                                                     24 VAC transformer/relay package                                       (see bypass DIM drawing) -
+                                                                     Cross-core differential pressure ports                                 dry-bulb temperature controls (standard),
+                                                                                                                                            enthalpy controls (option)
+                                                                     Filters:                                                            Class 1 low leakage motorized isolation dampers -
+                                                                     Total qty. 6, MERV 8: 20" x 20" x 2"                                   OA, RA or both airstreams
+                                                                                                                                         Qty. 2, Factory mounted filter alarms -
+                                                                     Unit Dimensions & Weight:                                              both airstreams
+                                                                     72 1/2" L x 63 1/4" W x 44" H                                       Double wall construction
+                                                                     628-934 lbs., varies by option(s)                                   Exterior paint - white, custom colors
+
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                      Accessories:
+                                                                     80" L x 70" W x 50" H                                               Filters - MERV 13, 2" (shipped loose)
+                                                                     1,029 lbs.                                                          Digital time clock - wall mount (TC7D-W),
+
+                                                                     Motor(s):                                                              in exterior enclosure (TC7D-E)
+                                                                     Qty. 2, Belt drive blower/standard motor packages                   Carbon dioxide sensor/control -
+
+                                                                        with adjustable sheaves (see table below)                           wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                         IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                            duct mount (IAQ-D)
+                                                                                                                                         Motion occupancy sensor/control -
+
+                                                                                                                                            ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                         Smoke Detector - duct mount (SD-D)
+                                                                                                                                         Electric duct heater - EK series (1–175 kW)
+                                                                                                                                         Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                            (50-400 MBH), installed downstream of any fans
+
+                    Sheave                                                             External Static Pressure (in. w.g.)
+                      Adj.
+Motor  Blower        Turns         0.00                        0.25                           0.50         0.75                            1.00          1.25        1.50
+ HP     RPM          Open   SCFM BHP                    SCFM BHP                       SCFM BHP     SCFM BHP                        SCFM BHP       SCFM BHP    SCFM BHP
+
+              1189  4       2185       1.0              2095 Th0e.9rmal P1e9r0f0orman0c.e8 Rating1s58G05 20150..62.xlsx 800                   0.4       3 Cores (IOM)
+
+2.0           1329  2       2440 1.4 2360 1.3 2220 1.2 2020 1.0 1640 0.8                                                                           850  0.4
+
+              1470  0       2700 1.9 2640 1.8 2520 1.6 2360 1.5 2150 1.8 1770 1.0 1110 0.6
+
+              1496  3       2905 2.4 2815 2.3 2675 2.1 2505 1.9 2340 1.8 2220 1.6 1655 1.2
+
+3.0           1560  2       3030 2.7 2945 2.6 2825 2.5 2655 2.3 2445 2.1 2325 1.9 1990 1.6
+
+              1656  0.5                                                                3040 3.0 2875 2.8 2720 2.6 2575 2.4 2380 2.2
+
+              1688  0                                                                               2950 2.9 2800 2.8 2650 2.6 2490 3.0
+
+              1686  3       3300 3.5 3225 3.4 3015 3.2 2855 3.0 2800 2.8 2645 2.6 2470 2.4
+
+5.0           1764  1.5                                                                3290 3.8 3145 3.5 2995 3.3 2850 3.1 2705 2.9
+                                                                                                               3300 4.1 3175 3.8 3040 3.6 2900 3.4
+              1843  0
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.  Operation in this zone will likely exceed FLA limits.                    Operation in this zone outside of core airflow limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                  CORE PERFORMANCE
+
+              Standard Electrical Specifications                       Optional Factory Installed                                                    Airflow (CFM)
+                                                                     VFD Electrical Specifications
+                                                                                                                                              1000 1500 2000 2500 3000 3500
+                                                        Max.                                        Max.                                 500
+                                                                                                                                    90%
+HP     Volts  HZ    Phase      FLA     Min. Cir.        Overcurrent     FLA            Min. Cir.    Overcurrent  Effectiveness (%)
+                            per motor   Amps            Protection   per motor          Amps        Protection
+
+                                                        Device                                      Device
+
+2.0 120 60 Single 20.0                 45.0             60                                                                          70%
+
+     208-230 60 Single 10.8-10.0 24.3                   35           6.6-5.8 28.3                   30                              50%
+
+2.0  208-230  60    Three   6.6-5.8    14.9             20           6.6-5.8 16.3                   20                              30%
+       460    60    Three     2.9      6.5                                                          15                                      At AHRI 1060 standard conditions.
+                                                        15           2.9               7.2                                                  See all AHRI certified ratings at www.ahrinet.org.
+
+       575 60 Three 2.4                5.4              15           2.4               5.9          15
+
+     208-230 60 Single 14.7-14 33.1                     40           9.4-8.5 40.2                   45
+
+3.0  208-230  60    Three   9.4-8.5    21.1             25           9.4-8.5 23.2                   25
+       460    60    Three     4.2      9.5                                                          15
+                                                        15           4.2               10.5
+
+       575 60 Three 3.3                7.4              15           3.3               8.2          15
+
+     208-230 60 Three 14.5-13.4 32.6                    45           14.5-13.4 35.9                 45
+
+5.0 460 60 Three 6.7                   15.1             20           6.7               16.6         20
+
+       575 60 Three 5.3                11.9             15           5.3               13.1         15
+
+Specifications may be subject to change without notice.
+
+80 RENEWAIRE.COM 1.800.627.4499
+HE3XINH Energy Recovery Ventilator Standard
+
+                                                                                               Typ2. 1/8"                                                                                ABBREVIATIONS
+                                                                                                                           62 1/4" Case                                                  EA: Exhaust Air to outside
+                                                                                                                                                                                         OA: Outside Air intake
+                                                                                                                                         Door   Door            33 3/4"                  RA: Room Air to be exhausted
+                                                                                                                                         Swing  Swing              Minimum               FA: Fresh Air to inside
+                                                                                                                                                                       Service Area      INSTALLATION ORIENTATION
+                                                                                                                          10 1/8"                                                        Unit must be installed in orientation
+                                                                                                                                                                                         shown.
+                                                                                                                                                                                         NOTE
+                                                                                                                                                                                         1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                         DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                         NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                         2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                         TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                         3. MIN. DUCT CLEARANCE
+                                                                                                                                                                                         FROM DAMPER BLADES WHEN FULLY
+                                                                                                                                                                                         OPENED TO BE 2". SMACNA RULES
+                                                                                                                                                                                         APPLY.
+
+                                                                                                             1 1T/y8p" .                 67 5/8" Minimum                                 OA Damper             OA Inlet
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 81                                                                       Service Area                                  Location              36" X 14"
+                                                                                                                                                                                         (Optional)            Duct Receiving
+                                                                                                                                          TOP VIEW                                                             Flange
+
+35 5/8"                                     16" X 12"                                                                         10 3/8"        72 1/2" Overall    5" Damper                  63 1/8" Overall
+                                            Duct Receiving                                                                4 1/4" Duct         57 1/8" Case      Frames Typ.              59 3/8" Lifting Lugs
+                                            Flange Typ.                                                                   Flange Typ.     54 1/2" Lifting Lugs
+                                                                                                                                                                   OA
+43 7/8" Overall                                                                                                              E-Box                                                                                             RA Damper
+      41" Case                                                                                                                                                                                                                 Location
+                                                                                                                                EA                                                                                             (Optional)
+                              21 7/8"
+                                    4 7/8"                                                                                      FA                                                   RA                                        5 7/8"
+                                                                                                                                                                                                                                      24 1/2"
+                                                                                                                        Disconnect
+                                                                                                                               Switch    CL 5 3/4" Power In     Pressure                             RA Inlet
+                                                                                                                                                                Ports (4) Typ.                      36" X 14"
+                                                                                                                                         CL 2 5/8" Control In                            Duct Receiving
+                                                                                                                                          (2) 7/8" Holes                                             Flange                    12 1/4"
+                                                                                                                                          for Wiring in
+                                                                                                                                          Bottom of E-Box
+
+                       LEFT VIEW                                                                                                                FRONT VIEW                               RIGHT VIEW
+DMroaAAvdwIaRielaiFnbl:LlegOHasTEWsy3hpoXCweIOnN:iNnHUdFinmIGietnUsDiRonimAdTraeIwOninNsgi.on
+Version: MAY18                                                                                                                                                                           UNIT MOUNTING & APPLICATION
+
+                                                                                                                                                                                         Must be mounted as shown. RA/EA airstream can
+                                                                                                                                                                                         be switched with OA/FA airstream unless certain
+                                                                                                                                                                                         options are selected.
+
+                                                                                                                                                               HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 3XINH                                                             Energy Recovery Ventilator
+                                                                     Standard with Bypass Economizer
+
+INDOOR UNIT                                                          SPECIFICATIONS
+
+Download specification at:                                           Ventilation Type:                                                   Options:
+renewaire.com/specifications                                         Static plate, heat and humidity transfer                            Onboard variable frequency drives (VFDs) -
+
+AIRFLOW PERFORMANCE                                                  Typical Airflow Range: 750-3,300 CFM                                    one or both airstreams
+                                                                                                                                         Shaft grounding ring on motors with VFDs
+                                                                     AHRI 1060 Certified Core: Three L125-G5                              Fused disconnect
+                                                                                                                                         Integrated programmable controls -
+                                                                     Standard Features:
+                                                                     TEFC Premium efficiency motors                                          enhanced, premium
+                                                                     Motor starters                                                      Bypass economizer damper
+                                                                     Non-fused disconnect
+                                                                     24 VAC transformer/relay package                                       (see bypass DIM drawing) -
+                                                                     Cross-core differential pressure ports                                 dry-bulb temperature controls (standard),
+                                                                                                                                            enthalpy controls (option)
+                                                                     Filters:                                                            Class 1 low leakage motorized isolation dampers -
+                                                                     Total qty. 6, MERV 8: 20" x 20" x 2"                                   OA, RA or both airstreams
+                                                                                                                                         Qty. 2, Factory mounted filter alarms -
+                                                                     Unit Dimensions & Weight:                                              both airstreams
+                                                                     72 1/2" L x 63 1/4" W x 44" H                                       Double wall construction
+                                                                     628-934 lbs., varies by option(s)                                   Exterior paint - white, custom colors
+
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                      Accessories:
+                                                                     80" L x 70" W x 50" H                                               Filters - MERV 13, 2" (shipped loose)
+                                                                     1,029 lbs.                                                          Digital time clock - wall mount (TC7D-W),
+
+                                                                     Motor(s):                                                              in exterior enclosure (TC7D-E)
+                                                                     Qty. 2, Belt drive blower/standard motor packages                   Carbon dioxide sensor/control -
+
+                                                                        with adjustable sheaves (see table below)                           wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                         IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                            duct mount (IAQ-D)
+                                                                                                                                         Motion occupancy sensor/control -
+
+                                                                                                                                            ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                         Smoke Detector - duct mount (SD-D)
+                                                                                                                                         Electric duct heater - EK series (1–175 kW)
+                                                                                                                                         Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                            (50-400 MBH), installed downstream of any fans
+
+                    Sheave                                                             External Static Pressure (in. w.g.)
+                      Adj.
+Motor  Blower        Turns         0.00                        0.25                           0.50         0.75                            1.00          1.25        1.50
+ HP     RPM          Open   SCFM BHP                    SCFM BHP                       SCFM BHP     SCFM BHP                        SCFM BHP       SCFM BHP    SCFM BHP
+
+              1189  4       2185       1.0              2095 Th0e.9rmal P1e9r0f0orman0c.e8 Rating1s58G05 20150..62.xlsx 800                   0.4       3 Cores (IOM)
+
+2.0           1329  2       2440 1.4 2360 1.3 2220 1.2 2020 1.0 1640 0.8                                                                           850  0.4
+
+              1470  0       2700 1.9 2640 1.8 2520 1.6 2360 1.5 2150 1.8 1770 1.0 1110 0.6
+
+              1496  3       2905 2.4 2815 2.3 2675 2.1 2505 1.9 2340 1.8 2220 1.6 1655 1.2
+
+3.0           1560  2       3030 2.7 2945 2.6 2825 2.5 2655 2.3 2445 2.1 2325 1.9 1990 1.6
+
+              1656  0.5                                                                3040 3.0 2875 2.8 2720 2.6 2575 2.4 2380 2.2
+
+              1688  0                                                                               2950 2.9 2800 2.8 2650 2.6 2490 3.0
+
+              1686  3       3300 3.5 3225 3.4 3015 3.2 2855 3.0 2800 2.8 2645 2.6 2470 2.4
+
+5.0           1764  1.5                                                                3290 3.8 3145 3.5 2995 3.3 2850 3.1 2705 2.9
+                                                                                                               3300 4.1 3175 3.8 3040 3.6 2900 3.4
+              1843  0
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.  Operation in this zone will likely exceed FLA limits.                    Operation in this zone outside of core airflow limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                  CORE PERFORMANCE
+
+              Standard Electrical Specifications                       Optional Factory Installed                                                    Airflow (CFM)
+                                                                     VFD Electrical Specifications
+                                                                                                                                              1000 1500 2000 2500 3000 3500
+                                                        Max.                                        Max.                                 500
+                                                                                                                                    90%
+HP     Volts  HZ    Phase      FLA     Min. Cir.        Overcurrent     FLA            Min. Cir.    Overcurrent  Effectiveness (%)
+                            per motor   Amps            Protection   per motor          Amps        Protection
+
+                                                        Device                                      Device
+
+2.0 120 60 Single 20.0                 45.0             60                                                                          70%
+
+     208-230 60 Single 10.8-10.0 24.3                   35           6.6-5.8 28.3                   30                              50%
+
+2.0  208-230  60    Three   6.6-5.8    14.9             20           6.6-5.8 16.3                   20                              30%
+       460    60    Three     2.9      6.5                                                          15                                      At AHRI 1060 standard conditions.
+                                                        15           2.9               7.2                                                  See all AHRI certified ratings at www.ahrinet.org.
+
+       575 60 Three 2.4                5.4              15           2.4               5.9          15
+
+     208-230 60 Single 14.7-14 33.1                     40           9.4-8.5 40.2                   45
+
+3.0  208-230  60    Three   9.4-8.5    21.1             25           9.4-8.5 23.2                   25
+       460    60    Three     4.2      9.5                                                          15
+                                                        15           4.2               10.5
+
+       575 60 Three 3.3                7.4              15           3.3               8.2          15
+
+     208-230 60 Three 14.5-13.4 32.6                    45           14.5-13.4 35.9                 45
+
+5.0 460 60 Three 6.7                   15.1             20           6.7               16.6         20
+
+       575 60 Three 5.3                11.9             15           5.3               13.1         15
+
+Specifications may be subject to change without notice.
+
+82 RENEWAIRE.COM 1.800.627.4499
+HE3XINH Energy Recovery Ventilator Standard with Bypass Economizer
+
+        30" X 16" Bypass Duct Connection                                                                                                                                                18 1/2"                           ABBREVIATIONS
+        (Direct Mount to Damper, By Others)                                                                                                                                                                               EA: Exhaust Air to outside
+                                                                                                                                                                                                 17 3/8"                  OA: Outside Air intake
+Bypass      BP                                                                                                                                                                                                            RA: Room Air to be exhausted
+                                                                                                                                                                                                                          FA: Fresh Air to inside
+Damper                                                                                                                                                                                                                    BP: Bypass Air Intake
+                                                                                                                                                                                                                          INSTALLATION ORIENTATION
+EA                                                             OA                                                                       2 1/8"                                                                            Unit must be installed in orientation
+                                                                                                                                                    62 1/4" Case                                                          shown.
+FA                                                             RA                                                                                                                                       30" X 16" Bypass  NOTE
+                                                                                                                                                                                                        Damper Location   1. UNLESS OTHERWISE SPECIFIED,
+                             Face Damper                                                                                                                                                                (Optional)        DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                          NEAREST EIGHTH OF AN INCH.
+BYPASS AIRFLOW SCHEMATIC                                                                                                                                                                                5" Damper         2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                        Frames Typ.       TO CHANGE WITHOUT NOTICE.
+                FRONT VIEW                                                                                                                                                                                                3. MIN. DUCT CLEARANCE
+                                                                                                                                                                                                                          FROM DAMPER BLADE WHEN FULLY
+                                                                                                                                                                  Door                  Door     33 3/4"                  OPENED TO BE 2". SMACNA RULES
+                                                                                                                                                                  Swing                 Swing       Minimum               APPLY.
+                                                                                                                                                                                                        Service Area      4. UNITS WITH BYPASS WILL REQUIRE
+                                                                                                                                                                  8 1/4"                                                  ADDITIONAL SPACE FOR THE
+                                                                                                                                                                                                                          CONNECTION OF THE BYPASS DUCT
+                                                                                                                                  1 1/8"                          65 5/8" Minimum                                         (BY OTHERS).
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 83                                                                                                Service Area                                          5. FOR INSTALLATION DETAILS, REFER
+                                                                                                                                                                                                                          TO I&O MANUAL SUPPLEMENT FOR
+                                                                                                                                                                   TOP VIEW                                               BYPASS.
+
+        BP                                                                                                                                                           72 3/4" Overall                                      63 1/8" Overall
+                                                                                                                                                                      57 1/8" Case
+                                                                                                                                             10 3/8"              54 1/2" Lifting Lugs                                    59 3/8" Lifting Lugs
+                                                                                                                                        4 1/4" Duct
+                                                                                                                                        Flange Typ.                                                                       OA Damper            12 1/4"  OA Inlet
+                                                                                                                                                                                                                          Location                      36" X 14"
+                                                                                                                                          E-Box                                                                           (Optional)                    Duct
+                                                                                                                                                                                                                                                        Receiving
+47 3/8" Overall                                                                                                                            EA                                                                         OA                                Flange
+     41" Case
+                                                                                                                                        FA                                                                            RA                                6"
+                                21 7/8"                                                                                                                                                                                                                         24 7/8"
+                                                                  5"
+
+                 16" X 12"                                           CL 5 3/8"  Disconnect                                                                        CL 5 3/4" Power In    Pressure                                     RA Inlet  Isolation Damper
+        Duct Receiving                                               Wiring            Switch                                                                     CL 2 5/8" Control In  Ports (4) Typ.                              36" X 14"  (Optional)
+                                                                   8 1/2" Typ.                                                                                    (2) 7/8" Holes                                          Duct Receiving       Acts as Face Damper
+             Flange Typ.                                                                                                                                          for Wiring in                                                                For Bypass Units
+                                                                                                                                                                  Bottom of E-Box                                                     Flange
+                  LEFT VIEW
+                                                                                                                                                                          FRONT VIEW                                      RIGHT VIEW
+
+MAIoRFdLeOl:WHEC3OXNINFHIG[UBRyApTaIOssN]                                                                                                                                                                                                      UNIT MOUNTING & APPLICATION
+DAvraailawbleinasgshTowynpined:imUennsiitonDdrimawiengn. sion
+Version: MAY18                                                                                                                                                                                                                                 Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                                                                               be switched.
+
+                                                                                                                                                                                        HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 3XINV                                                             Energy Recovery Ventilator
+                                                                     Standarrdd & Bypass Economizer Option
+
+INDOOR UNIT                                                          SPECIFICATIONS                                                    Options:
+                                                                                                                                       Onboard variable frequency drives (VFDs) -
+Download specification at:                                           Ventilation Type:
+renewaire.com/specifications                                         Static plate, heat and humidity transfer                             one or both airstreams
+AIRFLOW PERFORMANCE                                                                                                                    Shaft grounding ring on motors with VFDs
+                                                                     Typical Airflow Range: 750-3,300 CFM                               Fused disconnect
+                                                                                                                                       Integrated programmable controls -
+                                                                     AHRI 1060 Certified Core: Three L125-G5
+                                                                                                                                          enhanced, premium
+                                                                     Standard Features:                                                Bypass economizer damper
+                                                                     TEFC Premium efficiency motors
+                                                                     Motor starters                                                       (see bypass DIM drawing) -
+                                                                     Non-fused disconnect                                                 dry-bulb temperature controls (standard),
+                                                                     24 VAC transformer/relay package                                     enthalpy controls (option)
+                                                                     Cross-core differential pressure ports                            Class 1 low leakage motorized isolation dampers -
+                                                                                                                                          OA, RA or both airstreams
+                                                                     Filters:                                                          Qty. 2, Factory mounted filter alarms -
+                                                                     Total qty. 6, MERV 8: 20" x 20" x 2"                                 both airstreams
+                                                                                                                                       Double wall construction
+                                                                     Unit Dimensions & Weight:                                         Exterior paint - white, custom colors
+                                                                     50 3/4" L x 61 1/2" W x 62" H
+                                                                     590-999 lbs., varies by option(s)                                 Accessories:
+                                                                                                                                       Filters - MERV 13, 2" (shipped loose)
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                    Digital time clock - wall mount (TC7D-W),
+                                                                     60" L x 90" W x 70" H
+                                                                     1,094 lbs.                                                           in exterior enclosure (TC7D-E)
+                                                                                                                                       Carbon dioxide sensor/control -
+                                                                     Motor(s):
+                                                                     Qty. 2, Belt drive blower/standard motor packages                    wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                       IAQ sensor - wall mount (IAQ-W),
+                                                                          with adjustable sheaves (see table below)
+                                                                                                                                          duct mount (IAQ-D)
+                                                                                                                                       Motion occupancy sensor/control -
+
+                                                                                                                                          ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                       Smoke Detector - duct mount (SD-D)
+                                                                                                                                       Electric duct heater - EK series (1–175 kW)
+                                                                                                                                       Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                          (50-400 MBH), installed downstream of any fans
+
+                  Sheave                                                                     External Static Pressure (in. w.g.)
+                    Adj.
+Motor  Blower      Turns         0.00                   0.25                           0.50           0.75                             1.00         1.25        1.50
+ HP     RPM        Open   SCFM BHP                                                                                                            SCFM BHP    SCFM BHP
+ 2.0                      2185 0.8                      SCFM BHP SCFM BHP SCFM BHP SCFM BHP
+        1195         4    2440 1.1
+ 3.0    1355         2    2700 1.5                      2000 0.7 1725 0.5 1210 0.4                                                            3 Cores (IOM)
+        1476         0    2810 2.1                                Thermal Performance Ratings G5 2015.2.xlsx
+  5.0   1536        2.5   2985 2.5
+        1632        1.5   3100 2.8                      2270 0.9 2060 0.8 1715 0.6 1210 0.5
+        1696        0.5   3160 3.0
+        1728         0    3300 3.3                      2550 1.3 2380 1.2 2150 1.0 1750 0.8                                                   1300 0.6
+        1749         2                                                                                                                        1840 1.5 1420 1.1
+        1801         1                                  2700 2.1 2560 1.9 2370 1.8 2140 1.6                                                   2145 1.8 1855 1.6
+        1853         0                                                                                                                        2335 2.1 2065 1.9
+                                                        2880 2.4 2760 2.3 2590 2.2 2400 2.0                                                   2425 2.3 2165 2.1
+                                                                                                                                              2440 2.1 2200 1.8
+                                                        3000 2.7 2900 2.7 2735 2.5 2505 2.3                                                   2585 2.8 2350 2.1
+                                                                                                                                              2715 2.6 2500 2.4
+                                                        3055 2.9 2960 2.8 2800 2.6 2635 2.5
+
+                                                        3200 3.1 3020 2.8 2860 2.6 2660 2.3
+
+                                                        3300 3.4 3140 3.1 2980 2.8 2800 2.6
+
+                                                                                       3245 3.4 3090 3.1 2920 2.9
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.                    Operation in this zone outside of core airflow limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                CORE PERFORMANCE
+
+              Standard Electrical Specifications                       Optional Factory Installed                                                    Airflow (CFM)
+                                                                     VFD Electrical Specifications
+                                                                                                                                              1000 1500 2000 2500 3000 3500
+                                                        Max.                                      Max.                                 500
+                                                                                                                                  90%
+HP     Volts  HZ  Phase      FLA     Min. Cir.          Overcurrent     FLA            Min. Cir.  Overcurrent  Effectiveness (%)
+                          per motor   Amps              Protection   per motor          Amps      Protection
+
+                                                        Device                                    Device
+
+2.0 120 60 Single 20.0               45.0               60                                                                        70%
+
+     208-230 60 Single 10.8-10.0 24.3                   35           6.6-5.8 16.3                 30                              50%
+
+2.0  208-230  60  Three   6.6-5.8    14.9               20           6.6-5.8 28.3                 20                              30%
+       460    60  Three     2.9      6.5                                                          15                                      At AHRI 1060 standard conditions.
+                                                        15           2.9                     7.2                                          See all AHRI certified ratings at www.ahrinet.org.
+
+       575 60 Three 2.4              5.4                15           2.4                     5.9  15
+
+     208-230 60 Single 14.7-14 33.1                     40           9.4-8.5 40.2                 45
+
+3.0  208-230  60  Three   9.4-8.5    21.1               25           9.4-8.5 23.2                 25
+       460    60  Three     4.2      9.5                                                          15
+                                                        15           4.2               10.5
+
+       575 60 Three 3.3              7.4                15           3.3                     8.2  15
+
+     208-230 60 Three 14.5-13.4 32.6                    45           14.5-13.4 35.9               45
+
+5.0 460 60 Three 6.7                 15.1               20           6.7               16.6       20
+
+       575 60 Three 5.3              11.9               15           5.3               13.1       15
+
+Specifications may be subject to change without notice.
+
+84 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE3XINV Energy Recovery Ventilator Standard                                                                                                                                              ABBREVIATION
+                                                                                                                                                                                                                                                               EA: Exhaust Air to outside
+                                                                                                                                                           33 7/8" Minimum                                                                                     OA: Outside Air intake
+                                                                                                                                                              Service Area                                                                                     RA: Room Air to be exhausted
+                                                                                                                                                                                                                                                               FA: Fresh Air to inside
+                                                                                                                                                                 Door                                                                                          INSTALLATION ORIENTATION
+                                                                                                                                                                 Swing                                                                                         Unit must be installed in orientation
+                                                                      50 3/4" Overall                                                                                                                                                                          shown.
+                                                                            35 1/4" Case                                                                                                                                                                       NOTE:
+                                                                                                                                                                                                                                                               1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                          45 5/8" Minimum                                                                      DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                             Service Area                                                                      NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                               2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                               TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                                                                               3. MIN. DUCT CLEARANCE
+                                                                                                                                                                                                                                                               FROM DAMPER BLADES WHEN FULLY
+                                                                                                                                                                                                                                                               OPENED TO BE 2". SMACNA RULES
+                                                                                                                                                                                                                                                               APPLY.
+
+                                                                                TOP VIEW                                                                              RA Inlet                                                          OA Inlet                                OA Damper
+                                                                                                                                                                      36" X 14"                                                         36" X 14"                               Location
+                                                                      RA Damper                                                                                       Duct Receiving                                                    Duct Receiving                          (Optional)
+                                                                      Location                                                                                        Flange                                                            Flange
+                                                                      (Optional)
+                                                                                                                                                                                                                        5" Damper                              61 1/2" Overall
+                                                                             1 5/8" Typ.                                                                                                                                Frames Typ.                              61 1/2" Case
+
+                                                                      46 5/8" Typ.                                                                                                              RA                      OA
+                                                                           9 7/8" Typ.                                                                                                    E-Box
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 85                                                                                                                  Disconnect                        Pressure Ports  62" Overall  58" Case
+                                                                                                                                       25 5/8" Wiring                                                                   (4) Typ.
+                                                                                                                                                                                             Switch
+                                                                                                                                                                                                                               EA
+                                                                                                                                                                                                   FA
+
+                                                                                              36 5/8" Typ.                                                                            CL 5 3/4" Power In                4 1/4" Duct                  4"                       16" X 12"
+                                                                                                          CL 7 3/4" Wiring                                                            CL 2 5/8" Control In              Flange Typ.                                           Duct Receiving
+                                                                                                                                                                                      (2) 7/8" Holes for                                                                      Flange Typ.
+                                                                                            LEFT VIEW
+                                                                      DMAAvroIaaRildawFbeLleinOla:gsWHshTEoCyw3pOnXieNInNd:FiVmUIGennUsitiRonDAdTirmaIwOienNgn. sion                  Wiring in Bottom                                                         RIGHT VIEW
+                                                                      Version: MAY18
+                                                                                                                                                                                      of E-Box                                                                 UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                                                                                               Must be mounted as shown. RA/EA airstream can
+                                                                                                                                                                                                            FRONT VIEW                                         be switched with OA/FA airstream unless certain
+                                                                                                                                                                                                                                                               options are selected.
+
+                                                                                                                                                                                                                        HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 3XINV                                                             Energy Recovery Ventilator
+                                                                     Standard with Bypass Economizer
+
+INDOOR UNIT                                                          SPECIFICATIONS                                                    Options:
+                                                                                                                                       Onboard variable frequency drives (VFDs) -
+Download specification at:                                           Ventilation Type:
+renewaire.com/specifications                                         Static plate, heat and humidity transfer                             one or both airstreams
+AIRFLOW PERFORMANCE                                                                                                                    Shaft grounding ring on motors with VFDs
+                                                                     Typical Airflow Range: 750-3,300 CFM                               Fused disconnect
+                                                                                                                                       Integrated programmable controls -
+                                                                     AHRI 1060 Certified Core: Three L125-G5
+                                                                                                                                          enhanced, premium
+                                                                     Standard Features:                                                Bypass economizer damper
+                                                                     TEFC Premium efficiency motors
+                                                                     Motor starters                                                       (see bypass DIM drawing) -
+                                                                     Non-fused disconnect                                                 dry-bulb temperature controls (standard),
+                                                                     24 VAC transformer/relay package                                     enthalpy controls (option)
+                                                                     Cross-core differential pressure ports                            Class 1 low leakage motorized isolation dampers -
+                                                                                                                                          OA, RA or both airstreams
+                                                                     Filters:                                                          Qty. 2, Factory mounted filter alarms -
+                                                                     Total qty. 6, MERV 8: 20" x 20" x 2"                                 both airstreams
+                                                                                                                                       Double wall construction
+                                                                     Unit Dimensions & Weight:                                         Exterior paint - white, custom colors
+                                                                     50 3/4" L x 61 1/2" W x 62" H
+                                                                     590-999 lbs., varies by option(s)                                 Accessories:
+                                                                                                                                       Filters - MERV 13, 2" (shipped loose)
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                    Digital time clock - wall mount (TC7D-W),
+                                                                     60" L x 90" W x 70" H
+                                                                     1,094 lbs.                                                           in exterior enclosure (TC7D-E)
+                                                                                                                                       Carbon dioxide sensor/control -
+                                                                     Motor(s):
+                                                                     Qty. 2, Belt drive blower/standard motor packages                    wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                       IAQ sensor - wall mount (IAQ-W),
+                                                                          with adjustable sheaves (see table below)
+                                                                                                                                          duct mount (IAQ-D)
+                                                                                                                                       Motion occupancy sensor/control -
+
+                                                                                                                                          ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                       Smoke Detector - duct mount (SD-D)
+                                                                                                                                       Electric duct heater - EK series (1–175 kW)
+                                                                                                                                       Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                          (50-400 MBH), installed downstream of any fans
+
+                  Sheave                                                                     External Static Pressure (in. w.g.)
+                    Adj.
+Motor  Blower      Turns         0.00                   0.25                           0.50           0.75                             1.00         1.25        1.50
+ HP     RPM        Open   SCFM BHP                                                                                                            SCFM BHP    SCFM BHP
+ 2.0                      2185 0.8                      SCFM BHP SCFM BHP SCFM BHP SCFM BHP
+        1195         4    2440 1.1
+ 3.0    1355         2    2700 1.5                      2000 0.7 1725 0.5 1210 0.4                                                            3 Cores (IOM)
+        1476         0    2810 2.1                                Thermal Performance Ratings G5 2015.2.xlsx
+  5.0   1536        2.5   2985 2.5
+        1632        1.5   3100 2.8                      2270 0.9 2060 0.8 1715 0.6 1210 0.5
+        1696        0.5   3160 3.0
+        1728         0    3300 3.3                      2550 1.3 2380 1.2 2150 1.0 1750 0.8                                                   1300 0.6
+        1749         2                                                                                                                        1840 1.5 1420 1.1
+        1801         1                                  2700 2.1 2560 1.9 2370 1.8 2140 1.6                                                   2145 1.8 1855 1.6
+        1853         0                                                                                                                        2335 2.1 2065 1.9
+                                                        2880 2.4 2760 2.3 2590 2.2 2400 2.0                                                   2425 2.3 2165 2.1
+                                                                                                                                              2440 2.1 2200 1.8
+                                                        3000 2.7 2900 2.7 2735 2.5 2505 2.3                                                   2585 2.8 2350 2.1
+                                                                                                                                              2715 2.6 2500 2.4
+                                                        3055 2.9 2960 2.8 2800 2.6 2635 2.5
+
+                                                        3200 3.1 3020 2.8 2860 2.6 2660 2.3
+
+                                                        3300 3.4 3140 3.1 2980 2.8 2800 2.6
+
+                                                                                       3245 3.4 3090 3.1 2920 2.9
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.                    Operation in this zone outside of core airflow limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                CORE PERFORMANCE
+
+              Standard Electrical Specifications                       Optional Factory Installed                                                    Airflow (CFM)
+                                                                     VFD Electrical Specifications
+                                                                                                                                              1000 1500 2000 2500 3000 3500
+                                                        Max.                                      Max.                                 500
+                                                                                                                                  90%
+HP     Volts  HZ  Phase      FLA     Min. Cir.          Overcurrent     FLA            Min. Cir.  Overcurrent  Effectiveness (%)
+                          per motor   Amps              Protection   per motor          Amps      Protection
+
+                                                        Device                                    Device
+
+2.0 120 60 Single 20.0               45.0               60                                                                        70%
+
+     208-230 60 Single 10.8-10.0 24.3                   35           6.6-5.8 16.3                 30                              50%
+
+2.0  208-230  60  Three   6.6-5.8    14.9               20           6.6-5.8 28.3                 20                              30%
+       460    60  Three     2.9      6.5                                                          15                                      At AHRI 1060 standard conditions.
+                                                        15           2.9                     7.2                                          See all AHRI certified ratings at www.ahrinet.org.
+
+       575 60 Three 2.4              5.4                15           2.4                     5.9  15
+
+     208-230 60 Single 14.7-14 33.1                     40           9.4-8.5 40.2                 45
+
+3.0  208-230  60  Three   9.4-8.5    21.1               25           9.4-8.5 23.2                 25
+       460    60  Three     4.2      9.5                                                          15
+                                                        15           4.2               10.5
+
+       575 60 Three 3.3              7.4                15           3.3                     8.2  15
+
+     208-230 60 Three 14.5-13.4 32.6                    45           14.5-13.4 35.9               45
+
+5.0 460 60 Three 6.7                 15.1               20           6.7               16.6       20
+
+       575 60 Three 5.3              11.9               15           5.3               13.1       15
+
+Specifications may be subject to change without notice.
+
+86 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE3XINV Energy Recovery Ventilator Standard with Bypass Economizer
+
+                                                                                                                                                           4 1/4"                                                        ABBREVIATIONS
+                                                                                                                                                              Duct                                                       EA: Exhaust Air to outside
+                                                                                                                                                                  Flange                                                 OA: Outside Air intake
+                                                                                                                                                                     Typ.                                                RA: Room Air to be exhausted
+                                                                                                                                                                                                                         FA: Fresh Air to inside
+                                                                                                                                      34" Minimum                                    36" X 14" Bypass Duct Connection    BP: Bypass Air Intake
+                                                                                                                                      Service Area                               (Direct Mount to Damper, By Others)
+                                                                                                                                                                                                                         INSTALLATION ORIENTATION
+                                                                                                                                        Door                                                             BP              Unit must be installed in orientation
+                                                                                                                                        Swing                                                                            shown.
+                                                                      51 3/8" Overall                                                                      45 5/8" Minimum
+                                                                            35 1/4" Case                                                                      Service Area           RA                      OA          NOTE
+                                                                                                                                                                                     Face                        Bypass  1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                 Damper                          Damper  DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                         NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                     FA                       EA
+                                                                                                                                                                                                                         2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                         TO CHANGE WITHOUT NOTICE.
+
+                                                                                                                                                                                 BYPASS AIRFLOW SCHEMATIC                3. MIN. DUCT CLEARANCE
+                                                                                                                                                                                                                         FROM DAMPER BLADE WHEN FULLY
+                                                                                                                                                                                                 FRONT VIEW              OPENED TO BE 2". SMACNA RULES
+                                                                                                                                                                                                                         APPLY.
+
+                                                                                            TOP VIEW                                                                                                                     4. UNITS WITH BYPASS WILL REQUIRE
+                                                                                                                                                                                                                         ADDITIONAL SPACE FOR THE
+                                                                                                           Isolation Damper                                                                                              CONNECTION OF THE BYPASS DUCT
+                                                                                                           (Optional)                                                                                                    (BY OTHERS).
+                                                                                                           Acts as Face Damper
+                                                                                  RA Inlet                 For Bypass Units                                                                                              5. FOR INSTALLATION DETAILS, REFER
+                                                                                36" X 14"                                                                                                                                TO I&O MANUAL SUPPLEMENT FOR
+                                                                      Duct Receiving                                                Bypass                                                                               BYPASS.
+                                                                                                                                    Location
+                                                                                   Flange                                                                      5" Damper                     Pressure Ports  OA Damper   62 3/8" Overall    OA Inlet
+                                                                                                                                                              Frames Typ.                    (4) Typ.        Location        62" Case       36" X 14"
+                                                                       1 5/8"                                                                                                                                (Optional)                     Duct
+                                                                                                                                                                           RA                                                               Receiving
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 87                                                                                             E-Box                       OA                                             Flange
+
+                                                                                                                                                           Disconnect                                                                       1 3/4"
+                                                                                                                                                                  Switch
+                                                                                                                                      16" X 12"                                              BP              62" Overall
+                                                                                                                                      Duct                                   FA              EA                  58" Case
+                                                                                                                                      Receiving                                                                                                                              26"
+                                                                                                                                      Flange Typ.                                                                                                                                  46 5/8"
+                                                                      46 5/8"
+                                                                          9 7/8" Typ.                                                                      CL 5 3/4" Power In                                            36" X 14" Bypass
+                                                                               4"                                                                          CL 2 5/8" Control In                                          Damper Location
+                                                                                                                                           25 5/8" Wiring  (2) 7/8" Holes for                                            (Optional)
+                                                                                                 36 5/8" Typ.                                              Wiring in Bottom                  4 1/4" Typ.                                    5 1/4"
+                                                                                                              CL 8 1/4" Wiring                             of E-Box                                                             RIGHT VIEW
+                                                                                                                                                                                 FRONT VIEW
+                                                                                            LEFT VIEW
+                                                                                                                                                                                                                         UNIT MOUNTING & APPLICATION
+                                                                      MAoIRdFeLlO: HWEC3XOINNFVIG[BUyRpAaTIsOs]N
+                                                                      DArvaailwablienags sThoywpnein:dUimnenistioDn dimraweinng.sion                                                                                     Must be mounted as shown. Airstreams can not
+                                                                      Version: MAY18                                                                                                                                     be switched.
+
+                                                                                                                                                                                             HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 3XRT                                                              Energy Recovery Ventilator
+                                                                     Standard
+
+ROOFTOP UNIT                                                         SPECIFICATIONS
+
+Download specification at:                                           Ventilation Type:                                                 Options:
+renewaire.com/specifications                                         Static plate, heat and humidity transfer                          Onboard variable frequency drives (VFDs) -
+
+                                                                     Typical Airflow Range: 750-3,300 CFM                                  one or both airstreams
+                                                                                                                                       Shaft grounding ring on motors with VFDs
+                                                                     AHRI 1060 Certified Core: Three L125-G5                            Fused disconnect
+                                                                                                                                       Integrated programmable controls -
+                                                                     Standard Features:
+                                                                     TEFC Premium efficiency motors                                        enhanced, premium
+                                                                     Motor starters                                                    Class 1 low leakage motorized isolation dampers -
+                                                                     Non-fused disconnect
+                                                                     24 VAC transformer/relay package                                     OA, RA or both airstreams
+                                                                     Cross-core differential pressure ports                            Qty. 2, Factory mounted filter alarms -
+
+                                                                     Filters:                                                             both airstreams
+                                                                     Total qty. 6, MERV 8: 20" x 20" x 2"                              Double wall construction
+                                                                                                                                       Exterior paint - white, custom colors
+                                                                     Unit Dimensions & Weight:
+                                                                     94" L x 63 1/4" W x 44" H                                         Accessories:
+                                                                     656-972 lbs., varies by option(s)                                 Filters - MERV 13, 2" (shipped loose)
+                                                                                                                                       Roof curb - standard 14"
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                    Curb wind clip
+                                                                     80" L x 70" W x 67" H                                             Engineered combo curb for Carrier RTU
+                                                                     1,067 lbs.                                                        Engineered combo curb for Trane RTU
+                                                                                                                                       Digital time clock - wall mount (TC7D-W),
+                                                                     Motor(s):
+                                                                     Qty. 2, Belt drive blower/standard motor packages                    in exterior enclosure (TC7D-E)
+                                                                                                                                       Carbon dioxide sensor/control -
+                                                                        with adjustable sheaves (see table below)
+                                                                                                                                          wall mount (CO2-W), duct mount (CO2-D)
+AIRFLOW PERFORMANCE                                                                                                                    IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                          duct mount (IAQ-D)
+                                                                                                                                       Motion occupancy sensor/control -
+
+                                                                                                                                          ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                       Smoke Detector - duct mount (SD-D)
+                                                                                                                                       Electric duct heater - EK series (1–175 kW);
+
+                                                                                                                                          designed for indoor ductwork installation only
+                                                                                                                                       Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                          (50-400 MBH), installed downstream of any fans
+
+Motor  Blower       Sheave                                                                   External Static Pressure (in. w.g.)
+ HP     RPM           Adj.
+                     Turns           0.00               0.25                           0.50           0.75                             1.00        1.25        1.50
+        1207         Open     SCFM BHP                                                                                                       SCFM BHP    SCFM BHP
+                                                        SCFM BHP SCFM BHP SCFM BHP SCFM BHP
+                       4      2130 1.0
+                                                        1940 Th0e.8rmal P1e6r9f5orman0c.e6 Rating1s34G05 20150..42.xlsx                      3 Cores (IOM)
+                                                        2210 1.2 2005 1.0 1725 0.8 1365 0.5
+2.0           1347  2         2380 1.4
+
+              1488  0         2630 1.9                  2470 1.6 2300 1.4 2100 1.2 1800 0.9                                                  1435 0.7    820                                 0.4
+
+              1533  3         2790 2.5                  2660 2.3 2500 2.1 2290 1.8 2040 1.6                                                  1765 1.3 1265 1.0
+
+3.0           1597  2         2905 2.8                  2785 2.6 2630 2.4 2340 2.1 2200 1.9                                                  1955 1.6 1640 1.3
+
+              1661  0.5                                 2810 3.0 2760 2.7 2585 2.5 2365 2.2                                                  2140 1.9 1890 1.6
+
+              1692  0                                                                  2820 2.9 2665 2.7 2450 2.4                            2220 2.1 1980 1.8
+
+              1686  3         3110 3.5                  3000 3.2 2890 3.0 2730 2.7 2520 2.4                                                  2295 2.1 2000 1.8
+
+5.0           1764  1.5 3255 4.0                        3150 3.7 3045 3.5 2905 3.2 2720 2.9                                                  2520 2.5 2270 2.2
+
+              1843  0                                   3300 4.2 3200 4.0 3075 3.7 2910 3.4                                                  2715 3.0 2500 2.7
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.  Operation in this zone will likely exceed FLA limits.                   Operation in this zone outside of core airflow limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                CORE PERFORMANCE
+
+              Standard Electrical Specifications                       Optional Factory Installed                                                   Airflow (CFM)
+                                                                     VFD Electrical Specifications
+                                                                                                                                             1000 1500 2000 2500 3000 3500
+                               FLA     Min. Cir.            Max.        FLA            Min. Cir.      Max.                             500
+HP     Volts  HZ    Phase   per motor   Amps            Overcurrent  per motor          Amps      Overcurrent  Effectiveness (%)  90%
+                                                        Protection                                Protection
+
+                                                           Device                                    Device
+
+2.0 120 60 Single 20.0                 45.0                  60                                                                   70%
+
+     208-230 60 Single 10.8-10.0 24.3                        35      6.6-5.8 28.3                 30                              50%
+                                                             20
+2.0  208-230  60    Three   6.6-5.8    14.9                  15      6.6-5.8 16.3                 20
+       460    60    Three     2.9      6.5                   15
+                                                                     2.9                     7.2  15
+                                                             40
+       575 60 Three 2.4                5.4                   25      2.4                     5.9  15                              30%
+                                                             15                                                                           At AHRI 1060 standard conditions.
+     208-230 60 Single 14.7-14 33.1                          15      9.4-8.5 40.2                 45                                      See all AHRI certified ratings at www.ahrinet.org.
+
+3.0  208-230  60    Three   9.4-8.5    21.1                  45      9.4-8.5 23.2                 25
+       460    60    Three     4.2      9.5                   20
+                                                             15      4.24              10.5       15
+
+       575 60 Three 3.3                7.4                           3.3                     8.2  15
+
+     208-230 60 Three 14.5-13.4 32.6                                 14.5-13.4 35.9               45
+
+5.0 460 60 Three 6.7                   15.1                          6.7               16.6       20
+
+       575 60 Three 5.3                11.9                          5.3               13.1       15
+
+Specifications may be subject to change without notice.
+
+88 RENEWAIRE.COM 1.800.627.4499
+                                                                      HE3XRT (RTV/RTR) Energy Recovery Ventilator Standard
+
+                                                                                                  26 1/8"                                              RA Damper                                                                                                                          ABBREVIATIONS
+                                                                                                                                                       Location                                                                                                                           EA: Exhaust Air to outside
+                                                                              RA                                                                       (Optional)                                                                                      CURB 3X                            OA: Outside Air intake
+                                                                       10" X 42"                                                                       (Recessed 3/4")                                                                                                                    RA: Room Air to be exhausted
+                                                                      Opening                                                                                                                                                                             45 1/4"                         FA: Fresh Air to inside
+                                                                                                                                                               35 3/8"                                                                                    RA                              RTV: Rooftop Vertical RA & FA
+                                                                                                                                                              Minimum                                                                      A                                              RTR: Rooftop Vertical RA Only
+                                                                                                                                                           Service Area
+                                                                                                                                                                                                                                    13 1/4"                                               INSTALLATION ORIENTATION
+                                                                                                                                                         Door                                                                                                                             Unit must be installed in orientation
+                                                                                                                                                         Swing                                                                                                                            shown.
+
+                                                                                                                                                                                                                                                                                          NOTE:
+                                                                                                                                                                                                                                                                                          1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                                                          DIMENSIONS ARE ROUNDED TO THE
+                                                                      57 3/8" Case                                                                                                           67 1/2" Minimum                                                                              NEAREST EIGHTH OF AN INCH.
+                                                                            47 3/8"                                                                                                             Service Area          50 3/8" I.D.                                    A        54 1/8" O.D.
+                                                                                  13 3/4"                                                                                                                                                                                                                                   3 3/4"
+                                                                                                                                                                                                                                                                                          2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                                                                                                                                   14"TO CHANGE WITHOUT NOTICE.
+
+                                                                                                                                                       Door                                                                                                       FA                      CURB CROSS-SECTION A-A (TYP.)
+                                                                                                                                                       Swing
+                                                                                                                                                                                                                                                 14 1/4"
+                                                                                                     FA (RTV)                                                                                                                                     53 1/8" I.D.           4 5/8"           1 1/2" X 1/4"              1 7/8"
+                                                                                                  12" X 6 7/8"                                                                                                                                   56 7/8" O.D.                             Neoprene Gasket
+                                                                      1 1/T8Y"P                                                                            10 1/4"
+                                                                                                    Opening                                                                                                                                      TOP VIEW
+                                                                                                             45"                                                                                                                                                                          3/4" X 3 1/2"
+                                                                                                                                                                                                                                                                                          Wooden Nailer
+                                                                                                           62 1/4" Case
+                                                                                                                                                                                                                                                                                                                 3"
+                                                                                                          TOP VIEW
+
+                                                                      TY2P1/8"                                                                                                                                                                                                            SECTION A-A
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 89                              FA (RTR)                                             EA Outlet                                                                                  93 7/8" Overall                            OA Inlet                      63 1/8"
+                                                                                                  12" X 12"                                                                                                                                      55 1/4" Lift Lugs                          Damper                        Overall
+                                                                                                  Duct Receiving                                                                             E-Box                                                                                          Location
+                                                                                                  Flange                                                                                                                                                                         19 5/8"  (Optional)                 60 1/4" Lift Lugs
+
+                                                                                 44"                                                                                12 3/4"  Wiring          EA                                                                                  OA
+                                                                                    Overall
+
+                                                                                        41"
+                                                                                            Case
+
+                                                                                                                                                                                             FA                RTR
+                                                                                                                                                                                                              ONLY
+
+                                                                                                           38 3/4"                                     5 1/4"                                 Disconnect                                         FA                      Pressure Ports                              60 1/8"
+                                                                                                                  55 3/8"                                                                            Switch                                                              (4) Typ.
+                                                                                                                   Wiring
+                                                                                                                                                                                         CL 5 3/4" Power In                                       RTV  RA
+                                                                                                      LEFT VIEW                                                                          CL 2 5/8" Control In                                    ONLY
+
+                                                                      MDroadwAAveIaiRnill:aFgbHLleOTEays3WpsXheoCRw:OnTU:VNn/FiRtIGTDRUiRmAeTnIOsiNon                                    (2) 7/8" Holes                                                56 7/8"
+                                                                      Version: MAY18                                                                                                     for wiring in bottom
+                                                                                                                                                       HERT except 6x 8x,oLEfRET -Box                                                            FRONT VIEW
+                                                                                                                                                                                                              HERT except 6x 8x, LERT
+
+                                                                                                                                                                             RTV                                      RTR                                                                                   RIGHT VIEW
+
+                                                                                                                                                       EA                                OA                   EA                             OA                                                        UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                                                                                                                                       Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                                                  FA                                                                                   be switched.
+
+                                                                                                                                                                    FA               RA                                             RA
+
+                                                                                                                                                                                                                                                                      HE-SERIES
+                                                                                                                                                                                                                                                                                                                                     SPECIFICATIONS & DIMENSIONS
+
+                                 2 1/T8Y"P
+90 RENEWAIRE.COM 1.800.627.4499
+HE3XRT (RTH/RTF) Energy Recovery Ventilator Standard
+
+TY1P1/8"                                                                                                                                                                             ABBREVIATIONS
+                                                                                                                                                                                     EA: Exhaust Air to outside
+                                                                                                                                       CURB 3X                                       OA: Outside Air intake
+                                                                                                                                                                                     RA: Room Air to be exhausted
+                                                                                                                                          45 1/4"                                    FA: Fresh Air to inside
+                                                                                                                                          RA                                         RTF: Rooftop Vertical FA Only
+                                                                                                                           A                                                         RTH: Rooftop Horizontal RA & FA
+
+                                                               35 3/8"                                              13 1/4"                               FA                         INSTALLATION ORIENTATION
+                                                             Minimum                                                                                                                 Unit must be installed in orientation
+                                                           Service Area                                                                  14 1/4"                                     shown.
+                                                                                                                                          53 1/8" I.D.
+                                                             Door                                                                        56 7/8" O.D.                                NOTE:
+                                                             Swing                                                                                                                   1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                      TOP VIEW                                       DIMENSIONS ARE ROUNDED TO THE
+57 3/8" Case                                             Door                  67 1/2" Minimum                                                                                       NEAREST EIGHTH OF AN INCH.
+       13 3/4"                                           Swing                    Service Area        50 3/8" I.D.                                            A        54 1/8" O.D.
+                                                                                                                                                                                                                    3 3/4"
+                          45"                                                                                                                                                        2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                           14"TO CHANGE WITHOUT NOTICE.
+                     FA (RTF)                                                                                                                                                                                                                                         6"
+                 12" X 6 7/8"                                                                                                                                                        CURB CROSS-SECTION A-A (TYP.)
+
+                   Opening                                                                                                                                       4 5/8"              1 1/2" X 1/4"              1 7/8"
+                        62 3/8" Case                                                                                                                                                 Neoprene Gasket
+                                                             10 1/4"
+                        TOP VIEW                                                                                                                                                     3/4" X 3 1/2"
+                                                                                                                                                                                     Wooden Nailer
+
+                                                                                                                                                                                                            3"
+
+                                                                                                                                                                                     SECTION A-A
+
+                 FA (RTH)                            EA Outlet                                                                    93 7/8" Overall                                       OA Inlet                      63 1/8"
+                 12" X 12"                                                                                                       55 1/4" Lift Lugs                                     Damper                        Overall
+                 Duct Receiving                                                E-Box                                                                                                   Location
+                 Flange                                                                                                                                                  19 5/8"     (Optional)                 60 1/4" Lift Lugs
+
+44"                                                          12 3/4"           EA                                                                                        OA
+   Overall                                                      Wiring
+
+       41"                                                                                                                                                          RA
+           Case
+                                                                                                                                                                     Pressure Ports
+                                                                               FA                RTH                                                                 (4) Typ.
+                                                                                                ONLY                                                             5" Damper
+                                                                                                                                                                 Frames Typ.
+                                     38 3/4"                                Disconnect5 1/4"                                     FA                                                                    RA                12 1/4"
+                                            55 3/8"                                Switch                                                                                                      36" X 14"               60 1/8"
+                                             Wiring                                                                               RTF                                                Duct Receiving
+                                                                       CL 5 3/4" Power In                                        ONLY                                                           Flange                               RA Damper
+                                LEFT VIEW                             CL 2 5/8" Control In                                                                                                                                           Location
+       AIRFLOW CONFIGURATION                                                                                                           56 7/8"                                                                                       (Optional)
+                                                                      (2) 7/8" Holes
+ModAveaill:abHleEas3sXhoRwnT:H/RTF                                    for wiring in bottom                                       FRONT VIEW                                                                     RIGHT VIEW
+Drawing Type: Unit Dimension                         HERT except 6x 8x, LEoRTf E-Box HERTexcept 6x 8x, LERT
+Version: MAY18
+                                                                      RTH                       RTF                                                                                                        UNIT MOUNTING & APPLICATION
+
+                                                     EA                    OA  EA                                            OA                                                                            Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                                           be switched.
+                                                         FA                RA                                                RA
+
+                                                                                                FA
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
+
+                                                                      FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 91
+SPECIFICATIONS & DIMENSIONS
+
+HE 3XRTC                                                             Energy Recovery Ventilator
+                                                                     Standard
+
+ROOFTOP UNIT                                                         SPECIFICATIONS
+Direct Connect
+
+Download specification at:                                           Ventilation Type:                                                            Options:
+renewaire.com/specifications                                         Static plate, heat and humidity transfer                                     Onboard variable frequency drives (VFDs) -
+
+                                                                     Typical Airflow Range: 1,100-2,400 CFM                                           one or both airstreams
+                                                                                                                                                  Shaft grounding ring on motors with VFDs
+                                                                     AHRI 1060 Certified Core: Three L125-G5                                       Fused disconnect
+                                                                                                                                                  Integrated programmable controls -
+                                                                     Standard Features:
+                                                                     TEFC Premium efficiency motors                                                   enhanced, premium
+                                                                     Motor starters                                                               Qty. 2, Factory mounted filter alarms -
+                                                                     Non-fused disconnect
+                                                                     24 VAC transformer/relay package                                                both airstreams
+                                                                     Cross-core differential pressure ports                                       Double wall construction
+                                                                                                                                                  Exterior paint - white, custom colors
+                                                                     Filters:
+                                                                     Total qty. 5, MERV 8: (3) 20" x 20" x 2" and                                 Accessories:
+                                                                                                                                                  Filters - MERV 13, 2" (shipped loose)
+                                                                        (2) 16" x 25" x 2"                                                        RTC transition kit - for vertical RTU, for horizontal RTU
+                                                                                                                                                  Rooftop RTC transition paint - white, custom colors
+                                                                     Unit Dimensions & Weight:                                                    Digital time clock - wall mount (TC7D-W),
+                                                                     81 1/4" L x 63 1/2" W x 48 1/4" H
+                                                                     713-1,084 lbs., varies by option(s)                                             in exterior enclosure (TC7D-E)
+                                                                                                                                                  Carbon dioxide sensor/control -
+                                                                     Max. Shipping Dimensions & Weight (on pallet):
+                                                                     80" L x 90" W x 80" H                                                           wall mount (CO2-W), duct mount (CO2-D)
+                                                                     1,225 lbs.                                                                   IAQ sensor - wall mount (IAQ-W),
+
+                                                                     Motor(s):                                                                       duct mount (IAQ-D)
+                                                                     Qty. 2, 3.0 HP ea., Belt drive blower/standard motor                         Motion occupancy sensor/control -
+
+                                                                        packages with adjustable sheaves                                             ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                                  Smoke Detector - duct mount (SD-D)
+
+                                                                     Note: Electric Duct Heater and Indirect Gas-Fired Duct Furnace are not available on RTC units.
+
+AIRFLOW PERFORMANCE
+
+                                                               Tie-In Directly to Rooftop A/C Unit*                                                    Unit Ducted Indendently*
+
+              Blower RPM Sheave Adj.                           Static Pressure in Adjacent Air Handler                    External Static Pressure (Inches Water Column)
+                Nominal Turns Open                                      (Inches Water Column)
+
+                                                          -0.75             -0.5             -0.25                   0.0                               +0.25  +0.5                                       +0.75
+
+                                                        CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
+
+                  1510                   0              2010 2.7                                                                                                                 2010 2.7
+
+                  1465                   1              1920 2.3 2130 2.9                                                                                     2130 2.9 1920 2.3
+
+                  1420                   2              1830 1.9 2035 2.5 2240 3.0                                                                2240 3.0 2035 2.5 1830 1.9
+
+Exhaust Air       1375                   3              1750 1.1 1945 1.9 2140 2.6 2400 2.7 2140 2.6 1945 1.9 1750 1.1
+
+                  1330                   4              1690 1.0 Th1e8r6m0 al Pe1r.5forma2n0c3e0Ratin1g.9s G5 22031350.2.xls2x.6 2030 1.9 18360Cores1.(5IOM) 1690 1.0
+                                                        1510 0.9 1725 1.0 1940 1.1 2250 2.1 1940 1.1 1725 1.0 1510 0.9
+                  1285                   5
+
+                  1240                   6              1320 0.8 1590 0.5 1860 0.3 2165 1.5 1860 0.3 1590 0.5 1320 0.8
+
+                  1825                   0                                                                  2250 2.9 2100 2.5 1865 2.3 1630 2.1
+
+                  1770                   1                           2525 3.0 2338 2.7 2195 2.6 2025 2.3 1785 2.1 1545 1.8
+
+                  1715                   2              2605 2.7 2430 2.6 2255 2.4 2120 2.3 1960 2.0 1700 1.2 1440 1.4
+
+Fresh Air         1660                   3              2515 2.4 2345 2.2 2175 1.9 2050 1.8 1900 1.6 1620 0.6 1340 1.0
+
+                  1605                   4              2430 2.2 2270 1.8 2110 1.3 1980 1.3 1830 1.3 1560 0.4 1290 0.5
+
+                  1550                   5              2355 1.2 2185 1.1 2015 1.0 1900 0.6 1765 0.4 1540 0.3 1200 0.4
+
+                  1495                   6              2230 0.8 2090 0.7 1950 0.5 1840 0.4 1730 0.3 1500 0.2 1100 0.2
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.         Operation in this zone will likely exceed FLA limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+* See page 38 for installation details.                                                                              CORE PERFORMANCE
+
+ELECTRICAL DATA                                                              Optional Factory Installed                                                      Airflow (CFM)
+                     Standard Electrical Specifications                      VFD Electrical Specifications
+                                                                                                                                                       1000 1500 2000 2500 3000 3500
+                                                                                                                                                  500
+                                                                   Max.                                     Max.          Effectiveness (%)  90%
+                                                               Overcurrent                              Overcurrent
+HP   Volts    HZ  Phase                     FLA     Min. Cir.  Protection      FLA     Min. Cir.        Protection
+                                         per motor   Amps                   per motor   Amps
+                                                                  Device                                   Device                            70%
+
+     208-230 60 Single 14.7-14 33.1                              40         9.4-8.5 40.2                45                                   50%
+
+3.0  208-230  60  Three                  9.4-8.5    21.1         25         9.4-8.5 23.2                25                                   30%
+       460    60  Three                    4.2      9.5                                                 15                                            At AHRI 1060 standard conditions.
+                                                                 15         4.24       10.5                                                           See all AHRI certified ratings at www.ahrinet.org.
+
+     575 60 Three 3.3                               7.4          15         3.3        8.2              15
+
+Specifications may be subject to change without notice.
+
+92 RENEWAIRE.COM 1.800.627.4499
+HE3XRTC Energy Recovery Ventilator Standard
+
+                                                                                                                                                    33 7/8" Minimum                                                                                 ABBREVIATIONS
+                                                                                                                                                    Service Area                                                                                    EA: Exhaust Air to outside
+                                                                                                                                                                                                                                                    OA: Outside Air intake
+                                                                                               Door                                                 67 5/8" Minimum                                                                                 RA: Room Air to be exhausted
+                                                                                               Swing                                                   Service Area                                                                                 FA: Fresh Air to inside
+                                                                                                                                                                                                                                                    INSTALLATION ORIENTATION
+                                                                                                                                                                                                                                                    Unit must be installed in orientation
+                                                                                                                                                                                                                                                    shown.
+                                                                                                                                                                                                                                                    NOTE:
+                                                                                                                                                                                                                                                    1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                    DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                    NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                    2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                    TO CHANGE WITHOUT NOTICE.
+
+                                                                                               Door
+                                                                                               Swing
+
+                                                                                                                                          2 1T/y8p".Ty1p1./8"
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 93
+                        TOP VIEW                                                                                                                    E-Box                          81 1/4" Overall                            11 1/4" Typ.           63 1/2" Overall
+                                                                                                                                                                                                                                                       60 1/4" Case
+                                                                EA                                                                                                                          57 1/8" Case
+                                         59 3/8"                                                                                                                                                54 1/2"                                             29" Typ.
+                                      Lifting Lugs                                                                                                                                                                                                  4 3/8" Typ.
+               OA                                                                                                                                                                            Lifting Lugs
+                                                                                                                                                                                                                                                     RIGHT VIEW
+                                    CL 5 3/4" Wiring                                           5" Wiring                                                               EA                                                 FA                        45 1/4" Case
+                                                                                                                                                    Disconnect                                                         RA                                    UNIT MOUNTING & APPLICATION48 1/8" Overall
+                        LEFT VIEW                                                                                                                                                                                             25 5/8"                        Must be mounted as shown. Airstreams can not
+MDAAvIarRoialaFdbwLleeOianls:WgsHhoCTEwy3OnpXiNneRdFi:TmIGCUenUnsiRiotnADdTraiImwOinNeg.nsion                                                              Switch                                 Pressure Ports                                             be switched.
+Version: MAY18                                                                                                                                                                                    (4) Typ.                                  6 5/8"
+                                                                                                                                                                      OA
+                                                                                                                                                                                   FRONT VIEW
+                                                                                                                                                             CL 5 5/8" Power In
+                                                                                                                                                             CL 1 1/4" Control In
+                                                                                                                                                             (2) 7/8" Holes for
+                                                                                                                                                             Wiring in Bottom
+                                                                                                                                                             of E-Box
+
+                                                                                                                                                                                                           HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 4XINH                                                             Energy Recovery Ventilator
+                                                                     Standarrdd & Bypass Economizer Option
+
+INDOOR UNIT                                                          SPECIFICATIONS
+
+Download specification at:                                           Ventilation Type:                                                       Options:
+renewaire.com/specifications                                         Static plate, heat and humidity transfer                                Onboard variable frequency drives (VFDs) -
+
+AIRFLOW PERFORMANCE                                                  Typical Airflow Range: 1,000-4,400 CFM                                      one or both airstreams
+                                                                                                                                             Shaft grounding ring on motors with VFDs
+                                                                     AHRI 1060 Certified Core: Four L125-G5                                   Fused disconnect
+                                                                                                                                             Integrated programmable controls -
+                                                                     Standard Features:
+                                                                     TEFC Premium efficiency motors                                              enhanced, premium
+                                                                     Motor starters                                                          Bypass economizer damper
+                                                                     Non-fused disconnect
+                                                                     24 VAC transformer/relay package                                           (see bypass DIM drawing) -
+                                                                     Cross-core differential pressure ports                                     dry-bulb temperature controls (standard),
+                                                                                                                                                enthalpy controls (option)
+                                                                     Filters:                                                                Class 1 low leakage motorized isolation dampers -
+                                                                     Total qty. 8, MERV 8: 20" x 20" x 2"                                       OA, RA or both airstreams
+                                                                                                                                             Qty. 2, Factory mounted filter alarms -
+                                                                     Unit Dimensions & Weight:                                                  both airstreams
+                                                                     72 3/4" L x 82 3/4" W x 44" H                                           Double wall construction
+                                                                     723-1,092 lbs., varies by option(s)                                     Exterior paint - white, custom colors
+
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                          Accessories:
+                                                                     80" L x 90" W x 50" H                                                   Filters - MERV 13, 2" (shipped loose)
+                                                                     1,228 lbs.                                                              Digital time clock - wall mount (TC7D-W),
+
+                                                                     Motor(s):                                                                  in exterior enclosure (TC7D-E)
+                                                                     Qty. 2, Belt drive blower/standard motor packages                       Carbon dioxide sensor/control -
+
+                                                                        with adjustable sheaves (see table below)                               wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                             IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                duct mount (IAQ-D)
+                                                                                                                                             Motion occupancy sensor/control -
+
+                                                                                                                                                ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                             Smoke Detector - duct mount (SD-D)
+                                                                                                                                             Electric duct heater - EK series (1–175 kW)
+                                                                                                                                             Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                (50-400 MBH), installed downstream of any fans
+
+          Blower      Sheave                                                                External Static Pressure (in. w.g.)
+           RPM          Adj.
+Motor HP               Turns         0.00                      0.25                           0.50         0.75                                1.00          1.25           1.50
+                       Open   SCFM BHP                  SCFM BHP                       SCFM BHP     SCFM BHP                            SCFM BHP       SCFM BHP       SCFM BHP
+                              3215 1.5
+               1187      4    3505 2.0                  2990 1.4 2535 1.2 2120 0.9 1360 0.7                                                            1180 4 Cor0e.6s (IOM)
+                        2.5                             3300 Th1e.9rmal P3e0r0f0orman1ce.7Rating2s61G05 20151..42.xlsx 2060                            1790 1.1
+                1290    1.5   3945 2.9                                                                                                            1.1  2400 1.6 1730 1.2
+     2                   0                                                                                                                             2310 1.5 1670 1.2
+                         4    4335 3.8                                                 3220 2.0 2885 1.8 2415 1.4                                      2695 2.0 2165 1.6
+                1358     3                                                                                                                             3050 2.4 2580 2.1
+                         2                                                                                                                             3380 3.0 2930 2.5
+               1462      1                                                                                                              2900 2.0
+                         0                                                                                                                                                     3300 3.0
+               1448      4                              3765 2.8 3515 2.4 3200 2.1 2845 1.9                                                            3050 2.5 2580 2.1
+                         2                                                                                                                             3510 3.2 3100 2.8
+               1520      0                                                             3740 2.9 3475 2.6 3145 2.3                                      3900 4.0 3600 3.7
+
+     3         1591                                                                                                                     3415 2.8
+
+               1663
+
+               1735
+
+               1591                                     4185 4.0 3965 3.4 3710 3.1 3410 2.8
+                                                                                4280 4.1 4060 3.9 3800 3.5
+     5         1696                                                                                      4395 4.7 4165 4.3
+
+               1800
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.  Operation in this zone will likely exceed FLA limits.                        Operation in this zone outside of core airflow limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                      CORE PERFORMANCE
+
+                 Standard Electrical Specifications                                      Optional Factory Installed                                     Airflow (CFM)
+                                                                                       VFD Electrical Specifications
+
+                                                        Max.                                        Max.                                    1000       2000  3000     4000
+                                                                                                                                        90%
+HP      Volts    HZ   Phase      FLA Min. Cir.          Overcurrent     FLA Min. Cir.               Overcurrent      Effectiveness (%)
+                              per motor Amps            Protection   per motor Amps                 Protection
+
+                                                        Device                                      Device
+
+2.0 120 60 Single 20.0                 45.0             60                                                                              70%
+
+        208-230 60 Single 10.8-10.0 24.3                35           6.6-5.8 28.3                   30                                  50%
+
+2.0     208-230  60   Three   6.6-5.8  14.9             20           6.6-5.8 16.3                   20                                  30%
+          460    60   Three     2.9    6.5                                                          15                                          At AHRI 1060 standard conditions.
+                                                        15                             2.9  7.2                                                 See all AHRI certified ratings at www.ahrinet.org.
+
+        575 60 Three          2.4      5.4              15                             2.4  5.9     15
+
+        208-230 60 Single 14.7-14 33.1                  40           9.4-8.5 40.2                   45
+
+3.0     208-230  60   Three   9.4-8.5  21.1             25           9.4-8.5 23.2                   25
+          460    60   Three     4.2    9.5                                                          15
+                                                        15                             4.2  10.5
+
+        575 60 Three          3.3      7.4              15                             3.3  8.2     15
+
+        208-230 60 Three 14.5-13.4 32.6                 45           14.5-13.4 35.9                 45
+
+5.0 460 60 Three              6.7      15.1             20                             6.7  16.6    20
+
+        575 60 Three          5.3      11.9             15                             5.3  13.1    15
+
+Specifications may be subject to change without notice.
+
+94 RENEWAIRE.COM 1.800.627.4499
+HE4XINH Energy Recovery Ventilator Standard
+
+                                                                                                                72 3/4" Overall                                                                                                                            ABBREVIATIONS
+                                                                                                                    57 3/8" Case                                                                                                                           EA: Exhaust Air to outside
+                                                                                                                                                                                                                                                           OA: Outside Air intake
+                                                                                                                                                   82" Case                                                                                                RA: Room Air to be exhausted
+                                                                                                                                                         82 3/4" Overall                                                                                   FA: Fresh Air to inside
+                                                                                                                                                                                                                                                           INSTALLATION ORIENTATION
+                                                                                                                                                                                                                                                           Unit must be installed in orientation
+                                                                                                                                                                                                                                                           shown.
+                                                                                                                                                                                                                                                           NOTE
+                                                                                                                                                                                                                                                           1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                           DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                           NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                           2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                           TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                                                                           3. MIN. DUCT CLEARANCE
+                                                                                                                                                                                                                                                           FROM DAMPER BLADES WHEN FULLY
+                                                                                                                                                                                                                                                           OPENED TO BE 2". SMACNA RULES
+                                                                                                                                                                                                                                                           APPLY.
+
+                                                                                       38 7/8" Minimum   Door                  Door
+                                                                                          Service Area   Swing                 Swing
+                                                                                                                                                                                                                             2 1/T8y"p.
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 95                                     67 3/8" Minimum              Ty1p.1/8"
+                                                                                                           Service Area
+              34" X 12"                                                                 10 1/4"                                       5" Damper                                                                                                    OA Inlet                               OA Damper
+              Duct Receiving                                                                     4 1/4"  TOP VIEW                     Frames Typ.                                                                                                  42" X 14"                              Location
+              Flange Typ.                                                                                                                                                                                                                          Duct Receiving                         (Optional)
+                                                                                       Duct Flange         55 7/8" Lifting Lugs          OA                                                                                                        Flange
+                                                                                         E-Box Typ.                                                                                                                                                                              19 1/4" Typ.
+37 3/8" Typ.
+                                                                                            EA
+                                                                              41"Case                                                              RA                                                                                  44"Overall                                                     6"
+                                                                                             FA                                                                                                                                                                                                                24 3/4"
+                           CL 76" Wiring                                                                        56 7/8"               Pressure                                                                                                                         RA Inlet
+                           79 3/4"                                                     Disconnect                                     Ports (4) Typ.                                                                                                                  42" X 14"
+                                                                                              Switch                                                                                                                                                       Duct Receiving
+                   LEFT VIEW                                                                                                                                                                                                                                           Flange
+MAoIRdFeLlO: W HEC4XOINNFHIGURATION                              4 1/2"                                  CL 2 5/8" Control In     (2) 7/8" Holes                                                                                                   3 3/4"                        RA Damper
+DArvaailwablienags shToywpn ein:diUmennistioDn dimraweinng.sion      21 3/8"                             CL 5 3/4" Power In       for wiring in                                                                                                                                  Location
+Version: MAY18                                                                                                                    bottom of E-Box                                                                                                                                (Optional)
+
+                                                                                                                FRONT VIEW                                                                                                                                         RIGHT VIEW
+
+                                                                                                                                                                                                                                                                   UNIT MOUNTING & APPLICATION
+
+                                                                                                                                                                                                                                                                   Must be mounted as shown. RA/EA airstream can
+                                                                                                                                                                                                                                                                   be switched with OA/FA airstream unless certain
+                                                                                                                                                                                                                                                                   options are selected.
+
+                                                                                                                                      HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 4XINH                                                             Energy Recovery Ventilator
+                                                                     Standard with Bypass Economizer
+
+INDOOR UNIT                                                          SPECIFICATIONS
+
+Download specification at:                                           Ventilation Type:                                                       Options:
+renewaire.com/specifications                                         Static plate, heat and humidity transfer                                Onboard variable frequency drives (VFDs) -
+
+AIRFLOW PERFORMANCE                                                  Typical Airflow Range: 1,000-4,400 CFM                                      one or both airstreams
+                                                                                                                                             Shaft grounding ring on motors with VFDs
+                                                                     AHRI 1060 Certified Core: Four L125-G5                                   Fused disconnect
+                                                                                                                                             Integrated programmable controls -
+                                                                     Standard Features:
+                                                                     TEFC Premium efficiency motors                                              enhanced, premium
+                                                                     Motor starters                                                          Bypass economizer damper
+                                                                     Non-fused disconnect
+                                                                     24 VAC transformer/relay package                                           (see bypass DIM drawing) -
+                                                                     Cross-core differential pressure ports                                     dry-bulb temperature controls (standard),
+                                                                                                                                                enthalpy controls (option)
+                                                                     Filters:                                                                Class 1 low leakage motorized isolation dampers -
+                                                                     Total qty. 8, MERV 8: 20" x 20" x 2"                                       OA, RA or both airstreams
+                                                                                                                                             Qty. 2, Factory mounted filter alarms -
+                                                                     Unit Dimensions & Weight:                                                  both airstreams
+                                                                     72 3/4" L x 82 3/4" W x 44" H                                           Double wall construction
+                                                                     723-1,092 lbs., varies by option(s)                                     Exterior paint - white, custom colors
+
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                          Accessories:
+                                                                     80" L x 90" W x 50" H                                                   Filters - MERV 13, 2" (shipped loose)
+                                                                     1,228 lbs.                                                              Digital time clock - wall mount (TC7D-W),
+
+                                                                     Motor(s):                                                                  in exterior enclosure (TC7D-E)
+                                                                     Qty. 2, Belt drive blower/standard motor packages                       Carbon dioxide sensor/control -
+
+                                                                        with adjustable sheaves (see table below)                               wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                             IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                duct mount (IAQ-D)
+                                                                                                                                             Motion occupancy sensor/control -
+
+                                                                                                                                                ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                             Smoke Detector - duct mount (SD-D)
+                                                                                                                                             Electric duct heater - EK series (1–175 kW)
+                                                                                                                                             Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                (50-400 MBH), installed downstream of any fans
+
+          Blower      Sheave                                                                External Static Pressure (in. w.g.)
+           RPM          Adj.
+Motor HP               Turns         0.00                      0.25                           0.50         0.75                                1.00          1.25           1.50
+                       Open   SCFM BHP                  SCFM BHP                       SCFM BHP     SCFM BHP                            SCFM BHP       SCFM BHP       SCFM BHP
+                              3215 1.5
+               1187      4    3505 2.0                  2990 1.4 2535 1.2 2120 0.9 1360 0.7                                                            1180 4 Cor0e.6s (IOM)
+                        2.5                             3300 Th1e.9rmal P3e0r0f0orman1ce.7Rating2s61G05 20151..42.xlsx 2060                            1790 1.1
+                1290    1.5   3945 2.9                                                                                                            1.1  2400 1.6 1730 1.2
+     2                   0                                                                                                                             2310 1.5 1670 1.2
+                         4    4335 3.8                                                 3220 2.0 2885 1.8 2415 1.4                                      2695 2.0 2165 1.6
+                1358     3                                                                                                                             3050 2.4 2580 2.1
+                         2                                                                                                                             3380 3.0 2930 2.5
+               1462      1                                                                                                              2900 2.0
+                         0                                                                                                                                                     3300 3.0
+               1448      4                              3765 2.8 3515 2.4 3200 2.1 2845 1.9                                                            3050 2.5 2580 2.1
+                         2                                                                                                                             3510 3.2 3100 2.8
+               1520      0                                                             3740 2.9 3475 2.6 3145 2.3                                      3900 4.0 3600 3.7
+
+     3         1591                                                                                                                     3415 2.8
+
+               1663
+
+               1735
+
+               1591                                     4185 4.0 3965 3.4 3710 3.1 3410 2.8
+                                                                                4280 4.1 4060 3.9 3800 3.5
+     5         1696                                                                                      4395 4.7 4165 4.3
+
+               1800
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.  Operation in this zone will likely exceed FLA limits.                        Operation in this zone outside of core airflow limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                      CORE PERFORMANCE
+
+                 Standard Electrical Specifications                                      Optional Factory Installed                                     Airflow (CFM)
+                                                                                       VFD Electrical Specifications
+
+                                                        Max.                                        Max.                                    1000       2000  3000     4000
+                                                                                                                                        90%
+HP      Volts    HZ   Phase      FLA Min. Cir.          Overcurrent     FLA Min. Cir.               Overcurrent      Effectiveness (%)
+                              per motor Amps            Protection   per motor Amps                 Protection
+
+                                                        Device                                      Device
+
+2.0 120 60 Single 20.0                 45.0             60                                                                              70%
+
+        208-230 60 Single 10.8-10.0 24.3                35           6.6-5.8 28.3                   30                                  50%
+
+2.0     208-230  60   Three   6.6-5.8  14.9             20           6.6-5.8 16.3                   20                                  30%
+          460    60   Three     2.9    6.5                                                          15                                          At AHRI 1060 standard conditions.
+                                                        15                             2.9  7.2                                                 See all AHRI certified ratings at www.ahrinet.org.
+
+        575 60 Three          2.4      5.4              15                             2.4  5.9     15
+
+        208-230 60 Single 14.7-14 33.1                  40           9.4-8.5 40.2                   45
+
+3.0     208-230  60   Three   9.4-8.5  21.1             25           9.4-8.5 23.2                   25
+          460    60   Three     4.2    9.5                                                          15
+                                                        15                             4.2  10.5
+
+        575 60 Three          3.3      7.4              15                             3.3  8.2     15
+
+        208-230 60 Three 14.5-13.4 32.6                 45           14.5-13.4 35.9                 45
+
+5.0 460 60 Three              6.7      15.1             20                             6.7  16.6    20
+
+        575 60 Three          5.3      11.9             15                             5.3  13.1    15
+
+Specifications may be subject to change without notice.
+
+96 RENEWAIRE.COM 1.800.627.4499
+HE4XINH Energy Recovery Ventilator Standard with Bypass Economizer
+
+              34" X 16" Bypass Duct Connection                                        4 1/8" Duct      72 3/4" Overall                                                                                                  5" Damper                              ABBREVIATIONS
+              (Direct Mount to Damper, By Others)                                     Flange Typ.         57 3/8" Case                                                                                                  Frames Typ.                            EA: Exhaust Air to outside
+                                                                                                                                                                                                                                                               OA: Outside Air intake
+   Bypass                      BP                                                                      5 1/8"                     48 7/8"                                                                                                                      RA: Room Air to be exhausted
+ Damper                                                                                                                                          82" Case                                                                                                      FA: Fresh Air to inside
+                                                        OA                                               34" X 16" Bypass                                                                                                                                      BP: Bypass Air Intake
+EA                                                                                                       Damper Location                             82 7/8" Overall                                                                                           INSTALLATION ORIENTATION
+                                                                                                         (Optional)                                                                                                                                            Unit must be installed in orientation
+FA                                                             RA                                                                                                                                                                                              shown.
+                                                                                                                                                                                                                                                               NOTE
+                                                    Face Damper                                                                                                                                                                                                1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                               DIMENSIONS ARE ROUNDED TO THE
+BYPASS AIRFLOW SCHEMATIC                                                                                                                                                                                                                                       NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                               2. SPECIFICATIONS MAY BE SUBJECT
+                FRONT VIEW                                                                                                                                                                                                                                     TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                                                                               3. MIN. DUCT CLEARANCE
+                                                                                                                                                                                                                  2 1/8"38 7/8" MinimumDoorDoor                FROM DAMPER BLADE WHEN FULLY
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 97                     Service Area  Swing               Swing                                                                                                                               OPENED TO BE 2". SMACNA RULES
+                                                                                                                                                                                                                                                               APPLY.
+                                                                                                                                                                                                                                                               4. UNITS WITH BYPASS WILL REQUIRE
+                                                                                                                                                                                                                                                               ADDITIONAL SPACE FOR THE
+                                                                                                                                                                                                                                                               CONNECTION OF THE BYPASS DUCT
+                                                                                                                                                                                                                                                               (BY OTHERS).
+                                                                                                                                                                                                                                                               5. FOR INSTALLATION DETAILS, REFER
+                                                                                                                                                                                                                                                               TO I&O MANUAL SUPPLEMENT FOR
+                                                                                                                                                                                                                                                               BYPASS.
+
+       BP     34" X 12"                                                                                67 3/8" Minimum                                                                                                  1 1/8"       OA Damper                                       OA Inlet
+              Duct Receiving                                                                             Service Area                                                                                                                      47 3/8" OverallLocation                   42" X 14"
+37 3/8" Typ.  Flange Typ.                                                                                                                                                                                                                              5 7/8"(Optional)              Duct
+                                                                                                        TOP VIEW                                                                                                                                                                     Receiving
+                                                                                                                                                                                                                                                               79 1/8" Lifting Lugs  Flange
+                                                                                                        54 1/2" Lifting Lugs
+                                                                                                                                  Pressure
+                                                                                             10 1/4"                              Ports (4) Typ.
+                                                                                                E-Box
+                                                                                                                                         OA
+                                                                                            EA
+                                                                            41" Case                                                                                                                                    RA                                                                    24 5/8"
+                                                                                            FA
+                        CL 76" Wiring                          4 1/2"                                         56 7/8"                                                                                                                                          RA Inlet              19 1/8"
+                            79 3/4"                                21 3/8"            Disconnect
+                                                                                             Switch
+                   LEFT VIEW
+MAIoRdFLeOl:WHEC4OXNINFHIG[UBRyApTaIOssN]                                                              CL 2 5/8" Control In (2) 7/8" Holes                                                                                        Isolation Damper             42" X 14"             Typ.
+DAvraailawbleinasgshTowynpined:imUennsiitonDdrimawiengn. sion                                                                                                                                                                               (Optional)
+Version: MAY18                                                                                         CL 5 3/4" Power In  for wiring in                                                                                                                       Duct Receiving
+                                                                                                                           bottom of E-Box                                                                                  Acts as Face Damper
+                                                                                                                                                                                                                                     For Bypass Units          Flange
+
+                                                                                                       FRONT VIEW                                                                                                                                              RIGHT VIEW
+
+                                                                                                                                                                                                                                                               UNIT MOUNTING & APPLICATION
+
+                                                                                                                                                                                                                                                               Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                                                                                               be switched.
+
+                                                                                                                                  HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 4XINV                                                             Energy Recovery Ventilator
+                                                                     Standarrdd & Bypass Economizer Option
+
+INDOOR UNIT                                                          SPECIFICATIONS
+
+Download specification at:                                           Ventilation Type:                                                 Options:
+renewaire.com/specifications                                         Static plate, heat and humidity transfer                          Onboard variable frequency drives (VFDs) -
+
+AIRFLOW PERFORMANCE                                                  Typical Airflow Range: 1,000-4,400 CFM                                one or both airstreams
+                                                                                                                                       Shaft grounding ring on motors with VFDs
+                                                                     AHRI 1060 Certified Core: Four L125-G5                             Fused disconnect
+                                                                                                                                       Integrated programmable controls -
+                                                                     Standard Features:
+                                                                     TEFC Premium efficiency motors                                        enhanced, premium
+                                                                     Motor starters                                                    Bypass economizer damper
+                                                                     Non-fused disconnect
+                                                                     24 VAC transformer/relay package                                     (see bypass DIM drawing) -
+                                                                     Cross-core differential pressure ports                               dry-bulb temperature controls (standard),
+                                                                                                                                          enthalpy controls (option)
+                                                                     Filters:                                                          Class 1 low leakage motorized isolation dampers -
+                                                                     Total qty. 8, MERV 8: 20" x 20" x 2"                                 OA, RA or both airstreams
+                                                                                                                                       Qty. 2, Factory mounted filter alarms -
+                                                                     Unit Dimensions & Weight:                                            both airstreams
+                                                                     50 3/4" L x 81 1/2" W x 62" H                                     Double wall construction
+                                                                     753-1,196 lbs., varies by option(s)                               Exterior paint - white, custom colors
+
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                    Accessories:
+                                                                     60" L x 90" W x 70" H                                             Filters - MERV 13, 2" (shipped loose)
+                                                                     1,332 lbs.                                                        Digital time clock - wall mount (TC7D-W),
+
+                                                                     Motor(s):                                                            in exterior enclosure (TC7D-E)
+                                                                     Qty. 2, Belt drive blower/standard motor packages                 Carbon dioxide sensor/control -
+
+                                                                        with adjustable sheaves (see table below)                         wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                       IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                          duct mount (IAQ-D)
+                                                                                                                                       Motion occupancy sensor/control -
+
+                                                                                                                                          ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                       Smoke Detector - duct mount (SD-D)
+                                                                                                                                       Electric duct heater - EK series (1–175 kW)
+                                                                                                                                       Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                          (50-400 MBH), installed downstream of any fans
+
+Motor  Blower     Sheave                                                                     External Static Pressure (in. w.g.)
+ HP     RPM         Adj.
+ 2.0               Turns         0.00                   0.25                           0.50           0.75                             1.00        1.25           1.50
+        1191       Open   SCFM BHP
+ 3.0    1329              3330 1.4                      SCFM BHP SCFM BHP SCFM BHP SCFM BHP                                                  SCFM BHP SCFM BHP
+        1432         4    3715 1.9
+ 5.0    1466         2    4000 2.4                      3015 Th1e.2rmal P2e6r9fo0rmanc1e.0Rating1s91G55 20150.28.xlsx 1085 0.6                     4 Cores (IOM)
+        1462        0.5
+        1503         0    4060 2.6                      3440 1.7 3100 1.5 2485 1.3 2000 1.0                                                  1200 0.8
+        1586         3    4175 2.8
+        1668        2.5                                 3740 2.2 3480 2.0 3050 1.7 2490 1.5                                                  1900 1.2 1100 0.9
+        1710        1.5   4393 3.9
+        1627        0.5                                                                           3200 1.9 2650 1.6                          2120 1.3 1385 1.1
+        1731         0
+        1836         4                                  3810 2.4 3550 2.1 3180 1.9 2645 1.6                                                  2075 1.3 1345 1.0
+                     2
+                     0                                  3940 2.6 3700 2.4 3340 2.1 2885 1.7                                                  2300 1.5 1600 1.2
+
+                                                                                       3950 2.8 3640 2.5 3250 2.3                            2745 2.0 2170 1.7
+
+                                                                                                  3900 3.0 3600 2.7                          3155 2.4 2640 2.1
+
+                                                                                                                                  3750 3.0   3350 2.7 2975 2.4
+
+                                                        4210 3.7 4050 3.6 3800 3.3 3490 3.1                                                  3020 2.7 2385 2.4
+
+                                                                                       4350 4.3 4150 4.1 3895 3.8                            3515 3.5 3055 3.2
+
+                                                                                                  4400 5.0 4250 4.7                          3970 4.4 3550 4.0
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.  Operation in this zone will likely exceed FLA limits.                   Operation in this zone outside of core airflow limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                CORE PERFORMANCE
+
+              Standard Electrical Specifications                       Optional Factory Installed                                             Airflow (CFM)
+                                                                     VFD Electrical Specifications
+
+                                                        Max.                                      Max.                                1000   2000        3000     4000
+                                                                                                                                  90%
+HP     Volts  HZ  Phase      FLA Min. Cir.              Overcurrent     FLA Min. Cir.             Overcurrent  Effectiveness (%)
+                          per motor Amps                Protection   per motor Amps               Protection
+
+                                                        Device                                    Device
+
+2.0 120 60 Single 20.0             45.0                 60                                                                        70%
+
+     208-230 60 Single 10.8-10.0 24.3                   35           6.6-5.8 28.3                 30                              50%
+
+2.0  208-230  60  Three   6.6-5.8  14.9                 20           6.6-5.8 16.3                 20                              30%
+       460    60  Three     2.9    6.5                                                            15                                      At AHRI 1060 standard conditions.
+                                                        15           2.9                     7.2                                          See all AHRI certified ratings at www.ahrinet.org.
+
+       575 60 Three       2.4      5.4                  15           2.4                     5.9  15
+
+     208-230 60 Single 14.7-14 33.1                     40           9.4-8.5 40.2                 45
+
+3.0  208-230  60  Three   9.4-8.5  21.1                 25           9.4-8.5 23.2                 25
+       460    60  Three     4.2    9.5                                                            15
+                                                        15           4.2               10.5
+
+       575 60 Three       3.3      7.4                  15           3.3                     8.2  15
+
+     208-230 60 Three 14.5-13.4 32.6                    45           14.5-13.4 35.9               45
+
+5.0 460 60 Three          6.7      15.1                 20           6.7               16.6       20
+
+       575 60 Three       5.3      11.9                 15           5.3               13.1       15
+
+Specifications may be subject to change without notice.
+
+98 RENEWAIRE.COM 1.800.627.4499
+                                                                      50 5/8" OverallHE4XINV Energy Recovery Ventilator Standard                       45 5/8" Minimum                                                      ABBREVIATIONS
+                                                                            35 1/8" Case                                                                  Service Area                                                      EA: Exhaust Air to outside
+                                                                                                                                    34 1/8" Minimum                                                                         OA: Outside Air intake
+                                                                                                                                         Service Area                                                                       RA: Room Air to be exhausted
+                                                                                                                                                                                                                            FA: Fresh Air to inside
+                                                                                                                                                                       Door                                                 INSTALLATION ORIENTATION
+                                                                                                                                                                       Swing                                                Unit must be installed in orientation
+                                                                                                                                                                                                                            shown.
+                                                                                                                                                                                                                            NOTE
+                                                                                                                                                                                                                            1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                            DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                            NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                            2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                            TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                                            3. MIN. DUCT CLEARANCE
+                                                                                                                                                                                                                            FROM DAMPER BLADES WHEN FULLY
+                                                                                                                                                                                                                            OPENED TO BE 2". SMACNA RULES
+                                                                                                                                                                                                                            APPLY.
+
+                                                                                          TOP VIEW
+
+                                                                                          RA Damper                                    RA Inlet                                                                             OA Damper         OA Inlet
+                                                                                          Location                                     42" X 14"                                                                            Location          42" X 14"
+                                                                                          (Optional)                                   Duct Receiving                                                                       (Optional)        Duct Receiving
+                                                                                                                                       Flange                                                                                                 Flange
+                                                                                                  1 5/8" Typ.                                                                                                                81 7/8" Overall
+                                                                                                                                                                                    RA  5" Damper                             81 1/2" Case
+                                                                                                                                                                            E-Box       Frames Typ.
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 99  46 5/8" Typ.                                                                                    Disconnect25 5/8" Wiring                                                58" Case  62" Overall
+                                                                            10 1/4" Typ.                                                                                                                            OA
+                                                                                                                                                                             Switch
+                                                                                                                                                                                   FA                       Pressure Ports
+                                                                                                                                                                                                            (4) Typ.
+
+                                                                                                                                                                                                                      EA
+
+                                                                                          37 7/8" Typ.                                                 CL 5 3/4" Power In                           4 1/4" Duct                                Duct Flange4"
+                                                                                                                                                       CL 2 5/8" Control In                         Flange Typ.                                34" X 12" Typ.
+                                                                                                                                                       (2) 7/8" Holes for
+                                                                                                               CL 8" Wiring                                                                                                 RIGHT VIEW
+                                                                                                                                                       Wiring in Bottom
+                                                                                                                                                                                                                                        UNIT MOUNTING & APPLICATION
+                                                                                                                                                       of E-Box                                                                         Must be mounted as shown. RA/EA airstream can
+                                                                                                                                                                                                                                        be switched with OA/FA airstream unless certain
+                                                                                                LEFT VIEW                                                                               FRONT VIEW                                      options are selected.
+                                                                      MAoIRdFeLl:OHWE4CXOINNVFIGURATION
+                                                                      DAravaiwlabilne gas sThyopwnein: dUimneintsiDonimdraewinngs.ion
+                                                                      Version: MAY18
+
+                                                                                                                                                                                                    HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 4XINV                                                             Energy Recovery Ventilator
+                                                                     Standard with Bypass Economizer
+
+INDOOR UNIT                                                          SPECIFICATIONS
+
+Download specification at:                                           Ventilation Type:                                                 Options:
+renewaire.com/specifications                                         Static plate, heat and humidity transfer                          Onboard variable frequency drives (VFDs) -
+
+AIRFLOW PERFORMANCE                                                  Typical Airflow Range: 1,000-4,400 CFM                                one or both airstreams
+                                                                                                                                       Shaft grounding ring on motors with VFDs
+                                                                     AHRI 1060 Certified Core: Four L125-G5                             Fused disconnect
+                                                                                                                                       Integrated programmable controls -
+                                                                     Standard Features:
+                                                                     TEFC Premium efficiency motors                                        enhanced, premium
+                                                                     Motor starters                                                    Bypass economizer damper
+                                                                     Non-fused disconnect
+                                                                     24 VAC transformer/relay package                                     (see bypass DIM drawing) -
+                                                                     Cross-core differential pressure ports                               dry-bulb temperature controls (standard),
+                                                                                                                                          enthalpy controls (option)
+                                                                     Filters:                                                          Class 1 low leakage motorized isolation dampers -
+                                                                     Total qty. 8, MERV 8: 20" x 20" x 2"                                 OA, RA or both airstreams
+                                                                                                                                       Qty. 2, Factory mounted filter alarms -
+                                                                     Unit Dimensions & Weight:                                            both airstreams
+                                                                     50 3/4" L x 81 1/2" W x 62" H                                     Double wall construction
+                                                                     753-1,196 lbs., varies by option(s)                               Exterior paint - white, custom colors
+
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                    Accessories:
+                                                                     60" L x 90" W x 70" H                                             Filters - MERV 13, 2" (shipped loose)
+                                                                     1,332 lbs.                                                        Digital time clock - wall mount (TC7D-W),
+
+                                                                     Motor(s):                                                            in exterior enclosure (TC7D-E)
+                                                                     Qty. 2, Belt drive blower/standard motor packages                 Carbon dioxide sensor/control -
+
+                                                                        with adjustable sheaves (see table below)                         wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                       IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                          duct mount (IAQ-D)
+                                                                                                                                       Motion occupancy sensor/control -
+
+                                                                                                                                          ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                       Smoke Detector - duct mount (SD-D)
+                                                                                                                                       Electric duct heater - EK series (1–175 kW)
+                                                                                                                                       Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                          (50-400 MBH), installed downstream of any fans
+
+Motor  Blower     Sheave                                                                     External Static Pressure (in. w.g.)
+ HP     RPM         Adj.
+ 2.0               Turns         0.00                   0.25                           0.50           0.75                             1.00        1.25           1.50
+        1191       Open   SCFM BHP
+ 3.0    1329              3330 1.4                      SCFM BHP SCFM BHP SCFM BHP SCFM BHP                                                  SCFM BHP SCFM BHP
+        1432         4    3715 1.9
+ 5.0    1466         2    4000 2.4                      3015 Th1e.2rmal P2e6r9fo0rmanc1e.0Rating1s91G55 20150.28.xlsx 1085 0.6                     4 Cores (IOM)
+        1462        0.5
+        1503         0    4060 2.6                      3440 1.7 3100 1.5 2485 1.3 2000 1.0                                                  1200 0.8
+        1586         3    4175 2.8
+        1668        2.5                                 3740 2.2 3480 2.0 3050 1.7 2490 1.5                                                  1900 1.2 1100 0.9
+        1710        1.5   4393 3.9
+        1627        0.5                                                                           3200 1.9 2650 1.6                          2120 1.3 1385 1.1
+        1731         0
+        1836         4                                  3810 2.4 3550 2.1 3180 1.9 2645 1.6                                                  2075 1.3 1345 1.0
+                     2
+                     0                                  3940 2.6 3700 2.4 3340 2.1 2885 1.7                                                  2300 1.5 1600 1.2
+
+                                                                                       3950 2.8 3640 2.5 3250 2.3                            2745 2.0 2170 1.7
+
+                                                                                                  3900 3.0 3600 2.7                          3155 2.4 2640 2.1
+
+                                                                                                                                  3750 3.0   3350 2.7 2975 2.4
+
+                                                        4210 3.7 4050 3.6 3800 3.3 3490 3.1                                                  3020 2.7 2385 2.4
+
+                                                                                       4350 4.3 4150 4.1 3895 3.8                            3515 3.5 3055 3.2
+
+                                                                                                  4400 5.0 4250 4.7                          3970 4.4 3550 4.0
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.  Operation in this zone will likely exceed FLA limits.                   Operation in this zone outside of core airflow limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                CORE PERFORMANCE
+
+              Standard Electrical Specifications                       Optional Factory Installed                                             Airflow (CFM)
+                                                                     VFD Electrical Specifications
+
+                                                        Max.                                      Max.                                1000   2000        3000     4000
+                                                                                                                                  90%
+HP     Volts  HZ  Phase      FLA Min. Cir.              Overcurrent     FLA Min. Cir.             Overcurrent  Effectiveness (%)
+                          per motor Amps                Protection   per motor Amps               Protection
+
+                                                        Device                                    Device
+
+2.0 120 60 Single 20.0             45.0                 60                                                                        70%
+
+     208-230 60 Single 10.8-10.0 24.3                   35           6.6-5.8 28.3                 30                              50%
+
+2.0  208-230  60  Three   6.6-5.8  14.9                 20           6.6-5.8 16.3                 20                              30%
+       460    60  Three     2.9    6.5                                                            15                                      At AHRI 1060 standard conditions.
+                                                        15           2.9                     7.2                                          See all AHRI certified ratings at www.ahrinet.org.
+
+       575 60 Three       2.4      5.4                  15           2.4                     5.9  15
+
+     208-230 60 Single 14.7-14 33.1                     40           9.4-8.5 40.2                 45
+
+3.0  208-230  60  Three   9.4-8.5  21.1                 25           9.4-8.5 23.2                 25
+       460    60  Three     4.2    9.5                                                            15
+                                                        15           4.2               10.5
+
+       575 60 Three       3.3      7.4                  15           3.3                     8.2  15
+
+     208-230 60 Three 14.5-13.4 32.6                    45           14.5-13.4 35.9               45
+
+5.0 460 60 Three          6.7      15.1                 20           6.7               16.6       20
+
+       575 60 Three       5.3      11.9                 15           5.3               13.1       15
+
+Specifications may be subject to change without notice.
+
+100 RENEWAIRE.COM 1.800.627.4499
+                                                                       HE4XINV Energy Recovery Ventilator Standard with Bypass Economizer
+
+                                                                       5" Typ.                             34 1/8" Minimum                                                     42" X 14" Bypass Duct Connection                                ABBREVIATIONS
+                                                                                                                Service Area                                               (Direct Mount to Damper, By Others)                                 EA: Exhaust Air to outside
+                                                                                                                                                                                                                                               OA: Outside Air intake
+                                                                                                                                             Door                                                      BP                                      RA: Room Air to be exhausted
+                                                                                                                                             Swing                                                                                             FA: Fresh Air to inside
+                                                                       51 3/8" Overall                                                                 42 1/2" Minimum        RA                                       OA                      BP: Bypass Air Intake
+                                                                              35 1/8"                                                                     Service Area         Face                                         Bypass             INSTALLATION ORIENTATION
+                                                                                  Case                                                                                     Damper                                           Damper             Unit must be installed in orientation
+                                                                                                                                                                                                                                               shown.
+                                                                                                                                                                              FA                                        EA                     NOTE
+                                                                                                                                                                                                                                               1. UNLESS OTHERWISE SPECIFIED,
+                                                                       5" Typ.                                                                                             BYPASS AIRFLOW SCHEMATIC                                            DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                               NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                           FRONT VIEW                                          2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                               TO CHANGE WITHOUT NOTICE.
+                                                                                           TOP VIEW                                                                                                                                            3. MIN. DUCT CLEARANCE
+                                                                                                                                                                                                                                               FROM DAMPER BLADE WHEN FULLY
+                                                                                      Isolation Damper                                                                                                                                         OPENED TO BE 2". SMACNA RULES
+                                                                                      (Optional)                                                                                                                                               APPLY.
+                                                                                      Acts as Face Damper                                                                                                                                      4. UNITS WITH BYPASS WILL REQUIRE
+                                                                                      For Bypass Units                                                                                                                                         ADDITIONAL SPACE FOR THE
+                                                                                                                                                                                                                                               CONNECTION OF THE BYPASS DUCT
+                                                                                                   1 5/8"                                                                                                                                      (BY OTHERS).
+                                                                                                                                                                                                                                               5. FOR INSTALLATION DETAILS, REFER
+                                                                          Bypass                                                                                                                                                               TO I&O MANUAL SUPPLEMENT FOR
+                                                                       Location                                                                                                                                                                BYPASS.
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 101                                      RA Inlet                                           5" Damper              Pressure Ports         OA Damper               81 7/8" Overall    OA Inlet
+                                                                                                           42" X 14"                                         Frames Typ.             (4) Typ.               Location                 81 1/2" Case      42" X 14"
+                                                                                                           Duct Receiving                                                                                   (Optional)                                 Duct Receiving
+                                                                                                           Flange                                                      RA                 OA                                                           Flange
+
+                                                                                                                                       25 5/8" Wiring         E-Box                                                                                     1 5/8"
+
+                                                                       46 5/8"                                                                         Disconnect                                     BP      42" X 14"4"
+                                                                             10 1/8" Typ.                                                                     Switch                                    EA       Bypass                                                            28"
+                                                                                                                                                                     FA                                                                                                                  46 5/8"
+                                                                                                                                                                                                              Damper                                                                          58" Case
+                                                                                                                                                                                                              Location                                                                            62" Overall
+                                                                                                                                                                                                            (Optional)
+
+                                                                                           37 3/4" Typ.      CL 8"                                                               CL 5 5/8" Power In                                 34" X 12"  5 1/4"
+                                                                                                           Wiring                                                               CL 2 1/2" Control In                     Duct Receiving
+                                                                                                                                                                                (2) 7/8" Holes for
+                                                                                                                                                                                Wiring in Bottom                               Flange Typ.
+                                                                                                                                                                                of E-Box
+                                                                                                   LEFT VIEW                                                                                                                        RIGHT VIEW
+                                                                       MAoIRdFeLlO: HWE4CXOINNFVIG[BUyRpAaTIsOs]N                                                          FRONT VIEW
+                                                                       DArvaaiwlabilenags sThyowpnein:dUimnenitsioDn idmraweinng.sion                                                                                                              UNIT MOUNTING & APPLICATION
+                                                                       Version: MAY18                                                                                                                                                              Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                                                                                   be switched.
+
+                                                                                                                                                                                                      HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 4XRT                                                              Energy Recovery Ventilator
+                                                                     Standard
+
+ROOFTOP UNIT                                                         SPECIFICATIONS
+
+Download specification at:                                           Ventilation Type:                                                 Options:
+renewaire.com/specifications                                         Static plate, heat and humidity transfer                          Onboard variable frequency drives (VFDs) -
+
+AIRFLOW PERFORMANCE                                                  Typical Airflow Range: 1,000-4,400 CFM                                one or both airstreams
+                                                                                                                                       Shaft grounding ring on motors with VFDs
+                                                                     AHRI 1060 Certified Core: Four L125-G5                             Fused disconnect
+                                                                                                                                       Integrated programmable controls -
+                                                                     Standard Features:
+                                                                     TEFC Premium efficiency motors                                        enhanced, premium
+                                                                     Motor starters                                                    Class 1 low leakage motorized isolation dampers -
+                                                                     Non-fused disconnect
+                                                                     24 VAC transformer/relay package                                     OA, RA or both airstreams
+                                                                     Cross-core differential pressure ports                            Qty. 2, Factory mounted filter alarms -
+
+                                                                     Filters:                                                             both airstreams
+                                                                     Total qty. 8, MERV 8: 20" x 20" x 2"                              Double wall construction
+                                                                                                                                       Exterior paint - white, custom colors
+                                                                     Unit Dimensions & Weight:
+                                                                     94" L x 83" W x 44" H                                             Accessories:
+                                                                     845-1,143 lbs., varies by option(s)                               Filters - MERV 13, 2" (shipped loose)
+                                                                                                                                       Roof curb - standard 14"
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                    Curb wind clip
+                                                                     80" L x 90" W x 67" H                                             Engineered combo curb for Carrier RTU
+                                                                     1,279 lbs.                                                        Engineered combo curb for Trane RTU
+                                                                                                                                       Digital time clock - wall mount (TC7D-W),
+                                                                     Motor(s):
+                                                                     Qty. 2, Belt drive blower/standard motor packages                    in exterior enclosure (TC7D-E)
+                                                                                                                                       Carbon dioxide sensor/control -
+                                                                        with adjustable sheaves (see table below)
+                                                                                                                                          wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                       IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                          duct mount (IAQ-D)
+                                                                                                                                       Motion occupancy sensor/control -
+
+                                                                                                                                          ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                       Smoke Detector - duct mount (SD-D)
+                                                                                                                                       Electric duct heater - EK series (1–175 kW));
+
+                                                                                                                                          designed for indoor ductwork installation only
+                                                                                                                                       Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                          (50-400 MBH), installed downstream of any fans
+
+Motor  Blower       Sheave                                                                   External Static Pressure (in. w.g.)
+ HP     RPM           Adj.
+                     Turns         0.00                 0.25                           0.50           0.75                             1.00             1.25        1.50
+        1186         Open   SCFM BHP
+                            3099 1.5                    SCFM BHP SCFM BHP SCFM BHP SCFM BHP                                                       SCFM BHP SCFM BHP
+                       4                                2790 Th1e.3rmal P2e2r9fo5rmanc1e.1Rating1s79G05 20150..28.xlsx 1150                             4 Cores (IOM)
+                                                                                                                                             0.6
+
+2.0           1326  2       3465 2.2 3185 1.9 2810 1.7 2335 1.4 1885 1.2 1290 0.9
+
+              1466  0                                                                                                             2451 1.8 2026 1.5 1485 1.2
+
+              1455  4       3812 2.7 3550 2.5 3285 2.3 2820 2.0 2400 1.7 1970 1.5 1450 1.2
+
+              1527  3                                   3750 2.9 3500 2.7 3085 2.4 2676 2.1 2300 1.9 1815 1.5
+
+3.0           1598  2                                                                             3350 2.6 2950 2.6 2590 2.3 2175 2.0
+
+              1670  1                                                                                                             3210 3.0 2870 2.7 2500 2.4
+
+              1742  0                                                                                                                                               2800 2.9
+
+              1623  4       4165 3.7 3965 3.5 3750 3.3 3475 3.0 3055 2.5 2685 2.3 2290 2.0
+
+5.0           1728  2                                   4240 4.3 4050 4.0 3820 3.7 3450 3.3 3050 3.0 2720 2.6
+
+              1832  0                                                                  4345 4.9 4140 4.5 3850 4.2 3490 3.7 3145 3.3
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.  Operation in this zone will likely exceed FLA limits.                   Operation in this zone outside of core airflow limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                CORE PERFORMANCE
+
+              Standard Electrical Specifications                       Optional Factory Installed                                                  Airflow (CFM)
+                                                                     VFD Electrical Specifications
+
+                                                        Max.                                      Max.                                1000        2000        3000  4000
+                                                                                                                                  90%
+HP     Volts  HZ    Phase      FLA     Min. Cir.        Overcurrent     FLA            Min. Cir.  Overcurrent  Effectiveness (%)
+                            per motor   Amps            Protection   per motor          Amps      Protection
+
+                                                        Device                                    Device
+
+2.0 120 60 Single 20.0                 45.0             60                                                                        70%
+
+     208-230 60 Single 10.8-10.0 24.3                   35           6.6-5.8 28.3                 30                              50%
+
+2.0  208-230  60    Three   6.6-5.8    14.9             20           6.6-5.8 16.3                 20                              30%
+       460    60    Three     2.9      6.5                                                        15                                      At AHRI 1060 standard conditions.
+                                                        15           2.9               7.2                                                See all AHRI certified ratings at www.ahrinet.org.
+
+       575 60 Three 2.4                5.4              15           2.4               5.9        15
+
+     208-230 60 Single 14.7-14 33.1                     40           9.4-8.5 40.2                 45
+
+3.0  208-230  60    Three   9.4-8.5    21.1             25           9.4-8.5 23.2                 25
+       460    60    Three     4.2      9.5                                                        15
+                                                        15           4.24              10.5
+
+       575 60 Three 3.3                7.4              15           3.3               8.2        15
+
+     208-230 60 Three 14.5-13.4 32.6                    45           14.5-13.4 35.9               45
+
+5.0 460 60 Three 6.7                   15.1             20           6.7               16.6       20
+
+       575 60 Three 5.3                11.9             15           5.3               13.1       15
+
+Specifications may be subject to change without notice.
+
+102 RENEWAIRE.COM 1.800.627.4499
+                                                                       HE4XRT (RTV/RTR) Energy Recovery Ventilator Standard
+
+                                                                       Ty1p.1/8"                        RA          RA                                                                                                                                             ABBREVIATIONS
+                                                                                                        10" X 52"   Damper Location                                                                                                                                EA: Exhaust Air to outside
+                                                                                                        Opening     (Optional)                                                                                                   CURB 4X                           OA: Outside Air intake
+                                                                                              31"                   (Recessed 3/4")                                                                                                                                RA: Room Air to be exhausted
+                                                                                                                                                                                                                                    76 1/2" O.D.                   FA: Fresh Air to inside
+                                                                                                                                           33 5/8"                                                                              54 1/4"                            RTV: Rooftop Vertical RA & FA
+                                                                                                                                         Minimum                                                                                 RA                                RTR: Rooftop Vertical RA Only
+                                                                                                                                      Service Area
+                                                                       2 1T/y8p" .                                                                                                                      13 1/4"A                                                   INSTALLATION ORIENTATION
+                                                                                                                                                                                                                                                                   Unit must be installed in orientation
+                                                                                                                                                                                                                                                                   shown.
+
+                                                                                                                                                                                                                                                                   NOTE:
+                                                                                                                                                                                                                                                                   1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                       Door                                                                                                        DIMENSIONS ARE ROUNDED TO THE
+                                                                       57 3/8" Case                                                                    Swing        67 5/8" Minimum       50 3/8" I.D.                                               54 1/8" O.D.  NEAREST EIGHTH OF AN INCH.
+                                                                            47 7/8"                                                                                    Service Area                                                               A
+                                                                                 17"
+                                                                                                                                                                                                                                                                   2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                        13 5/8"                                                                                                                                                    TO CHANGE WITHOUT NOTICE.
+
+                                                                                                                                       Door                                                                                               FA                       CURB CROSS-SECTION A-A (TYP.)
+                                                                                                                                       Swing                                                                                               34"
+                                                                                                                                                                                                                            72 3/4" I.D.
+                                                                                                                                                                                                        14 3/4"                                      4 5/8"        1 1/2" X 1/4"               1 7/8"
+                                                                                                                                                                                                                           TOP VIEW                                Neoprene Gasket
+
+                                                                       FA (RTV)                                           16 1/8"                      10 1/8"                                                                                                     3/4" X 3 1/2"
+                                                                       (2) 6 7/8" X 11"                             36 5/8"
+                                                                       Openings                                                                                                                                                                                    Wooden Nailer                       14"
+                                                                                                                                                                                                                                                                                           3"
+
+                                                                                              TOP VIEW                                                                                                                                                             SECTION A-A
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 103                         EA Outlet                                                                                                              93 7/8" Overall                                 82 7/8" Overall                   OA
+                                                                                                                                                                                                                                                                       81 3/8" Case                    Damper
+                                                                                                                                                                                                                          54 1/2"                                                                      Location
+                                                                                                                                                                                                                       Lifting Lugs                                79 1/8" Lifting Lugs                (Optional)
+
+                                                                                                                                       12 3/4" Wiring               E-Box            2"                                                           Pressure Ports
+                                                                                                                                                                                                                                                  (4) Typ.
+                                                                       44" Overall                                                                                  EA
+                                                                              37 3/8" Case                                                                                                                                                           OA
+
+                                                                                      6 1/8"                                                                        FA   RTR
+                                                                                                                                                                        ONLY
+
+                                                                                              38 7/8"               CL 5 1/4"                             Disconnect                                                 FA
+                                                                                                  FA (RTR)            Wiring                                     Switch                                               RTV
+                                                                       3 5/8"                                                                                                                                        ONLY  RA
+                                                                                                        32" X 12"                                      CL 5 3/4" Power In
+                                                                                              Duct Receiving
+                                                                                                                                                       CL 2 5/8" Control In
+                                                                                                          Flange                                       (2) 7/8" Holes
+                                                                                                                                                       for wiring in bottom
+                                                                                                                                                       of E-Box
+                                                                                                                               HERT except 6x 8x, LERT                  HERT except 6x 8x, LERT
+                                                                                                         LEFT VIEW
+                                                                                                                                                                                                                     FRONT VIEW                                    RIGHT VIEW
+
+                                                                       MoAIdReFlL: OHWE4CXORNTVFI/GRUTRRATION                      RTV                                               RTR                                                                                UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                                                                                                        Must be mounted as shown. Airstreams can not
+                                                                       DrAavawilaibnlegasTsyhopwen:: Unit Dimension EA                                          OA  EA                                           OA                                                     be switched.
+
+                                                                       Version: MAY18                                                                                   FA
+
+                                                                                                                                   FA   RA                                           RA
+
+                                                                                                                                                                                                                                      HE-SERIES
+                                                                                                                                                                                                                                                                                                                                     SPECIFICATIONS & DIMENSIONS
+
+                                    2 1T/y8p" .
+104 RENEWAIRE.COM 1.800.627.4499
+HE4XRT (RTH/RTF) Energy Recovery Ventilator Standard
+
+Typ1. 1/8"                                                                                                                                                                                      ABBREVIATIONS
+                                                                                                                                                                                                EA: Exhaust Air to outside
+                                                                                                                                                       CURB 4X                                  OA: Outside Air intake
+                                                                                                                                                                                                RA: Room Air to be exhausted
+                                                                                                                                                          76 1/2" O.D.                          FA: Fresh Air to inside
+                                                                                                                                                      54 1/4"                                   RTF: Rooftop Vertical FA Only
+                                                                                                                                                       RA                                       RTH: Rooftop Horizontal RA & FA
+                                                                                                                                     A
+                                                              33 5/8"                                                         13 1/4"                                                           INSTALLATION ORIENTATION
+                                                            Minimum                                                                                                       FA                    Unit must be installed in orientation
+                                                          Service Area                                                                                                    34"                   shown.
+                                                                                                                                                           72 3/4" I.D.
+                                                              Door                                                                                                                              NOTE:
+                                                              Swing                                                                                   TOP VIEW                                  1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                DIMENSIONS ARE ROUNDED TO THE
+57 3/8" Case                                                                                67 5/8" Minimum     50 3/8" I.D.                                                      54 1/8" O.D.  NEAREST EIGHTH OF AN INCH.
+          17"                                                                                  Service Area                                                                    A
+
+                                 13 5/8"                                                              FA                                                                                        2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                TO CHANGE WITHOUT NOTICE.
+
+                                                          Door                                                                                                                                  CURB CROSS-SECTION A-A (TYP.)
+                                                          Swing
+
+                                                                                                                              14 3/4"                                             4 5/8"        1 1/2" X 1/4"               1 7/8"
+                                                                                                                                                                                                Neoprene Gasket
+
+FA (RTF)                                         16 1/8"                  10 1/8"                                                                                                               3/4" X 3 1/2"
+(2) 6 7/8" X 11"                           36 5/8"
+Openings                                                                                                                                                                                        Wooden Nailer                       14"
+                                                                                                                                                                                                                        3"             6"
+
+                     TOP VIEW                                                                                                                                                                   SECTION A-A
+
+                     EA Outlet                                                                                                             93 7/8" Overall                                        82 7/8" Overall                        OA
+                                                                                                                                                                                                    81 3/8" Case                         Damper
+                                                                                                                                                54 1/2"                                                                                  Location
+                                                                                                                                             Lifting Lugs                                       79 1/8" Lifting Lugs                     (Optional)
+
+                                                          12 3/4" Wiring               E-Box                    2"                                                             Pressure Ports
+                                                                                                                                                                               (4) Typ.
+44" Overall                                                                            EA
+    37 3/8" Case                                                                                                                                                                  OA
+
+             6 1/8"                                                                    FA    RTH                                                                                  RA
+                                                                                            ONLY
+                                                                                                                                                                               5" Damper
+3 5/8"               38 7/8"               CL 5 1/4"                         Disconnect                                                    FA                                  Frames Typ.      RA                                   19 1/4"
+                         FA (RTH)            Wiring                                 Switch                                                                                                      42" X 14"
+                                                                                                                                            RTF                                                 Duct Receiving              RA
+                               32" X 12"                                  CL 5 3/4" Power In                                               ONLY                                                 Flange                      Damper Location
+                     Duct Receiving                                                                                                                                                                                         (Optional)
+                                                                          CL 2 5/8" Control In                                             FRONT VIEW
+                                 Flange                                   (2) 7/8" Holes
+                                                                          for wiring in bottom
+                                                                          of E-Box
+                                                      HERT except 6x 8x, LERT               HERTexcept 6x 8x, LERT
+                                LEFT VIEW
+                                                                                                                                                                                                RIGHT VIEW
+
+MoAIdReFlL:OHWE4CXORNTHFI/GRUTRF ATION                              RTH                                    RTF                                                                                                  UNIT MOUNTING & APPLICATION
+DrAavawilaibnlegasTsyhopwen:: Unit Dimension          EA
+Version: MAY 18                                                                    OA  EA                                              OA                                                                       Must be mounted as shown. Airstreams can not
+                                                         FA                                                                            RA                                                                       be switched.
+                                                                                   RA
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
+
+                                                                      FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 105
+SPECIFICATIONS & DIMENSIONS
+
+HE 4XRTC                                                                 Energy Recovery Ventilator
+                                                                         Standard
+
+ROOFTOP UNIT                                                             SPECIFICATIONS
+Direct Connect
+
+Download specification at:                                               Ventilation Type:                                                   Options:
+renewaire.com/specifications                                             Static plate, heat and humidity transfer                            Onboard variable frequency drives (VFDs) -
+
+                                                                         Typical Airflow Range: 2,500-3,900 CFM                                  one or both airstreams
+                                                                                                                                             Shaft grounding ring on motors with VFDs
+                                                                         AHRI 1060 Certified Core: Four L125-G5                               Fused disconnect
+                                                                                                                                             Integrated programmable controls -
+                                                                         Standard Features:
+                                                                         TEFC Premium efficiency motors                                          enhanced, premium
+                                                                         Motor starters                                                      Qty. 2, Factory mounted filter alarms -
+                                                                         Non-fused disconnect
+                                                                         24 VAC transformer/relay package                                       both airstreams
+                                                                         Cross-core differential pressure ports                              Double wall construction
+                                                                                                                                             Exterior paint - white, custom colors
+                                                                         Filters:
+                                                                         Total qty. 8, MERV 8: (4) 20" x 20" x 2" and                        Accessories:
+                                                                                                                                             Filters - MERV 13, 2" (shipped loose)
+                                                                            (4) 16" x 20" x 2"                                               RTC transition kit - for vertical RTU, for horizontal RTU
+                                                                                                                                             Rooftop RTC transition paint - white, custom colors
+                                                                         Unit Dimensions & Weight:                                           Digital time clock - wall mount (TC7D-W),
+                                                                         81 1/4" L x 83 1/4" W x 48 1/4" H
+                                                                         887-1,169 lbs., varies by option(s)                                    in exterior enclosure (TC7D-E)
+                                                                                                                                             Carbon dioxide sensor/control -
+                                                                         Max. Shipping Dimensions & Weight (on pallet):
+                                                                         80" L x 90" W x 80" H                                                  wall mount (CO2-W), duct mount (CO2-D)
+                                                                         1,300 lbs.                                                          IAQ sensor - wall mount (IAQ-W),
+
+                                                                         Motor(s):                                                              duct mount (IAQ-D)
+                                                                         Qty. 2, 5.0 HP ea., Belt drive blower/standard motor                Motion occupancy sensor/control -
+
+                                                                            packages with adjustable sheaves                                    ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                             Smoke Detector - duct mount (SD-D)
+
+AIRFLOW PERFORMANCE                                                      Note: Electric Duct Heater and Indirect Gas-Fired Duct Furnace are not available on RTC units.
+
+                                                               Tie-In Directly to Rooftop A/C Unit*                                          Unit Ducted Independently*
+
+             Blower RPM Sheave Adj.                            Static Pressure in Adjacent Air Handler               External Static Pressure (Inches Water Column)
+               Nominal Turns Open
+                                                                 (Inches Water Column)
+
+                                                          -0.75             -0.5              -0.25                   0.0                         +0.25       +0.5            +0.75
+                                                                                                                CFM BHP                      CFM BHP     CFM BHP         CFM BHP
+                                                    CFM BHP CFM BHP CFM BHP
+
+             1510                        0          3400 3.1 3700 3.3 4000 3.6 4250 4.1 4000 3.6 3700 3.3 3400 3.1
+
+             1465                        1          3275 3.0 3600 3.2 3925 3.4 4225 3.8 3925 3.4 3600 3.2 3275 3.0
+
+             1420                        2          3125 2.8 3450 2.9 3775 3.0 4156 3.6 3775 3.0 3450 2.9 3125 2.8
+
+Exhaust Air  1375                        3          2935 2.3 3300 2.5 3665 2.8 4067 3.4 3665 2.8 3300 2.5 2935 2.3
+
+             1330                        4          2780 2.0 3150 2.3 3520 2.5 3900 3.1 3520 2.5 3150 2.3 2780 2.0
+
+             1285                        5          2685 1.6 T3h0e5r0mal Pe2.r0forma3n4c1e5 Ratin2g.4s G5 23071605.2.xls2x.8 3415 2.4 30450Cores2.(0IOM) 2685 1.6
+
+             1240                        6          2620 1.4 2950 1.7 3280 2.0 3600 2.4 3280 2.0 2950 1.7 2620 1.4
+
+             1825                        0                                                                                                                               3245 5.0
+
+             1770                        1                                                                                                               3225 4.9 3125 4.6
+
+             1715                        2                                                                      3450 4.8 3275 4.6 3140 4.5 3005 4.3
+
+Fresh Air    1660                        3          3920 5.0 3760 5.0 3600 5.0 3360 4.5 3180 4.1 3060 4.0 2940 3.9
+
+             1605                        4          3790 4.6 3670 4.6 3550 4.7 3270 4.1 3090 3.7 2970 3.7 2850 3.7
+
+                 1550                    5          3724 4.2 3582 4.3 3440 4.5 3190 3.6 3010 3.4 2890 3.3 2770 3.3
+
+                 1495                    6          3680 4.2 3500 4.1 3320 3.9 3100 3.5 2910 2.9 2790 2.8 2670 2.8
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.         Operation in this zone will likely exceed FLA limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+* See page 38 for installation details.
+
+ELECTRICAL DATA                                                                                                      CORE PERFORMANCE
+
+             Standard Electrical Specifications                               Optional Factory Installed                                           Airflow (CFM)
+                                                                            VFD Electrical Specifications
+
+                                                                 Max.                                   Max.                                1000  2000   3000            4000
+                                                                                                                                        90%
+HP  Volts    HZ  Phase                      FLA     Min. Cir.  Overcurrent     FLA     Min. Cir.        Overcurrent  Effectiveness (%)
+                                         per motor   Amps      Protection   per motor   Amps            Protection
+
+                                                                 Device                                 Device                          70%
+
+    208-230 60 Three 14.5-13.4 32.6                              45         14.5-13.4 35.9              45
+
+5.0 460 60 Three 6.7                                15.1         20         6.7         16.6            20                              50%
+
+    575 60 Three 5.3                                11.9         15         5.3         13.1            15
+
+Specifications may be subject to change without notice.                                                                                  30%
+                                                                                                                                                 At AHRI 1060 standard conditions.
+
+                                                                                                                                                 See all AHRI certified ratings at www.ahrinet.org.
+
+106 RENEWAIRE.COM 1.800.627.4499
+                                                                       HE4XRTC Energy Recovery Ventilator Standard
+
+                                                                       1/8"                                                                                                                                                                              ABBREVIATIONS
+                                                                                                                                                                                                                                                         EA: Exhaust Air to outside
+                                                                       1                                                                                                                                                                                 OA: Outside Air intake
+                                                                         Typ.                                                                                                                                                                            RA: Room Air to be exhausted
+                                                                                                                                                                                                                                                         FA: Fresh Air to inside
+                                                                                           2 1T/y8p" .                                                             33 7/8" Minimum                                                                       INSTALLATION ORIENTATION
+                                                                                                                                                                   Service Area                                                                          Unit must be installed in orientation
+                                                                                                                                                                                                                                                         shown.
+                                                                       57 3/8" Case                                                                         Door                                                                                         NOTE:
+                                                                                                                                                            Swing                                                                                        1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                  10 1/8"                                                                                                DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                     67 5/8" Minimum                                                                     NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                         Service Area                                                                    2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                         TO CHANGE WITHOUT NOTICE.
+
+                                                                                                                                             Door
+                                                                                                                                             Swing
+
+                                                                       17 1/2"
+                                                                            23 5/8"
+
+                                                                                                        TOP VIEW
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 107                                   79 1/8"                                                                           81 1/4" Overall                          11 1/4" Typ.          83 1/4" Overall
+                                                                                                                                                                                                       54 1/2"                                             81 1/4" Case
+                                                                                                        Lifting Lugs                                                                                               Pressure Ports
+                                                                                                                                                                                                     Lifting Lugs  (4) Typ.
+                                                                                           OA Inlet     EA Outlet
+                                                                                                                                                                                                                     FA
+                                                                       48 1/4" Overall                                                       5 1/2" Wiring         E-Box                                                RA
+                                                                             45 1/4" Case
+                                                                                                                                                                     EA
+
+                                                                                                                                                                             OA                                                    25 5/8"
+
+                                                                                                                                  CL 8 3/4"                        Disconnect                                                                            37" Typ.  39 7/8" Typ.
+                                                                                                                                     Wiring                               Switch
+                                                                                                                                                                                                                                                 6 5/8"
+                                                                                                          LEFT VIEW                                                 CL 5 3/4" Power In
+                                                                          AIRFLOW CONFIGURATION                                                                     CL 2 5/8" Control In
+                                                                                                                                                                    (2) 7/8" Holes
+                                                                       MAovdailaeblle: aHs Esh4owXnRinTCdimension drawing.                                          for Wiring in
+                                                                       Drawing Type: Unit Dimension                                                                 Bottom of E-Box
+                                                                       Version: MAY18
+                                                                                                                                                                                          FRONT VIEW                                                          RIGHT VIEW
+
+                                                                                                                                                                                                                                                         UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                                                                                         Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                                                                                         be switched.
+
+                                                                                                                                                                                          HE-SERIES
+SPECIFICATIONS & DIMENSIONS                                          Energy Recovery Ventilator                                                  For safety listed products,
+                                                                     Standarrdd & Bypass Economizer Option                                         see LE-SERIES models.
+HE 6XIN
+                                                                     SPECIFICATIONS
+INDOOR UNIT
+                                                                     Ventilation Type:                                                 Options:
+Download specification at:                                           Static plate, heat and humidity transfer                          Onboard variable frequency drives (VFDs) -
+renewaire.com/specifications
+                                                                     Typical Airflow Range: 1,500-6,500 CFM                                one or both airstreams
+                                                                                                                                       Shaft grounding ring on motors with VFDs
+                                                                     AHRI 1060 Certified Core:                                          Fused disconnect
+                                                                     Six L125-G5                                                       Integrated programmable controls -
+
+                                                                     Standard Features:                                                   enhanced, premium
+                                                                     TEFC Premium efficiency motors                                     Bypass economizer damper
+                                                                     Motor starters
+                                                                     Non-fused disconnect                                                 (see bypass DIM drawing) -
+                                                                     24 VAC transformer/relay package                                     dry-bulb temperature controls (standard),
+                                                                     Cross-core differential pressure ports                               enthalpy controls (option)
+                                                                                                                                       Class 1 low leakage motorized isolation dampers -
+                                                                     Filters:                                                             OA, EA or both airstreams
+                                                                     Total qty. 12, MERV 8: 20" x 20" x 2"                             Qty. 2, Factory mounted filter alarms -
+                                                                                                                                          both airstreams
+                                                                     Unit Dimensions & Weight:                                         Double wall construction
+                                                                     88" L x 113 1/2" W x 81 3/4" H                                    Exterior paint - white, custom colors
+                                                                     2,235-3,099 lbs., varies by option(s)
+                                                                                                                                       Accessories:
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                    Filters - MERV 13, 2" (shipped loose)
+                                                                     116" L x 90" W x 90" H                                            Digital time clock - wall mount (TC7D-W),
+                                                                     3,439 lbs.
+                                                                                                                                          in exterior enclosure (TC7D-E)
+                                                                     Motor(s):                                                         Carbon dioxide sensor/control -
+                                                                     Qty. 2, Belt drive blower/standard motor packages
+                                                                                                                                          wall mount (CO2-W), duct mount (CO2-D)
+                                                                        with adjustable sheaves (see table below)                      IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                          duct mount (IAQ-D)
+                                                                                                                                       Motion occupancy sensor/control -
+
+                                                                                                                                          ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                       Smoke Detector - duct mount (SD-D)
+                                                                                                                                       Electric duct heater - EK series (1–175 kW)
+                                                                                                                                       Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                          (50-400 MBH), installed downstream of any fans
+
+AIRFLOW PERFORMANCE
+
+Motor  Blower     Sheave       0.00                                                                         External Static Pressure (in. w.g.)      1.50 6 Cores1.(7I5OM)       2.00
+ HP     RPM         Adj.  CFM BHP                                                                                                                CFM BHP CFM BHP            CFM BHP
+                   Turns  5005 3.2                                  0.25 Therm0a.5l0Performanc0e.7R5atings G5 21.00105.2.xlsx 1.25               3750 2.8 3400 2.7          3100 2.5
+ 5.0    1460       Open   5550 4.2                              CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP                                          4500 3.8 4250 3.7          4000 3.6
+        1610                                                    4800 3.2 4650 3.1 4475 3.0 4200 2.9 4000 2.8                                     5050 4.8 4800 4.6          4600 4.5
+ 7.5    1725        4.5   5275 3.7                              5375 4.2 5250 4.1 5100 4.1 4900 4.0 4650 3.9                                     4125 3.3 3875 3.2          3575 3.1
+        1560              5950 5.0                                                                                                               4950 4.7 4750 4.6          4525 4.5
+        1740         2    6500 6.5                                                                    5525 5.0 5475 5.0 5200 4.9                 5625 6.1 5410 6.1          5300 6.0
+        1865                                                    5200 3.6 4900 3.5 4775 3.5 4550 3.4 4350 3.3
+                     0                                          5825 5.0 5625 4.9 5490 4.9 5325 4.8 5125 4.7
+                                                                6350 6.5 6225 6.4 6125 6.4 5910 6.3 5825 6.2
+                    4.5
+
+                     2
+
+                     0
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.          Operation in this zone will likely exceed FLA limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                     CORE PERFORMANCE
+
+       Standard Electrical Specifications                                      Optional Factory Installed                                  Airflow (CFM)
+                                                                             VFD Electrical Specifications
+                                                                                                                              1000 2000 3000 4000 5000 6000 7000
+HP Volts HZ Phase            FLA     Min. Cir.                      Max.     FLA per        Min. Cir.      Max.         90%Effectiveness (%)
+                          per motor   Amps                      Overcurrent   motor          Amps      Overcurrent
+                                                                Protection                             Protection       70%
+                          14.5-13.4    32.6
+                             6.7       15.1                        Device                                 Device        50%
+                             5.3       11.9
+      208-230 60  Three                                              45      14.5-13.4 35.9            45               30%
+5.0 460 60        Three   21.0-19.0    47.3                          20                                                         At AHRI 1060 standard conditions.
+                  Three      9.5       21.4                          15                6.7  16.6       20                       See all AHRI certified ratings at www.ahrinet.org.
+         575 60              7.6       17.1
+                  Three                                              60                5.3  13.1       15
+      208-230 60  Three                                              25
+7.5 460 60        Three                                              20      21.0-19.0 52.0            60
+
+         575 60                                                                        9.5  23.5       25
+
+                                                                                       7.6  18.8       20
+
+        Specifications may be subject to change without notice.
+108 RENEWAIRE.COM 1.800.627.4499
+HE6XIN Energy Recovery Ventilator Standard
+
+                                                                                                           OA34 3/4"                                                                    ABBREVIATIONS
+                                                                                           RAMinimum                                                                                    EA: Exhaust Air to outside
+                                                               Service Area                                                                                                             OA: Outside Air intake
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 109                                                                                                                   RA: Room Air to be exhausted
+                                                               34 3/4"  Minimum     Area  Door                                                112 5/8"                                  FA: Fresh Air to inside
+                                                                           Service        Swing                                                  Case                                   INSTALLATION ORIENTATION
+                                                                                                                                                       113 1/8"                         Unit must be installed in orientation
+                                                                                          FA                                    EA                        Overall                       shown.
+                                                                                                                                                                                        NOTE
+                                                                        62"                                                                                                             1.ALL UNITS HAVE INTERNAL EA
+                                                                                                                                                                                        BACKDRAFT DAMPER.
+                                                                                                                                                                                        UNLESS AN EA MOTORIZED ISOLATION
+                                                                                                                                                                                        DAMPER IS SPECIFIED.
+                                                                                                                                                                                        2.UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                        DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                        NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                        3.SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                        TO CHANGE WITHOUT NOTICE.
+
+                                                               39 1/4"                           Door        Door                             69 1/4"
+                                                                  Minimum                        Swing       Swing
+                                                                      Service
+
+                                                                         Area
+
+                                                                                                                   85 5/8"                             E-Box
+                                                                                                                 Minimum                               Minimum
+                                                                                                               Service Area     36"                    Service Area
+
+         FA Blower Outlet is 16" X 22" (Nom.)                                                                TOP VIEW                           Power and Control Wiring                         24" X 36"
+             24"X36" Duct Receiving Flange is                                                                                                   Entries 7/8" Dia.                                Duct Receiving
+             also supplied. Field install only in                                                            86 1/2" Overall                     INDOOR UNITS: EA BLOWER Outlet is               Flange Typ.
+                                     location shown.                                                         75 7/8" Lift Lugs
+                                                                                                                                                         16" X 22" (Nom.) 24"X36"       85 5/8" Case
+                             102 7/8" Lift Lugs                                                                                               Duct Receiving Flange is also supplied.
+
+   Core                                                                                                                                          Field install only in location shown.
+Access
+                                                               78 1/4" Case                                                          31 3/4"
+   Door                                                            81 5/8" Overall
+
+Pressure
+Ports
+(4) Typ.
+
+2 1/4"  63 1/4"                                                10 1/4"                                      81"                                                           63 1/4"                 8 3/4"         22" Typ.
+                                                                                                                                                                                              49 5/8"
+                    LEFT VIEW                                                                    FRONT VIEW                                                     108"                       Internal OA Damper
+MAoIRdFeLl:OHWE6CXIONNFIGURATION                                                                                                                         Internal EA Motorized             Location (Optional)
+DAravawilabinlegasTsyhpowen:inUdnimitenDsiiomn deranwsiniog.n                                                                                            Damper Location (Optional)
+Version: AUG18                                                                                                                                                                              BACK VIEW
+                                                                                                                                                       RIGHT VIEW
+                                                                                                                                                                                        UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                        Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                        be switched.
+
+                                                                                                                                              HE-SERIES
+SPECIFICATIONS & DIMENSIONS                                          Energy Recovery Ventilator                                                  For safety listed products,
+                                                                     Standard with Bypass Economizer                                               see LE-SERIES models.
+HE 6XIN
+                                                                     SPECIFICATIONS
+INDOOR UNIT
+                                                                     Ventilation Type:                                                 Options:
+Download specification at:                                           Static plate, heat and humidity transfer                          Onboard variable frequency drives (VFDs) -
+renewaire.com/specifications
+                                                                     Typical Airflow Range: 1,500-6,500 CFM                                one or both airstreams
+                                                                                                                                       Shaft grounding ring on motors with VFDs
+                                                                     AHRI 1060 Certified Core:                                          Fused disconnect
+                                                                     Six L125-G5                                                       Integrated programmable controls -
+
+                                                                     Standard Features:                                                   enhanced, premium
+                                                                     TEFC Premium efficiency motors                                     Bypass economizer damper
+                                                                     Motor starters
+                                                                     Non-fused disconnect                                                 (see bypass DIM drawing) -
+                                                                     24 VAC transformer/relay package                                     dry-bulb temperature controls (standard),
+                                                                     Cross-core differential pressure ports                               enthalpy controls (option)
+                                                                                                                                       Class 1 low leakage motorized isolation dampers -
+                                                                     Filters:                                                             OA, EA or both airstreams
+                                                                     Total qty. 12, MERV 8: 20" x 20" x 2"                             Qty. 2, Factory mounted filter alarms -
+                                                                                                                                          both airstreams
+                                                                     Unit Dimensions & Weight:                                         Double wall construction
+                                                                     88" L x 113 1/2" W x 81 3/4" H                                    Exterior paint - white, custom colors
+                                                                     2,235-3,099 lbs., varies by option(s)
+                                                                                                                                       Accessories:
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                    Filters - MERV 13, 2" (shipped loose)
+                                                                     116" L x 90" W x 90" H                                            Digital time clock - wall mount (TC7D-W),
+                                                                     3,439 lbs.
+                                                                                                                                          in exterior enclosure (TC7D-E)
+                                                                     Motor(s):                                                         Carbon dioxide sensor/control -
+                                                                     Qty. 2, Belt drive blower/standard motor packages
+                                                                                                                                          wall mount (CO2-W), duct mount (CO2-D)
+                                                                        with adjustable sheaves (see table below)                      IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                          duct mount (IAQ-D)
+                                                                                                                                       Motion occupancy sensor/control -
+
+                                                                                                                                          ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                       Smoke Detector - duct mount (SD-D)
+                                                                                                                                       Electric duct heater - EK series (1–175 kW)
+                                                                                                                                       Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                          (50-400 MBH), installed downstream of any fans
+
+AIRFLOW PERFORMANCE
+
+Motor  Blower     Sheave       0.00                                                                         External Static Pressure (in. w.g.)      1.50 6 Cores1.(7I5OM)       2.00
+ HP     RPM         Adj.  CFM BHP                                                                                                                CFM BHP CFM BHP            CFM BHP
+                   Turns  5005 3.2                                  0.25 Therm0a.5l0Performanc0e.7R5atings G5 21.00105.2.xlsx 1.25               3750 2.8 3400 2.7          3100 2.5
+ 5.0    1460       Open   5550 4.2                              CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP                                          4500 3.8 4250 3.7          4000 3.6
+        1610                                                    4800 3.2 4650 3.1 4475 3.0 4200 2.9 4000 2.8                                     5050 4.8 4800 4.6          4600 4.5
+ 7.5    1725        4.5   5275 3.7                              5375 4.2 5250 4.1 5100 4.1 4900 4.0 4650 3.9                                     4125 3.3 3875 3.2          3575 3.1
+        1560              5950 5.0                                                                                                               4950 4.7 4750 4.6          4525 4.5
+        1740         2    6500 6.5                                                                    5525 5.0 5475 5.0 5200 4.9                 5625 6.1 5410 6.1          5300 6.0
+        1865                                                    5200 3.6 4900 3.5 4775 3.5 4550 3.4 4350 3.3
+                     0                                          5825 5.0 5625 4.9 5490 4.9 5325 4.8 5125 4.7
+                                                                6350 6.5 6225 6.4 6125 6.4 5910 6.3 5825 6.2
+                    4.5
+
+                     2
+
+                     0
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.          Operation in this zone will likely exceed FLA limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                     CORE PERFORMANCE
+
+       Standard Electrical Specifications                                      Optional Factory Installed                                  Airflow (CFM)
+                                                                             VFD Electrical Specifications
+                                                                                                                              1000 2000 3000 4000 5000 6000 7000
+HP Volts HZ Phase            FLA     Min. Cir.                      Max.     FLA per        Min. Cir.      Max.         90%Effectiveness (%)
+                          per motor   Amps                      Overcurrent   motor          Amps      Overcurrent
+                                                                Protection                             Protection       70%
+                          14.5-13.4    32.6
+                             6.7       15.1                        Device                                 Device        50%
+                             5.3       11.9
+      208-230 60  Three                                              45      14.5-13.4 35.9            45               30%
+5.0 460 60        Three   21.0-19.0    47.3                          20                                                         At AHRI 1060 standard conditions.
+                  Three      9.5       21.4                          15                6.7  16.6       20                       See all AHRI certified ratings at www.ahrinet.org.
+         575 60              7.6       17.1
+                  Three                                              60                5.3  13.1       15
+      208-230 60  Three                                              25
+7.5 460 60        Three                                              20      21.0-19.0 52.0            60
+
+         575 60                                                                        9.5  23.5       25
+
+                                                                                       7.6  18.8       20
+
+        Specifications may be subject to change without notice.
+110 RENEWAIRE.COM 1.800.627.4499
+HE6XIN Energy Recovery Ventilator Standard with Bypass Economizer
+
+                                                                                                                                                                                         ABBREVIATIONS
+                                                                                                                                                                                         EA: Exhaust Air to outside
+                                                                                                                                                                                         OA: Outside Air intake
+                                                                                                                                                                                         RA: Room Air to be exhausted
+                                                                                                                                                                                         FA: Fresh Air to inside
+                                                                                                                                                                                         BP: Bypass Air Intake
+                                                                                                                                                         BP34 3/4"
+                                                                           Minimum                                                                                                       INSTALLATION ORIENTATION
+                                                                                                                   OAService Area                                                        Unit must be installed in orientation shown.
+                                                                                                     RA
+                 16" X 38" Bypass Duct Connection                     34 3/4"  Minimum     Area                             16" X 38" Bypass                                             NOTE
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 111(Direct Mount to Damper, By Others)Service          Damper Location                                                 1.ALL UNITS HAVE INTERNAL EA BACKDRAFT DAMPER.
+                                                                                                                                                                                         UNLESS AN EA MOTORIZED ISOLATION DAMPER IS
+Bypass           BP                                                                                     Door                         Optional                   112 5/8" Case            SPECIFIED.
+                                                                                                        Swing                                                          116 3/4" Overall
+                                                                                                                                               5 1/8"
+Damper
+
+                                                                                                                                                                                         2.UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE
+                                                                                                                                                                                         ROUNDED TO THE NEAREST EIGHTH OF AN INCH.
+                                                                                                        FA                                     EA
+
+EA                                                                RA              62"                                                                                                    3.SPECIFICATIONS MAY BE SUBJECT TO CHANGE
+                                                                                                                                                                                         WITHOUT NOTICE.
+
+                                                Face Damper                                                                                                                              4. DAMPER SWINGS IN DIRECTION OF AIRFLOW. MIN.
+                                                                                                                                                                                         DUCT CLEARANCE FROM DAMPER BLADE WHEN
+BYPASS AIRFLOW SCHEMATIC                                                                                                                                                                 FULLY OPENED TO BE 2". SMACNA RULES APPLY.
+
+                 RIGHT VIEW                                           39 1/4"                               32 3/8"      Door        Door              69 1/4"                           5. UNITS WITH BYPASS WILL REQUIRE ADDITIONAL
+   (OA/FA Airstream Not Shown)                                           Minimum                                         Swing       Swing                                               SPACE FOR THE CONNECTION OF THE BYPASS DUCT
+                                                                             Service                                                                                                     (BY OTHERS).
+               FA Blower Outlet is 16" X 22" (Nom.)
+            24" X 36" Duct Flange is also supplied.                             Area
+
+                 Field install only in location shown.                                                                                                                                   6. FOR INSTALLATION DETAILS, REFER TO I&O
+                            102 7/8" Lifting Lugs                                                                                                                                        MANUAL SUPPLEMENT FOR BYPASS.
+                                                                                                                                 85 5/8"                        E-Box
+                                                                                                                               Minimum                          Minimum
+                                                                                                                            Service Area       36"              Service Area
+
+                                                                                                                          TOP VIEW                                                               26" X 38" RA Face
+
+                                                                                                            6 3/8" Typ.   86 5/8" Overall      Power and Control Wiring                          Damper Location
+                                                                                                                             85 5/8" Case      Entries 7/8" Dia.                                             Optional
+
+5" Typ.                                                                                                                  75 7/8" Lifting Lugs          INDOOR UNITS: EA BLOWER Outlet is                                OA Duct
+                                                                                                                                                       16" X 22" (Nom.) 24"X36" Duct Flange                             Flange
+                                                                                                                                                       is also supplied. Field install only in                          24" X 36"
+                                                                                                                                                       location shown.
+
+                                                                                                                                                                                             2"
+
+           Core                                                                   78 1/4" Case                                                 53 1/2"
+        Access                                                                         83 3/8" Overall                                                                                                          22"
+
+           Door                                                                                                                                                                                                                                            21 1/8"
+
+Pressure Ports
+(4) Typ.
+
+        6 3/8"
+         Typ.
+
+                 63 1/4"                                                                                                        81"                                                63 1/4"                   8 3/4"
+                                                                                                                                                                                                         48 3/4"
+         2 1/4"                                                       4"                                                                                                  108"                       Internal OA Damper
+                                                                         10 1/2"                                                                                Internal EA Motorized                Location (Optional)
+                                                                                                                                                                Damper Location (Optional)
+                            LEFT VIEW                                                                                    FRONT VIEW                                                                    BACK VIEW
+MAoIRdFeLl:OHWE6CXOINN[FBIyGpUaRssA]TION                                                                                                                        RIGHT VIEW
+DArvaaiwlabilne gas Tshyopwen :inUdinmietnDsioimn deranwsiniog.n                                                                                                                                 UNIT MOUNTING & APPLICATION
+Version: AUG18                                                                                                                                                                                   Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                                 be switched.
+
+                                                                                                                                               HE-SERIES
+SPECIFICATIONS & DIMENSIONS                                           Energy Recovery Ventilator                                                                       For safety listed products,
+                                                                      Standard                                                                                           see LE-SERIES models.
+HE 6XRT
+                                                                      SPECIFICATIONS                                                     Options:
+ROOFTOP UNIT                                                                                                                             Onboard variable frequency drives (VFDs) -
+                                                                      Ventilation Type:
+Download specification at:                                            Static plate, heat and humidity transfer                              one or both airstreams
+renewaire.com/specifications                                                                                                             Shaft grounding ring on motors with VFDs
+                                                                      Typical Airflow Range: 1,500-6,500 CFM                              Fused disconnect
+                                                                                                                                         Integrated programmable controls -
+                                                                      AHRI 1060 Certified Core:
+                                                                      Six L125-G5                                                           enhanced, premium
+                                                                                                                                         Class 1 low leakage motorized isolation dampers -
+                                                                      Standard Features:
+                                                                      TEFC Premium efficiency motors                                         OA, EA or both airstreams
+                                                                      Motor starters                                                     Qty. 2, Factory mounted filter alarms -
+                                                                      Non-fused disconnect
+                                                                      24 VAC transformer/relay package                                      both airstreams
+                                                                      Cross-core differential pressure ports                             Double wall construction
+                                                                                                                                         Exterior paint - white, custom colors
+                                                                      Filters:
+                                                                      Total qty. 12, MERV 8: 20" x 20" x 2"                              Accessories:
+                                                                                                                                         Filters - MERV 13, 2" (shipped loose)
+                                                                      Unit Dimensions & Weight:                                          Roof curb - standard 14"
+                                                                      106 1/2" L x 113 1/2" W x 81 3/4" H                                Curb wind clip
+                                                                      2,301-3,166 lbs., varies by option(s)                              Engineered combo curb for Carrier RTU
+                                                                                                                                         Engineered combo curb for Trane RTU
+                                                                      Max. Shipping Dimensions & Weight (on pallet):                     Digital time clock - wall mount (TC7D-W),
+                                                                      116" L x 90" W x 90" H
+                                                                      3,599 lbs.                                                            in exterior enclosure (TC7D-E)
+                                                                                                                                         Carbon dioxide sensor/control -
+                                                                      Motor(s):
+                                                                      Qty. 2, Belt drive blower/standard motor packages                     wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                         IAQ sensor - wall mount (IAQ-W),
+                                                                         with adjustable sheaves (see table below)
+                                                                                                                                            duct mount (IAQ-D)
+                                                                                                                                         Motion occupancy sensor/control -
+
+                                                                                                                                            ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                         Smoke Detector - duct mount (SD-D)
+                                                                                                                                         Electric duct heater - EK series (1–175 kW);
+
+                                                                                                                                            designed for indoor ductwork installation only
+                                                                                                                                         Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                            (50-400 MBH), installed downstream of any fans
+
+AIRFLOW PERFORMANCE
+
+                  Sheave                                                                External Static Pressure (in. w.g.)
+                    Adj.
+Motor HP  Blower   Turns       0.00                             0.25         0.50       0.75           1.00                        1.25  1.50  1.75           2.00
+           RPM     Open   CFM BHP
+                          5005 3.2                                    Thermal Performance Ratings G5 2015.2.xlsx                               6 Cores (IOM)
+                    4.5   5550 4.2                              CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP                                  CFM BHP CFM BHP CFM BHP
+
+            1460     2    5275 3.7                              4800 3.2 4650 3.1 4475 3.0 4200 2.9 4000 2.8                             3750 2.8 3400 2.7 3100 2.5
+                          5950 5.0
+5.0         1610     0    6500 6.5                              5375 4.2 5250 4.1 5100 4.1 4900 4.0 4650 3.9                             4500 3.8 4250 3.7 4000 3.6
+
+            1725    4.5                                                                 5525 5.0 5475 5.0 5200 4.9                       5050 4.8 4800 4.6 4600 4.5
+
+            1560     2                                          5200 3.6 4900 3.5 4775 3.5 4550 3.4 4350 3.3                             4125 3.3 3875 3.2 3575 3.1
+
+7.5         1740     0                                          5825 5.0 5625 4.9 5490 4.9 5325 4.8 5125 4.7                             4950 4.7 4750 4.6 4525 4.5
+
+            1865                                                6350 6.5 6225 6.4 6125 6.4 5910 6.3 5825 6.2                             5625 6.1 5410 6.1 5300 6.0
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.          Operation in this zone will likely exceed FLA limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                               Optional Factory Installed        CORE PERFORMANCE
+                     Standard Electrical Specifications                       VFD Electrical Specifications
+                                                                                                                                      Airflow (CFM)
+HP   Volts  HZ    Phase      FLA     Min. Cir.                      Max.        FLA     Min. Cir.      Max.     Effectiveness (%)
+                          per motor   Amps                      Overcurrent  per motor   Amps      Overcurrent            1000 2000 3000 4000 5000 6000 7000
+                                                                Protection                         Protection        90%
+
+                                                                   Device                             Device         70%
+
+     208-230 60 Three 14.5-13.4 32.6                                 45      14.5-13.4 35.9        45                50%
+                                                                     20
+5.0 460 60 Three 6.7                 15.1                            15      6.7        16.6       20                30%
+                                                                                                                            At AHRI 1060 standard conditions.
+     575 60 Three 5.3                11.9                            60      5.3        13.1       15                       See all AHRI certified ratings at www.ahrinet.org.
+                                                                     25
+     208-230 60 Three 21.0-19.0 47.3                                 20      21.0-19.0 52.0        60
+
+7.5 460 60 Three 9.5                 21.4                                    9.5        23.5       25
+
+     575 60 Three 7.6                17.1                                    7.6        18.8       20
+
+        Specifications may be subject to change without notice.
+112 RENEWAIRE.COM 1.800.627.4499
+                                                                       HE6XRT Energy Recovery Ventilator Standard
+
+                                                                                                      121 1/4" Minimum                                  39 1/2"                                                                                                                                          ABBREVIATIONS
+                                                                                                         Service Area                                                                                                                                                                                    EA: Exhaust Air to outside
+                                                                                                                                                                                                                                                                                                         OA: Outside Air intake
+                                                                       65 3/4" Minimum                    Door          Door                                                  FA (RTV, RTF)                                      CURB 6X                                                                 RA: Room Air to be exhausted
+                                                                          Service Area                    Swing         Swing                                                 16" X 22"                                                                                                                  FA: Fresh Air to inside
+                                                                                                                                                                                                                                  76" O.D.                                                               RTV: Rooftop Vertical RA & FA
+                                                                                                                                                                        15 3/4"                                                                36"                                                       RTF: Rooftop Vertical FA Only
+                                                                                                                                                                          135 3/4" Minimum                                                                                                               RTR: Rooftop Vertical RA Only
+                                                                                        26 1/4"                                                                              Service Area                                                                26"                                             RTH: Rooftop Horizontal RA & FA
+                                                                                                                                                                                                                                                                                                         INSTALLATION ORIENTATION
+                                                                                        71 1/2"                                                         Door                                             99 1/4" I.D.                            FA      31"  103" O.D.                                  Unit must be installed in orientation
+                                                                                                                                                        Swing                                                                                                                                            shown.
+                                                                                                                                                                                                                       A                                                                                 NOTE:
+                                                                                                                                                                                                                                                 RA                                                      1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                 36"                                                     DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                                                                         NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                   72 1/4" I.D.                                                          2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                                                                         TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                                                TOP VIEW
+                                                                                                                                                                                                                                                      A
+
+                                                                                                                                                                                                                                                                                CURB CROSS-SECTION A-A (TYP.)
+
+                                                                                                                                                                                                                                                                                                         1 1/2" X 1/4"                1 7/8"
+                                                                                                                                                                                                                                                                                                         Neoprene Gasket
+                                                                                                 19 7/8"  54 7/8"                         20" Minimum                                                                                                    26"
+                                                                                                           60 7/8"                        Service Area                                                                                                                                                   3/4" X 3 1/2"
+                                                                                                                                                                                                                                                                                                         Wooden Nailer
+                                                                                                            TOP VIEW           RA (RTV, RTR)
+                                                                                                                               24" X 34"                                                                                                                                                                                          3"
+
+                                                                                                                                                                                                                                                                                                                                              14"
+
+                                                                                                                                                                                                                                                                                                         SECTION A-A
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 113          OA Inlet                          OA Damper                              RA Inlet              Pressure                                 113 1/8" Overall                           1 1/4"                                          Disconnect
+                                                                                 Louver                          Location                               (RTH, RTF)            Ports                                                                           Typ.                                                       Switch
+                                                                                                                 (Optional)                             24" X 36"             (4) Typ.                                   109 1/2" Case                   30 1/2"
+                                                                       EA Damper                                                                        Duct Receiving                                                       102 7/8"                                                                    106" Overall
+                                                                          Location                                                                      Flange                 OA                                                                        EA Outlet
+                                                                                                                                                                                                                           Lifting Lugs                                                                  83" Case
+                                                                        (Optional)                                                                                                                                                                       FA Outlet
+                                                                                                                                                                                                                                                         (RTH, RTR)
+                                                                             EA                                                                                                                                                                          15 7/8" X 21 3/4"
+                                                                                                                                                                                                                                                         Duct Receiving
+                                                                                                                                                                                                                                                         Flange
+                                                                                                                                                        RA                    RARTH, RTF                                                                                                                                                      EA
+                                                                                                                                                                  FA                  ONLY
+                                                                                                                                                                                                                FA                                                                                                                    Power/Control
+                                                                                                 22"                                                    FARTH, RTR                                                                                                                                                                    Wiring Entries
+                                                                                                                                                                                                                                                       10 1/4"ONLY
+                                                                                                                                                                                                                                                                                                                                         7/8 Typ.
+                                                                                                                                                                                                                                                                                                 RA
+                                                                                                                 9 3/8"                                                                                                 RA              FA
+                                                                                                                                                                                                                                                                                     81 5/8" Overall
+                                                                                                                                                                                                                                                                                           79 5/8" CaseRTV, RTRRTV, RTF
+                                                                                                                                                                                                                        ONLY            ONLY
+
+                                                                                                          LEFT VIEW                                     HE6XRT, HE8XRT            HE6XRT, HE8XRT                       FROHE6NXRTT, HVE8XIERTW           HE6XRT, HE8XRT                                  RIGHT VIEW
+
+                                                                       MDAAroavIaRdiwlaFebiLlnel:OgaHsWsTEhy6oCwpXOneR: N:TFUIGniUt RDAimTIOenNsion OA  RTV             BACK      RTF             BACK                            RTH  BACK                      RTR     BACK                                   UNIT MOUNTING & APPLICATION
+                                                                                                                                                                         EA                                            OA               EA            OA                  EA                                    Must be mounted as shown. Airstreams can not
+                                                                                                                                                                              OA                  EA                                                                                                            be switched.
+                                                                                                                                                                                                                       RA               FA                                FA
+                                                                       Version: AUG18                                                                                         RA                                                       FRONT                             FRONT
+
+                                                                                                                                                                                                                                                      HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 8XIN                                                              Energy Recovery Ventilator                                                         For safety listed products,
+                                                                     Standarrdd & Bypass Economizer Option                                                see LE-SERIES models.
+INDOOR UNIT
+                                                                     SPECIFICATIONS
+Download specification at:
+renewaire.com/specifications                                         Ventilation Type:                                                        Options:
+                                                                     Static plate, heat and humidity transfer                                 Onboard variable frequency drives (VFDs) -
+
+                                                                     Typical Airflow Range: 2,000-7,950 CFM                                       one or both airstreams
+                                                                                                                                              Shaft grounding ring on motors with VFDs
+                                                                     AHRI 1060 Certified Core:                                                 Fused disconnect
+                                                                     Eight L125-G5                                                            Integrated programmable controls -
+
+                                                                     Standard Features:                                                          enhanced, premium
+                                                                     TEFC Premium efficiency motors                                            Bypass economizer damper
+                                                                     Motor starters
+                                                                     Non-fused disconnect                                                        (see bypass DIM drawing) -
+                                                                     24 VAC transformer/relay package                                            dry-bulb temperature controls (standard),
+                                                                     Cross-core differential pressure ports                                      enthalpy controls (option)
+                                                                                                                                              Class 1 low leakage motorized isolation dampers -
+                                                                     Filters:                                                                    OA, EA or both airstreams
+                                                                     Total qty. 16, MERV 8: 20" x 20" x 2"                                    Qty. 2, Factory mounted filter alarms -
+                                                                                                                                                 both airstreams
+                                                                     Unit Dimensions & Weight:                                                Double wall construction
+                                                                     88" L x 113 1/2" W x 81 3/4" H                                           Exterior paint - white, custom colors
+                                                                     2,261-3,278 lbs., varies by option(s)
+                                                                                                                                              Accessories:
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                           Filters - MERV 13, 2" (shipped loose)
+                                                                     116" L x 90" W x 90" H                                                   Digital time clock - wall mount (TC7D-W),
+                                                                     3,618 lbs.
+                                                                                                                                                 in exterior enclosure (TC7D-E)
+                                                                     Motor(s):                                                                Carbon dioxide sensor/control -
+                                                                     Qty. 2, Belt drive blower/standard motor packages
+                                                                                                                                                 wall mount (CO2-W), duct mount (CO2-D)
+                                                                        with adjustable sheaves (see table below)                             IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                 duct mount (IAQ-D)
+                                                                                                                                              Motion occupancy sensor/control -
+
+                                                                                                                                                 ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                              Smoke Detector - duct mount (SD-D)
+                                                                                                                                              Electric duct heater - EK series (1–175 kW)
+                                                                                                                                              Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                 (50-400 MBH), installed downstream of any fans
+
+AIRFLOW PERFORMANCE
+
+                   Sheave                                                                   External Static Pressure (in. w.g.)
+                     Adj.
+Motor HP  Blower    Turns       0.00                    0.25         0.50                   0.75       1.00                            1.25       1.50  1.75                          2.00
+           RPM      Open   CFM BHP                                                                                                                                               CFM BHP
+                           5575 3.2                                                                                                                                              3625 2.7
+                     4.5   6200 4.3                     CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP                                                   CFM BHP CFM BHP                4625 3.9
+                      2    6650 5.2                                                                                                                                              5250 4.9
+          1460        0    6000 3.9                     5425 3.2 Th5e2r0m0 al P3e.2rform50a0n0ce R3a.t2ings4G775520135..12.xls4x550 3.0           4270 2.9 8 C4o0r0e0s (IO2M.8)  4300 3.5
+                     4.5   6700 5.3                     6010 4.3 5875 4.2 5700 4.2 5500 4.2 5325 4.1                                              5125 4.1 4900 4.0              5325 5.1
+5.0       1610        2    7225 7.6                                                                                                                                              6000 7.3
+                      0    7000 6.1                                                                                                                                              5875 5.8
+          1725       4.5   7850 8.3                     6500 5.2 6375 5.2 6200 5.2 6050 5.1 5875 5.1                                              5700 5.1 5490 5.0              6775 8.0
+                      2                                                                                                                                                          7150 8.9
+          1560        1                                 5850 3.9 5650 3.8 5475 3.8 5275 3.8 5100 3.7                                              4875 3.7 4600 3.6
+
+7.5       1740                                          6575 5.3 6400 5.3 6300 5.3 6125 5.3 5950 5.2                                              5750 5.2 5575 5.1
+
+          1865                                          7075 7.6 6950 7.6 6800 7.5 6675 7.5 6500 7.5                                              6375 7.4 6200 7.4
+
+          1810                                          6875 6.1 6750 6.1 6600 6.0 6425 6.0 6275 6.0                                              6100 5.9 5925 5.8
+
+10.0      2020                                          7745 8.3 7625 8.2 7450 8.2 7350 8.2 7200 8.1                                              7050 8.1 6925 8.0
+
+          2105                                                       7950 9.1 7800 9.1 7725 9.1 7600 9.0                                          7450 9.0 7300 8.9
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.                    Operation in this zone will likely exceed FLA limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                     CORE PERFORMANCE
+
+          Standard Electrical Specifications                           Optional Factory Installed                                                  Airflow (CFM)
+                                                                     VFD Electrical Specifications
+
+                              FLA                     Max.              FLA                 Min. Cir.      Max.                             2000  4000  6000                     8000
+                           per motor  Min. Cir. Overcurrent          per motor               Amps      Overcurrent                     90%
+HP Volts HZ        Phase               Amps Protection                                                 Protection   Effectiveness (%)
+                           14.5-13.4
+       208-230 60  Three      6.7                    Device                                               Device
+5.0 460 60         Three      5.3
+                   Three              32.6                    45     14.5-13.4 35.9                    45                              70%
+          575 60           21.0-19.0
+                   Three      9.5     15.1                    20                       6.7  16.6       20
+       208-230 60  Three      7.6
+7.5 460 60         Three              11.9                    15                       5.3  13.1       15                              50%
+                           27.0-25.0
+          575 60   Three      12.5    47.3                    60     21.0-19.0 52.0                    60
+                   Three      9.76
+       208-230 60  Three              21.4                    25                       9.5  23.5       25                              30%
+10.0 460 60                                                                                                                                  At AHRI 1060 standard conditions.
+                                      17.1                    20                       7.6  18.8       20                                    See all AHRI certified ratings at www.ahrinet.org.
+          575 60
+                                      60.8                    80     27.0-25.0 66.8                    80
+
+                                      28.1                    35     12.5                   30.9       35
+
+                                      22.0                    30     9.76                   24.2       30
+
+Specifications may be subject to change without notice.
+
+114 RENEWAIRE.COM 1.800.627.4499
+HE8XIN Energy Recovery Ventilator Standard
+
+                                                                                                           OA34 3/4"                                                                                  ABBREVIATIONS
+                                                                                            RA   Minimum                                                                                              EA: Exhaust Air to outside
+                                                                                               Service Area                                                                                           OA: Outside Air intake
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 115                                                                                                                                 RA: Room Air to be exhausted
+                                                                                               34 3/4"  Minimum     Area      Door                                                                    FA: Fresh Air to inside
+                                                                                                           Service            Swing                                                                   INSTALLATION ORIENTATION
+                                                                                                                                                                                                      Unit must be installed in orientation
+                                                                                                                              FA                        EA                E-Box                       shown.
+                                                                                                                                                                          Minimum                     NOTE
+                                                                                                        62"                                                               Service Area                1.ALL UNITS HAVE INTERNAL EA
+                                                                                                                                                                                                      BACKDRAFT DAMPER.
+                                                                                                                                                                 69 1/4"                              UNLESS AN EA MOTORIZED ISOLATION
+                                                                                                                                                                                                      DAMPER IS SPECIFIED.
+                                                                                                                                                                                                      2.UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                      DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                      NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                      3.SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                      TO CHANGE WITHOUT NOTICE.
+
+                                                                                               39 1/4"                               Door   Door
+                                                                                                  Minimum                            Swing  Swing
+                                                                                                      Service
+
+                                                                                                         Area
+
+Pressure  FA Blower Outlet is 16" X 22" (Nom.)                                                                                             85 5/8"      36"                                                       24" X 36"
+Ports        24"X36" Duct Receiving Flange is                                                                                            Minimum                                                                  Duct Receiving
+(4) Typ.      also supplied. Field install only in                                                                                     Service Area               Power and Control Wiring                        Flange Typ.
+                                     location shown.                                                                                                              Entries 7/8" Dia.
+                         113" Overall                                                                                                TOP VIEW                                                                       85 5/8" Case
+                        112 1/2" Case                                                                                                                                  INDOOR UNITS: EA BLOWER Outlet is
+                                                                                                                                      86 1/2" Overall               16" X 22" (Nom.) 24"X36" Duct Receiving
+                                                                                                                                     75 7/8" Lift Lugs            Flange is also supplied. Field install only in
+
+                                                                                                                                                                                     location shown.
+
+   Core                                                                                                 78 1/4" Case
+Access                                                                                                       81 5/8" Overall
+
+   Door
+
+                                                                                                                                                        53 1/2"
+
+2 1/4"    63 1/4"                                                                                10 1/4"                                        81"                                          63 1/4"                         8 3/4"22" Typ.
+                                                                                               76 1/2"                                                                             108"                                  49 5/8"
+                                                                                                                                     FRONT VIEW                           Internal EA Motorized
+                    LEFT VIEW                                                                                                                                             Damper Location (Optional)                   Internal OA Damper
+MDAArovaIaRdiwlaFebiLlnel:OagHsWsTEhyo8CwpXOneIiNNn:dFUimIGneniUtsiRoDnAidmTraIwOeinnNgs. ion                                                                                                                          Location (Optional)
+Version: AUG18                                                                                                                                                            RIGHT VIEW
+                                                                                                                                                                                                                       BACK VIEW
+
+                                                                                                                                                                                                                  UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                                                  Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                                                  be switched.
+
+                                                                                                                                                                 HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 8XIN                                                              Energy Recovery Ventilator                                                         For safety listed products,
+                                                                     Standard with Bypass Economizer                                                      see LE-SERIES models.
+INDOOR UNIT
+                                                                     SPECIFICATIONS
+Download specification at:
+renewaire.com/specifications                                         Ventilation Type:                                                        Options:
+                                                                     Static plate, heat and humidity transfer                                 Onboard variable frequency drives (VFDs) -
+
+                                                                     Typical Airflow Range: 2,000-7,950 CFM                                       one or both airstreams
+                                                                                                                                              Shaft grounding ring on motors with VFDs
+                                                                     AHRI 1060 Certified Core:                                                 Fused disconnect
+                                                                     Eight L125-G5                                                            Integrated programmable controls -
+
+                                                                     Standard Features:                                                          enhanced, premium
+                                                                     TEFC Premium efficiency motors                                            Bypass economizer damper
+                                                                     Motor starters
+                                                                     Non-fused disconnect                                                        (see bypass DIM drawing) -
+                                                                     24 VAC transformer/relay package                                            dry-bulb temperature controls (standard),
+                                                                     Cross-core differential pressure ports                                      enthalpy controls (option)
+                                                                                                                                              Class 1 low leakage motorized isolation dampers -
+                                                                     Filters:                                                                    OA, EA or both airstreams
+                                                                     Total qty. 16, MERV 8: 20" x 20" x 2"                                    Qty. 2, Factory mounted filter alarms -
+                                                                                                                                                 both airstreams
+                                                                     Unit Dimensions & Weight:                                                Double wall construction
+                                                                     88" L x 113 1/2" W x 81 3/4" H                                           Exterior paint - white, custom colors
+                                                                     2,261-3,278 lbs., varies by option(s)
+                                                                                                                                              Accessories:
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                           Filters - MERV 13, 2" (shipped loose)
+                                                                     116" L x 90" W x 90" H                                                   Digital time clock - wall mount (TC7D-W),
+                                                                     3,618 lbs.
+                                                                                                                                                 in exterior enclosure (TC7D-E)
+                                                                     Motor(s):                                                                Carbon dioxide sensor/control -
+                                                                     Qty. 2, Belt drive blower/standard motor packages
+                                                                                                                                                 wall mount (CO2-W), duct mount (CO2-D)
+                                                                        with adjustable sheaves (see table below)                             IAQ sensor - wall mount (IAQ-W),
+
+                                                                                                                                                 duct mount (IAQ-D)
+                                                                                                                                              Motion occupancy sensor/control -
+
+                                                                                                                                                 ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                              Smoke Detector - duct mount (SD-D)
+                                                                                                                                              Electric duct heater - EK series (1–175 kW)
+                                                                                                                                              Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                 (50-400 MBH), installed downstream of any fans
+
+AIRFLOW PERFORMANCE
+
+                   Sheave                                                                   External Static Pressure (in. w.g.)
+                     Adj.
+Motor HP  Blower    Turns       0.00                    0.25         0.50                   0.75       1.00                            1.25       1.50  1.75                          2.00
+           RPM      Open   CFM BHP                                                                                                                                               CFM BHP
+                           5575 3.2                                                                                                                                              3625 2.7
+                     4.5   6200 4.3                     CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP                                                   CFM BHP CFM BHP                4625 3.9
+                      2    6650 5.2                                                                                                                                              5250 4.9
+          1460        0    6000 3.9                     5425 3.2 Th5e2r0m0 al P3e.2rform50a0n0ce R3a.t2ings4G775520135..12.xls4x550 3.0           4270 2.9 8 C4o0r0e0s (IO2M.8)  4300 3.5
+                     4.5   6700 5.3                     6010 4.3 5875 4.2 5700 4.2 5500 4.2 5325 4.1                                              5125 4.1 4900 4.0              5325 5.1
+5.0       1610        2    7225 7.6                                                                                                                                              6000 7.3
+                      0    7000 6.1                                                                                                                                              5875 5.8
+          1725       4.5   7850 8.3                     6500 5.2 6375 5.2 6200 5.2 6050 5.1 5875 5.1                                              5700 5.1 5490 5.0              6775 8.0
+                      2                                                                                                                                                          7150 8.9
+          1560        1                                 5850 3.9 5650 3.8 5475 3.8 5275 3.8 5100 3.7                                              4875 3.7 4600 3.6
+
+7.5       1740                                          6575 5.3 6400 5.3 6300 5.3 6125 5.3 5950 5.2                                              5750 5.2 5575 5.1
+
+          1865                                          7075 7.6 6950 7.6 6800 7.5 6675 7.5 6500 7.5                                              6375 7.4 6200 7.4
+
+          1810                                          6875 6.1 6750 6.1 6600 6.0 6425 6.0 6275 6.0                                              6100 5.9 5925 5.8
+
+10.0      2020                                          7745 8.3 7625 8.2 7450 8.2 7350 8.2 7200 8.1                                              7050 8.1 6925 8.0
+
+          2105                                                       7950 9.1 7800 9.1 7725 9.1 7600 9.0                                          7450 9.0 7300 8.9
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.                    Operation in this zone will likely exceed FLA limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                     CORE PERFORMANCE
+
+          Standard Electrical Specifications                           Optional Factory Installed                                                  Airflow (CFM)
+                                                                     VFD Electrical Specifications
+
+                              FLA                     Max.              FLA                 Min. Cir.      Max.                             2000  4000  6000                     8000
+                           per motor  Min. Cir. Overcurrent          per motor               Amps      Overcurrent                     90%
+HP Volts HZ        Phase               Amps Protection                                                 Protection   Effectiveness (%)
+                           14.5-13.4
+       208-230 60  Three      6.7                    Device                                               Device
+5.0 460 60         Three      5.3
+                   Three              32.6                    45     14.5-13.4 35.9                    45                              70%
+          575 60           21.0-19.0
+                   Three      9.5     15.1                    20                       6.7  16.6       20
+       208-230 60  Three      7.6
+7.5 460 60         Three              11.9                    15                       5.3  13.1       15                              50%
+                           27.0-25.0
+          575 60   Three      12.5    47.3                    60     21.0-19.0 52.0                    60
+                   Three      9.76
+       208-230 60  Three              21.4                    25                       9.5  23.5       25                              30%
+10.0 460 60                                                                                                                                  At AHRI 1060 standard conditions.
+                                      17.1                    20                       7.6  18.8       20                                    See all AHRI certified ratings at www.ahrinet.org.
+          575 60
+                                      60.8                    80     27.0-25.0 66.8                    80
+
+                                      28.1                    35     12.5                   30.9       35
+
+                                      22.0                    30     9.76                   24.2       30
+
+Specifications may be subject to change without notice.
+
+116 RENEWAIRE.COM 1.800.627.4499
+HE8XIN Energy Recovery Ventilator Standard with Bypass Economizer
+
+                                                                                                                                                                                      ABBREVIATIONS
+                                                                                                                                                                                      EA: Exhaust Air to outside
+                                                                                                                                                                                      OA: Outside Air intake
+                                                                                                                                                                                      RA: Room Air to be exhausted
+                                                                                                                                                                                      FA: Fresh Air to inside
+                                                                                                                                                                                      BP: Bypass Air Intake
+                                                                                                                                                         BP34 3/4"
+                                                                        Minimum                                                                                                       INSTALLATION ORIENTATION
+                                                                                                                  OAService Area                                                      Unit must be installed in orientation shown.
+                                                                                                     RA
+                 16" X 38" Bypass Duct Connection                  34 3/4"  Minimum     Area                             16" X 38" Bypass                                             NOTE
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 117(Direct Mount to Damper, By Others)Service       Damper Location                                                 1.ALL UNITS HAVE INTERNAL EA BACKDRAFT DAMPER.
+                                                                                                                                                                                      UNLESS AN EA MOTORIZED ISOLATION DAMPER IS
+Bypass           BP                                                                                  Door                         Optional                   112 5/8" Case            SPECIFIED.
+                                                                                                     Swing                                                          116 3/4" Overall  2.UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE
+                                                                                                                                            5 1/8"                                    ROUNDED TO THE NEAREST EIGHTH OF AN INCH.
+Damper                                                                                                                                                                                3.SPECIFICATIONS MAY BE SUBJECT TO CHANGE
+                                                                                                                                            EA                                        WITHOUT NOTICE.
+                                                                                                     FA
+
+EA                                                             RA              62"
+
+                                                Face Damper                                                                                                                           4. DAMPER SWINGS IN DIRECTION OF AIRFLOW. MIN.
+                                                                                                                                                                                      DUCT CLEARANCE FROM DAMPER BLADE WHEN
+BYPASS AIRFLOW SCHEMATIC                                                                                                                                                              FULLY OPENED TO BE 2". SMACNA RULES APPLY.
+
+                 RIGHT VIEW                                        39 1/4"                               32 3/8"      Door        Door              69 1/4"                           5. UNITS WITH BYPASS WILL REQUIRE ADDITIONAL
+   (OA/FA Airstream Not Shown)                                        Minimum                                         Swing       Swing                                               SPACE FOR THE CONNECTION OF THE BYPASS DUCT
+                                                                          Service                                                                                                     (BY OTHERS).
+               FA Blower Outlet is 16" X 22" (Nom.)
+            24" X 36" Duct Flange is also supplied.                          Area
+
+                 Field install only in location shown.                                                                                                                                6. FOR INSTALLATION DETAILS, REFER TO I&O
+                            102 7/8" Lifting Lugs                                                                                                                                     MANUAL SUPPLEMENT FOR BYPASS.
+                                                                                                                              85 5/8"                        E-Box
+                                                                                                                            Minimum                          Minimum
+                                                                                                                         Service Area       36"              Service Area
+
+                                                                                                                       TOP VIEW                                                               26" X 38" RA Face
+
+                                                                                                         6 3/8" Typ.   86 5/8" Overall      Power and Control Wiring                          Damper Location
+                                                                                                                          85 5/8" Case      Entries 7/8" Dia.                                             Optional
+
+5" Typ.                                                                                                               75 7/8" Lifting Lugs          INDOOR UNITS: EA BLOWER Outlet is                                OA Duct
+                                                                                                                                                    16" X 22" (Nom.) 24"X36" Duct Flange                             Flange
+                                                                                                                                                    is also supplied. Field install only in                          24" X 36"
+                                                                                                                                                    location shown.
+
+                                                                                                                                                                                          2"
+
+           Core                                                                78 1/4" Case                                                 53 1/2"
+        Access                                                                      83 3/8" Overall                                                                                                          22"
+
+           Door                                                                                                                                                                                                                                         21 1/8"
+
+Pressure Ports
+(4) Typ.
+
+        6 3/8"
+         Typ.
+
+                 63 1/4"                                                                                                     81"                                               63 1/4"                    8 3/4"
+                                                                                                                                                                                                      48 3/4"
+         2 1/4"                                                    4"                                                                                                 108"                        Internal OA Damper
+                                                                      10 1/2"                                                                                Internal EA Motorized                Location (Optional)
+                                                                                                                                                             Damper Location (Optional)
+                            LEFT VIEW                                                                                 FRONT VIEW                                                                    BACK VIEW
+MAoIRdFeLl:OHWE8CXIONN[BFyIGpUaRssA]TION                                                                                                                     RIGHT VIEW
+DAravawilabinlegasTsyhpowen:inUdnimitenDsiiomn deranwsiinog.n                                                                                                                                 UNIT MOUNTING & APPLICATION
+Version: AUG18                                                                                                                                                                                Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                              be switched.
+
+                                                                                                                                            HE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HE 8XRT                                                              Energy Recovery Ventilator                                                                               For safety listed products,
+                                                                     Standard                                                                                                    see LE-SERIES models.
+ROOFTOP UNIT
+                                                                     SPECIFICATIONS                                                     Options:
+Download specification at:                                                                                                              Onboard variable frequency drives (VFDs) -
+renewaire.com/specifications                                         Ventilation Type:
+                                                                     Static plate, heat and humidity transfer                              one or both airstreams
+AIRFLOW PERFORMANCE                                                                                                                     Shaft grounding ring on motors with VFDs
+                                                                     Typical Airflow Range: 2,000-7,950 CFM                              Fused disconnect
+                                                                                                                                        Integrated programmable controls -
+                                                                     AHRI 1060 Certified Core:
+                                                                     Eight L125-G5                                                         enhanced, premium
+                                                                                                                                        Class 1 low leakage motorized isolation dampers -
+                                                                     Standard Features:
+                                                                     TEFC Premium efficiency motors                                         OA, EA or both airstreams
+                                                                     Motor starters                                                     Qty. 2, Factory mounted filter alarms -
+                                                                     Non-fused disconnect
+                                                                     24 VAC transformer/relay package                                      both airstreams
+                                                                     Cross-core differential pressure ports                             Double wall construction
+                                                                                                                                        Exterior paint - white, custom colors
+                                                                     Filters:
+                                                                     Total qty. 16, MERV 8: 20" x 20" x 2"                              Accessories:
+                                                                                                                                        Filters - MERV 13, 2" (shipped loose)
+                                                                     Unit Dimensions & Weight:                                          Roof curb - standard 14"
+                                                                     106 1/2" L x 140 1/2" W x 81 3/4" H                                Curb wind clip
+                                                                     2,399-3,416 lbs., varies by option(s)                              Engineered combo curb for Carrier RTU
+                                                                                                                                        Engineered combo curb for Trane RTU
+                                                                     Max. Shipping Dimensions & Weight (on pallet):                     Digital time clock - wall mount (TC7D-W),
+                                                                     Pallet 1 (unit): 116" L x 90" W x 90" H
+                                                                     Pallet 2 (hoods): 60" L x 42" W x 90" H                               in exterior enclosure (TC7D-E)
+                                                                     3,756 lbs.                                                         Carbon dioxide sensor/control -
+
+                                                                     Motor(s):                                                             wall mount (CO2-W), duct mount (CO2-D)
+                                                                     Qty. 2, Belt drive blower/standard motor packages                  IAQ sensor - wall mount (IAQ-W),
+
+                                                                        with adjustable sheaves (see table below)                          duct mount (IAQ-D)
+                                                                                                                                        Motion occupancy sensor/control -
+
+                                                                                                                                           ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                        Smoke Detector - duct mount (SD-D)
+                                                                                                                                        Electric duct heater - EK series (1–175 kW);
+
+                                                                                                                                           designed for indoor ductwork installation only
+                                                                                                                                        Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                           (50-400 MBH), installed downstream of any fans
+
+                     Sheave                                                            External Static Pressure (in. w.g.)
+                       Adj.
+Motor  Blower         Turns       0.00                  0.25         0.50              0.75       1.00                            1.25       1.50  1.75                          2.00
+ HP     RPM           Open   CFM BHP                                                                                                                                        CFM BHP
+                             5575 3.2                   CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP                                              CFM BHP CFM BHP                3625 2.7
+ 5.0    1460           4.5   6200 4.3                                                                                                                                       4625 3.9
+        1610            2    6650 5.2                   5425 3.2 Th5e2r0m0 al P3e.2rform50a0n0ce R3a.t2ings4G775520135..12.xls4x550 3.0      4270 2.9 8 C4o0r0e0s (IO2M.8)  5250 4.9
+ 7.5    1725            0    6000 3.9                                                                                                                                       4300 3.5
+        1560           4.5   6700 5.3                   6010 4.3 5875 4.2 5700 4.2 5500 4.2 5325 4.1                                         5125 4.1 4900 4.0              5325 5.1
+10.0    1740            2    7225 7.6                                                                                                                                       6000 7.3
+        1865            0    7000 6.1                   6500 5.2 6375 5.2 6200 5.2 6050 5.1 5875 5.1                                         5700 5.1 5490 5.0              5875 5.8
+        1810           4.5   7850 8.3                                                                                                                                       6775 8.0
+        2020            2                               5850 3.9 5650 3.8 5475 3.8 5275 3.8 5100 3.7                                         4875 3.7 4600 3.6              7150 8.9
+        2105            1
+                                                        6575 5.3 6400 5.3 6300 5.3 6125 5.3 5950 5.2                                         5750 5.2 5575 5.1
+
+                                                        7075 7.6 6950 7.6 6800 7.5 6675 7.5 6500 7.5                                         6375 7.4 6200 7.4
+
+                                                        6875 6.1 6750 6.1 6600 6.0 6425 6.0 6275 6.0                                         6100 5.9 5925 5.8
+
+                                                        7745 8.3 7625 8.2 7450 8.2 7350 8.2 7200 8.1                                         7050 8.1 6925 8.0
+
+                                                                     7950 9.1 7800 9.1 7725 9.1 7600 9.0                                     7450 9.0 7300 8.9
+
+Note: Brake Horse Power (BHP) is for one blower motor package only.  Operation in this zone will likely exceed FLA limits.
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                CORE PERFORMANCE
+                    Standard Electrical Specifications
+                                                                      Optional Factory Installed                                             Airflow (CFM)
+                                                                     VFD Electrical Specifications
+
+                                FLA     Min.                Max.        FLA            Min. Cir.      Max.                             2000  4000  6000                     8000
+                             per motor   Cir.           Overcurrent  per motor          Amps      Overcurrent                     90%
+HP Volts         HZ  Phase              Amps            Protection                                Protection   Effectiveness (%)
+
+        208-230                                            Device                                    Device
+5.0 460
+                 60 Three 14.5-13.4 32.6                     45      14.5-13.4 35.9               45                              70%
+          575                                                20
+                 60 Three 6.7           15.1                 15      6.7               16.6       20
+        208-230
+7.5 460          60 Three 5.3           11.9                 60      5.3               13.1       15                              50%
+                                                             25
+          575    60 Three 21.0-19.0 47.3                     20      21.0-19.0 52.0               60
+
+        208-230  60 Three 9.5           21.4                 80      9.5               23.5       25                              30%
+10.0 460                                                     35                                                                         At AHRI 1060 standard conditions.
+                 60 Three 7.6           17.1                 30      7.6               18.8       20                                    See all AHRI certified ratings at www.ahrinet.org.
+          575
+                 60 Three 27.0-25.0 60.8                             27.0-25.0 66.8               80
+                 60 Three 12.5 28.1
+                 60 Three 9.76 22.0                                  12.5              30.9       35
+
+                                                                     9.76              24.2       30
+
+Specifications may be subject to change without notice.
+
+118 RENEWAIRE.COM 1.800.627.4499
+                                                                       HE8XRT Energy Recovery Ventilator Standard
+
+                                                                                                 121 1/4" Minimum          39 1/2"                                                                                                                                            ABBREVIATIONS
+                                                                                                    Service Area                                                                                                                                                              EA: Exhaust Air to outside
+                                                                                                                                                                                                                                                                              OA: Outside Air intake
+                                                                       65 3/4" Minimum                    Door     Door                        FA (RTV, RTF)                                               CURB 8X                                                            RA: Room Air to be exhausted
+                                                                          Service Area                    Swing    Swing                       16" X 22"                                                                                                                      FA: Fresh Air to inside
+                                                                                                                                                                                                            76" O.D.                                                          RTV: Rooftop Vertical RA & FA
+                                                                                                                                         15 3/4"                                                                        36"                                                   RTF: Rooftop Vertical FA Only
+                                                                                                                                           135 3/4" Minimum                                                                                                                   RTR: Rooftop Vertical RA Only
+                                                                                                                                               Service Area                                                                                                                   RTH: Rooftop Horizontal RA & FA
+
+                                                                                        26 1/4"                                                                                   99 1/4" I.D.                                      26"                                       INSTALLATION ORIENTATION
+                                                                                                                                                                                                                                                                              Unit must be installed in orientation
+                                                                                                                                                                                                                                                                              shown.
+
+                                                                                                                                                                                                           FA                                                                 NOTE:
+                                                                                                                                                                                                                                                                              1. UNLESS OTHERWISE SPECIFIED,
+                                                                                        71 1/2"                            Door                                                                                                     31"  103" O.D.                            DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                           Swing                                                                                                                                              NEAREST EIGHTH OF AN INCH.
+
+                                                                                                                                                                                                 A                               A                                            2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                          RA                                                  TO CHANGE WITHOUT NOTICE.
+
+                                                                                                                                                                                                                        36"                                CURB CROSS-SECTION A-A (TYP.)
+                                                                                                                                                                                                           72 1/4" I.D.
+                                                                                                 19 7/8"                             20" Minimum                                                                                    26"                     1 1/2" X 1/4"                  1 7/8"
+                                                                                                                                     Service Area                                                       TOP VIEW                                            Neoprene Gasket
+                                                                                                          54 7/8"
+                                                                                                           60 7/8"         RA (RTV, RTR)                                                         140 1/8" Overall                                           3/4" X 3 1/2"
+                                                                                                                           24" X 34"                                                                   109 1/2" Case                                        Wooden Nailer
+                                                                                                             TOP VIEW                                                                                      102 7/8"
+                                                                                                                                                                                                         Lifting Lugs                                                                  3"  14"
+
+                                                                                                                                                                                                                                                                              SECTION A-A
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 119          OA Damper                         OA Inlet                           Pressure                                                                                   1 1/4"                                Disconnect
+                                                                                    Location                                                        Ports                                                                                   Typ.                                            Switch
+                                                                                                                                                    (4) Typ.                                                                             30 1/2"            81 5/8" Overall
+                                                                                  (Optional)                                                                                                                                             EA Outlet              79 5/8" Case  106" Overall
+                                                                       EA Damper                                           RA Inlet                                                                                                                                           83" Case
+                                                                                                                           (RTH, RTF)                                                                                                    FA Outlet
+                                                                          Location                                         24" X 36"                                                                                                     (RTH, RTR)                                                          EA
+                                                                        (Optional)                                                                                                                                                       15 7/8" X 21 3/4"
+                                                                                                                           Duct Receiving OA                                                                                             Duct Receiving                                                    Power/Control
+                                                                             EA                                                                                                                                                          Flange                                                            Wiring Entries
+                                                                                                                           Flange
+                                                                                                                                                                                                                                                                                                              7/8 Typ.
+                                                                                                                           FARTH, RTR                RARTH, RTF
+                                                                                                                                   ONLY                      ONLY
+
+                                                                                                 22"
+
+                                                                                                                 9 3/8"                                                                           RA        FA
+
+                                                                                                                                                                                                 RTV, RTR  RTV, RTF                 10 1/4"
+                                                                                                                                                                                                  ONLY      ONLY
+
+                                                                                                                               HE6XRT, HE8XRT            HE6XRT, HE8XRT                           HE6XRT, HE8XRT                    HE6XRT, HE8XRT
+
+                                                                                                      LEFT VIEW                                                                                  FRONT VIEW                                                                   RIGHT VIEW
+                                                                            AIRFLOW CONFIGURATION
+                                                                                                                                  RTV          BACK                RTF                     BACK            RTH                                 RTR  BACK                              UNIT MOUNTING & APPLICATION
+                                                                       MoAdvaeilalb:leHaEs 8shXowRnTin dimension drawing.                                                                                                  BACK     OA               EA                               Must be mounted as shown. Airstreams can not
+                                                                       Drawing Type: Unit Dimension                                                                                                                                                                                   be switched.
+                                                                       Version: AUG18                                      OA                  EA    OA                                    EA    OA        EA                                        FA
+                                                                                                                                                                                                                                                    FRONT
+                                                                                                                                                     RA                                          RA        FA
+
+                                                                                                                                                                                                           FRONT
+
+                                                                                                                               RA                                                                                                        RA
+                                                                                                                                         FA
+                                                                                                                                                                                       FA
+
+                                                                                                                                                                                                                                 HE-SERIES
+                                                       T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
+
+120 RENEWAIRE.COM 1.800.627.4499
+                                                                                                         OPTIONS & ACCESSORIES
+
+OPTIONS
+
+See individual submittal pages for availability by model.
+
+EC MOTOR                                      u Easy airflow setup using RenewAire’s
+                                                 standard pressure taps
+u Best energy efficiency                         - cuts commissioning time
+u Two speed, single speed, or variable
+
+   speed operation
+
+ELECTRICAL                                    u Independent blower control (IBC)
+u Disconnect fuses and motor starters            available as an option for HE1X and
+                                                 HE1.5X
+
+VARIABLE FREQUENCY DRIVE
+
+u Factory supplied and mounted variable       u Pre-programmed speeds or variable
+   frequency drives (VFDs)                       speed
+   - one or both airstreams
+                                              u Easy airflow setup using RenewAire’s
+u Provides additional control options            standard pressure ports
+                                                 - cuts commissioning time
+u Separate VFD for each airstream
+                                              u Shaft grounding ring on motors with
+u Display/control in electrical box - can be     VFDs
+   remotely mounted
+
+                                                                                        VFD all voltage     VFD
+                                                                                         except 575V     575V only
+
+MOTORIZED ISOLATION DAMPERS
+
+u Class 1, low leakage                        u Damper(s) are factory mounted and
+                                                 wired (except in HE1XIN - shipped
+u Robust, reliable actuators for highest         loose)
+   dependability
+
+u Automatic operation with spring return in
+   event of power loss
+
+FILTER ALARM                                  u Allows for remote indication of loaded
+                                                 (dirty) filter
+u Factory mounted airflow switches - one
+   for each airstream
+
+EXTERIOR PAINT
+u White and custom colors available
+
+                                                                                                  Specifications may be subject to change without notice.
+                                                           FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 121
+OPTIONS & ACCESSORIES
+
+OPTIONS
+
+Bypass Economizer
+
+AVAILABLE ON ALL HE-SERIES INDOOR UNITS
+
+By utilizing what nature offers, our bypass economizer can “free cool” indoor spaces by using tempered and filtered
+outdoor air when the temperature and/or humidity are within a favorable range. This process M A X I M I Z E S
+O P E R AT I N G E F F I C I E N C I E S and R E D U C E S E N E R G Y use and costs, all
+while indoor air quality is Enhanced—a win-win for occupant health, the environment and the bottom line. Bypass
+can now be specified for all RenewAire HE indoor units as a factory option.
+
+KEY BENEFITS
+
+u Reduce energy use and costs:                                              u Ultimate reliability:
+   Energy efficiency is optimized since the bypass provides airside            Our commitment to innovative design practices, expert
+   economizer capabilities to the building mechanical system.                  workmanship and Quick Response Manufacturing ensures
+                                                                               unmatched reliability.
+u Flexible design:
+   Bypass allows for flexibility in the routing of the bypass duct.         u Fast and easy implementation:
+   Additionally, the dampers are adjustable and AMCA Class I                   The economizer option doesn’t affect the current lead time of the
+   certified for low leakage.                                                  base units, and it doesn’t require any additional certifications.
+
+u Increase installation opportunities:                                      u Meet code requirements:
+   HE indoor units can now be specified and installed on projects              Bypass helps HE indoor units meet economizer requirements per
+   that require ERV bypass.                                                    building codes and other referenced standards.
+
+u 100% bypass of air:
+   Unlike other options on the market, RenewAire offers 100% core
+   bypass of air, resulting in free cooling and further energy reductions.
+
+        Specifications may be subject to change without notice.
+122 RENEWAIRE.COM 1.800.627.4499
+                                                                                                             OPTIONS & ACCESSORIES
+
+OPTIONS
+
+Bypass Economizer
+
+The bypass system consists of the addition of an extra bypass duct, two electrically actuated dampers and a control system. Bypass
+is achieved with the help of two dampers consisting of the face damper (normally closed) and the bypass damper (normally closed),
+factory-installed bypass controls and field-installed ductwork that links the return air to the exhaust air. When conditions are favorable
+for bypass, the face damper closes while the bypass damper opens simultaneously, thereby allowing for 100% of the return air to
+bypass the core. The Bypass Economizer option comes with two factory-supplied dampers and a bypass control system of your choice:
+
+DAMPERS                                                             CONTROLS
+
+                   The face damper is factory-installed on                                 Dry-bulb control:
+                   the return air (RA) duct inlet for all units                            The standard bypass control is temperature-
+                   except HE1X. The bypass damper is also                                  based via a single outdoor-air controller
+                   factory-installed on all units except HE1X                              and sensor.
+                   and HE1.5X.
+
+     Square Damper                                                                         Enthalpy control:
+                                                                                           This optional bypass control is based on
+     Circle Damper                                                                         differential enthalpy and uses a return-air
+FIELD-INSTALLED BYPASS DUCT SIZE RECOMMENDATIONS                                           enthalpy sensor in conjunction with an
+                                                                                           outdoor-air enthalpy controller and a
+                                                                                           dry-bulb temperature controller.
+
+    ERV UNIT                           FACE DAMPER               BYPASS DAMPER                RECOMMENDED BYPASS
+                                                                                                           DUCT SIZE*
+
+   HE1XINH, HE1XINV                     Shipped loose                Shipped loose                               12"
+HE1.5XINH, HE1.5XINV                   Factory installed             Shipped loose                               12"
+                                       Factory installed            Factory installed                        16" x 16"
+  HE2XINH, HE2XINV                     Factory installed            Factory installed                        30" x 16"
+          HE3XINH                                                                                            36" x 14"
+           HE3XINV                     Factory installed            Factory installed                        34" x 16"
+          HE4XINH                      Factory installed            Factory installed                        42" x 14"
+           HE4XINV                                                                                           38" x 16"
+
+    HE6XIN, HE8XIN
+
+* Recommended duct sizes are based on ensuring that the pressure drop in the bypass duct is less than the pressure drop through the core. Equivalent duct sizes at same
+ pressure drop are acceptable.
+
+NOTE: Installation of bypass duct per SMACNA guidelines.
+
+100% ECONOMIZER                                                     PARTIAL ECONOMIZER
+
+     VRF/                              The Bypass Economizer                                  RELIEF DAMPER  When connected to a
+  CHILLED                              option will provide 100%                               OPENS DURING   main building air handler,
+  WATER/                               economizer capabilities                                 ECONOMIZER    the Bypass Economizer
+HOT WATER                                                                                                    option shall offer partial
+                                                                                                OPERATION    bypass of only the ERV
+                                                                                                             total airflow. For 100%
+    BYPASS RA                CEILING   in mechanical systems        MECHANICAL ROOM             CEILING      economizer capability on the
+                                       where the ERV is             8,000 CFM                 ROOM           HVAC system, the air handler
+    1500 CFM 1500  RA DUCT             connected to a fan coil                                               must be equipped with either
+                   NOT SHOWN           unit or supplying fresh air                                           powered relief or barometric
+OA         CFM                         directly into the space.                                              relief economizer capacity
+                                       Examples of such systems                                              (barometric relief shown).
+                                                                        BYPASS
+
+EA  ERV     FA                   1500                               2,000 CFM
+           1500                  CFM
+                       FCU                                          OA                 HC
+                   ROOM     FRESH
+           CFM               AIR                                    EA ERV
+                                                                       2,000 CFM
+MECHANICAL ROOM                                                                        AHU
+                                                                                  10,000 CFM
+
+                                       are VRF, Chilled Beam or
+
+                                       Chilled/Heated Panels.
+
+100% BYPASS ECONOMIZER APPLICATION WITH ERV                         PARTIAL ECONOMIZER APPLICATION
+                                                                          WITH BYPASS-EQUIPPED ERV
+
+                                                                                                               Specifications may be subject to change without notice.
+                                                                        FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 123
+OPTIONS & ACCESSORIES
+
+OPTIONS
+
+Integrated Programmable Controls
+
+AVAILABLE ON ALL EV450, HE, LE, RD AND DN-SERIES UNITS
+
+RenewAire’s I N T E G R AT E D P R O G R A M M A B L E
+C O N T R O L S optimize the usability and performance of our
+commercial ERVs by improving functionality, enabling intelligent
+controls, streamlining operations and boosting efficiencies. This is
+accomplished via sophisticated factory-installed microprocessor
+controls and sensors that provide stand-alone ERVs with Direct Digital
+Control (DDC) and/or Building Management System (BMS) control
+interface.
+
+KEY BENEFITS
+
+Optimize usability:                                                    Increase capabilities:
+u Maximize ERV functionality and intelligent control via remote        u Expand ERV connectivity via access to a wide range of open
+
+   Ethernet accessibility and BMS connectivity without third-party        standard protocols, including BACnet and Modbus.
+   interface.
+                                                                       u Broaden ERV interoperability by connecting to third-party
+u Streamline operations by easily managing and changing ERV               equipment and receiving third-party signals for unit control.
+   control parameters via an advanced user interface.
+                                                                       u Expand ERV-application scope by meeting new code
+u Increase uptime reliability through constant system monitoring.         requirements and the needs of institutional customers
+                                                                          requiring DDC controls in mechanical equipment.
+u Achieve cleaner and healthier indoor air via IAQ-based ERV control.
+
+Improve performance:                                                   Simplify operations:
+u Support effective and efficient ERV performance with real-time       u Achieve easier ERV setup, commissioning and balancing via
+
+   data trending and logging capabilities.                               simple-to-install controls.
+
+u Enhance ERV control via access to real-time airflow rates,           u Improve operational efficiencies by easily communicating ERV
+   airstream temperature and airstream humidity.                          status, airflows, temperatures and humidity.
+
+u Facilitate fast and easy ERV upkeep and maintenance with             u Allow for more flexible installations by enabling ERVs to be
+   real-time fan, filter and bypass status.                              interconnected with a BMS, operated independently or run in
+                                                                         concert with other ERVs.
+
+A C C E S S O R I E S AVAILABLE WITH INTEGRATED PROGRAMMABLE CONTROLS
+
+ CO2 sensor (wall or duct mount)*                                      STANDARD       ENHANCED        PREMIUM
+ IAQ sensor (wall or duct mount)*                                      CONTROLS       CONTROLS       CONTROLS
+ Occupancy sensor (ceiling or wall mount)
+ Smoke detector (duct mount)                                                       u              u              u
+ BACnet factory activation (MS/TP or TCP/IP)                                       u              u              u
+ Remote display (handheld or wall mount)                                           u              u              u
+ Room Pressure Sensor (with or without display)                                    u                             u
+ Duct Static Pressure Sensor (with or without display)                                                           u
+ Temperature Sensor Kit (wall or duct mount)**                                                                   u
+                                                                                                                 u
+NOTES                                                                                                            u
+                                                                                                                 u
+*Sensor output is 0-10 vdc, for use as on/off or modulating control.
+**Temperature Sensor Kit is for use with non-integrated heating.
+
+Specifications may be subject to change without notice.
+
+124 RENEWAIRE.COM 1.800.627.4499
+                                                                                                                 OPTIONS & ACCESSORIES
+
+OPTIONS
+
+Integrated Programmable Controls
+
+MODELS                                               FEATURE COMPARISON
+
+STANDARD CONTROLS                                                                                                STANDARD
+                                                                                                                    CONTROLS
+via dry contact and relays                                                                                                 ENHANCED
+Our ERV units are provided with a dry contact                                                                                 CONTROLS
+that can be used to control the unit with a variety                                                                                  PREMIUM
+of low-voltage (24VAC) control devices such as                                                                                           CONTROLS
+remote switches or relays. In addition, third-party
+analog output can be used to operate the ERV.        Ability to automatically enable and disable unit            u  u                                    u
+
+ENHANCED CONTROLS                                    Enable the exhaust fan only (See note 1)                    u  u                                    u
+
+Carel [c.pCOMini] with or without BACnet             Filter alarm for both sets of filters (See note 2)           u  u                                    u
+Enhanced controls offer automated control,
+including temperature and humidity control with      Bypass controls† (See note 3)                               u  u                                    u
+data trending via microprocessor controls and
+sensors that enable BMS connectivity.                Control isolation dampers† (See note 4)                     u  u                                    u
+
+PREMIUM CONTROLS                                     Supply fan only modulation for VFD/EC Motor units†          u  u                                    u
+
+Carel [c.pCOMini] with expansion module              (See note 5 and 6)                                          u  u                                    u
+with or without BACnet
+Premium controls include all functionality of        Exhaust fan only modulation for VFD/EC Motor units†         u  u                                    u
+Enhanced-controls capabilities, as well as
+airflow and IAQ monitoring, demand control,           (See note 5 and 6)
+electric or gas heating options, as well as
+RD-Series cooling and heating control.               Internal time clock (See note 7)
+
+                                                     Defrost controls - Canada only                              u  u                                    u
+
+                                                     Smoke detection - sensor required (See note 8)              u  u                                    u
+
+                                                     Demand control ventilation using CO2 - sensor required u                                            u
+
+                                                     Occupancy-based ventilation - sensor required               u                                       u
+
+                                                     IAQ control ventilation using VOC - sensor required         u                                       u
+
+                                                     Microprocessor controller                                      u                                    u
+
+                                                     Provide supply and exhaust air temperatures                    u                                    u
+
+                                                     Provide outside and return air temperature and humidity†       u                                    u
+
+                                                     Fan status on both fans††                                      u                                    u
+
+                                                     Enable the supply fan only†                                 u  u                                    u
+
+                                                     Enable the exhaust fan only†                                u  u                                    u
+
+                                                     Micro USB port                                                 u                                    u
+
+                                                     Fieldbus port                                                  u                                    u
+
+                                                     BACnet MS/TP or BACnet TCP/IP - activation required            u                                    u
+
+                                                     Modbus                                                         u                                    u
+
+                                                     Data trending                                                  u                                    u
+
+                                                     Outside airflow rate                                                                                 u
+
+                                                     Exhaust airflow rate                                                                                 u
+
+                                                     Space pressure control                                                                              u
+
+                                                     Duct pressure control                                                                               u
+
+                                                     Unit supply air temp                                                                                u
+
+                                                     Heating enable                                                                                      u
+
+                                                     Heating modulation - staged or modulating                                                           u
+
+                                                     Cooling modulation* - staged or modulating                                                          u
+
+                                                     *RD-Series units only  †Not available on EV450              ††EF fan status not available on EV450
+
+                                                     NOTES FOR STANDARD CONTROLS ONLY                            5. VFD (option). Factory installed and wired.
+                                                                                                                 6. EC Motor (option) Potentiometer control factory wired.
+                                                      1. Relays and terminal block (option).                     7. Independent time clock (option).
+                                                      2. Differential pressure sensing tube and pressure switch  8. External smoke detector (option), field installed
+
+                                                          with manual trip point adjustment (option), wiring        in series to shut off unit in adverse conditions.
+                                                          to switch and alarm indication provided by others.
+                                                      3. Option on HE-Series (IN) and standard on RD-Series.
+                                                      4. 24V transformer contactors and relays (option).
+
+                                                                                                                 Specifications may be subject to change without notice.
+
+                                                                            FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 125
+OPTIONS & ACCESSORIES
+
+ACCESSORIES
+
+Standard Controls
+
+Standard controls are intended to turn RenewAire commercial energy recovery ventilation systems on and off at appropriate times.
+Specification, installation and set-up is an easy process. RenewAire HE, LE, and RD Series units come standard with a 24 volt
+transformer/relay package for easy interface with all controls.
+
+It is not necessary that RenewAire controls be used to operate RenewAire units. A wide range of controls or building automation
+systems may be used.
+
+*Available with Standard or Integrated Programmable Controls.
+**Only available with Integrated Programmable Controls.
+
+DIGITAL TIME CLOCK*
+
+u Up to 8 on/off cycles per day or 56 per u Battery back-up                                                box
+
+week                                                            u Wall mount or outdoor enclosure options
+
+u 24 VAC power requirement                                      u Wall mount fits any 4" x 4" electrical
+
+                                                                                                            TC7D-W
+                                                                                                           Wall Mount
+
+                                                                                                                           TC7D-E Control In
+                                                                                                                          NEMA 3R Enclosures
+
+CO2 SENSORS*                                                    u Self calibrates during periods of low
+u Adjustable control from 400-2000 PPM                             occupancy
+u Digital display
+u 24 VAC power requirement                                      u Wall mount or add duct mount accessory
+u Computer/BAS interface for information and
+                                                                                                                                         CO2-D
+   control                                                                                                                            Duct Mount
+
+                                                                                                             CO2-W
+                                                                                                           Wall Mount
+
+IAQ SENSORS*                                                    u Selectable 0-5 or 0-10V dc signal
+                                                                u 24 VAC power required
+u Measures TVOC                                                 u Internal menu for easy set-up
+u Direct correlation to CO2 levels
+u 0-2000 ppm CO2 equivalent output                                                                                                       IAQ-D
+                                                                                                                                      Duct Mount
+   signal
+u Digital display on wall mount
+
+                                                                                                             IAQ-W
+                                                                                                           Wall Mount
+
+MOTION OCCUPANCY SENSORS*
+
+u Passive infared sensor                                        u Coverage floor space
+u Adjustable time-off delay to 30 minutes
+u 24 VAC power requirement                                         - Ceiling mount: 1500 sq. ft.
+u Ceiling mount or directable wall mount                           - Wall mount: 2500 sq. ft.
+
+                                                                u Major motion area                            MC-C                      MC-W
+                                                                                                           Ceiling Mount              Wall Mount
+                                                                   - Ceiling mount: 50 ft. diameter
+                                                                   - Wall mount: 68 x 50 ft.
+
+SMOKE DETECTOR*                                                 u For 100-4000 fpm duct air velocity                         SD-D
+                                                                   applications                                           Duct Mount
+u Photoelectric type detector
+u Plug-in sensor                                                u 24 VAC power requirement
+u Round, square or rectangular duct
+                                                                u Interconnect feature for multi-fan
+   mounting options                                                shutdown
+u Easy access test/reset button and LED
+                                                                u Built-in short circuit protection
+   display
+
+        Specifications may be subject to change without notice.
+126 RENEWAIRE.COM 1.800.627.4499
+                                                                                          OPTIONS & ACCESSORIES
+
+ACCESSORIES
+
+Controls Continued
+
+REMOTE DISPLAY**
+
+u Hand held or wall mount
+u LED display
+u Keypad for easy programming
+
+                                                                                 RD-M
+                                                                       Handheld or Wall Mount
+
+PRESSURE SENSORS (ROOM PRESSURE/DUCT STATIC PRESSURE)**
+
+u With or without display
+
+u Differential pressure transmitter
+
+u 4-20 mA or field selectable 0-10 & 0.5V
+   output signal
+
+u Integral barbed tubing connections that
+   fit 1/8" and 3/16" ID tubing
+
+                                                                       RPS-WOD/DPS-WOD    RPS-WD/DPS-WD
+                                                                         Wall/Duct Mount  Wall/Duct Mount
+                                                                         without Display
+                                                                                             with Display
+
+BACNET FACTORY ACTIVATION**                                                               BN-A
+
+u Allows for communication to a BAS via
+   Bacnet NS/TP
+
+u Factory programmed and tested
+
+TEMPERATURE SENSOR KIT**
+u Duct temperature sensors
+u Hermetically sealed 304SS probe
+u Operating range -40F to 210F
+u Easy installation with integral
+
+   mounting plate
+
+Engineered Combo Curbs                                                                                                                TS
+                                                                                                                              Wall/Duct Mount
+Exclusively designed for select Trane (Voyager and Precedent)
+and Carrier (WeatherExpert, WeatherMaster, and Weathermaker)           Available Options (Special Order)
+models, RenewAire’s engineered combo curb makes it easy to             u Seismic and/or wind load applications
+combine standard Air Handling Unit (AHU) rooftop applications          u Pitched roof applications
+with the benefits of RenewAire energy recovery ventilation.            u High vibration applications
+They eliminate the need for transitional ductwork between the          u Custom curb heights
+RTU and the ERV, reducing the time and costs of installation.          u Heavier metal gauges
+Simply install the curb, run the return and supply duct to the         u Aluminum liners
+curb openings, then install the AHU and RenewAire units onto the
+curb. Additionally, the curbs allow the AHU unit to function in its
+standard operation as well as full-flow economizer modes.
+
+Standard Construction
+u Prime G-90, 18-gauge galvanized steel
+u Fully welded and mitered corners (single piece curb lift)
+u Base flange attachments for securing to the building structure
+u 1 ½" 3 lb. density fiberglass insulation
+u Reinforced with cross channel supports on center
+u Conforms to ASTM A653/A653M (standard specification for sheet metal)
+
+                                                                                                              Specifications may be subject to change without notice.
+                                                                       FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 127
+OPTIONS & ACCESSORIES
+
+ACCESSORIES
+
+Hoods and Dampers
+
+FA10-G & FA12-G                                                 u Hood type wall cap
+u 10" or 12" wall cap                                           u 1/4" metal screen
+u Galvanized finish
+
+FA10-P & FA12-P                                                 u Paintable
+u 10" or 12" wall cap                                           u 1/4" metal screen
+u Galvanneal finish
+
+VW12X12                                                         u Flush mount
+u 12" x 12" x 10" round louver                                  u 1/2" metal screen
+u Galvanized finish
+
+BD10 & BD12                                                     u Mechanical “butterfly” design
+u 10", 12" backdraft damper
+u Male/female ends
+
+        Specifications may be subject to change without notice.
+128 RENEWAIRE.COM 1.800.627.4499
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
+
+                                                                      FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 129
+OPTIONS & ACCESSORIES
+
+ACCESSORIES
+
+RH Series Electric Duct Heater
+
+AVA I L A B L E O N S I N G L E / M U LT I - FA M I LY A N D L I G H T C O M M E R C I A L U N I T S ( S O M E E X C E P T I O N S A P P LY )
+
+RenewAire offers the highest-efficiency energy recovery ventilators (ERVs) on the market. However, during winter
+conditions, supply air from the ERV may be less than optimal for space conditions. By adding R E N E W A I R E ’ S
+R O U N D E L E C T R I C D U C T H E AT E R as an option to our single/multi-family and light
+commercial ERVs, RenewAire can now heat supply air during cooler months to enhance indoor comfort, all via one
+package for ERVs and heaters from a single source.
+
+                                                                  RH SERIES
+                                                                RH-W SHOWN
+
+KEY BENEFITS                                                    u Easy installation: A ZERO clearance rating to combustibles
+                                                                   allows designers and contractors to apply RenewAire heaters
+u A single source reduces time and costs: A single                 with less restrictions onsite.
+   information source, a single purchase point and a single
+   approval package for ERVs and heaters reduces design time    u Ultimate reliability: RenewAire heaters come with our two-year
+   and costs, and streamlines logistics for design engineers       warranty and unmatched reliability. Single-source responsibility
+   and contractors.                                                offers contractors and end users peace of mind and a single call
+                                                                   location for technical, start-up and commissioning questions.
+u More flexibility: RenewAire offers design engineers the
+   capacity to specify ERVs with a matching heater to boost     u Highly certified: CSA certified and evaluated to the applicable
+   flexibility and provide heated air to a single space or         ANSI/UL and CSA Standards, for use in the U.S. and Canada.
+   multiple spaces.
+
+        Specifications may be subject to change without notice.
+130 RENEWAIRE.COM 1.800.627.4499
+                                                                                                                                OPTIONS & ACCESSORIES
+
+RH SERIES                                           Electric Duct Heater (1-11.5 kW)
+                                                    Accessory
+
+                                                                                                                                                            LR 30551
+
+ELECTRIC DUCT HEATER               NEW              SPECIFICATIONS
+
+                                                    Heater Type:                                                   Standard Features:
+                                                    Electric Duct Heater                                           Open-coil element
+                                                                                                                   High grade nickel-chrome element wire
+                                                    Typical KW Range:                                              Thermostat - Integral (RH-D),
+                                                    1–11.5 kW (1, 2, 3, 4, 5, 6, 8, 10, 11.5 kW)
+                                                                                                                      Wall mount (RH-W)
+                                                    Voltages & Phase:                                              Modulating heat output (SCR control)
+                                                    Single phase - 120, 208 and 240V                               Vertical or horizontal operation
+                                                                                                                   Automatic limit switch for primary
+                                                    Control Voltage:
+                                                    24 VAC                                                            over-temperature protection
+                                                                                                                   Manual reset limit switch for secondary
+RH-D (Integral Thermostat)
+                                                                                                                      over-temperature protection
+                                                                                                                   Airflow sensor
+                                                                                                                   Standard control transformer - 24 VAC
+                                                                                                                   Corrosion resistant galvanized steel
+                                                                                                                   Round duct collars
+                                                                                                                   High voltage terminal block connections
+                                                                                                                   Grounding lug
+                                                                                                                   Mounting flanges
+
+                                                    Note: Electric duct heater designed for indoor ductwork installation only.
+
+                                                    Duct Collars                  kW                 V    Size     Width (X)    Height (Y)      Depth (Z)
+                                                         6"                                                        11 1/2"          8"          11 1/2"
+                                                         8"                       1, 2            120, 208, 240 A  11 1/2"         10"          13 1/2"
+                                                         8"                                                        11 1/2"         10"          13 1/2"
+                                                         10"                      3, 4, 5            208  B        11 1/2"         10"          13 1/2"
+                                                         10"                                                       11 1/2"         10"          13 1/2"
+                                                         10"                      3, 4, 5, 6         240  B        15 1/2"         12"          15 1/2"
+                                                         12"                                                       15 1/2"         12"          15 1/2"
+                                                                                  3, 4, 5            208  B
+
+                                                                                  3, 4, 5, 6         240  B
+
+     RH-W (Wall Mount Thermostat)                                                 8, 10, 11.5        240  C
+
+Download specification at:                                                        6, 8, 10, 11.5     240  C
+renewaire.com/specifications
+
+                                                    Y                     Z                                                     DIMENSIONS IN INCHES
+                                                                                                                                SIZE X Y Z
+                                                                              XA                  B       C
+                                                                                                                                 A 11.5 8.0 11.5
+                                                                                                                                 B 11.5 10.0 13.5
+                                                                                                                                 C 15.5 12.0 15.5
+
+                                                                                  RH SERIES HEATER CAPACITY
+                                                                              RH SERIES HEATER CAPACITY
+                                                                          13
+Minimum Airflow                     Heater Capacity  HEATER CAPACITY - kW
+      (CFM)                              (kW)                             12
+
+        30                               1.00                             11
+        60                               2.00
+        90                               3.00                             10
+        120                              4.00
+        150                              5.00                             9
+        180                              6.00
+        240                              8.00                             8
+        300                              10.00
+        345                              11.50                            7
+
+                                                                          6                                                     SAFE OPERATING
+                                                                          5
+                                                                                                                                RANGE
+                                                                          4
+
+                                                                          3
+
+                                                                          2
+
+                                                                          1
+
+                                                                          0
+
+                                                                              30 60 90 120 150 180 210 240 270 300 330 360 500 750 1000
+
+                                                                                                          AIRFLOW - CFM
+
+                                                                                                                                     Specifications may be subject to change without notice.
+                                                                                              FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 131
+OPTIONS & ACCESSORIES
+
+ACCESSORIES
+
+EK Series Electric Duct Heater
+
+AVA I L A B L E O N A L L C O M M E R C I A L U N I T S ( S O M E E X C E P T I O N S A P P LY )
+
+RenewAire offers the highest-efficiency energy recovery ventilators (ERVs) on the market. However, during
+winter conditions, supply air from the ERV may be less than optimal for space conditions. By adding
+C O N F I G U R A B L E E L E C T R I C D U C T H E AT E R S as an accessory to our
+commercial ERVs, RenewAire can now heat supply air during cooler months to enhance indoor comfort,
+all via one package for ERVs and heaters from a single source.
+
+                                                                  FLIPPABLE
+                                                                      EK SERIES
+                                                                          SHOWN
+
+KEY BENEFITS
+
+u A single source reduces time and costs: A single information    u Ultimate reliability: RenewAire heaters come with our
+   source, a single purchase point and a single approval package     two-year warranty and unmatched reliability. Single-source
+   for ERVs and heaters reduces design time and costs, and           responsibility offers contractors and end users peace of
+   streamlines logistics for design engineers and contractors.       mind and a single call location for technical, start-up and
+                                                                     commissioning questions.
+u More flexibility: RenewAire offers design engineers the
+   capacity to specify ERVs with a matching heater to boost       u Highly certified: UL Listed (UL1996 Standard) and CSA certified.
+   flexibility and provide heated air to a single space or
+   multiple spaces.
+
+u Easy installation: A ZERO clearance rating to combustibles
+   allows designers and contractors to apply RenewAire heaters
+   with less restrictions onsite.
+
+        Specifications may be subject to change without notice.
+132 RENEWAIRE.COM 1.800.627.4499
+                                                                                                                                                                                        OPTIONS & ACCESSORIES
+
+EK SERIES                                                   Electric Duct Heater (1-175 kW)
+                                                            Accessory
+ELECTRIC DUCT HEATER
+                                                            SPECIFICATIONS
+Download specification at:
+renewaire.com/specifications                                Heater Type:                                                             Voltages & Phase:
+                                                            Electric Duct Heater                                                     Single phase - 120, 208, 240, 277
+                                                                                                                                     Three phase - 208, 240, 480, 600
+                                                            Typical KW Range:
+                                                            1–175 kW                                                                 Control Voltage:
+                                                                                                                                     24 VAC
+                                                            Standard Features:
+                                                            A disconnecting magnetic control contactor per                           Dimensions:
+                                                                                                                                     Minimum - 8" x 8" (W x H)
+                                                               stage or each 48 Amp circuit within a stage                           Maximum - 99" x 99" (W x H)
+                                                            Open-coil element
+                                                            Staged on/off                                                            Options:
+                                                            Control terminal board                                                   Flange mount
+                                                            Grounding lugs                                                           80-20 (Ni/Cr) A Grade element wire with
+                                                            Automatic limit switch for primary over-
+                                                                                                                                        stainless steel terminals
+                                                               temperature protection                                                Recessed control box 1"
+                                                            Manual reset limit switch for secondary over-                            Gasketed cover - dust tight
+                                                                                                                                     Power fusing, standard for heaters drawing more
+                                                               temperature protection
+                                                            Non-adjustable airflow switch                                                than 48 Amps
+                                                            Standard control transformer - 24 VAC                                    2-stage
+                                                            Disconnect switch                                                        Electronic step controller (4-stage)
+                                                            Duct thermostat with sensor for on/off control                           SCR (up to 96 Amps)
+                                                            60-20-20 (Ni/Cr/Fe) C Grade element wire with                            SCR Vernier (over 96 Amps)
+                                                                                                                                     Pilot light
+                                                               nickel-plated terminals
+                                                            Slip-in mount                                                            Accessory:
+                                                            No left/right hand                                                       Room thermostat
+                                                            Vertical up/down flow                                                     Room/duct thermostat-sensor kit for SCR control
+
+                                                            Note: Electric duct heater designed for indoor ductwork installation only.
+
+    EK SEREIKESSeHrieEsAHTeaEteRr CCaApaPcAityCITY                                                                                  PRESSURPEREDSRSOUPRETHDRROOPUGTHHRHOEUAGTHERHEATER
+
+200                                                                                                                           0.18
+
+175HEATER CAPACITY - kW                                                                                                       0.16                                                                            4
+
+150                                                                                   Static Pressure Drop - Inches of Water  0.14
+
+                                                                                                                                                                                                                              3
+
+                                                                                                                              0.12
+
+125                                                                                                                           0.1
+
+100                                                                                                                           0.08                                                                            2
+
+                                                                                                                              0.06
+
+75
+
+                    SAFE OPERATING                                                                                            0.04
+
+50                           RANGE                                                                                                                                                                                            1
+
+                                                                                                                              0.02
+
+25                                                                                                                            0
+                                                                                                                                 0
+                                                                                                                                     200
 400
 600
 800
 1000
 1200
 1400
 1600
 1800
 2000
 2200
+
+0                                                                                                                                    Air Velocity - FPM (1, 2, 3 and 4 - the number of rows of heater coils)
+                                                                                                                                       When the number of rows of heater coils is unknown, assume 4.
+     0  2500  5000  7500     10000                  12500
+
+              AIRFLOW - CFM
+
+        FLIPPABLE
+        CAPABILITIES
+
+        Unique to the EK series, this unit has the ability
+        to flip 180°. Additionally, EK heaters feature
+        both vertical up and vertical down airflow.
+
+                                                                                                                                                                            Specifications may be subject to change without notice.
+                                                                                                                                     FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 133
+                                                       T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
+
+134 RENEWAIRE.COM 1.800.627.4499
+                                                                                                           OPTIONS & ACCESSORIES
+
+ACCESSORIES
+
+Indirect Gas-Fired Duct Furnace
+
+AVA I L A B L E O N A L L C O M M E R C I A L U N I T S ( S O M E E X C E P T I O N S A P P LY )
+
+RenewAire offers some of the highest-efficiency energy recovery ventilators (ERVs) on the market. However,
+during winter conditions, supply air from the ERV may be less than optimal for space conditions. By providing
+an indoor and outdoor I N D I R E C T G A S - F I R E D D U C T F U R N A C E as an accessory
+for our commercial ERVs, in addition to the Electric Duct Heater, RenewAire ERVs now have increased
+flexibility for controlling supply-air temperature during cooler months. This enhances indoor comfort, makes
+ERV installations easier and is possible via a single source for ERVs and furnaces.
+
+                                                                     GH OUTDOOR SERIES
+                                                                                                    SHOWN
+
+KEY BENEFITS
+
+u A single source for your ERV and furnace reduces time and          u Expert guidance: The RenewAire customer-support team will
+   costs: A single information source, a single purchase point and      provide detailed and expert guidance for how best to install the
+   a single approval package for ERVs and heaters reduces design        indoor and outdoor gas-fired duct furnace with an ERV.
+   time and costs, as well as streamlines logistics for design
+   engineers and contractors.                                        u Ultimate reliability: RenewAire furnaces come with our
+                                                                        two-year warranty and unmatched reliability. Single-source
+u Increased capabilities and flexibility: RenewAire offers              responsibility offers contractors and end users peace of
+   design engineers the capacity to specify ERVs with a matching        mind and a single call location for technical, start-up and
+   indoor or outdoor gas-fired furnace to increase ERV capabilities     commissioning questions.
+   and flexibility for providing a single space or multiple spaces
+   with tempered air conditions to equal wintertime loads.           u Highly certified: ETL-listed to the requirements of ANSI Z83.8/
+                                                                        CSA 2.6.
+u More and easier applications: The addition of the indoor
+   and outdoor indirect gas-fired duct furnace as an option
+   ensures that RenewAire ERVs can be easily specified on more
+   applications that require gas heating of the recovered air.
+
+                                                                                                            Specifications may be subject to change without notice.
+                                                                     FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 135
+OPTIONS & ACCESSORIES
+
+GH INDOOR Indirect Gas-Fired Duct Furnace
+                                                                 Accessory
+
+INDOOR                                                                       SPECIFICATIONS                                      Standard Features (continued):
+Indirect Gas-Fired Duct Furnace                                                                                                  Flame rollout switch
+                                                                             Heater Type:                                        Manual shut off valve
+                                              Indoor IN-KI shown             Indirect Gas-Fired Duct Furnace                     3/8" condensate drain connection
+Download specification at:
+renewaire.com/specifications                                                 Typical Input Capacity (MBH):                       Voltages & Phase:
+                                                                             50, 75, 100, 125, 150, 175,                         Single phase - 120V, 208V, 230V
+                                                                             200, 250, 300, 350, 400
+                                                                                                                                 Control Voltage:
+                                                                             Standard Features:                                  24 VAC
+                                                                             Tubular heaters
+                                                                             Indirect natural gas fired                           Dimensions:
+                                                                             Indoor installation                                 See table 2
+                                                                             80% thermal efficiency
+                                                                             Horizontal airflow                                   Shipping:
+                                                                             Rated for elevations from 0 – 2,000 ft.             Shipped loose with base unit and installed in the field
+                                                                             409 stainless steel heat exchanger
+                                                                             409 stainless steel burners                         Options:
+                                                                             Flue/combustion air – indoor models                 Indirect propane fired fuel
+                                                                                                                                 Elevation correction for elevation > 2,000 ft.
+                                                                                Vertical (separated indoor)                      304 stainless steel heat exchanger
+                                                                                Vertical top exhaust with louvered intake        5:1 continuous electronic modulation for all furnaces
+                                                                             Direct spark ignition                               10:1 continuous electronic modulation for furnaces
+                                                                             1-stage/2-stage gas controls
+                                                                             Induced draft venting                                  200 MBH and larger
+                                                                             Terminal block for power and control wiring         Duct thermostat for modulation control
+                                                                             Automatic high limit safety shut-off                Disconnect switch
+                                                                             Auxiliary manual high limit switch                  Power fusing
+                                                                             Combustion air pressure switch
+                                                                             Air proving switch                                  Accessory:
+                                                                             Combination gas valve with shutoff                  Duct thermostat for 1-stage/2-stage control
+                                                                                                                                 Duct thermostat for modulation control
+
+FLUE AND COMBUSTION AIR CONFIGURATION
+
+          IN-KI                            IN-SI                             Note: The total equivalent length of vent pipe must not exceed 50 feet. If equivalent length exceeds 50 feet refer
+     (TOP EXHAUST)            (SEPARATE INLET EXHAUST)                                to IOM for recommendations.
+
+  FLUE                                         FLUE             COMBUSTION   Caution: All indirect gas-fired duct furnaces to be installed downstream of the ERV and on the positive side of the
+EXHAUST                                      EXHAUST               INTAKE                 supply fan.
+
+AIRFLOW              AIRFLOW  AIRFLOW                               AIRFLOW
+
+         COMBUSTION
+            INTAKE
+
+TEMPERATURE RISE AND PRESSURE DROP
+
+    FIGURE 1 GAS FURNACE 50-200 MBH                                                                     FIGURE 2 GAS FURNACE 250-400 MBH
+
+                                      Gas Furnace 50 ‐ 200 MBH                                                                      Gas Furnace 250 ‐ 400 MBH
+
+60                                                                                      0.32        60                                                                                 1.6
+
+55                                                                                            0.28  55                                                                                 1.4
+
+50                                                                                 200              50                                                                                 1.2
+45
+40                                                                                            0.24
+Temperature Rise (deg. F)35                                                                                                                                                       400
+                                                                                                            Pressure Drop (inch‐w.c.)30
+                                                                                                                 Temperature Rise (deg. F)252001750.2045                400       350
+                                                                                                                                                                                                                              Pressure Drop (in.‐w.c.)20175
+                              150                                                       0.16                                                                       350                       1.0
+     0
+                                                                                                    40                                                                            300
+
+                                                                                                                                                             300                             0.8
+
+                                        125                                             0.12        35                     250                                               250       0.6
+                                 100
+                           75                                 150                       0.08        30                                                                                 0.4
+                     50                                        125
+                                                              100
+                                                                                        0.04        25                                                                                 0.2
+                                                      50/75
+
+         1000        2000                    3000     4000          5000     6000            0.00   20      3000  4000     5000  6000 7000 8000                                                                  0.0
+                                                                                        7000          2000                          Airflow (CFM)                            9000 10000 11000 12000
+
+                                             Airflow (CFM)
+
+        Specifications may be subject to change without notice.
+136 RENEWAIRE.COM 1.800.627.4499
+                                                                                                                                                                                                                                                                                                                               OPTIONS & ACCESSORIES
+
+       DUCT FURNACE DIMENSIONS                                                                                                                                                                             FIGURE 4 IN-SI (SEPARATE INLET EXHAUST INDOOR)
+       FIGURE 3 IN-KI (TOP EXHAUST INDOOR)
+                                                                                                                                                                22.92                                                                      FLUE GAS EXHAUST                                                                                                                   22.92
+                     FLUE GAS EXHAUST                                                                                                                            (H)                                                                                                D                                                                                                          (H)
+                                              D
+                                                                                                                                                     14.89                                                                        COMBUSTION AIR INLET                                                                                                     14.89
+       COMBUSTION AIR INLET                                                                                                                                                                                                                                      D
+
+                                                                                                          23.99                                                                                                                                                                                                  23.99
+                                                                                                                                                                                                                                                                                        OUTDOOR TOP EXHAUST (NO)
+                                                                               OUTDOOR TOP EXHAUST (NO)
+                                                                                                      47.85                                                                                                                                                                                               47.85
+                                                                                                        (L)                                                                                                                                                                                                 (L)
+
+                                                                W              UNLESS OTHERWISE SPECIFIED,  RenewAire LLC                                                        4510 Helgesen Dr.                                                                     W                UNLESS OTHERWISE SPECIFIED,       RenewAire LLC                                                               4510 Helgesen Dr.
+                                                                               DIMENSIONS ARE IN INCHES.                                                                     Madison, WI 53718 USA                                                                                      DIMENSIONS ARE IN INCHES.                                                                                  Madison, WI 53718 USA
+       TABLE 2                                                                 TOLERANCES:                                                                                                                                                                                              TOLERANCES:
+                                                                               LINEAR 0.015                                                                                     TEL: (608) 221-4499                                                                                                                                                                                                   TEL: (608) 221-4499
+                        LEVEL DESCRIPTION OF REVISION                          HOLE SIZE 0.005                                                                                  FAX: (608) 221-2824                                                                                                                                                                                                  FAX: (608) 221-2824
+                                                                               ANGULARITY 3                                                                                 TOLL FREE: (800) 627-4499                                                                                                                                                                                              TOLL FREE: (800) 627-4499
+         Size Tubes Input Rate                                                 SURFACE FINISH =                                                                                                                                                                                         LINEAR 0.015
+                                                                                                                                                                                                                                                                                        HOLE SIZE 0.005
+       DESCRIPTION OF REVISION                                                     63 MICROINCH MINIMUM     TITLE: HDG-400-M-N GAS HEATER OUTDOOR                                                                                                                                       ANGULARITY 3                      TITLE: HDG-400-M-N GAS HEATER OUTDOOR
+                                                                                                                                                                                                                                                                                        SURFACE FINISH =
+
+                                                                                                                                                                                                                                                                                            63 MICROINCH MINIMUM
+
+                                                                               MATERIAL:                                                DRAWN BY:        DATE:  DWG. NO.                                                                                                             -  MATERIAL:                                                     DRAWN BY:        DATE:  DWG. NO.
+                                                                         INDOOR TOP EXHAUST (KI) -                                                                                                                                                                                                                        DO NOT SCALE DRAWING.
+                                                                                                            DO NOT SCALE DRAWING.       CAH          10/19/16         SK4750A                                                                                                                                             REMOVE ALL BURRS, BREAK     CAH          10/19/16         SK4750A
+                                                                                                            REMOVE ALL BURRS, BREAK
+                                                                                                            SHARP EDGES.                                                                                                                                                                                                  SHARP EDGES.
+                                                                                                                                                                                                                                                                                                                          APPLICABLE STANDARDS: DIM.
+                                                                                                                                                                                                                                                                                                                          AND TOL. ANSI Y14.5
+                                                                                                            APPLICABLE STANDARDS: DIM.                                                                                                                                    Vent Locations INDOOR SEPARATED COMBUSTION (SI) DATE
+                                                                                                            AND TOL. ANSI Y14.5                                                                                                                                                                   FINISH:
+                                                                                 ReneMwiAni/rMe aLLxCTemperature Rise through Furnace (°F) FINISH:CHECKED BY:DATE:          SIZE A                                                                                                   BY                                                               CHECKED BY:      DATE:              SIZE A SHEET 1 OF 1
+
+                                                                               BY
+                                                                                   UNLESS OTHERWISE SPECIFIED,
+                                                                                   DIMENSIONS ARE IN INCHES.
+                                                                                   TOLERANCES:
+                                                                         DATE                                                           --           --         SCALE:1:16          SHEET 1 OF 1          4510 Helgesen Dr.       LEVEL DESCRIPTION OF REVISION                                                                                       --           --         SCALE:1:16
+                                                                                                                                                                                                       Madison, WI 53718 USA
+                                                                                                                                                                                                                                                                                                                                                                                          Shipping 4510 Helgesen Dr.
+                                                                                                                                                                                                          TEL: (608) 221-4499                                                                                                                                                                                                       Madison, WI 53718 USA
+                                                                                                                                                                                                         FAX: (608) 221-2824                                                                                                                                                                                                           TEL: (608) 221-4499
+                                                                                                                                                                                                       TOLL FREE: (800) 627-4499                                                                                                                                                                                                       FAX: (608) 221-2824
+                                                                               LINEAR 0.015                                                                                                                                                                                          UNLESS OTHERWISE SPECIFIED,          Unit RenewAire LLC                                               Weight TOLL FREE: (800) 627-4499
+                                                                                         HOLE SIZE 0.005
+                                                                                                            TITLE: HDG100-M-KI                                                                                                                                                    IN-KI, IN-SI DIMENSIONS ARE IN INCHES.  Diameter Weight TITLE: HDG100-M-KI
+                                                                   OutputANGULARITY 3                                                                                                                                                                                                               TOLERANCES:
+                                                                                         SURFACE FINISH =                                                                                                                                                                                           LINEAR 0.015
+                                                                           20 63 MICROINCH MINIMUM          25 30 DO NOT SCALE DRAWING.                         35DATE:     40 DWG. NO.                45                         50  55                         60                  HOLE SIZE 0.005
+                                                                                            MATERIAL:                                                                                                                                                                                ANGULARITY 3
+                                                                                                                                                   DRAWN BY:                                                                                                                         SURFACE FINISH =
+
+                                                                                                            REMOVE ALL BURRS, BREAK                                                 SK4700A                                                                            "W"           "L" "H" 63 MICROINCH MINIMUM         "D" DO NOT SCALE DRAWING.
+                                                                                                            SHARP EDGES.
+                                                                                                            APPLICABLE STANDARDS: DIM. CHECKED BY:                                                                                                                                                                                                        DRAWN BY:           DATE:  DWG. NO.
+                                                                                            FINISH:         AND TOL. ANSI Y14.5                                 DATE:                                                                                                                MATERIAL:
+                                                                                                                                                                                                                                                                                                                                                                                           SK4700A
+LEVEL                                                              DATE        BY                                                                                           SCALE:1:24   SIZE A SHEET 4 OF 4                                                                                                              REMOVE ALL BURRS, BREAK
+                                                                                                                                                                                                                                                                                                                          SHARP EDGES.
+                                                                                                                                                                                                                                                                                                                          APPLICABLE STANDARDS: DIM. CHECKED BY:
+                                                                                                                                                                                                                                                                                               FINISH:                    AND TOL. ANSI Y14.5                                 DATE:                   SIZE A
+
+       MBH Qty. Btuh                                                     Btuh                                                                                                                                    LEVEL DESCRIPTION OF REVISION                              DATE  BY                       inch                inch                                    lb                 SCALE:1:24                          SHEET 3 OF 4
+
+                                                                                                                                             Nom. Duct Opening Airflow (CFM)                                                                                            inch        inch                                                                                                       lb
+
+       50 3 50,000 40,000 1852 1481 1235 1058 926 823 741 673 617 15.7                                                                                                                                                                                                                                                                                             127                    207
+
+       75 3 75,000 60,000 2778 2222 1852 1587 1389 1235 1111 1010 926 15.7                                                                                                                                                                                                                                                                                         127                    207
+
+       100 4 100,000 80,000 3704 2963 2469 2116 1852 1646 1481 1347 1235 18.4                                                                                                                                                                                                                                                  5                                   142                    222
+       125 5 125,000 100,000 4630 3704 3086 2646 2315 2058 1852 1684 1543 21.2
+                                                                                                                                                                                                                                                                                                                                                                   169                    249
+
+       150 6 150,000 120,000 5556 4444 3704 3175 2778 2469 2222 2020 1852 23.9                                                                                                                                                                                                                                                                                     160                    240
+
+       175 7 175,000 140,000 6481 5185 4321 3704 3241 2881 2593 2357 2160 26.7 47.8 22.9                                                                                                                                                                                                                                                                           180                    260
+
+       200 8 200,000 160,000 7407 5926 4938 4233 3704 3292 2963 2694 2469 29.4                                                                                                                                                                                                                                                                                     196                    276
+
+       250 10 250,000 200,000 9259 7407 6173 5291 4630 4115 3704 3367 3086 34.9                                                                                                                                                                                                                                                                                    245                    325
+
+       300 12 300,000 240,000 11111 8889 7407 6349 5556 4938 4444 4040 3704 40.4                                                                                                                                                                                                                                               6                                   279                    384
+
+       350 14 350,000 280,000 12963 10370 8642 7407 6481 5761 5185 4714 4321 45.9                                                                                                                                                                                                                                                                                  324                    429
+
+       400 15 400,000 320,000 14815 11852 9877 8466 7407 6584 5926 5387 4938 48.7                                                                                                                                                                                                                                                                                  394                    499
+
+       Note: For a single furnace, 20° F minimum temperature rise, 60° F maximum temperature rise.
+       INDIRECT GAS-FIRED DUCT FURNACE DIMENSIONS
+
+                                                                                                                                                                                                                                                                       NOTES
+                                                                                                                                                                                                                                                                       1. UNLESS OTHERWISE SPECIFIED,
+
+                                                                                                                                                                                                                                                                               DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                                               NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                                       2. SPECIFICATIONS SUBJECT TO
+                                                                                                                                                                                                                                                                               CHANGE WITHOUT NOTICE.
+
+                                                                                                                                                                            TOP VIEW
+
+                                                                                                                                               36"
+                                                                                                                                        Service Area
+
+            14 7/8"                                                                                                                                                                                                                                                                                     47 3/8"
+          Opening                                                                                                                                                                                                                                                                                        Case
+
+       6 1/8"                                                                                                                                                                                                                     View Port      25"                                                                                                                    14 7/8"
+                                                                                                                                                                                                                                                Case                                                                                                                   Opening
+
+                                                                                                                                                                                                                                                                                                                                                                               6 1/8"
+
+                                                                                                            24"                                                                                                                                                           24"
+
+                                                                         3"                                 Opening                                                                                                               3/8" Condensate                      Opening                                            3"
+                                                                         LEFT VIEW
+                                                                                                                          Power Wiring and                                                                                        Drain Tube
+
+                                                                                                                          Control Wiring                                                       3/4" Gas Connection                                                                      RIGHT VIEW
+                                                                                                                          Inlet Fittings                                    FRONT VIEW
+
+                                                                                                                                                                            UNLESS OTHERWISE SPECIFIED,                               RenewAire LLC                                  Specifications                        may  be       subject            to      change without 4510 Helgesen Dr.  notice.
+                                                                                                                                                                            DIMENSIONS ARE IN INCHES.                                                                                                                                                                 Madison, WI 53718 USA
+                                                                                                                                                                            TOLERANCES:                                                                                                                                                                                       TEL: (608) 221-4499
+                                                                                                                                                                            LINEAR 0.015                                                                                                                                                                               FAX: (608) 221-2824
+                                                                                                                                                                            HOLE SIZE 0.005                                                                                                                                                                            TOLL FREE: (800) 627-4499
+                                                                                                                                                                            ANGULARITY 3
+                                                                                                                                                                            SURFACE FINISH =                                      HDG100-M-KI DIM SPEC FOTIRTLET:HE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM                                                                                                 137
+
+                                                                                                                                                                                63 MICROINCH MINIMUM
+
+                                                                                                                                                                                                                                                                          DRAWN BY:                     DATE:             DWG. NO.
+OPTIONS & ACCESSORIES
+
+GH OUTDOOR Indirect Gas-Fired Duct Furnace
+                                                                           Accessory
+
+ROOFTOP                                                                                  SPECIFICATIONS                                     Standard Features (continued):
+Indirect Gas-Fired Duct Furnace                                                                                                             Combination gas valve with shutoff
+                                                                                         Heater Type:                                       Flame rollout switch
+                                          Rooftop RT-NO shown                            Indirect Gas-Fired Duct Furnace                    Manual shut off valve
+Download specification at:                                                                                                                  3/8" condensate drain connection
+renewaire.com/specifications                                                             Typical Input Capacity (MBH):
+                                                                                         50, 75, 100, 125, 150, 175,                        Voltages & Phase:
+                                                                                         200, 250, 300, 350, 400                            Single phase - 120V, 208V, 230V
+
+                                                                                         Standard Features:                                 Control Voltage:
+                                                                                         Tubular heaters                                    24 VAC
+                                                                                         Indirect natural gas fired
+                                                                                         Outdoor installation                               Dimensions:
+                                                                                         80% thermal efficiency                              See table 1
+                                                                                         Horizontal airflow
+                                                                                         Rated for elevations from 0 – 2,000 ft.            Shipping:
+                                                                                         409 stainless steel heat exchanger                 Shipped loose with base unit and installed in the field
+                                                                                         409 stainless steel burners
+                                                                                         Flue/combustion air – outdoor models               Options:
+                                                                                                                                            Indirect propane fired fuel
+                                                                                            Horizontal separated outdoor with hoods         Elevation correction for elevation > 2,000 ft.
+                                                                                            Vertical top exhaust with intake hood           304 stainless steel heat exchanger
+                                                                                         Direct spark ignition                              5:1 continuous electronic modulation for all furnaces
+                                                                                         2-stage gas controls                               10:1 continuous electronic modulation for furnaces
+                                                                                         Induced draft venting
+                                                                                         Terminal block for power and control wiring           200 MBH and larger
+                                                                                         Automatic high limit safety shut-off               Duct thermostat for modulation control
+                                                                                         Auxiliary manual high limit switch                 Disconnect switch
+                                                                                         Combustion air pressure switch                     Power fusing
+                                                                                         Air proving switch
+                                                                                                                                            Accessory:
+                                                                                                                                            Duct thermostat for 2-stage control
+                                                                                                                                            Duct thermostat for modulation control
+                                                                                                                                            Duct curb
+
+FLUE AND COMBUSTION AIR CONFIGURATION
+
+            RT-NO                                                      RT-WO             Caution: All indirect gas-fired duct furnaces to be installed downstream of the ERV and on the positive side of the
+       (TOP EXHAUST)                                              (FRONT EXHAUST)                     supply fan.
+
+                  FLUE
+               EXHAUST
+
+    AIRFLOW                              AIRFLOW         FLUE                   AIRFLOW
+                                                       EXHAUST
+
+                                                       AIRFLOW
+
+             COMBUSTION                                           COMBUSTION
+                INTAKE                                               INTAKE
+
+TEMPERATURE RISE AND PRESSURE DROP
+
+    FIGURE 1 GAS FURNACE 50-200 MBH                                                                                 FIGURE 2 GAS FURNACE 250-400 MBH
+
+                                      Gas Furnace 50 ‐ 200 MBH                                                                                  Gas Furnace 250 ‐ 400 MBH
+
+60                                                                                                  0.32        60                                                                                 1.6
+
+55                                                                                                        0.28  55                                                                                 1.4
+
+50                                                                                             200              50                                                                                 1.2
+
+                                                                                                          0.24
+Temperature Rise (deg. F)                                                                                                                                                                     400
+                                                                                                            Pressure Drop (inch‐w.c.)
+45                                                                                                                Temperature Rise (deg. F)2001750.2045                             400       350
+                                                                                                                                                                                                                              Pressure Drop (in.‐w.c.)
+                                                       175                                                                                                                                               1.0
+
+40                                                150                                               0.16                                                                       350            300
+
+                                                                                                                40                                                                                       0.8
+
+                                                                                                                                                                         300
+
+35                                                125                                               0.12        35                    250                                                250       0.6
+
+                                             100
+
+30                                       75                       150                               0.08        30                                                                                 0.4
+
+                                     50                                    125                      0.04        25                                                                                 0.2
+                                                                          100
+25
+                                                                  50/75
+
+20                                                                                                       0.00   20                                                                                                           0.0
+                                                                                                    7000          2000                                                                   9000 10000 11000 12000
+    0        1000                        2000          3000       4000          5000     6000                           3000  4000    5000  6000 7000 8000
+                                                                                                                                               Airflow (CFM)
+                                             Airflow (CFM)
+Specifications may be subject to change without notice.
+
+138 RENEWAIRE.COM 1.800.627.4499
+DUCT FURNACE DIMENSIONS                                                                                                                                                                                                             OPTIONS & ACCESSORIES
+FIGURE 3 RT-NO (TOP EXHAUST OUTDOOR)
+                                                                                                                                                              FIGURE 4 RT-WO (FRONT EXHAUST OUTDOOR)
+
+               FLUE GAS EXHAUST                                                                                        22.92                           FLUE GAS EXHAUST                                                                                                                  34.92
+                                        D                                                                               (H)                           COMBUSTION AIR INLET                                                                                                                (H)
+
+COMBUSTION AIR INLET                                                                                14.89                                                                                                                                                                       14.89
+
+                                                                                        23.99
+
+                                                                                 47.85                                                                                                                                                                   23.99
+
+                                           W                                     (L)
+
+                                                                                                                                                                                                              W                                  47.85
+
+                                                                                                                                                                                                                                                 (L)
+
+     TABLE 1                                     OUTDOOR TOP EXHAUST (NO)
+
+        Size Tubes                                  UNLESS OTHERWISE SPECIFIED,                                                    4510 Helgesen Dr.                                                                OUTDOOR FRONT EXHAUST (WO)
+                                                                                                                                    Madison, WI 53718 USA
+LEVEL DESCRIPTION OF REVISION                                                                                                          TEL: (608) 221-4499
+                                                                                                                                       FAX: (608) 221-2824
+
+                                                                                                                                   TOLL FREE: (800) 627-4499
+                                                    DIMENSIONS ARE IN INCHES.    RenewAire LLC
+                                                    TOLERANCES:
+                                                    LINEAR 0.015                 MHiDnG/M-4ax00T-eMm-pNerGatAuSreHREiAseTEtRhrOouUgThDFOuOrnRace (°F) TITLE:                                                     Vent Locations UNLESS OTHERWISE SPECIFIED,
+                                                    HOLE SIZE 0.005                                                                                                                                                                                          DIMENSIONS ARE IN INCHES.                                                4510 Helgesen Dr.
+                                                    ANGULARITY 3                                                                                                                                                             RenewAire LLC TOLERANCES:                                                                            Madison, WI 53718 USA
+                                                    SURFACE FINISH =                                                                                                                                                                                         LINEAR 0.015
+                                           Output63 MICROINCH MINIMUM                                                                                                                                                    Unit Shipping HOLE SIZE 0.005                                                                               TEL: (608) 221-4499
+                               Input Rate                                                                                                                                                                                                                                                                                            FAX: (608) 221-2824
+                                                                                                                                                                                                         RT-NO, RT-WO RT-NO RT-WO Diameter ANGULARITY 3                                                                          TOLL FREE: (800) 627-4499
+                                                                                                                                                                                                                                                             SURFACE FINISH =
+                                              -     MATERIAL:                                  DRAWN BY:        DATE:  DWG. NO.                                                                                           FRONT EXHAUWSTeiOghUtTDOWOeRig(hWt O) 63 MICROINCH MINIMUMTITLE:
+                                                                                 25 30 35 DO NOT SCALE DRAWING.
+                                                                                               CAH                       40SK475405A 50
+                                                                                 REMOVE ALL BURRS, BREAK
+                                                                                 SHARP EDGES.
+                                                                                 APPLICABLE STANDARDS: DIM.
+                                                                                 AND TOL. ANSI Y14.5
+                                                                      20                                    10/19/16                                          55                                     60
+
+                                                    FINISH:                                    CHECKED BY:      DATE:                                                                                    "W"        "L" "H" MATERIAL:            "H" "D" DO NOT SCALE DRAWING.  DRAWN BY:      DATE:  DWG. NO.
+                                                                                                                                                                                                                                                    REMOVE ALL BURRS, BREAK                    DATE:
+                                           DATE BY                                             --           --         SCALE:1:16  SIZE A SHEET 1 OF 1                                                                                                                                                HDG-400-M-W
+
+                                                                                                                                                                                                                                                 SHARP EDGES.
+                                                                                                                                                                                                                                                 APPLICABLE STANDARDS: DIM. CHECKED BY:
+                                                                                                                                                                                                                                 FINISH:         AND TOL. ANSI Y14.5                                                       SIZE A SHEET 1 OF 1
+                                                                                                                                                                      LEVEL DESCRIPTION OF REVISION           DATE                                                                                    SCALE:1:16
+                                                                                                                                                                                                                    BY
+                                                                                               Nom. Duct Opening Airflow (CFM)
+MBH Qty. Btuh                                 Btuh                                                                                                                                                       inch inch inch inch inch                                                              lb                          lb
+
+50 3 50,000 40,000 1852 1481 1235 1058 926 823 741 673 617 15.7                                                                                                                                                                                                                                127                207
+
+75 3 75,000 60,000 2778 2222 1852 1587 1389 1235 1111 1010 926 15.7                                                                                                                                                                                                                            127                207
+
+100 4 100,000 80,000 3704 2963 2469 2116 1852 1646 1481 1347 1235 18.4                                                                                                                                                                                                                         142                222
+                                                                                                                                                                             5
+                                                                                                                                                                                                                                                                                               169                249
+125 5 125,000 100,000 4630 3704 3086 2646 2315 2058 1852 1684 1543 21.2
+
+150 6 150,000 120,000 5556 4444 3704 3175 2778 2469 2222 2020 1852 23.9                                                                                                                                                                                                                        160                240
+
+175 7 175,000 140,000 6481 5185 4321 3704 3241 2881 2593 2357 2160 26.7 47.8 22.9 34.9                                                                                                                                                                                                         180                260
+
+200 8 200,000 160,000 7407 5926 4938 4233 3704 3292 2963 2694 2469 29.4                                                                                                                                                                                                                        196                276
+
+250 10 250,000 200,000 9259 7407 6173 5291 4630 4115 3704 3367 3086 34.9                                                                                                                                                                                                                       245                325
+
+300 12 300,000 240,000 11111 8889 7407 6349 5556 4938 4444 4040 3704 40.4                                                                                                                                                                                             6                        279                384
+
+350 14 350,000 280,000 12963 10370 8642 7407 6481 5761 5185 4714 4321 45.9                                                                                                                                                                                                                     324                429
+
+400 15 400,000 320,000 14815 11852 9877 8466 7407 6584 5926 5387 4938 48.7                                                                                                                                                                                                                     394                499
+
+Note: For a single furnace, 20° F minimum temperature rise, 60° F maximum temperature rise.
+
+INDIRECT GAS-FIRED DUCT FURNACE DIMENSIONS
+
+                                                                                                                                                                                                         NOTES
+                                                                                                                                                                                                         1. UNLESS OTHERWISE SPECIFIED,
+
+                                                                                                                                                                                                                 DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                 NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                         2. SPECIFICATIONS SUBJECT TO
+                                                                                                                                                                                                                 CHANGE WITHOUT NOTICE.
+
+                                                                                        36"
+                                                                                 Service Area
+
+                                                                                                                              TOP VIEW                                                                                                           47 7/8"
+                                                                                                                                                                                                                                                  Case
+
+  14 7/8"                                                                                                                                                                                                Case                                                                                          14 7/8"
+Opening                                                                                                                                                                                                                                                                                               Opening
+                                                                                                                                                                                                         37" (WO) Shown
+6 1/8"                                                                                                                                                                                                                                                                                                    6 1/8"
+                                                                                                                                                              View Port                                  25" (NO)
+
+                                                                      24"                                                                                     3/8" Condensate                                           24"
+                                                                  Opening Power Wiring and                                                                    Drain Tube                                            Opening
+
+                                             3"                                  Control Wiring                                                   3/4" Gas Connection                                                                       3"
+                                           LEFT VIEW                             Inlet Fittings                               FRONT VIEW
+                                                                                                                                                                                                                                   RIGHT VIEW
+
+                                                                                                                              UNLESS OTHERWISE SPECIFIED,     RenewAire LLC                                                               Specifications  may   be     subject              to  change without 4510 Helgesen Dr.  notice.
+                                                                                                                              DIMENSIONS ARE IN INCHES.                                                                                                                                           Madison, WI 53718 USA
+                                                                                                                              TOLERANCES:                                                                                                                                                             TEL: (608) 221-4499
+                                                                                                                              LINEAR 0.015                                                                                                                                                            FAX: (608) 221-2824
+                                                                                                                              HOLE SIZE 0.005                                                                                                                                                  TOLL FREE: (800) 627-4499
+                                                                                                                              ANGULARITY 3
+                                                                                                                              SURFACE FINISH =                FOTIRTLET:HE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM                                                                                                                        139
+
+                                                                                                                                  63 MICROINCH MINIMUM        FRONT EXHAUST OUTDOOR (WO)DIM SPEC
+
+                                                                                                                                                                                                                    DRAWN BY:             DATE:          DWG. NO.
+CERTIFICATIONS & PERFORMANCE
+
+AHRI 1060
+
+CERTIFIED PERFORMANCE
+
+Energy recovery component certified in accordance with AHRI Standard 1060-2013.
+Actual performance in packaged equipment may vary.
+
+                                        AHRI-1060 Certified Performance - Model Number L125-G5
+
+              Type                           Tilt Angle                           Nominal Airflow                                         Pressure Drop
+              Plate                             N/A
+                                                                                  100% - 750 SCFM                                        0.65 in. H20
+                   Leakage Ratings                                                75% - 563 SCFM
+
+                                                                             Thermal Effectiveness Ratings at 0" Pressure Differential
+
+ Pressure     EATR                OACF  Purge Angle or       Nominal Airflow  Sensible Latent   Total   Net      Net                       Net           Net
+Differential                                Setting                                                   Airflow  Sensible                   Latent         Total
+-1 in. H20
+              1.0%                1.00  N/A             750 Heating          70%  52%          64%    750     70%                        52%            64%
+ 0 in. H20
+                                                        CFM Cooling          70%  42%          53%    CFM     70%                        42%            53%
+ 1 in. H20
+              0.0%                1.02  N/A
+
+                                                        563 Heating          74%  59%          69%    563     74%                        59%            69%
+
+              0.0%                1.05  N/A             CFM Cooling          74%  49%          58%    CFM     74%                        49%            58%
+
+                                        AHRI-1060 Certified Performance - Model Number L85-G5
+
+              Type                           Tilt Angle                           Nominal Airflow                                         Pressure Drop
+
+              Plate                                     N/A                       100% - 500 SCFM                                        0.65 in. H20
+                   Leakage Ratings                                                75% - 375 SCFM
+
+                                                                             Thermal Effectiveness Ratings at 0" Pressure Differential
+
+ Pressure     EATR                OACF  Purge Angle or       Nominal Airflow  Sensible Latent   Total   Net      Net                       Net           Net
+Differential                                Setting                                                   Airflow  Sensible                   Latent         Total
+-1 in. H20
+              1.0%                1.00  N/A             500 Heating          70%  52%          64%    500     70%                        52%            64%
+ 0 in. H20
+                                                        CFM Cooling          70%  42%          53%    CFM     70%                        42%            53%
+ 1 in. H20
+              0.0%                1.02  N/A
+
+                                                        375 Heating          74%  59%          69%    375     74%                        59%            69%
+
+              0.0%                1.05  N/A             CFM Cooling          74%  49%          58%    CFM     74%                        49%            58%
+
+                                        AHRI-1060 Certified Performance - Model Number L62-G5
+
+              Type                           Tilt Angle                           Nominal Airflow                                         Pressure Drop
+
+              Plate                                     N/A                       100% - 350 SCFM                                        0.65 in. H20
+                   Leakage Ratings                                                75% - 263 SCFM
+
+                                                                             Thermal Effectiveness Ratings at 0" Pressure Differential
+
+ Pressure     EATR                OACF  Purge Angle or       Nominal Airflow  Sensible Latent   Total   Net      Net                       Net           Net
+Differential                                Setting                                                   Airflow  Sensible                   Latent         Total
+-1 in. H20
+              1.0%                1.00  N/A             350 Heating          70%  52%          64%    350     70%                        52%            64%
+ 0 in. H20
+                                                        CFM Cooling          70%  42%          53%    CFM     70%                        42%            53%
+ 1 in. H20
+              0.0%                1.02  N/A
+
+                                                        263 Heating          74%  59%          69%    263     74%                        59%            69%
+
+              0.0%                1.05  N/A             CFM Cooling          74%  49%          58%    CFM     74%                        49%            58%
+
+NOTE: SCFM = Standard Cubic Feet per Minute OACF = Outdoor Air Correction Factor EATR = Exhaust Air Transfer Ratio N/A = Not Applicable
+
+140 RENEWAIRE.COM 1.800.627.4499
+                                                                                                                                                                               ORDERING & SUPPORT
+
+                                EV450/HE MODEL
+                           CONFIGURATION GUIDE
+
+                                 Note: Not all options are available on every model.
+
+MODEL NUMBER                                     J              -             --                                                                                            -
+
+DIGIT NUMBER    123        4               567                  8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
+
+Digits 1 - 5: Model                                                Digit 18:  Flow Control* (see Restrictions 11, 12, & 14)
+"EV450", "HE-1X", "HE1.5","HE-2X",
+"HE-3X", "HE-4X", "HE-6X, "HE-8X"                                  "-" = No Isolation Dampers (with no Bypass)
+                                                                   "D" = Motorized Damper both Airstreams (with no Bypass)
+ Digits 7 - 8: Location                                            "E" = Motorized Damper EA or RA Airstream (with no Bypass)
+"IN" = Indoor                                                      "F" = Motorized Damper FA or OA Airstream (with no Bypass)
+"RT" = Rooftop                                                     "S" = Backdraft Damper OA Airstream (with no Bypass)
+                                                                   "R" = Backdraft Damper EA Airstream (with no Bypass)
+Digit 9:        Orientation (see Restriction 1)                    "B" = Backdraft Damper both Airstreams (with no Bypass)
+                                                                   "T" = Motorized Damper OA, Backdraft Damper EA (with no Bypass)
+"V", "H" (Indoor Units)                                            "0" = Dry Bulb Bypass Dampers only
+"V", "H", "R", "F", "C" (Rooftop Units)                            "1" = Dry Bulb Bypass with Motorized Dampers all Airstreams
+"-" = Default in EV450                                             "4" = Dry Bulb Bypass with Backdraft Damper OA Airstream
+                                                                   "5" = Enthalpy Bypass Dampers only
+ Digit 11:      Wall Type                                          "6" = Enthalpy Bypass with Motorized Dampers all Airstreams
+"S" = Single                                                       "9" = Enthalpy Bypass with Backdraft Damper OA Airstream
+"D" = Double
+                                                                   Digit 19:  Unit Control (see Restrictions 8, 9, 10, 15, & 16)
+
+Digit 12:       Phase (see Restriction 7)                          "A" = Standard Unit Control Wiring
+                                                                   "D" = Independent Blower Control (HE-1X and HE1.5 only)
+"1" = Single Phase                                                 "V" = Onboard VFD Both Airstreams
+"3" = Three Phase                                                  "F" = Onboard VFD FA Airstream
+                                                                   "E" = Onboard VFD EA Airstream
+Digit 13:       Voltage (see Restrictions 2, 3, 4, 5, 6 & 18))     "G" = Terminal Strip for EC Motors or Impellers
+
+"1" = 115V                                                         Digit 20:  Unit Fusing
+"4" = 460V
+"5" = 208-230V                                                     "N" = Non-Fused (Standard)
+"8" = 575V                                                         "F" = Fused
+"9" = 277V
+
+Digit 14:       FA Horsepower (see Restriction 7 & 18)             Digit 21:  Unit Control Enhancements (see Restrictions 16 & 17)
+
+"-" = Standard EV450 Motors                                        "T" = Transformer with Isolation Relay (Standard)
+"H" = 0.75 HP Standard Direct-Drive Motors (HE-1X only)            "1" = Enhanced Controls
+"E" = EC Direct Drive Motors (EV450, HE-1X and HE1.5 only)         "2" = Premium Controls
+"S" = Standard Impellers (HE1.5 only)                              "3" = Enhanced Controls with BACNET License
+"U" = 1.5HP (HE-2X only)                                           "4" = Premium Controls with BACNET License
+"V" = 2HP (HE-2X, HE-3X, HE-4X only)
+"W" = 3HP (HE-3X, HE-4X only)                                      Digit 22:  Filter Options (see Restriction 17)
+"X" = 5HP (HE-3X, HE-4X, HE-6X, HE-8X only)
+"Y" = 7.5HP (HE-6X, HE-8X only)                                    "-" = None
+"Z" = 10HP (HE-8X only)                                            "F" = Filter Monitor Both Airstreams
+
+                                                                   Digit 23:  Other Options
+
+Digit 15:       EA Horsepower (see Restriction 7 & 18)             "-" = None (Reserved)
+
+"-" = Standard EV450 Motors                                        Digit 24:  Paint and Customization
+"H" = 0.75 HP Standard Direct-Drive Motors (HE-1X only)
+"E" = EC Direct Drive Motors (EV450, HE-1X and HE1.5 only)         "-" = None
+"S" = Standard Impellers (HE1.5 only)                              "W" = White Paint
+"U" = 1.5HP (HE-2X only)                                           "C" = Custom Paint
+"V" = 2HP (HE-2X, HE-3X, HE-4X only)                               "X" = Custom Unit
+"W" = 3HP (HE-3X, HE-4X only)
+"X" = 5HP (HE-3X, HE-4X, HE-6X, HE-8X only)                        Digit 25:  Safety Listing (see Restriction 13)
+"Y" = 7.5HP (HE-6X, HE-8X only)
+"Z" = 10HP (HE-8X only)                                            "L" = Listed
+                                                                   "N" = Non-Listed
+
+*NOTES:
+Digit 6 "J" = G5 Core Type Digits 10, 16 and 17 are not used in these models. Digit 15 is not used in EV450 models.
+*Digit 18: Flow Control: Codes for Bypass: Face damper also acts as Isolation damper in EA or RA Airstream.
+
+Restrictions:
+ 1: Orientation Code "C" not available with models EV450, HE-6X, HE-8X, HE1.5
+ 2: Voltage Codes "1" & "9" only available with Phase Code "1" (Single-Phase).
+ 3: Voltage Codes "4" & "8" only available with Phase Code "3" (Three-Phase).
+ 4: Voltage Code "9" (277V) only available with EV450, HE-1X & HE1.5 models.
+ 5: Voltage Code "8" (575V) not available with EV450, HE-1X & HE1.5 models.
+ 6: Voltage Code "1" only available with FA/EA Horsepower Codes "EE", "E-", "H", "S","U", "V" & "-".
+ 7: Motor Codes "E-" & "EE" (EC Motors) only available with Phase Code "1" (Single Phase)
+ 8: Unit Control Codes " V, F & E" not available in EV450, HE-1XIN, HE1.5IN & HE-1XRTC.
+ 9: Unit Control Code "G" (Terminal Strip) only available in EV450, HE-1X & HE1.5 with Motor Codes "E-" and "EE" (EC Motors).
+ 10: Unit Control Code "D" only available in HE-1X & HE1.5.
+ 11: Dampers and Bypass not available in EV450 or with Orientation Code "C".
+ 12: Backdraft Dampers only available with HE1.5 models.
+ 13: Some units with Customization Code "X", HE-6X & HE-8X models are not safety listed.
+ 14: Bypass only available with Location Code "IN".
+ 15: Unit Control Codes "V", "E" & "F" not available with Voltage Code "1".
+ 16: Unit Control "A" not available with Unit Control Enhancements Codes "1", "2", "3" & "4" in HE-1X and HE-1.5 models.
+ 17: Filter Code "F" not available with Unit Control Enhancements Codes "1", "2", "3" & "4". Filter Monitor is provided with those options.
+ 18: Voltage Code "9" not available with FA/EA Horsepower Codes "EE" & "E-".
+
+                           ForToTePclhanciecCaalnOSMOurpMdpeEorRrEtC-EmIE-AmVaLial&:PilR:RHReOEneDenMweUwOaCiaDrTeiErOeCLSrOSdueDprEpso@CrtrH@eAnreeRwnTeawiraei.rceo.mcom
+
+                                                                   FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 141
+ORDERING & SUPPORT
+
+         EK SERIES ELECTRIC DUCT HEATER
+                     CONFIGURATION GUIDE
+
+                                  Note: Not all options are available on every model.
+
+MODEL NUMBER                 -
+
+DIGIT NUMBER    123                  4      567                8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
+
+Digits 1 - 2: Heater Type                                                                        Digit 18:   Voltage (see Restrictions 7 & 8)
+"EK "= Electric Heater (Standard)                                                              "1" = 120V
+                                                                                               "2" = 208V
+ Digits 4 - 5:  Width in Inches (see Restriction 1)                                            "3" = 240V
+08-99                                                                                          "4" = 480V
+                                                                                               "8" = 600V
+                                                                                               "9" = 277V
+
+ Digits 6 - 7:  Height in Inches (see Restriction 2)                                           Digit 19:     Phase
+08-99
+                                                                                               "1" = Single-Phase
+ Digits 8 - 10: Capacity in kW (see Restrictions 3, 4 & 5)                                     "3" = Three-Phase
+001-175
+                                                                                                Digit 20:    Power Fusing (see Restriction 9)
+                                                                                               "-" = None
+Digit 11:       Mount                                                                          "F" = Fusing
+
+"S" = Slip In (Standard)                                                                       Digit 21:     Stage
+"F = Flanged
+
+Digit 12:       Element Style                                                                  "1" = Single (Standard)
+                                                                                               "2" = 2-Stage
+"C" = Open Coil (Standard)                                                                     "4" = 4-Stage
+
+Digit 13:       Element Material                                                               Digit 22:     Control Voltage
+
+"C" = 60-20-20 Ni-Cr-Fe with Nickel Plate Terminal Pins (Standard)                             "S" = 24VAC
+"A" = 80-20 Ni-Cr with Stainless Steel Terminal Pins
+
+Digit 14:       Airflow Orientation                                                            Digit 23:     Control Type (see Restrictions 10, 11 & 12)
+
+"H" = Horizontal (Standard)                                                                    "D" = Duct Thermostat with Sensor (Standard)
+"V" = Vertical                                                                                 "E" = Electronic Step Control with Sensor
+                                                                                               "S" = SCR (For BAS System)
+Digit 15:       Control Box Offset                                                             "V" = SCR with Analog Sensor (0-10Vdc)
+
+"L" = Left Hand (Standard)                                                                     Digit 24:     Time Delay
+"R" = Right Hand
+
+                                                                                               "-" = None (Standard)
+
+Digit 16:       Control Box Recessed
+
+"-" = None (Standard)                                                                          Digit 25:     Pilot Light
+"R" = Recessed 1"
+                                                                                               "N" = None (Standard)
+Digit 17:       Control Box Dust Tight                                                         "L" = Light
+
+"-" = None (Standard)
+"D" = Dust Tight
+
+*NOTES:
+Digit 3 is not used in this model.
+All heaters come with standard features: Disconnect Switch, Air Flow Switch (non adjustable), Control Transformer
+Descriptions of feature and options are found in the installation and operation manual.
+
+Restrictions:
+
+1: Width inches entered as a whole number.
+2: Height inches entered as a whole number.
+3: Heater density should be less than 30kW/ft². DENSITY= HEATER CAPACITY (kW) < 30
+                                                                     (W" x H")/144
+4: Heater capacity kW entered as a whole number.
+5: Formulas for calculating kW and temperature rise: kW = CFM x ΔT             ΔT = kW x 3150
+                                                      3150                          CFM
+7: Voltage Codes "1" & "9" only available with Phase Code "1" (Single-Phase).
+8: Voltage Codes "4" & "8" only available with Phase Code "3" (Three-Phase).
+9: Power Fusing Code "F" required when amperage is >48A. (based on kW and voltage)
+10: Control Type Code "D" only available with Stage Code "1" & "2".
+11: Control Type Code "E" only available with Stage Code "4".
+12: Control Type Code "S" & "V" only available with Stage Code "1", unless amperage is greater than or equal to 96A, then Stage Code "4" is automatically selected.
+
+                                             For TechnicEalLSEupCpoTrtREI-CmaPil:OReSnTewHairEeSAuTpport@renewaire.com
+                                               ToCPOlacNeFanIGOUrdeRr AE-TmIaOil:NReCneOwaDireEOrCdeHrsA@RreTnewaire.com
+
+142 RENEWAIRE.COM 1.800.627.4499
+                                                                                                                                                                              ORDERING & SUPPORT
+
+GH SERIES INDIRECT GAS-FIRED DUCT
+    FURNACE CONFIGURATION GUIDE
+
+                          Note: Not all options are available on every model.
+
+MODEL NUMBER                 -                                                                                -                                               --
+
+DIGIT NUMBER      123                  4  567  8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
+
+Digits 1 - 2: Duct Furnace Type                                              Digit 17:     Disconnect Switch
+"GH" = Gas Furnace 50-400 MBH
+                                                                             "N" = None (Standard)
+                                                                             "D" = Disconnect Switch
+
+ Digits 4 - 5: Location                                                       Digit 18:    System/Inducer Voltage (see Restriction 2)
+"IN" = Indoor                                                                "1" = 115V
+"RT" = Rooftop                                                               "2" = 208V
+                                                                             "3" = 230V
+  Digits 6 - 7: Vent Location
+"SI" = Separated Top Indoor                                                  Digit 19:     Phase
+"KI" = Top Exhaust Indoor
+"WO" = Front Exhaust Outdoor                                                 "1" = Single Phase
+"NO" = Top Exhaust Outdoor
+                                                                              Digit 20:    Power Fusing (see Restriction 3)
+                                                                             "N" = None
+  Digits 8 - 10: Input Capacity in MBH                                       "F" = Fusing
+"050", "075", "100", "125", "150", "175", "200", "250", "300", "350", "400"
+
+                  Fuel Type                                                  Digit 22:     Control Voltage
+
+Digit 11:                                                                    "S" = 24VAC
+
+"N" = Natural Gas (Standard)                                                 Digit 23:     Control Type (see Restriction 1)
+"P" = Propane
+
+Digits 12 - 13: Tube Material                                                "T" = Two Stage High/Low with Thermostat (Standard)
+"SS" = 409 Stainless Steel (Standard)                                        "S" = Single Stage On/Off with Thermostat
+"CS" = 304 Stainless Steel                                                   "E" = Modulating 5:1 (Natural Gas)/3:1 (Propane) with Thermostat
+                                                                             "W" = Modulating 10:1 (Natural Gas)/6:1 (Propane) with Thermostat
+Digit 14:         Airflow Orientation                                        "2" = Two Stage High/Low without Thermostat
+                                                                             "1" = Single Stage On/Off without Thermostat
+"H" = Horizontal                                                             "M" = Modulating 5:1 (Natural Gas)/3:1 (Propane) without Thermostat
+                                                                             "V" = Modulating 10:1 (Natural Gas)/6:1 (Propane) without Thermostat
+                  Thermal Efficiency
+ Digit 15:
+"S" = 80%
+
+Digit 16:         Elevation
+
+"S" = 0 - 2000' (Standard)
+"2" = 2001'- 3000'
+"3" = 3001' - 4000'
+"4" = 4001' - 5000'
+"5" = 5001' - 6000'
+"6" = 6001' - 7000'
+"Y" = 7001' and above
+
+*NOTE:
+Digits 3, 21, 24 & 25 are not used in this model.
+All heaters come with standard features: Air Proving Switch, Auxiliary High Temperature Limit Switch
+Descriptions of feature and options are found in the installation and operation manual.
+
+Restrictions:
+ 1: Control Type Code "V" & "W" not available with Input Capacity in MBH Codes "050", "075", "100", "125", "150" & "175".
+ 2: System/Inducer Voltage Code "2" not available with Input Capacity in MBH Codes "050", "075", "100", "125" , "150", "175" & "200".
+ 3. Power Fusing Code “F” only available with Disconnect Switch Code “D”. Power Fusing Code “F” always selected when Disconnect Switch Code “D” is selected.
+
+                                                 GAS HEAT CONFIGURATION
+                                          For Technical SuppCoOrt DE-EmaCil:HRAenRewTaireSupport@renewaire.com
+
+                                            To Place an Order E-mail: RenewaireOrders@renewaire.com
+
+                                                                                                         FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 143
+ORDERING & SUPPORT
+
+                    INDOOR AIR QUALITY MATTERS
+
+                    u Deficient IAQ is an EPA top-five health risk
+
+                    u People spend 90% of their time indoors
+
+                    u Indoor air can be 2-5 times and up to 100 times
+                       more polluted than outdoor air
+
+BENEFITS OF INCREASED VENTILATION
+
+                                  BETTER          IMPROVED   INCREASED
+                                  HEALTH          COGNITIVE  PRODUCTIVITY
+                                                  FUNCTION
+
+TECHNICAL/APPLICATIONS SUPPORT
+The goal of our technical-support team is to provide the BEST CUSTOMER SERVICE
+in the HVAC industry. You can count on our knowledgeable and seasoned staff for all your technical,
+application and service needs, and we’ll respond quickly and effectively to answer any of your questions.
+
+                    CONTACT RENEWAIRE
+
+                                  PHONE:          FOR TECHNICAL SUPPORT:
+                                  1.800.627.4499  RenewaireSupport@renewaire.com
+
+                                  FAX:            TO PLACE AN ORDER:
+                                  608.221.2824    RenewaireOrders@renewaire.com
+
+144 RENEWAIRE.COM 1.800.627.4499
+RELEVANT                                                           RENEWAIRE
+
+EVERYWHERE                                                  TEMPERS THE AIR
+
+EVERY GEOGRAPHIC REGION                                    Our ERVs moderate the extremes
+Our ERVs function perfectly across the world in every      of outdoor supply-air temperature
+geographic region.                                         and humidity year-round, providing
+                                                           a sustainable solution for fresh air
+EVERY CLIMATE                                              that feels like a perfect spring day.
+Our ERVs operate in every climate—from Alaska to
+Florida, and everywhere in between.
+
+EVERY PROJECT
+From massive skyscrapers to cozy residential homes,
+our ERVs can be used in every size project and in every
+code jurisdiction.
+
+APPLIED EVERYWHERE
+
+When indoor occupants breathe in unclean air, this harms their health and causes cognitive impairment. Our ERVs can
+provide cleaner and healthier indoor air for every type of building in the world, thus improving occupants’ wellbeing,
+while also reducing energy costs.
+
+RESIDENTIAL                                                DAYCARE
+The increased airtightness of newer and remodeled          Crowded daycare facilities breed deficient IAQ, thus
+homes is causing deficient IAQ, resulting in more health   causing health problems for everyone—especially
+problems for indoor occupants.                             children who are more vulnerable.
+
+COMMERCIAL                                                 EDUCATION (LOWER AND HIGHER)
+As commercial buildings become more airtight,              With students and teachers packed into tight classrooms,
+deficient IAQ is increasing and causing sickness,          instances of deficient IAQ go up, resulting in academic
+absenteeism and decreased productivity.                    performance and test scores going down.
+
+H E A LT H C A R E                                         GOVERNMENT
+The high occupant density of hospitals, nursing homes      Aging and crowded government buildings result in
+and other healthcare facilities results in deficient IAQ   deficient IAQ, which can impair worker performance
+and ensuing health problems for patients and staff alike.  and productivity.
+
+RESTAURANTS/COFFEE SHOPS                                   EVERY TYPE OF BUILDING
+The large volume of indoor occupants in restaurants        Every type of building can benefit from the enhanced
+and coffee shops causes deficient IAQ and subsequent       IAQ generated by RenewAire ERVs, including
+health problems.                                           veterinary clinics, nail salons and manufacturing
+                                                           facilities, among others.
+RETAIL
+The high level of foot traffic in retail stores leads
+to deficient IAQ and the potential sickness of shoppers,
+which can negatively impact sales.
+        RENEWAIRE EVERYWHERE                                       LIT114_00 (01/19)
+
+       RenewAire ERVs can be applied everywhere across all
+         commercial, educational, institutional, light industrial
+
+      and residential buildings. Our technology excels in every
+     geographic region, every climate, and every size project.
+
+Member of the S&P Group
+Family of Brands
+ERV
+                        LE SERIES
+
+                                      COMMERCIAL ERV CATALOG
+
+JANUARY 2019
+
+RENEWAIRE.COM | 800.627.4499
+BECAUSE INDOOR
+
+AIR QUALITY MATTERS
+
+As buildings become more airtight due to better                                                 application of ERV technologies. Deficient IAQ is a
+construction methodologies, the need for increased                                              serious problem, especially considering:
+and balanced ventilation is critical. Without it, internally                                    u	On average, Americans spend 90% of their time indoors
+generated contaminants accumulate and cause deficient                                           u	The EPA found that indoor air may be 2-5 times—and
+indoor air quality (IAQ), which leads to significant
+health and cognitive problems for occupants. Industry                                              occasionally greater than 100 times—more polluted
+standards are changing to combat deficient IAQ, and                                                than outdoor air
+codes that adopt these new standards are driving the                                            u	The EPA ranks indoor air pollutants as a top-five
+                                                                                                   environmental health risk to occupants
+
+HEALTH    PRODUCTIVITY                                                                          LEARNING
+MAT TERS  MAT TERS                                                                              MAT TERS
+
+ADVERSE EFFECTS                                                                                 ABOUT RENEWAIRE
+
+O F DEFICIENT IAQ                                                                               For over 30 years, RenewAire has been
+                                                                                                a pioneer in enhancing IAQ in commercial and
+Deficient IAQ has numerous adverse effects on the                                               residential buildings of every size. This is achieved
+health and cognitive function of building occupants.                                            while maximizing sustainability through our fifth-
+                                                                                                generation, enthalpic-core, static-plate Energy
+                  Health problems: Acute allergies,                                            Recovery Ventilators (ERVs) that optimize energy
+                  headaches, coughs, asthma, skin                                               efficiency, lower capital costs via HVAC load
+                  irritations and breathing difficulties,                                       reduction and decrease operational expenses
+                  as well as chronic illnesses such as                                          by minimizing equipment needs, resulting
+                  cancer, liver disease, kidney damage                                          in significant energy savings. Our ERVs are
+                  and nervous-system failure.                                                   competitively priced, simple to install, easy to use
+                                                                                                and maintain, have a quick payback and enjoy the
+                  Cognitive impairment: Studies by the                                         industry’s best warranty with the lowest claims
+                  Harvard School of Public Health and the                                       due to long-term reliability. In 2010, RenewAire
+                  Lawrence Berkeley National Laboratory                                         joined the Soler & Palau (S&P) Ventilation Group,
+                  found that carbon dioxide (CO )—an                                            providing direct access to the latest in energy-
+                                                                                                efficient air-moving technologies. For more
+                                                                                             2  information, visit: renewaire.com.
+
+                  indoor air contaminant—negatively impacted
+                  thinking and decision-making at levels
+                  commonly found inside homes and buildings.
+                                                                                                                                                                                            TABLE OF CONTENTS
+
+                                TABLE OF
+
+CONTENTS
+
+LE SERIES - Commercial Unitary ERV
+
+MODEL                TYPE     CFM RANGE         PAGE
+LE6XINH - STANDARD   Indoor   1,500-6,600 CFM     4-5
+LE6XINV - STANDARD   Indoor   1,500-6,600 CFM     6-7
+LE6XRT - STANDARD    Rooftop  1,500-6,600 CFM    8-10
+LE8XINH - STANDARD   Indoor   2,000-8,800 CFM
+LE8XINV - STANDARD   Indoor   2,000-8,800 CFM   12-13
+LE8XRT - STANDARD    Rooftop  2,000-8,800 CFM   14-15
+LE10XINH - STANDARD  Indoor   2,500-11,000 CFM  16-18
+LE10XINV - STANDARD  Indoor   2,500-11,000 CFM  20-21
+LE10XRT - STANDARD   Rooftop  2,500-11,000 CFM  22-23
+                                                24-26
+
+ABOUT RENEWAIRE                                   2-3
+SPECIFICATIONS & DIMENSIONS                      4-26
+OPTIONS & ACCESSORIES                           27-39
+CERTIFICATIONS & PERFORMANCE
+ORDERING & SUPPORT                                  40
+                                                41-44
+
+                              FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 1
+   ABOUT RENEWAIRE
+
+   R E N E WA I R E E R Vs
+
+   ACHIEVE SUSTAINABLE IAQ
+
+   RenewAire is a pioneer in enhancing IAQ while maximizing sustainability through enthalpic-core, static-plate Energy
+   Recovery Ventilators (ERVs) that optimize energy efficiency, lower costs by reducing HVAC loads and therefore
+   reduce environmental footprints. Our ERV technology preconditions incoming air with the otherwise-wasted energy
+   (heat and humidity) of the exhaust air going out—all while the airstreams are kept physically separate as certified by
+   the Air Conditioning, Heating and Refrigeration Institute (AHRI) for zero exhaust air transfer at normal balanced operating
+   conditions. As the pioneer of static-plate core technology in North America, RenewAire is the largest ERV producer in the USA.
+
+   OPTIMIZING                                               OA  COOLING SEASON    RA        OA  HEATING SEASON         RA
+   ENERGY EFFICIENCY
+                                                                       EFFICIENT                       EFFICIENT
+   Energy efficiency is optimized by preconditioning            HEAT & HUMIDITY                 HEAT & HUMIDITY
+   the outside air coming in with the otherwise-wasted
+   heat and humidity of the exhaust air going out. This                TRANSFER                        TRANSFER
+   exchange of energy moderates temperatures and moisture,
+   decreases HVAC equipment needs, drives operational       EA                    FA        EA                         FA
+   efficiencies and conserves energy.
+
+   REDUCING HVAC LOADS                                                                               INSIDE                  OUTSIDE
+                                                                                                Fresh Air Enters       Stale Room Air Exits
+   RenewAire technology reduces HVAC loads during both winter and summer. In turn,
+   HVAC equipment size and needs can be decreased and furnaces and air conditioners           Fixed Partition
+   can be smaller. This process ensures efficient operations and keeps both energy use and  and Spacer Plates
+   costs low, while at the same time maintaining high-level IAQ.
+                                                                                               (proprietary resin
+                                                                                            and composite media)       Outside Air
+
+                                                                                                       Stale Room Air
+
+   MINIMIZING ENVIRONMENTAL IMPACT
+
+   The combination of less energy used and HVAC loads being reduced conserves resources. Further, our Madison, WI plant
+   is 100% powered by renewable wind energy, and is one of the few buildings worldwide to be LEED and Green Globes
+   certified, as well as having achieved ENERGY STAR Building status. This commitment to sustainable manufacturing
+   minimizes our overall production and distribution environmental footprint.
+
+2
+                                                                                                                                                                                                    ABOUT RENEWAIRE
+
+WHY RENEWAIRE
+
+IS PREFERRED
+
+                  BEST VALUE
+
+                       u Priced competitively against other ERV models
+                       u Due to competitive pricing and decreased costs, payback is short and ROI is maximized
+                       u Contractors can pass these significant savings along to their customers
+
+                  RELIABLE OPERATION
+
+                       u Built-to-last ERVs have lifespans of 25+ years and operate consistently year-round in every extreme,
+                          including frost-free performance in all but the most severe winter climates
+
+                       u High-efficiency core operates dry in all conditions, meaning no condensate pans
+                       u An industry-leading ten-year warranty for the static-plate core, two-year warranty for commercial
+
+                          products and a five-year warranty for residential products
+                       u Superior product quality results in paramount reliability and longevity
+
+                  HIGHEST-QUALITY INDOOR AIR
+
+                       u Stale indoor air is replaced with fresh, conditioned and filtered air from
+                          the outside, resulting in Enhanced IAQ by removing harmful contaminants
+
+                       u Airstreams do not mix and pollutants are not transferred across partition plates
+                       u No biocide used; material does not promote biological growth
+                       u Moderated temperatures and humidity maintain a comfortable indoor environment
+
+                  OPTIMIZED ENERGY EFFICIENCY
+
+                       u Efficient heat and humidity transfer recaptures up to 70-80% of the energy exhausted in the airstream
+                       u Energy that’s otherwise wasted by conventional ventilation systems (such as bath fans) is reused,
+
+                          thus dramatically reducing monthly operation costs
+                       u Energy-efficient operation decreases HVAC loads, which cuts down on energy use and costs
+                       u The hotter or colder the climate, the more energy is recovered
+
+                  HIGHLY CERTIFIED
+
+                       u See individual catalog submittal for certification details:
+                                 u UL u cUL u ETL u HVI u AHRI
+
+                                                                                                                                                                                                                                     3
+SPECIFICATIONS & DIMENSIONS
+
+HLE 6XINH                                                       Energy Recovery Ventilator
+                                                                Standard
+
+INDOOR UNIT                                                     SPECIFICATIONS                                                                 Options:
+                                                                                                                                               Spring vibration isolators
+                      LE6XINV shown                             Ventilation Type:                                                              Onboard variable frequency drives (VFDs) -
+Download specification at:                                      Static plate, heat and humidity transfer
+renewaire.com/specifications                                                                                                                      one or both airstreams
+AIRFLOW PERFORMANCE                                             Typical Airflow Range: 1,500-6,600 CFM                                          Shaft grounding ring on motors with VFDs
+                                                                                                                                               Fused disconnect
+                                                                AHRI 1060 Certified Core: Six L125-G5                                           Integrated programmable controls -
+
+                                                                Standard Features:                                                                enhanced, premium
+                                                                TEFC Premium efficiency motors                                                  Class 1 low leakage motorized isolation dampers -
+                                                                Motor starters
+                                                                Non-fused disconnect                                                              OA, RA or both airstreams
+                                                                24 VAC transformer/relay package                                               Qty. 2, Factory mounted filter alarms -
+                                                                Cross-core differential pressure ports
+                                                                                                                                                  both airstreams
+                                                                Filters: Total qty. 12, MERV 8: 20" x 25" x 2"                                 Double wall construction
+                                                                                                                                               Exterior paint - white, custom colors
+                                                                Unit Dimensions & Weight:
+                                                                81 1/2" L x 125 1/2" W x 71 1/4" H                                             Accessories:
+                                                                Modular (per module) 943-1,367 lbs., varies by option(s)                       Filters - MERV 13, 2" or 4"; MERV 8, 4" (shipped loose)
+                                                                Assembled (1-piece) 1,975-2,630 lbs., varies by option(s)                      Digital time clock - wall mount (TC7D-W),
+
+                                                                Max. Shipping Dimensions & Weight (on pallet):                                    in exterior enclosure (TC7D-E)
+                                                                Modular (2-modules) 80" L x 90" W x 78" H                                      Carbon dioxide sensor/control -
+
+                                                                   Module 1 - 1,508 lbs., Module 2 - 1,406 lbs.                                   wall mount (CO2-W), duct mount (CO2-D)
+                                                                Assembled (1-piece) 160" L x 90" W x 78" H -                                   IAQ sensor - wall mount (IAQ-W),
+
+                                                                   2,630 lbs.                                                                     duct mount (IAQ-D)
+                                                                                                                                               Motion occupancy sensor/control -
+                                                                Motor(s):
+                                                                Qty. 2, Belt drive blower/standard motor packages                                 ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                               Smoke Detector - duct mount (SD-D)
+                                                                   with choice of adjustable sheaves for low,                                  Electric duct heater - EK series (1–175 kW)
+                                                                   medium or high blower speed (see table below)                               Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                  (50-400 MBH), installed downstream of any fans
+
+                                                                                       External Static Pressure (in.w.g.)
+
+Airflow             0.00          0.25                   0.50                           0.75             1.00          1.25                          1.50       1.75            2.00
+ CFM           BHP RPM       BHP RPM
+                                                        BHP RPM BHP RPM BHP RPM BHP RPM                                                        BHP RPM BHP RPM BHP RPM
+ 1500          2.1 770       2.0 780
+ 2000          2.4 810       2.2 820                                                                    3 HP LOW SPEED                              3 HP MED SPEED        3 HP HIGH SPEED
+ 2500          2.7 850       2.5 850
+ 3000          3.0 880       2.8 890                                                         0.9 820 1.1 900                                   1.3 960 1.4 1020 1.6 1080
+ 3500          3.4 910       3.2 920
+ 3750          3.8 950       3.5 950                                                         1.1 850 1.3 930                                   1.5 990 1.7 1050 1.9 1100
+ 4000          4.2 980       3.9 980
+ 4250          4.6 1000      4.3 1000                                1.1 770 1.3 870 1.5 950                                                   1.7 1010 1.9 1060 2.1 1110
+ 4500          5.1 1030      4.8 1030
+ 4750          5.3 1040      5.2 1060                                1.4 800 1.6 890 1.8 960                                                   2.0 1020 2.2 1080 2.4 1130
+ 5000                        5.4 1070
+ 5250                                                         Therm1a.7l Perf8o4r0manc1e.9Ratin9g1s0G5 220.15.2.x9l8sx0                        2.4 1040 2.6 61C0o90res (I2O.8M) 1140
+ 5500
+ 5750                                                   1.7 780 1.9 860 2.1 920 2.3 990                                                        2.6 1040 2.8 1100 3.1 1150              5 HP
+ 6000                                                                                                                                                                                  MED
+ 6250                                                   1.9 810 2.1 880 2.3 940 2.6 1000                                                       2.8  1050  3.0       1110  3.3  1160   SPEED
+ 6500                                                                                                                                          3.0  1060  3.3       1120  3.6  1170
+  6600                                                  2.2 840 2.3 900 2.6 960 2.8 1010
+
+         3 HP                                           2.4 870 2.6 920 2.8 970 3.1 1030                                                       3.3 1080 3.6 1130 3.9 1180
+         LOW
+        SPEED                                           2.7 900 2.9 950 3.1 990 3.3 1040                                                       3.6 1090 3.9 1140 4.2 1190 5 HP
+
+         5 HP                                           3.0 930 3.2 970 3.4 1010 3.7 1060                                                      3.9 1110 4.2 1150 4.5 1210 HIGH
+         LOW
+        SPEED                                           3.4 960 3.5 990 3.8 1030 4.0 1080                                                      4.3 1120 4.6 1170 4.9 1220 SPEED
+
+                                                        3.7 980 3.9 1020 4.1 1060 4.4 1100                                                     4.7 1140 5.0 1190 5.4 1240
+
+                                                        4.1 1010 4.3 1040 4.5 1080 4.8 1120                                                    5.1 1160 5.4 1200 5.8 1260
+
+                                                        4.5 1030 4.7 1070 5.0 1100 5.2 1140                                                    5.5 1180 5.9 1220 6.3 1270
+
+                                                        5.0 1060 5.2 1090 5.4 1120 5.7 1160                                                    6.0 1190 6.3 1240 6.8 1290
+
+                                                        5.4 1080 5.6 1110 5.9 1140 6.2 1170                                                    6.5 1210 6.8 1250 7.3 1300
+
+                                                        5.6 1090 5.8 1120 6.1 1150 6.4 1180                                                    6.7 1220 7.0 1260 7.5 1310
+
+                                                        7.5 HP LOW SPEED                                                                                  7.5 HP MED SPEED
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                             CORE PERFORMANCE
+
+           Standard Electrical Specifications                          Optional Factory Installed                                                                 Airflow (CFM)
+                                                                     VFD Electrical Specifications
+                                                                                                                                                    1000 2000 3000 4000 5000 6000 7000
+                                                        Max.                                                  Max.          Effectiveness (%)  90%
+
+HP  Volts  HZ  Phase     FLA         Min. Cir.          Overcurrent     FLA                  Min. Cir.  Overcurrent                            70%
+                      per motor       Amps              Protection   per motor                Amps      Protection
+                                                                                                                                               50%
+                                                        Device                                                Device
+                                                                                                                                               30%
+3.0 208-230 60 Single 14.7-14 33.1                      40           9.38-8.48 40.2                           45                                        At AHRI 1060 standard conditions.
+                                                                                                                                                        See all AHRI certified ratings at www.ahrinet.org.
+    208-230 60 Three 9.38-8.48 21.1                     25           9.38-8.48 23.2                           25
+
+3.0 460 60 Three 4.24                9.5                15           4.24                    10.5             15
+
+    575 60 Three         3.3         7.4                15           3.3                     8.2              15
+
+    208-230 60 Three 14.5-13.4 32.6                     45           14.5-13.4 35.9                           45
+
+5.0 460 60 Three         6.7         15.1               20           6.7                     16.6             20
+
+    575 60 Three         5.3         11.9               15           5.3                     13.1             15
+
+    208-230 60 Three 21.0-19.0 47.3                     60           21.0-19.0 52.0                           60
+
+7.5 460 60 Three         9.5         21.4               25           9.5                     23.5             25
+
+    575 60 Three         7.6         17.1               20           7.6                     18.8             20
+
+Specifications may be subject to change without notice.
+
+4 RENEWAIRE.COM 1.800.627.4499
+                                                                     LE6XINH Energy Recovery Ventilator Standard
+
+                                                                                                                                                                                                           69 3/4" Minimum                                                  ABBREVIATIONS
+                                                                                                                                                                                                             Service Area                                                   EA: Exhaust Air to outside
+                                                                                                                                                                                                                                                                            OA: Outside Air intake
+                                                                                                                                                                                                           Door   Door                                                      RA: Room Air to be exhausted
+                                                                                                                                                                                                           Swing  Swing                                                     FA: Fresh Air to inside
+                                                                                                                                                                                                                                                                            INSTALLATION ORIENTATION
+                                                                                                                                                                                                    EA                                   OA                                 Unit must be installed in orientation
+                                                                                                                                                                                                                                                                            shown.
+                                                                                                                                                                                                    FA                                   RA                                 NOTE
+                                                                                                                                                                                                                                                                            1.UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                                            DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                                            NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                                            2.SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                                            TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                                                                                            3. MIN. DUCT CLEARANCE
+                                                                                                                                                                                                                                                                            FROM DAMPER BLADES WHEN FULLY
+                                                                                                                                                                                                                                                                            OPENED TO BE 2". SMACNA RULES
+                                                                                                                                                                                                                                                                            APPLY.
+
+                                                                                                                                                                                        36" E-Box          Door   Door                   60 1/4" Minimum
+                                                                                                                                                                                        Minimum            Swing  Swing                     Blower Service
+                                                                                                                                                                                      Service Area
+                                                                                                                                                                                                                                                Area Typ.
+                                                                                                                                                                                                                                                            OA Inlet
+                                                                                  13 3/8" X 15 1/2"                                                                                                            111" Minimum                                 32" X 24"                         OA Damper
+                                                                                                                                                                                                                Service Area                                Duct Receiving                    Location
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 5                  Electrical                                                                                                                                                             Flange                            (Optional)
+                                                                                                                                                                                                                   TOP VIEW
+                                                                     32" X 24"       Connection             44 5/8"
+                                                                                                                                                                                                                       81 1/2" Overall
+                                                                     Duct Receiving  Cover                                                                          25 1/4"                                                  5" Damper                                      125 3/8" Overall
+                                                                                                                                                                        E-Box                                               Frames Typ.                                      122 5/8" Case
+                                                                     Flange Typ.                                                                                                                                                         Pressure
+                                                                                                                                                                     Disconnect                     EA                                   Ports (4) Typ.
+                                                                     71 1/8" Overall                                                                                 Switch                                                                                 RA Damper
+                                                                           69 5/8" Case                                                                                                                                                  OA                 Location
+                                                                                 41 3/8"                                                                                                                                                                    (Optional)
+                                                                                                    8 3/4"
+                                                                                                                                                                             53 1/2"                                                                        8 3/4"                            41 1/2"
+
+                                                                                                                                                                                                    FA                                    RA
+
+                                                                     25 1/4"                                 CL 11 3/8"                                             29 5/8"           2" Duct Flange        69 1/8" Case                 4"                                 RA Inlet          25 1/4"
+                                                                                                            (5) 1 1/8"                                                                                                                   2" Typ.                            32" X 24"
+                                                                                                            Knockouts                                                                                Typ.      CL 73 3/8"                                                   Duct Receiving
+                                                                                                                                                                     CL 5 1/4"                 CL 2 1/4"        Lift Lugs                                   25 1/4"         Flange
+                                                                                                                                                                    (2) 7/8"                    Wiring
+                                                                                                                                                                    Knockouts                              FRONT VIEW
+
+                                                                                             LEFT VIEW                                                                                                                                                                      RIGHT VIEW
+                                                                     MDAArovaIaRdiwlaFebiLlnel:OagLsWEsTh6yoCwXpOnIeNiNn:HdFUimIGneniUtsiRoDnAidmTraIwOeinNng.sion
+                                                                     Version: MAY18                                                                                                                                                                                         UNIT MOUNTING & APPLICATION
+
+                                                                                                                                                                                                                                                                            Must be mounted as shown. RA/EA airstream can
+                                                                                                                                                                                                                                                                            be switched with OA/FA airstream unless certain
+                                                                                                                                                                                                                                                                            options are selected.
+
+                                                                                                                                                                                                           LE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HLE 6XINV                                                       Energy Recovery Ventilator
+                                                                Standard
+
+INDOOR UNIT                                                     SPECIFICATIONS
+
+Download specification at:                                      Ventilation Type:                                                             Options:
+renewaire.com/specifications                                    Static plate, heat and humidity transfer                                      Spring vibration isolators
+                                                                                                                                              Onboard variable frequency drives (VFDs) -
+AIRFLOW PERFORMANCE                                             Typical Airflow Range: 1,500-6,600 CFM
+                                                                                                                                                 one or both airstreams
+                                                                AHRI 1060 Certified Core: Six L125-G5                                          Shaft grounding ring on motors with VFDs
+                                                                                                                                              Fused disconnect
+                                                                Standard Features:                                                            Integrated programmable controls -
+                                                                TEFC Premium efficiency motors
+                                                                Motor starters                                                                   enhanced, premium
+                                                                Non-fused disconnect                                                          Class 1 low leakage motorized isolation dampers -
+                                                                24 VAC transformer/relay package
+                                                                Cross-core differential pressure ports                                           OA, RA or both airstreams
+                                                                                                                                              Qty. 2, Factory mounted filter alarms -
+                                                                Filters: Total qty. 12, MERV 8: 20" x 25" x 2"
+                                                                                                                                                 both airstreams
+                                                                Unit Dimensions & Weight:                                                     Double wall construction
+                                                                81 1/2" L x 125 1/2" W x 71 1/4" H                                            Exterior paint - white, custom colors
+                                                                Modular (per module) 715-1,622 lbs., varies by option(s)
+                                                                Assembled (1-piece) 1,984-2,640 lbs., varies by option(s)                     Accessories:
+                                                                                                                                              Filters - MERV 13, 2" or 4"; MERV 8, 4" (shipped loose)
+                                                                Max. Shipping Dimensions & Weight (on pallet):                                Digital time clock - wall mount (TC7D-W),
+                                                                Modular (2-modules) 80" L x 90" W x 78" H
+                                                                                                                                                 in exterior enclosure (TC7D-E)
+                                                                   Module 1 - 1,763 lbs., Module 2 - 1,159 lbs.                               Carbon dioxide sensor/control -
+                                                                Assembled (1-piece) 160" L x 90" W x 78" H -
+                                                                                                                                                 wall mount (CO2-W), duct mount (CO2-D)
+                                                                   2,922 lbs.                                                                 IAQ sensor - wall mount (IAQ-W),
+
+                                                                Motor(s):                                                                        duct mount (IAQ-D)
+                                                                Qty. 2, Belt drive blower/standard motor packages                             Motion occupancy sensor/control -
+
+                                                                   with choice of adjustable sheaves for low,                                    ceiling mount (MC-C), wall mount (MC-W)
+                                                                   medium or high blower speed (see table below)                              Smoke Detector - duct mount (SD-D)
+                                                                                                                                              Electric duct heater - EK series (1–175 kW)
+                                                                                                                                              Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                 (50-400 MBH), installed downstream of any fans
+
+                                                                                       External Static Pressure (in.w.g.)
+
+Airflow             0.00             0.25                0.50                           0.75        1.00              1.25                          1.50       1.75            2.00
+ CFM           BHP RPM          BHP RPM
+                                                        BHP RPM BHP RPM BHP RPM BHP RPM                                                       BHP RPM BHP RPM BHP RPM
+ 1500                           2.0 780
+ 2000                           2.2 820                                                            3 HP LOW SPEED                                  3 HP MED SPEED        3 HP HIGH SPEED
+ 2500                           2.5 850
+ 3000                           2.8 890                                                      0.9 820 1.1 900                                  1.3 960 1.4 1020 1.6 1080
+ 3500                           3.2 920
+ 3750                           3.5 950                                                      1.1 850 1.3 930                                  1.5 990 1.7 1050 1.9 1100
+ 4000                           3.9 980
+ 4250                           4.3 1000                             1.1 770 1.3 870 1.5 950                                                  1.7 1010 1.9 1060 2.1 1110
+ 4500                           4.8 1030
+ 4750                           5.2 1060                              1.4 800 1.6 890 1.8 960                                                 2.0 1020 2.2 1080 2.4 1130
+ 5000                           5.4 1070                      Therm1a.l7Perfo84rm0 ance1.9Rating91s0G5 202.115.2.x9ls8x0                      2.4 1040 2.6 61C0o9r0es (IO2.8M) 1140
+ 5250
+ 5500                                                   1.7 780 1.9 860 2.1 920 2.3 990                                                       2.6 1040 2.8 1100 3.1 1150              5 HP
+ 5750                                                                                                                                                                                 MED
+ 6000                                                   1.9 810 2.1 880 2.3 940 2.6 1000                                                      2.8  1050  3.0       1110  3.3  1160   SPEED
+ 6250                                                                                                                                         3.0  1060  3.3       1120  3.6  1170
+ 6500                                                   2.2 840 2.3 900 2.6 960 2.8 1010
+  6600
+         3 HP  2.1 770                                  2.4 870 2.6 920 2.8 970 3.1 1030                                                      3.3 1080 3.6 1130 3.9 1180
+         LOW
+        SPEED  2.4    810                               2.7 900 2.9 950 3.1 990 3.3 1040                                                      3.6 1090 3.9 1140 4.2 1190 5 HP
+               2.7    850
+                                                        3.0 930 3.2 970 3.4 1010 3.7 1060                                                     3.9 1110 4.2 1150 4.5 1210 HIGH
+
+               3.0 880                                  3.4 960 3.5 990 3.8 1030 4.0 1080                                                     4.3 1120 4.6 1170 4.9 1220 SPEED
+
+         5 HP  3.4 910                                  3.7 980 3.9 1020 4.1 1060 4.4 1100                                                    4.7 1140 5.0 1190 5.4 1240
+         LOW
+        SPEED  3.8    950                               4.1 1010 4.3 1040 4.5 1080 4.8 1120                                                   5.1 1160 5.4 1200 5.8 1260
+               4.2    980
+                                                        4.5 1030 4.7 1070 5.0 1100 5.2 1140                                                   5.5 1180 5.9 1220 6.3 1270
+
+               4.6 1000                                 5.0 1060 5.2 1090 5.4 1120 5.7 1160                                                   6.0 1190 6.3 1240 6.8 1290
+
+               5.1 1030                                 5.4 1080 5.6 1110 5.9 1140 6.2 1170                                                   6.5 1210 6.8 1250 7.3 1300
+
+               5.3 1040                                 5.6 1090 5.8 1120 6.1 1150 6.4 1180                                                   6.7 1220 7.0 1260 7.5 1310
+
+                                                        7.5 HP LOW SPEED                                                                                 7.5 HP MED SPEED
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.                                      CORE PERFORMANCE
+ELECTRICAL DATA
+
+           Standard Electrical Specifications                                            Optional Factory Installed                                              Airflow (CFM)
+                                                                                       VFD Electrical Specifications
+                                                                                                                                                   1000 2000 3000 4000 5000 6000 7000
+                                                        Max.                                             Max.              Effectiveness (%)  90%
+
+HP  Volts  HZ  Phase     FLA Min. Cir.                  Overcurrent     FLA Min. Cir.              Overcurrent                                70%
+                      per motor Amps                    Protection   per motor Amps                Protection
+                                                                                                                                              50%
+                                                        Device                                           Device
+                                                                                                                                              30%
+3.0 208-230 60 Single 14.7-14 33.1                      40           9.38-8.48 40.2                      45                                            At AHRI 1060 standard conditions.
+                                                                                                                                                       See all AHRI certified ratings at www.ahrinet.org.
+    208-230 60 Three 9.38-8.48 21.1                     25           9.38-8.48 23.2                      25
+
+3.0 460 60 Three 4.24           9.5                     15           4.24                    10.5        15
+
+    575 60 Three           3.3  7.4                     15                             3.3   8.2         15
+
+    208-230 60 Three 14.5-13.4 32.6                     45           14.5-13.4 35.9                      45
+
+5.0 460 60 Three           6.7  15.1                    20                             6.7   16.6        20
+
+    575 60 Three           5.3  11.9                    15                             5.3   13.1        15
+
+    208-230 60 Three 21.0-19.0 47.3                     60           21.0-19.0 52.0                      60
+
+7.5 460 60 Three           9.5  21.4                    25                             9.5   23.5        25
+
+    575 60 Three           7.6  17.1                    20                             7.6   18.8        20
+
+Specifications may be subject to change without notice.
+
+6 RENEWAIRE.COM 1.800.627.4499
+                                                                     LE6XINV Energy Recovery Ventilator Standard
+
+                                                                                                                                                                                                      69 3/4" Minimum                                                 ABBREVIATIONS
+                                                                                                                                                                                                        Service Area                                                  EA: Exhaust Air to outside
+                                                                                                                                                                                                                                                                      OA: Outside Air intake
+                                                                                                                                                                                                      Door   Door             34"                                     RA: Room Air to be exhausted
+                                                                                                                                                                                                      Swing  Swing       Minimum                                      FA: Fresh Air to inside
+                                                                                                                                                                                                                       Service Area                                   INSTALLATION ORIENTATION
+                                                                                                                                                                                                                                                                      Unit must be installed in orientation
+                                                                                                                                                                                           RA                          OA                                             shown.
+                                                                                                                                                                                                                                                                      NOTE
+                                                                                                                                                                                           FA                          EA                                             1.UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                                      DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                                      NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                                      2.SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                                      TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                                                                                      3.MIN. DUCT CLEARANCE FROM
+                                                                                                                                                                                                                                                                      DAMPER BLADES WHEN FULLY
+                                                                                                                                                                                                                                                                      OPENED TO BE 2". SMACNA RULES
+                                                                                                                                                                                                                                                                      APPLY.
+
+                                                                                                                                                                               36" E-Box              Door   Door      60 1/4" Minimum
+                                                                                                                                                                               Minimum                Swing  Swing        Blower Service
+                                                                                                                                                                             Service Area
+                                                                                                                                                                                                                              Area Typ.
+                                                                                                            13 3/8" X 15 1/2"                                                                                                                                                                   OA Inlet
+                                                                                RA Inlet  RA Damper         Electrical                                                                                111" Minimum                                                                              32" X 24"
+                                                                              32" X 24"   Location          Connection                                                                                 Service Area                                                                             Duct Receiving
+                                                                     Duct Receiving       (Optional)        Cover                                                                                                                                                                               Flange
+                                                                                                                                                                                                           TOP VIEW
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 7              Flange                     44 5/8"                                                                                                                                                   125 3/8" Overall
+                                                                                                                                                                                                                                                                       122 5/8" Case
+                                                                                                                                                                    25 1/4"           Pressure        81 1/2" Overall                               32" X 24"
+                                                                                                                                                                        E-Box         Ports (4) Typ.                                      Duct Receiving
+                                                                                                                                                                       Disconnect                          5" Damper
+                                                                                                                                                                       Switch                             Frames Typ.                          Flange Typ.
+
+                                                                     71 1/8" Overall                                                                                                       RA                          OA                              25 1/4"
+                                                                          69 5/8" Case
+                                                                                41 1/2"                                                                                      53 1/2"       FA                          EA                                     8 3/4"              41 1/2"
+                                                                                                    8 3/4"
+                                                                     25 1/4"                                 CL 11 3/8"                                             29 5/8"                    2"     69 1/8" Case     4"                                             OA Damper   25 1/4"
+                                                                                                            (5) 1 1/8"                                                                     CL 2 1/4"                     2" Typ.                                      Location
+                                                                                                            Knockouts                                                CL 5 1/4"              Wiring      CL 73 3/8"                                                    (Optional)
+                                                                                                                                                                    (2) 7/8"                             Lift Lugs
+
+                                                                                                                                                                    Knockouts
+
+                                                                                             LEFT VIEW                                                                                                FRONT VIEW                                                      RIGHT VIEW
+                                                                     MDroaAAdvwIaReilianFlb:LlgeLOaETsW6yshXpoCIweNOn:ViNnUdFnimIGitenUDsiRoinmAdTreaIwOninNsgi.on
+                                                                     Version: MAY18                                                                                                                                                                                   UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                                                                                                      Must be mounted as shown. RA/EA airstream can
+                                                                                                                                                                                                                                                                      be switched with OA/FA airstream unless certain
+                                                                                                                                                                                                                                                                      options are selected.
+
+                                                                                                                                                                                                      LE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HLE 6XRT                                                               Energy Recovery Ventilator
+                                                                       Standard
+
+ROOFTOP UNIT                                                           SPECIFICATIONS
+
+                                           LE10XRT shown               Ventilation Type:                                                           Options:
+Download specification at:                                             Static plate, heat and humidity transfer                                    Spring vibration isolators
+renewaire.com/specifications                                                                                                                       Onboard variable frequency drives (VFDs) -
+                                                                       Typical Airflow Range: 1,500-6,600 CFM
+AIRFLOW PERFORMANCE                                                                                                                                   one or both airstreams
+                                                                       AHRI 1060 Certified Core: Six L125-G5                                        Shaft grounding ring on motors with VFDs
+                                                                                                                                                   Fused disconnect
+                                                                       Standard Features:                                                          Integrated programmable controls -
+                                                                       TEFC Premium efficiency motors
+                                                                       Motor starters                                                                 enhanced, premium
+                                                                       Non-fused disconnect                                                        Class 1 low leakage motorized isolation dampers -
+                                                                       24 VAC transformer/relay package
+                                                                       Cross-core differential pressure ports                                         OA, RA or both airstreams
+                                                                                                                                                   Qty. 2, Factory mounted filter alarms -
+                                                                       Filters:
+                                                                       Total qty. 12, MERV 8: 20" x 25" x 2"                                          both airstreams
+                                                                                                                                                   Double wall construction
+                                                                       Unit Dimensions & Weight:                                                   Exterior paint - white, custom colors
+                                                                       111 1/4" L x 125 1/2" W x 71 1/4" H
+                                                                       Modular (per module) 1,069-1,461 lbs., varies by option(s)                  Accessories:
+                                                                       Assembled (1-piece) 2,086-2,753 lbs., varies by option(s)                   Filters - MERV 13, 2" or 4"; MERV 8, 4" (shipped loose)
+                                                                                                                                                   Roof curb - standard 14"
+                                                                       Max. Shipping Dimensions & Weight (on pallet):                              Curb wind clip
+                                                                       Modular (2-modules) 80" L x 90" W x 78" H                                   Engineered combo curb for Carrier RTU
+                                                                                                                                                   Engineered combo curb for Trane RTU
+                                                                          Module 1 - 1,602 lbs., Module 2 - 1,491 lbs.                             Digital time clock - wall mount (TC7D-W),
+                                                                       Assembled (1-piece) 160" L x 90" W x 78" H -
+                                                                                                                                                      in exterior enclosure (TC7D-E)
+                                                                          3,035 lbs.                                                               Carbon dioxide sensor/control -
+
+                                                                       Motor(s):                                                                      wall mount (CO2-W), duct mount (CO2-D)
+                                                                       Qty. 2, Belt drive blower/standard motor packages                           IAQ sensor - wall mount (IAQ-W),
+
+                                                                          with choice of adjustable sheaves for low,                                  duct mount (IAQ-D)
+                                                                          medium or high blower speed (see table below)                            Motion occupancy sensor/control -
+
+                                                                                                                                                      ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                                   Smoke Detector - duct mount (SD-D)
+                                                                                                                                                   Electric duct heater - EK series (1–175 kW);
+
+                                                                                                                                                      designed for indoor ductwork installation only
+                                                                                                                                                   Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                      (50-400 MBH), installed downstream of any fans
+
+                                                                                            External Static Pressure (in.w.g.)
+
+Airflow                0.00           0.25                      0.50         0.75                  1.00                    1.25                          1.50  1.75   2.00
+ CFM
+                 BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM
+
+                                                                                            3 HP LOW SPEED                3 HP MED SPEED                             3 HP HIGH SPEED
+
+1500                                                                                        0.9 840 1.1 920 1.5 990 1.9 1060 2.4 1120
+
+2000                                                                   0.9 770 1.1 860 1.4 940 1.7 1010 2.2 1080 2.6 1140
+
+2500                                                                   1.1 800 1.3 880 1.7 950 2.0 1030 2.4 1090 2.9 1150
+
+3000                                                                 Therm1.4al Per8f3o0rman1c.e7 Rating9s00G5 2021.50.2.xl9s7x0 2.3 1040 2.7 1611C0ore3s.1(IOM11)70 5 HP MED
+
+3500                                                      1.6 800 1.8 870 2.1 930 2.4 1000 2.7 1060 3.1 1120 3.5 1190
+
+3750                            1.6 760 1.8 820 2.0 890 2.3 950 2.6 1010 2.9 1070 3.3 1130 3.7 1190
+
+4000                            1.8 790 2.0 850 2.3 910 2.5                                             970          2.8  1030                     3.2  1090 3.5 1150 3.9 1200        5 HP HIGH
+                                                                                                        990          3.1  1040                     3.4  1100 3.7 1160 4.1 1210          SPEED
+4250     3 HP    1.9 770 2.1 820 2.3 880 2.5 930 2.8
+         LOW
+4500    SPEED    2.2    800     2.4  850                  2.6  900     2.8             960  3.1         1010 3.4 1060 3.7 1110 4.0 1170 4.3 1230
+4750             2.5    840     2.7  880                  2.9  930     3.1             980  3.4
+                                                                                                        1030 3.7 1080 4.0 1130 4.3 1180 4.6 1240
+
+5000             2.8 870 3.0 910 3.2 960 3.5 1000 3.7                                                   1050 4.0 1100 4.3 1150 4.6 1200 4.9 1250
+
+5250             3.2 910 3.4 940 3.6 990 3.8 1030 4.1 1070 4.3 1120 4.6 1170 4.9 1220 5.3 1270
+
+5500 5 HP 3.6 940 3.8 970 4.0 1010 4.2 1050 4.5 1090 4.7 1140 5.0 1180 5.3 1230 5.6 1290
+
+5750 LOW 4.0 970 4.2 1000 4.4 1040 4.6 1080 4.9 1120 5.1 1160 5.4 1200 5.7 1250 6.0 1300
+
+6000 SPEED 4.4 1000 4.6 1030 4.8 1070 5.0 1100 5.3 1140 5.5 1180 5.8 1230 6.1 1270 6.4 1330
+
+6250             4.9 1030 5.1 1060 5.3 1090 5.5 1130 5.7 1160 6.0 1200 6.2 1250 6.5 1300 6.9 1350
+
+6500             5.3 1060 5.5 1090 5.7 1120 6.0 1150 6.2 1190 6.4 1230 6.7 1270 7.0 1320 7.4 1380
+
+6600             5.5 1070 5.7 1100 5.9 1130 6.1 1160 6.4 1200 6.6 1240 6.9 1280 7.2 1330 7.5 1390
+
+                            7.5 HP LOW SPEED                                                                                                       7.5 HP MED SPEED
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.                                     CORE PERFORMANCE
+ELECTRICAL DATA
+
+             Standard Electrical Specifications                                          Optional Factory Installed                                            Airflow (CFM)
+                                                                                       VFD Electrical Specifications
+
+                                                               Max.                                     Max.                    Effectiveness (%)       1000 2000 3000 4000 5000 6000 7000
+                                                                                                                                                   90%
+HP    Volts  HZ  Phase         FLA Min. Cir.              Overcurrent     FLA Min. Cir.           Overcurrent
+                            per motor Amps                Protection   per motor Amps             Protection                                       70%
+
+                                                               Device                                   Device
+
+3.0 208-230 60 Single 14.7-14 33.1                             40      9.38-8.48 40.2                   45
+
+    208-230 60 Three 9.38-8.48 21.1                            25      9.38-8.48 23.2                   25                                         50%
+
+3.0 460 60 Three 4.24                      9.5                 15           4.24            10.5        15                                         30%
+                                                                                                                                                             At AHRI 1060 standard conditions.
+        575 60 Three         3.3           7.4                 15                      3.3  8.2         15                                                   See all AHRI certified ratings at www.ahrinet.org.
+
+    208-230 60 Three 14.5-13.4 32.6                            45      14.5-13.4 35.9                   45
+
+5.0 460 60 Three             6.7           15.1                20                      6.7  16.6        20
+
+        575 60 Three         5.3           11.9                15                      5.3  13.1        15
+
+    208-230 60 Three 21.0-19.0 47.3                            60      21.0-19.0 52.0                   60
+
+7.5 460 60 Three             9.5           21.4                25                      9.5  23.5        25
+
+        575 60 Three         7.6           17.1                20                      7.6  18.8        20
+
+Specifications may be subject to change without notice.
+
+8 RENEWAIRE.COM 1.800.627.4499
+                                                                     LE6XRT (RTV/RTR) Energy Recovery Ventilator Standard
+
+                                                                                                                                                                                                                69 3/4" Minimum                   ABBREVIATIONS
+                                                                                                                                                                                                                  Service Area                    EA: Exhaust Air to outside
+                                                                                                                                                                                                                                                  OA: Outside Air intake
+                                                                                                          CURB LE6X                                                   FA (RTV)                                  Door   Door       RA              RA: Room Air to be exhausted
+                                                                                                                                                           16 1/8" X 19 1/2"                                    Swing  Swing      24" X 32"       FA: Fresh Air to inside
+                                                                                                                                                                                                                                  Opening         RTV: Rooftop Vertical RA & FA
+                                                                                                          64 1/4" O.D.                                               Opening                                                                      RTR: Rooftop Vertical RA Only
+                                                                                                                                                                                                                                    OA            INSTALLATION ORIENTATION
+                                                                                                       A                A                                         EA                                                                              Unit must be installed in orientation
+                                                                                                                                                                                                                                    OA            shown.
+                                                                                        115 1/4" O.D.                     9 1/2"                       36" E-Box                                                49 5/8"                           NOTE:
+                                                                                             33"                                                       Minimum                                                     18 3/8"                        1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                  Service Area                                                                                    DIMENSIONS ARE ROUNDED TO THE
+                                                                                                     20"                  25"                                                                                                                     NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                  2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                          FA    RA                                                          46"                41"                                                TO CHANGE WITHOUT NOTICE.
+
+                                                                                                                                                                            Minimum            Area Typ.        Door   Door       RA Damper       CURB CROSS-SECTION A-A (TYP.)
+                                                                                                                                                                               Blower Service                   Swing  Swing      Location
+                                                                                                                                      3"                           60 1/4"                                                        (Optional)
+                                                                                        17 1/4"             60 1/2" I.D.                                                                                                                          1 1/2" X 1/4"               1 7/8"
+                                                                                                                                                                                                                                      19 5/8"     Neoprene Gasket
+                                                                                                          TOP VIEW                                                                                                                      Typ.
+                                                                                                                                                                                                                111" Minimum                      3/4" X 3 1/2"
+                                                                                                              13 3/8" X 15 1/2"                                                                                 Service Area      Pressure Ports  Wooden Nailer                       14"
+                                                                                                                                                                                                                                  (4) Typ.
+                                                                                                              Electrical                                                                                             TOP VIEW                                             3"
+                                                                                                                                                                                                                                     2" Typ.
+                                                                                                              Connection                                                                                                                                 SECTION A-A
+                                                                                                              Cover
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 9  EA Outlet                                                            E-Box
+
+                                                                                                                                          Disconnect                                                            111 1/8" Overall                                   125 3/8" Overall
+                                                                                                                                                                                                                  69 1/4" Case                                      122 5/8" Case
+                                                                                                              44 5/8"      8 7/8"         Switch                                 22 1/4"
+                                                                                                                               53 1/2"
+                                                                     71 1/8" Overall
+                                                                          65 5/8" Case                                                                                                         FA          RTR
+                                                                              4"                                                                                                                          ONLY
+
+                                                                     FA (RTR)                             25 1/4"           CL 5 1/4"                                               2" Duct                           73 3/8"                       OA Inlets,
+                                                                     32" X 24"                                             (2) 7/8"                                              Flange Typ.                        Lifting Lugs                  OA Damper
+                                                                     Duct Receiving                        CL 11 3/8"      Knockouts
+                                                                     Flange                                (5) 7/8"                                                                                                                                 Locations
+                                                                                                          Knockouts                                                                                             FA                                 (Optional)
+                                                                                                                                                                                                                 RTV        RA
+                                                                                                                                                                                                                ONLY                              RIGHT VIEW
+
+                                                                                                     LEFT VIEW                            HERT except 6x 8x, LERT                              HERT except 6x 8x, LERT                            UNIT MOUNTING & APPLICATION
+                                                                                                                                                                                                                                                  Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                                           FRONT VIEW                             be switched.
+
+                                                                     MoAdIReFl:LLOEW6XCORTNVF/IGRUTRRATION                                        RTV                                                     RTR
+                                                                     DraAwvailianblge asTsyhpowen:: Unit Dimension
+                                                                                                                                          EA                       OA            EA                             OA
+
+                                                                     Version: MAY18                                                                                                            FA
+
+                                                                                                                                                  FA                                                      RA
+                                                                                                                                                         RA
+
+                                                                                                                                                                                                                LE-SERIES
+                                                                                                                                                                                                                                                                                                                                     SPECIFICATIONS & DIMENSIONS
+10 RENEWAIRE.COM 1.800.627.4499
+LE6XRT (RTH/RTF) Energy Recovery Ventilator Standard
+
+                                                                                                                                                    69 3/4" Minimum                                            ABBREVIATIONS
+                                                                                                                                                      Service Area                                             EA: Exhaust Air to outside
+                                                                                                                                                                                                               OA: Outside Air intake
+                                     CURB LE6X                                                                                                                                                                 RA: Room Air to be exhausted
+                                                                                                                                                                                                               FA: Fresh Air to inside
+                                     64 1/4" O.D.                                                         FA ( RTF)                                 Door   Door                                                RTF: Rooftop Vertical FA Only
+                                                                                               16 1/8" X 19 1/2"                                    Swing  Swing                                               RTH: Rooftop Horizontal RA & FA
+                                                                                                                                                                                                               INSTALLATION ORIENTATION
+                                  A                 A                                                    Opening                                                                                               Unit must be installed in orientation
+                                                                                                                                                                                                               shown.
+                   115 1/4" O.D.                     9 1/2"                                          EA                                                                       OA                               NOTE:
+                        33"                                                                                                                                                   OA                               1. UNLESS OTHERWISE SPECIFIED,
+                                20"                  25"                                  36" E-Box                                                     18 3/8"                                                DIMENSIONS ARE ROUNDED TO THE
+                                                                                          Minimum                                                                                                              NEAREST EIGHTH OF AN INCH.
+                                     FA    RA                                        Service Area                                                                                                              2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                               TO CHANGE WITHOUT NOTICE.
+                                                                                                                46"
+
+                   17 1/4"                                       3"                                             Minimum            Area Typ.        Door   Door                           CURB CROSS-SECTION A-A (TYP.)
+                                       60 1/2" I.D.                                                                Blower Service                   Swing  Swing
+                                                                                                       60 1/4"
+                                     TOP VIEW                                                                                                                                             1 1/2" X 1/4"                     1 7/8"
+                                                                                                                                                                                          Neoprene Gasket
+
+                                                                                                                                                    111" Minimum                          3/4" X 3 1/2"
+                                                                                                                                                    Service Area                          Wooden Nailer
+
+                                                                                                                                                          TOP VIEW                                                3"
+                                         13 3/8" X 15 1/2"                                                                                                                                                   8 3/4"
+                                                                                                                                                        111 1/8" Overall                                                                                   14"
+                                         Electrical                                                                                                        69 1/4" Case                                        SECTION A-A
+
+                                         Connection
+
+EA Outlet                                Cover                                E-Box
+
+                                                                              Disconnect                                                                                                                   RA  125 3/8" Overall
+                                                                                                                                                                                                   32" X 24"    122 5/8" Case
+                                           44 5/8"                   53 1/2"  Switch                                 22 1/4"                                              19 5/8"         Duct Receiving
+                                                                                                                                                                            Typ.
+71 1/8" Overall                                                                                                                                                                                      Flange
+     65 5/8" Case                                                                                                                                                         Pressure Ports
+         4"                                            8 3/4"                                                                                                             (4) Typ.
+
+                                                                                                                                   FA          RTH                        RA
+                                                                                                                                              ONLY
+
+FA (RTH)                             25 1/4"                          CL 5 1/4"                                         2" Duct                           73 3/8"              2" Typ.    25 3/8"                            OA Inlets,
+32" X 24"                                                            (2) 7/8"                                        Flange Typ.                       Lifting Lugs                                                         OA Damper
+Duct Receiving                        CL 11 3/8"                     Knockouts                                                                                            5" Damper              RA Damper
+Flange                                (5) 7/8"                                                                                                      FA                    Frames Typ.            Location                    Locations
+                                     Knockouts                                                                                                                                                   (Optional)                  (Optional)
+                                                                                                                                                     RTF
+                                                                                                                                                    ONLY
+
+                                LEFT VIEW                                     HERT except 6x 8x, LERT                              FRONT VIEW HERTexcept 6x 8x, LERT                                           RIGHT VIEW
+
+MoAdIReFl:LLOEW6XCORTNHF/IGRUTFRATION                                                 RTH                                                     RTF                                                              UNIT MOUNTING & APPLICATION
+DraAwvailianblge asTsyhpowen:: Unit Dimension                                                                                                                                                                  Must be mounted as shown. Airstreams can not
+                                                                     EA                                OA            EA                             OA                                                         be switched.
+                                                                        FA                             RA
+                                                                                                                                                    RA
+Version: MAY18
+                                                                                                                                              FA
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
+
+                                                                      FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 11
+SPECIFICATIONS & DIMENSIONS
+
+HLE 8XINH                                                           Energy Recovery Ventilator
+                                                                    Standard
+
+INDOOR UNIT                                                         SPECIFICATIONS
+
+                                        LE8XINV shown               Ventilation Type:                                                              Options:
+Download specification at:                                          Static plate, heat and humidity transfer                                       Spring vibration isolators
+renewaire.com/specifications                                                                                                                       Onboard variable frequency drives (VFDs) -
+                                                                    Typical Airflow Range: 2,000-8,800 CFM
+AIRFLOW PERFORMANCE                                                                                                                                   one or both airstreams
+                                                                    AHRI 1060 Certified Core: Eight L125-G5                                         Shaft grounding ring on motors with VFDs
+                                                                                                                                                   Fused disconnect
+                                                                    Standard Features:                                                             Integrated programmable controls -
+                                                                    TEFC Premium efficiency motors
+                                                                    Motor starters                                                                    enhanced, premium
+                                                                    Non-fused disconnect                                                           Class 1 low leakage motorized isolation dampers -
+                                                                    24 VAC transformer/relay package
+                                                                    Cross-core differential pressure ports                                            OA, RA or both airstreams
+                                                                                                                                                   Qty. 2, Factory mounted filter alarms -
+                                                                    Filters: Total qty. 16, MERV 8: 20" x 25" x 2"
+                                                                                                                                                      both airstreams
+                                                                    Unit Dimensions:                                                               Double wall construction
+                                                                    80 1/2" L x 165" W x 71 1/4" H                                                 Exterior paint - white, custom colors
+                                                                    Modular (per module) 1,214-1,672 lbs., varies by option(s)
+                                                                    Assembled (1-piece) 2,479-3,279 lbs., varies by option(s)                      Accessories:
+                                                                                                                                                   Filters - MERV 13, 2" or 4"; MERV 8, 4" (shipped loose)
+                                                                    Max. Shipping Dimensions & Weight (on pallet):                                 Digital time clock - wall mount (TC7D-W),
+                                                                    Modular (2-modules) 100" L x 90" W x 78" H
+                                                                                                                                                      in exterior enclosure (TC7D-E)
+                                                                       Module 1 - 1,852 lbs., Module 2 - 1,789 lbs.                                Carbon dioxide sensor/control -
+                                                                    Assembled (1-piece) 200" L x 90" W x 78" H -
+                                                                                                                                                      wall mount (CO2-W), duct mount (CO2-D)
+                                                                       3,638 lbs.                                                                  IAQ sensor - wall mount (IAQ-W),
+
+                                                                    Motor(s):                                                                         duct mount (IAQ-D)
+                                                                    Qty. 2, Belt drive blower/standard motor packages                              Motion occupancy sensor/control -
+
+                                                                       with choice of adjustable sheaves for low,                                     ceiling mount (MC-C), wall mount (MC-W)
+                                                                       medium or high blower speed (see table below)                               Smoke Detector - duct mount (SD-D)
+                                                                                                                                                   Electric duct heater - EK series (1–175 kW)
+                                                                                                                                                   Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                      (50-400 MBH), installed downstream of any fans
+
+                                                                                       External Static Pressure (in.w.g.)
+
+Airflow                0.00             0.25                  0.50                      0.75             1.00          1.25                         1.50        1.75        2.00
+ CFM
+                 BHP RPM BHP RPM BHP RPM                                BHP RPM BHP RPM                           BHP RPM                     BHP RPM BHP RPM BHP RPM
+                                                                                                                   3 HP MED
+                                                                                       3 HP LOW SPEED                SPEED                               3 HP HIGH SPEED
+
+2000                                                                    1.0 680 1.3 790 1.5 870 1.8 940 2.0 1000 2.2 1060
+
+3000                                                    1.1 640 1.4 740 1.7 820 2.0 890 2.3 960 2.6 1020 2.9 1070
+
+4000                                                    1.6 710 1.9 790 2.2 860 2.6 920 2.9 990 3.2 1040 3.6 1100                                                                                          5 HP
+                                                                                                                                                                                                          HIGH
+4500                             1.5 660 1.8 740 2.2 810 2.5 880 2.9 940 3.2 1000 3.6 1060 4.0 1110                                                                                                       SPEED
+
+5000                             1.7 690 2.1 770 2.5 840 2.8 900 3.2 960 3.6 1020 4.0 1070 4.5 1130                                                                                                       7.5 HP
+
+5500             1.7 650 2.0 730 2.4 8T0h0erma2l.8Perfo8r6m0ance3.R2ating9s3G0 5 2031.65.2.xl9s8x0 4.0 1040 4.5 8 1C0o9r0es (IO4.M9 ) 1140                                                                7.5 HP
+                                                                                                                                                                                                           HIGH
+6000             1.9 690 2.3 760 2.7 830 3.1 890 3.6 950 4.0 1010 4.5 1060 5.0 1110 5.5 1160                                                                                                              SPEED
+
+6250     3 HP    2.1 710 2.5 780 2.9 840 3.3 910 3.8 960 4.3 1020 4.7 1070 5.2 1120 5.7 1170
+         LOW
+6500    SPEED    2.3        720  2.7         790        3.1        860  3.6 920 4.0 980 4.5 1030 5.0 1080 5.5 1130 6.0 1180
+6750             2.4        740  2.9         810        3.3        870  3.8 930 4.3 990 4.8 1040 5.3 1100 5.8 1140 6.3 1190
+
+7000             2.6 760 3.1 830 3.5 890 4.0 950 4.5 1000 5.0 1060 5.6 1110 6.1 1160 6.6 1200
+
+7250             2.8 780 3.3 850 3.7 910 4.3 960 4.8 1020 5.3 1070 5.8 1120 6.4 1170 7.0 1210
+
+7500             3.0 800 3.5 860 4.0 920 4.5 980 5.0 1030 5.6 1080 6.2 1130 6.7 1180 7.3 1220
+
+7750             3.2 820 3.7 880 4.2 940 4.8 990 5.3 1050 5.9 1100 6.5 1140 7.1 1190
+
+8000             3.5 840 4.0 900 4.5 960 5.1 1010 5.6 1060 6.2 1110 6.8 1160 7.4 1200
+
+8250 5 HP 3.7 860 4.2 920 4.8 970 5.4 1030 5.9 1080 6.5 1120 7.1 1170
+
+8500 LOW 4.0 880 4.5 930 5.1 990 5.7 1040 6.3 1090 6.9 1140 7.5 1180
+
+8800 SPEED 4.3 900 4.9 960 5.5 1010 6.1 1060 6.7 1110 7.3 1150
+
+                                 5 HP MED               7.5 HP LOW                           7.5 HP MED SPEED
+                                  SPEED                   SPEED
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.                                      CORE PERFORMANCE
+ELECTRICAL DATA
+
+             Standard Electrical Specifications                           Optional Factory Installed                                                      Airflow (CFM)
+                                                                        VFD Electrical Specifications
+
+HP    Volts  HZ  Phase         FLA     Min. Cir.            Max.           FLA               Min. Cir.      Max.                                   2000  4000        6000        8000
+                            per motor   Amps            Overcurrent     per motor             Amps      Overcurrent                           90%
+                                                        Protection                                      Protection         Effectiveness (%)
+
+                                                           Device                                          Device
+
+3.0 208-230 60 Single 14.7-14 33.1                           40         9.38-8.48 40.2                        45                              70%
+
+    208-230 60 Three 9.38-8.48 21.1                          25         9.38-8.48 23.2                        25
+                                                             15
+3.0 460 60 Three 4.24                        9.5             15         4.24                 10.5             15                              50%
+
+      575 60 Three 3.3                       7.4             45         3.3                  8.2              15
+                                                             20
+    208-230 60 Three 14.5-13.4 32.6                          15         14.5-13.4 35.9                        45                              30%
+                                                                                                                                                       At AHRI 1060 standard conditions.
+5.0 460 60 Three 6.7                         15.1            60         6.7                  16.6             20                                       See all AHRI certified ratings at www.ahrinet.org.
+                                                             25
+      575 60 Three 5.3                       11.9            20         5.3                  13.1             15
+
+    208-230 60 Three 21.0-19.0 47.3                                     21.0-19.0 52.0                        60
+
+7.5 460 60 Three 9.5                         21.4                       9.5                  23.5             25
+
+      575 60 Three 7.6                       17.1                       7.6                  18.8             20
+
+Specifications may be subject to change without notice.
+
+12 RENEWAIRE.COM 1.800.627.4499
+                                                                      LE8XINH Energy Recovery Ventilator Standard                                                                                                                                               ABBREVIATIONS
+                                                                                                                                                                                                                                                                EA: Exhaust Air to outside
+                                                                                                                                                                                                    69 3/4"                                                     OA: Outside Air intake
+                                                                                                                                                                                                 Minimum                                                        RA: Room Air to be exhausted
+                                                                                                                                                                                           Service Area                                                         FA: Fresh Air to inside
+                                                                                                                                                                                                                                                                INSTALLATION ORIENTATION
+                                                                                                                                                                                                                 Door Door                                      Unit must be installed in orientation
+                                                                                                                                                                                                                 Swing Swing                                    shown.
+                                                                                                                                                                                                                                                                NOTE
+                                                                                                                                                                         EA                                                   OA                                1.UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                                DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                         FA                                                   RA                                NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                                2.SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                                TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                                                                                3.MIN. DUCT CLEARANCE FROM
+                                                                                                                                                                                                                                                                DAMPER BLADES WHEN FULLY
+                                                                                                                                                                                                                                                                OPENED TO BE 2". SMACNA RULES
+                                                                                                                                                                                                                                                                APPLY.
+
+                                                                                                                                                              36" E-Box          Door Door
+                                                                                                                                                              Minimum            Swing Swing
+                                                                                                                                                         Service Area
+
+                                                                                                                                                                        111" Minimum                                          78 1/2"
+                                                                                                                                                                        Service Area                                             Minimum
+
+                                                                                                                                                                        TOP VIEW                                                     Blower
+                                                                                                                                                                                                                                        Service
+                                                                                                                                                                             80 3/8" Overall                                                Area Typ.
+                                                                                                                                                                                 5" Damper
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 13            48" X 24"   13 3/8" X 15 1/2"                           E-Box                                                                                                          RA Inlet                                OA Inlet
+                                                                      Duct Receiving        Electrical                                                                          Frames Typ.                                                            48" X 24"                               48" X 24"
+                                                                                            Connection                                 Disconnect                                                                                                      Duct Receiving                          Duct Receiving
+                                                                           Flange Typ.      Cover                                      Switch              EA                                                                                          Flange                                  Flange
+
+                                                                                                      64 5/8"                                                                                                                    Pressure                                    164 7/8" Overall         OA Damper
+                                                                                                                                                                                                                                 Ports (4) Typ.                                                       Location
+                                                                                                  27 3/4"                                                                                                                                                                     161 3/8" Case           (Optional)
+                                                                                                                                                                                                                              OA
+                                                                      71 1/8" Overall
+                                                                           69 5/8" Case                                                         53 1/2"                      4"                                                                        8 7/8"                                  41 5/8"
+                                                                                   41 1/8"                                                                                                                                                                Typ.
+
+                                                                                                                                                           FA                                                                 RA
+
+                                                                      27 3/4"                 CL 11 3/8"                               29 5/8"                      2"           69 1/4" Case                                   2" Typ.                                 RA Damper              27 3/8"
+                                                                                            (5) 1 1/8                                                      CL 2 1/4"                CL 73 3/8"                                                                          Location
+                                                                                             Knockouts                                          CL 5 1/4"                            Lift Lugs                                                         27 3/8"          (Optional)
+                                                                                                                                                (2) 7/8"     Wiring
+                                                                                                                                                Knockouts                    FRONT VIEW                                                                         RIGHT VIEW
+                                                                                            LEFT VIEW
+
+                                                                      MAoIdReFLl:OLW E8CXOINNHFIGURATION                                                                                                                                                        UNIT MOUNTING & APPLICATION
+                                                                      DrAavawilabinlegas Tshyopwnein: dUimneintsiDonidmraweinngs. ion
+                                                                      Version: MAY18                                                                                                                                                                            Must be mounted as shown. RA/EA airstream can
+                                                                                                                                                                                                                                                                be switched with OA/FA airstream unless certain
+                                                                                                                                                                                                                                                                options are selected.
+
+                                                                                                                                                                                 LE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HLE 8XINV                                                           Energy Recovery Ventilator
+                                                                    Standard
+
+INDOOR UNIT                                                         SPECIFICATIONS
+
+Download specification at:                                          Ventilation Type:                                                              Options:
+renewaire.com/specifications                                        Static plate, heat and humidity transfer                                       Spring vibration isolators
+                                                                                                                                                   Onboard variable frequency drives (VFDs) -
+AIRFLOW PERFORMANCE                                                 Typical Airflow Range: 2,000-8,800 CFM
+                                                                                                                                                      one or both airstreams
+                                                                    AHRI 1060 Certified Core: Eight L125-G5
+                                                                                                                                                   Shaft grounding ring on motors with VFDs
+                                                                    Standard Features:                                                             Fused disconnect
+                                                                    TEFC Premium efficiency motors                                                  Integrated programmable controls -
+                                                                    Motor starters
+                                                                    Non-fused disconnect                                                              enhanced, premium
+                                                                    24 VAC transformer/relay package                                               Class 1 low leakage motorized isolation dampers -
+                                                                    Cross-core differential pressure ports
+                                                                                                                                                      OA, RA or both airstreams
+                                                                    Filters: Total qty. 16, MERV 8: 20" x 25" x 2"                                 Qty. 2, Factory mounted filter alarms -
+
+                                                                    Unit Dimensions & Weight:                                                         both airstreams
+                                                                    81 1/2" L x 165" W x 71 1/4" H                                                 Double wall construction
+                                                                    Modular (per module) 918-1,984 lbs., varies by option(s)                       Exterior paint - white, custom colors
+                                                                    Assembled (1-piece) 2,495-3,295 lbs., varies by option(s)
+                                                                                                                                                   Accessories:
+                                                                    Max. Shipping Dimensions & Weight (on pallet):                                 Filters - MERV 13, 2" or 4"; MERV 8, 4" (shipped loose)
+                                                                    Modular (2-modules) 100" L x 90" W x 78" H                                     Digital time clock - wall mount (TC7D-W),
+
+                                                                       Module 1 - 2,164 lbs., Module 2 - 1,493 lbs.                                   in exterior enclosure (TC7D-E)
+                                                                    Assembled (1-piece) 200" L x 90" W x 78" H -                                   Carbon dioxide sensor/control -
+
+                                                                       3,654 lbs.                                                                     wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                                   IAQ sensor - wall mount (IAQ-W),
+                                                                    Motor(s):
+                                                                    Qty. 2, Belt drive blower/standard motor packages                                 duct mount (IAQ-D)
+                                                                                                                                                   Motion occupancy sensor/control -
+                                                                       with choice of adjustable sheaves for low,
+                                                                       medium or high blower speed (see table below)                                  ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                                   Smoke Detector - duct mount (SD-D)
+                                                                                                                                                   Electric duct heater - EK series (1–175 kW)
+                                                                                                                                                   Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                      (50-400 MBH), installed downstream of any fans
+
+                                                                                       External Static Pressure (in.w.g.)
+
+Airflow                0.00             0.25                  0.50                      0.75             1.00         1.25                          1.50        1.75        2.00
+ CFM
+                 BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM
+
+                                                                                       3 HP LOW SPEED             3 HP MED                               3 HP HIGH SPEED
+                                                                                                                   SPEED
+
+2000                                                                    1.0 680 1.3 790 1.5 870 1.8 940 2.0 1000 2.2 1060
+
+3000                                                    1.1 640 1.4 740 1.7 820 2.0 890 2.3 960 2.6 1020 2.9 1070
+
+4000                                                    1.6 710 1.9 790 2.2 860 2.6 920 2.9 990 3.2 1040 3.6 1100                                                                                          5 HP
+                                                                                                                                                                                                          HIGH
+4500                             1.5 660 1.8 740 2.2 810 2.5 880 2.9 940 3.2 1000 3.6 1060 4.0 1110                                                                                                       SPEED
+
+5000                             1.7 690 2.1 770 2.5 840 2.8 900 3.2 960 3.6 1020 4.0 1070 4.5 1130                                                                                                       7.5 HP
+
+5500             1.7 650 2.0 730 2.4 8T0h0erma2l.8Perfo8r6m0ance3.R2ating9s3G0 5 2031.65.2.xl9s8x0 4.0 1040 4.5 8 1C0o9r0es (IO4.M9 ) 1140                                                                7.5 HP
+                                                                                                                                                                                                           HIGH
+6000             1.9 690 2.3 760 2.7 830 3.1 890 3.6 950 4.0 1010 4.5 1060 5.0 1110 5.5 1160                                                                                                              SPEED
+
+6250     3 HP    2.1 710 2.5 780 2.9 840 3.3 910 3.8 960 4.3 1020 4.7 1070 5.2 1120 5.7 1170
+         LOW
+6500    SPEED    2.3        720  2.7         790        3.1        860  3.6 920 4.0 980 4.5 1030 5.0 1080 5.5 1130 6.0 1180
+6750             2.4        740  2.9         810        3.3        870  3.8 930 4.3 990 4.8 1040 5.3 1100 5.8 1140 6.3 1190
+
+7000             2.6 760 3.1 830 3.5 890 4.0 950 4.5 1000 5.0 1060 5.6 1110 6.1 1160 6.6 1200
+
+7250             2.8 780 3.3 850 3.7 910 4.3 960 4.8 1020 5.3 1070 5.8 1120 6.4 1170 7.0 1210
+
+7500             3.0 800 3.5 860 4.0 920 4.5 980 5.0 1030 5.6 1080 6.2 1130 6.7 1180 7.3 1220
+
+7750             3.2 820 3.7 880 4.2 940 4.8 990 5.3 1050 5.9 1100 6.5 1140 7.1 1190
+
+8000             3.5 840 4.0 900 4.5 960 5.1 1010 5.6 1060 6.2 1110 6.8 1160 7.4 1200
+
+8250 5 HP 3.7 860 4.2 920 4.8 970 5.4 1030 5.9 1080 6.5 1120 7.1 1170
+
+8500 LOW 4.0 880 4.5 930 5.1 990 5.7 1040 6.3 1090 6.9 1140 7.5 1180
+8800 SPEED 4.3 900 4.9 960 5.5 1010 6.1 1060 6.7 1110 7.3 1150
+
+                                 5 HP MED               7.5 HP LOW                           7.5 HP MED SPEED
+                                  SPEED                   SPEED
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                            CORE PERFORMANCE
+
+             Standard Electrical Specifications                           Optional Factory Installed                                                      Airflow (CFM)
+                                                                        VFD Electrical Specifications
+
+HP    Volts  HZ  Phase         FLA     Min. Cir.            Max.           FLA               Min. Cir.      Max.                                   2000  4000        6000        8000
+                            per motor   Amps            Overcurrent     per motor             Amps      Overcurrent                           90%
+                                                        Protection                                      Protection         Effectiveness (%)
+
+                                                           Device                                          Device
+
+3.0 208-230 60 Single 14.7-14 33.1                           40         9.38-8.48 40.2                        45                              70%
+
+    208-230 60 Three 9.38-8.48 21.1                          25         9.38-8.48 23.2                        25
+                                                             15
+3.0 460 60 Three 4.24                        9.5             15         4.24                 10.5             15                              50%
+
+      575 60 Three 3.3                       7.4             45         3.3                  8.2              15
+                                                             20
+    208-230 60 Three 14.5-13.4 32.6                          15         14.5-13.4 35.9                        45                              30%
+                                                                                                                                                       At AHRI 1060 standard conditions.
+5.0 460 60 Three 6.7                         15.1            60         6.7                  16.6             20                                       See all AHRI certified ratings at www.ahrinet.org.
+                                                             25
+      575 60 Three 5.3                       11.9            20         5.3                  13.1             15
+
+    208-230 60 Three 21.0-19.0 47.3                                     21.0-19.0 52.0                        60
+
+7.5 460 60 Three 9.5                         21.4                       9.5                  23.5             25
+
+      575 60 Three 7.6                       17.1                       7.6                  18.8             20
+
+Specifications may be subject to change without notice.
+
+14 RENEWAIRE.COM 1.800.627.4499
+                                                                      LE8XINV Energy Recovery Ventilator Standard                                                                                                                                              ABBREVIATIONS
+                                                                                                                                                                                                                                                               EA: Exhaust Air to outside
+                                                                                                                                                                    69 3/4" Minimum                                                                            OA: Outside Air intake
+                                                                                                                                                                         Service Area                                                                          RA: Room Air to be exhausted
+                                                                                                                                                                                                                                                               FA: Fresh Air to inside
+                                                                                                                                                                                           Door Door                                                           INSTALLATION ORIENTATION
+                                                                                                                                                                                           Swing Swing                                                         Unit must be installed in orientation
+                                                                                                                                                                                                                                                               shown.
+                                                                                                                                                             RA                                             OA                   34"                           NOTE
+                                                                                                                                                                                                                                    Minimum                    1.UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                        Service Area           DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                               NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                             FA                                             EA                                                 2.SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                               TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                  36" E-Box                                                                                                    3.DUCT CLEARANCE FROM DAMPER
+                                                                                                                                                  Minimum                                                                                                      BLADES WHEN FULLY OPENED TO BE
+                                                                                                                                             Service Area                                                                                                      2". SMACNA RULES
+                                                                                                                                                                                                                                                               APPLY.
+
+                                                                                                                                                                                           Door Door        78 1/2"
+                                                                                                                                                                                           Swing Swing         Minimum Blower
+
+                                                                                                                                                                                                                   Service Area
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 15              RA Inlet  13 3/8" X 15 1/2"                                                                          111" Minimum                                                              OA Damper              OA Inlet
+                                                                                48" X 24"   Electrical                                                                                 Service Area                                                              Location               48" X 24"
+                                                                      Duct Receiving        Connection                                                                                                                                                           (Optional)             Duct Receiving
+                                                                                            Cover                                                                                          TOP VIEW                                                                                     Flange
+                                                                                   Flange                                                                                                                                                                      164 7/8" Overall
+                                                                                                   64 5/8"                                                                                 81 1/2" Overall                                                      161 3/8" Case
+                                                                      26 1/4"
+                                                                                               27 3/4"                      E-Box               5" Damper
+                                                                                                                                               Frames Typ.                                                    Pressure
+                                                                      71 1/8" Overall                                      Disconnect                                                                         Ports (4) Typ.
+                                                                          69 5/8" Case                                     Switch                 RA
+                                                                                                                                                                                                            OA
+
+                                                                                                                                    53 1/2"                                            4"                   EA                                        9"                                41 3/4"
+                                                                                                                                                                                                                                                         Typ.                              Typ.
+                                                                                                                                                                                                              2" Typ.
+                                                                                                                                                             FA                                             2" Duct
+                                                                                                                                                                                                            Flange Typ.
+                                                                      RA Damper                               CL 11 3/8"   29 5/8"  CL 5 1/4"  CL 2 1/4"                                  69 1/4" Case                                                27 5/8"           48" X 24"       26 1/4"
+                                                                      Location                             (5) 1 1/8                (2) 7/8"     Wiring                                                                                                                 Duct Receiving
+                                                                      (Optional)                            Knockouts               Knockouts                                                CL 73 3/8"                                                                 Flange Typ.
+                                                                                                                                                                                              Lift Lugs
+                                                                                            LEFT VIEW                                                                                                                                                          RIGHT VIEW
+                                                                                                                                                                                       FRONT VIEW
+
+                                                                          AIRFLOW CONFIGURATION                                                                                                                                                                UNIT MOUNTING & APPLICATION
+
+                                                                      MoAdvaeilalb:leLaEs8shXowINn Vin dimension drawing.                                                                                                                                      Must be mounted as shown. RA/EA airstream can
+                                                                      Drawing Type: Unit Dimension                                                                                                                                                             be switched with OA/FA airstream unless certain
+                                                                      Version: MAY18                                                                                                                                                                           options are selected.
+
+                                                                                                                                                                                           LE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HLE 8XRT                                                               Energy Recovery Ventilator
+                                                                       Standard
+
+ROOFTOP UNIT                                                           SPECIFICATIONS
+
+                                                                       Ventilation Type:                                                           Options:
+                                                                       Static plate, heat and humidity transfer                                    Spring vibration isolators
+                                                                                                                                                   Onboard variable frequency drives (VFDs) -
+                                                                       Typical Airflow Range: 2,000-8,800 CFM
+                                                                                                                                                      one or both airstreams
+                                                                       AHRI 1060 Certified Core: Eight L125-G5                                      Shaft grounding ring on motors with VFDs
+                                                                                                                                                   Fused disconnect
+                                                                       Standard Features:                                                          Integrated programmable controls -
+                                                                       TEFC Premium efficiency motors
+                                                                       Motor starters                                                                 enhanced, premium
+                                                                       Non-fused disconnect                                                        Class 1 low leakage motorized isolation dampers -
+                                                                       24 VAC transformer/relay package
+                                                                       Cross-core differential pressure ports                                         OA, RA or both airstreams
+                                                                                                                                                   Qty. 2, Factory mounted filter alarms -
+                                                                       Filters: Total qty. 16, MERV 8: 20" x 25" x 2"
+                                                                                                                                                      both airstreams
+                                                                                                                                                   Double wall construction
+                                                                                                                                                   Exterior paint - white, custom colors
+
+                                           LE10XRT shown               Unit Dimensions & Weight:                                                   Accessories:
+Download specification at:                                             111 1/4" L x 165 1/2" W x 71 1/4" H                                         Filters - MERV 13, 2" or 4"; MERV 8, 4" (shipped loose)
+renewaire.com/specifications                                           Modular (per module) 1,311-1,806 lbs., varies by option(s)                  Roof Curb - Standard 14"
+                                                                       Assembled (1-piece) 2,631-3,453 lbs., varies by option(s)                   Curb wind clip
+AIRFLOW PERFORMANCE                                                                                                                                Engineered combo curb for Carrier RTU
+                                                                       Max. Shipping Dimensions & Weight (on pallet):                              Engineered combo curb for Trane RTU
+                                                                       Modular (2-modules) 100" L x 90" W x 78" H                                  Digital time clock - wall mount (TC7D-W),
+
+                                                                          Module 1 - 1,986 lbs., Module 2 - 1,917 lbs.                                in exterior enclosure (TC7D-E)
+                                                                       Assembled (1-piece) 200" L x 90" W x 78" H -                                Carbon dioxide sensor/control -
+
+                                                                          3,812 lbs.                                                                  wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                                   IAQ sensor - wall mount (IAQ-W), duct mount (IAQ-D)
+                                                                       Motor(s):                                                                   Motion occupancy sensor/control -
+                                                                       Qty. 2, Belt drive blower/standard motor packages
+                                                                                                                                                      ceiling mount (MC-C), wall mount (MC-W)
+                                                                          with choice of adjustable sheaves for low,                               Smoke Detector - duct mount (SD-D)
+                                                                          medium or high blower speed (see table below)                            Electric duct heater - EK series (1–175 kW);
+
+                                                                                                                                                      designed for indoor ductwork installation only
+                                                                                                                                                   Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                      (50-400 MBH), installed downstream of any fans
+
+Airflow                                                                                 External Static Pressure (in.w.g.)
+ CFM
+                     0.00        0.25                       0.50       0.75                       1.00               1.25                         1.50       1.75             2.00
+                 BHP RPM     BHP RPM                    BHP RPM                                                                               BHP RPM    BHP RPM          BHP RPM
+                                                                       BHP RPM BHP RPM BHP RPM
+
+                                                                                       3 HP LOW SPEED         3 HP MED                                   3 HP HIGH SPEED
+                                                                                                               SPEED
+
+2000                                                      1.3 640 1.3 730 1.4 810 1.6 8 90 1.9 960 2.4 1030 2.9 1100
+
+3000                                                      1.5 700 1.6 780 1.9 860 2.2 930 2.7 1000 3.1 1060 3.7 1130 5 HP HIGH
+
+4000                             1.6 680 1.9 760 2.2 840 2.6 910 3.0 980 3.5 1040 4.0 1100 4.6 1160 SPEED
+
+4500                             1.8 710 2.1 800 2.5 870 3.0 940 3.5 1010 4.0 1060 4.5 1120 5.1 1170
+
+5000               1.7  660      2.1  750                 2.5  83T0herm3.a0l Per9fo10rman3c.e5 Rati9n7g0s G5 42.015.21.0x3ls0x 4.5 1090 5.1 1184C0ores5.(6IOM1)190                                       7.5 HP
+5500                    710      2.4  790                 2.9  870 3.4 940 4.0 1000 4.5 1060 5.1 1110 5.6 1160 6.2 1210                                                                                  HIGH
+6000     3 HP 2.0       750      2.9  840                 3.4  910 4.0 970 4.5 1030 5.1 1090 5.7 1140 6.2 1190 6.8 1230                                                                                  SPEED
+6250     LOW 2.4        780      3.1  860                 3.7  930 4.2 990 4.8 1050 5.4 1100 6.0 1150 6.5 1200 7.1 1240
+        SPEED 2.6
+
+6500             2.8 800 3.4 880 4.0 950 4.5 1010 5.1 1060 5.7 1110 6.3 1160 6.8 1210 7.4 1250
+
+6750     5 HP    3.1 820 3.7 900 4.3 960 4.8 1020 5.4 1080 6.0 1130 6.6 1180 7.2 1220
+         LOW
+7000    SPEED    3.3    850      4.0  920                 4.6 980 5.2 1040 5.8 1090 6.3 1140 6.9 1190 7.5 1230
+7250             3.6    870      4.3  940                 4.9 1000 5.5 1060 6.1 1110 6.7 1160 7.2 1200
+
+7500             3.9 900 4.6 960 5.2 1020 5.8 1080 6.4 1120 7.0 1170
+
+7750 5 HP 4.3 920 4.9 980 5.6 1040 6.2 1090 6.8 1140 7.4 1180
+8000 MED 4.6 940 5.3 1000 5.9 1060 6.5 1110 7.1 1160
+8250 SPEED 5.0 970 5.7 1020 6.3 1080 6.9 1130 7.5 1170
+
+8500             5.4 990 6.0 1050 6.7 1100 7.3 1140
+
+8800             5.9 1020 6.5 1070 7.1 1120
+
+      7.5 HP LOW SPEED                7.5 HP MED SPEED
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.                                      CORE PERFORMANCE
+ELECTRICAL DATA
+
+             Standard Electrical Specifications                                          Optional Factory Installed
+                                                                                       VFD Electrical Specifications
+                                                                                                                                                         Airflow (CFM)
+                                                               Max.                                     Max.
+
+HP    Volts  HZ  Phase     FLA Min. Cir.                  Overcurrent     FLA Min. Cir.                 Overcurrent                                2000  4000             6000      8000
+                        per motor Amps                    Protection   per motor Amps                   Protection                            90%
+                                                                                                                           Effectiveness (%)
+                                                               Device                                   Device
+
+3.0 208-230 60 Single 14.7-14 33.1                             40      9.38-8.48 40.2                   45                                    70%
+
+    208-230 60 Three 9.38-8.48 21.1                            25      9.38-8.48 23.2                   25
+
+3.0 460 60 Three 4.24                 9.5                      15      4.24                 10.5        15                                    50%
+
+      575 60 Three           3.3      7.4                      15                      3.3  8.2         15
+
+    208-230 60 Three 14.5-13.4 32.6                            45      14.5-13.4 35.9                   45                                    30%
+                                                                                                                                                      At AHRI 1060 standard conditions.
+5.0 460 60 Three             6.7      15.1                     20                      6.7  16.6        20                                            See all AHRI certified ratings at www.ahrinet.org.
+
+      575 60 Three           5.3      11.9                     15                      5.3  13.1        15
+
+    208-230 60 Three 21.0-19.0 47.3                            60      21.0-19.0 52.0                   60
+
+7.5 460 60 Three             9.5      21.4                     25                      9.5  23.5        25
+
+      575 60 Three           7.6      17.1                     20                      7.6  18.8        20
+
+Specifications may be subject to change without notice.
+
+16 RENEWAIRE.COM 1.800.627.4499
+                                                                      LE8XRT (RTV/RTR) Energy Recovery Ventilator Standard
+
+                                                                                                               CURB LE8X                                                            69 3/4" Minimum                                                    RA Damper              ABBREVIATIONS
+                                                                                                                                                                                         Service Area                                                  Location               EA: Exhaust Air to outside
+                                                                                                                                                                                                                                                       (Optional)             OA: Outside Air intake
+                                                                                                               64 1/4" O.D.                                              FA (RTV)                                                    Door Door                                RA: Room Air to be exhausted
+                                                                                                                                                                         (2) 16 1/8" X 16 3/8"                                       Swing Swing                              FA: Fresh Air to inside
+                                                                                                                                                                         Openings                                                                                             RTV: Rooftop Vertical RA & FA
+                                                                                                A                            A                                                                                                                                                RTR: Rooftop Vertical RA Only
+                                                                                                                                                                                                                                                                              INSTALLATION ORIENTATION
+                                                                                                155 1/4" O.D.                9 1/2"          151 1/2" I.D.                           EA                                                      18 1/4"               OA         Unit must be installed in orientation
+                                                                                                     49"                                                                                                                                                                      shown.
+                                                                                                20"                          25"                                           36" E-Box                                                   49 3/8"                RA              NOTE:
+                                                                                                                                                                           Minimum                                                   Door Door                24" X 48"       1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                               FA RA                                                     Service Area                                                Swing Swing              Opening         DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                                              NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                        65 1/4"                                                        52 1/8"     OA         2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                                              TO CHANGE WITHOUT NOTICE.
+
+                                                                                                21 1/4"                                  3"                                                      38 1/4"                                               78 1/2"                CURB CROSS-SECTION A-A (TYP.)
+                                                                                                                 60 1/2" I.D.                                                                                                                             Minimum
+                                                                                                                                                                                                                                                              Blower Service  1 1/2" X 1/4"              1 7/8"
+                                                                                                               TOP VIEW                                                                                                                                          Area Typ.    Neoprene Gasket
+
+                                                                                                                                                                                                          111" Minimum                                                        3/4" X 3 1/2"                      14"
+                                                                                                                                                                                                          Service Area                                                        Wooden Nailer
+
+                                                                                                                                                                                                                                                                                                     3"
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 17                                           13 3/8" X 15 1/2"                                                                                                     TOP VIEW                                 SECTION A-A
+                                                                                                               Electrical
+                                                                      EA Outlet                                Connection                                           E-Box                                                            111 1/4" Overall                         165 3/8" Overall
+                                                                                                               Cover                                                                                                                   69 1/8" Case                            162 5/8" Case
+                                                                                                                                                                    Disconnect      22 1/2"                                                            19 3/4"
+                                                                                                                    64 5/8"                                         Switch
+
+                                                                      71 1/8" Overall                                                                               8 7/8"          FA            RTR                                                  Pressure Ports
+                                                                            65 5/8"                                                                                                              ONLY                                                  (4) Typ.
+                                                                                Case                                                                                     FA
+
+                                                                                       38 5/8"                                                                            53 1/2"
+
+                                                                                                25 1/4"                                        27 3/4"                          RA     2" Duct                                         73 3/8"         2" Typ.                                            OA Inlets,
+                                                                                                                                                                                                                                 RAFlange Typ.Lifting Lugs                                              OA Damper
+                                                                                                               CL 11 3/8"                       CL 5 1/4"
+                                                                      FA (RTR)                                 (5) 7/8"                         (2) 7/8"                                                                             FA                                                                   Locations
+                                                                                                                                                Knockouts                                                                                                                                                 (Optional)
+                                                                      48" X 24"                                Knockouts                                                                                                              RTV  RA
+                                                                                                                                             HERT except 6x 8x, LERT                                                                 ONLY                                     RIGHT VIEW
+                                                                      Duct Receiving
+                                                                                                                                                                                    FRONT VIEW HERT except 6x 8x, LERT                                                                       UNIT MOUNTING & APPLICATION
+                                                                      Flange                    LEFT VIEW                                                                                                                                                                                    Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                                                                                                                             be switched.
+                                                                      ModAeIRlF: LLOE8WXCROTNVF/IRGTURRATION                                                        RTV                          RTR
+                                                                      DrawAvaiinlabgle aTsysphoewn:: Unit Dimension
+                                                                      Version: MAY18                                                         EA                                 OA  EA                                               OA
+
+                                                                                                                                                                                        FA
+
+                                                                                                                                                                                                                                     LE-SERIES
+                                                                                                                                                                                                                                                                                                                                     SPECIFICATIONS & DIMENSIONS
+18 RENEWAIRE.COM 1.800.627.4499
+LE8XRT (RTH/RTF) Energy Recovery Ventilator Standard
+
+                                                                                                         69 3/4" Minimum                                                                    ABBREVIATIONS
+                                                                                                              Service Area                                                                  EA: Exhaust Air to outside
+                                                                                                                                                                                            OA: Outside Air intake
+                                         CURB LE8X                                                                                                                                          RA: Room Air to be exhausted
+                                                                                                                                                                                            FA: Fresh Air to inside
+                                         64 1/4" O.D.                                                FA (RTF)                  Door   Door                                                  RTF: Rooftop Vertical FA Only
+                                                                                                     (2) 16 1/8" X 16 3/8"     Swing  Swing                                                 RTH: Rooftop Horizontal RA & FA
+                                                                                                     Openings                                                                               INSTALLATION ORIENTATION
+                                                                                                                                                                                            Unit must be installed in orientation
+                          A                            A                                                                                                                                    shown.
+                                                                                                                                                                                            NOTE:
+                                                                                                        EA                                       OA                                         1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                            DIMENSIONS ARE ROUNDED TO THE
+                          155 1/4" O.D.                9 1/2"          151 1/2" I.D.         36" E-Box                                                                                      NEAREST EIGHTH OF AN INCH.
+                               49"                                                           Minimum                                                                                        2. SPECIFICATIONS MAY BE SUBJECT
+                          20"                          25"                                 Service Area                               18 1/4"                                               TO CHANGE WITHOUT NOTICE.
+
+                                         FA RA
+
+                                                                                                           65 1/4"                               OA
+
+                                                                                                                    FA                                                  CURB CROSS-SECTION A-A (TYP.)
+
+                          21 1/4"                                  3"                                                 38 1/4"  Door   Door       78 1/2"                                    1 1/2" X 1/4"              1 7/8"
+                                           60 1/2" I.D.                                                                        Swing  Swing         Minimum                                 Neoprene Gasket
+                                                                                                                                                        Blower Service
+                                         TOP VIEW                                                                                                          Area Typ.                        3/4" X 3 1/2"
+                                                                                                                                                                                            Wooden Nailer
+                                                                                                                                                                                                                               14"
+                                                                                                                                                                                                                   3"
+
+                                         13 3/8" X 15 1/2"                                                                   111" Minimum                                                   SECTION A-A
+                                         Electrical                                                                          Service Area
+                                         Connection
+                                         Cover                                                                                    TOP VIEW
+
+EA Outlet                                     64 5/8"                                 E-Box                                    111 1/4" Overall                         RA                  165 3/8" Overall
+                                                                                                                                  69 1/8" Case                          Damper               162 5/8" Case
+                                                                                      Disconnect         22 1/2"                                   19 3/4"              Location
+                                                                                      Switch                                                                            (Optional)
+71 1/8" Overall                                                                                                                                  Pressure Ports
+      65 5/8"                                                                         8 7/8"                                                     (4) Typ.                           8 7/8"
+          Case                                                                              53 1/2"
+                                                                                                         FA   RTH                                RA
+                 38 5/8"                                                                                     ONLY
+
+                          25 1/4"         CL 11 3/8"                      27 3/4"                           2" Duct              73 3/8"              2" Typ.                               27 3/8"                     OA Inlets,
+                                           (5) 7/8"                                                      Flange Typ.           Lifting Lugs                                                                            OA Damper
+                                         Knockouts                             CL 5 1/4"                                                         5" Damper                                  RIGHT VIEW
+FA (RTH)                                                                      (2) 7/8"                                         FA                Frames Typ.            RA                                              Locations
+48" X 24"                                                                     Knockouts                                                                                 48" X 24"                                       (Optional)
+                                                                                                                                RTF                                     Duct Receiving
+                                                                       HERT except 6x 8x, LERT                                 ONLY                                     Flange
+
+Duct Receiving            LEFT VIEW                                                                          FRONT VIEW HERTexcept 6x 8x, LERT
+Flange
+
+ModAeIRl:FLLOE8WXCROTNHF/IRGTUFRATION                                                 RTH                         RTF                                                                                                  UNIT MOUNTING & APPLICATION
+DrawAvaiinlabgle aTsysphoewn:: Unit Dimension
+                                                                       EA                            OA  EA                    OA                                                                                      Must be mounted as shown. Airstreams can not
+                                                                          FA                         RA                                                                                                                be switched.
+Version: MAY18                                                                                                                 RA
+T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
+
+                                                                      FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 19
+SPECIFICATIONS & DIMENSIONS
+
+HLE 10XINH Energy Recovery Ventilator
+                                                                 Standard
+
+INDOOR UNIT                                                       SPECIFICATIONS
+
+                                          LE10XINV shown          Ventilation Type:                                                           Options:
+Download specification at:                                        Static plate, heat and humidity transfer                                    Spring vibration isolators
+renewaire.com/specifications                                                                                                                  Onboard variable frequency drives (VFDs) -
+                                                                  Typical Airflow Range: 2,500-11,000 CFM
+AIRFLOW PERFORMANCE                                                                                                                              one or both airstreams
+                                                                  AHRI 1060 Certified Core: Ten L125-G5                                        Shaft grounding ring on motors with VFDs
+                                                                                                                                              Fused disconnect
+                                                                  Standard Features:                                                          Integrated programmable controls -
+                                                                  TEFC Premium efficiency motors
+                                                                  Motor starters                                                                 enhanced, premium
+                                                                  Non-fused disconnect                                                        Class 1 low leakage motorized isolation dampers -
+                                                                  24 VAC transformer/relay package
+                                                                  Rubber vibration isolators                                                     OA, RA or both
+                                                                  Cross-core differential pressure ports                                      Qty. 2, Factory mounted filter alarms -
+
+                                                                  Filters: Total qty. 20, MERV 8: 20" x 25" x 2"                                 both airstreams
+                                                                                                                                              Double wall construction
+                                                                  Unit Dimensions & Weight:                                                   Exterior paint - white, custom colors
+                                                                  80 1/2" L x 205 1/2" W x 71 1/4" H
+                                                                  Modular (per module) 1,423-1,912 lbs., varies by option(s)                  Accessories:
+                                                                  Assembled (1-piece) 2,858-3,799 lbs., varies by option(s)                   Filters - MERV 13, 2" or 4"; MERV 8, 4" (shipped loose)
+                                                                                                                                              Digital time clock - wall mount (TC7D-W),
+                                                                  Max. Shipping Dimensions & Weight (on pallet):
+                                                                  Modular (2-modules) 120" L x 90" W x 78" H                                     in exterior enclosure (TC7D-E)
+                                                                                                                                              Carbon dioxide sensor/control -
+                                                                     Module 1 - 2,132 lbs., Module 2 - 2,107 lbs.
+                                                                  Assembled (1-piece) 240" L x 90" W x 78" H - 4,239 lbs.                        wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                              IAQ sensor - wall mount (IAQ-W), duct mount (IAQ-D)
+                                                                  Motor(s):                                                                   Motion occupancy sensor/control -
+                                                                  Qty. 2, Belt drive blower/standard motor packages
+                                                                                                                                                 ceiling mount (MC-C), wall mount (MC-W)
+                                                                     with choice of adjustable sheaves for low,                               Smoke Detector - duct mount (SD-D)
+                                                                     medium or high blower speed. (see table below)                           Electric duct heater - EK series (1–175 kW)
+                                                                                                                                              Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                 (50-400 MBH), installed downstream of any fans
+
+Airflow                                                                                 External Static Pressure (in.w.g.)
+ CFM
+                    0.00        0.25                   0.50                 0.75                 1.00                1.25                          1.50            1.75             2.00
+                BHP RPM     BHP RPM                BHP RPM
+                                                                       BHP RPM BHP RPM BHP RPM                                                BHP RPM BHP RPM BHP RPM
+
+                                                                            3 HP LOW SPEED                  3 HP MED SPEED                                    3 HP HIGH SPEED
+
+2500                                                                   1.1 710 1.3 790 1.6                                 870                1.8 930 2.1 1000 2.4 1050
+
+3000                                               1.0 640 1.3 730 1.5 810 1.8                                             880                2.0 950 2.3 1010 2.6 1070
+
+3500                                               1.2 660 1.4 750 1.7 830 2.0                                             900                2.3 960 2.6 1020 2.9 1080
+
+4000                                               1.4 680 1.6 770 1.9 840 2.2                                             910                2.5 980 2.9 1040 3.2 1100
+
+4500                                               1.6 710 1.9 790 2.2 860 2.5                                             930                2.8 990 3.2 1050 3.5 1110 5 HP
+
+5000                        1.6 670 1.9 740 2.1 810 2.5 880 2.8                                                            940                3.1 1000 3.5 1060 3.9 1120 HIGH
+
+5500            1.6 640 1.9 710 2.2 770 2.5 840 2.8 900 3.1                                                                960                3.5 1020 3.8 1080 4.2 1130 SPEED
+
+6000 3 HP 2.0 690 2.2 750 2.5 810 2.8 870 3.1 920 3.5                                                                      980                3.9 1040 4.2 1090 4.6 1150
+
+         LOW                                                                                                                                                                               7.5 HP
+        SPEED
+6500            2.4  740    2.6  790               2.9    850          3.2             900  3.6        950      3.9        1000               4.3 1060 4.7 1110 5.1 1160 MED
+
+                                                               Thermal Performance Ratings G5 2015.2.xlsx                                                          10 Cores (IOM)          SPEED
+
+7000            2.8 790 3.1 830 3.4 880 3.7 930 4.0 980 4.4 1030                                                                              4.8 1080 5.2 1130 5.6 1170
+
+7500 5 HP 3.3 830 3.6 880 3.9 920 4.2 970 4.6 1010 4.9 1050                                                                                   5.3 1100 5.7 1140 6.1 1190
+
+8000     LOW    3.9  880    4.2  920               4.5    960          4.8 1000 5.1 1040                        5.5        1080               5.9       1120  6.3  1160        6.7  1200   7.5 HP
+        SPEED                                                                                                                                                                              HIGH
+
+        5 HP                                                                                                                                                                               SPEED
+
+8500 MED 4.5 930 4.8 960 5.1 1000 5.4 1030 5.8 1070 6.1 1100                                                                                  6.5 1140 6.9 1180 7.3 1210
+
+        SPEED
+
+9000 7.5 HP 5.2 970 5.5 1000 5.8 1030 6.1 1060 6.4 1100 6.8 1130                                                                              7.1 1160 7.5 1190 7.9 1220
+
+9500 LOW 5.9 1010 6.2 1040 6.5 1060 6.8 1090 7.1 1120 7.5 1150                                                                                7.8       1180  8.2  1210        8.5  1230   10 HP
+                                                                                                                                              8.5       1190  8.9  1220        9.2  1240   HIGH
+10000 SPEED 6.7 1040 7.0 1070 7.3 1090 7.6 1120 7.9 1140 8.2 1170
+
+        7.5 HP                                                                                                                                9.3 1210 9.6 1230 10.0 1250 SPEED
+
+10500 MED 7.5 1080 7.8 1100 8.1 1120 8.4 1140 8.7 1160 9.0 1190
+
+        SPEED
+
+11000           8.4 1100 8.6 1120 8.9 1140 9.2 1160 9.5 1180 9.8 1200
+
+                            10 HP MED SPEED                                                       10 HP HIGH SPEED
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                            CORE PERFORMANCE
+
+                Standard Electrical Specifications                            Optional Factory Installed                                                      Airflow (CFM)
+                                                                            VFD Electrical Specifications
+                                                                                                                                                         4000 6000 8000
+                                                          Max.                                              Max.
+
+HP      Volts   HZ   Phase     FLA Min. Cir.              Overcurrent     FLA Min. Cir.                Overcurrent                                2000                              10000 12000
+                            per motor Amps                Protection   per motor Amps                  Protection                             90%
+                                                                                                                           Effectiveness (%)
+                                                          Device                                            Device
+
+3.0 208-230 60 Single 14.7-14 33.1                        40           9.38-8.48 40.2                       45                   70%
+
+      208-230 60 Three 9.38-8.48 21.1                     25           9.38-8.48 23.2                       25                   50%
+
+3.0 460 60 Three 4.24            9.5                      15                4.24            10.5            15                   30%
+                                                                                                                                        At AHRI 1060 standard conditions.
+        575 60 Three        3.3  7.4                      15                3.3             8.2             15                          See all AHRI certified ratings at www.ahrinet.org.
+
+      208-230 60 Three 14.5-13.4 32.6                     45           14.5-13.4 35.9                       45             Specifications may be subject to change without notice.
+
+5.0 460 60 Three            6.7  15.1                     20                6.7             16.6            20
+
+        575 60 Three        5.3  11.9                     15                5.3             13.1            15
+
+      208-230 60 Three 21.0-19.0 47.3                     60           21.0-19.0 52.0                       60
+
+7.5 460 60 Three            9.5  21.4                     25                9.5             23.5            25
+
+        575 60 Three        7.6  17.1                     20                7.6             18.8            20
+
+      208-230 60 Three 27.0-24.4 60.8                     80           27.0-24.4 66.8                       80
+
+10.0 460 60 Three 12.2           27.5                     35                12.2            30.2            35
+
+        575 60 Three 9.76        22.0                     30                9.76            24.2            30
+
+20 RENEWAIRE.COM 1.800.627.4499
+                                                                      LE10XINH Energy Recovery Ventilator Standard
+
+                                                                                                                                                                                           69 3/4"                                                        ABBREVIATIONS
+                                                                                                                                                                                         Minimum                                                          EA: Exhaust Air to outside
+                                                                                                                                                                                       Service Area                                                       OA: Outside Air intake
+                                                                                                                                                                                                                                                          RA: Room Air to be exhausted
+                                                                                                                                                                                       Door   Door                                                        FA: Fresh Air to inside
+                                                                                                                                                                                       Swing  Swing                                                       INSTALLATION ORIENTATION
+                                                                                                                                                                                                                                                          Unit must be installed in orientation
+                                                                                                                                                                                   EA                          OA                                         shown.
+                                                                                                                                                                                                                                                          NOTE
+                                                                                                                                                                                                                                                          1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                                                                                                                          DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                          NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                          2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                                          TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                                                                                                                          3. MIN. DUCT CLEARANCE FROM
+                                                                                                                                                                                                                                                          DAMPER BLADES WHEN FULLY
+                                                                                                                                                                                                                                                          OPENED TO BE 2". SMACNA RULES
+                                                                                                                                                                                                                                                          APPLY.
+
+                                                                                                                                                                            FA                                 RA
+
+                                                                                                                                                         36" E-Box
+                                                                                                                                                         Minimum
+                                                                                                                                                    Service Area
+
+                                                                                                                                                                                       Door   Door             79 7/8"
+                                                                                                                                                                                       Swing  Swing               Minimum
+
+                                                                                                 13 3/8" X 15 1/2"                                                                                                    Blower            RA Inlet
+                                                                                                                                                                                                                         Service        48" X 24"
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 21                             Electrical                                                                              111" Minimum                        Area Typ.  Duct Receiving                            OA Inlet
+                                                                                                                                                                                          Service Area                                  Flange                                    48" X 24"
+                                                                      48" X 24"                  Connection                 E-Box                                                                                                                                                 Duct Receiving
+                                                                                                                    Disconnect                                                          TOP VIEW                                                                205 3/8" Overall  Flange
+                                                                      Duct Receiving             Cover                                                                                                                                                            202 5/8" Case
+                                                                                                                           Switch                                                                     80 3/8"
+                                                                      Flange Typ.                                                                                                                    Overall
+                                                                                                                     47 1/4"                                                          2"
+                                                                                                                        84 5/8"                     53 1/2"                                                    Pressure
+                                                                                                                                                                                   EA                          Ports (4) Typ.
+                                                                      71 1/8" Overall
+                                                                          69 5/8" Case                                                                                                                           OA
+
+                                                                                                           47 1/4"                                                                 FA                          RA                                                                             41 1/2"
+
+                                                                                                                                        CL 11 3/8"41 1/8"29 5/8"                           69 1/8" Case               2"                         47 1/4"      RA Damper              47 1/4"
+                                                                                                                                     (5) 1 1/8"                                4"              73 3/8"             Typ.                                       Location
+                                                                                                                                      Knockouts     CL 5 1/4"  CL 2 1/4"                      Lift Lugs                                 8 3/4"                (Optional)          OA Damper
+                                                                                                                                                    (2) 7/8"     Wiring                                        5" Damper                   Typ.                                   Location
+                                                                                                   LEFT VIEW                                        Knockouts                          FRONT VIEW              Frames Typ.                                RIGHT VIEW              (Optional)
+                                                                      AMIRoFdLOeW l: LCE1O0NXFINIGHURATION
+                                                                      ADvairlaabwle ains sghowTyn pin edim: eUnsnioint dDraiwminge. nsion                                                                                                                 UNIT MOUNTING & APPLICATION
+                                                                      Version: MAY18
+                                                                                                                                                                                                                                                          Must be mounted as shown. RA/EA airstream can
+                                                                                                                                                                                                                                                          be switched with OA/FA airstream unless certain
+                                                                                                                                                                                                                                                          options are selected.
+
+                                                                                                                                                                                   LE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HLE 10XINV                                                   Energy Recovery Ventilator
+                                                             Standard
+
+INDOOR UNIT                                                  SPECIFICATIONS
+
+Download specification at:                                   Ventilation Type:                                                                     Options:
+renewaire.com/specifications                                 Static plate, heat and humidity transfer                                              Spring vibration isolators
+                                                                                                                                                   Onboard variable frequency drives (VFDs) -
+AIRFLOW PERFORMANCE                                          Typical Airflow Range: 2,500-11,000 CFM
+                                                                                                                                                      one or both airstreams
+                                                             AHRI 1060 Certified Core: Ten L125-G5                                                  Shaft grounding ring on motors with VFDs
+                                                                                                                                                   Fused disconnect
+                                                             Standard Features:                                                                    Integrated programmable controls -
+                                                             TEFC Premium efficiency motors
+                                                             Motor starters                                                                           enhanced, premium
+                                                             Non-fused disconnect                                                                  Class 1 low leakage motorized isolation dampers -
+                                                             24 VAC transformer/relay package
+                                                             Rubber vibration isolators                                                               OA, RA or both
+                                                             Cross-core differential pressure ports                                                Qty. 2, Factory mounted filter alarms -
+
+                                                             Filters: Total qty. 20, MERV 8: 20" x 25" x 2"                                           both airstreams
+                                                                                                                                                   Double wall construction
+                                                             Unit Dimensions & Weight:                                                             Exterior paint - white, custom colors
+                                                             81 1/2" L x 205 1/2" W x 71 1/4" H
+                                                             Modular (per module) 1,127-2,222 lbs., varies by option(s)                            Accessories:
+                                                             Assembled (1-piece) 2,858-3,788 lbs., varies by option(s)                             Filters - MERV 13, 2" or 4"; MERV 8, 4" (shipped loose)
+                                                                                                                                                   Digital time clock - wall mount (TC7D-W),
+                                                             Max. Shipping Dimensions & Weight (on pallet):
+                                                             Modular (2-modules) 120" L x 90" W x 78" H                                               in exterior enclosure (TC7D-E)
+                                                                                                                                                   Carbon dioxide sensor/control -
+                                                                Module 1 - 2,442 lbs., Module 2 - 1,792 lbs.
+                                                             Assembled (1-piece) 240" L x 90" W x 78" H -                                             wall mount (CO2-W), duct mount (CO2-D)
+                                                                                                                                                   IAQ sensor - wall mount (IAQ-W), duct mount (IAQ-D)
+                                                                4,228 lbs.                                                                         Motion occupancy sensor/control -
+
+                                                             Motor(s): Qty. 2, Belt drive blower/standard motor                                       ceiling mount (MC-C), wall mount (MC-W)
+                                                                packages with choice of adjustable sheaves for low,                                Smoke Detector - duct mount (SD-D)
+                                                                medium or high blower speed. (see table below)                                     Electric duct heater - EK series (1–175 kW)
+                                                                                                                                                   Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                      (50-400 MBH), installed downstream of any fans
+
+Airflow                                                                                 External Static Pressure (in.w.g.)
+ CFM
+                    0.00       0.25                    0.50     0.75                   1.00          1.25                                          1.50            1.75             2.00
+                BHP RPM    BHP RPM                 BHP RPM
+                                                             BHP RPM BHP RPM                 BHP RPM                                          BHP RPM BHP RPM BHP RPM
+                1.6 640    1.6 670                 1.0 640
+                2.0 690    1.9 710                 1.2 660      3 HP LOW SPEED               3 HP MED SPEED                                                   3 HP HIGH SPEED
+                2.4 740    2.2 750                 1.4 680
+2500            2.8 790                            1.6 710      1.1 710 1.3 790              1.6                           870                1.8 930 2.1 1000 2.4 1050
+3000            3.3 830                            1.9 740
+3500            3.9 880                            2.2 770      1.3 730 1.5 810              1.8                           880                2.0 950 2.3 1010 2.6 1070
+4000                                               2.5 810      1.4 750 1.7 830                                                               2.3 960 2.6 1020 2.9 1080
+4500            4.5 930                                         1.6 770 1.9 840              2.0                           900                2.5 980 2.9 1040 3.2 1100
+5000            5.2 970
+5500            5.9 1010                                                                     2.2                           910
+6000            6.7 1040
+                7.5 1080                                        1.9 790 2.2 860              2.5                           930                2.8 990 3.2 1050 3.5 1110                     5 HP
+6500            8.4 1100                                                                                                                                                                   HIGH
+                                                                2.1 810 2.5 880              2.8                           940                3.1 1000 3.5 1060 3.9 1120                   SPEED
+7000                                                            2.5 840 2.8 900                                                               3.5 1020 3.8 1080 4.2 1130
+7500                                                                                         3.1                           960                                                             7.5 HP
+8000                                                                                                                                                                                        MED
+         3 HP                                                   2.8 870 3.1 920              3.5                           980                3.9 1040 4.2 1090 4.6 1150                   SPEED
+8500     LOW
+        SPEED              2.6 790 2.9 850 3.2 900 3.6 950 3.9 1000                                                                           4.3 1060 4.7 1110 5.1 1160                   7.5 HP
+9000                                                     Thermal Performance Ratings G5 2015.2.xlsx                                                                  10 Cores (IOM)        HIGH
+9500     5 HP                                                                                                                                                                              SPEED
+10000    LOW               3.1 830 3.4 880 3.7 930 4.0 980 4.4 1030                                                                           4.8 1080 5.2 1130 5.6 1170
+        SPEED              3.6 880 3.9 920 4.2 970 4.6 1010 4.9 1050                                                                          5.3 1100 5.7 1140 6.1 1190
+10500    5 HP
+         MED               4.2 920 4.5 960 4.8 1000 5.1 1040 5.5 1080                                                                         5.9 1120 6.3 1160 6.7 1200
+11000   SPEED
+        7.5 HP             4.8 960 5.1 1000 5.4 1030 5.8 1070 6.1 1100                                                                        6.5 1140 6.9 1180 7.3 1210
+         LOW
+        SPEED              5.5 1000 5.8 1030 6.1 1060 6.4 1100 6.8 1130                                                                       7.1 1160 7.5 1190 7.9 1220
+        7.5 HP             6.2 1040 6.5 1060 6.8 1090 7.1 1120 7.5 1150
+         MED               7.0 1070 7.3 1090 7.6 1120 7.9 1140 8.2 1170                                                                       7.8       1180  8.2  1210        8.5  1230   10 HP
+        SPEED                                                                                                                                 8.5       1190  8.9  1220        9.2  1240   HIGH
+
+                           7.8 1100 8.1 1120 8.4 1140 8.7 1160 9.0 1190                                                                       9.3 1210 9.6 1230 10.0 1250 SPEED
+
+                           8.6 1120 8.9 1140 9.2 1160 9.5 1180 9.8 1200
+
+                           10 HP MED SPEED                                                   10 HP HIGH SPEED
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.                                      CORE PERFORMANCE
+ELECTRICAL DATA
+
+                Standard Electrical Specifications                Optional Factory Installed                                                                  Airflow (CFM)
+                                                                VFD Electrical Specifications
+                                                                                                                                                         4000 6000 8000
+                                                   Max.                                      Max.
+
+HP      Volts   HZ  Phase     FLA Min. Cir.        Overcurrent     FLA Min. Cir.             Overcurrent                                          2000                              10000 12000
+                           per motor Amps          Protection   per motor Amps               Protection                                       90%
+                                                                                                                           Effectiveness (%)
+                                                   Device                                    Device
+
+3.0 208-230 60 Single 14.7-14 33.1                 40           9.38-8.48 40.2               45                                  70%
+
+    208-230 60 Three 9.38-8.48 21.1                25           9.38-8.48 23.2               25                                  50%
+
+3.0 460 60 Three 4.24            9.5               15           4.24                   10.5  15                                  30%
+                                                                                                                                        At AHRI 1060 standard conditions.
+        575 60 Three 3.3         7.4               15           3.3                    8.2   15                                         See all AHRI certified ratings at www.ahrinet.org.
+
+    208-230 60 Three 14.5-13.4 32.6                45           14.5-13.4 35.9               45                            Specifications may be subject to change without notice.
+
+5.0 460 60 Three 6.7             15.1              20           6.7                    16.6  20
+
+        575 60 Three 5.3         11.9              15           5.3                    13.1  15
+
+    208-230 60 Three 21.0-19.0 47.3                60           21.0-19.0 52.0               60
+
+7.5 460 60 Three 9.5             21.4              25           9.5                    23.5  25
+
+        575 60 Three 7.6         17.1              20           7.6                    18.8  20
+
+    208-230 60 Three 27.0-24.4 60.8                80           27.0-24.4 66.8               80
+
+10.0 460 60 Three 12.2           27.5              35           12.2                   30.2  35
+
+        575 60 Three 9.76        22.0              30           9.76                   24.2  30
+
+22 RENEWAIRE.COM 1.800.627.4499
+                                                                      LE10XINV  Energy Recovery Ventilator Standard
+
+                                                                                                                                                                      69 3/4"                                                              ABBREVIATIONS
+                                                                                                                                                                   Minimum                                                                 EA: Exhaust Air to outside
+                                                                                                                                                              Service Area                                                                 OA: Outside Air intake
+                                                                                                                                                                                                                                           RA: Room Air to be exhausted
+                                                                                                                                                                                Door      Door                                             FA: Fresh Air to inside
+                                                                                                                                                                                Swing     Swing                                            INSTALLATION ORIENTATION
+                                                                                                                                                                                                                                           Unit must be installed in orientation
+                                                                                                                                                                                                  34" Minimum                              shown.
+                                                                                                                                                                                                     Service Area                          NOTE
+                                                                                                                                                                                                                                           1. UNLESS OTHERWISE SPECIFIED,
+                                                                                                                                                              RA                                                   OA                      DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                           NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                        FA                                         EA                      2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                                                                                                                           TO CHANGE WITHOUT NOTICE.
+                                                                                                                                                          36" E-Box                                                                        3.DUCT CLEARANCE FROM
+                                                                                                                                                          Minimum                                                                          DAMPER BLADE WHEN FULLY
+                                                                                                                                                     Service Area                                                                          OPENED TO BE 2". SMACNA RULES
+                                                                                                                                                                                                                                           APPLY.
+
+                                                                                                                                                                                Door      Door    79 7/8"
+                                                                                                                                                                                Swing     Swing      Minimum
+
+                                                                                                                     13 3/8" X 15 1/2"                                      111" Minimum                 Blower
+                                                                                                                              Electrical                                    Service Area                    Service Area
+
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 23                          RA Damper                   Connection                           5" Damper        TOP VIEW                                                        OA Damper    OA Inlet
+                                                                                              Location                             Cover                      Frames Typ.                                                                       Location     48" X 24"
+                                                                                 RA Inlet (Optional)                                                                                 81 3/8"                                                    (Optional)   Duct Receiving
+                                                                               48" X 24"                                         E-Box                                              Overall                                                                  Flange
+                                                                      Duct Receiving                                    Disconnect                                                                                                         205 3/8" Overall
+                                                                                 Flange                                                              53 1/2"                                      Pressure                                  202 5/8" Case
+                                                                                                                               Switch                                                             Ports (4) Typ.
+                                                                                                                     47 1/4"
+
+                                                                                                                                   84 5/8"
+
+                                                                      71 1/8" Overall                                                                         RA                                  OA
+                                                                           69 5/8" Case
+                                                                                          41 5/8"                                                                                                                         8 7/8"                             41 5/8"
+                                                                                                             8 7/8"
+                                                                                                                                                              FA                                                   EA
+
+                                                                                47 3/8"                                CL 11 3/8"           29 5/8"           2" Typ.               69 1/8" Case                                  47 1/4"                                   47 3/8"
+                                                                                                                     (5) 1 1/8"                                  CL 2 1/4"                                                                         48" X 24"
+                                                                                                                      Knockouts                                     Wiring  4"          73 3/8"   2" Duct                                          Duct Receiving
+                                                                                                                                                                                       Lift Lugs  Flange Typ.                                      Flange Typ.
+                                                                                                                                            CL 5 1/4"
+                                                                                                LEFT VIEW                                   (2) 7/8"                            FRONT VIEW                                                 RIGHT VIEW
+                                                                      MAIoRdFLeOl:WLEC1O0XNIFNIGVURATION                                    Knockouts
+                                                                      DAvraailawbleinasgshToywnpined:imUennsiitonDdriamwiengn. sion                                                                                                                     UNIT MOUNTING & APPLICATION
+                                                                      Version: MAY18                                                                                                                                                                    Must be mounted as shown. RA/EA airstream can
+                                                                                                                                                                                                                                                        be switched with OA/FA airstream unless certain
+                                                                                                                                                                                                                                                        options are selected.
+
+                                                                                                                                                                            LE-SERIES
+SPECIFICATIONS & DIMENSIONS
+
+HLE 10XRT                                                Energy Recovery Ventilator
+                                                         Standard
+
+ROOFTOP UNIT                                             SPECIFICATIONS
+
+Download specification at:                               Ventilation Type:                                                                              Options:
+renewaire.com/specifications                             Static plate, heat and humidity transfer                                                       Spring vibration isolators
+                                                                                                                                                        Onboard variable frequency drives (VFDs) -
+AIRFLOW PERFORMANCE                                      Typical Airflow Range: 2,500-11,000 CFM
+                                                                                                                                                           one or both airstreams
+                                                         AHRI 1060 Certified Core: Ten L125-G5                                                           Shaft grounding ring on motors with VFDs
+                                                                                                                                                        Fused disconnect
+                                                         Standard Features:                                                                             Integrated programmable controls -
+                                                         TEFC Premium efficiency motors
+                                                         Motor starters                                                                                    enhanced, premium
+                                                         Non-fused disconnect                                                                           Class 1 low leakage motorized isolation dampers -
+                                                         24 VAC transformer/relay package
+                                                         Rubber vibration isolators                                                                        OA, RA or both
+                                                         Cross-core differential pressure ports                                                         Qty. 2, Factory mounted filter alarms -
+
+                                                         Filters:                                                                                          both airstreams
+                                                         Total qty. 20, MERV 8: 20" x 25" x 2"                                                          Double wall construction
+                                                                                                                                                        Exterior paint - white, custom colors
+                                                         Unit Dimensions & Weight:
+                                                         111 1/4" L x 205 1/2" W x 71 1/4" H                                                            Accessories:
+                                                         Modular (per module) 1,493-2,057 lbs., varies by option(s)                                     Filters - MERV 13, 2" or 4"; MERV 8, 4" (shipped loose)
+                                                         Assembled (1-piece) 3,032-3,993 lbs., varies by option(s)                                      Roof curb - standard 14"
+                                                                                                                                                        Curb wind clip
+                                                         Max. Shipping Dimensions & Weight (on pallet):                                                 Digital time clock - wall mount (TC7D-W),
+                                                         Modular (2-modules) 120" L x 90" W x 78" H
+                                                                                                                                                           in exterior enclosure (TC7D-E)
+                                                            Module 1 - 2,277 lbs., Module 2 - 2,245 lbs.                                                Carbon dioxide sensor/control -
+                                                         Assembled (1-piece) 240" L x 90" W x 78" H -
+                                                                                                                                                           wall mount (CO2-W), duct mount (CO2-D)
+                                                            4,433 lbs.                                                                                  IAQ sensor - wall mount (IAQ-W), duct mount (IAQ-D)
+                                                                                                                                                        Motion occupancy sensor/control -
+                                                         Motor(s):
+                                                         Qty. 2, Belt drive blower/standard motor packages                                                 ceiling mount (MC-C), wall mount (MC-W)
+                                                                                                                                                        Smoke Detector - duct mount (SD-D)
+                                                            with choice of adjustable sheaves for low,                                                  Electric duct heater - EK series (1–175 kW);
+                                                            medium or high blower speed. (see table below)
+                                                                                                                                                           designed for indoor ductwork installation only
+                                                                                                                                                        Indirect gas-fired duct furnace - GH series
+
+                                                                                                                                                           (50-400 MBH), installed downstream of any fans
+
+Airflow                                                                                 External Static Pressure (in.w.g.)
+ CFM
+                        0.00         0.25          0.50                                0.75            1.00               1.25                          1.50            1.75             2.00
+ 2500               BHP RPM      BHP RPM
+ 3000                                         BHP RPM BHP RPM BHP RPM BHP RPM                                                                      BHP RPM BHP RPM BHP RPM
+ 3500                            1.4 650
+ 4000                            1.7 680           3 HP LOW SPEED                                      3 HP MED SPEED                                              3 HP HIGH SPEED
+ 4500                            2.0 720
+ 5000                            2.4 760      1.0 640 1.2 740 1.5 820 1.7 880                                                                      2.0 950 2.3 1000 2.6 1060
+ 5500                            2.8 800
+ 6000                            3.3 850      1.1 660 1.4 760 1.7 830 2.0 900                                                                      2.3 960 2.6 1020 2.9 1070
+ 6500                            3.9 890
+ 7000                            4.5 930      1.3 690 1.6 770 1.9 850 2.2 920                                                                      2.5 980 2.9 1040 3.2 1090
+ 7500                            5.2 970
+ 8000                            5.9 1010     1.5 710 1.8 790 2.1 870 2.5 930                                                                      2.8       1000  3.2  1060        3.6  1110  5 HP HIGH
+                                 6.6 1050                                                                                                          3.2       1020  3.6  1070        3.9  1130    SPEED
+ 8500                                         1.7 740 2.1 810 2.4 890 2.8 950                                                                      3.5       1030  3.9  1090        4.4  1150
+
+ 9000                                         2.0 760 2.4 840 2.7 910 3.1 970
+
+ 9500               1.7 650                   2.4 T8h0e0rmal2P.7erfor8m70ance3R.1ating9s3G05 2031.55.2.x9ls9x0                                     3.9 1050 4.4 1101C10ores4(.I8OM)1170
+                                              2.8 830 3.1 890 3.5 960 4.0 1020                                                                     4.4 1080 4.8 1130 5.3 1190
+        3 HP LOW 2.1 690
+
+           SPEED 2.5 740                      3.2 870 3.6 930 4.0 980 4.4 1040                                                                     4.9 1100 5.3 1160 5.8 1210 7.5 HP
+
+                    3.0 790                   3.7 900 4.1 960 4.5 1010 5.0 1070                                                                    5.4 1120 5.9 1180 6.4 1230 HIGH
+
+        5 HP LOW 3.5 840                      4.3 940 4.7 990 5.1 1040 5.5 1100                                                                    6.0 1150 6.4 1200 6.9 1250 SPEED
+
+           SPEED 4.1 880                      4.9 980 5.3 1030 5.7 1070 6.1 1120                                                                   6.6 1170 7.0 1220 7.5 1270
+
+        5 HP MED    4.8    930                5.5 1010 5.9 1060 6.3 1100 6.8 1150                                                                  7.2 1200 7.7 1240 8.1 1290
+         SPEED
+
+        7.5 HP LOW 5.5 970                    6.2 1050 6.6 1090 7.0 1130 7.4 1170                                                                  7.8 1220 8.3 1260 8.7 1300 10 HP
+
+           SPEED 6.2 1010                     6.9 1080 7.3 1120 7.7 1160 8.1 1200                                                                  8.5       1240  8.9  1280        9.3  1310  HIGH
+                                                                                                                                                                                               SPEED
+
+10000   7.5 HP MED  7.0    1050  7.3  1080    7.7      1110  8.0                       1150       8.4    1180        8.7   1220                    9.1 1250 9.5 1290 9.9 1320
+          SPEED
+
+10500               7.8 1080 8.1 1110 8.4 1140 8.7 1170 9.1 1200 9.4 1230                                                                          9.7 1260
+
+11000               8.6 1110 8.9 1140 9.2 1160 9.4 1190 9.7 1220
+
+                           10 HP MED SPEED                                             10 HP HIGH SPEED
+
+Note: Airflow performance includes effect of clean, standard filter supplied with unit.
+
+ELECTRICAL DATA                                                                                                            CORE PERFORMANCE
+
+           Standard Electrical Specifications                  Optional Factory Installed                                                                          Airflow (CFM)
+                                                             VFD Electrical Specifications
+                                                                                                                                                              4000 6000 8000
+                                              Max.                                                           Max.                                      2000                                    10000 12000
+                                                                                                                                                   90%
+HP  Volts  HZ       Phase     FLA Min. Cir.   Overcurrent    FLA per                         Min. Cir. Overcurrent              Effectiveness (%)
+                           per motor Amps     Protection      motor                           Amps Protection
+
+                                              Device                                                         Device
+
+3.0 208-230 60 Single 14.7-14 33.1                 40        9.38-8.48 40.2                                  45                  70%
+
+    208-230 60 Three 9.38-8.48 21.1                25        9.38-8.48 23.2                                  25                  50%
+
+3.0 460 60 Three 4.24                 9.5          15        4.24                            10.5            15                  30%
+                                                                                                                                        At AHRI 1060 standard conditions.
+       575 60 Three 3.3               7.4          15        3.3                             8.2             15                         See all AHRI certified ratings at www.ahrinet.org.
+
+    208-230 60 Three 14.5-13.4 32.6                45        14.5-13.4 35.9                                  45            Specifications may be subject to change without notice.
+
+5.0 460 60 Three 6.7                  15.1         20        6.7                             16.6            20
+
+       575 60 Three 5.3               11.9         15        5.3                             13.1            15
+
+    208-230 60 Three 21.0-19.0 47.3                60        21.0-19.0 52.0                                  60
+
+7.5 460 60 Three 9.5                  21.4         25        9.5                             23.5            25
+
+       575 60 Three 7.6               17.1         20        7.6                             18.8            20
+
+    208-230 60 Three 27.0-24.4 60.8                80        27.0-24.4 66.8                                  80
+
+10.0 460 60 Three 12.2                27.5         35        12.2                            30.2            35
+
+       575 60 Three 9.76              22.0         30        9.76                            24.2            30
+
+24 RENEWAIRE.COM 1.800.627.4499
+                                                                      LE10XRT (RTV/RTR) Energy Recovery Ventilator Standard
+
+                                                                                                                                                                                            69 3/4" Minimum                                                                                                                      ABBREVIATIONS
+                                                                                                                                                                                                 Service Area                                                                                                                    EA: Exhaust Air to outside
+                                                                                                                                                                                                                                                                                                                                 OA: Outside Air intake
+                                                                                               CURB LE10X                                                                                                                                           Door   Door                             RA Damper                            RA: Room Air to be exhausted
+                                                                                                                                                                                                                                                    Swing  Swing                            Location                             FA: Fresh Air to inside
+                                                                                                   64 1/4" O.D.                                                                                                                                                                             (Optional)                           RTV: Rooftop Vertical RA & FA
+                                                                                                                                                                                                                                                                                                                                 RTR: Rooftop Vertical RA Only
+                                                                                      A                        A                                                                    FA (RTV)                                                                                                       OA                            INSTALLATION ORIENTATION
+                                                                                                                                                                                    (2) 16 1/8" X 16 3/8"                                                                                                                        Unit must be installed in orientation
+                                                                                                                                                                                    Openings                                                                                                 RA                                  shown.
+                                                                                                                                                                                                                                                                                             24" X 48"                           NOTE
+                                                                      195 1/4" O.D.                              9 1/2"                                                                                                                                                                      Opening                             1. UNLESS OTHERWISE SPECIFIED,
+                                                                           49"                                                                                                                                                                                                                                                   DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                 25"                                        191 1/2" I.D.                         EA                                                                                               OA                            NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                             18 1/4"                                                                                             2. SPECIFICATIONS MAY BE SUBJECT
+                                                                      20"                                         3"                                                                                                                                                                                                             TO CHANGE WITHOUT NOTICE.
+
+                                                                                               FA RA
+
+                                                                                                                                                                                                                                    85 1/4"                                                                                      CURB CROSS-SECTION A-A (TYP.)
+                                                                                                                                                                                                                                           58 1/4"
+                                                                                      41 1/8"                                                                                           FA   RTR                                                                                            72 1/8"                              1 1/2" X 1/4"    1 7/8"
+                                                                                                                                                                                            ONLY                                                                                                                                 Neoprene Gasket
+
+                                                                                                 60 1/2" I.D.                                                                                                                                               49 3/8"                                                              3/4" X 3 1/2"
+                                                                                                                                                                                                                                                                                                                                 Wooden Nailer
+                                                                                               TOP VIEW                                                                                                                                                  Door Door
+                                                                                                                                                                                      36" E-Box                                                          Swing Swing
+                                                                                                                                                                                      Minimum                                                                             79 7/8"  Minimum  Blower   Service  Area Typ.                                               14"
+                                                                                                                                                                                    Service Area                                                    111" Minimum
+                                                                                                                                                                                                                                                    Service Area
+FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 25         13 3/8" X 15 1/2"                           E-Box                                                                                                                                                              Pressure                     4 1/2"                                   3"
+                                                                                      Electrical                                                                                                                                                         TOP VIEW                           Ports
+                                                                                                                 Disconnect                                                                                                                                                                 (4) Typ.                             SECTION A-A
+                                                                                  Connection                            Switch                                                                                                                          111 1/4" Overall
+                                                                                           Cover                         84 5/8"                                                                                                                            69 1/8" Case                                                                  205 3/8" Overall
+                                                                                                                                                                                                                                                                                                                                           202 5/8" Case
+                                                                      44 5/8"                                    47 1/4"                                                                                                                                                                                                         93 5/8"
+
+                                                                      71 1/8" Overall                                                                                                                                               EA                                                      OA
+                                                                            69 5/8" Case
+                                                                                 37 7/8"                                                                                                                                            FA   RTR                              4"
+                                                                                                                                                                                                                                        ONLY
+                                                                                                          9"
+                                                                                                                      CL 11 3/8"                                                                                                    CL 2 1/4"        FA                                                                                                                 OA Inlets
+                                                                                                                                                                        FA1 1/8"                                                     Wiring          RTV                                                                                                              OA Damper
+                                                                                                                                                                               RA                                                                   ONLY
+                                                                                                                     Knockouts                                                                                                                                                                                                                                         Locations
+                                                                                                                                                                   29 5/8"                                                                                                                                                                                             (Optional)
+                                                                                                                                                                           53 1/2"HERT except 6x 8x, LERT
+
+                                                                                                                                                                                                                                RA
+                                                                                FA (RTR)                                                                                                                                                                   RA                                   2" Typ.
+                                                                                48" X 24"
+                                                                      Duct Receiving                                                                                                CL 5 1/4"                                       2" Duct                73 3/8"
+                                                                                                                                                                                                                                    Flange
+                                                                              Flange LEFT VIEW                                                                                      (2)HERT 7ex/c8ep"t 6x 8x, LETRyTp.                                    Lift Lugs
+                                                                                                                                                                                    Knockouts                                                                                                                                    RIGHT VIEW
+                                                                                                                                                                                                                                                    FRONT VIEW
+
+                                                                      DMAArovaIaRdiwlaFbeLilnelO:agsLWsETh1yoCw0pOnXe: N:RFUTIVGn/UitRRDTARimTIOeNnsion EA                 RTV              RTR                                                                                                                                  UNIT MOUNTING & APPLICATION
+
+                                                                                                                                                                                OA  EA                                                  OA                                                                                       Must be mounted as shown. Airstreams can not
+                                                                                                                                                                                                                                                                                                                                 be switched.
+                                                                      Version: MAY18                                                                                                    FA
+
+                                                                                                                                                                                                                                                    LE-SERIES
+                                                                                                                                                                                                                                                                                                                                     SPECIFICATIONS & DIMENSIONS
+26 RENEWAIRE.COM 1.800.627.4499
+LE10XRT (RTH/RTF) Energy Recovery Ventilator Standard                                                                                                                                                                       ABBREVIATIONS
+                                                                                                                                                                                                                            EA: Exhaust Air to outside
+                                                                                                                       69 3/4" Minimum                                                                                      OA: Outside Air intake
+                                                                                                                             Service Area                                                                                   RA: Room Air to be exhausted
+                                                                                                                                                                                                                            FA: Fresh Air to inside
+                                  CURB LE10X                                                                                                              Door      Door                                                    RTF: Rooftop Vertical FA Only
+                                                                                                                                                          Swing     Swing                                                   RTH: Rooftop Horizontal RA & FA
+                                      64 1/4" O.D.                                                                                                                                                                          INSTALLATION ORIENTATION
+                                                                                                                                                                                                                            Unit must be installed in orientation
+                                A                                                  A                                  FA (RTF)                                                                                              shown.
+                                                                                                                      (2) 16 1/8" X 16 3/8"                                                                                 NOTE
+195 1/4" O.D.                                                                      9 1/2"                             Openings                                                                                              1. UNLESS OTHERWISE SPECIFIED,
+     49"                                                                                                                                                                                                                    DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                           OA                               NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                            2. SPECIFICATIONS MAY BE SUBJECT
+                                                                                                                                   EA                                                                                       TO CHANGE WITHOUT NOTICE.
+
+                                                                                                                                                              18 1/4"
+                                                                                   25"    191 1/2" I.D.
+                                                                                                                                    85 1/4"
+                20"                                                                   3"                                                   58 1/4"
+
+                                   FA RA                                                                                                                                                                              CURB CROSS-SECTION A-A (TYP.)
+
+                                                                                                                      FA   RTH                                                   OA                                   1 1/2" X 1/4"
+                                                                                                                          ONLY
+                                                                                                                                                                                                                                       1 7/8"
+                41 1/8"                                                                                                                                                                                               Neoprene Gasket
+
+                                     60 1/2" I.D.                                                                                                         Door      Door                                              3/4" X 3 1/2"
+                                                                                                                                                          Swing     Swing                                             Wooden Nailer
+                                   TOP VIEW
+                                                                                                               36" E-Box                                                     79 7/8"                                                                                 14"
+                                                                                                               Minimum                                                          Minimum
+                                                                                                             Service Area
+                                                                                                                                                                                    Blower
+                                                                                                                                                      111" Minimum                     Service                                                                   3"
+                                                                                                                                                      Service Area                         Area Typ.
+                                                                                                                                                                                                                              SECTION A-A
+        13 3/8" X 15 1/2"                     E-Box                                                                                                       TOP VIEW              Pressure              4 1/2"
+                  Electrical       Disconnect                                                                                                                                   Ports                                                 205 3/8" Overall
+                                                                                                                                                           111 1/8" Overall     (4) Typ.                                               202 5/8" Case
+              Connection                   Switch                                                                                                             69 1/8" Case                                                  93 5/8"
+                      Cover                 84 5/8"                                                                                                                          OA
+
+44 5/8"                            47 1/4"
+
+71 1/8" Overall                                                                                                                          EA                                                                   8 7/8"
+    69 5/8" Case
+         37 7/8"                                                                                             53 1/2"                          RTH     4"
+                              9"                                                                                                             ONLY
+                                                                                                                                         FA                                  RA
+
+                                          FA (RTH)     CL 11 3/8"                                   29 5/8"                                               FA                        2"                             47 3/8"
+                                          48" X 24"  (5) 1 1/8"                                                                                                                  Typ.
+                                Duct Receiving        Knockouts                                                                          2" Duct          RTV, RTF                                    RA Inlet                          RA Damper                      OA Inlets
+                                                                                                                                                           ONLY              5" Damper                48" X 24"                         Location                     OA Damper
+                                                                                                                                                                             Frames Typ.              Duct Receiving                    (Optional)
+                                                                                                           CL 5 1/4"                Flange Typ.                                                       Flange                                                          Locations
+                                                                                                           (2) 7/8"                                                                                                         RIGHT VIEW                                (Optional)
+                                         Flange                                                            KnocHEkRoTeuxctespt  6x  8x,  CL 2 1/4"            73 3/8"
+                                                                                                                                         LERWT iring         Lift Lugs
+                                   LEFT VIEW HERT except 6x 8x, LERT
+                                                                                                                                                      FRONT VIEW
+
+DMAArovaIaRdiwlaFbeLilnelO:agsLWsETh1yoCw0pOnXe: N:RFUTIHGn/UitRRDTAFimTIOeNnsion          RTH                            RTF                                                                                                        UNIT MOUNTING & APPLICATION
+
+                                                                                   EA           OA           EA                              OA                                                                                      Must be mounted as shown. Airstreams can not
+                                                                                      FA                                                     RA                                                                                      be switched.
+                                                                                                RA
+
+Version: MAY18                                                                                                            FA
+                                                                                                       OPTIONS & ACCESSORIES
+
+OPTIONS
+
+See individual submittal pages for availability by model.
+
+ELECTRICAL
+u Disconnect fuses and motor starters
+u Independent blower control (IBC) -
+
+   available as an option for HE1X and
+   HE1.5X
+
+VARIABLE FREQUENCY DRIVE
+
+u Factory supplied and mounted variable       u Pre-programmed speeds or variable
+   frequency drives (VFDs)                       speed
+   - one or both airstreams
+                                              u Easy airflow setup using RenewAire’s
+u Provides additional control options            standard pressure ports
+                                                 - cuts commissioning time
+u Separate VFD for each airstream
+                                              u Shaft grounding ring on motors with
+u Display/control in electrical box - can be     VFDs
+   remotely mounted
+
+                                                                                      VFD all voltage     VFD
+                                                                                       except 575V     575V only
+
+MOTORIZED ISOLATION DAMPERS
+
+u Class 1, low leakage                        u Damper(s) are factory mounted and
+                                                 wired (except in HE1XIN - shipped
+u Robust, reliable actuators for highest         loose)
+   dependability
+
+u Automatic operation with spring return in
+   event of power loss
+
+FILTER ALARM
+
+u Factory mounted airflow switches -
+   one for each airstream
+
+u Allows for remote indication of loaded
+   (dirty) filter
+
+EXTERIOR PAINT
+u White and custom colors available
+
+                                                                                                  Specifications may be subject to change without notice.
+                                                           FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 27
+OPTIONS & ACCESSORIES
+
+OPTIONS
+
+Integrated Programmable Controls
+
+AVAILABLE ON ALL EV450, HE, LE, RD AND DN-SERIES UNITS
+
+RenewAire’s I N T E G R AT E D P R O G R A M M A B L E
+C O N T R O L S optimize the usability and performance of our
+commercial ERVs by improving functionality, enabling intelligent
+controls, streamlining operations and boosting efficiencies. This is
+accomplished via sophisticated factory-installed microprocessor
+controls and sensors that provide stand-alone ERVs with Direct Digital
+Control (DDC) and/or Building Management System (BMS) control
+interface.
+
+KEY BENEFITS
+
+Optimize usability:                                                    Increase capabilities:
+u Maximize ERV functionality and intelligent control via remote        u Expand ERV connectivity via access to a wide range of open
+
+   Ethernet accessibility and BMS connectivity without third-party        standard protocols, including BACnet and Modbus.
+   interface.
+                                                                       u Broaden ERV interoperability by connecting to third-party
+u Streamline operations by easily managing and changing ERV               equipment and receiving third-party signals for unit control.
+   control parameters via an advanced user interface.
+                                                                       u Expand ERV-application scope by meeting new code
+u Increase uptime reliability through constant system monitoring.         requirements and the needs of institutional customers
+                                                                          requiring DDC controls in mechanical equipment.
+u Achieve cleaner and healthier indoor air via IAQ-based ERV control.
+
+Improve performance:                                                   Simplify operations:
+u Support effective and efficient ERV performance with real-time       u Achieve easier ERV setup, commissioning and balancing via
+
+   data trending and logging capabilities.                               simple-to-install controls.
+
+u Enhance ERV control via access to real-time airflow rates,           u Improve operational efficiencies by easily communicating ERV
+   airstream temperature and airstream humidity.                          status, airflows, temperatures and humidity.
+
+u Facilitate fast and easy ERV upkeep and maintenance with             u Allow for more flexible installations by enabling ERVs to be
+   real-time fan, filter and bypass status.                              interconnected with a BMS, operated independently or run in
+                                                                         concert with other ERVs.
+
+A C C E S S O R I E S AVAILABLE WITH INTEGRATED PROGRAMMABLE CONTROLS
+
+ CO2 sensor (wall or duct mount)*                                      STANDARD       ENHANCED        PREMIUM
+ IAQ sensor (wall or duct mount)*                                      CONTROLS       CONTROLS       CONTROLS
+ Occupancy sensor (ceiling or wall mount)
+ Smoke detector (duct mount)                                                       u              u              u
+ BACnet factory activation (MS/TP or TCP/IP)                                       u              u              u
+ Remote display (handheld or wall mount)                                           u              u              u
+ Room Pressure Sensor (with or without display)                                    u                             u
+ Duct Static Pressure Sensor (with or without display)                                                           u
+ Temperature Sensor Kit (wall or duct mount)**                                                                   u
+                                                                                                                 u
+NOTES                                                                                                            u
+                                                                                                                 u
+*Sensor output is 0-10 vdc, for use as on/off or modulating control.
+**Temperature Sensor Kit is for use with non-integrated heating.
+
+Specifications may be subject to change without notice.
+
+28 RENEWAIRE.COM 1.800.627.4499
+                                                                                                                 OPTIONS & ACCESSORIES
+
+OPTIONS
+
+Integrated Programmable Controls
+
+MODELS                                               FEATURE COMPARISON
+
+STANDARD CONTROLS                                                                                                STANDARD
+                                                                                                                    CONTROLS
+via dry contact and relays                                                                                                 ENHANCED
+Our ERV units are provided with a dry contact                                                                                 CONTROLS
+that can be used to control the unit with a variety                                                                                  PREMIUM
+of low-voltage (24VAC) control devices such as                                                                                           CONTROLS
+remote switches or relays. In addition, third-party
+analog output can be used to operate the ERV.        Ability to automatically enable and disable unit            u  u                                    u
+
+ENHANCED CONTROLS                                    Enable the exhaust fan only (See note 1)                    u  u                                    u
+
+Carel [c.pCOMini] with or without BACnet             Filter alarm for both sets of filters (See note 2)           u  u                                    u
+Enhanced controls offer automated control,
+including temperature and humidity control with      Bypass controls† (See note 3)                               u  u                                    u
+data trending via microprocessor controls and
+sensors that enable BMS connectivity.                Control isolation dampers† (See note 4)                     u  u                                    u
+
+PREMIUM CONTROLS                                     Supply fan only modulation for VFD/EC Motor units†          u  u                                    u
+
+Carel [c.pCOMini] with expansion module              (See note 5 and 6)                                          u  u                                    u
+with or without BACnet
+Premium controls include all functionality of        Exhaust fan only modulation for VFD/EC Motor units†         u  u                                    u
+Enhanced-controls capabilities, as well as
+airflow and IAQ monitoring, demand control,           (See note 5 and 6)
+electric or gas heating options, as well as
+RD-Series cooling and heating control.               Internal time clock (See note 7)
+
+                                                     Defrost controls - Canada only                              u  u                                    u
+
+                                                     Smoke detection - sensor required (See note 8)              u  u                                    u
+
+                                                     Demand control ventilation using CO2 - sensor required u                                            u
+
+                                                     Occupancy-based ventilation - sensor required               u                                       u
+
+                                                     IAQ control ventilation using VOC - sensor required         u                                       u
+
+                                                     Microprocessor controller                                      u                                    u
+
+                                                     Provide supply and exhaust air temperatures                    u                                    u
+
+                                                     Provide outside and return air temperature and humidity†       u                                    u
+
+                                                     Fan status on both fans††                                      u                                    u
+
+                                                     Enable the supply fan only†                                 u  u                                    u
+
+                                                     Enable the exhaust fan only†                                u  u                                    u
+
+                                                     Micro USB port                                                 u                                    u
+
+                                                     Fieldbus port                                                  u                                    u
+
+                                                     BACnet MS/TP or BACnet TCP/IP - activation required            u                                    u
+
+                                                     Modbus                                                         u                                    u
+
+                                                     Data trending                                                  u                                    u
+
+                                                     Outside airflow rate                                                                                 u
+
+                                                     Exhaust airflow rate                                                                                 u
+
+                                                     Space pressure control                                                                              u
+
+                                                     Duct pressure control                                                                               u
+
+                                                     Unit supply air temp                                                                                u
+
+                                                     Heating enable                                                                                      u
+
+                                                     Heating modulation - staged or modulating                                                           u
+
+                                                     Cooling modulation* - staged or modulating                                                          u
+
+                                                     *RD-Series units only  †Not available on EV450              ††EF fan status not available on EV450
+
+                                                     NOTES FOR STANDARD CONTROLS ONLY                            5. VFD (option). Factory installed and wired.
+                                                                                                                 6. EC Motor (option) Potentiometer control factory wired.
+                                                      1. Relays and terminal block (option).                     7. Independent time clock (option).
+                                                      2. Differential pressure sensing tube and pressure switch  8. External smoke detector (option), field installed
+
+                                                          with manual trip point adjustment (option), wiring        in series to shut off unit in adverse conditions.
+                                                          to switch and alarm indication provided by others.
+                                                      3. Option on HE-Series (IN) and standard on RD-Series.
+                                                      4. 24V transformer contactors and relays (option).
+
+                                                                                                                 Specifications may be subject to change without notice.
+
+                                                                            FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 29
+OPTIONS & ACCESSORIES
+
+ACCESSORIES
+
+Standard Controls
+
+Standard controls are intended to turn RenewAire commercial energy recovery ventilation systems on and off at appropriate times.
+Specification, installation and set-up is an easy process. RenewAire HE, LE, and RD Series units come standard with a 24 volt
+transformer/relay package for easy interface with all controls.
+
+It is not necessary that RenewAire controls be used to operate RenewAire units. A wide range of controls or building automation
+systems may be used.
+
+*Available with Standard or Integrated Programmable Controls.
+**Only available with Integrated Programmable Controls.
+
+DIGITAL TIME CLOCK*
+
+u Up to 8 on/off cycles per day or 56 per u Battery back-up                                              box
+
+week                                                          u Wall mount or outdoor enclosure options
+
+u 24 VAC power requirement                                    u Wall mount fits any 4" x 4" electrical
+
+                                                                                                          TC7D-W
+                                                                                                         Wall Mount
+
+                                                                                                                         TC7D-E Control In
+                                                                                                                        NEMA 3R Enclosures
+
+CO2 SENSORS*                                                  u Self calibrates during periods of low
+u Adjustable control from 400-2000 PPM                           occupancy
+u Digital display
+u 24 VAC power requirement                                    u Wall mount or add duct mount accessory
+u Computer/BAS interface for information and
+                                                                                                                                       CO2-D
+   control                                                                                                                          Duct Mount
+
+                                                                                                           CO2-W
+                                                                                                         Wall Mount
+
+IAQ SENSORS*                                                  u Selectable 0-5 or 0-10V dc signal
+                                                              u 24 VAC power required
+u Measures TVOC                                               u Internal menu for easy set-up
+u Direct correlation to CO2 levels
+u 0-2000 ppm CO2 equivalent output                                                                                                     IAQ-D
+                                                                                                                                    Duct Mount
+   signal
+u Digital display on wall mount
+
+                                                                                                           IAQ-W
+                                                                                                         Wall Mount
+
+MOTION OCCUPANCY SENSORS*
+
+u Passive infared sensor                                      u Coverage floor space
+u Adjustable time-off delay to 30 minutes
+u 24 VAC power requirement                                       - Ceiling mount: 1500 sq. ft.
+u Ceiling mount or directable wall mount                         - Wall mount: 2500 sq. ft.
+
+                                                              u Major motion area                            MC-C                      MC-W
+                                                                                                         Ceiling Mount              Wall Mount
+                                                                 - Ceiling mount: 50 ft. diameter
+                                                                 - Wall mount: 68 x 50 ft.
+
+SMOKE DETECTOR*                                               u For 100-4000 fpm duct air velocity                         SD-D
+                                                                 applications                                           Duct Mount
+u Photoelectric type detector
+u Plug-in sensor                                              u 24 VAC power requirement
+u Round, square or rectangular duct
+                                                              u Interconnect feature for multi-fan
+   mounting options                                              shutdown
+u Easy access test/reset button and LED
+                                                              u Built-in short circuit protection
+   display
+
+      Specifications may be subject to change without notice.
+30 RENEWAIRE.COM 1.800.627.4499
+                                                                                          OPTIONS & ACCESSORIES
+
+ACCESSORIES
+
+Controls Continued
+
+REMOTE DISPLAY**
+
+u Hand held or wall mount
+u LED display
+u Keypad for easy programming
+
+                                                                                 RD-M
+                                                                       Handheld or Wall Mount
+
+PRESSURE SENSORS (ROOM PRESSURE/DUCT STATIC PRESSURE)**
+
+u With or without display
+
+u Differential pressure transmitter
+
+u 4-20 mA or field selectable 0-10 & 0.5V
+   output signal
+
+u Integral barbed tubing connections that
+   fit 1/8" and 3/16" ID tubing
+
+                                                                       RPS-WOD/DPS-WOD    RPS-WD/DPS-WD
+                                                                         Wall/Duct Mount  Wall/Duct Mount
+                                                                         without Display
+                                                                                             with Display
+
+BACNET FACTORY ACTIVATION**                                                               BN-A
+
+u Allows for communication to a BAS via
+   Bacnet NS/TP
+
+u Factory programmed and tested
+
+TEMPERATURE SENSOR KIT**
+u Duct temperature sensors
+u Hermetically sealed 304SS probe
+u Operating range -40F to 210F
+u Easy installation with integral
+
+   mounting plate
+
+Engineered Combo Curbs                                                                                                                TS
+                                                                                                                              Wall/Duct Mount
+Exclusively designed for select Trane (Voyager and Precedent)
+and Carrier (WeatherExpert, WeatherMaster, and Weathermaker)           Available Options (Special Order)
+models, RenewAire’s engineered combo curb makes it easy to             u Seismic and/or wind load applications
+combine standard Air Handling Unit (AHU) rooftop applications          u Pitched roof applications
+with the benefits of RenewAire energy recovery ventilation.            u High vibration applications
+They eliminate the need for transitional ductwork between the          u Custom curb heights
+RTU and the ERV, reducing the time and costs of installation.          u Heavier metal gauges
+Simply install the curb, run the return and supply duct to the         u Aluminum liners
+curb openings, then install the AHU and RenewAire units onto the
+curb. Additionally, the curbs allow the AHU unit to function in its
+standard operation as well as full-flow economizer modes.
+
+Standard Construction
+u Prime G-90, 18-gauge galvanized steel
+u Fully welded and mitered corners (single piece curb lift)
+u Base flange attachments for securing to the building structure
+u 1 ½" 3 lb. density fiberglass insulation
+u Reinforced with cross channel supports on center
+u Conforms to ASTM A653/A653M (standard specification for sheet metal)
+
+                                                                                                              Specifications may be subject to change without notice.
+                                                                       FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 31
+OPTIONS & ACCESSORIES
+
+ACCESSORIES
+
+EK Series Electric Duct Heater
+
+AVA I L A B L E O N A L L C O M M E R C I A L U N I T S ( S O M E E X C E P T I O N S A P P LY )
+
+RenewAire offers the highest-efficiency energy recovery ventilators (ERVs) on the market. However, during
+winter conditions, supply air from the ERV may be less than optimal for space conditions. By adding
+C O N F I G U R A B L E E L E C T R I C D U C T H E AT E R S as an accessory to our
+commercial ERVs, RenewAire can now heat supply air during cooler months to enhance indoor comfort,
+all via one package for ERVs and heaters from a single source.
+
+                                                                  FLIPPABLE
+                                                                      EK SERIES
+                                                                          SHOWN
+
+KEY BENEFITS
+
+u A single source reduces time and costs: A single information    u Ultimate reliability: RenewAire heaters come with our
+   source, a single purchase point and a single approval package     two-year warranty and unmatched reliability. Single-source
+   for ERVs and heaters reduces design time and costs, and           responsibility offers contractors and end users peace of
+   streamlines logistics for design engineers and contractors.       mind and a single call location for technical, start-up and
+                                                                     commissioning questions.
+u More flexibility: RenewAire offers design engineers the
+   capacity to specify ERVs with a matching heater to boost       u Highly certified: UL Listed (UL1996 Standard) and CSA certified.
+   flexibility and provide heated air to a single space or
+   multiple spaces.
+
+u Easy installation: A ZERO clearance rating to combustibles
+   allows designers and contractors to apply RenewAire heaters
+   with less restrictions onsite.
+
+      Specifications may be subject to change without notice.
+32 RENEWAIRE.COM 1.800.627.4499
+                                                                                                                                                                                        OPTIONS & ACCESSORIES
+
+EK SERIES                                                   Electric Duct Heater (1-175 kW)
+                                                            Accessory
+ELECTRIC DUCT HEATER
+                                                            SPECIFICATIONS
+Download specification at:
+renewaire.com/specifications                                Heater Type:                                                             Voltages & Phase:
+                                                            Electric Duct Heater                                                     Single phase - 120, 208, 240, 277
+                                                                                                                                     Three phase - 208, 240, 480, 600
+                                                            Typical KW Range:
+                                                            1–175 kW                                                                 Control Voltage:
+                                                                                                                                     24 VAC
+                                                            Standard Features:
+                                                            A disconnecting magnetic control contactor per                           Dimensions:
+                                                                                                                                     Minimum - 8" x 8" (W x H)
+                                                               stage or each 48 Amp circuit within a stage                           Maximum - 99" x 99" (W x H)
+                                                            Open-coil element
+                                                            Staged on/off                                                            Options:
+                                                            Control terminal board                                                   Flange mount
+                                                            Grounding lugs                                                           80-20 (Ni/Cr) A Grade element wire with
+                                                            Automatic limit switch for primary over-
+                                                                                                                                        stainless steel terminals
+                                                               temperature protection                                                Recessed control box 1"
+                                                            Manual reset limit switch for secondary over-                            Gasketed cover - dust tight
+                                                                                                                                     Power fusing, standard for heaters drawing more
+                                                               temperature protection
+                                                            Non-adjustable airflow switch                                                than 48 Amps
+                                                            Standard control transformer - 24 VAC                                    2-stage
+                                                            Disconnect switch                                                        Electronic step controller (4-stage)
+                                                            Duct thermostat with sensor for on/off control                           SCR (up to 96 Amps)
+                                                            60-20-20 (Ni/Cr/Fe) C Grade element wire with                            SCR Vernier (over 96 Amps)
+                                                                                                                                     Pilot light
+                                                               nickel-plated terminals
+                                                            Slip-in mount                                                            Accessory:
+                                                            No left/right hand                                                       Room thermostat
+                                                            Vertical up/down flow                                                     Room/duct thermostat-sensor kit for SCR control
+
+                                                            Note: Electric duct heater designed for indoor ductwork installation only.
+
+    EK SEREIKESSeHrieEsAHTeaEteRr CCaApaPcAityCITY                                                                                  PRESSURPEREDSRSOUPRETHDRROOPUGTHHRHOEUAGTHERHEATER
+
+200                                                                                                                           0.18
+
+175HEATER CAPACITY - kW                                                                                                       0.16                                                                            4
+
+150                                                                                   Static Pressure Drop - Inches of Water  0.14
+
+                                                                                                                                                                                                                              3
+
+                                                                                                                              0.12
+
+125                                                                                                                           0.1
+
+100                                                                                                                           0.08                                                                            2
+
+                                                                                                                              0.06
+
+75
+
+                    SAFE OPERATING                                                                                            0.04
+
+50                           RANGE                                                                                                                                                                                            1
+
+                                                                                                                              0.02
+
+25                                                                                                                            0
+                                                                                                                                 0
+                                                                                                                                     200
 400
 600
 800
 1000
 1200
 1400
 1600
 1800
 2000
 2200
+
+0                                                                                                                                    Air Velocity - FPM (1, 2, 3 and 4 - the number of rows of heater coils)
+                                                                                                                                       When the number of rows of heater coils is unknown, assume 4.
+     0  2500  5000  7500     10000                  12500
+
+              AIRFLOW - CFM
+
+        FLIPPABLE
+        CAPABILITIES
+
+        Unique to the EK series, this unit has the ability
+        to flip 180°. Additionally, EK heaters feature
+        both vertical up and vertical down airflow.
+
+                                                                                                                                                                            Specifications may be subject to change without notice.
+                                                                                                                                     FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 33
+                                                     T H I S PA G E I S I N T E N T I O N A L LY L E F T B L A N K .
+
+34 RENEWAIRE.COM 1.800.627.4499
+                                                                                                           OPTIONS & ACCESSORIES
+
+ACCESSORIES
+
+Indirect Gas-Fired Duct Furnace
+
+AVA I L A B L E O N A L L C O M M E R C I A L U N I T S ( S O M E E X C E P T I O N S A P P LY )
+
+RenewAire offers some of the highest-efficiency energy recovery ventilators (ERVs) on the market. However,
+during winter conditions, supply air from the ERV may be less than optimal for space conditions. By providing
+an indoor and outdoor I N D I R E C T G A S - F I R E D D U C T F U R N A C E as an accessory
+for our commercial ERVs, in addition to the Electric Duct Heater, RenewAire ERVs now have increased
+flexibility for controlling supply-air temperature during cooler months. This enhances indoor comfort, makes
+ERV installations easier and is possible via a single source for ERVs and furnaces.
+
+                                                                     GH OUTDOOR SERIES
+                                                                                                    SHOWN
+
+KEY BENEFITS
+
+u A single source for your ERV and furnace reduces time and          u Expert guidance: The RenewAire customer-support team will
+   costs: A single information source, a single purchase point and      provide detailed and expert guidance for how best to install the
+   a single approval package for ERVs and heaters reduces design        indoor and outdoor gas-fired duct furnace with an ERV.
+   time and costs, as well as streamlines logistics for design
+   engineers and contractors.                                        u Ultimate reliability: RenewAire furnaces come with our
+                                                                        two-year warranty and unmatched reliability. Single-source
+u Increased capabilities and flexibility: RenewAire offers              responsibility offers contractors and end users peace of
+   design engineers the capacity to specify ERVs with a matching        mind and a single call location for technical, start-up and
+   indoor or outdoor gas-fired furnace to increase ERV capabilities     commissioning questions.
+   and flexibility for providing a single space or multiple spaces
+   with tempered air conditions to equal wintertime loads.           u Highly certified: ETL-listed to the requirements of ANSI Z83.8/
+                                                                        CSA 2.6.
+u More and easier applications: The addition of the indoor
+   and outdoor indirect gas-fired duct furnace as an option
+   ensures that RenewAire ERVs can be easily specified on more
+   applications that require gas heating of the recovered air.
+
+                                                                                                            Specifications may be subject to change without notice.
+                                                                     FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 35
+OPTIONS & ACCESSORIES
+
+GH INDOOR Indirect Gas-Fired Duct Furnace
+                                                                 Accessory
+
+INDOOR                                                                       SPECIFICATIONS                                      Standard Features (continued):
+Indirect Gas-Fired Duct Furnace                                                                                                  Flame rollout switch
+                                                                             Heater Type:                                        Manual shut off valve
+                                              Indoor IN-KI shown             Indirect Gas-Fired Duct Furnace                     3/8" condensate drain connection
+Download specification at:
+renewaire.com/specifications                                                 Typical Input Capacity (MBH):                       Voltages & Phase:
+                                                                             50, 75, 100, 125, 150, 175,                         Single phase - 120V, 208V, 230V
+                                                                             200, 250, 300, 350, 400
+                                                                                                                                 Control Voltage:
+                                                                             Standard Features:                                  24 VAC
+                                                                             Tubular heaters
+                                                                             Indirect natural gas fired                           Dimensions:
+                                                                             Indoor installation                                 See table 2
+                                                                             80% thermal efficiency
+                                                                             Horizontal airflow                                   Shipping:
+                                                                             Rated for elevations from 0 – 2,000 ft.             Shipped loose with base unit and installed in the field
+                                                                             409 stainless steel heat exchanger
+                                                                             409 stainless steel burners                         Options:
+                                                                             Flue/combustion air – indoor models                 Indirect propane fired fuel
+                                                                                                                                 Elevation correction for elevation > 2,000 ft.
+                                                                                Vertical (separated indoor)                      304 stainless steel heat exchanger
+                                                                                Vertical top exhaust with louvered intake        5:1 continuous electronic modulation for all furnaces
+                                                                             Direct spark ignition                               10:1 continuous electronic modulation for furnaces
+                                                                             1-stage/2-stage gas controls
+                                                                             Induced draft venting                                  200 MBH and larger
+                                                                             Terminal block for power and control wiring         Duct thermostat for modulation control
+                                                                             Automatic high limit safety shut-off                Disconnect switch
+                                                                             Auxiliary manual high limit switch                  Power fusing
+                                                                             Combustion air pressure switch
+                                                                             Air proving switch                                  Accessory:
+                                                                             Combination gas valve with shutoff                  Duct thermostat for 1-stage/2-stage control
+                                                                                                                                 Duct thermostat for modulation control
+
+FLUE AND COMBUSTION AIR CONFIGURATION
+
+          IN-KI                            IN-SI                             Note: The total equivalent length of vent pipe must not exceed 50 feet. If equivalent length exceeds 50 feet refer
+     (TOP EXHAUST)            (SEPARATE INLET EXHAUST)                                to IOM for recommendations.
+
+  FLUE                                         FLUE           COMBUSTION     Caution: All indirect gas-fired duct furnaces to be installed downstream of the ERV and on the positive side of the
+EXHAUST                                      EXHAUST             INTAKE                   supply fan.
+
+AIRFLOW              AIRFLOW  AIRFLOW                               AIRFLOW
+
+         COMBUSTION
+            INTAKE
+
+TEMPERATURE RISE AND PRESSURE DROP
+
+    FIGURE 1 GAS FURNACE 50-200 MBH                                                                     FIGURE 2 GAS FURNACE 250-400 MBH
+
+                                      Gas Furnace 50 ‐ 200 MBH                                                                      Gas Furnace 250 ‐ 400 MBH
+
+60                                                                                      0.32        60                                                                                 1.6
+
+55                                                                                            0.28  55                                                                                 1.4
+
+50                                                                                 200              50                                                                                 1.2
+45
+40                                                                                            0.24
+Temperature Rise (deg. F)35                                                                                                                                                       400
+                                                                                                            Pressure Drop (inch‐w.c.)30
+                                                                                                                 Temperature Rise (deg. F)252001750.2045                400       350
+                                                                                                                                                                                                                              Pressure Drop (in.‐w.c.)20175
+                              150                                                       0.16                                                                       350                       1.0
+     0
+                                                                                                    40                                                                            300
+
+                                                                                                                                                             300                             0.8
+
+                                        125                                             0.12        35                     250                                               250       0.6
+                                 100
+                           75                                 150                       0.08        30                                                                                 0.4
+                     50                                        125
+                                                              100
+                                                                                        0.04        25                                                                                 0.2
+                                                      50/75
+
+         1000        2000                    3000     4000          5000     6000            0.00   20      3000  4000     5000  6000 7000 8000                                                                  0.0
+                                                                                        7000          2000                          Airflow (CFM)                            9000 10000 11000 12000
+
+                                             Airflow (CFM)
+
+      Specifications may be subject to change without notice.
+36 RENEWAIRE.COM 1.800.627.4499
+                                                                                                                                                                                                                                                                                                                               OPTIONS & ACCESSORIES
+
+       DUCT FURNACE DIMENSIONS                                                                                                                                                                             FIGURE 4 IN-SI (SEPARATE INLET EXHAUST INDOOR)
+       FIGURE 3 IN-KI (TOP EXHAUST INDOOR)
+                                                                                                                                                                22.92                                                                      FLUE GAS EXHAUST                                                                                                                   22.92
+                     FLUE GAS EXHAUST                                                                                                                            (H)                                                                                                D                                                                                                          (H)
+                                              D
+                                                                                                                                                     14.89                                                                        COMBUSTION AIR INLET                                                                                                     14.89
+       COMBUSTION AIR INLET                                                                                                                                                                                                                                      D
+
+                                                                                                          23.99                                                                                                                                                                                                  23.99
+                                                                                                                                                                                                                                                                                        OUTDOOR TOP EXHAUST (NO)
+                                                                               OUTDOOR TOP EXHAUST (NO)
+                                                                                                      47.85                                                                                                                                                                                               47.85
+                                                                                                        (L)                                                                                                                                                                                                 (L)
+
+                                                                W              UNLESS OTHERWISE SPECIFIED,  RenewAire LLC                                                        4510 Helgesen Dr.                                                                     W                UNLESS OTHERWISE SPECIFIED,       RenewAire LLC                                                               4510 Helgesen Dr.
+                                                                               DIMENSIONS ARE IN INCHES.                                                                     Madison, WI 53718 USA                                                                                      DIMENSIONS ARE IN INCHES.                                                                                  Madison, WI 53718 USA
+       TABLE 2                                                                 TOLERANCES:                                                                                                                                                                                              TOLERANCES:
+                                                                               LINEAR 0.015                                                                                     TEL: (608) 221-4499                                                                                                                                                                                                   TEL: (608) 221-4499
+                        LEVEL DESCRIPTION OF REVISION                          HOLE SIZE 0.005                                                                                  FAX: (608) 221-2824                                                                                                                                                                                                  FAX: (608) 221-2824
+                                                                               ANGULARITY 3                                                                                 TOLL FREE: (800) 627-4499                                                                                                                                                                                              TOLL FREE: (800) 627-4499
+         Size Tubes Input Rate                                                 SURFACE FINISH =                                                                                                                                                                                         LINEAR 0.015
+                                                                                                                                                                                                                                                                                        HOLE SIZE 0.005
+       DESCRIPTION OF REVISION                                                     63 MICROINCH MINIMUM     TITLE: HDG-400-M-N GAS HEATER OUTDOOR                                                                                                                                       ANGULARITY 3                      TITLE: HDG-400-M-N GAS HEATER OUTDOOR
+                                                                                                                                                                                                                                                                                        SURFACE FINISH =
+
+                                                                                                                                                                                                                                                                                            63 MICROINCH MINIMUM
+
+                                                                               MATERIAL:                                                DRAWN BY:        DATE:  DWG. NO.                                                                                                             -  MATERIAL:                                                     DRAWN BY:        DATE:  DWG. NO.
+                                                                         INDOOR TOP EXHAUST (KI) -
+                                                                                                            DO NOT SCALE DRAWING.       CAH          10/19/16         SK4750A                                                                                                                                             DO NOT SCALE DRAWING.       CAH          10/19/16         SK4750A
+                                                                                                            REMOVE ALL BURRS, BREAK                                                                                                                                                                                       REMOVE ALL BURRS, BREAK
+                                                                                                            SHARP EDGES.                                                                                                                                                                                                  SHARP EDGES.
+                                                                                                                                                                                                                                                                                                                          APPLICABLE STANDARDS: DIM.
+                                                                                                                                                                                                                                                                                                                          AND TOL. ANSI Y14.5
+                                                                                                            APPLICABLE STANDARDS: DIM.                                                                                                                                    Vent Locations INDOOR SEPARATED COMBUSTION (SI) DATE
+                                                                                                            AND TOL. ANSI Y14.5                                                                                                                                                                   FINISH:
+                                                                                 ReneMwiAni/rMe aLLxCTemperature Rise through Furnace (°F) FINISH:CHECKED BY:DATE:          SIZE A                                                                                                   BY                                                               CHECKED BY:      DATE:              SIZE A SHEET 1 OF 1
+
+                                                                               BY
+                                                                                   UNLESS OTHERWISE SPECIFIED,
+                                                                                   DIMENSIONS ARE IN INCHES.
+                                                                                   TOLERANCES:
+                                                                         DATE                                                           --           --         SCALE:1:16          SHEET 1 OF 1          4510 Helgesen Dr.       LEVEL DESCRIPTION OF REVISION                                                                                       --           --         SCALE:1:16
+                                                                                                                                                                                                       Madison, WI 53718 USA
+                                                                                                                                                                                                                                                                                                                                                                                          Shipping 4510 Helgesen Dr.
+                                                                                                                                                                                                          TEL: (608) 221-4499                                                                                                                                                                                                       Madison, WI 53718 USA
+                                                                                                                                                                                                         FAX: (608) 221-2824                                                                                                                                                                                                           TEL: (608) 221-4499
+                                                                                                                                                                                                       TOLL FREE: (800) 627-4499                                                                                                                                                                                                       FAX: (608) 221-2824
+                                                                               LINEAR 0.015                                                                                                                                                                                          UNLESS OTHERWISE SPECIFIED,          Unit RenewAire LLC                                               Weight TOLL FREE: (800) 627-4499
+                                                                                         HOLE SIZE 0.005
+                                                                                                            TITLE: HDG100-M-KI                                                                                                                                                    IN-KI, IN-SI DIMENSIONS ARE IN INCHES.  Diameter Weight TITLE: HDG100-M-KI
+                                                                   OutputANGULARITY 3                                                                                                                                                                                                               TOLERANCES:
+                                                                                         SURFACE FINISH =                                                                                                                                                                                           LINEAR 0.015
+                                                                           20 63 MICROINCH MINIMUM          25 30 DO NOT SCALE DRAWING.                         35DATE:     40 DWG. NO.                45                         50  55                         60                  HOLE SIZE 0.005
+                                                                                            MATERIAL:                                                                                                                                                                                ANGULARITY 3
+                                                                                                                                                   DRAWN BY:                                                                                                                         SURFACE FINISH =
+
+                                                                                                            REMOVE ALL BURRS, BREAK                                                 SK4700A                                                                            "W"           "L" "H" 63 MICROINCH MINIMUM         "D" DO NOT SCALE DRAWING.
+                                                                                                            SHARP EDGES.
+                                                                                                            APPLICABLE STANDARDS: DIM. CHECKED BY:                                                                                                                                                                                                        DRAWN BY:           DATE:  DWG. NO.
+                                                                                            FINISH:         AND TOL. ANSI Y14.5                                 DATE:                                                                                                                MATERIAL:
+                                                                                                                                                                                                                                                                                                                                                                                           SK4700A
+LEVEL                                                              DATE        BY                                                                                           SCALE:1:24   SIZE A SHEET 4 OF 4                                                                                                              REMOVE ALL BURRS, BREAK
+                                                                                                                                                                                                                                                                                                                          SHARP EDGES.
+                                                                                                                                                                                                                                                                                                                          APPLICABLE STANDARDS: DIM. CHECKED BY:
+                                                                                                                                                                                                                                                                                               FINISH:                    AND TOL. ANSI Y14.5                                 DATE:                   SIZE A
+
+       MBH Qty. Btuh                                                     Btuh                                                                                                                                    LEVEL DESCRIPTION OF REVISION                              DATE  BY                       inch                inch                                    lb                 SCALE:1:24                          SHEET 3 OF 4
+
+                                                                                                                                             Nom. Duct Opening Airflow (CFM)                                                                                            inch        inch                                                                                                       lb
+
+       50 3 50,000 40,000 1852 1481 1235 1058 926 823 741 673 617 15.7                                                                                                                                                                                                                                                                                             127                    207
+
+       75 3 75,000 60,000 2778 2222 1852 1587 1389 1235 1111 1010 926 15.7                                                                                                                                                                                                                                                                                         127                    207
+
+       100 4 100,000 80,000 3704 2963 2469 2116 1852 1646 1481 1347 1235 18.4                                                                                                                                                                                                                                                  5                                   142                    222
+       125 5 125,000 100,000 4630 3704 3086 2646 2315 2058 1852 1684 1543 21.2
+                                                                                                                                                                                                                                                                                                                                                                   169                    249
+
+       150 6 150,000 120,000 5556 4444 3704 3175 2778 2469 2222 2020 1852 23.9                                                                                                                                                                                                                                                                                     160                    240
+
+       175 7 175,000 140,000 6481 5185 4321 3704 3241 2881 2593 2357 2160 26.7 47.8 22.9                                                                                                                                                                                                                                                                           180                    260
+
+       200 8 200,000 160,000 7407 5926 4938 4233 3704 3292 2963 2694 2469 29.4                                                                                                                                                                                                                                                                                     196                    276
+
+       250 10 250,000 200,000 9259 7407 6173 5291 4630 4115 3704 3367 3086 34.9                                                                                                                                                                                                                                                                                    245                    325
+
+       300 12 300,000 240,000 11111 8889 7407 6349 5556 4938 4444 4040 3704 40.4                                                                                                                                                                                                                                               6                                   279                    384
+
+       350 14 350,000 280,000 12963 10370 8642 7407 6481 5761 5185 4714 4321 45.9                                                                                                                                                                                                                                                                                  324                    429
+
+       400 15 400,000 320,000 14815 11852 9877 8466 7407 6584 5926 5387 4938 48.7                                                                                                                                                                                                                                                                                  394                    499
+
+       Note: For a single furnace, 20° F minimum temperature rise, 60° F maximum temperature rise.
+       INDIRECT GAS-FIRED DUCT FURNACE DIMENSIONS
+
+                                                                                                                                                                                                                                                                       NOTES
+                                                                                                                                                                                                                                                                       1. UNLESS OTHERWISE SPECIFIED,
+
+                                                                                                                                                                                                                                                                               DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                                                                               NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                                                                                       2. SPECIFICATIONS SUBJECT TO
+                                                                                                                                                                                                                                                                               CHANGE WITHOUT NOTICE.
+
+                                                                                                                                                                            TOP VIEW
+
+                                                                                                                                               36"
+                                                                                                                                        Service Area
+
+            14 7/8"                                                                                                                                                                                                                                                                                     47 3/8"
+          Opening                                                                                                                                                                                                                                                                                        Case
+
+       6 1/8"                                                                                                                                                                                                                     View Port      25"                                                                                                                    14 7/8"
+                                                                                                                                                                                                                                                Case                                                                                                                   Opening
+
+                                                                                                                                                                                                                                                                                                                                                                               6 1/8"
+
+                                                                                                            24"                                                                                                                                                           24"
+
+                                                                         3"                                 Opening                                                                                                               3/8" Condensate                      Opening                                            3"
+                                                                         LEFT VIEW
+                                                                                                                          Power Wiring and                                                                                        Drain Tube
+
+                                                                                                                          Control Wiring                                                       3/4" Gas Connection                                                                      RIGHT VIEW
+                                                                                                                          Inlet Fittings                                    FRONT VIEW
+
+                                                                                                                                                                            UNLESS OTHERWISE SPECIFIED,                               RenewAire LLC                                  Specifications                        may  be       subject            to      change without 4510 Helgesen Dr.  notice.
+                                                                                                                                                                            DIMENSIONS ARE IN INCHES.                                                                                                                                                                 Madison, WI 53718 USA
+                                                                                                                                                                            TOLERANCES:                                                                                                                                                                                       TEL: (608) 221-4499
+                                                                                                                                                                                                                                                                                                                                                                       FAX: (608) 221-2824
+                                                                                                                                                                                                                                                                                                                                                                       TOLL FREE: (800) 627-4499
+                                                                                                                                                                            LINEAR 0.015
+                                                                                                                                                                            HDG100-M-KI DIM SPEC HOLE SIZE 0.005                                                                                                                                                                                                              37
+
+                                                                                                                                                                            ANGULARITY 3
+                                                                                                                                                                                                                                  FOTIRTLET:HE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM
+
+                                                                                                                                                                            SURFACE FINISH =
+                                                                                                                                                                            63 MICROINCH MINIMUM
+
+                                                                                                                                                                                                                                                                          DRAWN BY:                     DATE:             DWG. NO.
+OPTIONS & ACCESSORIES
+
+GH OUTDOOR Indirect Gas-Fired Duct Furnace
+                                                                           Accessory
+
+ROOFTOP                                                                                  SPECIFICATIONS                                     Standard Features (continued):
+Indirect Gas-Fired Duct Furnace                                                                                                             Combination gas valve with shutoff
+                                                                                         Heater Type:                                       Flame rollout switch
+                                          Rooftop RT-NO shown                            Indirect Gas-Fired Duct Furnace                    Manual shut off valve
+Download specification at:                                                                                                                  3/8" condensate drain connection
+renewaire.com/specifications                                                             Typical Input Capacity (MBH):
+                                                                                         50, 75, 100, 125, 150, 175,                        Voltages & Phase:
+                                                                                         200, 250, 300, 350, 400                            Single phase - 120V, 208V, 230V
+
+                                                                                         Standard Features:                                 Control Voltage:
+                                                                                         Tubular heaters                                    24 VAC
+                                                                                         Indirect natural gas fired
+                                                                                         Outdoor installation                               Dimensions:
+                                                                                         80% thermal efficiency                              See table 1
+                                                                                         Horizontal airflow
+                                                                                         Rated for elevations from 0 – 2,000 ft.            Shipping:
+                                                                                         409 stainless steel heat exchanger                 Shipped loose with base unit and installed in the field
+                                                                                         409 stainless steel burners
+                                                                                         Flue/combustion air – outdoor models               Options:
+                                                                                                                                            Indirect propane fired fuel
+                                                                                            Horizontal separated outdoor with hoods         Elevation correction for elevation > 2,000 ft.
+                                                                                            Vertical top exhaust with intake hood           304 stainless steel heat exchanger
+                                                                                         Direct spark ignition                              5:1 continuous electronic modulation for all furnaces
+                                                                                         2-stage gas controls                               10:1 continuous electronic modulation for furnaces
+                                                                                         Induced draft venting
+                                                                                         Terminal block for power and control wiring           200 MBH and larger
+                                                                                         Automatic high limit safety shut-off               Duct thermostat for modulation control
+                                                                                         Auxiliary manual high limit switch                 Disconnect switch
+                                                                                         Combustion air pressure switch                     Power fusing
+                                                                                         Air proving switch
+                                                                                                                                            Accessory:
+                                                                                                                                            Duct thermostat for 2-stage control
+                                                                                                                                            Duct thermostat for modulation control
+                                                                                                                                            Duct curb
+
+FLUE AND COMBUSTION AIR CONFIGURATION
+
+            RT-NO                                                      RT-WO             Caution: All indirect gas-fired duct furnaces to be installed downstream of the ERV and on the positive side of the
+       (TOP EXHAUST)                                              (FRONT EXHAUST)                     supply fan.
+
+                  FLUE
+               EXHAUST
+
+    AIRFLOW                              AIRFLOW         FLUE                   AIRFLOW
+                                                       EXHAUST
+
+                                                       AIRFLOW
+
+             COMBUSTION                                           COMBUSTION
+                INTAKE                                               INTAKE
+
+TEMPERATURE RISE AND PRESSURE DROP
+
+    FIGURE 1 GAS FURNACE 50-200 MBH                                                                                 FIGURE 2 GAS FURNACE 250-400 MBH
+
+                                      Gas Furnace 50 ‐ 200 MBH                                                                                  Gas Furnace 250 ‐ 400 MBH
+
+60                                                                                                  0.32        60                                                                                 1.6
+
+55                                                                                                        0.28  55                                                                                 1.4
+
+50                                                                                             200              50                                                                                 1.2
+
+                                                                                                          0.24
+Temperature Rise (deg. F)                                                                                                                                                                     400
+                                                                                                            Pressure Drop (inch‐w.c.)
+45                                                                                                                Temperature Rise (deg. F)2001750.2045                             400       350
+                                                                                                                                                                                                                              Pressure Drop (in.‐w.c.)
+                                                       175                                                                                                                                               1.0
+
+40                                                150                                               0.16                                                                       350            300
+
+                                                                                                                40                                                                                       0.8
+
+                                                                                                                                                                         300
+
+35                                                125                                               0.12        35                    250                                                250       0.6
+
+                                             100
+
+30                                       75                       150                               0.08        30                                                                                 0.4
+
+                                     50                                    125                      0.04        25                                                                                 0.2
+                                                                          100
+25
+                                                                  50/75
+
+20                                                                                                       0.00   20                                                                                                           0.0
+                                                                                                    7000          2000                                                                   9000 10000 11000 12000
+    0        1000                        2000          3000       4000          5000     6000                           3000  4000    5000  6000 7000 8000
+                                                                                                                                               Airflow (CFM)
+                                             Airflow (CFM)
+Specifications may be subject to change without notice.
+
+38 RENEWAIRE.COM 1.800.627.4499
+DUCT FURNACE DIMENSIONS                                                                                                                                                                                                             OPTIONS & ACCESSORIES
+FIGURE 3 RT-NO (TOP EXHAUST OUTDOOR)
+                                                                                                                                                              FIGURE 4 RT-WO (FRONT EXHAUST OUTDOOR)
+
+               FLUE GAS EXHAUST                                                                                        22.92                           FLUE GAS EXHAUST                                                                                                                  34.92
+                                        D                                                                               (H)                           COMBUSTION AIR INLET                                                                                                                (H)
+
+COMBUSTION AIR INLET                                                                                14.89                                                                                                                                                                       14.89
+
+                                                                                        23.99
+
+                                                                                 47.85                                                                                                                                                                   23.99
+
+                                           W                                     (L)
+
+                                                                                                                                                                                                              W                                  47.85
+
+                                                                                                                                                                                                                                                 (L)
+
+     TABLE 1                                     OUTDOOR TOP EXHAUST (NO)
+
+        Size Tubes                                  UNLESS OTHERWISE SPECIFIED,                                                    4510 Helgesen Dr.                                                                OUTDOOR FRONT EXHAUST (WO)
+                                                                                                                                    Madison, WI 53718 USA
+LEVEL DESCRIPTION OF REVISION                                                                                                          TEL: (608) 221-4499
+                                                                                                                                       FAX: (608) 221-2824
+
+                                                                                                                                   TOLL FREE: (800) 627-4499
+                                                    DIMENSIONS ARE IN INCHES.    RenewAire LLC
+                                                    TOLERANCES:
+                                                    LINEAR 0.015                 MHiDnG/M-4ax00T-eMm-pNerGatAuSreHREiAseTEtRhrOouUgThDFOuOrnRace (°F) TITLE:                                                     Vent Locations UNLESS OTHERWISE SPECIFIED,
+                                                    HOLE SIZE 0.005                                                                                                                                                                                          DIMENSIONS ARE IN INCHES.                                                4510 Helgesen Dr.
+                                                    ANGULARITY 3                                                                                                                                                             RenewAire LLC TOLERANCES:                                                                            Madison, WI 53718 USA
+                                                    SURFACE FINISH =                                                                                                                                                                                         LINEAR 0.015
+                                           Output63 MICROINCH MINIMUM                                                                                                                                                    Unit Shipping HOLE SIZE 0.005                                                                               TEL: (608) 221-4499
+                               Input Rate                                                                                                                                                                                                                                                                                            FAX: (608) 221-2824
+                                                                                                                                                                                                         RT-NO, RT-WO RT-NO RT-WO Diameter ANGULARITY 3                                                                          TOLL FREE: (800) 627-4499
+                                                                                                                                                                                                                                                             SURFACE FINISH =
+                                              -     MATERIAL:                                  DRAWN BY:        DATE:  DWG. NO.                                                                                           FRONT EXHAUWSTeiOghUtTDOWOeRig(hWt O) 63 MICROINCH MINIMUMTITLE:
+                                                                                 25 30 35 DO NOT SCALE DRAWING.
+                                                                                               CAH                       40SK475405A 50
+                                                                                 REMOVE ALL BURRS, BREAK
+                                                                                 SHARP EDGES.
+                                                                                 APPLICABLE STANDARDS: DIM.
+                                                                                 AND TOL. ANSI Y14.5
+                                                                      20                                    10/19/16                                          55                                     60
+
+                                                    FINISH:                                    CHECKED BY:      DATE:                                                                                    "W"        "L" "H" MATERIAL:            "H" "D" DO NOT SCALE DRAWING.  DRAWN BY:      DATE:  DWG. NO.
+                                                                                                                                                                                                                                                    REMOVE ALL BURRS, BREAK                    DATE:
+                                           DATE BY                                             --           --         SCALE:1:16  SIZE A SHEET 1 OF 1                                                                                                                                                HDG-400-M-W
+
+                                                                                                                                                                                                                                                 SHARP EDGES.
+                                                                                                                                                                                                                                                 APPLICABLE STANDARDS: DIM. CHECKED BY:
+                                                                                                                                                                                                                                 FINISH:         AND TOL. ANSI Y14.5                                                       SIZE A SHEET 1 OF 1
+                                                                                                                                                                      LEVEL DESCRIPTION OF REVISION           DATE                                                                                    SCALE:1:16
+                                                                                                                                                                                                                    BY
+                                                                                               Nom. Duct Opening Airflow (CFM)
+MBH Qty. Btuh                                 Btuh                                                                                                                                                       inch inch inch inch inch                                                              lb                          lb
+
+50 3 50,000 40,000 1852 1481 1235 1058 926 823 741 673 617 15.7                                                                                                                                                                                                                                127                207
+
+75 3 75,000 60,000 2778 2222 1852 1587 1389 1235 1111 1010 926 15.7                                                                                                                                                                                                                            127                207
+
+100 4 100,000 80,000 3704 2963 2469 2116 1852 1646 1481 1347 1235 18.4                                                                                                                                                                                                                         142                222
+                                                                                                                                                                             5
+                                                                                                                                                                                                                                                                                               169                249
+125 5 125,000 100,000 4630 3704 3086 2646 2315 2058 1852 1684 1543 21.2
+
+150 6 150,000 120,000 5556 4444 3704 3175 2778 2469 2222 2020 1852 23.9                                                                                                                                                                                                                        160                240
+
+175 7 175,000 140,000 6481 5185 4321 3704 3241 2881 2593 2357 2160 26.7 47.8 22.9 34.9                                                                                                                                                                                                         180                260
+
+200 8 200,000 160,000 7407 5926 4938 4233 3704 3292 2963 2694 2469 29.4                                                                                                                                                                                                                        196                276
+
+250 10 250,000 200,000 9259 7407 6173 5291 4630 4115 3704 3367 3086 34.9                                                                                                                                                                                                                       245                325
+
+300 12 300,000 240,000 11111 8889 7407 6349 5556 4938 4444 4040 3704 40.4                                                                                                                                                                                             6                        279                384
+
+350 14 350,000 280,000 12963 10370 8642 7407 6481 5761 5185 4714 4321 45.9                                                                                                                                                                                                                     324                429
+
+400 15 400,000 320,000 14815 11852 9877 8466 7407 6584 5926 5387 4938 48.7                                                                                                                                                                                                                     394                499
+
+Note: For a single furnace, 20° F minimum temperature rise, 60° F maximum temperature rise.
+
+INDIRECT GAS-FIRED DUCT FURNACE DIMENSIONS
+
+                                                                                                                                                                                                         NOTES
+                                                                                                                                                                                                         1. UNLESS OTHERWISE SPECIFIED,
+
+                                                                                                                                                                                                                 DIMENSIONS ARE ROUNDED TO THE
+                                                                                                                                                                                                                 NEAREST EIGHTH OF AN INCH.
+                                                                                                                                                                                                         2. SPECIFICATIONS SUBJECT TO
+                                                                                                                                                                                                                 CHANGE WITHOUT NOTICE.
+
+                                                                                        36"
+                                                                                 Service Area
+
+                                                                                                                              TOP VIEW                                                                                                           47 7/8"
+                                                                                                                                                                                                                                                  Case
+
+  14 7/8"                                                                                                                                                                                                Case                                                                                          14 7/8"
+Opening                                                                                                                                                                                                                                                                                               Opening
+                                                                                                                                                                                                         37" (WO) Shown
+6 1/8"                                                                                                                                                                                                                                                                                                    6 1/8"
+                                                                                                                                                              View Port                                  25" (NO)
+
+                                                                      24"                                                                                     3/8" Condensate                                           24"
+                                                                  Opening Power Wiring and                                                                    Drain Tube                                            Opening
+
+                                             3"                                  Control Wiring                                                   3/4" Gas Connection                                                                       3"
+                                           LEFT VIEW                             Inlet Fittings                               FRONT VIEW
+                                                                                                                                                                                                                                   RIGHT VIEW
+
+                                                                                                                              UNLESS OTHERWISE SPECIFIED,     RenewAire LLC                                                               Specifications  may   be     subject              to  change without 4510 Helgesen Dr.  notice.
+                                                                                                                              DIMENSIONS ARE IN INCHES.                                                                                                                                           Madison, WI 53718 USA
+                                                                                                                              TOLERANCES:                                                                                                                                                             TEL: (608) 221-4499
+                                                                                                                                                                                                                                                                                                      FAX: (608) 221-2824
+                                                                                                                                                                                                                                                                                               TOLL FREE: (800) 627-4499
+                                                                                                                              LINEAR 0.015
+                                                                                                                              FRONT EXHAUST OUTDOOR (WO) DIM SPEC HOLE SIZE 0.005
+                                                                                                                                                                                                                                                                                                                                                            39
+                                                                                                                              ANGULARITY 3
+                                                                                                                                                              FOTIRTLET:HE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM
+
+                                                                                                                              SURFACE FINISH =
+                                                                                                                                   63 MICROINCH MINIMUM
+
+                                                                                                                                                                                                                    DRAWN BY:             DATE:          DWG. NO.
+CERTIFICATIONS & PERFORMANCE
+
+AHRI 1060
+
+CERTIFIED PERFORMANCE
+
+Energy recovery component certified in accordance with AHRI Standard 1060-2013.
+Actual performance in packaged equipment may vary.
+
+                                       AHRI-1060 Certified Performance - Model Number L125-G5
+
+              Type                          Tilt Angle                          Nominal Airflow                                           Pressure Drop
+              Plate                            N/A
+                                                                                100% - 750 SCFM                                          0.65 in. H20
+                   Leakage Ratings                                              75% - 563 SCFM
+
+                                                                       Thermal Effectiveness Ratings at 0" Pressure Differential
+
+ Pressure     EATR               OACF  Purge Angle or  Nominal Airflow  Sensible Latent        Total   Net      Net                        Net           Net
+Differential                               Setting                                                   Airflow  Sensible                    Latent         Total
+-1 in. H20
+              1.0%               1.00  N/A             750 Heating     70%      52%           64%    750     70%                         52%            64%
+ 0 in. H20
+                                                       CFM Cooling     70%      42%           53%    CFM     70%                         42%            53%
+ 1 in. H20
+              0.0%               1.02  N/A
+
+                                                       563 Heating     74%      59%           69%    563     74%                         59%            69%
+
+              0.0%               1.05  N/A             CFM Cooling     74%      49%           58%    CFM     74%                         49%            58%
+
+NOTE: SCFM = Standard Cubic Feet per Minute OACF = Outdoor Air Correction Factor EATR = Exhaust Air Transfer Ratio N/A = Not Applicable
+
+40 RENEWAIRE.COM 1.800.627.4499
+                                                                                                                                            ORDERING & SUPPORT
+
+                                         LE SERIES MODEL
+                                    CONFIGURATION GUIDE
+
+                                          Note: Not all options are available on every model.
+
+MODEL NUMBER                                 J                                          --
+
+DIGIT NUMBER    123                  4     567             8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
+
+Digits 1 - 5:   Model                                                        Digit 18:  Flow Control
+"LE-6X"
+"LE-8X"                                                                      "-" = No Isolation Dampers
+"LE10X"                                                                      "D" = Motorized Damper both Airstreams
+                                                                             "E" = Motorized Damper EA or RA Airstream
+                                                                             "F" = Motorized Damper FA or OA Airstream
+
+ Digits 7 - 8: Location                                                      Digit 19:  Unit Control (see Restrictions 6 & 7)
+"IN" = Indoor
+"RT" = Rooftop                                                               "A" = Standard Unit Control Wiring
+                                                                             "V" = Onboard VFD Both Airstreams
+Digit 9:        Orientation                                                  "F" = Onboard VFD FA Airstream
+                                                                             "E" = Onboard VFD EA Airstream
+"V", "H" (Indoor Units)
+"V", "H", "R", "F" (Rooftop Units)                                                      Unit Fusing
+
+                                                                             Digit 20:
+
+Digit 10:       Vibration Isolation                                          "N" = Non-Fused (Standard)
+                                                                             "F" = Fused
+"N" = Neoprene Isolators
+"S" = Spring Isolators                                                                  Unit Control Enhancements
+
+                                                                             Digit 21:
+
+ Digit 11:      Wall Type                                                    "T" = Transformer with Isolation Relay (Standard)
+"S" = Single                                                                 "1" = Enhanced Controls
+"D" = Double                                                                 "2" = Premium Controls
+                                                                             "3" = Enhanced Controls with BACNET License
+Digit 12:       Phase (see Restriction 2)                                    "4" = Premium Controls with BACNET License
+
+"1" = Single Phase                                                           Digit 22:  Filter Options (see Restriction 8)
+"3" = Three Phase
+                                                                             "-" = None
+Digit 13:       Voltage (see Restriction 1)                                  "F" = Filter Monitor Both Airstreams
+
+"4" = 460V                                                                   Digit 23:  Flexible Packaging
+"5" = 208-230V
+"8" = 575V                                                                   "A" = Assembled (single piece flat bed)
+                                                                             "M" = Modular (two pieces for enclosed trailer)
+
+Digit 14:       FA Horsepower (see Restrictions 2, 3 & 4)
+
+"D" = 3 HP Low Speed                                                         Digit 24:  Paint and Customization
+"F" = 3 HP Medium Speed
+"G" = 3 HP High Speed                                                        "-" = None
+"J" = 5 HP Low Speed                                                         "W" = White Paint
+"K" = 5 HP Medium Speed                                                      "C" = Custom Paint
+"L" = 5 HP High Speed                                                        "X" = Custom Unit
+"M" = 7.5 HP Low Speed
+"N" = 7.5 HP Medium Speed                                                    Digit 25:  Safety Listing (see Restriction 5)
+"P" = 7.5 HP High Speed
+"Q" = 10 HP Medium Speed                                                     "L" = Listed
+"R" = 10 HP High Speed                                                       "N" = Non-Listed
+
+Digit 15:       EA Horsepower (see Restrictions 2, 3 & 4)
+
+"D" = 3 HP Low Speed
+"F" = 3 HP Medium Speed
+"G" = 3 HP High Speed
+"J" = 5 HP Low Speed
+"K" = 5 HP Medium Speed
+"L" = 5 HP High Speed
+"M" = 7.5 HP Low Speed
+"N" = 7.5 HP Medium Speed
+"P" = 7.5 HP High Speed
+"Q" = 10 HP Medium Speed
+"R" = 10 HP High Speed
+
+*NOTES:                      Digits 16 and 17 are not used in these models.
+Digit 6 "J" = G5 Core Type
+
+Restrictions:
+ 1: Voltage Codes "4" & "8" only available with Phase Code "3" (Three-Phase).
+ 2: Phase Code "1" only available in Motor Codes "D", "F" & "G".
+ 3: Motor Code "P" (7.5 HP High Speed) not available in LE-6X.
+ 4: Motor Codes "Q" and "R" (all 10 HP Speeds) not available in LE-6X & LE-8X.
+ 5: Some units with Customization Code "X" are not safety listed.
+ 6: Unit Control Codes "V", "E" & "F" only available with Motor Codes "G", "L" & "N" in LE-6X.
+ 7: Unit Control Codes "V", "E" & "F" only available with Motor Codes "G", "L", "P" & "R" in LE-8X & LE-10X.
+ 8: Filter Code "F" not available with Unit Control Enhancements Codes "1", "2", "3" & "4". Filter Monitor is provided with those options.
+
+                                 For Technical SupLpEortMEO-mDEaiLl:SRenewaireSupport@renewaire.com
+                                   CToOMPlaMcEeRaCnIOArLdePrREO-mDaUilC: RTeCneOwDaEireCOHrAdeRrsT@renewaire.com
+
+                                                                             FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 41
+ORDERING & SUPPORT
+
+         EK SERIES ELECTRIC DUCT HEATER
+                     CONFIGURATION GUIDE
+
+                                  Note: Not all options are available on every model.
+
+MODEL NUMBER                 -
+
+DIGIT NUMBER    123                  4      567                8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
+
+Digits 1 - 2: Heater Type                                                                        Digit 18:   Voltage (see Restrictions 7 & 8)
+"EK "= Electric Heater (Standard)                                                              "1" = 120V
+                                                                                               "2" = 208V
+ Digits 4 - 5:  Width in Inches (see Restriction 1)                                            "3" = 240V
+08-99                                                                                          "4" = 480V
+                                                                                               "8" = 600V
+                                                                                               "9" = 277V
+
+ Digits 6 - 7:  Height in Inches (see Restriction 2)                                           Digit 19:     Phase
+08-99
+                                                                                               "1" = Single-Phase
+ Digits 8 - 10: Capacity in kW (see Restrictions 3, 4 & 5)                                     "3" = Three-Phase
+001-175
+                                                                                                Digit 20:    Power Fusing (see Restriction 9)
+                                                                                               "-" = None
+Digit 11:       Mount                                                                          "F" = Fusing
+
+"S" = Slip In (Standard)                                                                       Digit 21:     Stage
+"F = Flanged
+
+Digit 12:       Element Style                                                                  "1" = Single (Standard)
+                                                                                               "2" = 2-Stage
+"C" = Open Coil (Standard)                                                                     "4" = 4-Stage
+
+Digit 13:       Element Material                                                               Digit 22:     Control Voltage
+
+"C" = 60-20-20 Ni-Cr-Fe with Nickel Plate Terminal Pins (Standard)                             "S" = 24VAC
+"A" = 80-20 Ni-Cr with Stainless Steel Terminal Pins
+
+Digit 14:       Airflow Orientation                                                            Digit 23:     Control Type (see Restrictions 10, 11 & 12)
+
+"H" = Horizontal (Standard)                                                                    "D" = Duct Thermostat with Sensor (Standard)
+"V" = Vertical                                                                                 "E" = Electronic Step Control with Sensor
+                                                                                               "S" = SCR (For BAS System)
+Digit 15:       Control Box Offset                                                             "V" = SCR with Analog Sensor (0-10Vdc)
+
+"L" = Left Hand (Standard)                                                                     Digit 24:     Time Delay
+"R" = Right Hand
+
+                                                                                               "-" = None (Standard)
+
+Digit 16:       Control Box Recessed
+
+"-" = None (Standard)                                                                          Digit 25:     Pilot Light
+"R" = Recessed 1"
+                                                                                               "N" = None (Standard)
+Digit 17:       Control Box Dust Tight                                                         "L" = Light
+
+"-" = None (Standard)
+"D" = Dust Tight
+
+*NOTES:
+Digit 3 is not used in this model.
+All heaters come with standard features: Disconnect Switch, Air Flow Switch (non adjustable), Control Transformer
+Descriptions of feature and options are found in the installation and operation manual.
+
+Restrictions:
+
+1: Width inches entered as a whole number.
+2: Height inches entered as a whole number.
+3: Heater density should be less than 30kW/ft². DENSITY= HEATER CAPACITY (kW) < 30
+                                                                     (W" x H")/144
+4: Heater capacity kW entered as a whole number.
+5: Formulas for calculating kW and temperature rise: kW = CFM x ΔT             ΔT = kW x 3150
+                                                      3150                          CFM
+7: Voltage Codes "1" & "9" only available with Phase Code "1" (Single-Phase).
+8: Voltage Codes "4" & "8" only available with Phase Code "3" (Three-Phase).
+9: Power Fusing Code "F" required when amperage is >48A. (based on kW and voltage)
+10: Control Type Code "D" only available with Stage Code "1" & "2".
+11: Control Type Code "E" only available with Stage Code "4".
+12: Control Type Code "S" & "V" only available with Stage Code "1", unless amperage is greater than or equal to 96A, then Stage Code "4" is automatically selected.
+
+                                             For TechnicEalLSEupCpoTrtREI-CmaPil:OReSnTewHairEeSAuTpport@renewaire.com
+                                               ToCPOlacNeFanIGOUrdeRr AE-TmIaOil:NReCneOwaDireEOrCdeHrsA@RreTnewaire.com
+
+42 RENEWAIRE.COM 1.800.627.4499
+                                                                                                                                                                              ORDERING & SUPPORT
+
+GH SERIES INDIRECT GAS-FIRED DUCT
+    FURNACE CONFIGURATION GUIDE
+
+                          Note: Not all options are available on every model.
+
+MODEL NUMBER                 -                                                                                -                                               --
+
+DIGIT NUMBER      123                  4  567  8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
+
+Digits 1 - 2: Duct Furnace Type                                              Digit 17:     Disconnect Switch
+"GH" = Gas Furnace 50-400 MBH
+                                                                             "N" = None (Standard)
+                                                                             "D" = Disconnect Switch
+
+ Digits 4 - 5: Location                                                       Digit 18:    System/Inducer Voltage (see Restriction 2)
+"IN" = Indoor                                                                "1" = 115V
+"RT" = Rooftop                                                               "2" = 208V
+                                                                             "3" = 230V
+  Digits 6 - 7: Vent Location
+"SI" = Separated Top Indoor                                                  Digit 19:     Phase
+"KI" = Top Exhaust Indoor
+"WO" = Front Exhaust Outdoor                                                 "1" = Single Phase
+"NO" = Top Exhaust Outdoor
+                                                                              Digit 20:    Power Fusing (see Restriction 3)
+                                                                             "N" = None
+  Digits 8 - 10: Input Capacity in MBH                                       "F" = Fusing
+"050", "075", "100", "125", "150", "175", "200", "250", "300", "350", "400"
+
+                  Fuel Type                                                  Digit 22:     Control Voltage
+
+Digit 11:                                                                    "S" = 24VAC
+
+"N" = Natural Gas (Standard)                                                 Digit 23:     Control Type (see Restriction 1)
+"P" = Propane
+
+Digits 12 - 13: Tube Material                                                "T" = Two Stage High/Low with Thermostat (Standard)
+"SS" = 409 Stainless Steel (Standard)                                        "S" = Single Stage On/Off with Thermostat
+"CS" = 304 Stainless Steel                                                   "E" = Modulating 5:1 (Natural Gas)/3:1 (Propane) with Thermostat
+                                                                             "W" = Modulating 10:1 (Natural Gas)/6:1 (Propane) with Thermostat
+Digit 14:         Airflow Orientation                                        "2" = Two Stage High/Low without Thermostat
+                                                                             "1" = Single Stage On/Off without Thermostat
+"H" = Horizontal                                                             "M" = Modulating 5:1 (Natural Gas)/3:1 (Propane) without Thermostat
+                                                                             "V" = Modulating 10:1 (Natural Gas)/6:1 (Propane) without Thermostat
+                  Thermal Efficiency
+ Digit 15:
+"S" = 80%
+
+Digit 16:         Elevation
+
+"S" = 0 - 2000' (Standard)
+"2" = 2001'- 3000'
+"3" = 3001' - 4000'
+"4" = 4001' - 5000'
+"5" = 5001' - 6000'
+"6" = 6001' - 7000'
+"Y" = 7001' and above
+
+*NOTE:
+Digits 3, 21, 24 & 25 are not used in this model.
+All heaters come with standard features: Air Proving Switch, Auxiliary High Temperature Limit Switch
+Descriptions of feature and options are found in the installation and operation manual.
+
+Restrictions:
+ 1: Control Type Code "V" & "W" not available with Input Capacity in MBH Codes "050", "075", "100", "125", "150" & "175".
+ 2: System/Inducer Voltage Code "2" not available with Input Capacity in MBH Codes "050", "075", "100", "125" , "150", "175" & "200".
+ 3. Power Fusing Code “F” only available with Disconnect Switch Code “D”. Power Fusing Code “F” always selected when Disconnect Switch Code “D” is selected.
+
+                                                 GAS HEAT CONFIGURATION
+                                          For Technical SuppCoOrt DE-EmaCil:HRAenRewTaireSupport@renewaire.com
+
+                                            To Place an Order E-mail: RenewaireOrders@renewaire.com
+
+                                                                                                         FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM 43
+ORDERING & SUPPORT
+
+                    INDOOR AIR QUALITY MATTERS
+
+                    u Deficient IAQ is an EPA top-five health risk
+
+                    u People spend 90% of their time indoors
+
+                    u Indoor air can be 2-5 times and up to 100 times
+                       more polluted than outdoor air
+
+BENEFITS OF INCREASED VENTILATION
+
+                                 BETTER          IMPROVED   INCREASED
+                                 HEALTH          COGNITIVE  PRODUCTIVITY
+                                                 FUNCTION
+
+TECHNICAL/APPLICATIONS SUPPORT
+The goal of our technical-support team is to provide the BEST CUSTOMER SERVICE
+in the HVAC industry. You can count on our knowledgeable and seasoned staff for all your technical,
+application and service needs, and we’ll respond quickly and effectively to answer any of your questions.
+
+                    CONTACT RENEWAIRE
+
+                                 PHONE:          FOR TECHNICAL SUPPORT:
+                                 1.800.627.4499  RenewaireSupport@renewaire.com
+
+                                 FAX:            TO PLACE AN ORDER:
+                                 608.221.2824    RenewaireOrders@renewaire.com
+
+44 RENEWAIRE.COM 1.800.627.4499
+RELEVANT                                                           RENEWAIRE
+
+EVERYWHERE                                                  TEMPERS THE AIR
+
+EVERY GEOGRAPHIC REGION                                    Our ERVs moderate the extremes
+Our ERVs function perfectly across the world in every      of outdoor supply-air temperature
+geographic region.                                         and humidity year-round, providing
+                                                           a sustainable solution for fresh air
+EVERY CLIMATE                                              that feels like a perfect spring day.
+Our ERVs operate in every climate—from Alaska to
+Florida, and everywhere in between.
+
+EVERY PROJECT
+From massive skyscrapers to cozy residential homes,
+our ERVs can be used in every size project and in every
+code jurisdiction.
+
+APPLIED EVERYWHERE
+
+When indoor occupants breathe in unclean air, this harms their health and causes cognitive impairment. Our ERVs can
+provide cleaner and healthier indoor air for every type of building in the world, thus improving occupants’ wellbeing,
+while also reducing energy costs.
+
+RESIDENTIAL                                                DAYCARE
+The increased airtightness of newer and remodeled          Crowded daycare facilities breed deficient IAQ, thus
+homes is causing deficient IAQ, resulting in more health   causing health problems for everyone—especially
+problems for indoor occupants.                             children who are more vulnerable.
+
+COMMERCIAL                                                 EDUCATION (LOWER AND HIGHER)
+As commercial buildings become more airtight,              With students and teachers packed into tight classrooms,
+deficient IAQ is increasing and causing sickness,          instances of deficient IAQ go up, resulting in academic
+absenteeism and decreased productivity.                    performance and test scores going down.
+
+H E A LT H C A R E                                         GOVERNMENT
+The high occupant density of hospitals, nursing homes      Aging and crowded government buildings result in
+and other healthcare facilities results in deficient IAQ   deficient IAQ, which can impair worker performance
+and ensuing health problems for patients and staff alike.  and productivity.
+
+RESTAURANTS/COFFEE SHOPS                                   EVERY TYPE OF BUILDING
+The large volume of indoor occupants in restaurants        Every type of building can benefit from the enhanced
+and coffee shops causes deficient IAQ and subsequent       IAQ generated by RenewAire ERVs, including
+health problems.                                           veterinary clinics, nail salons and manufacturing
+                                                           facilities, among others.
+RETAIL
+The high level of foot traffic in retail stores leads
+to deficient IAQ and the potential sickness of shoppers,
+which can negatively impact sales.
+        RENEWAIRE EVERYWHERE                                       LIT115_00 (01/19)
+
+       RenewAire ERVs can be applied everywhere across all
+         commercial, educational, institutional, light industrial
+
+      and residential buildings. Our technology excels in every
+     geographic region, every climate, and every size project.
+
+Member of the S&P Group
+Family of Brands
+

+ 201 - 0
media/documents/pdf/ERV_Guide.pdf

@@ -0,0 +1,201 @@
+ERV GUIDE
+
+               INDOOR AIR QUALITY MATTERS
+
+                 u Deficient IAQ is an EPA top-five health risk
+                 u People spend 90% of their time indoors
+                 u Indoor air can be 2–5 times and up to 100
+
+                      times more polluted than outdoor air
+
+BENEFITS OF INCREASED VENTILATION
+
+BETTER  IMPROVED   INCREASED
+HEALTH  COGNITIVE  PRODUCTIVITY
+        FUNCTION
+
+       RENEWAIRE EVERYWHERE
+
+E V E R Y G E O G R A P H Y, E V E R Y C L I M AT E , E V E R Y H O M E ,
+           EVERY BUILDING AND EVERY APPLICATION
+DEFICIENT INDOOR AIR QUALITY                                                                                                                                                                  RENEWAIRE ERVs
+
+T H R E AT E N S O C C U PA N T H E A LT H                                                                                                                                                    ACHIEVE SUSTAINABLE IAQ
+
+AS NEW BUILDINGS GET TIGHTER TO SEAL WEATHER OUT,                                                                                                                                             RenewAire is A P I O N E E R I N E N H A N C I N G I A Q while maximizing sustainability
+T H E Y S E A L I N C O N TA M I N A N T S , causing deficient indoor air quality (IAQ), which                                                                                                through enthalpic-core, static-plate ERVs that O P T I M I Z E E N E R G Y E F F I C I E N C Y ,
+impacts health and cognitive function. R EN E WA I R E ’ S E NE R G Y R E C O VE RY                                                                                                           lower costs by R E D U C I N G H VA C L O A D S and therefore reduce environmental
+VENTILATORS (ERVs) ARE THE SUSTAINABLE SOLUTION.                                                                                                                                              footprints. Our ERV technology preconditions incoming air with the otherwise-wasted sensible and
+RenewAire ERVs improve IAQ by diluting contaminants such as off-gassing from carpeting, furniture                                                                                             latent energy (heat and humidity) of the exhaust air going out—all while the airstreams are kept
+and building materials, excess humidity and mold, odors, pollutants and contaminants from cooking and                                                                                         physically separate as certified by the Air Conditioning, Heating and Refrigeration Institute (AHRI) for
+cleaning, carbon dioxide, hair and fibers.                                                                                                                                                    zero exhaust air transfer at normal balanced operating conditions. As the pioneer of static-plate core
+                                                                                                                                                                                              technology in North America, RenewAire is the largest ERV producer in the USA.
+   HEALTH                                  LEARNING                                  PRODUCTIVITY
+   MATTERS                                 MATTERS                                   MATTERS                                                                                                  HIGHEST-QUALITY INDOOR AIR
+                                                                                                                                                                                              Stale indoor air is replaced with fresh, conditioned and filtered
+Deficient IAQ needs to be addressed since  Standardized test scores can increase by  Doubling the ventilation rate from 20                                                                    outdoor air, resulting in enhanced IAQ by removing harmful
+people spend about 90% of their time       10% when ventilation rates are doubled.2  CFM to 40 CFM per person costs only $32                                                                  contaminants from the indoor air. Airstreams do not mix and
+indoors according to the National Safety                                             per person and improves productivity                                                                     pollutants are not transferred across partition plates.
+Council (NSC).1                                                                      $6,500 per person per year.3                                                                             OPTIMIZING ENERGY EFFICIENCY
+                                                                                                                                                                                              Energy efficiency is optimized by preconditioning the outside
+ADVERSE EFFECTS OF DEFICIENT IAQ                                                                                                                                                              air coming in with the otherwise-wasted sensible and
+Deficient IAQ has numerous adverse effects on health, cognitive function, productivity and general wellbeing.                                                                                 latent energy of the exhaust air going out. This exchange of
+                                                                                                                                                                                              energy moderates temperatures and moisture, decreases HVAC
+   Health Problems: Acute allergies, headaches, coughs, asthma, skin irritations and breathing difficulties, as well as                                                                       equipment needs, drives operational efficiencies and conserves energy.
+   chronic illnesses such as cancer, liver disease, kidney damage and nervous-system failure.                                                                                                 REDUCING HVAC LOADS
+                                                                                                                                                                                              RenewAire technology reduces HVAC loads during both winter and summer. The size of the HVAC equipment (furnace and
+   Cognitive Impairment: Studies by the Harvard School of Public Health and the Lawrence Berkeley National Laboratory                                                                         air conditioner) can be decreased. This ensures efficient operation and keeps both energy use and operating costs low while
+   found that carbon dioxide (CO2)—a constituent of exhaled breath—negatively impacted thinking and decision-making                                                                           maintaining high-level IAQ.
+   at levels commonly found inside homes and buildings.                                                                                                                                       MINIMIZING ENVIRONMENTAL IMPACT
+                                                                                                                                                                                              The combination of optimized energy efficiency and reduced HVAC loads conserves resources. Further, our Madison, WI
+   Reduced productivity: Enhanced IAQ could save up to $200 billion in worker performance and $58 billion in lost                                                                             plant is 100% powered by renewable wind energy. It is also one of the few buildings worldwide to be LEED, Green Globes
+   sick time4.                                                                                                                                                                                and ENERGY STAR certified. This commitment to sustainable manufacturing minimizes our overall production and distribution
+                                                                                                                                                                                              environmental footprint.
+1 “Indoor Air Quality,” National Safety Council, http://www.nsc.org/NSCDocuments_Advocacy/Fact%20Sheets/Indoor-Air-Quality.pdf.
+                                                                                                                                                                                              THE RENEWAIRE DIFFERENCE
+2 “ Frequently Asked Questions about Improved Academic Performance,” U.S. Environmental Protection Agency (EPA), https://www.epa.gov/iaq-schools/frequently-asked-questions-about-improved-
+ academic-performance.                                                                                                                                                                        For over 30 years, RenewAire has been a leader in enhancing IAQ in commercial and residential buildings. Our ERVs are
+                                                                                                                                                                                              competitively priced, simple and easy to use and maintain, have a quick payback, return on investment, and due to
+3 S ource of data and statements: Int. J. Environ. Res. Public Health 2015, 12 (11), 14709-14722.                                                                                            unparalleled reliability derived from innovative design practices, expert workmanship and Quick Response Manufacturing
+                                                                                                                                                                                              (QRM), we provide an industry-leading warranty. In 2010, RenewAire joined the Soler & Palau (S&P) Ventilation Group, providing
+4 Greg Kats, “The Costs and Financial Benefits of Green Buildings,” USGBC, October 2003, https://www.usgbc.org/Docs/News/News477.pdf. Data sourced from this statement on page 10:           access to the latest in energy-efficient air-moving technologies.
+  “A Lawrence Berkeley National Laboratory study found that U.S. businesses could save as much as $58 billion in lost sick time and an additional $200 billion in worker
+  performance if improvements were made to indoor air quality.”                                                                                                                                                                                                                                           3
+
+2
+RENEWAIRE ERVs
+
+              VENTILATION SOLUTIONS FOR EVERY APPLICATION
+
+                                                          SL SERIES
+
+                                                                                u Residential ERVs—four-duct design
+                                                                                u Indoor
+                                                                                u 51-76 CFM continuous mode
+                                                                                u 76-94 CFM boost mode
+
+                                                          BR SERIES
+
+                                                                                u Residential ERVs—two-duct design
+                                                                                u Indoor
+                                                                                u 40-140 CFM
+
+                                                          EV SERIES
+
+                                                                   u R esidential and light commercial
+
+                                                                                    ERVs—four-duct design
+                                                                                u Indoor/outdoor (varies by model)
+                                                                                u 40-540 CFM
+
+                                                          HE SERIES
+
+                                                                   u C ommercial ERVs—packaged
+
+                                                                                    solutions
+
+                                                                   u Indoor/outdoor
+                                                                   u 2 50-7,950 CFM
+
+                                                          LE SERIES
+
+                                                                   u C ommercial ERVs—large capacity
+                                                                   u Indoor/outdoor
+                                                                   u 1 ,500-11,000 CFM
+
+FOR CERTIFICATION DETAILS SEE UNIT SUBMITTALS ON RENEWAIRE.COM
+
+                                                                                                                                                                                                                       4
+RENEWAIRE ERVs
+
+              VENTILATION SOLUTIONS FOR EVERY APPLICATION
+
+                                                            CA SERIES
+
+                                                                                   u Applied ERVs—modular cabinets
+                                                                                   u Indoor/outdoor
+                                                                                   u 500-4,400 CFM
+                                                                                   u Stackable to 20,000 CFM
+
+                                                            PA SERIES
+
+                                                                                   u Applied ERVs—modular panels
+                                                                                   u Indoor
+                                                                                   u 1500-unlimited CFM
+
+RD SERIES
+
+u C ommercial—Dedicated Outdoor
+
+   Air System (DOAS)
+u Indoor/outdoor
+u 500-4,250 CFM
+
+DN SERIES
+
+u C ommercial—Dedicated Outdoor
+
+   Air System (DOAS)
+u Indoor/outdoor
+u 375-4,950 CFM
+
+OPTIONS & ACCESSORIES
+
+u ECM motors   u Bypass economizers
+
+u Variable frequency drives u Electric duct heaters
+
+u Motorized isolation dampers u Filter alarms
+
+u Combo curbs
+
+FOR CERTIFICATION DETAILS SEE UNIT SUBMITTALS ON RENEWAIRE.COM
+
+5
+            VENTILATION SOLUTIONS FOR EVERY APPLICATION
+
+SUSTAINABLE
+
+INDOOR AIR QUALITY
+
+AHU      ERV                           AHU                              ERV  AHU  ERV
+
+      7                     1                                                                                                                                                   ERV
+                                    4
+      7                                                                                                                          1
+5                  6                                                    4
+
+              AHU  ERV                                                                                                                                                 AHU
+
+                        3                                                         2
+                                                                                                                                              7
+
+                                                                                                       8
+
+                                                                                                                                            2
+                                                                                              6
+
+                                                                                                                                              6
+
+     REDUCE INDOOR AIR CONTAMINANTS
+
+1. HUMIDITY                                                             5. TOBACCO SMOKE
+      Exhaled breath, water sources (faucets, showers, leaks, floods)         Smoking areas close to building entrance
+
+2. CARBON DIOXIDE                                                       6. PHTHALATES
+      Constituent of exhaled breath                                           Off-gassed from adhesives, vinyl flooring, wood finishes, plastic
+                                                                              plumbing pipes, other building materials
+3. FORMALDEHYDE
+      Off-gassed from adhesives, fabric treatments, stains, varnishes   7. VOCs, TOXIC GASES, VAPORS
+                                                                              Off-gassed from furniture, carpets, paints, cleaners, solvents, glues,
+4. ODORS                                                                      building materials
+      Bathrooms, kitchens, dry-erase markers, occupant odors (perfume,
+      soap/shampoo residue, clothing detergent, general odors), pets    8. OZONE
+                                                                              Off-gassed from copiers, electrostatic air cleaners,
+                                                                              other office equipment
+
+                                                                                       RenewAire.com
+                                                                                       800.627.4499
+
+                                                                                                LIT074_03 (12/18)
+